Loading...
HomeMy WebLinkAboutNC0055905_Draft Permit_20201110 ROY COOPER Governor MICHAEL S.REGAN Secretory S.DANIEL SMITH NORTH CAROLINA Director Environmental Quality November 10,2020 Arnold Andresen Utilities Chairman Waterford Place Property Owners Association 10 Lakeside Court Brevard,NC 28712 Subject: Draft NPDES Permit NC0055905 j Waterford Place WWTP Grade I Biological WPCS Transylvania County Dear Mr. Andresen: Enclosed with this letter is a copy of the Draft NPDES permit renewal for your facility. Please review this draft carefully to ensure thorough understanding of the requirements and conditions it contains. We understand from your renewal application that there have been no significant changes to the treatment system. There are a few changes in the draft from the existing permit. These changes are summarized below. • Regulatory Citations—Language has been added where necessary in the permit to provide regulatory citations for permit requirements. • Electronic Reporting—Permit language has been updated to be consistent with the finalization of federal requirements for electronic reporting. The NPDES standard conditions(Parts II, III,and IV)that are a part of the permit are not included in this draft document(cover,map,and Part I).The conditions are the same as in your current permit.The latest version of the standard conditions is available at https://bit.ly/2BZ4xxx and can be viewed online or downloaded as a PDF file. Concurrent with this notification the Division is publishing a notice in a newspaper having general circulation in the Transylvania County area soliciting public comments on this draft permit. Please provide any written comments you may have to me no later than 30 days after receipt of this draft permit. Q North of n Quality I s ���/// 512 North SalisburyCarolinaDepartment Street 11617 Mall Enviro mental Service Center I Raleigh,Diviion Northof CarolinaWaterResources 27699-1617 �*■++ �++ � /'d 919.707.9000 Arnold Andresen Page 2 Following the 30-day public comment period,the Division will review all pertinent comments and take appropriate action prior to issuing a final permit.If you have questions concerning this draft permit, please call me at(919)707-3629 or contact me by email at bradley.bennett@ncdenr.gov. Sincerely, Bradley Bennett Compliance and Expedited Permitting Unit cc: NPDES Files-electronic Asheville Regional Office/Water Quality—electronic Operator Certification Program/Maureen Kinney—electronic Draft NPDES Permit NC0055905 L STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION OF WATER RESOURCES PERMIT TO DISCHARGE WASTEWATER UNDER THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) In compliance with the provisions of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission,and the Federal Water Pollution Control Act,as amended, the Waterford Place Property Owners Association is hereby authorized to discharge wastewater from a facility located at the Waterford Place WWTP Music Camp Rd, Brevard, NC Transylvania County to receiving waters designated as Hunts Branch a class C waterbody in subbasin 04-03-01 of the French Broad River Basin in accordance with effluent limitations,monitoring requirements,and other conditions set forth in Parts I, II,III and IV hereof This permit shall become effective This permit and authorization to discharge shall expire at midnight on September 30,2025. If the permittee intends to continue to discharge at the facility beyond the term of this permit, a renewal application must be submitted no later than April 3,2025(180 days before the expiration of this permit). Signed this day S. Daniel Smith,Director Division of Water Resource s By Authority of the Environmental Management Commission Page 1 of 8 Draft NPDES Permit NC0055905 SUPPLEMENT TO PERMIT COVER SHEET All previous NPDES Permits issued to this facility,whether for operation or discharge are hereby revoked,and as of this issuance,any previously issued permit bearing this number is no longer effective.Therefore,the exclusive authority to operate and discharge from this facility arises under the permit conditions,requirements,terms,and provisions included herein. The Waterford Place Property Owners Association is hereby authorized to: 1. Continue to operate an existing 0.023 MGD wastewater treatment system that includes the following components: • 70 individual septic tanks • Influent lift station with duplex pumps,dual alarms and emergency generator • Dosing tank with alternating siphons • Dual surface sand filters,dosed alternately • Tablet chlorinator with 1000-gallon contact chamber • Tablet dechlorination • Effluent(concrete step)cascade aeration This facility is located near Brevard at the Waterford Place WWTP off Music Camp Road in Transylvania County. 2. After receiving an Authorization to Construct(AtC) permit from the Division, construct and operate a 0.046 MGD wastewater treatment system. 3. Discharge from said treatment works at the location specified on the attached map into Hunts Branch,currently classified C waters in hydrologic unit 060101050203 of the French Broad River Basin. Page 2 of 8 Draft NPDES Permit NC0055905 Part I A. (1) EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS [0.023 MGD] [15A NCAC 02B.0400 et seq., 15A NCAC 02B.0500 et seq.] Grade I Biological Water Pollution Control System [15A NCAC 08G.0302] During the period beginning on the effective date of the permit and lasting until expansion above 0.023 MGD (or until expiration),the Permittee is authorized to discharge from outfall 001. Such discharges shall be limited and monitored' by the Permittee as specified below: EFFLUENT LIMITS MONITORING REQUIREMENTS CHARACTERISTICS Monthly Daily Measurement Sample Type Sample [eDMR Codes] Average Maximum Frequency Location Flow(MGD) 50050 0.023 Weekly Instantaneous Influent or Effluent BOD,5-day(20°C) C0310 30.0 45.0 2/Month Grab Effluent Total Suspended Solids(mg/L) C0530 30.0 45.0 2/Month Grab Effluent NH3 as N(mg/L) C0610 2/Month Grab Effluent Dissolved Oxygen(mg/L) 00300 Daily average>6.0 Weekly Grab Effluent, Fecal Coliform[geometric 31616 200/100 400/100 2/Month Grab Effluent mean](mL) Total Residual Chlorine(TRC) 50060 28 Weekly Grab Effluent (µg/1-)2 Temperature(°C) 00010 Weekly Grab Effluent, pH(su) 00400 >6.0 and<9.0 2/Month Grab Effluent Footnotes: 1. The permittee shall submit discharge monitoring reports electronically using the NC DWR's eDMR system[see A.(3)]. 2. The Division shall consider all effluent TRC values reported below 50 µg/L to be in compliance with the permit. However,the Permittee shall continue to record and submit all values reported by North Carolina certified test methods (including field certified),even if these values fall below 50 µg/L. THERE SHALL BE NO DISCHARGE OF FLOATING SOLIDS OR VISIBLE FOAM IN OTHER THAN TRACE AMOUNTS. Page 3 of 8 Draft NPDES Permit NC0055905 A. (2) EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS [0.046 MGD] [15A NCAC 02B.0400 et seq., 15A NCAC 02B.0500 et seq.] Grade I Biological Water Pollution Control System [15A NCAC 08G.0302] During the period beginning after expansion above 0.023 MGD and lasting until expiration, the Permittee is authorized to discharge from outfall 001. Such discharges shall be limited and monitored' by the Permittee as specified below: EFFLUENT CHARACTERISTICS LIMITS MONITORING REQUIREMENTS Monthly Daily Measurement Sample Type Sample feDMR Codes] Average Maximum Frequency Location Flow(MGD) 50050 0.046 Weekly Instantaneous Influent or Effluent BOD,5-day(20°C)(mg/L) C0310 30.0 45.0 Weekly Grab Effluent Total Suspended Solids C0530 30.0 45.0 Weekly Grab Effluent (mg/L) NH3 as N(mg/L) Summer2 C0610 2.0 10.0 2/Month Grab Effluent NH3 as N(mg/L) Winter2 C0610 4.0 20.0 2/Month Grab Effluent Dissolved Oxygen(mg/L) 00300 Daily average>6.0 Weekly Grab Effluent Fecal Coliform(geometric 31616 200/ 100 400/ 100 2/Month Grab Effluent mean)(mL) Total Residual Chlorine 50060 28 2/Week Grab Effluent (TRC)3 (µg/L) Temperature(°C) 00010 Weekly Grab Effluent pH(su) 00400 >6.0 and<9.0 2/Month Grab Effluent Footnotes: 1. The permittee shall submit discharge monitoring reports electronically using the NC DWR's eDMR system[see A.(3)]. 2. Summer—April through October; Winter=November through March 3. The Division shall consider all effluent TRC values reported below 50 µg/L to be in compliance with the permit. However,the Permittee shall continue to record and submit all values reported by North Carolina certified test methods (including field certified),even if these values fall below 50 µg/L. THERE SHALL BE NO DISCHARGE OF FLOATING SOLIDS OR VISIBLE FOAM IN OTHER THAN TRACE AMOUNTS. A. (3) ELECTRONIC REPORTING OF DISCHARGE MONITORING REPORTS [NCGS 143-215.1 (b)] Federal regulations require electronic submittal of all discharge monitoring reports(DMRs) and program reports.The final NPDES Electronic Reporting Rule was adopted and became effective on December 21, 2015. NOTE: This special condition supplements or supersedes the following sections within Part II of this permit(Standard Conditions for NPDES Permits): Page 4 of 8 Draft NPDES Permit NC0055905 • Section B. (11.) Signatory Requirements • Section D. (2.) Reporting • Section D. (6.) Records Retention • Section E. (5.) Monitoring Reports 1. Reporting Requirements [Supersedes Section D. (2.) and Section E. (5.) (a)I The permittee shall report discharge monitoring data electronically using the NC DWR's Electronic Discharge Monitoring Report(eDMR) internet application. Monitoring results obtained during the previous month(s) shall be summarized for each month and submitted electronically using eDMR. The eDMR system allows permitted facilities to enter monitoring data and submit DMRs electronically using the internet. The eDMR system may be accessed at: https://deq.nc.gov/about/divisions/water-resources/edmr. If a permittee is unable to use the eDMR system due to a demonstrated hardship or due to the facility being physically located in an area where less than 10 percent of the households have broadband access,then a temporary waiver from the NPDES electronic reporting requirements may be granted and discharge monitoring data may be submitted on paper DMR forms(MR 1, 1.1,2, 3) or alternative forms approved by the Director. Duplicate signed copies shall be submitted to the following address: NC DEQ/Division of Water Resources/Water Quality Permitting Section ATTENTION: Central Files 1617 Mail Service Center Raleigh,North Carolina 27699-1617 See"How to Request a Waiver from Electronic Reporting"section below. Regardless of the submission method,the first DMR is due on the last day of the month following the issuance of the permit or in the case of a new facility,on the last day of the month following the commencement of discharge. Starting on December 21,2025 the permittee must electronically report the following compliance monitoring data and reports,when applicable: • Sewer Overflow/Bypass Event Reports; • Pretreatment Program Annual Reports; and • Clean Water Act(CWA) Section 316(b)Annual Reports. The permittee may seek an electronic reporting waiver from the Division(see"How to Request a Waiver from Electronic Reporting"section below). Page 5 of 8 P Draft NPDES Permit NC0055905 2. Electronic Submissions In accordance with 40 CFR 122.41(1)(9),the permittee must identify the initial recipient at the time of each electronic submission. The permittee should use the EPA's website resources to identify the initial recipient for the electronic submission. Initial recipient of electronic NPDES information from NPDES-regulated facilities means the entity (EPA or the state authorized by EPA to implement the NPDES program)that is the designated entity for receiving electronic NPDES data[see 40 CFR 127.2(b)]. EPA plans to establish a website that will also link to the appropriate electronic reporting tool for each type of electronic submission and for each state. Instructions on how to access and use the appropriate electronic reporting tool will be available as well. Information on EPA's NPDES Electronic Reporting Rule is found at: https://www.federalregister.gov/documents/2015/10/22/2015- 24954/national-pollutant-discharge-elimination-system-npdes-electronic-reporting-rule Electronic submissions must start by the dates listed in the"Reporting Requirements"section above. 3. How to Request a Waiver from Electronic Reporting The permittee may seek a temporary electronic reporting waiver from the Division. To obtain an electronic reporting waiver,a permittee must first submit an electronic reporting waiver request to the Division. Requests for temporary electronic reporting waivers must be submitted in writing to the Division for written approval at least sixty(60)days prior to the date the facility would be required under this permit to begin submitting monitoring data and reports. The duration of a temporary waiver shall not exceed 5 years and shall thereupon expire. At such time,monitoring data and reports shall be submitted electronically to the Division unless the permittee re-applies for and is granted a new temporary electronic reporting waiver by the Division. Approved electronic reporting waivers are not transferrable. Only permittees with an approved reporting waiver request may submit monitoring data and reports on paper to the Division for the period that the approved reporting waiver request is effective. Information on eDMR and the application for a temporary electronic reporting waiver are found on the following web page: http://deq.nc.gov/about/divisions/water-resources/edmr 4. Sianatory Requirements [Supplements Section B. (11.) (b)and Supersedes Section B. (11.) (d)1 All eDMRs submitted to the permit issuing authority shall be signed by a person described in Part II, Section B. (11.)(a)or by a duly authorized representative of that person as described in Part II, Section B. (11.)(b). A person,and not a position,must be delegated signatory authority for eDMR reporting purposes. For eDMR submissions,the person signing and submitting the DMR must obtain an eDMR user account and login credentials to access the eDMR system. For more information on North Carolina's eDMR system,registering for eDMR and obtaining an eDMR user account,please visit the following web page: Page 6 of 8 Draft NPDES Permit NC0055905 http://deq.nc.gov/about/divisions/water-resources/edmr Certification. Any person submitting an electronic DMR using the state's eDMR system shall make the following certification[40 CFR 122.22]. NO OTHER STATEMENTS OF CERTIFICATION WILL BE ACCEPTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." 5. Records Retention [Supplements Section D. (6.)1 The permittee shall retain records of all Discharge Monitoring Reports, including eDMR submissions. These records or copies shall be maintained for a period of at least 3 years from the date of the report. This period may be extended by request of the Director at any time [40 CFR 122.41]. Page 7 of 8 14 v t- . o . . . ,,,, .410, ie,--zi: Ah--! . . :IC! i.- -\ ..11.01 • 1111t11101 .... :ts...- 4 NVIIVIIIMMI mg.. . lir: Atr) , •Iiii Natoli .1*11,41441.v`,.. .. . . r'*.44/044•44 ''' 14 16 `••••4'*IIN'`› t.y, -7444 i• ,, • • • • -.c .---• , 2.-.,-, . wie . • . -- • 1 • NO .f • t• •• � • • r• • St 19 •� • •• • �• 1r4 L • /// it •• :+1 • . • . . Mtl t: s OUTFALL o �r, '> !r') •• • •-• ••• ' _ • , _ . , • to !a'- Y a< Inds!11Z`j,........, . - k, •. • - •�r�}__ -* '•,, 001 t •�,. i• � .•- •• 4c, ,........„..., . s ., . Allft 1 ••• 1:°""?.. ----4 -41.--. ."../.......\"---.N.:.. 7 . '..' '.* * Ilit, ,.. . • ..?1,1• ........":„. _ a ir Probart Street -4) • • • • • P, R t fili •` • _ •fe‘ ' ‘1 b AN ' . o j •. •� , • • , 11 � ' �; i1 • .• ♦ • •_"•-;,....,.//46,1/4,, . .4, ..•may• •• • p t /' QitID-7;: 44,„$, i i 1 1 1.110 "‘A '411611 —'13:Airlyhr. :3 ' '2°' ;•. , 717' '. 4‘. :. .... (494 . )1 Valley Road kl'` - fl,�M ,hmney• i„..• �• • ol,• • • •. • • i cs. % , ir • cow •._• ,. , •Silr . ii , to -, ... it • • ,. .:sc i (",. ,,, .„,. k 1 , _ .. • ..4 /„.i: • . . / : ..... „.•,,,r),44rs 11), #-**. \ i .4.. , `• 4, ;Ay A• • !. IIP 1 •••19..r. . ---- ••0 1 , ‘0.1\„, • • : •• _• 4 , , /1 4.1. ,., I , A ,• , „ • j _ •r�� • '- V . ,ire' .,. I• • I. _ •_ .1 It' • . • : . kll rill. Waterford Place Property Owners Assoc. A Facility 1A/atarfnrrl Plara 1A/1A/TP Location Receiving Stream: Hunts Branch Stream Class: C (not to scale) River Basin: Transylvania Sub-Basin: 04-03-01 Latitude: 35°14'20" Longitude: 82°45'00" Stream Segment 6-28-2-2 HUC#: 060101050203 �cmin NPDES Permit: NC0055905 Grid/Quad: G8NW(Brevard)� ) Transylvania County Page 8 of 8