Loading...
HomeMy WebLinkAboutNC0050075_CSI_pics_20130116 United States Environmental Protection Agency Form Approved. EPA Washington,D.C.20460 OMB No.2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 INI 2 15I 31 NCO050075 111 121 13/01/16 117 18I S I 19I S I 201 I Remarks 211 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 116 Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA ---------------------------Reserved---------------------- 67 I 169 70131 711 I 721 N I 73I I 174 751 I I I I I I 1 80 Section B: Facility Data I_I_I Name and Location of Facility Inspected(For Industrial Users discharging to POTW,also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 11:30 AM 13/01/16 10/03/01 Collettsville Elementary School 4690 Collettsville School Exit Time/Date Permit Expiration Date Collettsville NC 28611 12:05 PM 13/01/16 15/02/28 Name(s)of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Name,Address of Responsible Official/Title/Phone and Fax Number Contacted Jeff Church,1914 Hickory Blvd Lenoir NC 28645//828-728-8407/8287280012 Yes Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit 0 Flow Measurement Operations&Maintenance 0 Records/Reports Self-Monitoring Program 0 Facility Site Review Effluent/Receiving Waters Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s)and Signature(s)of Inspector(s) Agency/Office/Phone and Fax Numbers Date Linda S Wiggs ARO WQ//828-296-4500 Ext.4653/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3(Rev 9-94)Previous editions are obsolete. Page# 1 NPDES yr/mo/day Inspection Type 1 3 I NC0050075 111 12, 13/01/16 117 18 I S Section D: Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary) Effluent samples were obtained. pH 7.1 s.u., BOD 9.3 mg/I, TSS 13 mg/I. No concerns with WWTP or receiving waters were noted during the inspection. Page# 2 Permit: NCO050075 Owner-Facility: Collettsville Elementary School Inspection Date: 01/16/2013 Inspection Type: Compliance Sampling Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? ■ 0 0 0 Does the facility analyze process control parameters,for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge ■ Judge, and other that are applicable? Comment: Pumps are checked — 3 months for maintenance problems. Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new application? 0 ❑ ■ ❑ Is the facility as described in the permit? ■ ❑ 0 0 #Are there any special conditions for the permit? ❑ ❑ ■ Is access to the plant site restricted to the general public? ■ ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? ■ fl fl fl Comment: Bar Screens Yes No NA NE Type of bar screen a.Manual ■ b.Mechanical fl Are the bars adequately screening debris? ■ 11011 Is the screen free of excessive debris? ■ 0 El 0 Is disposal of screening in compliance? ■ 11011 Is the unit in good condition? ■ ❑ ❑ ❑ Comment: Aeration Basins Yes No NA NE Mode of operation Ext.Air Type of aeration system Diffused Is the basin free of dead spots? ■ Are surface aerators and mixers operational? ❑ ❑ ■ ❑ Are the diffusers operational? ■ Is the foam the proper color for the treatment process? ■ ❑ 0 ❑ Does the foam cover less than 25%of the basin's surface? ■ ❑ 0 ❑ Is the DO level acceptable? ■ Is the DO level acceptable?(1.0 to 3.0 mg/1) ■ ❑ 0 ❑ Page# 3 Permit: NCO050075 Owner-Facility: Collettsville Elementary School Inspection Date: 01/16/2013 Inspection Type: Compliance Sampling Aeration Basins Yes No NA NE Comment: DO between 0.6-0.8 mg/I Primary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? ■ rl fl rl Is the site free of excessive buildup of solids in center well of circular clarifier? fl ❑ ■ Are weirs level? n n n ■ Is the site free of weir blockage? ■ Is the site free of evidence of short-circuiting? ■ ❑ ❑ ❑ Is scum removal adequate? ■ ❑ ❑ ❑ Is the site free of excessive floating sludge? ■ ❑ ❑ ❑ Is the drive unit operational? rl ❑ ■ Is the sludge blanket level acceptable? ■ Is the sludge blanket level acceptable?(Approximately'/4 of the sidewall depth) ■ ❑ rl ❑ Comment: The blanket was getting high. ORC believed it was due to pH adjustments recently made. Sludge is brought to Lower Crk WWTP when removed. Page# 4 • d I ' - _ - - � � � �h � ' - III ►� � L P ! ► I)Il � li � ! ►� : `� �" � ' '� � ' ' � '� ram, I I ' iAI1 � l ri v n x i 1 / 16 / 2013 11 : 23 LWf � Y i I � t r i i A _ a rf 1� ' . .c. .C.•-6 ('lr r r > �Id � fi . .. • .f