Loading...
HomeMy WebLinkAboutNCG020007_CEI_20201106ROY COOPER Governor MICHAEL S. REGAN Secretary BRIAN WRENN Director Covia Holdings Corporation Attn: Douglas S. Losee, VP Environmental 2829 Technology Forest Blvd, Suite 100 The Woodlands, TX 77381 NORTH CAROLINA Environmental Quality November 6, 2020 Subject: COMPLIANCE EVALUATION INSPECTION NPDES Stormwater General Permit NCG020000 Covia Holdings Corporation Marston Plant, Certificate of Coverage NCG020007 Richmond County Dear Mr. Losee: On November 4, 2020, a site inspection was conducted for the Marston Plant located at 541 Cognac Road, Marston, Richmond County, North Carolina. A copy of the Compliance Inspection Report is enclosed for your review. Mr. Kenneth Akins, QC/Safety/Environmental Supervisor, Mr. Matt Wilkins, Operations Manager, and Mr. David Hayes, Plant Manager, were also present during the inspection and their time and assistance is greatly appreciated. The site visit and file review revealed that the subject facility is covered by NPDES Stormwater General Permit NCG020000 under Certificate of Coverage NCG020007. Permit coverage authorizes the discharge of stormwater and/or wastewater, as approved in the original permit/application or subsequent permit modification, from the facility to receiving waters designated as Clay Branch, a class C water in the Lumber River Basin. It should be noted, however, that based on the facility's location, discharges from certain areas of the facility located west of Cognac Road would likely be to receiving waters designated as Mill Creek (McLeods Lake), a class C water in the Lumber River Basin. As a result of the inspection, the facility was found to be in.compliance with the conditions of the NCG020000 permit. Please refer to the enclosed Compliance Inspection Report for additional comments and observations made during the inspection. Please be advised that violations of the NPDES Stormwater General Permit are subject to a civil penalty assessment of up to $25,000 per day for each violation. If you or your staff have any questions, comments, or needs assistance with understanding any aspect of your permit, please contact me at (910) 433-3394 or via e-mail at mike.lawyer@ncdenr.gov. Sincerely, c Michael Lawyer, CPSWQ Environmental Program Consultant Division of Energy, Mineral and Land Resources Enclosure: Compliance Inspection Report ec: Kenneth Akins, QC/Safety/Environmental Supervisor —Covia Holdings Corporation, Marston Plant Matt Wilkins, Operations Manager — Covia Holdings Corporation, Marston Plant David Hayes, Plant Manager — Covia Holdings Corporation, Marston Plant Michelle Maxson, Environmental Specialist — Covia Holdings Corporation cc: FRO — DEMLR, Stormwater Files ,/�_ North Carolina Department of Environmental Quality I Division of Energy, Mineral and Land Resources ...+�" �� E Q> Fayetteville Regional Office ) 225 Green Street, Suite 7141 Fayetteville, North Carolina 28301 NS:R7iIC1FlOI..:Nti '' uaaeranent m �nracrnwma� ave`N� 910.433.3300 Compliance Inspection Report Permit: NCG020007 Effective: 10/01/20 Expiration: 05/01/21 Owner: Covia Holdings Corporation SOC: Effective: Expiration: Facility: Marston Plant County: Richmond 541 Cognac Rd Region: Fayetteville Marston NC 28363 Contact Person: Michele Maxson Title: Environmental Specialist Phone: 980-495-2384 Directions to Facility: System Classifications: Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Representative(s): On -site representative Kenneth Akins 910-582-4816 On -site representative David Hayes 910-582-4816 On -site representative Matt Wilkins 910-582-4816 Related Permits: Inspection Date: 11/04/2020 Entry Time 09:55AM Exit Time: 12:40PM Primary Inspector: Mike Lawyer Phone: 910-433-3394 Secondary Inspector(s): Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Mining Activities Stormwater Discharge COC Facility Status: Compliant ❑ Not Compliant Question Areas: Storm Water (See attachment summary) Page 1 of 3 Permit: NCG020007 Owner - Facility: Covia Holdings Corporation Inspection Date: 11/04/2020 Inspection Type: Compliance Evaluation Reason for Visit: Routine Inspection Summary: Inspection for compliance with the conditions of the NCG020000 permit conducted in conjunction with an inspection for compliance with the facility's mining permit (77-06). Observations were made of the mine site including the settling/recirculating ponds, excavation areas, waste sand disposal areas and ASTs with appropriate secondary containment. Reviewed the facility's Stormwater Pollution Prevention Plan (SPPP) and available monitoring records since the previous inspection conducted on August 28, 2018. The SPPP appears to contain all required components as well as documentation associated with the annual review and update requirements. Monitoring records indicate a wastewater discharge monitoring event in September of 2018, no discharges in 2019, and a wastewater discharge monitoring event in February of 2020. Both of the wastewater discharge monitoring events resulted from the facility pumping water out of one of their settling/recirculating ponds in preparation for Hurricane Florence (2018) and in response to high water levels due to intense storm event (2020). There were also unanticipated bypasses/discharge events in September 2018 and February 2020, which were appropriately reported and addressed. Page 2 of 3 Permit: NCG020007 Owner - Facility: Covia Holdings Corporation Inspection Date: 11/04/2020 Inspection Type: Compliance Evaluation Reason for visit: Routine Stormwater Pollution Prevention Plan Yes No NA NE Does the site have a Stormwater Pollution Prevention Plan? E ❑ ❑ ❑ # Does the Plan include a General Location (USGS) map? 0 ❑ ❑ ❑ # Does the Plan include a "Narrative Description of Practices"? 0 ❑ ❑ ❑ # Does the Plan include a detailed site map including outfall locations and drainage areas? 0 ❑ ❑ ❑ # Does the Plan include a list of significant spills occurring during the past 3 years? 0 ❑ ❑ ❑ # Has the facility evaluated feasible alternatives to current practices? ❑ ❑ E ❑ # Does the facility provide all necessary secondary containment? 0 ❑ ❑ ❑ # Does the Plan include a BMP summary? 0 ❑ ❑ ❑ # Does the Plan include a Spill Prevention and Response Plan (SPRP)? 0 ❑ ❑ ❑ # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? 0 ❑ ❑ ❑ # Does the facility provide and document Employee Training? 0 ❑ ❑ ❑ # Does the Plan include a list of Responsible Party(s)? 0 ❑ ❑ ❑ # Is the Plan reviewed and updated annually? 0 ❑ ❑ ❑ # Does the Plan include a Stormwater Facility Inspection Program? 0 ❑ ❑ ❑ Has the Stormwater Pollution Prevention Plan been implemented? E ❑ ❑ ❑ Comment: Qualitative Monitorinq Yes No NA NE Has the facility conducted its Qualitative Monitoring semi-annually? ❑ ❑ 0 ❑ Comment: Facility has no distinct stormwater discharge outfalls. Analytical Monitoring Yes No NA NE Has the facility conducted its Analytical monitoring? 0 ❑ ❑ ❑ # Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? ❑ ❑ 0 ❑ Comment: Permit and Outfalls Yes No NA NE # Is a copy of the Permit and the Certificate of Coverage available at the site? 0 ❑ ❑ ❑ # Were all outfalls observed during the inspection? ❑ ❑ ❑ # If the facility has representative outfall status, is it properly documented by the Division? ❑ ❑ E ❑ # Has the facility evaluated all illicit (non stormwater) discharges? ❑ ❑ 0 ❑ Comment: Page 3 of 3