Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SW3201003_SAND FILTER CALCS_20201103
SAND FILTER CALCULATIONS references: NCDENR Stormwater BMP Manual Chapter 11 Date : 7-Oct-20 PROJECT AUTO FINANCE & CAR CARE CENTER SAND FILTER 1 Base Data 730 Windsor Oak Ct Charlotte, NC 28241 704-556-1990 YARBROUGH-WILLIAMS & HOULE, INC. Planning • Surveying - Engineering Site Area Post = Total Drainage Area (A) = Site Area Pre = Total Drainage Area (A) = Measured Impervious Area - Hydrologic Data Pre - CN 2.62 ac 4.86 ac 4.86 ac 53.85% Acreage Land Use Soil Type Hydrologic Group CN wei hted CN 0.05 Ex Pvmt 98 1.01 4.81 Woods ScA C 70 69.28 0.00 0.00 4.86 Post - CN CNpre 70 Acrea a Land Use Soil T e H drolo is roup CN k4aiahted CN 2.62 Bld /Pvt/SW 98 52.77 2.24 Grass ScA C 74 34.15 0.00 0.00 4.86 Pre CN 70 Post 87 CNp..t 87 Steps 1, 2 Determine if the development site and conditions are appropriate for the use of a Sand Filter pond and consider any site -specific design considerations. Step 3 Compute Water Quality Volume (WQv) Compute Runoff Coefficient, Rv, using (Schueler's Method) Equation 3.1 Rv = 0.05 + 0.009 (1) 1 = percent impervious over basin area = Total Rainfall amount (P) = Rv = 0.534618916 RD = 1 Compute Water Quality Volume, WQv, using Equation 3.2 WQv = 1.ORvA/12 = 0.22 ac-ft or Convert Water Quality Volume, WQv to inches of runoff using Equation 3.3 WQv = 1.0(Rv) = 0.53 in 53.8 % �in Design Volume 9432 cf e`' �`�alH,ereeonta®'og',0' '9 7537 logl{®Y�dd id 411984 :9.��%" 11` 6��0 Compute Site Hydrologic Input Parameters Using SCS hydrologic procedures and/or computer models the following data can be determined for the example development site. Step 4 Summary of Hydrocad Input and Output HYDROLOGIC INPUT DATA Condition Area ac CN tc hours tc min Pre-dev 4.86 70 0.08 5 Post dev 4.86 87 0.08 5 Results of Preliminary Hydrologic Calculations (From Computer Model Results Using SCS Hydrologic Procedures) Condition 1 YR Q2- ear Q10- ear Runoff cfs cfs cfs Pre-Dev 3.22 3.27 11.12 w/ out controls Post Dev 10.04 22.64 23.27 w/ controls Post Dev 0.47 0.73 9.58 POST MODIFIED CN Step 5 Compute Water Quality Peak Flow (WQp) using modified CN (adjusted) value Compute modified SCS curve number, CN, using Equation 3.4 CN mod -post = 1000/[10 + 5P + 10WQv - 10(WQv2 + 1.25 WQVP)0.5] CN mod -post = 95 Compute WQp using SCS the hydrograph procedure documented in the CMSWDM using Hydrocad hydrologic model. A 1-inch, 6-hour balanced storm event is required. See Hydrocad Report WQp = 6.48 cfs Step 5 Compute Sedimentation Chamber Minimum Surface Area Per Section 11.3.5 NCDENR Stormwater BMP Manual Also Min As (ft2� _ [240 * Rv * AD) * Ru (ft) = 623.58 sf As provided = 1850.0 sf Forebay Chamber Storage -Elevation Data Elevation Area sf Area ac Ht ft Inc. Vol ac-ft Acc. Vol ac-ft Acc. Vol cf 685 1000.0 0.023 0.0 0.00 0.00 0.00 686 1400.0 0.032 1.0 0.03 0.03 1200.00 687 1850.0 0.042 2.0 1.00 1.03 44760.00 Step 6 Compute Sand Filter Area to Treat Water Quality Volume Af = (WQv)(df)/[(k)(hf+df)(tf)] where: Af = surface area of filter bed (ft2) WQv = Treatment Water Quality Volume (cf) 9431.64 cf df = filter bed depth (ft) 1.50 k = coefficient of permeability of filter media (ft/day) 3.5 hA = average height of water above filter bed (ft) 0.96 tf = design filter bed drain time (days) 1.67 Af = 981.9 sf required min. area of sand filter Est. Sand filter area 31.3 foot by 31.3 Filter Surface Area (Af=) 982 sf for calculations NOTE: top sand filter provided is 43' X 43' bottom of sand filter (41' X 41) is used to calculate outflow through the filter Actual Sand Surface Area Provided = 1600 sf Step 7 Verify the Volumes [At (St) + AS (Sf)] x hMa.Filter = 14909.25 cf >_ Filter area provided = 6100 sf Forebay area provided = 1625 sf hMa.Fiitar= 1.93 ft max head interpolated Step 8 Develop Water Quality Storage -Elevation Table Water Quality Stnra F=1evati- flat. /i-i... un- v.,..,ti_..� 9432 40 hrs cf minimum Elevation Area sf Area ac Ht ft Inc. Vol ac-ft Acc. Vol ac-ft Acc. Vol cf 684.5 1000.0 0.023 0.00 0.00 0.00 0.00 685 4450.0 0.102 0.50 0.03 0.03 1362.50 686 5500.0 0.126 1.50 0.11 0.15 6337.50 687 6700.00 0.154 2.50 0.14 0.29 12437.50 688 7950.00 1 0.183 3.50 0.17 0.45 19762.50 689 9050.00 0.208 4.50 0.20 0.65 28262.50 690 10150.00 0.233 1 5.50 0.22 0.87 37862.50 Top of Sand Filter Elevation 684.50 100 yr WSE 688.65 WQv Elevation = 686.43 WQv Required = 9431.61 cf 0.217 ac-ft per sand filter WQv treated = 9440.01 Jcf 0.217 ac-ft per sand filter Forebay Weir Elevation = 687 Top of Box Weir Elevation = 688.30 WQv release in (max 40 hrs) = IYES Step 9 Develop Stage -Discharge for Sand Filter Media Af = (WQv)(df)/[(k)(hf+df)(tf)] WQv/tf = Qo = Af (k)(hf+df)/(df)) where: Af = surface area of filter bed provided (ft2) df = filter bed depth (ft) k = coefficient of permeability of filter media (ft/day) hA = average height of water above filter bed (ft) At Elevation 687 2.5 feet above sand filter Qo = 9333 cf/da = 0.108 cfs At Elevation 686 1.5 feet above sand filter Qo = 7000 cf/da = 0.081 cfs At Elevation 685 0.5 feet above sand filter Qo = 4667 cf/da = 0.054 cfs At Elevation 684.5 sand filter surface Qo = 0 cf/da = 0.000 cfs Bottom of Sand Filter Elevation = Time to Drain WQV through sand filter = SHWT elevation = 1000.00 sf 1.50 ft 3.5 0.96 ft 682.00 40 hr NOT ENCOUNTERED AT ELEVATION 677.5 Step 10 Design Underdrain System The underdrain capacity must be greater than the filter media capacity. The capacity must drain the runoff volume from the system within design duration of 40 hours. The design must assume that 50 percent of the underdrain system (perforations and pipe system capacity) is lost due to clogging. Design specifications require the underdrain system to be a 8-inch perforated PVC pipe with 3/8-inch perforations spaced 3 inches on center, along 4 longitudinal rows spaced 90 apart. Minimum underdrain slope is 0.5 percent. Sand Filter Area = 981.92 sf The filter media is the controlling outflow condition. Compute minimum drawdown discharge Water Quality Volume = Drawdown = Compute Performation Capacity The maximum underdrain spacing is 10 feet on center. The dimension of the sand filter bottom is Actual length of pipe containing holes is 29 feet. Number of perforations = 50 percent of perforations = Capacity of one hole = CA(2gh)0.5 Total Capacity Filter Media Capacity = Total Capacity of Compute underdrain pipe capacity 9431.64 cf 9431.64 cf /(120 hrs)(3600 sec/hour) 0.022 cfs 33'x33' 1 i e 3 rows)((29) fUpipe)(4 holes/ft) 3481 holes 174 holes _(0.6)(3.1416)[(3/8in)(1/24)]2[(64.4)(5.0ft)]0.s 0.0083 cfs = 0.083 x 174 1.44 cfs 0.068 cfs at 1 foot of head 1.44 cfs is greater than Filter Media Capacity and Minimum Drawdown Discharge Underdrain Pipe Size = ©in = Area= For 6-inch PVC underdrain pipe at 0.005 fUft slope: Capacity of pipe = (1.49/n)(A)(A/P)o.67(S)o.5 _=(1.49/0.013)(0.196)(0.125)0 67(0.005)0.5 0.39 cfs Fifty percent assuming clogging = 0.20 cfs The underdrain pipe capacity (0.20 cfs) is greater than the filter media capacity of 0.068 cfs, and greater than the minimum drawdown capacity requirement (0.020 cfs computed in this step). Therefore the design is acceptable. Step 11 Design Overflow Weir A 16 foot emergency spillway overflow weir is designed with a weir elevation of 688.3 design elevation Step 12 Access Maintenance Access and Safety Features All areas of both chambers must be within 25 feet of an access location from the surface that is large enough for personnel to enter in order to remove trash, debris, sediment, etc. In addition, the sand filter media must be accessible in order to facilitate complete replacement when the sand filter ponds runoff without filtration. Check 50 year storm elevation - The 50 year storm events bypass the sand filters. The partial flow from these storms flowing to the sand filter stays within the sand filters with overflow over the outlet structure. 0.196 sf 0.125 Please complete the yellow shaded items. �� OF W A TF9 " Oa PG m- O Y NCDENR STORMWATER MANAGEMENT PERMIT APPLICATION FORM 401 CERTIFICATION APPLICATION FORM SAND FILTER SUPPLEMENT This form must be filled out on line, printed and submitted with all of the required information. Make sure to also fill out and submit the Required Items Checklist (Section Ill) and the 1&M Agreement (Section IV) !. PROJECT INFORMATION Project name AUTO FINANCE & CAR CARE CENTER Contact name Vincent G Keene, PE Phone number 704-556-1990 Date October 2, 2020 Drainage area number # 1 !l. DESIGN INFORMATION Site Characteristics Drainage area (AD) 211,701.60 ftZ OK Impervious area 113,994,00 ft' % Impervious (IA) 53.8% Design rainfall depth (RD) 1.00 in Peak Flow Calculations 1-yr, 24-hr runoff depth 1.38 in 1-yr, 24-hr intensity 0.11 in/hr Pre -development 1-yr, 24-hr runoff 3.22 ft3/sec Post -development 1-yr, 24-hr runoff 0.47 ft3/sec Storage Volume Design volume (WQV) 9,431.64 ft3 Adjusted water quality volume (WQVAdi) 9,431.64 ft3 Volume contained in the sedimentation basin and on top of the sand filter 9,440.00 ft3 Top of sand filter/grate elevation 684.50 ft amsl Weir elevation (between chambers) 687 ft amsl Maximum head on the sedimentation basin and sand filter (hMaxFilter) 1.93 ft Average head on the sedimentation basin and sand filter (hA) 0.96 ft Runoff Coefficient (Rv) 0.53 (unitless) Type of Sand Filter Open sand filter? Y Y or N NOT SHWT elevation ENCOUNTERED ft amsl AT ELEVATION 677.5 Bottom of the sand filter elevation 682.00 ft amsl Clearance (dsHwr) >2' Closed/pre-cast sand filter? N Y or N SHWT elevation ft amsl Bottom of the sand filter elevation ft amsl Clearance (dsHWT) If this is a closed, underground closed sand filter: The clearance between the surface of the sand filter and the bottom of the roof of the ft underground structure (dsp... Sedimentation Basin Surface area of sedimentation basin (As) 1,850.00 ft2 Sedimentation basin/chamber depth 2.00 ft Sand Filter Surface area of sand filter (AF) 10,150.00 ft2 Top of sand media filter bed elevation 684.50 It amsl Bottom of sand media filter bed/drain elevation 682.00 ft amsl Depth of the sand media filter bed (dF) 1.50 ft Coefficient of permeability for the sand filter (k) 3.50 (ft/day) Outlet diameter 6.00 in Outlet discharge/flowrate 0.20 ft3/sec Time to drain the sand filter (t) 40.08 hours Time to drain the sand filter (t) 1.67 days Additional Information Does volume in excess of the design volume bypass the sand filter? Y Y or N Is an off-line flow -splitting device used? N Y or N If draining to SA waters: Does volume in excess of the design volume flow evenly distributed throuqh a veqetated filter? N/A Y or N What is the length of the vegetated filter? ft Does the design use a level spreader to evenly distribute flow? Y or N Is the BMP located at least 30ft from surface waters (50ft if SA waters)? Y Y or N If not a closed bottom, is BMP located at least 100ft from water supply wells? Y Y or N Are the vegetated side slopes equal to or less than 3:1 Y Y or N Is the BMP located in a recorded drainage easement with a recorded access easement to a public Right of Way (ROW)? Y Y or N What is the width of the sedimentation chamber/forebay (Wsed)? 60.00 ft What is the depth of sand over the outlet pipe (dpipe)? 1.50 ft