HomeMy WebLinkAboutWQ0018489_Monitoring - 08-2020_20200918FORM : NDMR 10-13 NON -DISCHARGE MONITORING REPORT (NDMR)
Permit No.: W00018489 IFacility Name: South Cary Water Reclamation Facilit I I Month: August T Year: 2020
PPI: 001
Flow Measuring Point: [ ] Influent [x] Effluent [ ] No flow generated
Parameter Monitoring Point:[] Influent [x ] Effluent
Parameter Code
00310
31616
00610
00600
00665
00530
00076
1.00
O
C
O
o 2
m N
a
O
6
cn
r
O
O
p
O
m
E
o
o
U
LL
o
E
<
C
N
rn
o
Z
H
p
L
CL
In
o
a
o
t-
cn
F
r
o
n
T
L O
m
c
o s 3
g o
LL
o 0
~
24-hr
Y/N/B
m /L
#100 ml
m /L
m /L
m /L
m /L
m /L
MG
QQ,
1
Y
N
0.24
E
w
a
c
0
`
E
@73
W
_o
"
2
Y
N
0.20
3
Y
Y
<1
<0.05
1.44
0.18
0.22
4
Y
Y
<2.50
0.46
5
Y
Y
<2 0
<1
0.08
1.67
0.48
0.23
6
Y
Y
<2.50
0.26
7
Y
Y
<2.0
1.73
1.09
0.24
8
Y
N
0.23
9
Y
N
0.21
10
Y
B
<1
<0 05
1.51
0.23
0.20
11
Y
Y
<2.50
0.30
12
Y
Y
<2 0
<1
<0.05
1.74
1.36
0.24
13
Y
Y
<2.50
0.22
141
Y
I Y
<2 0
1.40
2.60
0.19
151
Y
I N
0.25
161
Y
I N
0.24to
<1
<0 05
1.77
0.70
0.21
18
Y
Y
<2.50
0.31
19
Y
Y
<2.0
<1
<0 05
2.04
1 1.27
0.20
20
Y
Y
<2.50
0.26
21
Y
Y
<2.0
1.88
1.82
0.24
22
Y
N
0.47
231
Y
I N
0.66
24
Y
B
<1
<0 05
1.50
0.35
0.66
25
Y
Y
1
<2.50
0.57
26
Y
B
<2 0
<1
<0.05
1.86
0.42
0.52
27
Y
B
<2.50
0.42
28
Y
Y
<2 0
1.43
0.93
0.36
291
Y
I N
0.30
30
Y
N
0.30
31
Y
Y
<1
<0.05
1.19
1 0.23
0.32
Average:
0.001
<1
0.01
1.63
0.90
<0.00
0.31
5.49
Daily Maximum:
0.00
<1
0.08
2.04
2.60
<2.50
0.66
Daily Minimum:
0.00
<1
<0.05
1.19
0.18
<2.50
0.19
Sampling Type:
Composite
Grab
Composite
Composite
Composite
Composite
Recorder
Estimate
Monthly Avg. Limit:
10
14 GeoM
4
10
2
5
Daily Limit:
15
25
6
10
10
Sample Frequency:
.%x Week
I 2x Week
2x Weekly
Weekly
Weekly
2 x Week
Cunt
Monthly
a vN��
*' NG
Permit Numbers Certified Laboratories
Name: South Cary WRF #W00018489 Name: South Cary WRF Certificate #278
Name: South Cary WRF NPDES #NC0065102 Name:
Does all monitoring data and sampling frequencies meet the requirements in Attachment A of your permit?
If the facility is non -compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the non-compliance
ana aescnoe the corrective action(s) taken. Attacn aaoltional sneets it necessarv.
Operator in Responsible Charge (ORC) Certification
Permittee Certification
ORC: Joseph C. Cummings
Permittee: Town of Cary
Certification No.: 999378
Signing Official: Jarrod Buchanan, PE
Grade: IV Phone Number: 919-779-0697
Signing Official's Title: South Cary WRF Manager
Has the ORC changed since the last NDMR? NO
Phone Number: 919-779-0697 Permit Expiration: 11/30/2025
D u>
Signature Date
signature D to
By this signature, I certify that this report is accurrate and complete to the best of my knowledge
I certify, under penalty of law, that this document and all attachments were prep red under
my direction or supervision in accordance with a system designed to assure that all qualified