HomeMy WebLinkAboutSW6200903_2020.10.21 - Winchester Subdivision CDs_20201022SEPTEMBER 14, 2020CONSTRUCTION PLANS FOR:File: C:\Users\DDS2\Desktop\Drafting and Design\2019\2019-23 Winchester Subdivsion\2020.04.22 - Winchester Subdivision CDs.dwg Print Date: 10/21/2020 SHEET INDEXC1 COVER SHEETC2EXISTING CONDITIONS PLANC3SUBDIVISION PLAN (PRELIMINARY PLAT)C4OVERALL CONSTRUCTION PLANC5PLAN/PROFILEGRAYSTONE LANESTA: 10+00 TO STA: 24+50C6PLAN/PROFILEHAYLOFT COURTSTA: 30+00 TO STA: 30+50PLAN/PROFILENEWCASTLE COURTSTA: 40+00 TO STA: 40+50PLAN/PROFILECRAFTSMAN COURTSTA: 50+00 TO STA: 50+50C7OVERALL GRADING AND DRAINAGE PLANC8EROSION CONTROL PLAN - INITIAL CONSTRUCTIONC9EROSION CONTROL PLAN - FINAL CONSTRUCTIONC10STORMWATER MANAGEMENT PLAN - CONVEYANCE SWALE DRAINAGE AREASC11-12 DETAILSC13-14DETAILS - NCDOTC15-20DETAILS - EROSION CONTROLLOCATION MAPSCALE: 1 INCH = 500 FTNORTHLOCATION MAPISSUEDFOR CONSTRUCTIONREINFORCED CONCRETE PIPETOP OF SIDEWALKTSBCBACK OF CURBR / WRCPC & GRIGHT OF WAYCURB & GUTTERPOLYVINYL CHLORIDE PIPETOP OF WALLTSPEDGE OF GRAVELEGLEGEND OF SYMBOLS AND LINESPVCDUCTILE IRON PIPEDIPCORRUGATED METAL PIPECMPCLEAN OUTCOTELEPHONE PEDESTALTPPOWER POLEPPLIGHT POLELPFIBER OPTIC BOXFOBFIBER OPTIC MARKERFOMWATER VALVEWVHIGH POINTHPWHEELCHAIR RAMPWCRGUY WIREGUYT.C.E.TEMPORARY CONSTRUCTION EASEMENTP.E.PERMANENT EASEMENTLEGEND OF ABBREVIATIONSINVERTINVFIRE HYDRANTFHFIBER OPTICFOCATCH BASINCBEXISTING IRON PINEIPEDGE OF PAVEMENTEPDROP INLETDIELECTRICAL BOXEBIRON PIN SETIPSJUNCTION BOX (STORM)JBNOW OR FORMERLYN/FEXISTING CONCRETE MONUMENTECMCORRUGATED PLASTIC PIPECPPELECTRICAL VAULTEVEXISTING PK NAILEPKSANITARY SEWER MANHOLESSMHYARD INLETYIWATER METERWMTRANSFORMERTFVALVE BOXVBSANITARY SEWERSS OR SANCALL BEFORE YOU DIGELEVATIONELUNDERGROUND COMMUNICATIONSUCSTAFFORD TURNER DEVELOPMENT PARTNERSHIP246 VALLEYFIELD LANESOUTHERN PINES, NC 28387CONTACT: BOB STAFFORDPHONE: (910) 692-9808DEVELOPER INFORMATIONTRAFFIC SIGNAL POLETWRAILROAD CROSSINGRRXTMHTELECOMMUNICATION MANHOLE143 Charlotte Avenue, Suite 104Sanford, North Carolina 27330(919) 777-6010 phonewww.jthomasengineering.comlicense no. C-3389J Thomas Engineering, Inc.civil engineering &planningTELEPHONE PEDESTALUTILITY POLEGATE VALVEFIRE HYDRANTSEWER MANHOLESEWER CLEANOUTCATCH BASINYARD INLET / DROP INLETSTORM JUNCTION BOX / MHPROPERTY CORNERWATER METERHANDICAPSPOT ELEVATIONSIGN100.00RIGHT OF WAYCURB AND GUTTEROVERHEAD ELECTRIC LINESANITARY SEWER (GRAVITY)STORM DRAIN PIPEWATER LINEGAS LINETREE LINEDRAINAGE FLOWCENTER LINEUNDERGROUND ELECTRIC LINECOMMUNICATIONS LINEFENCE LINEUEOHESANWGASTTWMCONCRETE PAVEMENTEXISTING FEATURES ARE SHOWN SHADED.SANITARY SEWER (FORCEMAIN)FMSIGNUTILITY EASEMENTLIMIT OF DISTURBANCEPROPERTY LINEASPHALT PAVEMENTCURB AND GUTTER (SPILL)LIGHT POLEFIBER OPTIC LINEFONOTE: ALIGNMENT CHANGEPVIDELTAGRAVEL SURFACEWINCHESTER SUBDIVISIONROCKFISH ROADHOKE COUNTY, NORTH CAROLINADDS Project No. 2019-23JTE Project No. 20-010TOP OF WALL TWBOTTOM OF WALL BWROCKFISH ROAD SR1406RAFTING AND DESIGNSERVICES, INC.6728 CARBONTON ROADSanford, North Carolina 27330(919) 499-8759 phonedraftinganddesign@ymail.comDDRAFTING BY:SITESWEET WILLIAM WAY SR 1774SITE DATADEVELOPERSTAFFORD TURNER DEVELOPMENT PARTNERSHIP246 VALLEYFIELD LANESOUTHERN PINES, NC 28387CONTACT: BOB STAFFORDPHONE:(910) 692-9808PROPERTY INFO:OWNER: STAFFORD-TURNER DEVELOPMENT PARTNERSHIPDB.1299 PG. 1034PIN #: 4948-40-30-1004AREA:30.71 AC +/-ZONING:RA-20LOT INFOPROPOSED LOTS= 33REQUIRED MIN LOT SIZE = 20,000 SFPROPOSED MIN LOT SIZE= 20,002 SFPROPOSED MAX LOT SIZE= 42,029 SFPROPOSED CHURCH PARCEL= 217,758 SFREQUIRED MIN LOT WIDTH = 80 FTPROPOSED MIN LOT WIDTH= 53FT @ SETBACK (CUL-DE-SAC)PROPOSED MAX LOT WIDTH=220 FTMIN LOT DEPTH= 98 FEETINFRASTRUCTUREROADWAY=2,398 FT5' SIDEWALK= 1,636 FT8" WATER LINE= 1,444 FT6" WATER LINE= 970 FTOPEN SPACEREQUIRED OPEN SPACE= NAPROPOSED OPEN SPACE =9.90 ACLOT SETBACKSFRONT = 30 FTREAR = 25 FTSIDE = 10 FTSIDE(CORNER) = 30 FTSANDSPUR COURT SR 1775SWIFT CREEK ROADPRIVATE ROADJODY LANEMYRA ROAD SR1466 SWIFT CREEK ROADRESUBMITTAL EC: SEPTEMBER 17, 2020RESUBMITTAL NCDOT DRIVEWAY PERMIT: OCTOBER 8, 2020RESUBMITTAL NCDOT, NCDEQ PWS, & NCDEQ STORMWATER, : OCTOBER 21, 2020 INV.=1 9 6. 3' INV.= 1 9 5 . 5 9' INV.= 1 9 8 . 6 5' INV.= 1 9 8. 4 6'727374757677787930' ACCESS EASEMENT (DB 226 PG 80)20' PERMANANT DRA INAGE EASEMENTPC3, SL IDE 3 -45 , MAP 008 RESE R V E D A D D I T I O N A L 1 0' R/ W PC 3 S L I D E 3 - 4 5, M A P 0 0 8 CTCT T96.66'S24° 23' 23"ENOFHARTLEY, DOROTHEA TPIN 494840301237ZONED: RA-20NOFFOWLER, KATHY MARIEPIN 494840301128ZONED: RA-20NOFPOPE, WAYNE MASTONPIN 494840301059ZONED: R-15NOFFOWLER, KATHY MARIEPIN 494840101106ZONED: RA-20W W W W W W W W W W501.92'S82° 22' 13"W143.98'N75° 38' 50"W1267.79'N03° 19' 42"E434.29'N86° 59' 47"E234.90'S11° 08' 26"W244.94'S83° 25' 53"E236.15'N05° 22' 12"E161.33'S77° 06' 39"E125.27'S21° 49' 45"E117.32'S68° 41' 28"E39.76'S25° 06' 12"E177.01'S24° 18' 21"E209.60'N65° 44' 15"E383.31'S24° 23' 51"E479.10'S62° 40' 48"W531.22'S59° 19' 53"WEX. 8" WATER LINEWEX. 8" WATER LINENOFHORNBECK, CAROLYN RPIN 494840101023ZONED: RA-20NOFGIBSON, DANIEL HPIN 494840101024ZONED: RA-20NOFMCCOLL, SUSAN DIANEPIN 494840101025ZONED: RA-20NOFHARTLEY, DOROTHEA TPIN 494840301237ZONED: RA-20NOFGIBSON, DANIEL HPIN 494840301003ZONED: R-15NOFFOWLER, KATHY MARIEPIN 494840101106ZONED: RA-20NOFHARDING, ANDREAPIN 494840301205ZONED: RA-20NOFSPENCE, PAUL E.PIN 494840101264ZONED: RA-202 0 0 200 205 19819819819 8 1 9 9 199 201 201 202 202 203 203 204 2 0 0 20520120 2 203204206197 19719819 8 199File: C:\Users\DDS2\Desktop\Drafting and Design\2019\2019-23 Winchester Subdivsion\2020.04.22 - Winchester Subdivision CDs.dwg Print Date: 10/21/2020 EXISTING CONDITIONS PLANC2Drawn by:Designed by:Reviewed by:Date:Scale:Sheet:Project Number:ofREVISIONS 80080160SCALE: 1" = 80'40NORTH1"=80'20PROFESSIONAL ENGINEER'S SEAL WINCHESTER SUBDIVISION MTBJRTJRTSEPTEMBER 14, 2020ROCKFISH ROAD HOKE COUNTY, NORTH CAROLINA 143 Charlotte Avenue, Suite 104Sanford, North Carolina 27330(919) 777-6010 phonewww.jthomasengineering.comlicense no. C-338918 SEPT 2020: REVISED PER EC COMMENTSISSUEDFOR CONSTRUCTIONJ Thomas Engineering, Inc.civil engineering &planningJTE #: 20-010DDS#: 2019-238 OCT 2020: REVISED PER DRIVEWAY PERMIT COMMENT MOVED CURB TIE TO 6' FROM TRAVEL LANE21 OCT 2020: REVISED PER NCDOT COMMENTS, NCDEQPWS & NCDEQ STORMWATER PERMIT COMMENTSTREE LINE (TYP) ROCKFISH ROAD - SR#1406VARIABLE R/WEX. 18" RCP CULVERTEX. 24" RCP CULVERTSWEET WILLIAM WAYSR 177450' R/WEX. 15" RCP CULVERTEX. 15" RCP CULVERTEX. POWER POLETO BE RELOCATEDEX. DRAINAGE SWALEEX. FENCEPROPERTY LINE OVERLAPEX. DIRT ROAD (TYP)EX. 30' ACCESSEASEMENT (TYP)TREE LINE (TYP)UNSUITABLE SOILS (TYP)NOTES:1.BOUNDARY SURVEY INFORMATION PER AVERETTE ENGINEERING CO., PA PLAT DATEDJANUARY, 15, 2020. PROVIDED BY OWNER.2.DESIGN SURVEY INFORMATION PER AVERETTE ENGINEERING CO., P.A. DATED JAN 132020.PROVIDED BY OWNER.3.TOPOGRAPHIC FEATURES SHOWN ON THESE PLANS ARE FROM THE STATE'S LIDARDATA. THE OWNER'S SURVEYOR SUPPLIED FIELD LOCATIONS AND ELEVATIONS INCERTAIN AREAS WHERE MORE DETAIL WAS NEEDED FOR DESIGN.4.SUITABLE SOIL SURVEY PER HAL OWEN & ASSOCIATES, INC. SOILS LOCATIONS SHOWNPER REPORT AND MAP DATED JUNE 1, 1994. PROVIDED BY OWNER.5.NO JURISDICTIONAL STREAMS AND WETLANDS DELINEATION HAS BEEN VERIFIED BYTHE OWNER.6.THERE ARE NO FEMA FLOODPLAINS CONTAINED ON THIS SITE PER FIRM PANEL 3710948400K, PANELS 9484, EFFECTIVE DATE JAN 5, 2007.8.ALL SUB-SURFACE UTILITIES IDENTIFIED ON THE EXISTING CONDITION PLAN ARESHOWN IN THEIR APPROXIMATE LOCATION BASED ON SURVEY INFORMATIONGATHERED FROM FIELD INSPECTION AND/OR ANY OTHER APPLICABLE RECORDDRAWINGS WHICH MAY BE AVAILABLE.9.REVIEW AND APPROVAL OF THE PLANS DOES NOT RELIEVE THE OWNER,CONTRACTOR, OR DEVELOPER FROM MEETING ALL THE REQUIREMENTS OF HOKECOUNTY DEVELOPMENT ORDINANCE, AND ANY OF THE STATE, AND FEDERALREGULATIONS AND APPROVALS.10.ALL IMPROVEMENTS OR EXTENSIONS OF PUBLIC INFRASTRUCTURE UNDER THECOUNTY'S JURISDICTION SHALL BE IN STRICT ACCORDANCE WITH THE HOKE COUNTYORDINANCES, REGULATIONS, POLICIES, REQUIREMENTS, AND SPECIFICATIONS.11.PLANS BASED ON APPROVED PRELIMINARY SUBDIVISION PLAT PREPARED BYDRAFTING AND DESIGN SERVICES, INC, DATED JANUARY AND APPROVED BY COUNTYCOUNCIL ON JULY 6, 2020. MINOR CHANGES MAY HAVE TO BE MADE TO THE ROADCENTERLINE AND LOT LINES BASED ON ACTUAL FIELD CONDITIONS. THOSE CHANGESWILL BE REFLECTED ON THE FINAL PLAT.12.THE PROPERTY BOUNDARY SHOWN ON THESE PLANS WAS PROVIDED BY THEOWNER'S SURVEY.13.OWNER TO OBTAIN CONSTRUCTION EASEMENTS/AGREEMENTS PRIOR TO ANYOFF-SITE WORK (IF NECESSARY).14.FINAL LOCATION OF WATER METERS, FIRE HYDRANTS, AND WATER VALVES ARE TO BEDETERMINED BY THE PROJECT DEVELOPER / CONTRACTOR WITH APPROVAL FROMCOUNTY. APPROPRIATE BACKFLOW PREVENTION IS REQUIRED FOR ANY IRRIGATIONMETERS INSTALLED.15.SEE PLAN / PROFILE SHEETS FOR ADDITIONAL DESIGN AND LAYOUT INFORMATION.16.CONTRACTOR TO VERIFY QUANTITIES SHOWN ON PLANS BASED ON ACTUAL FIELDCONDITIONS.17.WATER SYSTEM CONSTRUCTION SHALL BE INSTALLED IN ACCORDANCE WITH HOKECOUNTY PUBLIC UTILITIES REQUIREMENTS AND SPECIFICATIONS.18.PLACE TRACING WIRE (OR TAPE) ON ALL NON-METALLIC UTILITY PIPES, FOR THEENTIRE LENGTH OF THE PIPE.19.ELECTRICAL POWER AND COMMUNICATION FACILITIES SHOULD CONFORM TO THECURRENTLY APPLICABLE NATIONAL ELECTRIC SAFETY CODE EXCEPT VERTICAL&/($5$1&(66+$//%(/(667+$1´,1$1<&$6(20.ALL UTILITY STRUCTURES SHALL BE LOAD RATED FOR THE APPROPRIATE DEAD LOADPLUS HL-93 LIVE LOAD. SUCH STRUCTURES SHALL BE DESIGNATED AND CERTIFIED BYA LICENSED PE OR DESIGNATED AS MEETING NCDOT STANDARD DRAWINGS ANDSPECIFICATIONS.21.ALL ASHPALT WORK TO BE ACCEPTED BY THE NCDOT AND MUST BE IN ACCORDANCEWITH NCDOT STANDARD SPECIFICATIONS FOR ROADS AND STRUCTURES (JANUARY2018), AND NCDOT PAVEMENT SECTIONS.22.NCDOT MUST REVIEW AND APPROVE ANY SUBDIVISION NAME SIGNS OR MARKERS. IFA SUBDIVSION MARKER IS USED FOR ENTRANCE IT MUST BE LOCATED OUTSIDE THER/W.23.ALL PERMANENT DRAINAGE EASEMENTS (P.D.E.) SHALL NOT BE MAINTAINED BY THENCDOT. P.D.E.'S SHALL BE MAINTAINED BY THE HOMEOWNER'S ASSOCIATION SET UPFOR THIS SUBDIVISION. IF NO HOMEOWNER'S ASSOCIATION IS FORMED, THEINDIVIDUAL PROPERTY OWNER SHALL BE RESPONSIBLE FOR MAINTENANCE.STAFFORD-TURNER DEVELOPMENT PARTNERSHIP4948-40-30-100430.71 AC +/-ZONED: RA-20UNSUITABLE SOILS (TYP) GRAYSTONE LANEHAYL O F T C O U R T CRAFTSMAN COURT NEWCASTLE COURT22,159 SF0.51 AC234567158169171011121314181920212223242526272820,714 SF0.48 AC21,296 SF0.49 AC24,224 SF0.56 AC20,033 SF0.46 AC22,358 SF0.51 AC22,362 SF0.51 AC21,226 SF0.49 AC27,734 SF0.64 AC20,018 SF0.46 AC20,340 SF0.47 AC20,052 SF0.46 AC20,025 SF0.46 AC20,004 SF0.46 AC20,002 SF0.46 AC20,049 SF0.46 AC20,034 SF0.46 AC20,600 SF0.47 AC20,025 SF0.46 AC20,025 SF0.46 AC27,863 SF0.64 AC22,325 SF0.51 AC23,049 SF0.53 AC20,127 SF0.46 AC25,712 SF0.59 AC41,913 SF0.96 AC23,134 SF0.53 AC24,981 SF0.57 AC25,122 SF0.58 ACOPENSPACE431,476 SF9.90 AC121,368 SF0.49 AC29NOFHARTLEY, DOROTHEA TPIN 494840301237ZONED: RA-20NOFFOWLER, KATHY MARIEPIN 494840301128ZONED: RA-20NOFPOPE, WAYNE MASTONPIN 494840301059ZONED: R-15NOFFOWLER, KATHY MARIEPIN 494840101106ZONED: RA-20306ƒ (120.006ƒ       : 133.4 96  ƒ       : 186 .5 01ƒ (70.631ƒ       ( 209.6 8 6ƒ (110.001ƒ :110.586ƒ :96.681ƒ :197.1069.84' 6ƒ : 141.51 1ƒ (216.1765.00 ' 6   ƒ       : 2 3 1 . 2 2 6ƒ (224.8772.89'6ƒ :114.571ƒ :70.006ƒ : 206.98 66.04' 6ƒ ( 98.68 39.35'1ƒ :93.721ƒ ( 100.76 1ƒ ( 45.62 1ƒ (99.416ƒ (77.576ƒ ( 98.68163.67'26.49'39.27'1ƒ (75.006ƒ (175.621ƒ :200.001ƒ       ( 100.0 0 1ƒ :96.661ƒ :39.761ƒ :56.7829.91'6ƒ :50.001 ƒ   (117.351ƒ :60.541ƒ :125.271ƒ :87.956ƒ ( 176.63 85.83'1ƒ :68.091ƒ ( 236.15 6ƒ (73.3875.85'6ƒ (75.0039.27'34.33'72.95'1ƒ :34.116ƒ       : 235.0 8 6ƒ       : 235.0 81ƒ :77.2322.80'1ƒ        ( 219.1 6 6ƒ (55.996ƒ (33.9842.46'1ƒ :57.551ƒ (218.026ƒ (159.076ƒ (191.256ƒ : 106.531ƒ :162.3439.27'1ƒ ( 81.46 1ƒ ( 111.49 1ƒ :29.886ƒ :10.111ƒ :163.881ƒ     ( 189.51 6ƒ   :193.1973.94'21.45'58.54'1ƒ     ( 104.80 1ƒ (193.936ƒ     : 55.506ƒ   :193.1985.07'6ƒ :240.366ƒ :25.056ƒ (177.071ƒ :183.611ƒ (174.24 74.91'16.95'6ƒ (186.871ƒ ( 108.00 6ƒ :107.73 39.27'1ƒ ( 82.00 6ƒ :107.33 1ƒ ( 222.50 6ƒ (105.0039.27'6ƒ : 161.4323.22'1ƒ ( 222.50 6ƒ (90.001ƒ :90.006ƒ (90.001ƒ :90.006ƒ (90.026ƒ : 222.501ƒ :95.151ƒ (222.56 147.72'1ƒ       ( 209.8 3 1ƒ :134.5557.58'1ƒ :7.8039.27'6ƒ : 161.43 23.22'10.86'EXISTINGROCKFISH ROAD R/W (TYP)29.0' B-B24" ASPHALTNCDOT ROLL CURB (TYP)R35.0'R35.0 'R35.0'10.5'29.0' B-B10.5'29.0' B-B10.5'29.0' B-B10.5'20' PERMANENTDRAINAGE EASEMENT (TYP)20' PERMANENTDRAINAGE EASEMENT (TYP)20' PERMANENTDRAINAGE EASEMENT (TYP)BUILDING SETBACK (TYP)BUILDING SETBACK (TYP) EX. 30' ACCESS EASEMENTDB 226, PG 80FENCE ENCROACHMENTR35.0'R 3 5 . 0 'R35.0 ' TYPR58.5' R/WR48.5 C-BR58.5' R/WR3 5 .0 ' TY PR35.0'R 3 5 . 0 'R35.0' TYPR48.5' C-BR58.5' R/W5' CONCRETESIDEWALK (TYP)PUBLIC5' SIDEWALKEASEMENT (TYP)PROPOSED NCDOT50' PUBLIC R/W (TYP)WCRWCRWCRWCRWCRS87° 59' 34"E214.92'S87° 59' 34"E267.32'C1S73° 19' 45"E199.66'S73° 19' 45"E215.84'C2N65° 54 ' 53 "E119.43 ' N02° 00' 26"E 328.31' S02° 00' 26"W 350.67' N16° 3 5 ' 5 6 " E 326.6 8 'WCRWCRFIRE HYDRANT500FT SPACING (TYP)TREE LINE (TYP)WOODSWOODSEXISTING DRAINAGE SWALE (TYP)PROPOSEDMAIL KIOSK PARKINGPER NCBC 1106.12 SPACES (INCLD HC)PROPOSEDMAIL KIOSKWCREX. EOP (TYP)WCREX. DIRT DRIVE (TYP)1ƒ (31.381ƒ :165.846ƒ (164.3525,119 SF0.58 AC3124,947 SF0.57 AC3233,472 SF0.77 AC336ƒ : 230.081ƒ :129.921ƒ     ( 230.00 6ƒ ( 230.086ƒ :129.916ƒ     ( 227.356ƒ :129.7090.43'1ƒ   (31.7139.19'6ƒ (191.406ƒ   :131.3351.56'90.45'90.44'1ƒ :143.986ƒ :501.926ƒ   :531.226ƒ   :313.811ƒ (129.706ƒ (54.956ƒ (24.52R35. 0 '10A6ƒ : 83.23 6ƒ  :54.441ƒ :99.446ƒ :128.8511A6ƒ :74.75 1ƒ :175.151ƒ ( 74.736ƒ (178.181ƒ (25.871ƒ (580.87 FUTUREROCKFISH ROAD R/W (TYP)UNSUITABLE SOILS (TYP)UNSUITABLE SOILS (TYP)RESERVED FORFUTURE R/WRESERVED FORFUTURE R/WFUTUREROCKFISH ROAD WIDENINGCURB RADIUS TIE (TYP)R48.5 ' C -B20' PRIVATEUTILITY/ACCESSEASEMENT (TYP10' PRIVATEUTILITYEASEMENT (TYP20' PRIVATEUTILITY/ACCESSEASEMENT (TYP10' PRIVATEUTILITYEASEMENT (TYP)PERMANENTDRAINAGEEASEMENT (TYP) 20' PERMANENTDRAINAGE EASEMENT (TYP)20' PERMANENTDRAINAGE EASEMENT (TYP)ROCKFISH ROAD - SR 1403NOFHORNBECK, CAROLYN RPIN 494840101023ZONED: RA-20NOFGIBSON, DANIEL HPIN 494840101024ZONED: RA-20NOFMCCOLL, SUSAN DIANEPIN 494840101025ZONED: RA-20NOFHARTLEY, DOROTHEA TPIN 494840301237ZONED: RA-20NOFGIBSON, DANIEL HPIN 494840301003ZONED: R-15NOFFOWLER, KATHY MARIEPIN 494840101106ZONED: RA-20NOFHARDING, ANDREAPIN 494840301205ZONED: RA-20NOFSPENCE, PAUL E.PIN 494840101264ZONED: RA-2042.46'1ƒ :90.001ƒ       ( 143.0 87.81'SWEET WILLIAM WAY - SR 177420' PERMANENTDRAINAGEEASEMENT (TYP)PERMANENTDRAINAGE EASEMENT (TYP)ROCKFISH ROADCURB RADIUS 6' SETBACKTAPER PAVEMENT (TYP)50.0'PUBLIC R/W50.0'PUBLIC R/W50.0'PUBLIC R/W50.0'PUBLIC R/WCENTER LINE CURVE TABLECURVE #C2C1LENGTH355.66'63.98'RADIUS500.00'250.00'DELTAƒ ƒ CHORD BEARING1ƒ (6ƒ (CHORD LENGTH348.21'63.81'R35.0'R3 5 . 0 'DEVELOPMENT SIGNEASEMENT (TYP)20'X25'DEVELOPMENT SIGNEASEMENT (TYP)20'X25'File: C:\Users\DDS2\Desktop\Drafting and Design\2019\2019-23 Winchester Subdivsion\2020.04.22 - Winchester Subdivision CDs.dwg Print Date: 10/21/2020 SUBDIVISION PLAN (PRELIMINARY PLAT)C3Drawn by:Designed by:Reviewed by:Date:Scale:Sheet:Project Number:ofREVISIONS 80080160SCALE: 1" = 80'40NORTH1"=80'20PROFESSIONAL ENGINEER'S SEAL WINCHESTER SUBDIVISION MTBJRTJRTSEPTEMBER 14, 2020ROCKFISH ROAD HOKE COUNTY, NORTH CAROLINA 143 Charlotte Avenue, Suite 104Sanford, North Carolina 27330(919) 777-6010 phonewww.jthomasengineering.comlicense no. C-338918 SEPT 2020: REVISED PER EC COMMENTSISSUEDFOR CONSTRUCTIONJ Thomas Engineering, Inc.civil engineering &planningJTE #: 20-010DDS#: 2019-238 OCT 2020: REVISED PER DRIVEWAY PERMIT COMMENT MOVED CURB TIE TO 6' FROM TRAVEL LANE21 OCT 2020: REVISED PER NCDOT COMMENTS, NCDEQPWS & NCDEQ STORMWATER PERMIT COMMENTSNOTES:1.NO ON-SITE STREAMS OR WETLAND DELINEATION HAS BEEN PROVIDED BY OWNER.2.SETBACKS ARE SHOWN IN ACCORDANCE WITH THE APPROVED HOKE COUNTY ZONINGSTANDARDS.3.UTILITY AND PIPELINE EASEMENTS SHALL BE RECORDED AS PART OF THE SUBDIVISIONPLAT AFTER CONSTRUCTION IS COMPLETED.4.COMMON OPEN SPACE SHALL BE MAINTAINED BY THE NEIGHBORHOOD HOMEOWNERSASSOCIATION. OPEN SPACE INCLUDES A BLANKET DRAINAGE AND ACCESS EASEMENT FORTHE STORMWATER DRAINAGE SWALES.5.ADJACENT OPEN SPACE WILL BE RECORDED AS LOTS ARE RECORDED.6.TREES SHALL NOT BE PLANTED IN ANY STORM DRAINAGE OR UTILITY EASEMENTS.7.ALL PROPOSED PAVEMENT SECTIONS ARE MINIMUM STANDARDS. FINAL PROPOSEDPAVEMENT SECTION DESIGNS WILL NEED TO BE PROVIDED TO HOKE COUNTY/NCDOT FORREVIEW AND APPROVAL PRIOR TO PLACEMENT OF ANY BASE MATERIAL.8.REFER TO DETAIL ON SHEET C11 FOR TYPICAL ROAD CROSS SECTIONS.9.ADA RAMPS SHALL BE CONSTRUCTED TO NCDOT SPECIFICATIONS WITH A 4'x4' LANDINGAREA AND 48" PASSING DISTANCE BEHIND RAMP.10.MAIL SERVICE TO BE PROVIDED AS CLUSTER BOX UNIT (CBU)PER USPS REQUIREMENTS.PER DOI NCDOT DOCUMENTATION ONE 25 FT LONG SPACE HAS BEEN PROVIDED PER 20UNITS WITH MIN ONE ADA ACCESSIBLE SPACE WITH MIN SLOPE AND LAYOUTREQUIREMENTS PER DETAIL ON SHEET C11.11.ALL MATERIALS AND METHODS OF CONSTRUCTION SHALL BE IN ACCORDANCE WITH HOKECOUNTY STANDARDS, SPECIFICATIONS AND DETAILS.12.ALL DIMENSIONS ARE TO BACK OF CURB UNLESS OTHERWISE NOTED.13.DEVELOPER/HOME BUILDER IS RESPONSIBLE FOR INSTALLATION OF PROPOSEDSIDEWALKS. THE SIDEWALKS ARE TO BE OUTSIDE OF THE RIGHT-OF-WAY IN A 5 FT WIDEEASEMENT.14.HOKE COUNTY PUBLIC WORKS IS RESPONSIBLE FOR SIDEWALK AND ADA RAMPMAINTENANCE.15.NO TREES SHALL BE PLANTED IN THE PROPOSED NCDOT R/W.16.ALL STREETS ARE TO BE DEDICATED TO NCDOT UPON COMPLETION.17.MAIL KIOSK (CBU) SHALL BE ADA COMPLIANT/SHALL BE CONSTRUCTED & MAINTAINED BYHOA.18. DRIVEWAYS FOR ALL LOTS CREATED WITHIN THIS SUBDIVISION SHALL ACCESS INTERNALSUBDIVISION ROADS AND NOT HAVE ACCESS TO SR 1403 (ROCKFISH ROAD).19.DRAINAGE STRUCTURES WITHIN R/W MUST BE CONSTRUCTED PER NCDOT STANDARDDRAWINGS/STATE NOT RESPONSIBLE FOR MAINTAINING DRAINAGE STRUCTURES OUTSIDEOF R/W.20. STOP SIGN SHALL BE INSTALLED AT SR 1403 (ROCKFISH ROAD) AND AT ALL INTERIORINTERSECTIONS, PER NCDOT STANDARDS.21.NCDOT DISTRICT OFFICE CERTIFICATION BLOCK IS REQUIRED ON FINAL PLAT.22. ALL DRAINAGE SYSTEMS/EASEMENTS OUTSIDE OF THE NCDOT RIGHT OF WAY SHALL BEMAINTAINED BY THE HOA.23.DEVELOPER/RESIDENT OF SUBDIVISION TO REQUEST SPEED STUDY FROM TRAFFICSERVICES ONCE INTERNAL STREETS ARE DEDICATED FOR THE APPROPRIATE STREETSPEED AND THE LOCATION OF THE POSTED SPEED LIMIT AT THE SUBDIVISION ENTRANCE.24. ALL PUBLIC UTILITIES SHALL BE INCLUDED IN ENCROACHMENT AGREEMENTS AT TIME OFRIGHT OF WAY DEDICATION.MAIL KIOSK (SITE PLAN)SCALE: 1"=30'USPS APPROVEDKIOSK UNITS (TYP)6" CONCRETEPAD (TYP)30" ROLLED CURB (TYP)2 SPACESSIDEWALK FLUSHTO PAVEMENT8.0'25.0'25.0'25.0'25.0'6.0'4.0'8.0'CONCRETESIDEWALK (TYP)NCDOT R/W (TYP) GRAYSTONE LANEHAYL O F T C O U R T CRAFTSMAN COURT NEWCASTLE COURT33+18 30+0 0 31+00 32+00 33+0 0 50+00 51+00 52+00 53+00 53+51 PC: 11+19.4PT: 1 4 + 7 5 . 1 PC: 1 8 + 9 0 . 6 PT: 19+54.6 W W W W W WWWWWWWWWWWWWWWWWWWWWWWWW23456715816917101112131418W W W W W WWWWWWW19202122232425262728OPENSPACE129W W W W W W W W W W30 W31323310A11A24+3710+0011+0012+0013+0014+0015+0016+0017+0018+0019+0020+0021+0022+0023+0024+00ROCKFISH ROAD - SR 140343+28 40+0041+0042+0043+00 SWEET WILLIAM WAY - SR 1774File: C:\Users\DDS2\Desktop\Drafting and Design\2019\2019-23 Winchester Subdivsion\2020.04.22 - Winchester Subdivision CDs.dwg Print Date: 10/21/2020 OVERALL CONSTRUCTION PLANC41"=80'Drawn by:Designed by:Reviewed by:Date:Scale:Sheet:Project Number:ofREVISIONS 80080160SCALE: 1" = 80'40NORTH20PROFESSIONAL ENGINEER'S SEAL WINCHESTER SUBDIVISION MTBJRTJRTSEPTEMBER 14, 2020ROCKFISH ROAD HOKE COUNTY, NORTH CAROLINA 143 Charlotte Avenue, Suite 104Sanford, North Carolina 27330(919) 777-6010 phonewww.jthomasengineering.comlicense no. C-338918 SEPT 2020: REVISED PER EC COMMENTSISSUEDFOR CONSTRUCTIONJ Thomas Engineering, Inc.civil engineering &planningJTE #: 20-010DDS#: 2019-238 OCT 2020: REVISED PER DRIVEWAY PERMIT COMMENT MOVED CURB TIE TO 6' FROM TRAVEL LANE21 OCT 2020: REVISED PER NCDOT COMMENTS, NCDEQPWS & NCDEQ STORMWATER PERMIT COMMENTSPROPOSED DEAD-END ROADFOR FUTURE CONNECTIONPROPOSED 5' SIDEWALKEASEMENT (TYP)PROPOSED NEW ROADWAY (TYP)NCDOT MAINTAINEDSEE DETAIL SHEET C11PROPOSED 8" WATER LINETO CONNECT TO EX. 8" WATER LINEMAIL KIOSKSEE SHEETS C3,C7,C11PROPOSED VEGETATIVECONVEYANCE SWALE (TYP)PROPOSED VEGETATIVECONVEYANCE SWALE (TYP)PROPOSED PERMANENTSTORM EASEMENT (TYP)PROPOSED PERMANENTSTORM EASEMENT (TYP)PROPOSEDSTORM DRAINAGE (TYP)PROPOSEDSTORM DRAINAGE (TYP)PROPOSED PERMANENTSTORM EASEMENT (TYP)PROPOSED5' SIDEWALK (TYP)PROPOSEDGRAYSTONE LANECONNECTION TO ROCKFISH ROADPROPOSEDLOT DRAINAGESWALE (TYP)10x70 NCDOTSITE TRIANGLE (TYP)FUTURE ROCKFISHROAD R/W10x70 NCDOTSITE TRIANGLE (TYP)10x70 NCDOTSITE TRIANGLE (TYP)10x70 NCDOTSITE TRIANGLE (TYP)PROPOSED WATER LINE3.0' OFF BACK OF CURB (TYP)NOTES:1.STOP SIGNS SHALL BE INSTALLED AT ALL STOP INTERSECTIONS PER NCDOT STANDARDS.REFER TO DETAIL ON SHEET C11.2.ENCROACHMENT IS REQUIRED FOR ADA RAMPS (WCR) AT THE TIME OF INTERNAL STREETDEDICATION TO NCDOT.3.ENCROACHMENTS ARE REQUIRED FOR PROPOSED ENCASEMENTS FOR FUTURE SEWERFORCE MAIN WITH IN THE DEDICATED NCDOT RIGHT OF WAY.4.ENCROACHMENTS ARE REQUIRED FORSTOP SIGNR1-1 (TYP)STOP SIGNR1-1 (TYP)STOP SIGNR1-1 (TYP)STOP SIGNR1-1 (TYP)PROPOSEDFIRE HYDRANT (TYP)PROPOSED NCDOT50' PUBLIC R/W (TYP)EXISTINGACCESS EASEMENT (TYP) PC: 11+19.4PT: 14+75.1 PC: 18 + 9 0 . 6 PT: 19+54.6 WWWWW WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW23489101118WWWWW W W W W W W W W W 1920212223262728129NOFHARTLEY, DOROTHEA TWWW30C1C2W31323310A11AX 199.7X 199.7X 201.0X 199.4X 199.6X 201.0X 200.10EPX 199.85EPX 200.28EPX 199.66EP199.0 0 X EP199.52 XEPX 199.52EP202.00 XEPX 202.0 EP 199.27 XEPX 199.59EPX 201.43EPX 201.51EPX 200.45EPX 200.45EPX 200.30EPX 200.30EPX 198.5FES 101FES 100FES 200CB 201CB 202CB 203ADI 204CB 206FES 207CB 301CB 401FES 400CB 403CB 404CB 208X 199.5X 199.5X 199.5X 199.5X 199.5X 201.0X 201.0FLUME 2FLUME 1FPE=200.5200FPE=200.5FPE=201.5FPE=201.5FPE=201.5FPE=201.5FPE=202.5FPE=202.5FPE=202.0FPE=201.5FPE=201.0FPE=201.5FPE=201.5FPE=201.5FPE=201.5FPE=200.5FPE=200.5FPE=201.5FPE=201.5FPE=201.5FPE=201.5FPE=201.5X 201.0CB 402FES 405X 200.26TOS 200.01 XTOS X 200.0X 201.0H.P.X 199.0WMWM WMW M WMWMWMWMWMWMWMWMWM WMWMWMWMWM24+3710+0011+0012+0013+0014+0015+0016+0017+0018+0019+0020+0021+0022+0023+0024+00NOFHARTLEY, DOROTHEA TX 201.00 EP201.1 XEPDI 406DI 407X 201.0CB 203CB 205X 201.0X 201.0200200200200200200X 201.0X 199.5X 199.5200 200200200200X 201.0JB 401AJB 201AJB 301A18018519019520020521021518018519019520020521021510+00199.4200.111+00200.0200.012+00199.9199.913+00200.0200.014+00200.0200.015+00200.0 200.0 16+00200.0 200.0 17+00200.0 200.0 18+00200.0 200.0 19+00200.0 200.0 20+00200.0 200.0 21+00200.0 200.0 22+00200.0 200.2 23+00200.6 201.0 24+00201.5 24+50200.88201.68202.14201.93201.62201.31201.01200.70200.40 200.09 199.78 199.49 199.44 199.70 199.98 200.27 200.55 200.84 201.13 201.41 201.70 201.99 202.27 202.56 202.85 203.13 203.42 203.71 -1.60%1.82%-0.61%0.57%-2.00%HIGH POINT STA: 11+54.83HIGH POINT EL= 202.14'PVI STA: 11+35.00PVI EL= 202.32'K= 32.9480.00' VCLOW POINT STA: 16+31.32LOW POINT EL= 199.41'PVI STA: 16+30.00PVI EL= 199.29'K= 67.5080.00' VC72 LF - 24" RCP @ 0.69% (100-101)CLASS IVSD FLARED END SECTION 101STA:10+78.5 (37.9R)INV IN: 197.50SD FLARED END SECTION 100STA:10+80.5 (33.5R)INV IN: 197.00SD CATCH BASIN 203ASTA: 16+31.3 (12.0R)GRATE EL: 198.90INV IN: 195.07 (204)INV OUT: 195.07SD CATCH BASIN 203STA: 16+46.4 (12.0R)GRATE EL: 198.90INV IN: 194.97 (208)INV OUT: 194.97SD CATCH BASIN 202STA: 16+31.3 (12.0L)GRATE EL: 198.90INV OUT: 194.89SD CATCH BASIN 201STA: 16+46.0 (12.0L)GRATE EL: 199.00INV IN: 194.77 (203)INV IN: 194.77 (202)INV OUT: 194.77SD CATCH BASIN 208STA:17+41.9 (12.0R)GRATE EL: 199.67INV OUT: 195.87SD CATCH BASIN 401STA: 22+57.4 (12.0L)GRATE EL: 202.63INV IN: 196.60 (402,403)INV OUT: 196.60SD FLARED END SECTION 400STA:22+56.8 (329.0L)INV OUT: 194.3990.9 LF - 18" RCP @ 0.9% (401-403)CLASS IIISD FLARED END SECTION 200STA: 16+45.5 (234.7L)INV OUT: 193.6718 LF - 15" RCP @ 0.5% (201-202)CLASS IV96 LF - 24" RCP @ 0.8% (203-208)CLASS IV15 LF - 15" RCP @ 0.67% (203A-203)CLASS IVSD CATCH BASIN 402STA: 24+25.3 (12.0L)GRATE EL: 203.59INV IN: 198.20 (405)INV OUT: 198.20SD FLARED END SECTION 405STA:24+25.3 (46.1L)INV IN: 198.8460 LF - 30" RCP @ 1.0% (402-405)CLASS III162 LF - 30" RCP @ 1.0% (401-402)CLASS IIIC/L INTERSECTIONSTA: 10+00.00EL: 201.68 C/L INTERSECTION STA: 16+90.93 = 30+00.00 EL: 199.64 C/L INTERSECTION STA: 20+12.38 = 40+00.00 EL: 201.482 C/L INTERSECTION STA: 22+21.90 = 50+00.00 EL: 202.686 C/L END PAVEMENT STA: 24+26.82 EL: 203.8618" MIN VERTICAL CLEARANCEBETWEEN STORM AND WATER18" MIN VERTICAL CLEARANCEBETWEEN STORM AND WATER18" MIN VERTICAL CLEARANCEBETWEEN STORM AND WATER18" MIN VERTICAL CLEARANCEBETWEEN STORM AND WATER8" PVC - WATER LINE (SDR-21)8" PVC - WATER LINE (SDR-21)3.0' MIN COVERF.H.F.H.F.H.EXISTING GROUND @ CLPROPOSED FINISHGRADE @ CLPRO. GRADEEX. GROUND3:1 SLOPE (MAX)18" MIN VERTICAL CLEARANCEBETWEEN CONDUIT AND WATERF.H.START STEEL CASINGSTA: 9+80.47BORE & JACKSTA: 10+21.4716" STEEL CASING90° BENDS (2)EX. 8" PVC6" PVC6" PVC6" PVCSD DROP INLET 204(DOUBLE INLET)STA: 16+31.3 (34.8R)GRATE EL: 199.00INV IN: 196.07 (205)INV OUT: 196.0720 LF - 15" RCP @ 0.50% (203A-204)CLASS IIISD FLARED END SECTION 207STA: 17+35.11 (51.4R)GRATE EL: 199.00INV OUT: 197.00122 LF - 24" RCP @ 0.5% (207-208)CLASS IIISD JUNCTION BOX 401ASTA: 22+57.4 (27.0L)RIM EL: 203.25INV IN: 196.51 (401)INV OUT: 196.5128 LF - 24" RCP@ 0.71% (201-203)CLASS III4.0' MIN COVEREND STEEL CASINGSTA: 10+62.88SD JUNCTION BOX 201ASTA: 16+46.0 (27.0L)GRATE EL: 199.62INV IN: 194.71 (201)INV OUT: 194.71File: C:\Users\DDS2\Desktop\Drafting and Design\2019\2019-23 Winchester Subdivsion\2020.04.22 - Winchester Subdivision CDs.dwg Print Date: 10/21/2020 PLAN/PROFILE GRAYSTONE LANE STA: 10+00 TO STA: 24+50C5Drawn by:Designed by:Reviewed by:Date:Scale:Sheet:Project Number:ofREVISIONS NORTH 1"=50'20PROFESSIONAL ENGINEER'S SEAL WINCHESTER SUBDIVISION MTBJRTJRTSEPTEMBER 14, 2020ROCKFISH ROAD HOKE COUNTY, NORTH CAROLINA 143 Charlotte Avenue, Suite 104Sanford, North Carolina 27330(919) 777-6010 phonewww.jthomasengineering.comlicense no. C-338918 SEPT 2020: REVISED PER EC COMMENTSISSUEDFOR CONSTRUCTIONJ Thomas Engineering, Inc.civil engineering &planningJTE #: 20-010DDS#: 2019-238 OCT 2020: REVISED PER DRIVEWAY PERMIT COMMENT MOVED CURB TIE TO 6' FROM TRAVEL LANE21 OCT 2020: REVISED PER NCDOT COMMENTS, NCDEQPWS & NCDEQ STORMWATER PERMIT COMMENTSGRAYSTONE LANE50' PUBLIC R/W - 29.0' B-BNOTES:1.CONTRACTOR TO MAINTAIN 18" VERTICAL SEPARATION BETWEEN WATER AND STORM.2.WATER SHALL BE INSTALLED WITH 3.0 FT MIN COVER FROM CROWN OF PIPE TO FINISHGRADE.3.WATER LINE SHALL BE SDR21 AND INSTALLED PER HOKE COUNTY WATER SPECS.4.ALL STORM DRAINAGE PIPES SHALL BE RCP CLASS III UNLESS OTHERWISE NOTED.5.SEE SHEET C7 FOR STORM OUTFALL OUTLET PROTECTION SIZING.6.ALL FUTURE SEWER FORCE MAINS SHALL BE ENCASED WITH 6" STEEL CASING.7.ENCROACHMENTS ARE REQUIRED FOR PROPOSED ENCASEMENTS FOR FUTURE SEWERFORCE MAIN WITH IN THE DEDICATED NCDOT RIGHT OF WAY.302 LF - 30" RCP @ 0.7% (400-401A)CLASS III8"x8"x6" TEE8" GATE VALVE (1)6" GATE VALVE (1)3/4" WATER SERVICE (TYP)W/ 3/4" WATER METERNEWCASTLE COURTSEE SHEET C6FIRE HYDRANTASSEMBLY (TYP)STA: 10+84.32CRAFTSMAN COURTSEE SHEET C6HAYLOFT COURTSEE SHEET C6GRAYSTONE LANE8"x8"x6" TEE8" GATE VALVE (1)6" GATE VALVE (1)8"x8"x6" TEE8" GATE VALVE (1)6" GATE VALVE (1)FIRE HYDRANTASSEMBLY (TYP)STA: 10+89.82FIRE HYDRANTASSEMBLY (TYP)STA: 20+09.33FIRE HYDRANTASSEMBLY (TYP)STA: 24+15.1220' PERMANENTDRAINAGE EASEMENT (TYP)10' PRIVATE UTILITYEASEMENT (TYP)20' PRIVATEUTILITY/ACCESSEASEMENT (TYP)20' PERMANENTDRAINAGE EASEMENT (TYP)PERMANENTDRAINAGE EASEMENT (TYP)20' PERMANENT DRAINAGE EASEMENT (TYP)8" PVCWATER LINE (TYP)6" PVCWATER LINE (TYP)6" PVCWATER LINE (TYP)6" PVCWATER LINE (TYP)41 LF BORE & JACK8" PVC16" STEEL CASINGBORE PITRECEIVING PITOPEN CUT PAVEMENTAS REQUIREDTAPPING SLEEVE & VALVEW/WRAP AROUNDPER DETAILƒ%(1'ƒ%(1'ROCKFISH ROADPERMANENT CHANNEL (TYP)SEE SHEET C7DEADENDASSEMBLY8" GATE VALVE (1)60 LF 6" STEEL ENCASEMENTFOR FUTURE SEWERFORCEMAIN6" STEEL ENCASEMENT3.0' MIN COVERCONTINUE BOREDUNDERNEATHEX. WATER LINE50050100HORIZONTAL SCALE: 1" = 50'2505VERTICAL SCALE: 1" = 5'WCRWCRWCRWCRWCRPERMANENT DRAINAGEEASEMENT (TYP)10x70 NCDOTSITE TRIANGLE (TYP)10x70 NCDOTSITE TRIANGLE (TYP)10x70 NCDOTSITE TRIANGLE (TYP)ASPHALT TAPER8:1 (TYP)122 LF - 30" RCP @ 0.75% (401-401A)CLASS III212 LF - 30" RCP@ 0.5% (200-201A)CLASS IIINCDOT MAINTENANCEENDS AT R/W (TYP)NCDOT MAINTENANCEENDS AT R/WNCDOT MAINTENANCEENDS AT R/W (TYP)FEATHER CURB (TYP)49 LF 16" STEEL CASING8" PVCEXTENDED TO OUTSIDE R/WFEATHER CURB (TYP)ASPHALT TAPER8:1 (TYP)12 LF - 30" RCP@ 0.5% (201-201A)CLASS IIIPERMANENTDRAINAGE EASEMENT (TYP) 33+1830+0031+0032+0033+00W W W W W W W W W W W W W3456789WWWWWWWWWW C1X 199.7X 199.7X 201.0X 199.85EPX 199.66EPX 201.70EPX 200.40EP201.00 XEP199.27 XEPX 199.59EPCB 201CB 202CB 203ADI 204CB 206FES 207CB 208FPE=201.5FPE=201.0FPE=203.0FPE=203.0FPE=202.0FPE=201.5FPE=201.5200.01 XTOSX 200.0WMWMWMWM WMWM WMWMX 201.00EPX 201.5X 201.0X 201.0CB 203CB 205200200X 199.5200200JB 201A18018519019520020521021518018519019520020521021529+5030+00199.9200.031+00200.0200.032+00200.5201.033+00201.433+50199.64199.62199.94200.26200.58200.90201.25 -2.00%0.64%0.77%LOW POINT STA: 32+50.00LOW POINT EL= 200.90'PVI STA: 32+75.00PVI EL= 201.06'K= 374.8150.00' VCSD CATCH BASIN 206STA: 30+51.0 (12.0L)GRATE EL: 199.51INV OUT: 196.39SD CATCH BASIN 205STA: 30+51.0 (12.0R)GRATE EL: 199.51INV IN: 196.25 (206)INV OUT: 196.25SD CATCH BASIN 203STA: 30+13.0 (59.6R)GRATE EL: 199.00INV IN: 194.97 (208)INV OUT: 194.97SD CATCH BASIN 208STA: 30+13.0 (51.0R)GRATE EL: 199.67INV OUT: 195.8728 LF - 15" RCP @ 0.5% (205-206)CLASS III48 LF - 15" RCP @ 0.5% (204-205)CLASS III20 LF - 18" RCP@ 0.5% (203A-204)CLASS IIIC/L INTERSECTIONSTA: 30+00.00 = 16+90.93EL: 199.6418" MIN VERTICAL CLEARANCEBETWEEN STORM AND WATERC/L CUL-DE-SACSTA: 32+75.00EL: 201.080C/L END PAVEMENTSTA: 33+05.95EL: 201.3006" PVC - WATER LINE (SDR-21)3.0' MIN COVERF.H.EXISTING GROUND @ CLPROPOSED FINISHGRADE @ CLPRO. GRADEEX. GROUND18" MIN VERTICAL CLEARANCEBETWEEN CONDUIT AND WATER8" PVCSD DROP INLET 204(DOUBLE INLET)NCDOT 840.17-19STA: 30+34.9 (62.6R)GRATE EL: 199.00INV IN: 196.07 (205)INV OUT: 196.07SD CATCH BASIN 203ASTA: 30+13.0 (44.6R)GRATE EL: 198.90INV OUT: 195.0796 LF - 24" RCP@ 0.8% (203-208)CLASS IV2" PVC (SDR-21)6"X2" REDUCERWWWWWWWWWWWWWWWWWWWWWWW21 22 23 24 25 26 27 C1 199.00 XEP199. 5 2 X EPX 199.52 EP202.00 XEPCB 301X 19 9. 5 X 1 9 9 . 5 X 199 . 5 X 199.5 FPE=200.5 FPE=200.5 FPE=200.5 FPE=200.5 FPE=201.5FPE=201.5 FPE=201.5 X 201.0 X 200.0 WMWMWMWMWM 43+2840+0041+0042+0043+00X 20 1. 0 0 EP 2 0 1 . 1 X E P 200200200X 199.5 200200 20 0200 JB 301A 50+0051+0052+0053+0053+51WWWWWWWWWW W W W W W W W W W W W 1516171112131418WX 200.5X 203.33EP202.50 XEPX 202.50EP202.00 XEPX 202.0EPCB 401CB 403CB 404FPE=202.5FPE=202.5FPE=202.5FPE=202.5FPE=203.5FPE=204.0FPE=203.9FPE=202.7X 202.0X 2 0 1 . 8 X 201.8CB 402FES 405X 202.0WMWMWMW M WMWMWMWMWMWM WMWM X 201.00 EP203.00 XEPX 203.00EPDI 406DI 407X 203.0X 203.5X 202.0JB 401A18519019520020521021522018519019520020521021522039+5040+00200.0 200.0 41+00200.0 200.0 42+00200.0 200.0 43+00200.0 43+50201.49 200.99 200.68 200.36 200.05 199.71 199.24 -2.00%-0.63%-0.98%HIGH POINT STA: 42+25.00HIGH POINT EL= 199.89'PVI STA: 42+50.00PVI EL= 199.73'K= 143.5850.00' VCSD CATCH BASIN 301(DOUBLE INLET)STA:43+24.8 (0.0)GRATE EL: 199.00INV OUT: 196.00C/L INTERSECTION STA: 40+00.00 = 20+12.38 EL: 201.490 C/L CUL-DE-SAC STA: 42+95.37 EL: 199.28 C/L END PAVEMENT STA: 43+24.80 EL: 199.0006" PVC - WATER LINE (SDR-21)F.H.3.0' MIN COVEREXISTING GROUND @ CLPROPOSED FINISHGRADE @ CLPRO. GRADEEX. GROUND8" PVCSD FLARED END SECTION 300INV OUT: 195.2SD JUNCTION BOX 301ASTA:43+37.8 (0.0)RIM EL: 199.62INV IN:195.94 (301)INV OUT: 195.942" PVC (SDR-21)6"X2" REDUCER18018519019520020521021518018519019520020521021549+5050+00200.0 200.0 51+00200.0 200.1 52+00200.5 200.9 53+00201.5 202.1 54+00202.69 201.91 201.90 202.19 202.48 202.77 203.06 -2.00%0.58%LOW POINT STA: 50+75.02LOW POINT EL= 201.81'PVI STA: 50+53.00PVI EL= 201.63'K= 31.0180.00' VCSD CATCH BASIN 404STA: 50+75.0 (12.0R)GRATE EL: 201.55INV IN: 197.55 (406)INV OUT: 197.55SD CATCH BASIN 403STA: 50+75.0 (12.0L)GRATE EL: 201.55INV IN: 197.40 (404)INV IN: 197.40 (407)INV OUT: 197.4028.0 LF - 15" RCP @ 0.5% (403-404)CLASS III90.9 LF - 18" RCP@ 0.9% (401-403)CLASS III18" MIN VERTICAL CLEARANCEBETWEEN STORM AND WATERC/L END PAVEMENT STA: 53+46.70 EL: 203.3296" PVC - WATER LINE (SDR-21)F.H.C/L CUL-DE-SAC STA: 53+00.67 EL: 203.065 C/L END PAVEMENT STA: 50+00.00 = 22+21.90 EL: 202.686 3.0' MIN COVEREXISTING GROUND @ CLPROPOSED FINISHGRADE @ CLPRO. GRADEEX. GROUND8" PVCSD DROP INLET 406(DOUBLE INLET)NCDOT 840.17-19STA: 50+75.0 (35.0R)GRATE EL: 200.69INV OUT: 197.69SD DROP INLET 407(DOUBLE INLET)NCDOT 840.17-19STA: 50+75.0 (35.0L)GRATE EL: 200.55INV OUT: 197.5522.0 LF - 15" RCP @ 0.5% (403-407)CLASS III22.0 LF - 15" RCP @ 0.7% (404-406)CLASS III2" PVC (SDR-21)6"X2" REDUCERFile: C:\Users\DDS2\Desktop\Drafting and Design\2019\2019-23 Winchester Subdivsion\2020.04.22 - Winchester Subdivision CDs.dwg Print Date: 10/21/2020 PLAN/PROFILE PLAN/PROFILE PLAN/PROFILE HAYLOFT COURT NEWCASTLE COURT CRAFTSMAN COURT STA: 30+00 TO STA: 30+50 STA: 40+00 TO STA: 40+50 STA: 50+00 TO STA: 50+50C6Drawn by:Designed by:Reviewed by:Date:Scale:Sheet:Project Number:ofREVISIONS NORTH1"=50'20PROFESSIONAL ENGINEER'S SEAL WINCHESTER SUBDIVISION MTBJRTJRTSEPTEMBER 14, 2020ROCKFISH ROAD HOKE COUNTY, NORTH CAROLINA 143 Charlotte Avenue, Suite 104Sanford, North Carolina 27330(919) 777-6010 phonewww.jthomasengineering.comlicense no. C-338918 SEPT 2020: REVISED PER EC COMMENTSISSUEDFOR CONSTRUCTIONJ Thomas Engineering, Inc.civil engineering &planningJTE #: 20-010DDS#: 2019-238 OCT 2020: REVISED PER DRIVEWAY PERMIT COMMENT MOVED CURB TIE TO 6' FROM TRAVEL LANE21 OCT 2020: REVISED PER NCDOT COMMENTS, NCDEQPWS & NCDEQ STORMWATER PERMIT COMMENTSHAYLOFT COURT50' PUBLIC R/W - 29.0' B-B148 LF - 18" RCP@ 0.5% (300-301A)CLASS IIINEWCASTLE COURT50' PUBLIC R/W - 29.0' B-BCRAFTSMAN COURT50' PUBLIC R/W - 29.0' B-B8"x8"x6" TEE8" GATE VALVE (1)6" GATE VALVE (1)3/4" WATER SERVICE (TYP)W/ 3/4" WATER METERFIRE HYDRANTASSEMBLY (TYP)STA: 32+00.00 (24.0L)20' PERMANENTDRAINAGE EASEMENT (TYP)6" PVCWATER LINE (TYP)8" PVCWATER LINE (TYP)6" PVCWATER LINE (TYP)8" PVCWATER LINE (TYP)3/4" WATER SERVICE (TYP)W/ 3/4" WATER METER20' PERMANENTDRAINAGE EASEMENT (TYP)HAYLOFT COURTGRAYSTONE LANESEE SHEET C5GRAYSTONE LANESEE SHEET C5GRAYSTONE LANESEE SHEET C53/4" WATER SERVICE (TYP)W/ 3/4" WATER METER6" PVCWATER LINE (TYP)8" PVCWATER LINE (TYP)20' PERMANENTDRAINAGE EASEMENT (TYP)FIRE HYDRANTASSEMBLY (TYP)STA: 42+08.00 (24.0R)FIRE HYDRANTASSEMBLY (TYP)STA: 52+40.00 (24.0R)NOTES:1.CONTRACTOR TO MAINTAIN 18" VERTICAL SEPARATION BETWEEN WATER AND STORM.2.WATER SHALL BE INSTALLED WITH 3.0 FT MIN COVER FROM CROWN OF PIPE TO FINISHGRADE.3.WATER LINE SHALL BE SDR21 AND INSTALLED PER HOKE COUNTY WATER SPECS.4.ALL STORM DRAINAGE PIPES SHALL BE RCP CLASS III UNLESS OTHERWISE NOTED.5.SEE SHEET C7 FOR STORM OUTFALL OUTLET PROTECTION SIZING.6.ALL FUTURE SEWER FORCE MAINS SHALL BE ENCASED WITH 6" STEEL CASING.7.ENCROACHMENTS ARE REQUIRED FOR PROPOSED ENCASEMENTS FOR FUTURE SEWERFORCE MAIN WITH IN THE DEDICATED NCDOT RIGHT OF WAY.NEWCASTLE COURTCRAFTSMAN COURT20' PRIVATEUTILITY/ACCESSEASEMENT (TYP)20' PRIVATEUTILITY/ACCESSEASEMENT (TYP)10' PRIVATEUTILITY EASEMENT (TYP)PERMANENT CHANNEL (TYP)SEE SHEET C7NORTHNORTH90 LF 6" STEEL ENCASEMENTFOR FUTURE SEWERFORCEMAIN6" STEEL ENCASEMENT3.0' MIN COVER50050100HORIZONTAL SCALE: 1" = 50'2505VERTICAL SCALE: 1" = 5'10' PRIVATEUTILITYEASEMENT (TYP)WCRWCRWCRWCRWCRWCRWCRR48.0' R48.0' R 4 8 . 0 '20' PERMANENTDRAINAGE EASEMENT (TYP)PERMANENT DRAINAGE EASEMENT (TYP)SEE SHEET C7FOR CONTINUATION OF STORM10x70 NCDOTSITE TRIANGLE (TYP)10x70 NCDOTSITE TRIANGLE (TYP)10x70 NCDOTSITE TRIANGLE (TYP)20' PERMANENTDRAINAGE EASEMENT (TYP)122 LF - 24" RCP@ 0.5% (207-208)CLASS III12 LF - 18" RCP@ 0.5% (301-301A)CLASS III2" BLOWOFF (TYP)2" GATE VALVE (1)6"X2" REDUCER2" BLOWOFF (TYP)2" GATE VALVE (1)6"X2" REDUCER8"x8"x6" TEE8" GATE VALVE (1)6" GATE VALVE (1)8"x8"x6" TEE8" GATE VALVE (1)6" GATE VALVE (1)2" PVCWATER LINE (TYP)2" PVCWATER LINE (TYP)6"X2" REDUCER2" PVCWATER LINE (TYP)2" BLOWOFF (TYP)2" GATE VALVE (1) INV.= 1 9 6 . 3'INV.=1 9 5. 5 9'INV.=1 9 8. 6 5'INV.=1 9 8 . 4 6'GRAYSTONE LANEHAYL O F T C O U R T CRAFTSMAN COURT NEWCASTLE COURTW W W W W WWWWWWWWWWWWWWWWWWWWWWWWW23456715816917101112131418W W W W W WWWWWWW19202122232425262728OPENSPACE129W W W W W W W W W W30 W31323310A11AX 199.7X 199.7X 201 .0X 199.4X 199.6 X 201.0X 200.5X 2 0 0 . 1 0 E P X 199 .85EPX 2 0 0 . 2 8 E P X 199.66EPX 201.70EPX 2 0 0 . 4 0 EP 20 1 . 0 0 X E P X 203.33EP202.50 XEPX 202.50EP199.00 XEP199.52 XEPX 199.52EP202.00 X EP X 202.0EP199.27 XEPX 199.59EPX 201 .43EPX 20 1 . 5 1 EP X 200.45EPX 2 0 0 . 4 5 EP X 2 0 0 . 3 0 EP X 200.30EPX 198 .5 FES 10 1 FES 10 0 FES 2 0 0 CB 201CB 202CB 203ADI 204CB 20 6 FES 2 0 7CB 301CB 401FES 300 FES 400 CB 403 CB 404 CB 208X 19 9 . 5 X 199.5X 199.5X 199.5X 199.5X 199.5X 194.0X 2 0 1 . 0 X 2 0 1 . 0 FLUME 2 FLUME 1FPE=200.5200200FPE=200.5FPE=200.5FPE=200.5FPE=201.5FPE=201.5FPE=201.5FPE=201.5FPE=202.5FPE=202.5FPE=202.5FPE=202.5FPE=203.5FPE=204.0FPE=203.9FPE=202.7FPE=202.0FPE=201.5FPE=201.0FPE=203.0FPE=203.0FPE=202.0FPE=201.5FPE=201.5FPE=201.5FPE=201.5FPE=200.5FPE=200.5FPE=201.5FPE=201.5FPE=201.5FPE=201.5FPE=201.5X 201.0X 2 0 2 . 0 X 201.8 X 201.8CB 402FES 405 X 200.26TOS200.01 XTOSX 199.0X 200.0X 201.0H.P.X 199.0X 202.0X 194.0X 191.8ROCKFISH ROAD - SR 1403SWEET WILLIAM WAY - SR 1774X 20 1 . 0 0 EP201.1 XEPX 2 0 1 . 0 0 EP 203.00 XEPX 203 .00EP2 0 0 200 205 19819819819 8 1 9 9 199 201 201 202 202 203 203 204 197 197198199DI 406 DI 407 X 203.0X 203.5X 202.5X 201.5X 201.0X 201.0X 202.0CB 203CB 20 5X 201.0X 201.0200 2 0 0 200200200195195 195195200 X 203.5X 20 1 . 0X 199.5X 199.5200200200200 20 0 200200200200X 20 1 . 0 JB 401AJB 201AJB 301AX 2 0 0 . 1 0 E P X 1 9 9 . 8 5 E P X 2 0 0 . 2 8 E PX 199 .66EPX 200.26TOS200.01 XTOSX 199 .5 File: C:\Users\DDS2\Desktop\Drafting and Design\2019\2019-23 Winchester Subdivsion\2020.04.22 - Winchester Subdivision CDs.dwg Print Date: 10/21/2020 OVERALL GRADING AND DRAINAGE PLANC7Drawn by:Designed by:Reviewed by:Date:Scale:Sheet:Project Number:ofREVISIONS 80080160SCALE: 1" = 80'40NORTH1"=80'20PROFESSIONAL ENGINEER'S SEAL WINCHESTER SUBDIVISION MTBJRTJRTSEPTEMBER 14, 2020ROCKFISH ROAD HOKE COUNTY, NORTH CAROLINA 143 Charlotte Avenue, Suite 104Sanford, North Carolina 27330(919) 777-6010 phonewww.jthomasengineering.comlicense no. C-338918 SEPT 2020: REVISED PER EC COMMENTSISSUEDFOR CONSTRUCTIONJ Thomas Engineering, Inc.civil engineering &planningJTE #: 20-010DDS#: 2019-238 OCT 2020: REVISED PER DRIVEWAY PERMIT COMMENT MOVED CURB TIE TO 6' FROM TRAVEL LANE21 OCT 2020: REVISED PER NCDOT COMMENTS, NCDEQPWS & NCDEQ STORMWATER PERMIT COMMENTSPERCENT IMPERVIOUS =15.2%DISTURBED AREA =29.1 ACNOTES:1.EXISTING TOPO PER NCDOT LIDAR TYPICAL ACCURACY 1.5 +/-.2.CONTRACTOR IS RESPONSIBLE FOR PROTECTING EXISTING UTILITIES WHILE WORKING. EXISTINGUNDERGROUND UTILITIES SHOWN HERE SHALL BE CONSIDERED APPROXIMATE. OTHER UTILITIES MAY BEPRESENT. CONTRACTOR SHALL CALL 'ONE CALL MARKED BY 811 ONE CALL PRIOR TO BEGINNING WORK.3.BORROW / DISPOSAL SITES MUST COMPLY WITH NCDEQ RULES FOR LAND DISTURBANCE.4.STORM DRAIN SYSTEM SHALL BE CONSTRUCTED TO NCDOT STANDARDS. STORM DRAINAGE PIPE TO BEREINFORCED CONCRETE (CLASS III UNLESS SPECIFIED OTHERWISE).5.CONTRACTOR TO VERIFY FINAL ELEVATIONS WITH ACTUAL FIELD CONDITIONS.6.CONTRACTOR TO MAINTAIN POSITIVE DRAINAGE ON LOTS AWAY FROM BUILDING PAD.7.ALL PAD ELEVATIONS ARE SET 0.5 FEET ABOVE BACK OF CURB AT CENTER OF LOT. CONTRACTOR MAYADJUST PAD ELEVATIONS BUT MUST MAINTAIN POSITIVE DRAINAGE AWAY FROM PAD.8.MAXIMUM BUILDING PAD ELEVATION ABOVE BACK OF CURB SHALL BE 1.5 FEET AND MINIMUM BUILDINGPAD ELEVATION ABOVE BACK OF CURB SHALL BE 0.5 FEET.9.SEE SHEET C8 AND C9 FOR EROSION CONTROL PLAN AND NOTES.10.PERMANENT CHANNELS #3-5 DESIGNED PER NCDEQ POST STORMWATER RULE 15A NCAC 02H.1003 (2c) ASVEGETATIVE CONVEYANCE SWALE.11.THE DEVELOPMENT HAS BEEN DESIGNED A LOW DENSITY DEVELOPMENT PER NCDEQ POST STORMWATERRULE 15A NCAC 02H.1003. IMPERVIOUS AREA SHALL BE LESS THAN 24%.PC #1PC #2PC #3PC #4PC #5PC #6GRASSSWALE (TYP)GRASSSWALE (TYP)GRASSSWALE (TYP)MAIL KIOSK (GRADING PLAN)SCALE: 1"=30'EX. DRAINAGE SWALEOUTLET PROTECTION #100La=8.0'W=6.0'd=12"STONE Ø= CLASS A RIP RAPOUTLET PROTECTION #200La=18.0'W=9.0'd=18"STONE Ø= CLASS B RIP RAPOUTLET PROTECTION #300La=6.0'W=4.5'd=12"STONE Ø= CLASS A RIP RAPOUTLET PROTECTION #400La=15.0'W=7.5'd=18"STONE Ø= CLASS B RIP RAPLIMIT OF DISTURBANCE (TYP)ROCKFISH ROADTIE PC#3TO BOTTOM OF EXISTINGDRAINAGE SWALETIE PC#5TO BOTTOM OF EXISTINGDRAINAGE SWALEEX. DRAINAGE SWALEPERMANENT CHANNEL SCHEDULEDIVERSIONNO.DRAINAGEAREA (AC)DEPTH - D (FT)SIDE SLOPEZAVE.SLOPE (%)TEMPORARYLININGPC#1PC#211.6 25 - YEARFLOW (CFS)39.12.040.510.518.41.040.5LENGTH (FT)2401046BOTTOM WIDTH - BW (FT)22N.A.G. S75BNPC#35.251.62.050.14806PC#40.98.13.050.12906SHEAR(LB/FT^2)0.430.390.100.42N.A.G. S75BNN.A.G. S75BNN.A.G. S75BNPC#58.357.43.050.655030.68N.A.G. S75BNPERMANENTLININGFESCUEFESCUEFESCUEFESCUEFESCUEPC#616.831.93.040.635020.38N.A.G. S75BNFESCUE INV.=1 9 6. 3' INV.= 1 9 5 . 5 9'30' ACCESS EASEMENT (DB 226 PG 80)RESE R V E D A D D I TI O N A L 1 0' R/ W PC 3 S L I D E 3 - 4 5 , M A P 0 0 8SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSF SF SF SF SFSFSTOCKPILE/MATERIALAREATD# 1CULVERT #172 LF 24" RCP @ 0.5%TD# 1TD# 1TD# 1TD# 2TD# 2TD# 3TD# 3TD# 3TD# 4TD# 4TD# 4TD# 4TD# 5 (CW)TD# 5 (CW)TD# 5 (CW)TD# 5 (CW)TD# 5 (CW)TD# 5 (CW)TD# 6 (CW)TD# 6 (CW)TD# 6 (CW)TD# 6 (CW)TD# 6 (CW)TD# 6 (CW)TD# 6 (CW)INV IN=198.0INV IN=197.6SB #1BAFFLE (TYP)SKIMMERRISERBARRELOUTLET PROTECTION #1La=9.0'W=4.5'd=18"STONE Ø= CLASS B RIP RAPSKIMMERBAFFLE (TYP)TD #1TD #6(CLEANWATER)TD #5(CLEANWATER)TD #4TD #3TD #2TD #6(CLEANWATER)SF SF SFSK #2SILT FENCE (TYP)SILT FENCE (TYP)SILT FENCE (TYP)SILT FENCE (TYP)EX. DRAINAGE SWALE (TYP)SILT FENCE OUTLET (TYP)SILT FENCE OUTLET (TYP)SILT FENCE OUTLET (TYP)SILT FENCE OUTLET (TYP)CULVERTINLET PROTECTION (TYP)25'x100CONSTRUCTION ENTRANCE (TYP)CONCRETE WASHOUTLIMIT OF DISTURBANCE (TYP)5' BERM (TYP)DAYLIGHT SKIMMERINTO EX. DRAINAGE SWALETD #3ROCK ENTRANCECLASS A RIP RAPd=12"MATCH CHANNEL WIDTHROCK ENTRANCECLASS A RIP RAPd=12"MATCH CHANNEL WIDTH2 0 0 200 205 19819819819 8 1 9 9 199 201 2 0 1 202 202 203 204 2 0 0 197 19719819 8 1991 9 9 OUTLET PROTECTION #100La=8.0'W=6.0'd=12"STONE Ø= CLASS A RIP RAPSF SF SF SF SF SF SF SF SF SF SF SF SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFNOTE:ALL DIVERSIONS AND PERMANENT CHANNELSIMMEDIATELY INSTALL MATTING PER TEMPORARY/PERMANENT LINERINSTALL NAG P300LAST 150 FT OF TD#5INSTALL NAG P300LAST 150 FT OF TD#6INSTALL NAG P300LAST 150 FT OF TD#6File: C:\Users\DDS2\Desktop\Drafting and Design\2019\2019-23 Winchester Subdivsion\2020.04.22 - Winchester Subdivision CDs.dwg Print Date: 10/21/2020 EROSION CONTROL PLAN - INITIAL CONSTRUCTIONC8Drawn by:Designed by:Reviewed by:Date:Scale:Sheet:Project Number:ofREVISIONS NORTH1"=80'20PROFESSIONAL ENGINEER'S SEAL WINCHESTER SUBDIVISION MTBJRTJRTSEPTEMBER 14, 2020ROCKFISH ROAD HOKE COUNTY, NORTH CAROLINA 143 Charlotte Avenue, Suite 104Sanford, North Carolina 27330(919) 777-6010 phonewww.jthomasengineering.comlicense no. C-338918 SEPT 2020: REVISED PER EC COMMENTSISSUEDFOR CONSTRUCTIONJ Thomas Engineering, Inc.civil engineering &planningJTE #: 20-010DDS#: 2019-238 OCT 2020: REVISED PER DRIVEWAY PERMIT COMMENT MOVED CURB TIE TO 6' FROM TRAVEL LANE21 OCT 2020: REVISED PER NCDOT COMMENTS, NCDEQPWS & NCDEQ STORMWATER PERMIT COMMENTS80080160SCALE: 1" = 80'40TEMPORARY DIVERSION SCHEDULEDIVERSIONNO.DRAINAGEAREA (AC)DEPTH - D (FT)SIDE SLOPEZAVE.SLOPE (%)LININGTD#1TD#222.7 25 - YEARFLOW (CFS)48.82.530.51.24.31.530.5LENGTH (FT)850250BOTTOM WIDTH - BW (FT)00N.A.G. S75BNTD#32.17.51.530.53500TD#42.58.91.530.56800SHEAR(LB/FT^2)0.590.230.290.36N.A.G. S75BNN.A.G. S75BNN.A.G. S75BNTEMPORARY DIVERSION DITCHROCK CHECK DAMSSILT FENCESEDIMENT BASINEROSION CONTROL LEGENDTOP OF BERMBAFFLESWIEROUTLET PROTECTIONSILT FENCE OUTLETSFINLET PROTECTIONCONSTRUCTION SEQUENCE - INITIAL CONSTRUCTION PHASE1.EROSION AND SEDIMENT CONTROL (E&SC) PERMIT AND A CERTIFICATE OF COVERAGE (COC) MUST BE OBTAINED BEFORE ANY LANDDISTURBING ACTIVITIES OCCUR. A COPY OF THE E&SC PERMIT, THE COC, AND A HARD COPY OF THE PLAN MUST BE KEPT ON SITE,PREFERABLY IN A PERMITS BOX, AND ACCESSIBLE DURING INSPECTION.” THE COC CAN BE OBTAINED BY FILLING OUT THEELECTRONIC NOTICE OF INTENT (E-NOI) FORM AT DEQ.NC.GOV/NCG01. PLEASE NOTE, THE E-NOI FORM MAY ONLY BE FILLED OUTONCE THE PLANS HAVE BEEN APPROVED.2.SELF-INSPECTIONS FOR EROSION AND SEDIMENTATION CONTROL MEASURES ARE TO BE PERFORMED AT LEAST ONCE EVERY SEVENCALENDAR DAYS AND WITHIN 24 HOURS OF EVERY RAIN EVENT OF GREATER THAN 1 INCH. ANY NEEDED REPAIRS SHALL BE MADEIMMEDIATELY TO MAINTAIN MEASURES AS DESIGNED. ALL ESC MEASURES SHALL BE MAINTAINED AS SPECIFIED IN THECONSTRUCTION DETAILS ON THIS PLAN. A RAIN GAUGE SHALL BE INSTALLED AT THE PROJECT SITE FOR MONITORING.3.CONTACT THE DEMLR FAYETTEVILLE REGIONAL OFFICE AT LEAST 48 HOURS PRIOR TO COMMENCING THE LAND DISTURBINGACTIVITY (910) 433-3300.4.CONTRACTOR TO MAINTAIN EROSION CONTROL DEVICES ACCORDING TO MAINTENANCE PLAN THROUGHOUT CONSTRUCTION.5.INSTALL CONSTRUCTION ENTRANCE AT ROCKFISH ROAD W/CULVERT #1.6.INSTALL SILT FENCE AS SHOWN ON PLANS. INSTALL SILT FENCE OUTLETS WHERE SHOWN ON PLANS AND OTHER AREAS ALONG THESILT FENCE PERIMETER WHERE CONCENTRATED FLOWS EXIST.7.INSTALL SKIMMER/SEDIMENT BASIN #1, 2. STABILIZE AND SEED ALL SLOPES IMMEDIATELY. ONLY CLEAR AS NECESSARY TOINSTALL BASINS. MAINTAIN SILT FENCE AND SILT FENCE OUTLETS DOWN STREAM UNTIL GOOD GROUND COVER IS ESTABLISHED8.INSTALL TEMPORARY CLEANWATER DIVERSIONS #5 &6. IMMEDIATELY STABILIZE AND SEED ALL SLOPES IMMEDIATELY. MAINTAINSILT FENCE AND SILT FENCE OUTLETS DOWN STREAM UNTIL TEMPORARY/PERMANENT LINING.9.INSTALL SILT FENCE PER PLAN BELOW ALL PERMANENT/TEMPORARY DIVERSIONS AND BASIN/TRAPS W/ SILT FENCE OUTLETS INLOW AREAS PER PLAN.10.INSTALL TEMPORARY DIVERSIONS #1-4. IMMEDIATELY STABILIZE AND SEED ALL SLOPES IMMEDIATELY. MAINTAIN SILT FENCE ANDSILT FENCE OUTLETS DOWN STREAM UNTIL TEMPORARY/PERMANENT LINING.11.STRIP TOPSOIL AS REQUIRED. BEGIN ROUGH GRADING ROADS AND LOTS.12.CONTRACTOR TO STABILIZE AND SEED ALL DENUDED AREAS IF LAND DISTURBING ACTIVITIES WILL NOT COMMENCEAGAIN IN THAT AREA WITHIN 7 CALENDAR DAYS OR 14 CALENDAR DAYS. REFERENCE DEMLR GROUND STABILIZATIONTIME FRAMES.13.PERMANENT GROUNDCOVER WILL BE PROVIDED FOR ALL DISTURBED AREAS WITHIN 15 WORKING DAYS OR NO MORETHAN 90 CALENDAR DAYS(WHICHEVER IS SHORTER).14.SEE SHEET 9 FOR CONSTRUCTION SEQUENCE - FINAL CONSTRUCTION PHASE.DISTURBED AREA =29.1 ACTD#523.349.92.530.5165000.59N.A.G. S75BNTD#67.918.52.030.5127000.41N.A.G. S75BNNOTES1.LIMIT OF DISTURBANCE = 29.1 AC +/-. NCDEQ EROSION CONTROL PERMIT REQUIRED.2.OFF-SITE BORROW / WASTE SITES MUST COMPLY WITH NCDEQ RULES ANDREGULATIONS FOR LAND DISTURBANCE.3.CONTRACTOR MAY NEED TO FIELD ADJUST PROPOSED SEDIMENT BASIN ELEVATIONSTO FIT ACTUAL FIELD CONDITIONS.4.CONTRACTOR TO KEEP ALL CONSTRUCTION/STORAGE OPERATIONS WITHIN LIMIT OFDISTURBANCE.5.NO STREAMS OR WETLANDS HAS BEEN IDENTIFIED BY THE OWNER AS BEING WITHINTHE LIMITS OF DISTURBANCE.6.CUT/FILL SLOPES SHALL BE 3:1 MAXIMUM.7.THIS PROPERTY IS LOCATED IN THE CAPE FEAR RIVER BASIN. SITE DRAINS TO GULLYBRANCH, A CLASS 'B' WATERS.8.THE SOIL TYPE (ACCORDING TO THE NRCS MAP) IS NoA - NORFOLK LOAMY, Ra - RAINSSANDY LOAM, WaB - WAGRAM LOAMY, GoA - GOLDSBORO LOAMY. THIS SOIL TYPE ISHYDROLOGIC GROUP 'A'.9.ROLLED EROSION CONTROL PRODUCT (RECP) SHALL BE NORTH AMERICAN GREEN(N.A.G.) PRODUCTS OR EQUAL.ROCKFISH ROAD - SR#1406SWEET WILLIAM WAY - SR 1774TEMPORARY SKIMMER BASIN SCHEDULENAMEDRAINAGEAREA(AC)10 YEARFLOW(CFS)S.A.REQUIRED(SF)S.A.PROVIDED(SF)DIMS. @ BASINBOTTOM(FT)DIMS.@ TOP OFSTORAGE(FT)VOLUMEREQUIRED(CF)VOLUMEPROVIDED(CF)DEPTH(FT)BASIN BOTTOMELEV(FT)TOP OFSTORAGE ELEV(FT)WEIR ELEV(FT)TOP OF BERMELEV(FT)WEIR LENGTH(FT)SKIMMER PIPESIZE (IN)ORIFICEDIAMETER (IN)SKB #25.521.97,9458,19246 x 11064 x 1289,90019,8783.0193.0196.0196.0197.01541.4TEMPORARY SEDIMENT BASIN SCHEDULENAMEDRAINAGEAREA(AC)10 YEARFLOW(CFS)S.A.REQUIRED(SF)S.A.PROVIDED(SF)DIMS. @ BASINBOTTOM(FT)DIMS.@ TOP OFSTORAGE(FT)VOLUMEREQUIRED(CF)VOLUMEPROVIDED(CF)DEPTH(FT)BASIN BOTTOMELEV(FT)TOP OFSTORAGE ELEV(FT)WEIR ELEV(FT)TOP OF BERMELEV(FT)WEIR LENGTH(FT)SKIMMER PIPESIZE (IN)ORIFICEDIAMETER (IN)SB #125.536.617,30417,78753 x 20777 x 23145,90057,5164.0193.0197.0197.5199.03562.7RISER (IN)24BARREL (IN)18CONCRETEBASE (FT)5.5X5.5X1 INV.=1 9 6. 3' INV.= 1 9 5 . 5 9'GRAYSTONE LANEHAYL O F T C O U R T CRAFTSMAN COURT NEWCASTLE COURTX 199.7X 199.7X 201 .0X 199.4X 199.6 X 201.0X 200.5X 2 0 0 . 1 0 E P X 199 .85EPX 2 0 0 . 2 8 EP X 199.66EPX 201.70EPX 2 0 0 . 4 0 E P 20 1 . 0 0 X E P X 203.33EP202.50 XEPX 202 .50EP199.00 XEP199.52 XEPX 199.52EP202.00 X EP X 202.0EP199.27 XEPX 199.59EPX 201 . 43EP X 20 1 . 5 1 EP X 200.45EPX 2 0 0 . 4 5 EP X 2 0 0 . 3 0 EP X 200.30EPX 198 .5 FES 10 1 FES 10 0 FES 2 0 0 CB 201CB 202CB 203ADI 204CB 20 6 FES 2 0 7CB 301CB 401FES 300 FES 400 CB 403 CB 404 CB 208X 1 99 . 5 X 199.5X 199.5X 199.5X 199.5X 199.5X 194.0X 2 0 1 . 0 X 2 0 1 . 0 FLUME 2 FLUME 1FPE=200.5200200FPE=200.5FPE=200.5FPE=200.5FPE=201.5FPE=201.5FPE=201.5FPE=201.5FPE=202.5FPE=202.5FPE=202.5FPE=202.5FPE=203.5FPE=204.0FPE=203.9FPE=202.7FPE=202.0FPE=201.5FPE=201.0FPE=203.0FPE=203.0FPE=202.0FPE=201.5FPE=201.5FPE=201.5FPE=201.5FPE=200.5FPE=200.5FPE=201.5FPE=201.5FPE=201.5FPE=201.5FPE=201.5X 201.0X 2 0 2 . 0 X 20 1. 8 X 201 .8CB 402FES 405 X 200.26TOS200.01 XTOSX 199.0X 200.0X 201.0H.P.X 199.0X 202.0SFSFSFSFSFSFSFSFSFSFSFSFSFSF SFSFSFSF SF SF SF SF SFSFSFSFSFSFSFSFSFSFSF SF SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSF SF SF SF SFSFSF SF SFX 194.0X 191.8SB #1BAFFLE (TYP)SKIMMERRISERBARRELOUTLET PROTECTION #1La=9.0'W=4.5'd=18"STONE Ø= CLASS B RIP RAPTD# 1TD# 1EX. DRAINAGE SWALE (TYP)SILT FENCE (TYP)TD #1TD# 1TD# 1TD #6(CLEANWATER)SILT FENCE (TYP)SILT FENCE (TYP)TD# 6 (CW)TD# 6 (CW)TD #6(CLEANWATER)TD# 6 (CW)TD# 6 (CW)TD# 6 (CW)TD# 6 (CW)TD# 5 (CW)TD# 5 (CW)TD# 5 (CW)TD# 5 (CW)TD# 4TD# 4TD# 5 (CW)TD #4TD# 4TD# 4SK #2TD #3TD# 3 TD# 3TD #2TD# 2TD# 2BAFFLE (TYP)SKIMMERTD# 3TD# 5 (CW)STOCKPILE/MATERIALAREAPERMANENTSWALES (TYP)PC #3PC #4PC #5PC #1PC #2INLET PROTECTION (TYP)INLET PROTECTION (TYP)SILT FENCE OUTLET (TYP)SILT FENCE OUTLET (TYP)CULVERTINLET PROTECTION (TYP)25'x100CONSTRUCTION ENTRANCE (TYP)CONCRETE WASHOUTTD #5(CLEANWATER)CONVERT TO PC#6ROCKFISH ROAD - SR 1403LIMIT OF DISTURBANCE (TYP)SWEET WILLIAM WAY - SR 1774X 201 .0 0 EP201.1 XEPX 2 0 1 . 0 0 E P 203.00 XEPX 203 .00EPROCK ENTRANCECLASS A RIP RAPd=12"MATCH CHANNEL WIDTHROCK ENTRANCECLASS A RIP RAPd=12"MATCH CHANNEL WIDTH2 0 0 200 205 19819819819 8 1 9 9 199 201 2 0 1 202 202 203 204 2 0 0 197 19719819 8 1991 9 9 2 0 1 DI 406 DI 407 X 203.0X 203.5X 202.5X 201.5X 201.0X 201.0X 202.0CB 203CB 20 5X 201.0X 201.0200 2 0 0 200200200195 195195195200 X 203.5X 20 1 . 0X 199.5X 199.5200200200200 200 200200200200X 20 1 . 0 SF SF SF SF SF SF SF SF SF SF SF SF SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSILT FENCE (TYP)SILT FENCE (TYP)OUTLET PROTECTION #2La=7.5'W=3.5'd=12"STONE Ø= CLASS A RIP RAPPC #3 & PC #4MUST BE MATTED PER TEMPORARY LINERIMMEDIATELY UPON BASIN REMOVALPC #5MUST BE MATTED PER TEMPORARY LINERIMMEDIATELY UPON BASIN REMOVALROCK INLET PROTECTIONROCK INLET PROTECTIONROCK INLET PROTECTIONNOTE:ALL DIVERSIONS AND PERMANENT CHANNELSIMMEDIATELY INSTALL MATTING PER TEMPORARY/PERMANENT LINERINSTALL NAG P300LAST 150 FT OF TD#5INSTALL NAG P300LAST 150 FT OF TD#6INSTALL NAG P300LAST 150 FT OF TD#6JB 401AJB 201AJB 301AFile: C:\Users\DDS2\Desktop\Drafting and Design\2019\2019-23 Winchester Subdivsion\2020.04.22 - Winchester Subdivision CDs.dwg Print Date: 10/21/2020 EROSION CONTROL PLAN - FINAL CONSTRUCTIONC9Drawn by:Designed by:Reviewed by:Date:Scale:Sheet:Project Number:ofREVISIONS NORTH1"=80'20PROFESSIONAL ENGINEER'S SEAL WINCHESTER SUBDIVISION MTBJRTJRTSEPTEMBER 14, 2020ROCKFISH ROAD HOKE COUNTY, NORTH CAROLINA 143 Charlotte Avenue, Suite 104Sanford, North Carolina 27330(919) 777-6010 phonewww.jthomasengineering.comlicense no. C-338918 SEPT 2020: REVISED PER EC COMMENTSISSUEDFOR CONSTRUCTIONJ Thomas Engineering, Inc.civil engineering &planningJTE #: 20-010DDS#: 2019-238 OCT 2020: REVISED PER DRIVEWAY PERMIT COMMENT MOVED CURB TIE TO 6' FROM TRAVEL LANE21 OCT 2020: REVISED PER NCDOT COMMENTS, NCDEQPWS & NCDEQ STORMWATER PERMIT COMMENTS80080160SCALE: 1" = 80'40TEMPORARY DIVERSION DITCHROCK CHECK DAMSSILT FENCESEDIMENT BASINEROSION CONTROL LEGENDTOP OF BERMBAFFLESWIEROUTLET PROTECTIONSILT FENCE OUTLETSFINLET PROTECTIONPERMANENT CHANNEL SCHEDULEDIVERSIONNO.DRAINAGEAREA (AC)DEPTH - D (FT)SIDE SLOPEZAVE.SLOPE (%)TEMPORARYLININGPC#1PC#21.7 25 - YEARFLOW (CFS)21.62.040.58.915.61.040.5LENGTH (FT)2401046BOTTOM WIDTH - BW (FT)00N.A.G. S75BNPC#35.251.62.040.14806PC#40.98.13.040.12900SHEAR(LB/FT^2)0.430.390.100.42N.A.G. S75BNN.A.G. S75BNN.A.G. S75BNCONSTRUCTION SEQUENCE - FINAL CONSTRUCTION PHASEPHASE 1 & 21.EROSION AND SEDIMENT CONTROL (E&SC) PERMIT AND A CERTIFICATE OF COVERAGE (COC) MUST BE OBTAINEDBEFORE ANY LAND DISTURBING ACTIVITIES OCCUR. A COPY OF THE E&SC PERMIT, THE COC, AND A HARD COPY OF THEPLAN MUST BE KEPT ON SITE, PREFERABLY IN A PERMITS BOX, AND ACCESSIBLE DURING INSPECTION.” THE COC CAN BEOBTAINED BY FILLING OUT THE ELECTRONIC NOTICE OF INTENT (E-NOI) FORM AT DEQ.NC.GOV/NCG01. PLEASE NOTE,THE E-NOI FORM MAY ONLY BE FILLED OUT ONCE THE PLANS HAVE BEEN APPROVED.2.SELF-INSPECTIONS FOR EROSION AND SEDIMENTATION CONTROL MEASURES ARE TO BE PERFORMED AT LEAST ONCEEVERY SEVEN CALENDAR DAYS AND WITHIN 24 HOURS OF EVERY RAIN EVENT OF GREATER THAN 1 INCH. ANY NEEDEDREPAIRS SHALL BE MADE IMMEDIATELY TO MAINTAIN MEASURES AS DESIGNED. ALL ESC MEASURES SHALL BEMAINTAINED AS SPECIFIED IN THE CONSTRUCTION DETAILS ON THIS PLAN. A RAIN GAUGE SHALL BE INSTALLED AT THEPROJECT SITE FOR MONITORING.3.SEE SHEET C8 FOR CONSTRUCTION SEQUENCE - INITIAL CONSTRUCTION PHASE.4.INSTALL PERMANENT CHANNELS 1-6. STABILIZE AND SEED ALL SLOPES IMMEDIATELY. ONLY CLEAR AS NECESSARY TOINSTALL DIVERSIONS. MAINTAIN SILT FENCE AND SILT FENCE OUTLETS DOWN STREAM UNTIL TEMPORARY/PERMANENTLINING, AND GOOD GROUND COVER IS ESTABLISHED.4.MAINTAIN TEMPORARY DIVERSIONS STILL IN-PLACE FROM INITIAL PHASE UNTIL DRAINAGE IS DIVERTED INTO THEPROPOSED STORM SYSTEM WITH INLET PROTECTION OR IS CONVEYED BY PERMANENT CHANNEL.5.FINE GRADE ROAD AND LOTS MAINTAINING POSITIVE DRAINAGE. PREVENT ANY CHANNELIZED FLOW TO SILT FENCE.6.SEED AND STABLIZE ALL DENUDED AREAS.7.INSTALL PROPOSED STORM DRAINAGE WITH INLET PROTECTION.8.INSTALL PERMANENT SWALES TO ENSURE POSITIVE DRAINAGE FROM LOTS TO DROP INLETS.9.MAINTAIN SILT FENCE AFTER MAJOR RAIN EVENTS.10.WHEN THE SITE IS FULLY STABILIZED, REMOVE TEMPORARY EROSION CONTROL MEASURES. DEWATER BASINS ANDUTILITY TRENCHES AS NEEDED THROUGH SILT BAG. STABILIZE AND SEED ALL SLOPES IMMEDIATELY. ONLY CLEAR ASNECESSARY TO INSTALL DIVERSIONS. MAINTAIN SILT FENCE AND SILT FENCE OUTLETS DOWN STREAM UNTILTEMPORARY/PERMANENT LINING, AND GOOD GROUND COVER ON FILL SLOPES IS ESTABLISHED. 11. GRADE PERMANENT SWALES #3,4,5 TO FINAL GRADE ONCE BASINS ARE REMOVED. SWALES MUST BE MATTED PER TEMPORARY LINER IMMEDIATELY UPON BASIN REMOVAL.12.WHEN THE PROJECT IS COMPLETE, THE PERMITTEE SHALL CONTACT DEMLR TO CLOSE OUT THE E&SC PLAN. AFTERDEMLR INFORMS THE PERMITTEE OF THE PROJECT CLOSE OUT, VIA INSPECTION REPORT, THE PERMITTEE SHALL VISITDEQ.NC.GOV/NCG01 TO SUBMIT AN ELECTRONIC NOTICE OF TERMINATION (E-NOT). A $100 ANNUAL GENERAL PERMITFEE WILL BE CHARGED UNTIL THE E-NOT HAS BEEN FILLED OUT.13.CONTRACTOR TO STABILIZE AND SEED ALL DENUDED AREAS IF LAND DISTURBING ACTIVITIES WILL NOTCOMMENCE AGAIN IN THAT AREA WITHIN 7 CALENDAR DAYS OR 14 CALENDAR DAYS. REFERENCE DEMLRGROUND STABILIZATION TIME FRAMES.14.PERMANENT GROUNDCOVER WILL BE PROVIDED FOR ALL DISTURBED AREAS WITHIN 15 WORKING DAYS ORNO MORE THAN 90 CALENDAR DAYS(WHICHEVER IS SHORTER).15.WHEN THE PROJECT IS COMPLETE, THE PERMITTEE SHALL CONTACT DEMLR TO CLOSE OUT THE E&SC PLAN. AFTERDEMLR INFORMS THE PERMITTEE OF THE PROJECT CLOSE OUT, VIA INSPECTION REPORT, THE PERMITTEE SHALL VISITDEQ.NC.GOV/NCG01 TO SUBMIT AN ELECTRONIC NOTICE OF TERMINATION (E-NOT). A $100 ANNUAL GENERAL PERMITFEE WILL BE CHARGED UNTIL THE E-NOT HAS BEEN FILLED OUT.PC#58.357.43.040.655000.68N.A.G. S75BNPERMANENTLININGFESCUEFESCUEFESCUEFESCUEFESCUETEMPORARY SKIMMER BASIN SCHEDULENAMEDRAINAGEAREA(AC)10 YEARFLOW(CFS)S.A.REQUIRED(SF)S.A.PROVIDED(SF)DIMS. @ BASINBOTTOM(FT)DIMS.@ TOP OFSTORAGE(FT)VOLUMEREQUIRED(CF)VOLUMEPROVIDED(CF)DEPTH(FT)BASIN BOTTOMELEV(FT)TOP OFSTORAGE ELEV(FT)WEIR ELEV(FT)TOP OF BERMELEV(FT)WEIR LENGTH(FT)SKIMMER PIPESIZE (IN)ORIFICEDIAMETER (IN)SKB #25.521.97,9458,19246 x 11064 x 1289,90019,8783.0193.0196.0196.0197.01541.4TEMPORARY DIVERSION SCHEDULEDIVERSIONNO.DRAINAGEAREA (AC)DEPTH - D (FT)SIDE SLOPEZAVE.SLOPE (%)LININGTD#1TD#222.7 25 - YEARFLOW (CFS)48.82.530.51.24.31.530.5LENGTH (FT)850250BOTTOM WIDTH - BW (FT)00N.A.G. S75BNTD#32.17.51.530.53500TD#42.58.91.530.56800SHEAR(LB/FT^2)0.590.230.290.36N.A.G. S75BNN.A.G. S75BNN.A.G. S75BNTEMPORARY SEDIMENT BASIN SCHEDULENAMEDRAINAGEAREA(AC)10 YEARFLOW(CFS)S.A.REQUIRED(SF)S.A.PROVIDED(SF)DIMS. @ BASINBOTTOM(FT)DIMS.@ TOP OFSTORAGE(FT)VOLUMEREQUIRED(CF)VOLUMEPROVIDED(CF)DEPTH(FT)BASIN BOTTOMELEV(FT)TOP OFSTORAGE ELEV(FT)WEIR ELEV(FT)TOP OF BERMELEV(FT)WEIR LENGTH(FT)SKIMMER PIPESIZE (IN)ORIFICEDIAMETER (IN)SB #125.536.617,30417,78753 x 20777 x 23145,90057,5164.0193.0197.0197.5199.03562.7RISER (IN)24BARREL (IN)18CONCRETEBASE (FT)5.5X5.5X1TD#523.349.92.530.5165000.59N.A.G. S75BNTD#67.918.52.030.5127000.41N.A.G. S75BNPC#616.831.93.040.635000.38N.A.G. S75BNFESCUEDISTURBED AREA =29.1 ACROCKFISH ROAD - SR#1403OUTLET PROTECTION #100La=8.0'W=6.0'd=12"STONE Ø= CLASS A RIP RAPOUTLET PROTECTION #200La=18.0'W=9.0'd=18"STONE Ø= CLASS B RIP RAPOUTLET PROTECTION #300La=6.0'W=4.5'd=12"STONE Ø= CLASS A RIP RAPOUTLET PROTECTION #400La=15.0'W=7.5'd=18"STONE Ø= CLASS B RIP RAP INV.=1 9 6. 3' INV.= 1 9 5 . 5 9'CTCT TGRAYSTONE LANEHAYL O F T C O U R T CRAFTSMAN COURT NEWCASTLE COURT2345671581691710111213141819202122232425262728OPENSPACE1293031323310A11A200200DA PC #5TOTAL = 29.41 ACOFF-SITE = 19.90 ACDA PC #4ONSITE = 2.43 ACDA PC #3TOTAL = 20.34 ACOFF-SITE = 5.46 ACDA PC #1TOTAL = 11.60 ACOFF-SITE = 9.11 ACROCKFISH ROAD - SR 1403DA PC #1ONSITE = 2.49 ACDA PC #3ONSITE = 14.88 ACDA PC #5ONSITE = 9.51 ACSWEET WILLIAM WAY - SR 1774 2 0 0 200 205 19819819819 8 1 9 9 199 201 2 0 1 202 2 0 2 203 203 204 204 197 197198199200 2 0 0 200200200195 195195195200 200200200200200200 200200200File: C:\Users\DDS2\Desktop\Drafting and Design\2019\2019-23 Winchester Subdivsion\2020.04.22 - Winchester Subdivision CDs.dwg Print Date: 10/21/2020 STORMWATER MANAGEMENT PLAN CONVEYANCE SWALE DRAINAGE AREASC10Drawn by:Designed by:Reviewed by:Date:Scale:Sheet:Project Number:ofREVISIONS NORTH1"=80'20PROFESSIONAL ENGINEER'S SEAL WINCHESTER SUBDIVISION MTBJRTJRTSEPTEMBER 14, 2020ROCKFISH ROAD HOKE COUNTY, NORTH CAROLINA 143 Charlotte Avenue, Suite 104Sanford, North Carolina 27330(919) 777-6010 phonewww.jthomasengineering.comlicense no. C-338918 SEPT 2020: REVISED PER EC COMMENTSISSUEDFOR CONSTRUCTIONJ Thomas Engineering, Inc.civil engineering &planningJTE #: 20-010DDS#: 2019-238 OCT 2020: REVISED PER DRIVEWAY PERMIT COMMENT MOVED CURB TIE TO 6' FROM TRAVEL LANE21 OCT 2020: REVISED PER NCDOT COMMENTS, NCDEQPWS & NCDEQ STORMWATER PERMIT COMMENTSPERCENT IMPERVIOUS =15.2%NOTES:1.CONTRACTOR ENSURE ABSOLUTELY NO SEDIMENT LAID RUNOFF INTO WETLANDS.2.ALL STORM DRAINAGE SHALL BE INSTALLED PER HOKE COUNTY AND/OR NCDOTSTANDARDS AND SPECIFICATIONS.3.THE PROJECT HAS BEEN DESIGNED TO MEET THE LOW DENSITY PROJECT (24% MAXIMPERVIOUS) STANDARDS PER 15A NCAC 02H.1003.4.DRAINAGE DISSIPATION SWALES HAVE BEEN DESIGNED TO MEET 15A NCAC 02H.1003REQUIREMENTS FOR VEGETATED CONVEYANCES AND CURB OUTLET SYSTEMS.5.THIS PLAN SHEET IS FOR STORMWATER REVIEW ONLY.80080160SCALE: 1" = 80'40IMPERVIOUS CALCULATIONSBUILDINGS (SINGLE FAMILY): 2,500 SF HOMES82,500 SF 1.89 ACSTREETS: 79,390 SF1.82 ACDRIVEWAYS : 33,000 SF0.75 ACSIDEWALKS:8,149SF0.19 ACTOTAL IMPERVIOUS AREA:203,039 SF4.66 ACPERVIOUS AREA:1,134,52226.04 ACTOTAL PROJECT AREA: 1,337,561 SF30.71 ACTOTAL PERCENT IMPERVIOUS: 15.2%PC#1STORMWATERCONVEYANCEPC#3STORMWATERCONVEYANCEPC#4STORMWATERCONVEYANCEPC#5STORMWATERCONVEYANCEEX. DRAINAGE SWALE (TYP) File: C:\Users\DDS2\Desktop\Drafting and Design\2019\2019-23 Winchester Subdivsion\2020.04.22 - Winchester Subdivision CDs.dwg Print Date: 10/21/2020 DETAILSC11NTSDrawn by:Designed by:Reviewed by:Date:Scale:Sheet:Project Number:ofREVISIONS 20PROFESSIONAL ENGINEER'S SEAL WINCHESTER SUBDIVISION MTBJRTJRTSEPTEMBER 14, 2020ROCKFISH ROAD HOKE COUNTY, NORTH CAROLINA 143 Charlotte Avenue, Suite 104Sanford, North Carolina 27330(919) 777-6010 phonewww.jthomasengineering.comlicense no. C-338918 SEPT 2020: REVISED PER EC COMMENTSISSUEDFOR CONSTRUCTIONJ Thomas Engineering, Inc.civil engineering &planningJTE #: 20-010DDS#: 2019-238 OCT 2020: REVISED PER DRIVEWAY PERMIT COMMENT MOVED CURB TIE TO 6' FROM TRAVEL LANE21 OCT 2020: REVISED PER NCDOT COMMENTS, NCDEQPWS & NCDEQ STORMWATER PERMIT COMMENTSNTS TYPICAL ASPHALT PAVEMENTCOMPACTED SUBGADENOTE: THIS DETAIL SHOWS THE MINIMUM PAVEMENT DESIGN THICKNESS. IT IS RECOMMENDED FOR GEOTECHNICAL ENGINEER TO REVIEW SUBSURFACE CONDITIONS AND PROVIDE FINAL PAVEMENT DESIGN BASED ON ACTUALSOIL CONDITIONS AND ANTICIPATED TRAFFIC LOADING.(95% MIN. STANDARD PROCTOR, BELOW TOP 1')(98% MIN. STANDARD PROCTOR, TOP 1')8.0" CABC, NCDOT TYPE I OR IITRANSVERSE EXPANSION JOINTTYPICAL SECTIONPLAN VIEWNOTES:1. TRANSVERSE EXPANSION JOINTS TO BE A MAXIMUM OF 50 FEET.2. ALL CONCRETE TO BE FINISHED WITH CURING COMPOUND.3. A 5 INCH DEPTH IS SPECIFIED AT LOCATIONS OF DRIVEWAY CROSSINGS AND INTHE HANDICAP RAMPS.PROPOSED SIDEWALK(CONCRETE 3000 P.S.I.)0.02'/FTSIDEWALK SURFACEJOINT FILLER1/8" RADIUSPROPOSED SIDEWALK5'-0"4"1/4"1/2"NCDOT APPROVED STOP SIGNNTS5'-0"MAXIMUM CONTRACTION JOINTLOCAL RESIDENTIAL - ALL ROADS(29' B-B, 50' R/W)8.0" CABC, NCDOTTYPE I OR IICOMPACTED SUBGRADE95% STANDARD PROCTOR24" CONCRETE ROLL CURB25' EP - EP STREET WIDTH50' PUBLIC ROW2.0'2% SLOPE2.0" S9.5BASPHALT2% SLOPEFILL SLOPE3:1 MAX .3:1 MAX.CUT SLOPE10.5'STANDARD PAVEMENT DESIGN2" S9.5B8" ABC2% SLOPESHOULDER5.0'SIDEWALKSEE PLANFORLOCATION5.0'SIDEWALKEASEMENT2.0'FILL SLOPE3:1 MAX.3:1 MAX .CUT SLOPE10.5'2% SLOPESHOULDER5.0'SIDEWALKSEE PLANFORLOCATION5.0'SIDEWALKEASEMENT29' BC - BC STREET WIDTH2" ASPHALT SURFACE - TYPE SF9.5B24" CONCRETE ROLL CURBEASEMENT RIGHT-OF-WAY RIGHT-OF-WAY EASEMENTNTS SIDEWALK SHALL BE 6"MIN DEPTH AT DRIVEWAYCROSSINGSEXTEND 8" CABC12" BEYOND BACK OF CURBEXTEND 8" CABC12" BEYOND BACK OF CURBCUL-DE-SAC - ALL ROADS(97.0' B-B, 117' R/W)8.0" CABC, NCDOTTYPE I OR IICOMPACTED SUBGRADE95% STANDARD PROCTOR24" CONCRETE ROLL CURB93' EP - EP STREET WIDTHVARIES 50' - 117.0' PUBLIC ROW2.0'SLOPE VARIES (SEE PLAN)2.0" S9.5BASPHALTSLOPE VARIES (SEE PLAN)FILL SLOPE3:1 MAX .3:1 MAX.CUT SLOPE10.0'STANDARD PAVEMENT DESIGN2" S9.5B8" ABC2% SLOPESHOULDER2.0'FILL SLOPE3:1 MAX.3:1 MAX .CUT SLOPE10.0'2% SLOPESHOULDER97' BC - BC STREET WIDTH24" CONCRETE ROLL CURBRIGHT-OF-WAY RIGHT-OF-WAYNTS EXTEND 8" CABC12" BEYOND BACK OF CURBEXTEND 8" CABC12" BEYOND BACK OF CURBSIDEWALKNTS File: C:\Users\DDS2\Desktop\Drafting and Design\2019\2019-23 Winchester Subdivsion\2020.04.22 - Winchester Subdivision CDs.dwg Print Date: 10/21/2020 DETAILSC12NTSDrawn by:Designed by:Reviewed by:Date:Scale:Sheet:Project Number:ofREVISIONS 20PROFESSIONAL ENGINEER'S SEAL WINCHESTER SUBDIVISION MTBJRTJRTSEPTEMBER 14, 2020ROCKFISH ROAD HOKE COUNTY, NORTH CAROLINA 143 Charlotte Avenue, Suite 104Sanford, North Carolina 27330(919) 777-6010 phonewww.jthomasengineering.comlicense no. C-338918 SEPT 2020: REVISED PER EC COMMENTSISSUEDFOR CONSTRUCTIONJ Thomas Engineering, Inc.civil engineering &planningJTE #: 20-010DDS#: 2019-238 OCT 2020: REVISED PER DRIVEWAY PERMIT COMMENT MOVED CURB TIE TO 6' FROM TRAVEL LANE21 OCT 2020: REVISED PER NCDOT COMMENTS, NCDEQPWS & NCDEQ STORMWATER PERMIT COMMENTS0.281"0.25"16"8"STEEL CASING36"30"24"18"16"12"48"30"24"42"36"30"0.500"0.312"0.25"0.500"0.375"0.312"0.688"0.469"0.375"0.625"0.532"0.469"MIN. WALL THICKNESSCARRIER PIPE SIZEBORE SIZING CHART*MIN. WALL THICKNESSCASING SIZEMIN.ROADWAYSRAILROADSCARBON STEEL CARRIER PIPE BRACESHALL BE PLACED 3' PRIOR TO AND 3'AFTER EACH JOINT OF DUCTILE IRONCARRIER PIPE. (SEE DETAIL BOREUNDER ROADWAYS/RAILROADS SHEET 2OF 2 FOR SPECIFIC REQUIREMENTS)SEAL EACH END OF CASINGWITH SOLID CONCRETE BRICKAND 1:3 MORTAR 12" MINIMUM LENGTH.STEEL CASING SIZED AS INDICATEDON THE BORE SIZING CHART.CARRIER PIPE SHALL BEDUCTILE IRON WITH PROPEREXTERIOR AND INTERIORCOATINGSSOLID CONCRETE BRICKAND 1:3 MORTAR, COMPLETELYFILL VOIDS BETWEEN BRICKWITH MORTAR, CLOSE EACH ENDOF CASING.RUNNERS SHALL BE MIN. 2" WIDE RJDI CARRIER PIPEAANOTE:1.SEE DRAWING M.6 SHEET 2 OF 2FOR ADDITIONAL INFORMATION.2.CARRIER PIPE FOR PRESSUREAPPLICATIONS (WATER MAINSAND FORCE MAINS) SHALL HAVEFACTORY RESTRAINED JOINTS.CARRIER PIPE FOR GRAVITYSEWER SHALL HAVE RESTRAINEDJOINTS AND MAY USERESTRAINING GASKETS SUCH ASFIELD LOC, SURE STOP 350 OROTHER APPROVED GASKETS3.CARRIER PIPE SHALL BE CLASS350 OR 250 FOR WATER, ANDSHALL BE CLASS 50 FOR SEWER.6"12"0.25"0.281"4"10"0.188"0.188"COMPLETELY FILLVOID OUTSIDE OFCASING WITH 1:3GROUT.HALF SECTION ISOMETRIC OF BOREEACH SECTION OFENCASEMENT PIPESHALL BE BUTT-WELDEDTO THE ADJACENTCASING PIPE.NOTES:1.INSTALLATION SHALL BE DRY BORE AND JACKING OF SMOOTH WALLSTEEL PIPE. JETTING OR WET BORING WITH WATER SHALL NOT BEALLOWED.2.SEE BORE SIZING CHART FOR CARRIER PIPE SIZE AND STEEL CASINGSIZE, MINIMUM DIAMETER, AND WALL THICKNESS.3.CASING PIPE SHALL BE IN ACCORDANCE WITH ASTM A-53, GRADE BWITH A MINIMUM YIELD STRENGTH OF 35,000PSI.4.EACH END OF ENCASEMENT TO BE PLUGGED WITH BRICK. ALL VOIDSOUTSIDE THE CASING PIPE SHALL BE COMPLETELY FILLED WITH 1:3PORTLAND CEMENT GROUT AT SUFFICIENT PRESSURE TO INSURE NOSETTLEMENT OF ROADWAY/RAILROAD. METHOD OF GROUTING SHALLBE AS APPROVED BY THE PERMITTING AGENCY.5.IT IS RECOMMENDED THAT THE BORE BE ACCOMPLISHED BEFORE PIPECONSTRUCTION BEGINS.6.THE BORING SHALL BE PERFORMED FROM "UPSTREAM" TO"DOWNSTREAM" DIRECTION MAINTAINING THE CRITICAL DOWNSTREAMINVERT ELEVATION. SHOULD THE BORE NOT BE ON GRADE, A REVISEDPLAN SHALL BE SUBMITTED TO FAYPWC FOR APPROVAL.7.THE BORING OPERATION SHALL BE CONDUCTED IN A MANNER THATTHE FLOW OF TRAFFIC IS NOT IMPEDED OR IN SUCH A MANNER SO ASNOT TO CREATE A HAZARD.8.IF AN OBSTRUCTION IS ENCOUNTERED DURING THE BORINGOPERATION, THE AUGER SHALL BE WITHDRAWN, THE EXCESS CASINGPIPE CUT-OFF, CAPPED AND THE INTERIOR AND EXTERIOR VOIDSSHALL BE COMPLETELY FILLED WITH 1:3 PORTLAND CEMENT GROUTUNDER PRESSURE. NO SEPARATE PAYMENT FOR UNSUCCESSFULBORES.9.CONTRACTOR SHALL FIELD ADJUST AND INSTALL PROPER PIPEBRACES TO ACCOMPLISH GRADE AND INVERTS AS SHOWN ON THEDRAWINGS.10.A MANUAL CONTROL STEERING HEAD OR OTHER GUIDANCE SYSTEM ISRECOMMENDED FOR BORES 30" DIAMETER AND/OR LARGER AND FORBORES EXCEEDING 100' IN LENGTH OR AS SPECIFIED.11.SUBCONTRACTORS SHALL ADHERE TO ALL PERMIT REQUIREMENTSAND SHALL PROVIDE APPROVED INSURANCE CERTIFICATES ASREQUIRED.12.CONTRACTOR SHALL EXECUTE AND PERFORM ALL REQUIREMENTSAND CONDITIONS STIPULATED BY THE PERMITTING AGENCY.13.SEE DRAWING M.6 SHEET 1 OF 2 FOR ADDITIONAL INFORMATION.14.CARRIER PIPE FOR PRESSURE APPLICATIONS (WATER MAINS ANDFORCE MAINS) SHALL HAVE FACTORY RESTRAINED JOINTS. CARRIERPIPE FOR GRAVITY SEWER SHALL HAVE RESTRAINED JOINTS AND MAYUSE RESTRAINING GASKETS SUCH AS FIELD LOK, SURE STOP 350 OROTHER APPROVED GASKETS.*CONTRACTOR MAY SUBSTITUTE A LARGER SIZE CASING PIPE HAVING THEMINIMUM WALL THICKNESS SHOWN FOR SEWER MAINS. ALL ADDITIONALCOSTS SHALL BE INCLUDED IN THE NIT PRICE BID FOR BORING AND JACKING.FASTEN BRACE TO PIPEWITH HEAVY DUTY STUDS,NUTS, AND WASHERS.COMPLETELY FILLVOID OUTSIDE OFCASING WITH GROUTSEE NOTE 4.BAND - 12 GAUGE MIN.,RISER - 8 GAUGE MIN.CARBON STEELSECTION "A-A" CARBON STEEL CARRIER PIPE BRACENTS TYPICAL BORE AND JACK UNDER HIGHWAYS/RAILROADS File: C:\Users\DDS2\Desktop\Drafting and Design\2019\2019-23 Winchester Subdivsion\2020.04.22 - Winchester Subdivision CDs.dwg Print Date: 10/21/2020 DETAILS - NCDOTC13NTSDrawn by:Designed by:Reviewed by:Date:Scale:Sheet:Project Number:ofREVISIONS 20PROFESSIONAL ENGINEER'S SEAL WINCHESTER SUBDIVISION MTBJRTJRTSEPTEMBER 14, 2020ROCKFISH ROAD HOKE COUNTY, NORTH CAROLINA 143 Charlotte Avenue, Suite 104Sanford, North Carolina 27330(919) 777-6010 phonewww.jthomasengineering.comlicense no. C-338918 SEPT 2020: REVISED PER EC COMMENTSISSUEDFOR CONSTRUCTIONJ Thomas Engineering, Inc.civil engineering &planningJTE #: 20-010DDS#: 2019-238 OCT 2020: REVISED PER DRIVEWAY PERMIT COMMENT MOVED CURB TIE TO 6' FROM TRAVEL LANE21 OCT 2020: REVISED PER NCDOT COMMENTS, NCDEQPWS & NCDEQ STORMWATER PERMIT COMMENTS File: C:\Users\DDS2\Desktop\Drafting and Design\2019\2019-23 Winchester Subdivsion\2020.04.22 - Winchester Subdivision CDs.dwg Print Date: 10/21/2020 DETAILS - NCDOTC14NTSDrawn by:Designed by:Reviewed by:Date:Scale:Sheet:Project Number:ofREVISIONS 20PROFESSIONAL ENGINEER'S SEAL WINCHESTER SUBDIVISION MTBJRTJRTSEPTEMBER 14, 2020ROCKFISH ROAD HOKE COUNTY, NORTH CAROLINA 143 Charlotte Avenue, Suite 104Sanford, North Carolina 27330(919) 777-6010 phonewww.jthomasengineering.comlicense no. C-338918 SEPT 2020: REVISED PER EC COMMENTSISSUEDFOR CONSTRUCTIONJ Thomas Engineering, Inc.civil engineering &planningJTE #: 20-010DDS#: 2019-238 OCT 2020: REVISED PER DRIVEWAY PERMIT COMMENT MOVED CURB TIE TO 6' FROM TRAVEL LANE21 OCT 2020: REVISED PER NCDOT COMMENTS, NCDEQPWS & NCDEQ STORMWATER PERMIT COMMENTS2'-0"CURB TRANISITION 2'-0" TO 2'-6"NTSNOTE:THIS DETAIL IS AMODIFIED VERSIONOF NCDOT 852.05 File: C:\Users\DDS2\Desktop\Drafting and Design\2019\2019-23 Winchester Subdivsion\2020.04.22 - Winchester Subdivision CDs.dwg Print Date: 10/21/2020 DETAILS - EROSION CONTROLC15NTSDrawn by:Designed by:Reviewed by:Date:Scale:Sheet:Project Number:ofREVISIONS 20PROFESSIONAL ENGINEER'S SEAL WINCHESTER SUBDIVISION MTBJRTJRTSEPTEMBER 14, 2020ROCKFISH ROAD HOKE COUNTY, NORTH CAROLINA 143 Charlotte Avenue, Suite 104Sanford, North Carolina 27330(919) 777-6010 phonewww.jthomasengineering.comlicense no. C-338918 SEPT 2020: REVISED PER EC COMMENTSISSUEDFOR CONSTRUCTIONJ Thomas Engineering, Inc.civil engineering &planningJTE #: 20-010DDS#: 2019-238 OCT 2020: REVISED PER DRIVEWAY PERMIT COMMENT MOVED CURB TIE TO 6' FROM TRAVEL LANE21 OCT 2020: REVISED PER NCDOT COMMENTS, NCDEQPWS & NCDEQ STORMWATER PERMIT COMMENTSNCG01 GROUND STABILIZATION AND MATERIALS HANDLINGEFFECTIVE: 04/01/19GROUND STABILIZATION AND MATERIALS HANDLING PRACTICES FOR COMPLIANCE WITHTHE NCG01 CONSTRUCTION GENERAL PERMITImplementing the details and specifications on this plan sheet will result in the constructionactivity being considered compliant with the Ground Stabilization and Materials Handlingsections of the NCG01 Construction General Permit (Sections E and F, respectively). Thepermittee shall comply with the Erosion and Sediment Control plan approved by thedelegated authority having jurisdiction. All details and specifications shown on this sheetmay not apply depending on site conditions and the delegated authority having jurisdiction.GROUND STABILIZATION SPECIFICATIONStabilize the ground sufficiently so that rain will not dislodge the soil. Use one of thetechniques in the table below:POLYACRYLAMIDES (PAMS) AND FLOCCULANTS1.Select flocculants that are appropriate for the soils being exposed duringconstruction, selecting from the NC DWR List of Approved PAMS/Flocculants.2.Apply flocculants at or before the inlets to Erosion and Sediment Control Measures.3.Apply flocculants at the concentrations specified in the NC DWR List of ApprovedPAMS/Flocculants and in accordance with the manufacturer's instructions.4.Provide ponding area for containment of treated Stormwater before dischargingoffsite.5.Store flocculants in leak-proof containers that are kept under storm-resistant coveror surrounded by secondary containment structures.HAZARDOUS AND TOXIC WASTE1.Create designated hazardous waste collection areas on-site.2.Place hazardous waste containers under cover or in secondary containment.3.Do not store hazardous chemicals, drums or bagged materials directly on the ground.EQUIPMENT AND VEHICLE MAINTENANCE1.Maintain vehicles and equipment to prevent discharge of fluids.2.Provide drip pans under any stored equipment.3.Identify leaks and repair as soon as feasible, or remove leaking equipment from theproject.4.Collect all spent fluids, store in separate containers and properly dispose ashazardous waste (recycle when possible).5.Remove leaking vehicles and construction equipment from service until the problemhas been corrected.6.Bring used fuels, lubricants, coolants, hydraulic fluids and other petroleum productsto a recycling or disposal center that handles these materials.LITTER, BUILDING MATERIAL AND LAND CLEARING WASTE1.Never bury or burn waste. Place litter and debris in approved waste containers.2.Provide a sufficient number and size of waste containers (e.g dumpster, trashreceptacle) on site to contain construction and domestic wastes.3.Locate waste containers at least 50 feet away from storm drain inlets and surfacewaters unless no other alternatives are reasonably available.4.Locate waste containers on areas that do not receive substantial amounts of runofffrom upland areas and does not drain directly to a storm drain, stream or wetland.5.Cover waste containers at the end of each workday and before storm events orprovide secondary containment. Repair or replace damaged waste containers.6.Anchor all lightweight items in waste containers during times of high winds.7.Empty waste containers as needed to prevent overflow. Clean up immediately ifcontainers overflow.8.Dispose waste off-site at an approved disposal facility.9.On business days, clean up and dispose of waste in designated waste containers.PAINT AND OTHER LIQUID WASTE1.Do not dump paint and other liquid waste into storm drains, streams or wetlands.2.Locate paint washouts at least 50 feet away from storm drain inlets and surfacewaters unless no other alternatives are reasonably available.3.Contain liquid wastes in a controlled area.4.Containment must be labeled, sized and placed appropriately for the needs of site.5.Prevent the discharge of soaps, solvents, detergents and other liquid wastes fromconstruction sites.PORTABLE TOILETS1.Install portable toilets on level ground, at least 50 feet away from storm drains,streams or wetlands unless there is no alternative reasonably available. If 50 footoffset is not attainable, provide relocation of portable toilet behind silt fence or placeon a gravel pad and surround with sand bags.2.Provide staking or anchoring of portable toilets during periods of high winds or in highfoot traffic areas.3.Monitor portable toilets for leaking and properly dispose of any leaked material.Utilize a licensed sanitary waste hauler to remove leaking portable toilets and replacewith properly operating unit.HERBICIDES, PESTICIDES AND RODENTICIDES1.Store and apply herbicides, pesticides and rodenticides in accordance with labelrestrictions.2.Store herbicides, pesticides and rodenticides in their original containers with thelabel, which lists directions for use, ingredients and first aid steps in case ofaccidental poisoning.3.Do not store herbicides, pesticides and rodenticides in areas where flooding ispossible or where they may spill or leak into wells, stormwater drains, ground wateror surface water. If a spill occurs, clean area immediately.4.Do not stockpile these materials onsite.CONCRETE WASHOUTS1.Do not discharge concrete or cement slurry from the site.2.Dispose of, or recycle settled, hardened concrete residue in accordance with localand state solid waste regulations and at an approved facility.3.Manage washout from mortar mixers in accordance with the above item and inaddition place the mixer and associated materials on impervious barrier and withinlot perimeter silt fence.4.Install temporary concrete washouts per local requirements, where applicable. If analternate method or product is to be used, contact your approval authority forreview and approval. If local standard details are not available, use one of the twotypes of temporary concrete washouts provided on this detail.5.Do not use concrete washouts for dewatering or storing defective curb or sidewalksections. Stormwater accumulated within the washout may not be pumped into ordischarged to the storm drain system or receiving surface waters. Liquid waste mustbe pumped out and removed from project.6.Locate washouts at least 50 feet from storm drain inlets and surface waters unless itcan be shown that no other alternatives are reasonably available. At a minimum,install protection of storm drain inlet(s) closest to the washout which could receivespills or overflow.7.Locate washouts in an easily accessible area, on level ground and install a stoneentrance pad in front of the washout. Additional controls may be required by theapproving authority.8.Install at least one sign directing concrete trucks to the washout within the projectlimits. Post signage on the washout itself to identify this location.9.Remove leavings from the washout when at approximately 75% capacity to limitoverflow events. Replace the tarp, sand bags or other temporary structuralcomponents when no longer functional. When utilizing alternative or proprietaryproducts, follow manufacturer's instructions.10.At the completion of the concrete work, remove remaining leavings and dispose ofin an approved disposal facility. Fill pit, if applicable, and stabilize any disturbancecaused by removal of washout.EARTHEN STOCKPILE MANAGEMENT1.Show stockpile locations on plans. Locate earthen-material stockpile areas at least50 feet away from storm drain inlets, sediment basins, perimeter sediment controlsand surface waters unless it can be shown no other alternatives are reasonablyavailable.2.Protect stockpile with silt fence installed along toe of slope with a minimum offset offive feet from the toe of stockpile.3.Provide stable stone access point when feasible.4.Stabilize stockpile within the timeframes provided on this sheet and in accordancewith the approved plan and any additional requirements. Soil stabilization is definedas vegetative, physical or chemical coverage techniques that will restrain acceleratederosion on disturbed soils for temporary or permanent control needs.AABELOW GRADE WASHOUT STRUCTURE1:1SIDE SLOPE(TYP.)10 MILPLASTICLINING3'-0" MIN. & X' MAX.SECTION A-ANOT TO SCALEABOVE GRADE WASHOUT STRUCTURENOT TO SCALEPLANSECTION B-BHIGHCOHESIVE &LOW FILTRATIONSOIL BERM8"6"2'HIGHCOHESIVE &LOW FILTRATIONSOIL BERM1:1 SIDE SLOPE(TYP.)10 MILPLASTIC LININGBB3'-0" MIN. & X' MAX.ASANDBAGS (TYP.)OR STAPLESSANDBAGS (TYP.)OR STAPLESSANDBAGS (TYP.)OR STAPLESSANDBAGS (TYP.)OR STAPLESNOTES:1. ACTUAL LOCATION DETERMINED IN FIELD2. THE CONCRETE WASHOUT STRUCTURES SHALL BEMAINTAINED WHEN THE LIQUID AND/OR SOLID REACHES75% OF THE STRUCTURES CAPACITY.3.CONCRETE WASHOUT STRUCTURE NEEDS TO BECLEARY MARKED WITH SIGNAGE NOTING DEVICE.NOTES:1. ACTUAL LOCATION DETERMINED IN FIELD2. THE CONCRETE WASHOUT STRUCTURESSHALL BE MAINTAINED WHEN THE LIQUIDAND/OR SOLID REACHES 75% OF THESTRUCTURES CAPACITY TO PROVIDEADEQUATE HOLDING CAPACITY WITH AMINIMUM 12 INCHES OF FREEBOARD.3.CONCRETE WASHOUT STRUCTURE NEEDSTO BE CLEARY MARKED WITH SIGNAGENOTING DEVICE.ONSITE CONCRETE WASHOUTSTRUCTURE WITH LINERCONCRETEWASHOUTCONCRETEWASHOUTPLANCLEARLY MARKED SIGNAGENOTING DEVICE (18"X24" MIN.)CLEARLY MARKED SIGNAGENOTING DEVICE (18"X24" MIN.)SILT FENCE10' MIN 10'MINSECTION E: GROUND STABILIZATIONRequired Ground Stabilization TimeframesNote: After the permanent cessation of construction activities, any areas with temporaryground stabilization shall be converted to permanent ground stabilization as soon aspracticable but in no case longer than 90 calendar days after the last land disturbingactivity. Temporary ground stabilization shall be maintained in a manner to render thesurface stable against accelerated erosion until permanent ground stabilization is achieved.Site Area DescriptionTimeframe variations-7 days for perimeter dikes, swales,ditches, perimeter slopes and HQW Zones-10 days for Falls Lake Watershed unlessthere is zero slopeStabilize within thismany calendardays after ceasingland disturbance77714NoneNone(a)Perimeter dikes,swales, ditches, andperimeter slopes(b)High Quality Water(HQW) Zones(c)Slopes steeper than3:1If slopes are 10' or less in length and arenot steeper than 2:1, 14 days areallowed(d)Slopes 3:1 to 4:1(e)Areas with slopesflatter than 4:114-7 days for slopes greater than 50' inlength and with slopes steeper than 4:1-7 days for perimeter dikes, swales,ditches, perimeter slopes and HQWZones-10 days for Falls Lake WatershedNCG01 SELF-INSPECTION, RECORDKEEPING AND REPORTINGEFFECTIVE: 04/01/19PART IIISELF-INSPECTION, RECORDKEEPING AND REPORTINGSECTION A: SELF-INSPECTIONSelf-inspections are required during normal business hours in accordance with the tablebelow. When adverse weather or site conditions would cause the safety of the inspectionpersonnel to be in jeopardy, the inspection may be delayed until the next business day onwhich it is safe to perform the inspection. In addition, when a storm event of equal to orgreater than 1.0 inch occurs outside of normal business hours, the self-inspection shall beperformed upon the commencement of the next business day. Any time when inspectionswere delayed shall be noted in the Inspection Record.NOTE: The rain inspection resets the required 7 calendar day inspection requirement.PART IIISELF-INSPECTION, RECORDKEEPING AND REPORTINGSECTION B: RECORDKEEPING1.E&SC Plan DocumentationThe approved E&SC plan as well as any approved deviation shall be kept on the site. Theapproved E&SC plan must be kept up-to-date throughout the coverage under this permit.The following items pertaining to the E&SC plan shall be documented in the mannerdescribed:2. Additional Documentation In addition to the E&SC Plan documents above, the following items shall be kept on thesite and available for agency inspectors at all times during normal business hours, unless the Division provides a site-specific exemption based on unique site conditions that make this requirement not practical:(a)This general permit as well as the certificate of coverage, after it is received.(b)Records of inspections made during the previous 30 days. The permittee shall recordthe required observations on the Inspection Record Form provided by the Division ora similar inspection form that includes all the required elements. Use ofelectronically-available records in lieu of the required paper copies will be allowed ifshown to provide equal access and utility as the hard-copy records.(c)All data used to complete the Notice of Intent and older inspection records shall bemaintained for a period of three years after project completion and made availableupon request. [40 CFR 122.41]PART IIISELF-INSPECTION, RECORDKEEPING AND REPORTINGSECTION C: REPORTING1.Occurrences that must be reportedPermittees shall report the following occurrences:(a)Visible sediment deposition in a stream or wetland.(b)Oil spills if:·They are 25 gallons or more,·They are less than 25 gallons but cannot be cleaned up within 24 hours,·They cause sheen on surface waters (regardless of volume), or·They are within 100 feet of surface waters (regardless of volume).(a)Releases of hazardous substances in excess of reportable quantities under Section 311of the Clean Water Act (Ref: 40 CFR 110.3 and 40 CFR 117.3) or Section 102 of CERCLA(Ref: 40 CFR 302.4) or G.S. 143-215.85.(b)Anticipated bypasses and unanticipated bypasses.(c)Noncompliance with the conditions of this permit that may endanger health or theenvironment.2.Reporting Timeframes and Other RequirementsAfter a permittee becomes aware of an occurrence that must be reported, he shall contactthe appropriate Division regional office within the timeframes and in accordance with theother requirements listed below. Occurrences outside normal business hours may also bereported to the Division's Emergency Response personnel at (800) 662-7956, (800)858-0368 or (919) 733-3300. File: C:\Users\DDS2\Desktop\Drafting and Design\2019\2019-23 Winchester Subdivsion\2020.04.22 - Winchester Subdivision CDs.dwg Print Date: 10/21/2020 DETAILS - EROSION CONTROLC16NTSDrawn by:Designed by:Reviewed by:Date:Scale:Sheet:Project Number:ofREVISIONS 20PROFESSIONAL ENGINEER'S SEAL WINCHESTER SUBDIVISION MTBJRTJRTSEPTEMBER 14, 2020ROCKFISH ROAD HOKE COUNTY, NORTH CAROLINA 143 Charlotte Avenue, Suite 104Sanford, North Carolina 27330(919) 777-6010 phonewww.jthomasengineering.comlicense no. C-338918 SEPT 2020: REVISED PER EC COMMENTSISSUEDFOR CONSTRUCTIONJ Thomas Engineering, Inc.civil engineering &planningJTE #: 20-010DDS#: 2019-238 OCT 2020: REVISED PER DRIVEWAY PERMIT COMMENT MOVED CURB TIE TO 6' FROM TRAVEL LANE21 OCT 2020: REVISED PER NCDOT COMMENTS, NCDEQPWS & NCDEQ STORMWATER PERMIT COMMENTSTEMPORARY SEEDINGPROVIDE TEMPORARY SEEDING TO ALL DENUDED AREAS THAT WILL NOT BE BROUGHT TO FINAL GRADE WITHIN THE FOLLOWING SCHEDULE:PERMANENT DITCHES --> IMMEDIATELY (ROCK LINED)SLOPES 4:1 OR STEEPER --> 7 DAYSALL OTHER AREAS --> 14 DAYSIF SOILS BECOME COMPACTED DURING GRADING, LOOSEN THEM TO A DEPTH OF 6-8 INCHES.SEEDBED PREPARATION:LIME: APPLY LIME ACCORDING TO SOIL TEST RECOMMENDATIONS. IF THE SOIL PH IS NOT KNOWN, APPLY AT A RATE OF 1 TO 1 12 TONS PERACRE ON COARSE-TEXTURED SOILS AND 2-3 TONS PER ACRE OF FINE-TEXTURED SOILS. APPLY LIME UNIFORMLY AND INCORPORATE INTOTHE TOP 4-6 INCHES OF SOIL. SOILS WITH PH HIGHER THAN 6 DO NOT NEED LIME.FERTILIZER: FERTILIZE ACCORDING TO SOIL TEST RECOMMENDATIONS. WHERE SOIL TESTS ARE NOT AVAILABLE, APPLY A 10-10-10 GRADEFERTILIZER AT 700-1,000 LB/ACRE. INCORPORATE FERTILIZER INTO THE TOP 4-6 INCHES OF SOIL. IF A HYDRAULIC SEEDER IS USED, DO NOTMIX SEED AND FERTILIZER MORE THAN 30 MINUTES BEFORE APPLICATION.SURFACE ROUGHENING: IF AREAS TO BE SEEDED BECOME HARDENED, SEALED, OR CRUSTED, LOOSEN IT JUST PRIOR TO SEEDING BYDISKING, RAKING, HARROWING OR OTHER SUITABLE METHODS. GROOVE OR FURROW SLOPES STEEPER THAN 3:1 ON THE CONTOURBEFORE SEEDING.PLANT SELECTION:SELECT THE APPROPRIATE SPECIES BASED ON THE PLANTING SEASON.SEEDING:APPLY SEED WITH A BROADCAST SEEDER, DRILL, CULTIPACKER SEEDER, OR HYDROSEEDER. USE SEEDING RATES GIVEN IN TABLES.BROADCAST SEEDING AND HYDROSEEDING IS ACCEPTABLE ON STEEP SLOPES WHERE EQUIPMENT CANNOT BE DRIVEN. HANDBROADCASTING IS NOT RECOMMENDED.SMALL GRAINS SHOULD BE PLANTED NO MORE THAN ONE INCH DEEP AND GRASSES AND LEGUMES ON MORE THAN 12 INCH. BROADCASTSEED MUST BE COVERED BY RAKING OR CHAIN DRAGGING, AND THEN LIGHTLY FIRMED WITH A ROLLER OR CULTIPACKER. HYDROSEEDEDMIXTURES SHOULD NOT INCLUDE A WOOD FIBER MULCH.MULCHING:MULCHING IS REQUIRED FOR ALL TEMPORARY SEEDING AT A MIN RATE OF 2 TONS/ACRE WITH ASPHALT TACK.MAINTENANCE:CONTRACTOR TO MONITOR GRASS ESTABLISHMENT. PROMPTLY RESEEED AREAS WHERE A HEALTHY, DENSE GROWTH DOES NOTESTABLISH. CONTRACTOR MAY NEED TO PROVIDE NETTING OR TEMPORARY LINERS TO AREAS WHERE GRASS CANNOT BE ESTABLISHEDDUE TO EROSION.PERMANENT SEEDINGSEE SEEDING SCHEDULE FOR SEED TYPE AND RATE.PROVIDE PERMANENT SEEDING TO ALL DENUDED AREAS THAT WILL NOT BE COVERED BY PAVING, BUILDINGS, OR OTHER LANDSCAPING. AREASRECEIVING PERMANENT VEGETATION MUST BE STABILIZED WITHIN THE FOLLOWING TIMEFRAMES AFTER FINAL GRADE IS REACHED, UNLESSTEMPORARY STABILIZATION IS APPLIED.PERMANENT DITCHES --> IMMEDIATELY (ROCK LINED)SLOPES 4:1 OR STEEPER --> 7 DAYSALL OTHER AREAS --> 14 DAYSCOMPLETE GRADING BEFORE PREPARING SEEDBEDS. IF SOILS BECOME COMPACTED DURING GRADING, LOOSEN THEM TO A DEPTH OF 6-8INCHES.SEEDBED REQUIREMENTS:THE SOIL SHOULD MEET THE FOLLOWING MINIMUM CRITERIA FOR VEGETATION ESTABLISHMENT:·ENOUGH FINE-GRAINED (SILT AND CLAY) MATERIAL TO MAINTAIN ADEQUATE MOISTURE AND NUTRIENT SUPPLY (AVAILABLE WATERCAPACITY OF AT LEAST 0.05 INCHES OF WATER TO 1 INCH OF SOIL·SUFFICIENT PORE SPACE TO PERMIT ROOT PENETRATION.·SUFFICIENT DEPTH OF SOIL TO PROVIDE AN ADEQUATE ROOT ZONE. THE DEPTH OF ROCK OR IMPERMEABLE LAYERS SUCH ASHARDPANS SHOULD BE 12 INCHES OR MORE, EXCEPT ON SLOPES STEEPER THAN 2:1 WHERE THE ADDITION OF SOIL IS NOT FEASIBLE.·A FAVORABLE PH RANGE FOR PLANT GROWTH, USUALLY 6.0-6.5.·NO LARGE ROOTS, BRANCHES, STONES, LARGE CLODS OF EARTH, AND TRASH. CLODS AND STONES MAY BE LEFT ON SLOPESSTEEPER THAN 3:1 IF THEY ARE TO BE HYDROSEEDED.IF THE ABOVE CRITERIA CANNOT BE MET, SPECIAL SOIL CONDITIONERS OR TOPSOIL MAY BE APPLIED.SEEDBED PREPARATION:LIME: APPLY LIME ACCORDING TO SOIL TEST RECOMMENDATIONS. IF THE SOIL PH IS NOT KNOWN, FOLLOW RATES ON THE SEEDING SPECTABLE.FERTILIZER: FERTILIZE ACCORDING TO SOIL TEST RECOMMENDATIONS. WHERE SOIL TESTS ARE NOT AVAILABLE, FOLLOW RATES ON THESEEDING SPEC TABLE.SURFACE ROUGHENING: IF AREAS TO BE SEEDED BECOME HARDENED, SEALED, OR CRUSTED, LOOSEN IT JUST PRIOR TO SEEDING BYDISKING, RAKING, HARROWING OR OTHER SUITABLE METHODS. GROOVE OR FURROW SLOPES STEEPER THAN 3:1 ON THE CONTOURBEFORE SEEDING.PLANT SELECTION:SELECT THE APPROPRIATE SPECIES BASED ON THE PLANTING SEASON, SOIL TYPE, SLOPES, AND LAND USES. SEE SEEDING SPEC TABLESIN PLANS FOR RECOMMENDED PERMANENT SEEDING MIXTURE.SEEDING:USE CERTIFIED SEED (INSPECTED BY THE NORTH CAROLINA CROP IMPROVEMENT ASSOCIATION).APPLY SEED WITH A BROADCAST SEEDER, DRILL, CULTIPACKER SEEDER, OR HYDROSEEDER ON A FIRM, FRIABLE SEEDBED. USE SEEDINGRATES GIVEN IN TABLES.WHEN USING A DRILL OR CULTIPACKER SEEDER, SMALL GRAINS SHOULD BE PLANTED NO MORE THAN ONE INCH DEEP AND GRASSES ANDLEGUMES ON MORE THAN 12 INCH.WHEN BROADCAST SEEDING, SUBDIVIDE AREA INTO WORKABLE SECTIONS AND DETERMINE THE AMOUNT OF SEED NEEDED FOR EACHSECTION. APPLY ONE-HALF THE SEED WHILE MOVING BACK AND FORTH ACROSS THE AREA AND APPLY THE REMAINING SEED IN THE SAMEMANNER BUT AT RIGHT ANGLES TO THE FIRST PASS. COVER SEED BY RAKING OR CHAIN DRAGGING, AND THEN LIGHTLY FIRM WITH AROLLER OR CULTIPACKER.MULCH AREAS IMMEDIATELY AFTER SEEDING IN ACCORDANCE WITH RATES GIVEN IN TABLES. ANCHOR MULCH WITH NETTING OR LIQUIDASPHALT AT A RATE OF 0.10 GALLON PER SQUARE YARD (10 GAL / 1000 SQ FT).HYDROSEEDING:SURFACE ROUGHENING IS REQUIRED. FINE SEEDBED PREPARATION IS NOT NECESSARY.RATE OF WOOD FIBER APPLICATION SHOULD BE AT LEAST 4,000-6,000 LB/ACRE.APPLY LEGUME INOCULANTS AT FOUR TIMES THE RECOMMENDED RATE WHEN ADDING INOCULANT TO HYDROSEEDER SLURRY.APPLY LIME IN DRY FORM.APPLICATIONSTEP 1 -1/3 MULCH RATE, ALL SEEDING AND ALL INOCULANT SPREAD IN ONE DIRECTIONSTEP 2 - 2/3 MULCH RATE APPLIED IN OPPOSING DIRECTIONMAINTENANCE:IF STAND IS INADEQUATE, RE-EVALUATE PLANT CHOICE AND QUANTITIES OF LIME AND FERTILIZER. REESTABLISH THE STAND AFTERSEEDBED PREPARATION OR OVER-SEED THE STAND. CONSIDER SEEDING TEMPORARY, ANNUAL SPECIES IF THE TIME OF YEAR IS NOTAPPROPRIATE FOR PERMANENT SEEDING.MAINTENANCE PLANTHE OPERATOR IS RESPONSIBLE FOR MAINTAINING EROSION CONTROL DEVICES THROUGHOUT THE PROJECT DURATION.ALL EROSION AND SEDIMENT CONTROL DEVICES SHALL BE CHECKED FOR STABILITY AND OPERATION FOLLOWING EVERY RUNOFF-PRODUCINGRAINFALL BUT IN NO CASE LESS THAN ONCE EVERY WEEK. ANY NEEDED REPAIRS SHALL BE MADE IMMEDIATELY TO MAINTAIN ALL DEVICES ASDESIGNED.SKIMMER BASINS:1.BASINS ARE TO BE CLEANED OF SEDIMENT WHEN ITS STORAGE CAPACITY IS REDUCED BY 50%. PLACE SEDIMENT REMOVED FROM THEBASIN IN A STOCKPILE AREA AS SHOWN ON THE PLAN OR AN AREA THAT HAS ADEQUATE EROSION CONTROL MEASURES.2.CHECK BERM STRUCTURE, SPILLWAYS, AND SKIMMER PIPE EVERY WEEK FOR EROSION AND PIPING.3.MAINTAIN BAFFLES AS DIRECTED BELOW.4.ANY RIP RAP DISPLACED FROM SPILLWAY MUST BE REPLACED IMMEDIATELY.5.AFTER ALL AREAS HAVE BEEN PERMANENTLY STABILIZED, REMOVE BASIN (PHASE 2 OF CONSTRUCTION SEQUENCE) AND ALL UNSTABLESEDIMENT. GRADE ACCORDING TO GRADING PLAN OR BLEND IN WITH ADJACENT GRADES - ADDITIONAL COMPACTION EFFORTS MAY BEREQUIRED IF STRUCTURE IS PROPOSED FOR THAT AREA. STABILIZE AREA.BAFFLES:1.MAINTAIN ACCESS TO BAFFLES. SHOULD THE FABRIC COLLAPSE, DECOMPOSE, TEAR, OR BECOME INEFFECTIVE, REPLACE IT PROMPTLY.2.REMOVE BUILDUP SEDIMENT WHEN IT REACHES ONE-HALF FULL. TAKE CARE NOT TO DISTURB BAFFLES DURING CLEANOUT.SILT FENCE:1.SEDIMENT SHALL BE REMOVED FROM BEHIND THE SEDIMENT FENCE WHEN IT BECOMES ABOUT 0.5 FT DEEP AT THE FENCE. THE FENCESHALL BE REPAIRED AS REQUIRED TO MAINTAIN A SUFFICIENT BARRIER.2.SHOULD THE FABRIC OF A SEDIMENT FENCE COLLAPSE, DECOMPOSE, TEAR, OR BECOME INEFFECTIVE, REPLACE IT PROMPTLY.3.AFTER ALL AREAS HAVE BEEN PERMANENTLY STABILIZED, REMOVE ALL FENCING MATERIALS AND UNSTABLE SEDIMENT. GRADE AREATO GRADING PLAN OR BLEND WITH ADJACENT GRADES. STABILIZE AREA.TEMPORARY DIVERSIONS:1.IMMEDIATELY REMOVE EXCESS SEDIMENT FROM FLOW AREA AND REPAIR DIVERSION RIDGE.2.CAREFULLY CHECK OUTLETS AND MAKE TIMELY REPAIRS AS NEEDED.3.AFTER ALL AREAS HAVE BEEN STABILIZED REMOVE THE RIDGE AND THE CHANNEL AND GRADE ACCORDING TO GRADING PLAN ORBLEND WITH ADJACENT GRADES. STABILIZE AREA.RIP RAP LINED DITCHES/CHANNELS/OUTLETS:1.PAY CLOSE ATTENTION TO INLET AND OUTLET SECTIONS WHERE CONCENTRATED FLOW ENTERS.2.INSPECT FOR INDICATIONS OF PIPING, SCOUR HOLES, OR BANK FAILURES. MAKE REPAIRS IMMEDIATELY.3.MAINTAIN VEGETATION ADJACENT TO THE ROCK LINING IN A HEALTHY, VIGOROUS CONDITION TO PROTECT THE AREA FROM EROSIONAND SCOUR.GRASS LINED DITCHES/CHANNELS/SWALES:1.DURING GRASS ESTABLISHMENT PERIOD, INSPECT AFTER EVERY RAINFALL.2.AFTER GRASS HAS ESTABLISHED, INSPECT PERIODICALLY AND AFTER HEAVY RAINFALL. IMMEDIATELY MAKE REPAIRS.3.PAY CLOSE ATTENTION TO INLET AND OUTLET SECTIONS WHERE CONCENTRATED FLOW ENTERS.4.GRASS SHOULD BE MAINTAINED IN A HEALTHY VIGOROUS CONDITION AT ALL TIMES, SINCE IT IS THE PRIMARY EROSION PROTECTION.TEMPORARY SEEDING SCHEDULEWINTER & EARLY SPRINGTEMPORARY SEEDING SCHEDULESUMMERTEMPORARY SEEDING SCHEDULEFALLPERMANENT SEEDING SCHEDULENTS STABILIZATION TIME TABLES File: C:\Users\DDS2\Desktop\Drafting and Design\2019\2019-23 Winchester Subdivsion\2020.04.22 - Winchester Subdivision CDs.dwg Print Date: 10/21/2020 DETAILS - EROSION CONTROLC17NTSDrawn by:Designed by:Reviewed by:Date:Scale:Sheet:Project Number:ofREVISIONS 20PROFESSIONAL ENGINEER'S SEAL WINCHESTER SUBDIVISION MTBJRTJRTSEPTEMBER 14, 2020ROCKFISH ROAD HOKE COUNTY, NORTH CAROLINA 143 Charlotte Avenue, Suite 104Sanford, North Carolina 27330(919) 777-6010 phonewww.jthomasengineering.comlicense no. C-338918 SEPT 2020: REVISED PER EC COMMENTSISSUEDFOR CONSTRUCTIONJ Thomas Engineering, Inc.civil engineering &planningJTE #: 20-010DDS#: 2019-238 OCT 2020: REVISED PER DRIVEWAY PERMIT COMMENT MOVED CURB TIE TO 6' FROM TRAVEL LANE21 OCT 2020: REVISED PER NCDOT COMMENTS, NCDEQPWS & NCDEQ STORMWATER PERMIT COMMENTSNTS SILT FENCE & SILT FENCE OUTLETSILT FENCE GEOTEXTILE FABRICWOVEN WIRE FABRICVARIABLE AS DIRECTED BY THE ENGINEERSTEEL POST32" MIN. WIDTH-END OF SILT FENCE NEEDS TO BE TURNED UPHILL.LINE WIRESMIN. 10 GA. DOES NOT EXCEED 1/4 ACRE AND NEVER IN-USE SILT FENCE ONLY WHEN DRAINAGE AREA AREAS OF CONCENTRATED FLOWNOTE:3'-0"26"FRONT VIEWWIRE FROM TOPINSTALLED TO SECONDSILT FENCE FABRIC8' MAX. FOR ANCHOR WHEN SILTGRADE FENCE IS PROTECTING CATCH BASIN.FILL SLOPE No. 57 WASHED STONE. FENCE FAILURES, USE* FOR REPAIR OF SILTGRADEWIRESINTERMEDIATEMIN. 12-1/2 GA.DIRECTED BY ENGINEER *ANCHOR SKIRT ASSIDE VIEW2'-0"OVER SKIRT *8" MIN. COVER X 4" MIN. FOWARD ALONG TRENCHNTSLABL = THE DISTANCE SUCH THAT POINTSA AND B ARE OF EQUAL ELEVATIONFILTER FABRICCLASS "B" RIP RAP9"MINAAMIN24" MAXAT CENTER2:1 SLOPESECTION A-AFILTER FABRIC1.5'12" NCDOT #5 or#57 WASHEDSTONE1.5'CHECK DAMNTS 3' FILTER FABRICON GROUNDSTEEL FENCE POSTWIRE FENCEHARDWARE CLOTHFILTER OF 1" DIAMETERWASHED STONEBURY 8" OF UPPER EDGE OFFILTER FABRIC IN TRENCHTOP OF SILT FENCEMUST BE AT LEAST 1'ABOVE THE TOP OFTHE WASHED STONESILT FENCEFRONT VIEWSECTION VIEWSTEEL FENCE POSTSET MAX 2' APARTMIN. 18" INTO SOLIDGROUNDBURY WIRE FENCE,FILTER FABRIC,AND HARDWARECLOTH IN TRENCH4' MIN.MAXIMUM24" MIN.12DSLOPESCOMPACTED SOILS1ZZ1NATURAL GROUNDNTS GRASS LINED TEMPORARY/PERMANENT DIVERSIONDITCHGRASS LINEDSEE PLANSTEEL POST (TYP.)INLET OPENINGINLET BOXWIRE MESH12' MIN.WASHED STONENTS INLET PROTECTIONNOTES:1. REMOVE SEDIMENT WHEN HALF OF STONE OUTLET IS COVERED.2. REPLACE STONE AS NEEDED TO ENSURE DEWATERING.NTS OUTLET PROTECTION(OPTIONAL) EXCAVATED SEDIMENT PIT1.5FT MIN DEPTH X CHANNEL TOP WIDTH2:1 MAX SIDE SLOPESFILTER OF 1" DIAMETERWASHED STONEFILTER FABRICBW File: C:\Users\DDS2\Desktop\Drafting and Design\2019\2019-23 Winchester Subdivsion\2020.04.22 - Winchester Subdivision CDs.dwg Print Date: 10/21/2020 DETAILS - EROSION CONTROLC18NTSDrawn by:Designed by:Reviewed by:Date:Scale:Sheet:Project Number:ofREVISIONS 20PROFESSIONAL ENGINEER'S SEAL WINCHESTER SUBDIVISION MTBJRTJRTSEPTEMBER 14, 2020ROCKFISH ROAD HOKE COUNTY, NORTH CAROLINA 143 Charlotte Avenue, Suite 104Sanford, North Carolina 27330(919) 777-6010 phonewww.jthomasengineering.comlicense no. C-338918 SEPT 2020: REVISED PER EC COMMENTSISSUEDFOR CONSTRUCTIONJ Thomas Engineering, Inc.civil engineering &planningJTE #: 20-010DDS#: 2019-238 OCT 2020: REVISED PER DRIVEWAY PERMIT COMMENT MOVED CURB TIE TO 6' FROM TRAVEL LANE21 OCT 2020: REVISED PER NCDOT COMMENTS, NCDEQPWS & NCDEQ STORMWATER PERMIT COMMENTSFRONT VIEWEND VIEWTOP VIEW"C" ENCLOSUREWATER ENTRY UNITARM ASSEMBLYSCHEDULE 40 PVC PIPEPVC VENT PIPEORIFICE PLATEPVC TEESCHEDULE 40 PVC PIPEFLEXIBLE HOSEUNDERSIDE1/2" HOLES IN PVC PIPEPVC ELBOWPVC TEEPVC END CAPPVC END CAPNTS SKIMMER DEWATERING DEVICE(SEE PLAN FOR DIA.)(SEE PLAN FOR DIA.)(SEE PLAN FOR DIA.)NTS TEMPORARY SKIMMER BASIN BAFFLESTOP OF BAFFLE SHOULD BE 6"HIGHER THAN THE BOTTOM OFTHE SPILLWAYDIMENSIONED ANDBAFFLE INSTALLATION OF WIRE HOG WIRE ATTACHED TO POSTS WITH LENGTHS4' MAX.BETWEENPOSTSNOTED ON PLANSPERSPECTIVE VIEWBOTTOM OF BAFFLE IN6" X 6" TRENCH ANDFILLED WITH SOIL ANDCOMPACTED5'EARTH BERMNOTES:SEDIMENT PITFLOW1.NO SILT FENCE ALLOWED. POROUS COIR FIBER BAFFLE REQUIRED.2.DRIVE STEEL FENCE POST AT LEAST 18" INTO SOLID GROUND3.WOOD POSTS ARE NOT ACCEPTABLE4.BAFFLES SPACED A MAXIMUM OF 8' IN FRONTTWO-THIRDS OF SEDIMENT TRAP (CLOSEST TO RIP-RAP WEIR).NTS TEMPORARY SKIMMER BASINW/ IMPERMEABLE LINERATTACH COIR FIBER BAFFLETO HOG WIRE USING WIREW/ IMPERMEABLE LINERROPE FOR MAINTENANCE File: C:\Users\DDS2\Desktop\Drafting and Design\2019\2019-23 Winchester Subdivsion\2020.04.22 - Winchester Subdivision CDs.dwg Print Date: 10/21/2020 DETAILS - EROSION CONTROLC19NTSDrawn by:Designed by:Reviewed by:Date:Scale:Sheet:Project Number:ofREVISIONS 20PROFESSIONAL ENGINEER'S SEAL WINCHESTER SUBDIVISION MTBJRTJRTSEPTEMBER 14, 2020ROCKFISH ROAD HOKE COUNTY, NORTH CAROLINA 143 Charlotte Avenue, Suite 104Sanford, North Carolina 27330(919) 777-6010 phonewww.jthomasengineering.comlicense no. C-338918 SEPT 2020: REVISED PER EC COMMENTSISSUEDFOR CONSTRUCTIONJ Thomas Engineering, Inc.civil engineering &planningJTE #: 20-010DDS#: 2019-238 OCT 2020: REVISED PER DRIVEWAY PERMIT COMMENT MOVED CURB TIE TO 6' FROM TRAVEL LANE21 OCT 2020: REVISED PER NCDOT COMMENTS, NCDEQPWS & NCDEQ STORMWATER PERMIT COMMENTSFRONT VIEWEND VIEWTOP VIEW"C" ENCLOSUREWATER ENTRY UNITARM ASSEMBLYSCHEDULE 40 PVC PIPEPVC VENT PIPEORIFICE PLATEPVC TEESCHEDULE 40 PVC PIPEFLEXIBLE HOSEUNDERSIDE1/2" HOLES IN PVC PIPEPVC ELBOWPVC TEEPVC END CAPPVC END CAPNTS SKIMMER DEWATERING DEVICE(SEE PLAN FOR DIA.)(SEE PLAN FOR DIA.)(SEE PLAN FOR DIA.)NTS TEMPORARY BASIN BAFFLESTOP OF BAFFLE SHOULD BE 6"HIGHER THAN THE BOTTOM OFTHE SPILLWAYDIMENSIONED ANDBAFFLE INSTALLATION OF WIRE HOG WIRE ATTACHED TO POSTS WITH LENGTHS4' MAX.BETWEENPOSTSNOTED ON PLANSPERSPECTIVE VIEWBOTTOM OF BAFFLE IN6" X 6" TRENCH ANDFILLED WITH SOIL ANDCOMPACTED5'EARTH BERMNOTES:SEDIMENT PITFLOW1.NO SILT FENCE ALLOWED. POROUS COIR FIBER BAFFLE REQUIRED.2.DRIVE STEEL FENCE POST AT LEAST 18" INTO SOLID GROUND3.WOOD POSTS ARE NOT ACCEPTABLE4.BAFFLES SPACED A MAXIMUM OF 8' IN FRONTTWO-THIRDS OF SEDIMENT TRAP (CLOSEST TO RIP-RAP WEIR).W/ STONE LININGATTACH COIR FIBER BAFFLETO HOG WIRE USING WIRENTS TYPICAL EXCAVATED EARTH SPILLWAY 14CROSS SECTION AT CONTROL SECTIONMIN. 2%APPROACHCHANNEL20'LEVEL ORGREATERSPILLWAY INVERT ELEVWATERSURFACECONTROL SECTIONS100'EXIT SECTORDAM.WITH THE CENTERLINE OF THESECTION HAS TO COINCIDEALIGNMENT OF THE CONTROL NEITHER THE LOCATION NORNOTE:PLANCHANNELAPPROACHEMBANKMENTBERMLCFLOW CONTROL SECTIONLEVEL PORTIONLCCLLCPROFILE ALONG CENTERLINERIP RAP LINED25'EMBANKMENTBERMFREEBOARD (1' MIN)EXTEND LINER 1' BELOW BOTTOM ELEV.SEE PLANS FOR LINER LENGTHSKIMMER/SEDIMENT BASINCONSTRUCTION AND MAINTAINCE PROCEDURESANTI-SEEP COLLAROUTLET PROTECTIONLa=9.0 FTW=4.5 FTd=18"6721(‘ &/$66%5,35$3TRASH RACKRISER = 24" CMPBARREL60 LF 18" CMP @ 0.0% MINSOLID EARTHEN DAMWEIR EL=197.5TOP EL= 199.0BOTTOM EL= 193.0PRINCIPAL SPILLWAY EL=197.03:1 MAXSLOPESNTS SEDIMENT BASIN #1 W/RISER STRUCTUREPOND EL= 197.0INV OUT= 194.0ANTI-SEEP COLLARCOMPACTED CLAY SOIL AROUNDBARREL AND COLLAR95% COMPACTION3:1 MAX SLOPE (TYP)3:1 MAX SLOPE (TYP)KEY TRENCH(3' BELOW EX. GROUND, 5'WIDE AT BOTTOM)1:1 6" SKIMMER (TYP)25,),&(‘ NTS SEDIMENT BASIN5.5' x 5.5' x 1.0' THICKCONCRETE BASEINV OUT=194.0NTS ROCK INLET PROTECTION File: C:\Users\DDS2\Desktop\Drafting and Design\2019\2019-23 Winchester Subdivsion\2020.04.22 - Winchester Subdivision CDs.dwg Print Date: 10/21/2020 DETAILS - EROSION CONTROLNTSDrawn by:Designed by:Reviewed by:Date:Scale:Sheet:Project Number:ofREVISIONS 20PROFESSIONAL ENGINEER'S SEAL WINCHESTER SUBDIVISION MTBJRTJRTSEPTEMBER 14, 2020ROCKFISH ROAD HOKE COUNTY, NORTH CAROLINA 143 Charlotte Avenue, Suite 104Sanford, North Carolina 27330(919) 777-6010 phonewww.jthomasengineering.comlicense no. C-338918 SEPT 2020: REVISED PER EC COMMENTSISSUEDFOR CONSTRUCTIONJ Thomas Engineering, Inc.civil engineering &planningJTE #: 20-010DDS#: 2019-238 OCT 2020: REVISED PER DRIVEWAY PERMIT COMMENT MOVED CURB TIE TO 6' FROM TRAVEL LANE21 OCT 2020: REVISED PER NCDOT COMMENTS, NCDEQPWS & NCDEQ STORMWATER PERMIT COMMENTS10' MINIMUMVARIESBB10 mil PLASTIC LININGWOOD FRAME SECURELYFASTENED AROUNDENTIRE PERIMETERWITH TWO STAKESTWO-STACKED2X12 ROUGHWOOD FRAMESTAKE(TYP)TYPE "ABOVE GROUND"WITH WOOD PLANKSVARIES10' MINIMUMAA3'LATH ANDFLAGGING ON3 SIDES10 mil PLASTIC LININGPLANNOT TO SCALESECTION A-ANOT TO SCALEBERMSANDBAGSANDBAG10 mil PLASTIC LININGBERMCONCRETEWASHOUTCONCRETE WASHOUTSIGN DETAIL(OR EQUIVALENT)PLYWOOD48"X24"PAINTED WHITEBLACK LETTERS6" HEIGHTLAG SCREWS36"36"WOOD POST3.5"X3.5"X8'STRAW BALESTRAW BALE(TYP)10 mil PLASTIC LININGVARIES10' MINIMUMBINDER WIRENATIVE MATERIAL(OPTIONAL)STAPLES(2 PER BALE)WOOD ORMETAL STAKES(2 PER BALE)SECTION B-BNOT TO SCALE10 mil PLASTIC LININGBBPLANNOT TO SCALETYPE "ABOVE GRADE"WITH STRAW BALES10 mil PLASTIC LININGSECTION B-BNOT TO SCALEPLANNOT TO SCALETYPE "BELOW GRADE"2"8"1.12" DIASTEEL WIRESTAPLEDETAILNOTES:1. ACTUAL LAYOUT TO BE DETERMINED IN THE FIELD.2. A CONCRETE WASHOUT SIGN SHALL BE INSTALLED WITHIN 30' OF THE TEMPORARY CONCRETE WASHOUT FACILITY.3. MATERIALS USED TO CONSTRUCT TEMPORARY CONCRETE WASHOUT FACILITIES SHALL BE REMOVED FROM THE SITE OF THE WORK AND DISPOSED OF OR RECYCLED.4. HOLES, DEPRESSIONS OR OTHER GROUND DISTURBANCE CAUSED BY THE REMOVAL OF THE TEMPORARY CONCRETE WASHOUT FACILITIES SHALL BE BACKFILLED, REPAIRED, AND STABILIZED TO PREVENT EROSION.5. MUST BE LOCATED >50 FT AWAY FROM INLETS/WATERWAYS UNLESS THERE IS NO OTHER PRACTICAL ALTERNATIVE.NTS CONCRETE WASHOUTFlow from undisturbed areaDIKEVAR.2' - 10'VAR.0' - 2'CROSS SECTIONAL VIEW2:1 MAX.2:1 MAX.12"NOTES:2' MIN.1.5' MIN1.DIVERSION TO BE USED UPSLOPE OF A CONSTRUCTION SITE TO PREVENT STORM RUNOFF FROM ENTERING THE DISTURBED AREA.2.IMMEDIATELY LINE AND STABILIZE BEFORE ANY DOWNSLOPE GRADING BEGINS (STABILIZATION MUST OCCUR BEFORE ISSUANCE OF ACERTIFICATE OF COMPLIANCE). STABILIZATION METHOD IS BASED ON VELOCITY OF OFFSITE DRAINAGE.3.DIVERSIONS SHOULD ONLY BE USED FOR DRAINAGES 5 ACRES OR LESS.4.ANY SEDIMENT LADEN WATER PRIOR TO STABILIZATION OF THE DIVERSION MUST BE DIVERTED INTO AN APPROVED EROSION AND SEDIMENTCONTROL BMP. CLEAN WATER SHOULD EMPTY INTO AN APPROVED OUTLET DEVICE.Disturbed AreaNTS CLEANWATER DIVERSIONSIDE SLOPES3 : 1 (MAXIMUM)NTS TEMPORARY LINING FOR TEMPORARY/PERMANENTDIVERSION DITCHC20NTS SILT BAGMAINTENANCE:1. SILT BAG MUST BE MONITORED AT ALL TIMES DURING USE (OVER-FILLING MAY CAUSE RUTURE).2.FLOW AND REMOVAL RATES VARY BASED ON PARTICLESIZE/SEDIMENTATION COMPOSITION ADJUST PUMP FLOW BASED ONTHESE FACTORS.3. ENSURE SEDIMENT CONTROL STONE IS CLEAN PRIOR TO USE OR BETWEEN SILT BAG EXCHANGE.4. REPLACE SILT BAG ONCE IT BECOMES HALF FULL OF SEDIMENT.