Loading...
HomeMy WebLinkAboutNC0072664_Regional Office Historical File Pre 2018 (82)Shmmml 22 June 2018 Division of Water Resources Attention: Central Files North Carolina Department of Environmental Quality 1617 Mail Service Center Raleigh, North Carolina 27699-1617 Subject: NPDES Permit No. NCO072664 e-DMR Hardcopies — May 2018 Shurtape Technologies, LLC - Stony Point Plant Alexander County RECEIVED JUN 2 6 2018 CENTRP,t_ FILES DWR SECTION RECEIVM/NC17ENR/I)WR JUL, 2 2018 WQROS MOORESVILLE REGIONAL OFFICE The DMR for the referenced facility for the above -referenced month was submitted via the North Carolina e-DMR system. Please find attached the signed hardcopies (one original and one copy) of the e-DMR submittal. If you have questions, please contact me at (828) 267-8212. Respectfully yours, Jerry W. Eplin, PE Environmental Manager enclosures cc: Ed Hoolehan w/ enclosures Doug Hall w/ enclosures Shurtape Technologies, LLC P.O. Box 1530, Hickory, NC 28603 • Phone: 828.322.2700 • Toll -Free: 888.442.8273 IT NO.: NCO072664 FACILITY NAME: Stony Point Plant OWNER NAME: Shurtape Technologies, LLC GRADE: WW-3 eDMR PERIOD: 05-2018 (May 2018) PERMIT VERSION: 4.0 CLASS: WW-2 ORC: Douglas Ray Hall ORC HAS CHANGED: No VERSION: 1.0 PERMIT STATUS: Active COUNTY: Alexander ORC CERT NUMBER: 996520 STATUS: Processed SAMPLING LOCATION: EFFLUENT DISCHARGE NO.: 001 NO DISCHARGE*: NO F u H� _ 5 E r E a E F < - 0 E P E _ o U C a 50050 00010 00400 50060 C0310 C0610 C0530 31616 00300 Weekly 5Xweek Weekly 2Xweek Weekly Weekly Weekly Weekly Weekly Instantaneous Grab Grab Grab Grab Grab Grab Grab Grab FLOW TENIP-C pH CHLORINE BOD - Cone NH3-N-Cone TSS-Cant FCOLI BR DO 2400 clock Hra 2400 clack Hm Y/B/N mgd deg c so ug/l mg/I mg/1 mg/I #/100ml mg/I t 0545 2 Y 16 2 0547 2 Y 0.0017 16 7.3 <20 2.2 <0.2 <2.5 <1 7.6 3 0518 2 Y 17 4 0520 2 Y 18 5 1515 1 Y 19 6 1845 1 Y 19 7 0512 2 Y 0.0007 19 7.4 < 20 < 2 < 0.2 < 2.5 < 1 7.2 S 0532 12 Y 1 19 9 0513 2 Y 19 < 20 10 0518 2 Y 19 11 0508 2 - Y 20 12 1113 1 Y 20 13 1225 1 Y 20 - 14 0513 2 Y 21 < 20 15 0510 2 Y 21 16 0516 2 Y 0.0011 21 7.6 <20 7.8 <0.2 <2.5 <1 7.6 17 0518 2 Y 21 18 0528 2 Y 22 19 1726 1 Y 22 20 1411 1 Y 22 21 0518 2 Y 21 < 20 22 0503 2 Y 21 23 0516 2 Y 0.0014 22 7.7 <20 11.6 <0.2 <2.5 <1 8 24 0524 2 Y 23 25 1 0510 12 Y 1 122 26 1116 1 Y 23 27 1903 1 Y 23 28 1227 2 Y 23 < 20 29 0519 2 Y 23 30 0520 2 Y 0.002 23 7.6 < 20 10.9 < 0.2 4.4 < 1 6.3 31 10503 2 Y 23 Monthly Average Limit 0.01 30 30 200 Monthly Avcmgc 0.00138 20.580645 0 6.5 0 0.88 1 7.34 Daily bla:imum: 0.002 23 7.7 0 11.6 0 4.4 0 8 Daily Minimum: 0.0007 16 7.3 0 0 0 0 10 16.3 ****No Reporting Reason: ENFRUSE = No Flow-Reuse/Recycle; ENVWTHR = No Visitation -Adverse Weather; NOFLOW = No Flow; HOLIDAY = No Visitation -Holiday NPDES PERMIT NO.: NCO072664 PERMIT VERSION: 4.0 PERMIT STATUS: Active FACILITY NAME: Stony Point Plant OWNER NAME: Shurtape Technologies, LLC GRADE: WW-3 eDMR PERIOD: 05-2018 (May 2018) CLASS: WW-2 ORC: Douglas Ray Hall ORC HAS CHANGED: No VERSION: 1.0 COUNTY: Alexander ORC CERT NUMBER: 996520 STATUS: Processed SAMPLING LOCATION: DOWNSTREAM DISCHARGE NO.: 001 A E Fr. 8 m a Z 00300 Weekly Grab DO 2400 clock MgA / 2 0742 10.2 3 4 5 6 7 0754 9.1 8 9 10 11 12 13 14 is 16 0755 7.8 17 18 19 20 21 22 23 0802 8.5 24 25 26 27 28 29 30 0714 8.4 31 Monthly A—ge Limit. ble.thly Average 8.8 Daily Maximum: 10.2 .. Daily Minimum: 7.8 ****No Reporting Reason: ENFRUSE = No Flow-Reuse/Recycle; ENV WTHR = No Visitation —Adverse Weather; NOFLOW = No Flow; HOLIDAY =No Visitation —Holiday WT NO.: NCO072664 FACILITY NAME: Stony Point Plant OWNER NAME: Shurtape Technologies, LLC GRADE: WW-3 eDMR PERIOD: 05-2018.(May 2018) PERMIT VERSION: 4.0 CLASS: WW-2 ORC: Douglas Ray Hall ORC HAS CHANGED: No VERSION: 1.0 PERMIT STATUS: Active COUNTY: Alexander ORC CERT NUMBER: 996520 STATUS: Processed SAMPLING LOCATION: EFFLUENT DISCHARGE NO.: 001 NO DISCHARGE*: NO (Continue) o E F _ E E r E ? E H _ PIE a Y o` H in C A a C0600 C0665 Quarterly Quarterly Grab Grab TOTAL N - Cone TOTALP-Cone 2400 clock Hrs 2400 clock H. YB/N mg/l mg/l 1 0545 2 Y 2 0547 2 Y 3 0518 2 Y 4 0520 2 Y 5 1515 I Y 6 1845 I Y 7 0512 2 Y 8 0532 2 Y 9 0513 2 Y 10 0518 2 Y it 10508 2 1 Y 12 1113 1 Y 13 1225 1 Y 14 0513 2 Y 15 0510 2 Y 16 0516 2 Y 17 0518 2 Y 18 0528 2 Y 19 1726 1 Y 20 1411 1 Y 21 0518 2 Y 22 0503 2 Y 23 0516 2 Y 7.! 10524 12 Y 25 0510 2 Y 26 1116 1 Y 27 1903 1 Y 28 1227 2 Y 29 0519 2 Y 30 0520 2 Y 31 0503 12 1 Y Monthly Average Limit: Monthly Average: Daily Maximum: Daily Minimum: **** No Reporting Reason: ENFRUSE = No Flow-Reuse/Recycle; ENVWTHR=No Visitation— Adverse Weather; NOFLOW=No Flow; HOLIDAY=NoVisitation— Holiday NPDES PERMIT NO.: NCO072664 PERMIT STATUS: Active FACILITY NAME: Stony Point Plant OWNER NAME: Shurtape Technologies, LLC GRADE: WW-3 eDMR PERIOD: 05-2018 (May 2018) PERMIT VERSION: 4.0 CLASS: WW-2 ORC: Douglas Ray Hall ORC HAS CHANGED: No VERSION: 1.0 COUNTY: Alexander ORC CERT NUMBER: 996520 STATUS: Processed SAMPLING LOCATION: UPSTREAM DISCHARGE NO.: 001 v A E F E n c �i a` a z 00300 Weekly Grab DO 2 400 clod: Mg/l 1 2 0749 9.7 3 5 6 7 0803 8.6 8 9 10 11 12 13 14 is 16 0803 7.2 17 18 19 20 21 22 23 0810 7.8 24 25 26 27 28 29 30 0724 8.3 31 Monthly Avenge Limit: Monthly Avenge: $32 Daily Mnimum• ' 9.7 Daily Minimum: 7.2 •••'NoReporting Reason: ENFRUSE=NoFlow-Reuse/Recycle; ENVWTHR=No Visitation— Adverse Weather; NOFLOW=No Flow; HOLIDAY=NoVisitation— Holiday IIT NO.: NCO072664 FACILITY NAME: Stony Point Plant OWNER NAME: Shurtape Technologies, LLC GRADE: WW-3 eDMR PERIOD: 05-2018 (May 2018) COMPLIANCE STATUS: Compliant PERMIT VERSION: 4.0 CLASS: W W-2 ORC: Douglas Ray Hall ORC HAS CHANGED: No VERSION: 1.0 CONTACT PHONE #: 8282678919 PERMIT STATUS: Active COUNTY: Alexander ORC CERT NUMBER: 996520 STATUS: Processed SUBMISSION DATE: 06/21/2018 �/ " I —06/21/2018 ORC/Certifie Signature: Doug Hall E-Mail:dhall@shurtape.com Phone #:828-322-2700 Date By this signature, I certify that this report is accurate and complete to the best of my knowledge. The permittee shall report to the Director or the appropriate Regional Office any noncompliance that potentially threatens public health or the environment. Any information shall be provided orally within 24 hours from the time the permittee became aware of the circumstances. A written submission shall also be provided within 5 days of the time the permittee becomes aware of the circumstances. If the facility is noncompliant, please attach a list of corrective actions being taken and a time -table for improvements to be made as required by part II.E.6 of the NPDES permit. 06/21/2018 Perm ittwC1`S"ubm itter Signature:*** Edward J Hoolehan E-Mail:ehoolehan@shurtape.com Phone #:828-322-2700 Date Permittee Address: 8510 NC Hwy 90 E Stony Point NC 28678 Permit Expiration Date: 03/31/2019 I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who managed the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations. CERTIFIED LABORATORIES LAB NAME: WaterTech Lab Inc. and Shurtape on -site lab fpr field parameters CERTIFIED LAB #: # 50 and #5087 PERSON(s) COLLECTING SAMPLES: Douglas Hall PARAMETER CODES Parameter Code assistance may be obtained by calling the NPDES Unit (919) 807-6300 or by visiting http://portal.ncdenr.org/web/wq/swp/ps/npdes/forms. FOOTNOTES Use only units of measurement designated in the reporting facility's NPDES permit for reporting data. * No Flow/Discharge From Site: Check this box if no discharge occurs and, as a result, there are no data to be entered for all of the parameters on the DMR for entire monitoring period. ** ORC on Site?: ORC must visit facility and document visitation of facility as required per 15A NCAC 8G .0204. ** Signature of Permittee: If signed by other than the permittee, then delegation of the signatory authority must be on file with the state per 15A NCAC 2B .0506(b)(2)(D).