January 25, 2018
Mr. Mark Hawes
Shurtape Technologies, LLC.
P.0 Box 1530
Hickory, NC 28603
Subject: Compliance Inspection
Stony Point Tape Plant
NPDES Permit No. NCO072664
Alexander County
Dear Mr. Hawes:
1 R'COOPER
LL,O-y
Governor
MICHAEL S. REGAN
Secretary
LINDA CULPEPPER
Interim Director
Enclosed is a copy of the Compliance Inspection report for the inspection conducted at the
subject facility on January 24, 2018, by Ori Tuvia. Your cooperation during the site visit was much
appreciated. Please advise the staff involved with this NPDES Permit by forwarding a copy of the
enclosed report.
The report should be self-explanatory; however, should you have any questions concerning
this report, please do not hesitate to contact Ori Tuvia at (704) 235-2190, or at
ori.tuvia@ncdenr.gov.
Cc: NPDES Unit
MRO Files
Sincerely,
Ori Tuvia, Environmental Engineer
Mooresville Regional Office
Division of Water Resources, DEQ
Mooresville Regional Office
United States Environmental Protection Agency
Form Approved.
EPA Washington, D.C. 20460
OMB No. 2040-0057
Water Compliance Inspection Report
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type
1 IN 1 2 15 I 3 I NCD072664 I11 121 17/01/24 I17 181,.1 19 i G i 201 I
211111 1=1 I I I I II I I LI I I I I I I I I I I I I I I .I I I I I II I I I 1 1 166
I
Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved
67 1.0 701a j 71 I„ I 72 ti 731 �74. 751 I I I I l80
I-J l-J I I I
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
Entry Time/Date
Permit Effective Date
POTW name and NPDES permit Number)
09:00AM 17/01/24
14/06/01
Stony Point Plant
Exit Time/Date
Permit Expiration Date
8510 NC Hwy 90 E
10:20AM 17/01/24
19/03/31
Stony Point NC 28678
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
Other Facility Data
Douglas Ray HaIUORC/828-267-8919/
Name, Address of Responsible Official/Title/Phone and Fax Number
Contacted
Mark E Hawes,PO Box 1530 Hickory NC 286031530/Director of Environment &
No
Safety/828-267-8428/8778599746
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Permit Flow Measurement Operations & Maintenance Records/Reports
Self -Monitoring Program �. Sludge Handling Disposal E.Facility Site Review Effluent/Receiving Waters
Laboratory
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date
Ori A Tuvia � MRO WQ//704-663-1699/
Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date
W. Corey Basinger MRO WQ//704-235-2194/
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. n
Page#
NPDES yr/mo/day Inspection Type 1
31 NCo0726sa I11 121 17/01/24 117 18
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
Page#
Permit: NCO072664
Inspection Date: 01/24/2017
Permit
Owner - Facility: Stony Point Plant
Inspection Type: Compliance Evaluation
(If the present permit expires in 6 months or less). Has the permittee submitted a new
application?
Is the facility as described in the permit?
# Are there any special conditions for the permit?
Is access to the plant site restricted to the general public?
Is the inspector granted access to all areas for inspection?
Yes No NA NE
❑ ❑ M ❑
❑
❑
❑
❑
■
❑
❑
■
❑
❑
❑
■
❑
❑
❑
Comment: The subject permit expires on 3/31/2019.
Air washer and cooling tower discharges were rerouted from the WWTP in 2012 and are
now directly discharged under NCG500323
Record Keepinq
Yes No NA NE
Are records kept and maintained as required by the permit?
0
❑
❑
❑
Is all required information readily available, complete and current?
0
❑
❑
❑
Are all records maintained for 3 years (lab. reg. required 5 years)?
E
❑
❑
❑
Are analytical results consistent with data reported on DMRs?
0
❑
❑
❑
Is the chain -of -custody complete?
E
❑
❑
❑
Dates, times and location of sampling
Name of individual performing the sampling
Results of analysis and calibration
Dates of analysis
Name of person performing analyses
Transported COCs
Are DMRs complete: do they include all permit parameters?
M
❑
❑
❑
Has the facility submitted its annual compliance report to users and DWQ?
❑
❑
❑
(If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator
❑
❑
0
❑
on each shift?
Is the ORC visitation log available and current?
0
❑
❑
❑
Is the ORC certified at grade equal to or higher than the facility classification?
0
❑
❑
❑
Is the backup operator certified at one grade less or greater than the facility classification?
0
❑
❑
❑
Is a copy of the current NPDES permit available on site?
M
❑
❑
❑
Facility has copy of previous year's Annual Report on file for review?
❑
❑
M
❑
Comment: The permittee's records and logbooks were very organized and well maintained and records
requested during the inspection were readily available. DMRs, COCs, Maintenance logs and
calibration logs were reviewed for January 2017 through September 2017.
Page# 3
Permit: NCO072664 Owner -Facility:
Stony Point Plant
Inspection Date: 01/24/2017 Inspection Type:
Compliance Evaluation
Laboratory
Yes
No
NA NE
Are field parameters performed by certified personnel or laboratory?
M
❑
❑
❑
Are all other parameters(excluding field parameters) performed by a certified lab?
M
❑
❑
❑
# Is the facility using a contract lab?
❑
❑
❑
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees M ❑ ❑ ❑
Celsius)?
Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? ❑ ❑ M ❑
Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees? ❑ ❑ M ❑
Comment: On -site analvses (temperature. DH, dissolved oxvoen and total residual chlorine) are
performed under field laboratory certification #5087. Water Tech Labs, Inc. (Certification
#50) performs all remaining permit -required effluent analyses as well as the MLSS and
MLVSS process control analyses. The field instrumentation used on site appeared to be
properly calibrated and documented. The meters are calibrated/verified twice per year by
Water Tech Labs, Inc. N/8/2018). The temperature reported on the DMRs is taken from the
pH meter.
Effluent Samplinq
Yes
No NA NE
Is composite sampling flow proportional?
❑
❑
❑
Is sample collected below all treatment units?
M
❑
❑
❑
Is proper volume collected?
M
❑
❑
❑
Is the tubing clean?
❑
❑
M
❑
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees
0
❑
❑
❑
Celsius)?
Is the facility sampling performed as required by the permit (frequency, sampling type
M
❑
❑
❑
representative)?
Comment: The permit requires orab samples for all reauired parameters. All effluent samDles are kept
on ice in a cooler until transfer to the contracted analytical laboratory is completed.
Upstream / Downstream Sampling Yes No NA NE
Is the facility sampling performed as required by the permit (frequency, sampling type, and 0 ❑ ❑ ❑
sampling location)?
Comment:
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping? M ❑ ❑ ❑
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable - ❑ ❑ ❑
Solids, pH, DO, Sludge Judge, and other that are applicable?
Page# 4
Permit: NCO072664
Inspection Date: 01/24/2017
Owner -Facility: Stony Point Plant
Inspection Type: Compliance Evaluation
Operations & Maintenance Yes No NA NE
Comment: The permittee conducts process control sampling of PH, dissolved oxygen, MLSS, MLVSS,
and settleability in the operation of the VVVVTP. The air washer and cooling tower
discharges were rerouted from the WVVTP in 2012 and are now directly discharged under
NCG500323
Bar Screens
Yes No NA NE
Type of bar screen
a.Manuat
b.Mechanical
❑
Are the bars adequately screening debris?
❑
❑
❑
Is the screen free of excessive debris?
0
❑
❑
❑
Is disposal of screening in compliance?
N
❑
❑
❑
Is the unit in good condition?
0
❑
❑
❑
Comment: Screenings are disposed with the WWTP sludge by Miller's Septic Service.
Aeration Basins
Yes No NA NE
Mode of operation
Ext. Air
Type of aeration system
Diffused
Is the basin free of dead spots?
N ❑
❑
❑
Are surface aerators and mixers operational?
❑ ❑
E
❑
Are the diffusers operational?
0 ❑
❑
❑
Is the foam the proper color for the treatment process?
0 ❑
❑
❑
Does the foam cover less than 25% of the basin's surface?
N ❑
❑
❑
Is the DO level acceptable?
❑
❑
❑
Is the DO level acceptable?(1.0 to 3.0 mg/1)
❑ ❑
❑
Comment:
Secondary Clarifier
Yes
No NA NE
Is the clarifier free of black and odorous wastewater?
0
❑ ❑
❑
Is the site free of excessive buildup of solids in center well of circular clarifier?
❑
❑ 0
❑
Are weirs level?
❑ ❑
❑
Is the site free of weir blockage?
0
❑ ❑
❑
Is the site free of evidence of short-circuiting?
N
❑ ❑
❑
Is scum removal adequate?
0
❑ ❑
❑
Is the site free of excessive floating sludge?
N
❑ ❑
❑
Page#
5
Permit: NC0072664 Owner -Facility:
Stony Point Plant
Inspection Date: 01/24/2017 Inspection Type:
Compliance Evaluation
Secondary Clarifier
Yes No NA NE
Is the drive unit operational?
❑
❑
M
❑
Is the return rate acceptable (low. turbulence)?
0
❑
❑
❑
Is the overflow clear of excessive solids/pin floc?
M
❑
❑
❑
Is the sludge blanket level acceptable? (Approximately '/< of the sidewall depth)
E
❑
❑
❑
Comment:
Disinfection -Tablet
Yes
No NA NE
Are tablet chlorinators operational?
❑
❑
❑
Are the tablets the proper size and type?
0
❑
❑
❑
Number of tubes in use?
2
Is the level of chlorine residual acceptable?
0
❑
❑
❑
Is the contact chamber free of growth, or sludge buildup?
0
❑
❑
❑
Is there chlorine residual prior to de -chlorination?
0
❑
❑
❑
Comment:
De -chlorination Yes No NA NE
Type of system ? Tablet
Is the feed ratio proportional to chlorine amount (1 to 1)? ❑ .❑ ❑
Is storage appropriate for cylinders? ❑ ❑ ❑
# Is de -chlorination substance stored away from chlorine containers? ❑ ❑ ❑
Comment:
Are the tablets the proper size and type? M ❑ ❑ ❑
Are tablet de -chlorinators operational? M ❑ ❑ ❑
Number of tubes in use? 2
Comment:
Aerobic Digester
Yes
No NA NE
Is the capacity adequate?
0
❑
❑
❑
Is the mixing adequate?
0
❑
❑
❑
Is the site free of excessive foaming in the tank?
M
❑
❑
❑
# Is the odor acceptable?
M
❑
❑
❑
# Is tankage available for properly waste sludge?
M
❑
❑
❑
Page# 6
Permit: NCO072664
Inspection Date: 01/24/2017
Aerobic Digester
Owner - Facility: Stony Point Plant
Inspection Type: Compliance Evaluation
Yes No NA NE
Comment: The permittee aerates the 2 000-gallon sludge holding tank within the WWTP. The sludge is
taken to the Taylorsville WWTP by Miller's Septic Service
Effluent Pipe Yes No NA NE
Is right of way to the outfall properly maintained? No ❑ ❑
Are the receiving water free of foam other than trace amounts and other debris? 0 ❑ ❑ ❑
If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ 0 ❑
Comment:
Flow Measurement - Effluent
Yes No NA NE
# Is flow meter used for reporting?`
❑
0
❑
❑
Is flow meter calibrated annually?
❑
❑
0
❑
Is the flow meter operational?
❑
❑
0
❑
(If units are separated) Does the chart recorder match the flow meter?
❑
❑
0
❑
Comment: Permittee uses the bucket/stop watch method of determining effluent flow.
Page# 7