Loading...
HomeMy WebLinkAboutNC0026271_Regional Office Historical File Pre 2018 (46)Performance Annual Report Town of Taylorsville (2008-2009) U L)I. General InformationRE 4r'0L11V Facility System Name: Taylorsville Wastewater Treatment Plant & Collection System Responsible Entity: Town of Taylorsville 67 Main Ave Dr, Taylorsville NC, 28681 Persons in Charge/Contacts: Brian Eades WWTP-ORC David Robinette -Public Works Director/CS ORC Applicable Permit(s) : NC0026271 WWTP & WQCSU0135 Collection System J U L - 6 2009 DEN R . WATER QUALITY POINT SOURCE BRANCH Description of Collection System & Treatment Process: The Town of Taylorsville's Collection System consists of approximately 22 miles of sewer pipe and 22 regularly maintained pump stations. Domestic sewage Flows into an 830,000 gallon per day Treatment Facility where it is properly treated for discharge into the Lower little River. The WWTP consists of one micro -screening device for solids removal, two (2) 415,000 gallon aeration basins for GODS and NH removal, two (2) 4S foot diameter Clarifiers for settling solids, two (2) CL2 chambers for water disinfection, and one (1) S02 chamber to reduce CL2 levels in treated water. Also, there are four (4) aerobic digester which treat an average of 1.2 million gallons of sludge per year for land application. Each process is operate efficiently throughout this fiscal year. The Effluent has been compliant with state regulations each month (with the exception being the month of 12/2008 when TSS levels were marginally non -compliant due to heavy rainstorms). It. Performance; Text summary of System Performance for the fiscal year 2008-2009. The sewer system is effectively maintained and operated at all times to orevent improper discharge to land or surface waters. map of the sewer system has been developed and actively updated An operation and maintenance plan has been developed and Implemented A general observation of the entire sewer system Is conducted at a least one per year. Inspection and maintenance records are kept for a period of three (3) years. Also, any overflows or basses (SSO's) are reported to our division regional office in accordance to iSA NCAC 2B.0506(a) as well as public notification (as needed) The Town's Sewage Collection System operated efficiently with only minor clogs that were quickly unstop ed to prevent SSO's The WWTP successfully removed over 95% of 9manic biological contaminants and over 90% of the settable solids from the wastewater throughout the vear. and produced a clear -clean water to reintroduce Into the river. There were four (4) occurrences of sewer overflow during the fiscal Year 2008 2009 All incidents were reported to the State ivi ' n of !Hater Quality IDWQI in -Mooresville as regulations-require--and-repairs -and cleanup performed also according to - stringent state re ulatlons. III. Notifications: This report will be published in the local newspaper and the public will be advised that copies will be available at the Town Hall. IV. Certification: ava'I� ab� 11ity. , �,�t�f,., :;,:-. = ; ,,�.., r; ; rst'•-,_ �; June 29, 2009 David Robinette Public Works Director J U L 1 0 2009 Town of Taylorsvill J