Subject: Compliance Inspection
Schneider Mills WWTP
NPDES Permit No. NCO034860
Alexander County
Dear Mr. Swinnie:
LINDA CULPEPPER
Interim Director
r
Enclosed is a copy of the Compliance Inspection for the inspection conducted at the
subject facility on November 3, 2016, by Ori Tuvia.. Darren Webb's cooperation during the site
visit was much appreciated. Please advise the staff involved with this NPDES Permit by
forwarding a copy of,the enclosed report.
The following areas of concern were observed during the inspection:
1) ORC Must Record the beginning and end time of composite sampling.
2) At the time of the inspection the flow meter values did not match the calculated value,
ORC will need to farther investigate.
The report should be self-explanatory; however, should you have any questions,
concerning this report, please do not hesitate to contact Ori Tuvia at (704) 235-2190, or at
ori.tuvia@ncdenr.gov.
Cc: NPDES Unit
MRO Files
Sincerely,
Ori Tuvia, Environmental Engineer
Mooresville Regional Office
Division of Water Resources,__DEQ
Mooresville Regional Office
Location: 610 East Center Ave., Suite 301 Mooresville, NC 28115
Phone: (704) 663-16991 Fax: (704) 663.60401 Customer Service:1.877-623-6748
United States Environmental Protection Agency
Form Approved.
EPA Washington, D.C. 20480
OMB No. 2040-0057
Water Compliance Inspection Report
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code NPDES yr/mo/day Inspection Type Inspector Fee Type
1 IN I 2 15 I 3 I NCO034860 I11 12 17/11/14 17 18 I,• I 19 I s l 20I I
211;I I I, I I I l l l l i, I I I I I I I I I I I I I I I I I I I I I I I I I I I I I r6
I
Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved
67
1.0 70IQ I 71 IN I 72 IJ N 72i I I74 75.
IJ I_1 I I
80
Section B: FacilityData
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include -
Entry Time/Date
Permit Effective Date
POTW name and NPDES permit Number)
09:30AM 17/11/14
15/11/03
Schneider Mills WWTP
1170 NC Hwy 16 N
Exit Time/Date
Permit Expiration Date
Taylorsville NC 28681
11:30AM 17/11/14
20/07/31
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
Other Facility Data
Darren David Webb/ORC/828-632-8181/
Name, Address of Responsible Official/Title/Phone and Fax Number
Contacted
Chip Swinnie,PO Box 519 Taylorsville NC 286810519/Plant Manager/828-632-8181/
No
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Permit Flow Measurement Operations & Maintenance Records/Reports
N.Self-Monitoring Program N Sludge Handling Disposal Facility Site Review Effluent/Receiving-Waters,
Laboratory
Section D: Summary of Finding/Comments (Attach, additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date
Od A Tuvia MRO WO//704-663-1699/
wer Agency/Office/Phone and Fax Numbers Date
Signature of ManagemNMV
Andrew Pitner Cl WQ//704-663-1699 Ext.21 (S 1 `7
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete.
Page#
r
Page# 2
0
Permit: NCO034860 Owner -Facility: Schneider Mills WWTP
Inspection Date: 11/14/2017 Inspection Type; Compliance Evaluation
Permit
(If the present permit expires in 6 months or less). Has the permittee submitted a new
application?
Is the facility as described in the permit?
# Are there any special conditions for the permit?
Is access to the plant site restricted to the general public?
Is the inspector granted access to all areas for inspection?
Comment: The subject permit expires on 7/31/2020.
Record Keeoina
Are records kept and maintained as required by the permit?
Is all required information readily available, complete and current?
Are all records,maintained for 3 years (lab. reg. required 5 years)?
Are analytical results consistent with data reported on DMRs?
Is the chain -of -custody complete?
Dates, times and location of sampling
Name of individual performing the sampling
Results of analysis and calibration
Dates of analysis -
Name of person performing analyses
Yes No NA 'NE
❑ ❑ N-❑
■
❑
❑
❑
❑11
❑
❑
■
❑
❑
❑
0
❑
❑
❑
Yes No .NA NE
❑ ❑ ❑
❑
❑
❑
❑
❑
❑
0
❑
❑
❑
■
..❑
❑
❑
Transported COCs
Are DMRs complete: do they include all permit parameters? .❑ ❑ ❑
Has the facility submitted its annuai compliance report to users and DWQ? ❑ ❑ -0 ❑
(If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator ❑ ❑ ❑
on each shift?
Is the ORC visitation log. available and current?
. ❑
❑
Is the ORC certified at grade equal to or higher than the facility classification?
❑
❑
❑
Is the backup operator certified at one grade less or greater than the facility classification?
N
❑
Cl
11
Is a copy of the current NPDES permit available on site?
❑
❑
❑
Facility has copy of previous year's Annual Report on file for review?
❑
❑
❑
Comment:
sampling.
Page# 3
I
Permit: NCO034860 Owner -Facility: Schneider Mills WWTP
Inspection Date: 11/14/2017 Inspection Type: Compliance Evaluation
Laboratory
Yes No NA NE
Are field parameters performed by certified personnel or laboratory?
❑
❑
❑
Are all other parameters(excluding field parameters) performed by a certified lab?
❑
❑
❑
# Is the facility using a contract lab?
E
❑
❑
❑
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees
N
❑
❑
❑
Celsius)?
Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees?
0
❑
Incubator (BOD) set to 20.0 degrees Celsius +/-1.0 degrees?
❑
❑
❑
Comment: On -site field analvses (dissolved oxvgen, pH, temperature, total residual chlorine) are
performed under the Company's field laboratory certification #5012. Water Tech Labs
(BOD, TSS, ammonia, nutrients) and R & A Laboratories, Inc. (toxicity
and metals) .have
also been contracted to provide analytical support
Effluent Sampling
Yes No NA NE
Is composite sampling flow proportional? .
❑
❑
❑
Is sample collected, below all treatment units?
E
❑
❑
❑
Is proper volume collected?
0
❑
❑
❑
Is the tutting clean?-
0
❑
❑
❑
# Is proper temperature -set for sample storage (kept at less than or equal to 6.0 degrees
E
❑
❑
❑
Celsius)?
Is the facility sampling performed as required by the permit (frequency, sampling type
E
❑
❑
❑
representative)?
Comment: The subiect Dermit'reauires both composite and Arab effluent samples. The Division
improved a variance'to collect time -based composite samples on 5/26/1998 provided that
the flows do not vary by more than 30%. The samgler was collecting 300 nil. aliquot every
twenty minutes with an internal temperature of less than four degrees Celsius.
Upstream % Downstream Sampling Yes No. NA NE
Is the facility sampling performed as required by the permit (frequency, sampling type, and ❑ ❑ - ❑
sampling location)?
Comment:
Operations & Maintenance Yes No NA NE
` Is the plant generally clean with acceptable housekeeping? ❑ ❑ ❑
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable N ❑ ❑ ❑
Solids, pH, DO, Sludge Judge, and other that are applicable?
Comment: The wastewater facility appeared to be properly operated and well maintained. The ORC
incorporates a comprehensive process control Program with all measurements being
properly documented and maintained on -site.
Page# 4
F
Permit: NCO034860 Owner - Facility: Schneider Mills WWTP
Inspection Date: 11/14/2017 Inspection Type: Compliance Evaluation
Bar Screens
Yes "No NA NE
Type_ of bar screen
a.Manual
b.Mechanical
❑
Are the bars adequately screening debris?
E
❑
❑
❑
Is the screen free of excessive debris?
0
❑
❑
0-
Is disposal of screening in compliance?
N❑
❑
❑
Is the unit in good condition?
❑
0
❑
Comment: Bar screenings are disposed at the Alexander County Landfill.
Flow Measurement - Influent
Yes No NA NE
# Inflow meter used for reporting?
A
❑
'❑
11,
Is flow meter calibrated annually?
.
❑
❑
❑, .."
Is.the flow meter operational?
0
❑
❑
❑
(If units are separated) Does the chart recorder match the flow meter?
❑
❑
N
❑
Comment: The influent flow meter (Outfall 001) is calibrated twice Der year and was last calibrated by
the number of backwash events per day.
,Aeration Basins
Mode of operation
Type of aeration system
Is the basin free of dead spots?
Are surface aerators and mixers operational?
Are the diffusers operational?
Is the foam the proper color for the treatment process?
Does the foam cover less than 25% of the basin's surface?
Is the DO level acceptable?
Is the DO level acceptable?(1.0 to 3.0 mg/1)
Yes No NA NE_
Ext. Air
Surface
■
❑
❑
❑
. ❑
❑
■
❑•
N.
❑
❑
❑
■
❑
❑
❑
■
❑
❑
❑
❑
❑
■
❑
Comment: Aqueous lime and soda ash' are added to maintain appropriate pH/alkalinity levels. The
ORC al§o adds food (BOD)/nutrient (nitrogen and phosphorus) supplements and selective
microrganisms to maintain the biological treatment process.
Secondary Clarifier
Yes No NA NE
Page# 5
I
Permit: NC0034860 Owner - Facility: Schneider Mills WWiP
Inspection Date: 11/14/2017.: Inspection Type: Compliance Evaluation
Secondary Clarifier
Yes No NA NE
Is the clarifier free of black and odorous wastewater?
0
❑
E13
❑
Is the site free of excessive buildup of solids in center well of circular clarifier?
E.
❑
11
❑
Are weirs level?
0. ,
❑
❑
Is the site free of weir blockage?
N.
❑
0
.❑
Is the site free of evidence of short-circuiting?
0
❑
❑
❑
-is scum removal adequate?
❑
.0 .
❑
Is. the site free of excessive floating sludge?
N ,
❑
❑
❑
Is the drive unit operational?
0
❑
❑
❑
Is the return rate acceptable (low turbulence)?
❑
❑
❑
Is the overflow, clear of excessive. solids/pin floc?
. ❑
❑
. E]
Is the sludge blanket level acceptable? (Approximately %.of the sidewall depth)
0
❑
❑
0
Comment: Polymer is added to the clarifier influent to enhance settling.
Pumps-RAS-WAS
Yes No NA NE
Are pumps in place?
❑
❑
❑
Are pumps operational .. >
❑
❑
Are there adequate spare parts and supplies on site?
E]
❑
❑
Comment:
Effluent Pipe
Is right of way to the outfall properly maintained?
Are the receiving water free of foam other than trace amounts and other debris?
If effluent (diffuser pipes are required) are they operating properly?
Comment: At the time of the inspection the -effluent appeared to be clear.
Aerobic Digester
Is the capacity adequate? 1,
Is the mixing ,adequate?
Is the site free of excessive foaming in the tank?
#. Is the odor acceptable?
# Is tankage available for properly waste "sludge?
Comment:
Yes No NA NE
■
'❑
❑
-❑
0,❑--❑
El
El
❑
❑
Yes No NA NE •
❑ ❑ ❑
❑' ❑ ❑
El El ❑ ❑
■,❑ ❑ 0
❑ ❑ ❑
Page# 6
Permit: NC0034860
Inspection Date: 11/14/2017
Owner -Facility: Schneider Mills WWTP
Inspection Type: Compliance Evaluation
Drying Beds
Is there adequate drying bed space?
Is the sludge distribution on drying beds appropriate?
Are the drying beds free of vegetation?
# Is the site free of dry sludge remaining in beds?
Is the site free of stockpiled sludge?
Is the filtrate from sludge drying beds returned to the front of the plant?
# Is the sludge disposed of through county landfill?
# Is the sludge land applied?
(Vacuum filters) Is polymer mixing adequate?
Yes No NA NE
■ ❑ ❑ ❑
■ ❑ ❑ ❑
■ ❑ ❑. ❑
❑ ❑ ❑
■ ❑ ❑ ❑
■ ❑ ❑ ❑
■ ❑ ❑ ❑
❑ ❑ ■ ❑
❑ El.
'� ❑
Comment: The dewatered sludge& from the wastewater treatment system (drying beds) and water
treatment -system are transported to the Alexander County Landfill for disposal.
Page# 7