Loading...
HomeMy WebLinkAboutNC0034967_Regional Office Historical File Pre 2018 (8)SOC PRIORITY PROJECT: No To: Permits and Engineering Unit Water Quality Section Attention: Charles Weaver Date: June 26, 2000 NPDES STAFF REPORT AND RECOMMENDATION County: Alexander MRO No. 99-144 Permit No. NCO034967 PART I - GENERAL INFORMATION 2. 3. 4. 5. 7. 8. Facility and Mailing Address: Physical Location: Carolina Glove Company, Inc. Post Office Box 999 Conover, N.C. 28613 140 Glove Mill Road Taylorsville, N.C. 28681 Date of Investigation: February 29, 2000 Report Prepared By: Michael L. Parker, Env. Engineer II Persons Contacted and Telephone Number: Ms. Rachel Mechimore; Tel# 704/632-2107 Directions to Site: The Company is located southwest of Taylorsville at the junction of the Lower Little River and SR 1115 (Glove Mill Road). Discharge Point(s). List for all discharge points: Latitude: 35°53'40" Longitude: 81 °12'50" Attach a U.S.G.S. map extract and indicate treatment facility site and discharge point on map. U.S.G.S.Quad No.: D 14 NW U.S.G.S. Name: Taylorsville Site size and expansion are consistent with application? Yes. Area is available for expansion, if necessary. Topography (relationship to flood plain included): Hilly, 5-10% slopes; The facility is not located within the 100 year flood plain. ��e Page Two 9. Location of nearest dwelling: None within 500 feet of the discharge location. 10. Receiving stream or affected surface waters: Lower Little River. a. Classification: C b. River Basin and Subbasin No.: Catawba; 03-08-32 C. Describe receiving stream features and pertinent downstream uses: The wastewater treatment plant discharges into the Lower Little River which has excellent flow at the point of discharge. The river has a rocky bottom, which provides for aeration and rapid assimilation of the effluent. The Town of Taylorsville (NC0026271) discharges approximately one mile downstream from Carolina Glove. Pertinent downstream uses are those typical for Class C water (secondary recreation, agriculture, etc.) PART II - DESCRIPTION OF DISCHARGE AND TREATMENT WORKS a. Volume of wastewater to be permitted: 0.015 MGD (Ultimate Design Capacity) b. What is the current permitted capacity of the wastewater treatment facility? 0.015 MGD" c. Actual treatment capacity of the current facility (current design capacity)? 0.015 MGD d. Date(s) and construction activities allowed by previous Authorizations to Construct issued in the previous two years: N/A e. Please provide a description of existing or substantially constructed wastewater treatment facilities: The existing treatment facility is a package type WWTP consisting of a comminutor, aeration basin, clarifier with sludge return, and effluent chlorinator. f. Please provide a description of proposed wastewater treatment facilities: N/A g. Possible toxic impacts to surface waters: Chlorine is added for disinfection. h. Pretreatment Program (POTWs only): N/A 2. Residuals handling and utilization/disposal scheme: The Company contracts Taylorsville Precast Company to remove and dispose of sludge as needed. Sludge is disposed at a Division of Solid Waste approved land application site (site Number 00104) on State Road 1614, Alexander County. Page Three 3. Treatment plant classification: Class II (no change from previous rating) 4. SIC Code(s): 3151 Wastewater Code(s): 02 Main Treatment Unit Code: 06007 PART III - OTHER PERTINENT INFORMATION 1. Is this facility being constructed with Construction Grant Funds or are any public monies involved (municipals only)? N/A 2. Special monitoring or limitations (including toxicity) requests: N/A 3. Important SOC, JOC or Compliance Schedule dates: (please indicate) N/A 4. Alternative Analysis Evaluation: Spray Irrigation: Insufficient area Connection to Regional Sewer System: None presently available. Subsurface: Insufficient area Other Disposal Options: N/A PART IV - EVALUATION AND RECOMMENDATIONS Carolina Glove Company, Inc., has requested renewal of the subject permit. There have been no changes in the Pemit or the WWT facility since the permit was last renewed.. Pending receipt of the WLA it is recommended that the permit be renewed as requested. Signature of Report Preparer D to hAdsr\dsr00\carg1ove.dsr 45� ev rmit renewal .- n sub'ect: NCO034967 - permit renewal Date: Mon, 08 Nov 1999 14:58:51 -0500 From: Charles Weaver <charles.weaver@ncmail.net> To: Glovel@Twave.net (This message is for Robert Abernethy.) Mr. Abernethy, the NPDES-Unit received the permit renewal application for Carolina Glove Company on October 27, 1999. Thanks for submitting this package in a timely fashion. I'm sorry to inform you that the NPDES Unit currently has several vacant positions, and has not been fully staffed for over a year. This staff shortage is delaying all of our permit renewals. Our remaining staff are currently reviewing Authorizations to Construct, speculative limit requests, major permit modifications and 201 plans ahead of permit renewals. This is necessary due to a variety of factors, including mandatory deadlines in the statutes which govern our program. If this staff shortage delays reissuance of NC0034967, the existing requirements in that permit will remain in effect until the permit is renewed (or other action is taken by the Division). We appreciate your patience and understanding as we operate with a depleted staff. If you have any questions about your permit (or the permit renewal process in general), simply reply to this e-mail. Sincerely, Charles H. Weaver, Jr. NPDES Unit 4W Mtn wit MMA*. ;kt I , IQZX NOV J15 1999 naislig.gf;-lg{: ��, f. , 0 � 3d 1 of 1 11/8/99 2:59 J" October 21, 1999 Mr. Charles H. Weaver, Jr. NCDENR/Water Quality/NPDES Unit 1617 Mail Service Center Raleigh, NC 27699-1617 I � !I 0 OCT CT 2 �. DENR - WATF QQUALITY J POINT 30URCE DR,�NCH Dear Mr. Weaver: This is a request for renewing Carolina Glove Company permit NCO034967 at our Alexander County plant which expires on June 30, 2000. There have been no changes since issuance of the present permit. Sincerely, ri Robert C. Aberneth President Carolina Glove Co. dla NPDES`PERNIITAPPLICATION, = SHORT FORM Cr For inanufacturing or commercial facilities with a discharge <1 MGD. (or WTRs) N. C. Department of Environment and Natural Resources Division of Water Quality / NPDES Unit 1617 Mail Service Center; Raleigh, NC 27699-1617 North Carolina NPDES Permit Number NC00 34967 Please print or type 1. Applicant and facility producing discharge A. Name CAROLINA GLOVE COMPANY = B. Mailing address of applicant: Street'addre'ss P':0. BOX 999 City CONOVER County CATAWBA State NC`::,,... Zip Code 28613 Telephone Number (-828 ) 464-1182 Fax Number ( 828 ) 464-1710 e-mail address Glovel@Twave.net C. Location of facility: Street 2675 H LEBOUN ljD (5/oye- 1W,,!/ 12o.40 City. TAYLORSVILLE- County''ALEXANDER ' State NC Zip Co_ de_ 28681 ' Telephone Number ( 828) 632-2107 2. Standard Industrial Classification (SIC) code(s): 3151 3. Number of employees: -90. • 4. Principal products) produced'` `'gloves= - Principal rawmatenal(s) consumed: fiber & leather 5. Principal process(es): cut &sew 6. Amount of principal product produced or raw material consumed (` st specific atnounts:co sumed and/or uriits'of-production)"', Product Produced or Raw Material Consumed Product Produced or Raw Material Consumed AVERAGE PEAK per Da per Month 13,500 DOZEN AVERAGE SAME ALL YEAR per Year . 162,000 DOZEN AVERAGE SAME ALL YEAR. 7. Check here if discharge occurs all year [ or Circle_ the months) in which discharge occurs: January February March April' May June July August September October November December Days per week discharge occurs 5 NOTE: If the facility has separate discharge points (outfalls) or multiple industrial processes, include a schematic diagram of wastewater flow at the facility. Page 1 of 2 Version -6-99 W, 0 NMES PERART APPLICATION =: SHORT FORM C For manufacturing or commercial facilities with a discharge <1 MGD'.(or WTPs) Types of wastewater discharged to surface waters only (check as applicable). Discharge per operating day Flow.. Volume treated before discharging GALLONS PER OPERATING DAY PERCENT Sanitary - daily average Cooling water, etc. - daily average .0 Process. water.- daily.average Maximum per operating day for. total discharge (all types) 2000 9. If any of the types of wastewater identified in item 8 (either treated or untreated) are discharged to places other than surface waters, record the amounts) discharged below: A. Municipal sewer system gpd B. Underground well gpd C. Septic tank gpd D. Evaporation lagoon or pond gpd E.. ..: Other,.specify gpd 10. Number of separate discharge•points'�•`-•—" 1-1. Name of receiving stream(s):'--',�LOWER LIfTL:E' 12.. - Does your discharge coritain or is -it possible for your discharge to contain one or more of the following substances added, as ya result, of your operations, activities, or processes?.: Circle, all,that apply,, ,_. : aluminum ammonia beryllium :'cadmium chromium, chlorine .(residual),,.,,. - copper. cyanide lead mercury nickel oil and grease.,,,, , phenols selenium zinc None of the;above tt�?! !ilFais.'�'if'•' ':..,:;'i"tii ;l i.)::= .,.. ... . 1 certify that I am familiar with the Information. contained ,in the. application and that to.the best of my knowledge "bbeliefsuch infgr" at!on`is true,' corripletean . accurafe ::: ROBERT C. ABERNE PRESIDENT Printed name of Person Signing Title I D /0.2 19)9 Signature of.Applicant . North Carolina General Statute 143-215.6 (b)(2) provides that: Any person who knowingly makes any false statement representation, -,or certification in any application, record, report, plan, or other document files or required to be maintained under Article 21 or regulations of the Environmental -Management Commission implementing that -Article, or who falsifies,.,tampers-with, or.knowingly renders inaccurate any recording or monitoring device or method-• required to be operated or maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, shall be guilty of a misdemeanor punishable by a fine not to exceed $10,000, or by imprisonment not to exceed six months, or by both. (18 U.S.C. Section 1001 provides a punishment by a fine of not more than $10,000 or imprisonment not more than 5 years, or both, fora similar offense.) Page 2 of 2 Version —6-99 (+AROLI NAj LOVE ,U-O. M A N U:df-..VCF,Tv'U Z R E R S O F Phone 464-1132 ,Ceather, G'amtofl Amid, Yersery Ic Coated gloves Pas, office Area Code828 CONOVER, NORTH CAROLINA 28613 Box999 October 21, 1999 Mr. Charles H. Weaver, Jr. NCDENR/Water Quality/NPDES Unit 1617 Mail Service Center Raleigh, NC 27699-1617 Dear Mr. Weaver: Subject: Sludge Management Taylorsville Precast, a septic hauler, disposes of the sludge at Carolina Glove Company in Alexander County. Their phone number is (828)632-4608. They pump sludge two to three times a year as needed and pump sludge from the clarifier, leaving a small amount of seed sludge to maintain the treatment process. It is then hauled to their disposal site. Sincerely, I Robert C. Abernethy `✓✓ President Carolina Glove Co. dla NPDES Permit NCO034967 CAROLINA GLOVE COMPANY ALEXANDER County The following items are REgUIRED for all renewal packages: A cover letter requesting renewal of the permit and documenting any changes at the facility since issuance of the last permit. Submit one signed original and two copies. FY The completed application form (copy attached), signed by the permittee or an Authorized Representative. Submit one signed original and two copies. ❑ If an Authorized Representative (see Part II.B.1 Lb of the existing NPDES permit) prepares the renewal package, written documentation must be provided showing the authority —/ delegated to the Authorized Representative. l� A narrative description of the sludge management -plan for the facility. Describe how sludge (or other solids) generated during wastewater treatment are handled and disposed. If your facility has no such plan (or the permitted facility does not generate any solids), explain this in wilting. Submit one signed original and two copies. The following items must be submitted ONLY by Industrial facilities discharging process wastewater: ❑ Submit the last 3 years' production data for the facility. Use units consistent with those required for reporting to EPA. ❑ Industrial facilities classified as Primary Industries (see Appendix A to Title 40 of the Code of Federal Regulations, Part 122) must submit a Priority Pollutant Analysis (PPA) in accordance with 40 CFR Part 122.21. If the PPA is not completed within one week of January 2, 2000, submit the application package without the PPA. Submit the PPA as soon as possible after January 2, 2000. The above requirements do NOT apply to municipal or non -industrial facilities. PLEASE NOTE: Due to a change in fees effective January 1, 1999, there is no renewal fee required with your application package. Send the completed renewal package to: Mr. Charles H. Weaver, Jr. NC DENR / Water Quality / NPDES Unit 1617 Mail Service Center Raleigh, NC 27699-1617