Loading...
HomeMy WebLinkAboutNCG550201_Regional Office Historical File Pre 2018 (6)William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources 1W,0t QG i June 24, 2008 Mr. Robert Bollinger 291 Hughes Boulevard North Hickory, NC 28601 Coleen H. Sullins, Director Division of Water Quality Subject: Bollinger Single Family Residence COC No. NCG550201 Compliance Evaluation Inspection Alexander County Dear Mr. Bollinger: Enclosed is a copy of the Compliance Evaluation Inspection (CEI) for the inspection conducted at the subject facility on June 17, 2008, by Ms. Barbara Sifford with this Office. Thank you for your assistance and cooperation during the inspection. The system at the time of the inspection did not have a discharge therefore no analytical had been performed. The chlorinator and discharge box were dry and there is no presence of surface discharge. Should this system ever discharge samples should be collected and. analyzed. If the system fails and causes any surface water impacts or discharges to the ground surface the system will have to be repaired to original design specifications. The enclosed reports should be self-explanatory. If you have any questions, comments, or need assistance with understanding any aspect of your permit or this report, please do not hesitate to contact me at (704) 663- 1699,ext 2196. Sincerely, Barbara R. Sifford Technical Support Surface Water Protection Section Division of Water Quality Enclosures Cc: MRO SFR- Bollinger One N iura!!y Central Files North Carolina Division of Water Quality Internet: www.ncwateraualitv.org Mooresville Regional Office 610 East Center Avenue, Suite 301 Mooresville NC 28115 Phone (704) 663-1699 Fax (704)663-6040 Customer Service 1-877-623-6748 United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 INI 2 I5I 31 NCG550201 I11 121 08/06/17 117 18ICI 19ISI 20I Remarks 211 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I i I i l l 16 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA —------ -------Reserved------------ 67I 169 70I 11 711 I 721 NJ 73 LLJ 74 751 I I I I I I 180 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 291 Hughes Boulevard North 06:00 PM 08/06/17 07/08/01 Exit Time/Date Permit Expiration Date 291 Hughes Blvd N Hickory NC 28601 07:00 PM 08/06/17 12/07/31 Name(s) of Onsite Representative(s)/ritles(s)/Phone and Fax Number(s) Other Facility Data Name, Address of Responsible Official[Title/Phone and Fax Number Robert Bollinger,291 Hughes Blvd N Hickory NC 28601/// ContactedNo Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Operations & Maintenance 0 Facility Site Review Effluent/Receiving Waters Section D: Summary of Find in /Comments Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Barbara Sifford MRO WQ//704-663-1699 Ext.2196/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page # 1 NPDES W3, I NCG550201 I11 yr/mo/day Inspection Type 12I 08/06/17 I17 18ICI (cont.) 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) No analytical has been performed since no flow is appartent from the system. Inspection from this office in 1992 indicated no flow at that time. Meter readings from the City of Hickory watermeter indicate about 3000 gallons per month are used at the residence. The wastewater has to be leaking underground either from the tank or the sand filter. No discharge to the lake or to the surface of the ground is apparent. No environmental impacts can be detected, should this ever occur the system will have to be repaired to design specifications. Page # 2 Permit: NCG550201 Inspection Date: 06/17/2008 Owner - Facility: 291 Hughes Boulevard North Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? ■ Cl n n Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge n ■ 0 n Judge, and other that are applicable? Comment: No analysis performed no effluent discharge ever apparent. Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new application? ■ n n n Is the facility as described in the permit? ■ n n n # Are there any special conditions for the permit? n ■ n n Is access to the plant site restricted to the general public? ❑ ■ ❑ ❑ Is the inspector granted access to all areas for inspection? ■ n n n Comment: Permit renewed last year, chlorine tablets in chlorinator box no dampnees apparent. Water meter reading from Hickory indicates monthly usage from 2500 to 3000 gallons. Septic tank has been pumped several months ago. Sand Filters (Low rate) Yes No NA NE (If pumps are used) Is an audible and visible alarm Present and operational? n ■ n n Is the distribution box level and watertight? n n Cl ■ Is sand filter free of ponding? ■ n ❑ n Is the sand filter effluent re -circulated at a valid ratio? n ■ n n # Is the sand filter surface free of algae or excessive vegetation? n n n ■ # Is the sand filter effluent re -circulated at a valid ratio? (Approximately 3 to 1) n ❑ ■ n Comment: Sand filter is adjacent to septic tank but does not appear to have any ponding. Soil is placed over the filter bed. Disinfection -Tablet Yes No NA NE Are tablet chlorinators operational? ■ n n n Are the tablets the proper size and type? ■ n n n Number of tubes in use? 2 Is the level of chlorine residual acceptable? ❑ n ■ n Is the contact chamber free of growth, or sludge buildup? ■ ❑ 11 ❑ Is there chlorine residual prior to de -chlorination? n n ■ o Comment: No flow in chlorinator box. Dry tablet powder. Page # 3