Loading...
HomeMy WebLinkAboutWQ0041880_Application (FTSE)_20201020Permit Number WQ0041880 Program Category Non -discharge Permit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer dean.hunkele Coastal SWRule Permitted Flow 15,400 Facility Central Files: APS _ SWP 10/16/2020 Permit Tracking Slip Status Project Type In review Major modification Version Permit Classification B Individual Permit Contact Affiliation Facility Name Major/Minor Region Saxon Place Apartments Private Sewer Minor Wilmington Location Address County New Hanover Facility Contact Affiliation Owner Owner Name Owner Type Saxon Place LLC Non -Government Owner Affiliation Christopher Buffalino 2918 A Martinsville Rd Dates/Events Greensboro NC 27408 Scheduled Orig Issue App Received Draft Initiated Issuance 8/18/2020 10/12/2020 Regulated Activities Apartment complex Restaurant Wastewater colleclipn Public Notice Issue Effective Expiration TSs&'O� (d--'1rj Reauested /Received Events Additional information requested Additional information received Outfall RECEIVED NOMS & TUNSTALL CONSULTING ENGINEERS P.C. 2602 Iron Gate Dr., Suite 102 Wilmington, NC 28412 (910) 343-9653 (910) 343-9604 Fax John S. Tunstall, P.E. T. Jason Clark, P.E. October 6, 2020 Dean Hunkele NCDEQ - Water Quality Division Wilmington Regional Office 127 Cardinal Drive Extension Wilmington, NC 28405 OCT 12 2020 1429 dsH\river Road .3shN*UMN RO (910) 287-5900 (910) 287-5902 Fax J. Phillip Norris, P.E. Joseph K. Bland, P.E. '17iomas J. Scheetz, E.I. Re: Gravity Sewer Extension Fast -Track Permit Application - Modification Project: Saxon Place Apartments Private Sewer Permit No. WQ0041880 Dear Mr. Hunkele, The permit is being modified to reflect the changes due to the total length of the sewer having increased more than 10% due to field conflicts, and an interference manhole that is deemed a "high priority" line. Enclosed please find a check in the amount of $480.00 (Norris Check No. 1700) for the processing fee, copy of Permit WQ0041880 issued August 18, 2020, Fast Track Sewer Extension Application with attachment, Sewer Narrative, one (1) 81/2x 11 color USGS Topographic Maps, and as-builts (ledger size). Please review this information for approval and contact us with any questions or comments you may have. Thank you for your assistance on this project. Sincerely, NORRIS & TUNSTALL CONSULTING ENGINEERS, P.C. J. P illip rris, P. J P Ittw 19 4 10-06-20 state fast track swr Itr (private) Enclosures cc: Chris Buffalino NCBELS License C-3641 DWR Division of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: (to be completed by DWR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: 1. Applicant's name: Saxon Place LLC (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ® Corporation ❑ General Partnership ❑ Federal ❑ State/County ❑ Municipal 3. Signature authority's name: Chris Buffalino per 15A NCAC 02T .0106(b) Title: Manager 4. Applicant's mailing address: 439 Whitebridge Road City: Hampstead State: NC Zip: 28443- 5. Applicant's contact information: Phone number: 910) 795-8674 Email Address: chrisbuffalino@gmail.com II. PROJECT INFORMATION: ❑ Privately -Owned Public Utility ❑ Other 1. Project name: Saxon Place Apartments - Private Sewer 2. Application/Project status: ❑ Proposed (New Permit) ® Existing Permit/Project If a modification, provide the existing permit number: W00041880 and issued date: 08-18-2020 If new construction but part of a master plan, provide the existing permit number: W000 3. County where project is located: New Hanover 4. Approximate Coordinates (Decimal Degrees): Latitude: 34.2379' Longitude:-77.8999' 5. Parcel ID (if applicable): R04917-004-017-000 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: J. Phillip Norris, P.E. License Number: 11966 Firm: Norris & Tunstall Consulting Engineers, P.C. Mailing address: 1429 Ash -Little River Road City: Ash State: NC Zip: 28420- Phone number: (910) 287-5900 Email Address: pnorris@ntengineers.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: James A. Loughlin (Northside WWTP) Permit Number: 0023965 Owner Name: Cape Fear Public Utility Authority V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): W00041879 Downstream (Receiving) Sewer Size: 8 inch System Wide Collection System Permit Number(s) (if applicable): WQCS Owner Name(s): Cape Fear Public Utility Authori y FORM: ETA 04-16 Page 1 of 5 Vl. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑No ®N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached? ❑ Yes ❑No ®N/A 3. If the Applicant is a Home/Property Owners' Association, has an Operational Agreement (FORM: HOA) been attached? ❑ Yes ❑No ®N/A 4. Origin of wastewater: (check all that apply): ❑ Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ® Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motels ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool /Clubhouse ® Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater: 100 % Domestic/Commercial % Commercial % Industrial (See 15A NCAC 02T .0103(20)) " Is there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Hasa flow reduction been approved under 15A NCAC 02T .01 W ? ❑ Yes ❑ No ➢ If yes, provide a copy of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see 021.0114(fl) Daily Design Flow a,b No. of Units Flow 3 Bedroom Apts. 360 gal/Unit 12 4,320 GPD 2 Bedroom Apts. 240 gal/Unit 12 2,880 GPD 1 Bedroom Apts. 240 gal/Unit 30 7,200 GPD 1,400 SF Restaurant with 25 seats 40 gal/Seat 25 1,000 GPD gal/ GPD gal/ GPD Total 15,400 GPD a See 15A NCAC 02T .0114(b), (d), (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .01 14(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 15400 GPD (per 15A NCAC 02T .0114) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T.0305 & MDC (Gravity Sewers): l . Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8" 216.94 PVC 8" 20 DIP s Increasa zko a1.c H LF VC arA a;OLF IJ"o basa o r\ ➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) COcxdi�i0(�S ➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: - ° 3. Design flow of the pump station: millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): gallons per minute at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B).' ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T.0305(f)): 1. Does the project comply with all separations found in 15A NCAC 02T.0305(f) & (s) ➢ 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer systems: ® Yes ❑ No Setback Parameter* Separation Required Storm sewers and other utilities not listed below vertical 24 inches Water mains vertical -water over sewer including in benched trenches 18 inches Water mains horizontal 10 feet Reclaimed water lines vertical - reclaimed over sewer 18 inches Reclaimed water lines horizontal - reclaimed over sewer 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class I or Class II impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water or tide elevation and wetlands see item IX.2 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade vertical 36 inches ➢ 15A NCAC 02T.0305(e) contains alternatives where separations in 02T.0305(f) cannot be achieved. ➢ **Stream classifications can be identified using the Division's NC Surface Water Classifications webnaee ➢ If noncompliance with 02T.0305(fl or (e). see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ® Yes ❑ No ❑ N/A ➢ See the Division's draft separation requirements for situations where separation cannot be meet ➢ No variance is required if the alternative design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ® Yes ❑ No ❑ N/A ➢ This would include Trout Buffered Streams per 15A NCAC 2B.0202 4. Does the project require coverage/authorization under a 404 Nationwide or ® Yes [:]No individual permits or 401 Water Quality Certifications? ➢ Information can be obtained from the 401 & Buffer Permitting Branch 5. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes ❑ No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ® Yes ❑ No ❑ N/A ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains (latest version), and the Gravi1y Sewer Minimum Design Criteria latest versi"on�as applicable? ® Yes ❑ No NCTTE Cec`4l iegtt On For 10C 4ZO-ro f Net If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Anolication and supporting documents. Professional Engineer's Certcatioon: �K.///6I, l%0 M/ry-V7 `J attest that this application for (Profe onal Engin/ee,,'pp�r�'s nam from Ap ication It II[.I.)f� Q iC C7 /l Ail GL �t� r �7/4 - ✓I/� Le �JLH/ w has been reviewed by me and is accur222ttte, complete and consistent wrth the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE - In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and dater 3. Applicant's Certification per 155AA NCAC 02T .0106(b): I, C✓l5 1el a name & fitle from Applicatiim Item 1.3.) O'. FIO 0� Z011 , o, 'N/LLIP that this application for has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE - In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: 9�4� —, Date: i'� 1✓c�`��G b FORM: FTA 04-16 Page 5 of 5 N LnLi-) O Lc) r�00 Lo Oi 2 O N (n cf) 0 z � 1� � Z We %NLEI --- ............._—.---------- -- N__. SSMN EXST S TOP 35.48 INV. 28.98 A LiJ 2 Z � W 0 (n W CO :2 W o O O U) i- m iNISH GRADE III III 20 LF DIP III �l�Of1 Pe�aw Lj0 5 EC�10', ON MANHOLE 52 �F 8 SS 1.80% T I 110.20 LF 8"SS @ 0.43% N PRIVATE SECTION EX. 8" WATER MAIN' 0+50 1+00 1 +50 40.10 U @ 0.45i SEWER NARRATIVE SAXON PLACE 3525 Lancelot Lane Wilmington, North Carolina For Saxon Place, LLC 439 Whitebridge Road Hampstead, NC 28443 (910)795-8674 66 ,�o, etd�tlhl�� Prepared by: NORRIS & TUNSTALL CONSULTING ENGINEERS, P.C. 1429- Ash — Little River Road Ash, North Carolina 28420 (910) 287-5900 (910) 287-5902 (Fax) License # C-3641 N&T Project No. 19004 Id/_\:U_%IIT" SAXON PLACE PUBLIC and PRIVATE SEWER SEWER SYSTEM: This public and private gravity system was designed to service the proposed apartment complex known as Saxon Place, located at 3525 Lancelot Lane in Wilmington, NC. A total of 37 LF (Public) of 8-inch sewer line, 265 LF (Private) of 6-inch sewer line and 196 LF of 8-inch sewer line was permitted to complete the system. During construction there were numerous conflicts with existing underground utilities that required field changes to be done for the sewer line to function. The public system WQ0041879 was increased in total length of 8 inch gravity sewer main to 45.52 feet. No other changes occurred. The private system WQ0041880 was changed to eliminate all of the 6 inch line and change the 8 inch length to 216.94 feet of 8 inch PVC and 20 feet of 8 inch DIP. An interference manhole was also installed due to a conflict with a stormdrain. This will be deemed "high priority' and is shown on the as -built drawings.