HomeMy WebLinkAboutSW5200602_Supplement-EZ Form_20201020NUMBER AND TYPE OF SC �K.......... ........� . .�.mm. . ...�..
Ms:
11
tion yste 0
of .� - w
12 ..
Pioretention Cell I ... _
3
Wet Pond —-- ----- ------ ._.m....m....., ........9
14
Stormwater Wetland
0
15 .
.. ._..... _ ........... .----.__,,,......
_
16
Sand Filter
2
17
Rainwater Harvestin RWH
mmm. _ .mm s. G... .... ... u. _ _ ...-.-.
......... ....... .. 0
18
Green Roof
0
19
Level Spreader -Filter Stnp (LS FSJ
20
Disconnected Impervious Surface (DIS)21
0
...
reatment Swale
0
??,,,I
Dry Pond .................. n.. ........... .. �� _
0
...........
_. 23
StormFilter
�,��.,......... .�.�........... ..............u_.... ....-
0
24
Silva Cell
0
Bilterrta r .. — — ........- ^. .....
.. .....
26
0
FORMS LOADED
w., .,„ ......... ..._.
DESIGNER CERTIFICATION
o....
27
Name and Title
JeffRice, PE
28
Organization
Stantec
2
Street address
a 2127 Arysley Town Blvd Suite 300
..
3.0
City State Zip:
Charlotte NC 28273
31
Phone numbers .): ................. -----
704 329 0900
32
Email:
jeff.rice@stantec,com
Certification Statement:
I certify, under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or
supervision; that the information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete; and
that the engineering plans, specifications, operation and maintenance agreements and other supporting information are consistent
with the information provided here.
���gt111thdl",e,,"
.. J
to
w�
fg9��. mm
Date
DRAINAGE AREAS
1Is this a high density project?Yes
2 If so, number of drainage areas/SCMs2
Is all/part of this project subject to previous rule
3versions?No
FORMS LOADED
Entire Site12
DRAINAGE AREA INFORMATION
4Type of SCM Sandfilter/LS-FSSandfilter/LS-FS
5Total BUA in project (sq ft)612789 sf144687 sf40758 sf
New BUA on subdivided lots (subject to permitting)
6(sq ft)
New BUA outside of subdivided lots (subject to
7permitting) (sf)185445 sf144687 sf40758 sf
8Offsite - total area (sq ft)
9Offsite BUA (sq ft)
10Breakdown of new BUA outside subdivided lots:
-Parking (sq ft)
-Sidewalk (sq ft)1448 sf1448 sf
-Roof (sq ft)9504 sf2163 sf7341 sf
-Roadway (sq ft)
-Future (sq ft)
-Other, please specify in the comment box
below (sq ft) 174493 sf141076 sf33417 sf
New infiltrating permeable pavement on subdivided
11lots (sq ft)
New infiltrating permeable pavement outside of
12subdivided lots (sq ft)
Exisitng BUA that will remain (not subject to
13permitting) (sq ft)427334 sf
14Existing BUA that is already permitted (sq ft)
15Existing BUA that will be removed (sq ft)3289 sf
16Percent BUA47%57%44%
17Design storm (inches)1 in1 in
18Design volume of SCM (cu ft)8935 cf2559 cf
Calculation method for design volumesimple methodsimple method
19
ADDITIONAL INFORMATION
Please use this space to provide any additional information about the
20drainage area(s):
gravel and concrete pads..
SAND FILTER
Drainage area number12
1
Design volume of SCM (cu ft)8935 sf2559 sf
2
GENERAL MDC FROM 02H .1050
Is the SCM sized to treat the SW from all surfaces at build-out?YesYes
3
Is the SCM located away from contaminated soils?YesYes
4
What are the side slopes of the SCM (H:V)?3:13:1
5
Does the SCM have retaining walls, gabion walls or other engineered
side slopes? NoNo
6
Are the inlets, outlets, and receiving stream protected from erosion (10-
year storm)?YesYes
7
Is there an overflow or bypass for inflow volume in excess of the design
volume?YesYes
8
What is the method for dewatering the SCM for maintenance?Drawdown OrificeDrawdown Orifice
9
If applicable, will the SCM be cleaned out after construction?YesYes
10
Does the maintenance access comply with General MDC (8)?YesYes
11
Does the drainage easement comply with General MDC (9)?YesYes
12
If the SCM is on a single family lot, does (will?) the plat comply with
General MDC (10)?NoNo
13
Is there an O&M Agreement that complies with General MDC (11)?YesYes
14
Is there an O&M Plan that complies with General MDC (12)?YesYes
15
Does the SCM follow the device specific MDC?YesYes
16
Was the SCM designed by an NC licensed professional?YesYes
17
SAND FILTER MDC FROM 02H .1056
SHWT elevation (fmsl)< 433.5< 425.5
18
Type of sand filter (open or closed)OpenOpen
19
If closed, will the filter will be pre-cast or pour-in-place?
20
If closed, top of grate elevation (fmsl)
21
Is this sand filter designed to attenuate peak flows? YesYes
22
Sediment Chamber
Volume that can be retained in the sediment chamber (cubic feet)10267 cf6713 cf
23
Will there be a permanent pool in the sediment chamber?NoNo
24
Bottom of the sediment chamber (fmsl)442.00446.00
25
5337 sf3685 sf
Area of the sediment chamber (square feet)
26
Physical depth of the sediment chamber (inches)24 in24 in
27
Ponding depth in the sediment chamber, above any permanent pool
(inches)24 in24 in
28
Elevation of top of weir between chambers (fmsl)444448
29
Sand Chamber
10267 cf6713 cf
Volume that can be retained in the sand chamber (cubic feet)
30
Bottom of the sand chamber (fmsl)439.50443.50
31
4500 sf1500 sf
Area of the sand chamber (square feet)
32
Physical depth of the sand chamber (inches)54 in54 in
33
Ponding depth in the sand chamber, above any permanent pool
(inches)24 in24 in
34
Elevation of the bypass device (fmsl)444448
35
Type of bypass deviceConc Box RiserConc Box Riser
36
Mechanism for distributing flow over the sand surfaceRiprap WeirsRiprap Weirs
37
Sand specification for sand chamberASTM C-33ASTM C-33
38
Depth above underdrain pipe (inches)18 in18 in
39
Will the media be maintained to drain at least two inches per hour at the
sand surface?YesYes
40
Is at least one clean-out pipe provided at the low point of each
underdrain line?YesYes
41
Will clean-out pipes be capped? YesYes
42
ADDITIONAL INFORMATION
Please use this space to provide any additional information about the
Sand Filter(s):
43
Sand Filter21:20 PM 10/19/2020
LEVEL SPREADER - FILTER STRIP (LS-FS)
Drainage area number12
1
Design volume of SCM (cu ft)8935 cf2559 cf
2
GENERAL MDC FROM 02H .1050
Is the SCM sized to treat the SW from all surfaces at build-out?YesYes
3
Is the SCM located away from contaminated soils?YesYes
4
What are the side slopes of the SCM (H:V)?20:120:1
5
Does the SCM have retaining walls, gabion walls or other engineered
side slopes? NoNo
6
Are the inlets, outlets, and receiving stream protected from erosion
(10-year storm)?YesYes
7
Is there an overflow or bypass for inflow volume in excess of the
design volume?YesYes
8
What is the method for dewatering the SCM for maintenance?OtherOther
9
If applicable, will the SCM be cleaned out after construction?YesYes
10
Does the maintenance access comply with General MDC (8)?YesYes
11
Does the drainage easement comply with General MDC (9)?YesYes
12
If the SCM is on a single family lot, does (will?) the plat comply with
General MDC (10)?NoNo
13
Is there an O&M Agreement that complies with General MDC (11)?YesYes
14
Is there an O&M Plan that complies with General MDC (12)?YesYes
15
Does the SCM follow the device specific MDC?YesYes
16
Was the SCM designed by an NC licensed professional?YesYes
17
LS-FS MDC FROM 02H .1059
Length of level spreader (feet)40 ft20 ft
18
Does the LS-FS receive flow from the drainage area or another
SCM?YesYes
19
Flow rate to LS-FS during design storm (cfs)3 cfs1 cfs
20
Is a bypass device provided?NoNo
21
If yes, what is the bypass device?
22
Is this LS-FS designed to receive flow from the drainage area during
the 10-year storm?
23
Has a blind swale been provided?YesYesYes
24
Does the blind swale provide for uniform overtopping of the level
spreader?YesYes
25
What material will be used for the level spreader?concreteconcrete
26
Will the construction tolerance be < 0.25 inch along the level
spreader length?YesYes
27
Will the level spreader be straight or convex in plan view?YesYes
28
Height of the drop from the level spreader to the transition zone
(inches)3 in3 in
29
Width of the transition zone (inches)36 in36 in
30
Protection for the transition zoneAggregateAggregate
31
Width of the filter strip (feet)30 ft30 ft
32
Is the filter strip free of draws and channels?YesYes
33
Has this been verified in the field?YesYes
34
Slope of the filter strip (%)5%5%
35
Is this slope uniform across the entire filter strip?YesYes
36
Will the first 12" of soil be adjusted if needed to promote plant
growth?NoNo
37
Will the filter strip and side slopes be planted with non-clumping,
deep-rooted sod?YesYes
38
Species of sod that will be usedcommon bermudacommon bermuda
39
Will soil be temporarily stabilized until permanent vegetation is
established?YesYes
40
ADDITIONAL INFORMATION
Please use this space to provide any additional information about the
level spreader-filter strip(s):
41
LS-FS31:20 PM 10/19/2020