Loading...
HomeMy WebLinkAboutWI0300045_Compliance Evaluation Inspection_20200717 (2)ROY COOPER Governor MICHAEL S. REGAN Secretary S. DANIEL SMITH Director NORTH CAROLINA Environmental Quality July 17, 2020 William White, Director of Facilities (via email) Catawba College 2300 W. Inns St. Salisbury, NC 28144 Subject: Catawba College Geothermal Well System Compliance Inspection Permit No. WI0300045 Rowan County Dear Mr. White: On July 15, 2020, a staff member of the Mooresville Regional Office (MRO) performed a site visit of the Geothermal Heating/Cooling Water Return Well Loops at Catawba College under permit WI0300045. The MRO would like to thank you and your staff for your assistance during this site visit. According to information provided by your office, several of the heat exchange units in the well loops have been replaced due to normal wear and tear. During the site visit, we selected wells for groundwater sampling, and the selected wells were reviewed. Please proceed with the sample collection and forward the results to us when complete. The attached report should be self-explanatory; however, should you have any questions, feel free to contact our office by phone at 704-235-2198 or by email at edward.watsongncdenr.gov. Sincerel DocuSigned by A#4" N Nuft F161 F669AMUA3... Andrew H. Pitner, Assistant Regional Supervisor Water Quality Regional Operations Section Mooresville Regional Office Division of Water Resources, NCDEQ Attachment: Inspection Report CC: Laserfiche file Mike Rogers, DWR UIC Program (via LaserFche) D E Qbi�� North Carolina Department of Environmental Quality I Division of Water Resources Mooresville Regional Office 1 610 East Center Avenue, Suite 301 1 Mooresville, North Carolina 28115 vOry rN Cx:40:.itiA � 0.. a to E".w^^�"��a°:r� /� 704.663.1699 Compliance Inspection Report Permit: W10300045 Effective: 08/21/15 Expiration: 07/31/20 Owner: Catawba College SOC: Effective: Expiration: Facility: Catawba College County: Rowan Catawba College Region: Mooresville 2300 W Innes St Salisbury NC 28144 Contact Person: William T White Title: Phone: 704-645-4502 Directions to Facility: Catawba College is located approximately 3 miles north of Salisbury, North Carolina on West Innes Street. The Administration Building (Hedrick Building) located at 2300 W. Innes Street is located on the left. System Classifications: Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Date: 07/15/2020 Entry Time 09:OOAM Exit Time: 11:30AM Primary Inspector: Edward Watson Phone: Secondary Inspector(s): Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Injection Heating/Cooling Water Return Well Facility Status: 0 Compliant ❑ Not Compliant Question Areas: Wells 0 System Operations (See attachment summary) Page 1 of 3 Permit: W10300045 Owner - Facility: Catawba College Inspection Date: 07/15/2020 Inspection Type: Compliance Evaluation Reason for Visit: Routine Inspection Summary: On July 15, 2020, MRO staff performed a site visit to Catawba College under permit W10300045 Geothermal Return well network. During the site visit, wells were inspected for the three existing geothermal loops. System sampling requirements were discussed with Catawba College staff. A well pairing of one supply well and one return well was selected for each loop. A total of three sample pairs will be collected for the Geothermal system a Catawba College. Well,#3 is currently being repaired. However, the repair is expected to be completed by 7/17/2020 so the well can be sampled. Wells 3 & 4 will be sampled for the New Loop, Wells 13 & 16 will be sampled for Woodson Loop, and wells 9 & 10 will be the sample pair for the Abernathy Residence Loop. Heat exchange units have been recently changed for Salisbury -Rowan Dorm, and Pine Knot dorm in the new loop, Woodson dorm and Stanback dorm in the Woodson well -loop. All of these heat exchange units were replaced within the last three years. Catawba College has decided to hire a consultant to perform the well sampling. MRO staff reminded Catawba College staff of the importance of sterilizing the well ports before the collection of the Coliform samples. The hired consultant will also determine the laboratory that will perform the analysis for the GW samples. Page 2 of 3 Permit: W10300045 Owner - Facility: Catawba College Inspection Date: 07/15/2020 Inspection Type: Compliance Evaluation Reason for Visit: Routine System Operation Is same well used as source well and injection well? Is injection well capable of assimilating injected fluid? Injection flow rate at time of inspection (gpm) Has system owner/operator noticed any abnormalities (turbidity, air in system, poor heating/cooling, etc) in system operation? Comment on system operation Is system operation and construction consistent with that described in application? Describe inconsistencies between application and observed operation/construction MRO is not aware of the existance of any inconsistancies. Yes No NA NE ❑■❑❑ ❑❑■❑ ❑■❑❑ ❑ ❑ ❑ ■❑❑❑ Comment: The system is composed of 16 wells. Six supply wells and ten return wells that compose three separate geothermal loops. The loops have multiple heat exchange units. The wells were selected are one supply well and one return well per loop. The wells were identified as part of the site visit. Well # 3 is out of service temporaliv to replace drop pipe. This well is expected to be return to service by 7/17/2020. Page 3 of 3