Loading...
HomeMy WebLinkAboutWQ0016376_Final Permit_20201020ROY COOPER Governor MICHAEL S. REGAN Secretary S. DANI£L SMITH Director JOSEPH P. VILLARI — OWNER S & J VILLARI LIVESTOCK LLC 892 PENNY BRANCH ROAD WARSAW, NORTH CAROLINA 28398 Dear Mr. Villari: NORTH CAROLINA Environmental Quality October 20, 2020 Subject: Permit No. WQ0016376 S & J Villari Livestock WWTF Wastewater Irrigation System Duplin County In accordance with your permit minor modification request received April 22, 2020, and subsequent additional information received July 6, 2020 and September 8, 2020, we are forwarding herewith Permit No. WQ0016376 dated October 20, 2020, to S & J Villari Livestock LLC for the construction and operation of the permitted modifications, as well as the continued operation of the existing wastewater treatment and irrigation facilities. The following modifications to the subject permit are as follows: Adjusted the acreages for Zones 1 and 2; adding a pump station with a 240 gallon per minute (GPM) pump and approximately 320 linear feet 4-inch force main. This permit shall be effective from the date of issuance through November 30, 2025, shall void Permit No. WQ0016376 issued January 3, 2020, and shall be subject to the conditions and limitations therein. The Permittee shall submit a renewal application no later than June 3, 2025. Please pay attention to the monitoring requirements listed Attachments A, B, and C for they may differ from the previous permit issuance. Failure to establish an adequate system for collecting and maintaining the required operational information shall result in future compliance problems. The following permit conditions are new since the last permit issuance dated January 3, 2020: ➢ Condition I.I. — The condition requires an Engineering Certification be submitted upon completion of construction and prior to operation of the permitted modifications. ➢ Condition L2 — The condition requires the Permittee to notify the Wilmington Regional Office prior to the initial operation of the constructed facilities. ➢ Condition L3. — The condition requires a Final Operation and Maintenance Plan be submitted. D Q �� North Carolina Department of Environmental Quality I Division of Water Resources 512 North Salisbury Street 1 1617 Mail Service Center I Raleigh, North Carolina 27699-1617 NOR fH CA�in!.INA 1­4'torenwm—ta�a"1 919,707.9000 Mr. Joseph P. Villari October 20, 2020 Page 2 of 2 If any parts, requirements, or limitations contained in this permit are unacceptable, the Permittee has the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request shall be in the form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings at 6714 Mail Service Center, Raleigh, NC 27699-6714. Otherwise, this permit shall be final and binding. One set of approved plans and specifications is being forwarded to you. If you need additional information concerning this permit, please contact Vivien Zhong at (919) 707-3627 or vivien.zhongkncdenr.gov. Sincerely, 7L4( �-2) S. Daniel Smith, Director Division of Water Resources cc: Duplin County Health Department (Electronic Copy) Wilmington Regional Office, Water Quality Regional Operations Section (Electronic Copy) Jeff Cappadona, PE — Cavanaugh & Associates, P.A. (Electronic Copy) Laserfiche File (Electronic Copy) Digital Permit Archive (Electronic Copy) NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENTAL QUALITY RALEIGH WASTEWATER IRRIGATION SYSTEM PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO S & J Villari Livestock LLC Duplin County FOR THE operation of a 100,260 gallon per day (GPD) wastewater treatment and irrigation facility consisting of the: construction and operation of. a pump station with a 240 gallon per minute (GPM) pump; approximately 320 linear feet (LF) of 4-inch force main; and all associated piping, valves, controls, and appurtenances; and the continued operation of. a T-R solids separator; a curbed 20-feet by 24-feet solids collection area with leachate collection and daily solids rendering collection; a 10,000 gallon storage tank; a 2,000 gallon pump tank with dual solids handling pumps; a 3.65 million gallon (MG) synthetically -lined facultative lagoon with a curtain baffle separating it into two zones, and served by two 10 horsepower (hp) floating aerators; a 1.88 MG above -ground stainless steel storage tank; a 21,000 gallon chlorine contact chamber; a 41.09 acre spray irrigation area consisting of 18 zones ; and all associated piping, valves, controls, and appurtenances to serve the S & J Villari Livestock WWTF, with no discharge of wastes to surface waters, pursuant to the application received April 22, 2020, subsequent additional information received July 6, 2020 and September 8, 2020, and in conformity with the Division -approved plans and specifications considered a part of this permit. This permit shall be effective from the date of issuance through November 30, 2025, shall void Permit No. WQ0016376 issued January 3, 2020, and shall be subject to the following conditions and limitations: I. SCHEDULES Upon completion of construction and prior to operation of the permitted modifications, the Permittee shall submit an engineering certification from a North Carolina licensed Professional Engineer certifying that the permitted facility has been constructed in accordance with G.S. 143-215.1, Administrative Code Title 15A Subchapter 02T, this permit, and the Division -approved plans and specifications. For phased and partially certified facilities, the Permittee shall retain the responsibility to track further construction approved under this permit, and shall provide a final engineering certification upon project completion. Mail the Engineering Certification to the Division of Water Resources, Non -Discharge Branch, 1617 Mail Service Center, Raleigh, NC 27699-1617, or Non- Discharge.Reports&ncdenr.gov. [15A NCAC 02T .0116(a)] WQ0016376 Version 4.1 Shell Version 200201 Page 1 of 11 2. The Permittee shall notify the Wilmington Regional Office, telephone number (910) 796-7215, at least two business days in advance of initial operation of the constructed facilities so that the Division can conduct a startup inspection. [15A NCAC 02T .0108(b)(1)(B)] 3. Prior to operation of the newly installed facilities, a Final Operation and Maintenance Plan shall be submitted for review. The plan shall be sent to the Division of Water Resources, Non -Discharge Branch, 1617 Mail Service Center, Raleigh, NC 27699-1617 or Non-Discharge.Reportskncdenr.gov. [15A NCAC 02T .0108(b)(1)(B), 02T .0507(a)] 4. The Permittee shall request renewal of this permit on Division -approved forms no later than June 3, 2025. [15A NCAC 02T .0105(b), 02T .0109] II. PERFORMANCE STANDARDS The Permittee shall maintain and operate the subject non -discharge facilities so there is no discharge to surface waters, nor any contravention of groundwater or surface water standards. In the event the facilities fail to perform satisfactorily, including the creation of nuisance conditions due to improper operation and maintenance, or failure of the irrigation areas to assimilate the effluent, the Permittee shall take immediate corrective actions, including Division required actions, such as the construction of additional or replacement wastewater treatment or disposal facilities. [15A NCAC 02T .0108(b)(1)(A)] 2. This permit shall not relieve the Permittee of their responsibility for damages to groundwater or surface water resulting from the operation of this facility. [15A NCAC 02T .0108(b)(1)(A)] 3. Groundwater monitoring wells shall be constructed in accordance with 15A NCAC 02C .0108 (Standards of Construction for Wells Other than Water Supply), and any other jurisdictional laws and regulations pertaining to well construction. [15A NCAC 02C .0108] 4. Effluent quality shall not exceed the limitations specified in Attachment A. [15A NCAC 02T .0505(b)] 5. Application rates, whether hydraulic, nutrient, or other pollutant, shall not exceed those specified in Attachment B. [15A NCAC 02T .0505(c), 02T .0505(n)] 6. Wastewater irrigation fields permitted on or after December 30, 1983 have a compliance boundary that is either 250 feet from the wastewater irrigation area, or 50 feet within the property boundary, whichever is closest to the wastewater irrigation area. Any exceedance of groundwater standards at or beyond the compliance boundary shall require corrective action. Division -approved relocation of the compliance boundary shall be noted in Attachment B. Multiple contiguous properties under common ownership and permitted for use as a disposal system shall be treated as a single property with regard to determination of a compliance boundary. [15A NCAC 02L .0106(d)(2), 02L .0107(b), 02T .0105(h), G.S. 143-215.1(1), G.S. 143-215.1(k)] 7. The review boundary is midway between the compliance boundary and the wastewater irrigation area. Any exceedance of groundwater standards at or beyond the review boundary shall require preventative action. [15A NCAC 02L .0106(d)(1), 02L .0108] 8. The Permittee shall apply for a permit modification to establish a new compliance boundary prior to any sale or transfer of property affecting a compliance boundary (i.e., parcel subdivision). [ 15A NCAC 02L .0107(c)] 9. No wells, excluding Division -approved monitoring wells, shall be constructed within the compliance boundary except as provided for in 15A NCAC 02L .0107(g). [15A NCAC 02L .0107] WQ0016376 Version 4.1 Shell Version 200201 Page 2 of 11 10. Except as provided for in 15A NCAC 02L .0107(g), the Permittee shall ensure any landowner who is not the Permittee and owns land within the compliance boundary shall execute and file with the Duplin County Register of Deeds an easement running with the land containing the following items: a. A notice of the permit and number or other description as allowed in 15A NCAC 02L .0107(f)(1); b. Prohibits construction and operation of water supply wells within the compliance boundary; and c. Reserves the right of the Permittee or the State to enter the property within the compliance boundary for purposes related to the permit. The Director may terminate the easement when its purpose has been fulfilled or is no longer needed. [15A NCAC 02L .0107(f)] 11. The facilities herein were permitted per the following setbacks: a. Fields 1-14 were originally permitted July 27, 2000, July 3, 2003, and April 2, 2004. The setbacks for spray irrigation sites originally permitted or modified from February 1, 1993 to August 31, 2006 are as follows (all distances in feet): i. Each habitable residence or place of assembly under separate ownership: 400 1 ii. Each private or public water supply source: 100 iii. Surface waters: 100 iv. Groundwater lowering ditches: 100 v. Surface water diversions (upslope): 100 vi. Surface water diversions (downslope): 100 vii. Each well with exception of monitoring wells: 100 viii. Each property line: 150 '` ix. Top of slope of embankments or cuts of two feet or more in vertical height: 15 x. Each water line: 10 xi. Each swimming pool: 100 xii. Public right of way: 50 xiii. Nitrification field: 20 xiv. Each building foundation or basement: 15 ' Habitable residences or places of assembly under separate ownership constructed after the facilities herein were originally permitted or subsequently modified are exempt from this setback. 2 Setbacks to property lines are not applicable when the Permittee, or the entity from which the Permittee is leasing, owns both parcels separated by the property line. [15A NCAC 02H .02190)(5)] WQ0016376 Version 4.1 Shell Version 200201 Page 3 of 11 b. Fields 15-17 were originally permitted May 17, 2013. The setbacks for spray irrigation sites originally permitted or modified from September 1, 2006 to August 31, 2018 are as follows (all distances in feet): i. Each habitable residence or place of assembly under separate ownership: 400 1 ii. Each habitable residence or place of assembly owned by the Permittee: 200 iii. Each private or public water supply source: 100 iv. Surface waters: 100 v. Groundwater lowering ditches: 100 vi. Surface water diversions: 25 vii. Each well with exception of monitoring wells: 100 viii. Each property line: 150 2 ix. Top of slope of embankments or cuts of two feet or more in vertical height: 15 x. Each water line: 10 xi. Subsurface groundwater lowering drainage systems: 100 xii. Each swimming pool: 100 xiii. Public right of way: 50 xiv. Nitrification field: 20 xv. Each building foundation or basement: 15 ' Habitable residences or places of assembly under separate ownership constructed after the facilities herein were originally permitted or subsequently modified are exempt from this setback. 2 Setbacks to property lines are not applicable when the Permittee, or the entity from which the Permittee is leasing, owns both parcels separated by the property line. [15A NCAC 02T .0506(a), 02T .0506(e), 02T .0506(fl] c. The storage and treatment units were modified May 17, 2013. The setbacks for storage and treatment units originally permitted or modified from September 1, 2006 to August 31, 2018 are as follows (all distances in feet): i. Each habitable residence or place of assembly under separate ownership: 1001 ii. Each private or public water supply source: 100 iii. Surface waters: 50 iv. Each well with exception of monitoring wells: 100 v. Each property line: 50 2 ' Habitable residences or places of assembly under separate ownership constructed after the facilities herein were originally permitted or subsequently modified are exempt from this setback. 2 Setbacks to property lines are not applicable when the Permittee, or the entity from which the Permittee is leasing, owns both parcels separated by the property line. [15A NCAC 02T .0506(b), 02T .0506(e), 02T .0506(f)] WQ0016376 Version 4.1 Shell Version 200201 Page 4 of 11 III. OPERATION AND MAINTENANCE REQUIREMENTS 1. The Permittee shall operate and maintain the subject facilities as anon -discharge system. [15A NCAC 02T .0500] 2. The Permittee shall maintain an Operation and Maintenance Plan, which shall include operational functions, maintenance schedules, safety measures, and a spill response plan. [15A NCAC 02T .0507(a)] 3. Upon the Water Pollution Control System Operators Certification Commission's (WPCSOCC) classification of the subject non -discharge facilities, the Permittee shall designate and employ a certified operator in responsible charge (ORC), and one or more certified operators as back-up ORCs. The ORC or their back-up shall operate and visit the facilities as required by the WPCSOCC. [15A NCAC 02T .0117] 4. The Permittee shall maintain vegetative cover on the irrigation sites, such that crop health is optimal, allows even effluent distribution, and allows inspection of the irrigation system. [15A NCAC 02T .0507(b)] 5. The Permittee shall take measures to prevent effluent ponding in or runoff from the irrigation sites listed in Attachment B. [15A NCAC 02T .0507(c)] 6. The Permittee shall not irrigate treated effluent during inclement weather, or when the soil is in a condition that will cause ponding or runoff. [15A NCAC 02T .0505(x)] 7. Irrigation equipment shall be tested and calibrated once per permit cycle. [15A NCAC 02T .0507(d)] 8. Only treated effluent from the S & J Villari Livestock WWTF shall be irrigated on the sites listed in Attachment B. [15A NCAC 02T .0501] 9. The Permittee shall not allow vehicles or heavy machinery on the irrigation area, except during equipment installation or maintenance activities. [15A NCAC 02T .0507(e)] 10. The Permittee shall prohibit public access to the wastewater treatment, storage, and irrigation facilities. [15A NCAC 02T .0505(q)] 11. The Permittee shall dispose or utilize generated residuals in a Division -approved manner. [15A NCAC 02T .0508, 02T .I 100]. 12. The Permittee shall not divert or bypass untreated or partially treated wastewater from the subject facilities. [15A NCAC 02T .05050)] 13. Freeboard in the 3.65 MG facultative lagoon and the 1.88 MG above -ground stainless steel storage tank shall not be less than two feet at anytime. [15A NCAC 02T .0505(d)] 14. Gauges to monitor waste levels in the 3.65 MG facultative lagoon and the 1.88 MG above -ground stainless steel storage tank shall be provided. These gauges shall have readily visible permanent markings, at inch or tenth of a foot increments, indicating the following elevations: maximum liquid level at the top of the temporary liquid storage volume; minimum liquid level at the bottom of the temporary liquid storage volume; and the lowest point on top of the dam. [15A NCAC 02T .0507(f)] 15. A protective vegetative cover shall be established and maintained on all berms, pipe runs, erosion control areas, surface water diversions, and earthen embankments (i.e., outside toe of embankment to maximum allowable temporary storage elevation on the inside of the embankment). Trees, shrubs, and other woody vegetation shall not be allowed to grow on the earthen dikes or embankments. Earthen embankments shall be kept mowed or otherwise controlled and accessible. [15A NCAC 02T .0507(g)] WQ0016376 Version 4.1 Shell Version 200201 Page 5 of 11 16. Metering equipment shall be tested and calibrated annually. [15A NCAC 02T .0507(d)] IV. MONITORING AND REPORTING REQUIREMENTS The Permittee shall conduct and report any Division required monitoring necessary to evaluate this facility's impact on groundwater and surface water. [15A NCAC 02T .0108(c)] 2. A Division -certified laboratory shall conduct all analyses for the required effluent, groundwater, and surface water parameters. [15A NCAC 02H .0800] 3. Flow through the treatment facility shall be continuously monitored, and daily flow values shall be reported on Form NDMR. Facilities with a permitted flow less than 10,000 GPD may estimate their flow from water usage records provided the water source is metered. [15A NCAC 02T .0105(k), 02T .0108(c)] 4. The Permittee shall monitor the treated effluent at the frequencies and locations for the parameters specified in Attachment A. [15A NCAC 02T .0108(c)] 5. The Permittee shall maintain records tracking the amount of effluent irrigated. These records shall include the following information for each irrigation site listed in Attachment B: a. Date of irrigation; b. Volume of effluent irrigated; c. Site irrigated; d. Length of time site is irrigated; e. Continuous weekly, monthly, and year-to-date hydraulic (inches/acre) loadings; f. Continuous monthly and year-to-date loadings for any non -hydraulic parameter specifically limited in Attachment B; g. Weather conditions; and h. Maintenance of cover crops. [15A NCAC 02T .0108(c)] 6. Freeboard (i.e., waste level to the lowest embankment elevation) in the 3.65 MG facultative lagoon and the 1.88 MG above -ground stainless steel storage tank shall be measured to the nearest inch or tenth of a foot, and recorded weekly. Weekly freeboard records shall be maintained for five years, and shall be made available to the Division upon request. [15A NCAC 02T .0108(c)] 7. Three copies of all monitoring data (as specified in Conditions IV.3. and IVA.) on Form NDMR for each PPI and three copies of all operation and disposal records (as specified in Conditions IV.S. and IV.6.) on Form NDAR-I, and three copies of all field loading records on Form NDMLR for every site in Attachment B shall be submitted on or before the last day of the following month. NDMLR data shall include cover crop type and PAN loading for each month as well as cumulative PAN loading for the year. If no activities occurred during the monitoring month, monitoring reports are still required documenting the absence of the activity. All information shall be submitted to the following address: Division of Water Resources Information Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 [15A NCAC 02T .0105(l)] WQ0016376 Version 4.1 Shell Version 200201 Page 6 of 11 8. The Permittee shall maintain a record of all residuals removed from this facility. This record shall be maintained for five years, and shall be made available to the Division upon request. This record shall include: a. Name of the residuals hauler; b. Non -Discharge permit number authorizing the residuals disposal, or a letter from a municipality agreeing to accept the residuals; c. Date the residuals were hauled; and d. Volume of residuals removed. [15A NCAC 02T .0508(b)] 9. A maintenance log shall be kept at this facility. This log shall be maintained for five years, and shall be made available to the Division upon request. This log shall include: a. Date of flow measurement device calibration; b. Date of irrigation equipment calibration; c. Visual observations of the plant and plant site; and d. Record of preventative maintenance (e.g., changing of equipment, adjustments, testing, inspections and cleanings, etc.). [15A NCAC 02T .0507(h)] 10. Monitoring wells MW-1, MW-2, MW-3, MW-5, MW-6, MW-7, MW-8, and MW-9 shall be sampled at the frequencies and for the parameters specified in Attachment C. All mapping, well construction forms, well abandonment forms and monitoring data shall refer to the permit number and the well nomenclature as provided in Attachment C and Figure 1. [15A NCAC 02T .0105(m)] 11. Two copies of the monitoring well sampling and analysis results shall be submitted on a Compliance Monitoring Form (GW-59), along with attached copies of laboratory analyses, on or before the last working day of the month following the sampling month. The Compliance Monitoring Form (GW-59) shall include this permit number, the appropriate well identification number, and one GW-59a certification form shall be submitted with each set of sampling results. All information shall be submitted to the following address: Division of Water Resources Information Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 [15A NCAC 02T .0105(m)] 12. An annual representative soils analysis (i.e., Standard Soil Fertility Analysis) shall be conducted on each irrigation site listed in Attachment B. These results shall be maintained at the facility for five years, and shall be made available to the Division upon request. Each Standard Soil Fertility Analysis shall include the following parameters: Acidity Exchangeable Sodium Percentage Phosphorus Base Saturation (by calculation) Magnesium Potassium Calcium Manganese Sodium Cation Exchange Capacity Percent Humic Matter Zinc Copper pH [15A NCAC 02T .0108(c)] WQ0016376 Version 4.1 Shell Version 200201 Page 7 of 11 13. Noncompliance Notification: The Permittee shall report to the Wilmington Regional Office, telephone number (910) 796-7215, within 24 hours of first knowledge of the following: a. Treatment of wastes abnormal in quantity or characteristic, including the known passage of a hazardous substance. b. Any process unit failure (e.g., mechanical, electrical, etc.) rendering the facility incapable of adequate wastewater treatment. c. Any facility failure resulting in a discharge to surface waters. d. Any time self -monitoring indicates the facility has gone out of compliance with its permit limitations. e. Ponding in or runoff from the irrigation sites. Emergencies requiring reporting outside normal business hours shall call the Division's Emergency Response personnel at telephone number (800) 662-7956, (800) 858-0368, or (919) 733-3300. All noncompliance notifications shall file a written report to the Wilmington Regional Office within five days of first knowledge of the occurrence, and this report shall outline the actions proposed or taken to ensure the problem does not recur. [15A NCAC 02T .0108(b)(1)(A)] V. INSPECTIONS 1. The Permittee shall perform inspections and maintenance to ensure proper operation of the wastewater treatment and irrigation facilities. [15A NCAC 02T .0507(i)] 2. The Permittee shall inspect the wastewater treatment and irrigation facilities to prevent malfunctions, facility deterioration, and operator errors that may result in discharges of wastes to the environment, threats to human health, or public nuisances. The Permittee shall maintain an inspection log that includes the date and time of inspection, observations made, and maintenance, repairs, or corrective actions taken. The Permittee shall maintain this inspection log for a period of five years from the date of the inspection, and this log shall be made available to the Division upon request. [15A NCAC 02T .0507(h), 02T .0507(i)] 3. Division authorized representatives may, upon presentation of credentials, enter and inspect any property, premises, or place related to the wastewater treatment and irrigation facilities permitted herein at any reasonable time for determining compliance with this permit. Division authorized representatives may inspect or copy records maintained under the terms and conditions of this permit, and may collect groundwater, surface water, or leachate samples. [G.S. 143-215.3(a)(2)] WQ0016376 Version 4.1 Shell Version 200201 Page 8 of 11 VI. GENERAL CONDITIONS 1. Failure to comply with the conditions and limitations contained herein may subject the Permittee to a Division enforcement action. [G.S. 143-215.6A, 143-215.613, 143-215.6C] 2. This permit is effective only with respect to the nature and volume of wastes described in the permit application, and Division -approved plans and specifications. [G.S. 143-215.1(d)] 3. Unless specifically requested and approved in this permit, there are no variances to administrative codes or general statutes governing the construction or operation of the facilities permitted herein. [15A NCAC 02T .0105(n)] 4. The issuance of this permit does not exempt the Permittee from complying with all statutes, rules, regulations, or ordinances that other jurisdictional government agencies (e.g., local, state, and federal) may require. [15A NCAC 02T .0105(c)(6)] 5. If the permitted facilities change ownership, or the Permittee changes their name, the Permittee shall submit a permit modification request on Division -approved forms. The Permittee shall comply with all terms and conditions of this permit until the permit is transferred to the successor -owner. [G.S. 143- 215.1(d3)] 6. The Permittee shall retain a set of Division -approved plans and specifications for the life of the facilities permitted herein. [15A NCAC 02T .0105(o)] 7. The Permittee shall maintain this permit until the proper closure of all facilities permitted herein, or until the facilities permitted herein are permitted by another authority. [15A NCAC 02T .01050)] 8. This permit is subject to revocation or modification upon 60-day notice from the Division Director, in whole or part for: a. violation of any terms or conditions of this permit or Administrative Code Title 15A Subchapter 02T; b. obtaining a permit by misrepresentation or failure to disclose all relevant facts; c. the Permittee's refusal to allow authorized Department employees upon presentation of credentials: I. to enter the Permittee's premises where a system is located or where any records are required to be kept; ii. to have access to any permit required documents and records; iii. to inspect any monitoring equipment or method as required in this permit; or iv. to sample any pollutants; d. the Permittee's failure to pay the annual fee for administering and compliance monitoring; or e. a Division determination that the conditions of this permit are in conflict with North Carolina Administrative Code or General Statutes. [15A NCAC 02T .0110] WQ0016376 Version 4.1 Shell Version 200201 Page 9 of 11 9. Unless the Division Director grants a variance, expansion of the facilities permitted herein shall not occur if any of the following apply: a. The Permittee or any parent, subsidiary, or other affiliate of the Permittee has been convicted of environmental crimes under G.S. 143-215.6B, or under Federal law that would otherwise be prosecuted under G.S. 143-215.6B, and all appeals of this conviction have been abandoned or exhausted. b. The Permittee or any parent, subsidiary, or other affiliate of the Permittee has previously abandoned a wastewater treatment facility without properly closing the facility. c. The Permittee or any parent, subsidiary, or other affiliate of the Permittee has not paid a civil penalty, and all appeals of this penalty have been abandoned or exhausted. d. The Permittee or any parent, subsidiary, or other affiliate of the Permittee is currently not compliant with any compliance schedule in a permit, settlement agreement, or order. e. The Permittee or any parent, subsidiary, or other affiliate of the Permittee has not paid an annual fee. [15A NCAC 02T .0120(b), 02T .0120(d)] 10. This permit shall not be renewed if the Permittee or any affiliation has not paid the required annual fee. [15A NCAC 02T .0120(c)] Permit issued this the 20'h day of October 2020 NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION 7L46..�-z S. Daniel Smith, Director Division of Water Resources By Authority of the Environmental Management Commission Permit Number WQ0016376 WQ0016376 Version 4.1 Shell Version 200201 Page 10 of 11 Permit No. WQ0016376 S & J Villari Livestock LLC S & J Villari Livestock WWTF ENGINEERING CERTIFICATION ❑ Partial ❑ Final Wastewater Irrigation System October 20, 2020 Duplin County I, , as a duly licensed North Carolina Professional Engineer, having ❑ periodically / ❑ fully observed the construction of the permitted facilities, do hereby state to the best of my abilities that the facility was constructed in compliance with G.S. 143-215.1, Administrative Code Title 15A Subchapter 02T, this permit, and the Division -approved plans and specifications. Documentation of any variation to this permit, and the Division -approved plans and specifications, is in the attached as -built drawings. Description of variations: Professional Engineer's Name Firm Name Firm No. Address City JL State Zip Code Telephone Email Seal, Signature, and Dateaj THE COMPLETED ENGINEERING CERTIFICATION, INCLUDING ALL SUPPORTING DOCUMENTATION, SHALL BE SENT TO THE FOLLOWING ADDRESS: NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION OF WATER RESOURCES NON -DISCHARGE BRANCH By U.S. Postal Service By Courier/Special DelivM 1617 MAIL SERVICE CENTER 512 N. SALISBURY ST. RALEIGH, NORTH CAROLINA 27699-1617 RALEIGH, NORTH CAROLINA 27604 WQ0016376 Version 4.1 Shell Version 200201 Page 11 of 11 THIS PAGE BLANK ATTACHMENT A — LIMITATIONS AND MONITORING REQUIREMENTS PPI 001— WWTF Effluent Permit Number: WQ0016376 Version: 4.1 EFFLUENT CHARACTERISTICS EFFLUENT LIMITS MONITORING REQUIREMENTS PCS Code Parameter Description Units of Measure Monthly Average Monthly Geometric Mean Daily Minimum Daily Maximum Measurement Frequency Sample Type 00310 BOD, 5-Day (20 °C) mg/L Monthly Grab 00940 Chloride (as Cl) mg/L 3 x Year' Grab 50060 Chlorine, Total Residual mg/L Weekly Grab 31616 Coliform, Fecal MF, M-FC Broth, 44.5 °C #/100 mL Monthly Grab 50050 Flow, in Conduit or thru Treatment Plant GPD 100,260 Continuous Recorder 00610 Nitrogen, Ammonia Total (as N) mg/L Monthly Grab 00625 Nitrogen, Kjeldahl, Total (as N) mg/L Monthly Grab 00620 Nitrogen, Nitrate Total (as N) mg/L Monthly Grab 00600 Nitrogen, Total (as N) mg/L Monthly Grab 00400 pH su Weekly Grab 00665 Phosphorus, Total (as P) mg/L Monthly Grab 70300 Solids, Total Dissolved — 180 °C mg/L 3 x Year' Grab 00530 Solids, Total Suspended mg/L Monthly Grab 3 x Year monitoring shall be conducted in March, July, and November. WQ0016376 Version 4.1 Attachment A Page 1 of 2 PPI 002 - Surface Water Monitoring Upstream EFFLUENT CHARACTERISTICS EFFLUENT LIMITS MONITORING REQUIREMENTS PCS Code Parameter Description Units of Measure Monthly Average Monthly Geometric Mean Daily Minimum Daily Maximum Measurement Frequency Sample Type 31616 Coliform, Fecal MF, M-FC Broth, 44.5 °C #/100 mL Monthly Grab 00610 Nitrogen, Ammonia Total (as N) mg/L Monthly Grab 00625 Nitrogen, Kjeldahl, Total (as N) mg/L Monthly Grab 00620 Nitrogen, Nitrate Total (as N) mg/L Monthly Grab 00600 Nitrogen, Total (as N) mg/L Monthly Grab 00665 Phosphorus, Total (as P) mg/L Monthly Grab PPI 003 - Surface Water Monitoring Downstream EFFLUENT CHARACTERISTICS EFFLUENT LIMITS MONITORING REQUIREMENTS PCs Code Parameter Description Units of Measure Monthly Monthly Daily Minimum Daily Maximum Average Geometric Mean Measurement Frequency Sample Type 31616 Coliform, Fecal MF, M-FC Broth, 44.5 °C #/100 mL Monthly Grab 00610 Nitrogen, Ammonia Total (as N) mg/L Monthly Grab 00625 Nitrogen, Kjeldahl, Total (as N) mg/L Monthly Grab 00620 Nitrogen, Nitrate Total (as N) mg/L Monthly Grab 00600 Nitrogen, Total (as N) mg/L Monthly Grab 00665 j Phosphorus, Total (as P) j mg/L j Monthly Grab WQ0016376 Version 4.1 Attachment A Page 2 of 2 ATTACHMENT B - APPROVED LAND APPLICATION SITES AND LIMITATIONS Permit Number: WQ0016376 Version: 4.1 S & J Villari Livestock LLC - S & J Villari Livestock WWTF IRRIGATION AREA INFORMATION APPLICATION LIMITATIONS Field Owner County Latitude LongitudejNeDominant Parameter Hourly Yearly Double Units Soil Series Rate Max Cro in1 S & J Villari Livestock LLC Duplin 35.007257' -78.120914'Norfolk 01284 - Non -Discharge Application Rate 0.6 41.96 inches WQ09 - Plant Available Nitro en - Loadin 300 350 lbs/acre 2 S & J Villari Livestock LLC Duplin 35.007076' -78.120648'Norfolk 01284 - lant Discharge Application Rate 0.6 41.96 inches WQ09 -Plant Available Nitro en -Loadin 300 350 lbs/acre 3 S & J Villari Livestock LLC Duplin 35.006930° -78.120309°Norfolk 01284 - Non -Discharge Application Rate 0.6 41.96 inches WQ09 - Plant Available Nitrogen - Loading 300 350 lbs/acre 4 S & J Villari Livestock LLC Duplin 35.006808° -78.119948°Norfolk 01284 - Non -Discharge Application Rate 0.6 41.96 inches WQ09 - Plant Available Nitrogen - Loading 300 350 lbs/acre 5 S & J Villari Livestock LLC Duplin 35.006687° -78.119725° 1.19 Norfolk 01284 - Non -Discharge Application Rate 0.6 41.96 inches WQ09 - Plant Available Nitrogen - Loading 300 350 lbs/acre 6 S & J Villari Livestock LLC Duplin 35.006577' -78.119378' 1.17 Norfolk 01284 - Non -Discharge Application Rate 0.6 41.96 inches WQ09 - Plant Available Nitrogen - Loading 300 350 lbs/acre 7 S & J Villari Livestock LLC Duplin 35.008520' -78.119198' 1.05 Norfolk 01284 - Non -Discharge Application Rate 0.6 41.96 inches WQ09 - Plant Available Nitrogen - Loading 300 350 lbs/acre 8 S & J Villari Livestock LLC Duplin 35.007946' -78.119001 ° 1.25 Norfolk 01284 - Non -Discharge Application Rate 0.6 41.96 inches WQ09 - Plant Available Nitrogen - Loading 300 350 lbs/acre 9 S & J Villari Livestock LLC Duplin 35.007752' -78.119358' 1.00 Norfolk 01284 - Non -Discharge Application Rate 0.6 41.96 inches WQ09 - Plant Available Nitrogen - Loading 300 350 lbs/acre 10 S & J Villari Livestock LLC Duplin 35.006378' -78.119018' 1.46 Goldsboro 01284 - Non -Discharge Application Rate 0.6 41.96 inches WQ09 - Plant Available Nitrogen - Loading 300 350 lbs/acre 11 S & J Villari Livestock LLC Duplin 35.006798' -78.118499' 1.43 Norfolk 01284 - Non -Discharge Application Rate 0.6 41.96 inches WQ09 - Plant Available Nitrogen - Loading 300 350 lbs/acre 12 S & J Villari Livestock LLC Duplin 35.006555' -78.118001' 1.23 Norfolk 01284 - Non -Discharge Application Rate 0.6 41.96 inches WQ09 - Plant Available Nitrogen - Loading 300 350 lbs/acre 13 S & J Villari Livestock LLC Duplin 35.008212' -78.118708' 2.19 Goldsboro 01284 - Non -Discharge Application Rate 0.6 41.96 inches WQ09 - Plant Available Nitrogen - Loading 300 350 lbs/acre 14E RSJ Properties, LLC 1 Duplin 35.010430' -78.120250' 13.73 Goldsboro 01284 - Non -Discharge Application Rate 0.6 31.60 inches WQ09 - Plant Available Nitrogen - Loading 300 350 lbs/acre 14W RSJ Properties, LLC i Duplin 35.011560' -78.121484' 7.70 Goldsboro 01284 - Non -Discharge Application Rate 0.6 24.21 inches WQ09 - Plant Available Nitrogen - Loading 300 350 lbs/acre 15 S & J Villari Livestock LLC Duplin 35.007315' -78.119095' 0.73 Norfolk 01284 - Non -Discharge Application Rate 0.6 30.44 inches WQ09 - Plant Available Nitrogen - Loading 300 1 350 lbs/acre 16 S & J Villari Livestock LLC Duplin 35.008628° -78.120044° 1.25 Goldsboro 01284 - Non -Discharge Application Rate 0.6 13.83 inches WQ09 - Plant Available Nitrogen - Loading 300 350 lbs/acre 17 S & J Villari Livestock LLC Duplin 35.008315° -78.121265' 0.82 Bibby 01284 - Non -Discharge Application Rate 0.5 16.95 inches WQ09 -Plant Available Nitrogen -Loadin 300 350 lbs/acre Totals 41.09 1. An easement recorded in the Duplin County Register of deeds (BK: 1906 PG: 489-493) allows the use of the parcel of land owned by RSJ Properties, LLC by S & J Villari Livestock LLC for the irrigation of treated wastewater WQ0016376 Version 4.1 Attachment B Page 1 of 1 THIS PAGE BLANK ATTACHMENT C — GROUNDWATER MONITORING AND LIMITATIONS Permit Number: WQ0016376 Version: 4.1 Monitoring Wells: MW-1, MW-2, MW-3, MW-5, MW-6, MW-7, MW-8, and MW-9 GROUNDWATER CHARACTERISTICS GROUNDWATER STANDARDS MONITORING REQUIREMENTS PCS Code Parameter Description Daily Maximum Frequency Measurement Sample Type Footnotes 00680 Carbon, Tot Organic (TOC) mg/L 3 x Year Grab 1,6 00940 Chloride (as Cl) 250 mg/L 3 x Year Grab 1 31616 Coliform, Fecal MF, M-FC Broth, 44.5 °C #/100 mL 3 x Year Grab 1 00610 Nitrogen, Ammonia Total (as N) 1.5 mg/L 3 x Year Grab 1 00620 Nitrogen, Nitrate Total (as N) 10 mg/L 3 x Year Grab 1 00400 pH 6.5-8.5 su 3 x Year Grab 1,2 00665 Phosphorus, Total (as P) mg/L 3 x Year Grab 1 70300 Solids, Total Dissolved - 180 °C 500 mg/L 3 x Year Grab 1 GWVOC Volatile Compounds (GW) Present: Yes/No Annually Grab 1, 4, 5 82546 Water Level, Distance from measuring point feet 3 x Year Calculated L2,3 1. 3 x Year monitoring shall be conducted in March, July, and November; Annual monitoring shall be conducted in November. 2. The measurement of water levels shall be made prior to purging the wells. The depth to water in each well shall be measured from the surveyed point on the top of the casing. The measurement of pH shall be made after purging and prior to sampling for the remaining parameters. 3. The measuring points (top of well casing) of all monitoring wells shall be surveyed to provide the relative elevation of the measuring point for each monitoring well. The measuring points (top of casing) of all monitoring wells shall be surveyed relative to a common datum. 4. Volatile Organic Compounds (VOC) - In November only, analyze by one of the following methods: a. Standard Method 6230D, PQL at 0.5 gg/L or less b. Standard Method 6210D, PQL at 0.5 gg/L or less c. EPA Method 8021, Low Concentration, PQL at 0.5 gg/L or less d. EPA Method 8260, Low Concentration, PQL at 0.5 gg/L or less e. Another method with prior approval by the Water Quality Permitting Section Chief Any method used shall meet the following qualifications: a. A laboratory shall be DWR certified to run any method used. b. The method used shall include all the constituents listed in Table VIII of Standard Method 6230D. c. The method used shall provide a PQL of 0.5 gg/L or less that shall be supported by laboratory proficiency studies as required by the DWR Laboratory Certification Unit. Any constituents detected above the MDL but below the PQL of 0.5 gg/L shall be qualified (estimated) and reported. 5. If any volatile organic compounds (VOC) are detected as a result of monitoring as provided in Attachment C, then the Wilmington Regional Office supervisor, telephone number (910) 796-7215, shall be contacted immediately for further instructions regarding any additional follow-up analyses required. 6. If TOC concentrations greater than 10 mg/L are detected in any downgradient monitoring well, additional sampling and analysis shall be conducted to identify the individual constituents comprising this TOC concentration. If the TOC concentration as measured in the background monitor well exceeds 10 mg/L, this concentration will be taken to represent the naturally occurring TOC concentration. Any exceedances of this naturally occurring TOC concentration in the downgradient wells shall be subject to the additional sampling and analysis as described above. 7. Monitoring wells shall be reported consistent with the nomenclature and location information provided in Figure 1 and this attachment. WQ0016376 Version 4.1 Attachment C Page 1 of 1 Figure 1 - S & J Villari Livestock WWTF