Loading...
HomeMy WebLinkAboutSW8121101_APPROVED PLANS_20121126STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW DOC TYPE ❑ CURRENT PERMIT APPROVED PLANS HISTORICAL FILE ❑ ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE 4�_,r0 YYYYMMDD OWNER: EASTERN PRIDE, INC. 2405—F NASH STREET WILSON, NC GENERAL CONTRACTOR — STOCKS AND TAYLOR CONSTRUCTION, INC WASHINGTON, NC SUMMARY OF SITE: GENERAL BUILDING INFORMATION BUILDING USE: COMMERCIAL - RETAIL BUILDING SIZE: 9180 SF BUILDING INFO: LOT SIZE 0,92 AC. ZONING INFORMATION: ZONING HB SETBACKS: MINIMUM BUILDING SETBACKS (UNLESS NOTED) FRONT 25 FEET SIDE: 10' FT REAR; 20 FEET UTILITIES: WATER LINE-ONWASA (EXACT LOCATION TO BE DETERMINED IN THE FIELD) WASTEWATER - ONWASA WASTEWATER SERVICE: 4"SEWER WATER SERVICE: 3/4" WATER SERVICE ELECTRIC SERVICE- PROGRESS ENERGY NATURAL GAS - N/A ALL NEW SERVICES SHALL MEET ALL NC BUILDING CODE REQUIREMENTS ALL EXISTING UTILITIES ARE SHOWN BASED ON FIELD EVIDENCE PRIOR TO ANY D#GGING NC ONE CALL SHALL BE CALLED AND CONFIRM LOCATION AND SIZE OF ALL EXISTING UTILITIES. —STOP POST PER, PLAN O O O � N I o� FENCE TO MEET TOWN STANDARDS I l I / \ I / \ I A - p P b A ASPHALT PAVEMENT PLAN r- ST DOUBLE GATE W/ WHEEL SUPPORTS W/ WWF —6" REINFORCED CONCRETE PAD - 3000 P,S1. NOTE: STOP POST AND FRONT BOLLARDS SHALL 6" STEEL PIPE, CONCRETE FILLED. THE EXPOSED � '0 LENGTH SHALL BE 4' ABOVE GROUND WITH A BURY DEPTH OF 3'. POSTS SHALL BE N '0 VERTICALLY LEVEL IN AN 18" DIAMETER HOLE BACK FILLED WITH 3000 PSI CONCRETE, 8" SECTION A -A DUMPSTER PAD DETAIL Scale: Not To Scale; { "r 4v,f135 �3" 57Il� ' Sw Mix . Q° �' j LE a iESf#Ttafi OR SON rt a thraq 4c�T$' :a rR tea. i DUMPSTER PAD (2) W/ 6' WOODEN FENCE FOR BUFFER CD EX. AXLE 6" BG 20' L 6' WOODEN FENCE FOR BUFFER ., nDRAIN LINE V_ PARKING REQUIREMENTS Q0 >n PARKING SPACES TO BE TYPICAL (9 FEET X 20 FEET) UNLESS w OTHERWISE NOTED w O PARKING SPACES REQUIRED: 24 _ PARKING BUILDING CODE REQUIREMENTS; (1 SPACE PER 400 SF RETAIL ) LLJ < 0 PARKING PROVIDED TOTAL - 30 LL_ N HANDICAPPED ACCESSIBLE - 2 HANDICAPPED ACCESSIBLE PARKING TO BE (2 EQUAL SPACES) PER LOCAL CODE o O � m 0 w w 0 2" SURFACE COURSE '00:11, SAND FILTER DA 1 ABC STONE 3 PROPOSED tD 2" FORCE MAIN r �. SEE SHEET C003 �--- 1 \`---- COMPACTED SUBGRADE PROP. 171 1 TYPICAL PAVEMENT SECTION EX. »AXLE Scale: Not To Scale: R/W- 313 AS "TEAL. ik I i t�l �I 4AtAPS TOTAL t r 25 11" OVERALL 74315 E= 4 OVEI ry. 30. FT.- 70.0 SIGN UPTO BE MWED BY LANDLORD "00 PICIrT MNCZ SEAS d��La. - LO FOR "TER1! USE 114 SUPPORT TO MNV,t 01WCT :tsuRIAIL FOUNDAMN N 3744' 120 W 1 _ h 20 P 21 X 22 ?r o z PROP, 8'X8'X4" THICK CONC PAD W/ 6"DIA STEEL BOLLARDS PLACED BY OWNER 199.69' EX. AXLE ® 6" BG MECHANICAL PADS a.. 0. 0.. � 4-- 5X5 ? 102.0 w 13.9 Q jv SITE BENCHMARK IOP �a} • NAIL IN UTILITY POLE I © G U ELEV. = 62.03 — PROP. 4 GUY THICK CONC PAD WIRE _-----10 01MR/4'// 9180 SF BUILDING % %' ww CONDENSER PAO I a 3' X 6' I FAMILY DOLLAR STORE 440 FF EL. 63w1. 24 HANDICAP RAMP ��38/�� ���/'' %,' `r�/,,�/.% �'`;"'% y PROPOSED 26 , /��/ % UNDERGROUND O //�/ �. 6 DIA STEEL �! ELECTRIC SERVICE w BOLLARDS TO BE w 1 I 1n Ln �/ c 27 w ASPHALT �,'� / / a it�/- ,/ ,r PLACED ALONG I PARKING - , /�� SIDEWALK 6' 4" 0/C I 0:� CD L 28 I 8' MONO THIC SIDEWALK �. � Z -, \ — 23 � y"�� Ln 2a.o im z 0 C9 U L c N LLJ 30 �� ��%, 3 ® o ® O ' o w 4 j t� Q /i %/ V, �a Cp Ili. z c a c R5.0 W �,� Q�OC •� ° :,i o = 10.0— >C �ljc.r � Li w 0 IN GR#NDER �Lj R2,5 o PUMP STATION ASPHAL PARKIN@ m Z Is PYLON I c w 14 15 ;5 PAR ING C� L`!PSE OF w IRRIGATION TAP At 9'X 0' (T)P) LEANING �`\ SEE NOTE BELOW 1 " EIS 36 5' L NDSCAPE BU ER 12' AG -____ �. _ --•- -- ---- T _� r� L (2 0;l -2) EMN 0 0 0 o a o O o O o a a o rs o 0 0 o w P V?'p 'fv IM4 E �:i�•%� 6" WAT R INE SIGHT TRIANGLE W EW L W BRADFORD PEAR TREE \ CURB & GUTTER----'" T DR P INLET CURB INLET OP = 59.51' BRADFORD CURB & GUTTER �� TOP OF GRATE = 61.55' Q �, INV. = 56.61' PEAR TREE -- ,N '-1'46'n�;" E INV. = 55.75 m 5C.94' X REMOVE V) _r IVO �5 O/jV4 _ff 7 US JH!�! 0 EX, 18" RCP SD D SD CURB INLET TOP OF GRATE = 61.52' R W w INV. = 55.22' DROP INLET I TOP = 59.36' l Mn/cr r% l rn EX, LIGHT POLES AND WIRING SSS O3 w 700 1 L//i S 37°34'27" E 467.57' TO A MNS (202) AT THE CL INTERSECTION w OF U.S. 258/N.C. 24 WITH CHURCH STREET STANDARD NCDOT STREET TYPE ENTRANCE W/ EXPRESSWAY GUTTER 8" ABC STONE R W 2" SURFACE COURSE """"""' " i PROPOSED - (2) 3/4" WATER METER W/ BACKFLOW PREVENTER AND RPZ IN HOT BOX WITH ELECTRICAL TO PREVENT FREEZING Z SITE PLAN SCALE: i° =z©' �ENEf�At- NOTES C A ,1 l �0 1. ANY EXISTING ROOTS EXPOSED BY CONSTRUCTION ACTIVITY LANDSCAPE LEGEND SHALL BE SEVERED CLEANLY WITH A PRUNING TOOL. j KEY QTY SCIENTIFIC NAME COMMON NAME PLANTING SIZE CATEGORY TYPE Do NOT DISPOSE OF ANY CHEMICALS, PETROLEUM PRODUCTS, OR REMOVE SOIL ANY OUTSIDE THE LIMIT OF WORK, DY 1 Ilex vo.m,'oria '� lana' ! Dwa,,f Yojp,-,n > o Iy 18'� j 3 dal. SHRUB{SHALL) — EVEP(;RE��" 3. LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THE LOCATION E LC1CA ON OF ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR REPAIRING DAMAGE TO ANY UTILITIES AS A .^'� .S_ .r r RfiGp�!I�,,.,�I 7�IC I H # ndian �N _iE�� 1 'S r 1 '� t�� . �H �� l�j �I�� ��_� / - —R N � E (;�R���,�; LMDSCAP-E. NOTES RESULT OF INSTALLING ANY LANDSCAPE MATERIALS, 1. LOCATE ALL EXISTINE_ JTILITIES PRIOR TO INSTALLATION OF PLANT MATERIAL. NOTIFY ENGINEER OF ANY DISCREPANCIES BETWEEN FIELD CONDITIONS A` _, THOSE SHOWN IN PLAN 2. ALL PLANT MATERIAL SHALL CONFORM WITH THE STANDARDS SET FORTH BY THE AMERICAN ASSOCIATION OF NURSERYMEN AND THE WRITTEN SPECIFICATI:­S. 3. PLANTING BEDS TO EE MULCHED WITH A MINWUM OF 3" LONGLEAF PINESTRAW. ALL PLANT GROUPINGS SHALL BE MULCHED AS ON BED. 4. ESTABLISH POSITIVE DRAINAGE IN ALL PLANTING BEDS AND AWAY FROM BUILDINGS. 5, APPLY PRE-EMERGAi;- HERBICIDE TO ALL NEW PLANTING BEDS AT MANUFACTURER'S RECOMMENDED RATE PRIOR TO INSTALLATION OF MULCH, 6. DO NOT INSTALL PLANT MATERIAL IN IMPERVIOUS SOILS(i.e. HOLES WHICH, WHEN FILLED WITH WATER, DO NOT COMPLETELY DRAIN WITHIN TWO HOURS.) 7, MAX HEIGHT OF PLA""-S CAN NOT EXCEED 2' HEIGHT PER LOCAL ORDINANCE TOWN ORDINANCE RE- _ _ REMF VT FOR LANDSCAPING Off street parking areas for more than ten (10) vehicles shall be effective) screened by a vegetive buffer, fence, or berm, or a combination of these screcnin devices. SITE �' JACKSONVILLE U.S.' '2.i6/N.G. 24 FINAL PLANS FOR REVIEW ONLY��' NOT FOR CONSTRUCTION VICINITY SKETCH W T TO $ME j 411- �.. ,+`�i�1iI11Nfff�,, SEAL. - 20212 �= r� • � ti� � PfH,LE PAMLICO ENGINEERING SERVICES, PLLC LICENSE NO. P-0530 Im PAMLICO ENGINEERING SERVICES 128 Abbey Lane Washington, NC 27889 252-945-2983 pespllc@embarqmail.com LIj a J Li J W W � 3 W W U+ p d N Q 0 Q a ¢ Z }� Q � J � a W � a � V N r Q Z o vs z r a O w � w W VV W W ¢Z¢ 2 Z U 6 44) U U ? r D C N N V N D N U 6 \p \ \ O fie No. 12024 Scale: 1 = 20' Sheet No. G001 'y,^Y �.�r,` 1,�� ��yFI if>♦j t.r. rl V.� 4, •Yf -.� f, ..i t V �� }. r I Y •N� I ` ri 1J 1. y '�,�� k FI� OWNER: EASTERN PRIDE, INC. 2405--F NASH STREET WI LSON, NC GENERAL CONTRACTOR - STOCKS AND TAYLOR CONSTRUCTION, INC WASHINGTON, INC SAND FILTER SCHEDULE AREA NUMBER 1 DISTURBED AREA AC 0,95 IMPERVIOUS AREA 0,543 TOTAL DRAINAGE AREA 0,916 WATER QUALITY VOLUME ADJ 2183 VOLUME PROVIDED 2250 NORTH STORM DRAINAGE STRUCTURE DATA ITEM RIM INV OUT EX CB 1 CONVERT TO DI 61,55 55.50 EX DI CONVERT TO SDMH 59.51 56.61 OVERFLOW STRUCTURE 59.5 55.8 SILT FENCE TO FOLLOW PROPERTY LINE I AND DFLINIATES LIMITS OF DISTRURBANCE;. / PER NPDES REQUIREMENTS % HE AREA WITH SLOPES GREATER THAN 3:1 SHALL BE SEEDED IN 7 DAYS it PROP. SWALE TO , DIVERT SITE ,WATER INTO BMP 1 WEIR TO BE USED AS A FLOW SPLITTER DEVICE / DURING STORM EVENTS GREATER THAN 1 YR 24 HR EVENT THE SWALE WILL OVERFLOW TO AVOID ADDITIONAL DRAINAGE INTO THE SAND FiLTER,USE SOD TO ESTABLISH / GROUND COVER AND PREVENT EROSION i OF THE BANK, WEIR EL. = 60.15 / L= 10' / �n / w O / W / -1 Q _j n w N NJAI JDM JUIS PERMIT REQUIRE ME TO DO? ILL- !f} EROSION CONTROL CONSTRUCTION SEQUENCE YOU SHOULD READ AND BECOME FAMILIAR WITH THE PROVISIONS OF THIS PERMIT. 1. OBTAIN AND POST COPY OF CERTIFICATE OF EROSION CONTROL PLAN APPROVAL. BELOW IS A LIST OF THE MAJOR REQUIREMENTS, WITH INDICATIONS WHERE THOSE DIFFER >- CO 2. INSTALL EROSION CONTROL DEVICES AS INDICATED ON THE DRAWINGS OR SPECIFIED IN THE SPECIFICATIONS. FROM THE PREVIOUS CONSTRUCTION GENERAL PERMIT. Q m 3. ONCE EROSION CONTROL DEVICES ARE INSTALLED, BEGIN CONSTRUCTION OPERATIONS. SAND FILTER 1 8" ROOF DRAIN 5IL I FENCE EP AT 0.4% PR'OPERTY LINEALONG REAR 62.30 INV 60.83 , 17 INV OUT 60 EP i N 3744 W 62.46 199. /.` \ - z 57 / ` 59 /� / `'� / V / / > 60 IL TSW '� I Of EP 1.96 EP y / . �, ���;/ / / , �; ,,� /� : j ; CL 60.00 ;! y� 9180 S1= BUILDING TBM (SITE) , / NAIL IN UTILITY POLE FAMILY DOLLAR STORE EL 62.03 FF EL. 63 Q ASPHALT TSW ING 62.50 46/ TSW � � v- r / ./ J/O � LLJ E /..._ TSW ��Q0 Q �, \ �- �< a 6 .65 62.80 10' MONOLITHIC SIDEWALK 63.00EP >E z z 0 62.50 w I U = Ln 4. MAINTAIN EROSION CONTROL DEVICES AS NECESSARY DURING CONSTRUCTION. INSPECT DEVICE AFTER EVERY EROSION AND SEDIMENT CONTROL PAN DA 1 0 � _ 'j/ E to �,/.. ,; W , Q RAINFALL EVENT AND CLEAN OUT SILT FENCE A5 NEEDED � � i; ;�. ;:r '\ 5. AS CONSTRUCTION PROGRESSES, INSTALL ADDITIONAL EROSION CONTROL DEVICES A5 INDICATED ON THE YOU MUST IMPLEMENT THE EROSION AND SEDIMENTATION CONTROL PAN APPROVED FORVOL = 2250 CF Ld I 60.85 j / j / EP z r� O YOUR PROJECT BY THE DIVISION OF LAND RESOURCES OR BY AN APPROVED LOCAL 0 EP � ./ \ W Q � cc 62 10 DRAWINGS, CALLED FOR 11,4 THE SPECIFICATIONS, OR AS NEEDED OR DIRECTED BY ENGINEER. PROGRAM, ADHERENCE TO THAT E&SC PLAN IS AND ENFORCEABLE COMPONENT OF THE 6. SEED AND MULCH DISTURBED AREAS AS STATED BELOW BASED ON WORKING DAYS: STORM WATER PERMIT. A. UPON COMPLETION OF ANY PHASE OF CONSTRUCTION B. WHEN WORK WILL NOT PROCEED 1N AN AREA WITHIN THE ABOVE TIME FRAME. YOUR E&SC PLAN WILL IDENTIFY AREAS WHERE THE MORE STRINGENT 7 AND 14 DAY 7. AFTER SITE IS STABILIZED, REQUEST AN INSPECTION BY THE ENGINEER. UPON APPROVAL OF SITE "NEW STABILIZATION, REMOVE TEMPORARY EROSION DEVICES, DRESS OUT AREA AND SEED AND MUCH. PERMANENT GROUND STABILIZATION REQUIREMENTS APPLY. SEE GROUND STABILIZATION EROSION CONTROL DEVICES SHALL BE INSTALLED AND APPROVED BY ENGINEER. REQUIREMENTS" ON PAGE 2. CHISEL COMPACTED AREAS AND SPREAD TOPSOIL 4 INCHES DEEP OVER ADVERSE SOIL MONITORING AND _INSPECTIONS YOU MUST KEEP A RAIN GAUGE ON SITE. CONDITIONS, IF APPLICABLE. • DEDICATED DEMOLITION AND OTHER WASTE AREAS AND EARTHEN MATERIAL STOCKPILES MUST BE LOCATED AT LEAST 50' FROM STORM DRAINS OR STREAMS RIP THE ENTIRE AREA TO 6 INCHES DEPTH. UNLESS NO ALTERNATIVE IS FEASIBLE NEW REQUIREMENT). . YOU MUST INSPECT ALL E&SC MEASURES AT LEAST ONCE A WEEK AND WITHIN 24 REMOVE ALL LOOSE ROCK, ROOTS, AND OTHER OBSTRUCTIONS LEAVING SURFACE HOURS AFTER ANY STORM EVENT GREATER THAN A HALF INCH (DURING A REASONABLY SMOOTH AND UNIFORM. 24-HOUR PERIOD). YOU MUST TAKE IMMEDIATE CORRECTIVE ACTION FOR ANY DEVICE FAILURE. • YOU MUST INSPECT ALL OUTLETS WHERE STORM WATER RUNOFF LEAVES YOUR SITE APPLY AGRICULTURAL LIME, FERTILIZER, AND SUPERPHOSPHATE UNIFORMLY AND MIX AND EVALUATE THE EFFECT ON NEARBY STREAMS OR WETLANDS, OR CAUSES A WITH SOIL. VISIBLE INCREASE IN TURBIDITY (CLOUDINESS) OF ANY WATER BODY. • YOU MUST KEEP RECORDS OF THESE INSPECTIONS AND ANY CORRECTIVE ACTIONS CONTINUE TILLAGE UNTIL A WELL --PULVERIZED, FIRM. REASONABLY UNIFORM SEEDBED IS TAKEN. PREPARED 4 TO 6 INCHES DEEP. OPERATION &-JIMINTENANCE SEED ON FRESHLY PREPARED SEEDBED AND COVER SEED LIGHTLY WITH SEEDING YOU MUST PROVIDE THE OPERATION AND MAINTENANCE NECESSARY TO MAINTAIN OPTIMAL EQUIPMENT OR CULTIPACK AFTER SEEDING. PERFORMANCE OF STORM WATER CONTROLS. THIS MEANS TAKE CORRECTIVE ACTION IF EROSION AND SEDIMENT CONTROL FACILITIES ARE NOT OPERATING PROPERLY! OPERATION AND MAINTENANCE INCLUDES, BUT IS NOT LIMITED TO: MULCH IMMEDIATELY AFTER SEEDING AND ANCHOR MULCH. REGULARLY CLEANING OUT SEDIMENTATION BASINS. INSPECT ALL SEEDED AREAS AND MAKE NECESSARY REPAIRS OR RESEEDING WITHIN STABILIZING ERODED BANKS OR SPILLWAY STRUCTURES, THE PLANTING SEASON, IF POSSIBLE. IF STAND SHOULD BE OVER 60% DAMAGED, • REPAIRING/CLEARING OUT INLETS AND OUTLETS. REESTABLISHED FOLLOWING ORIGINAL LIME, FERTILIZER AND SEEDING RATES. REPAIRING PIPING, SEEPAGE AND MECHANICAL DAMAGE. • REPAIRING SILT FENCE DAMAGE. NOTE: CONTRACTOR SHALL PROVIDE A PERMANENT SEED COVER ON ALL AREAS DISTURBED 82ORMUG, DURING CONSTRUCTION OPERATIONS, INCLUDING ANY DISTURBANCE TO THOSE AREAS REGULAR INSPECTIONS ARE A CHANCE TO CHECK IMPACTS TO NEARBY WATERS. IF ANY OBSERVE SEDIMENT THAT HAS DEPOSITED IN A STREAM OR WETLAND, YOU MUST NOTIFY THAT WERE SEEDED DURING PREVIOUS WORK, THE DIVISION OF WATER QUALITY REGIONAL OFFICE WITHIN 24 HOURS AND PROVIDE WRITTEN NOTICE WITHIN 5 DAYS SEE #3 ON PAGE 6 OF THE GENERAL PERMIT). PLEASE SEND A - COPY OF THIS CORRESPONDENCE TO THE DIVISION OF LAND RESOURCES (DLR), Sfte.AmotE i StAbllIzathm Ti frame E:xs pElons SON-CMEUANGE &kes, swales, d40l afW slams 7 clays None TAKE COMPLIANCE SERIOUSLY! PROJECTS THAT VIOLATE STORM WATER PERMIT CONDITIONS -- � AND/OR HAVE UNAUTHORIZED WATER QUALITY IMPACTS ARE SUBJECT TO FINES. CIVIL ky " High Iaita#tiyWater 'HOW1 Zones 7 Nnne PENALTIES OF UP TO $25,000.00 PER DAY FOR EACH VIOLATION MAY BE ASSESSED_ S e t fi than . t 7 If stapes are I D' or toss in Ten gm d are net Meter than P t , 14 days a e altwt. L-,,, stopes 3:1 € f "Atter a 14 days 7 stays for slopes qfealor than - 0' in lenq h cw.-, Ali othef areas wAh sk4ms flatter than 4:1 14 days, None, except tw perimeters and. HOW Zones. NOTE, DIMENSIONS SHOWN ON SITE PLAN ACTUAL AREAS FOR DESIGN WERE OVERFLOW STRUCTURE TO BE CONSTRUCTED DURING THE TAKEN FROM ACAD GENERATED CONSTRUCTON OF THE SAND FILTERS PRIOR TO INSTALLATION CONTOURS OF THE DRAW DOWN WEIR ALL SEDIMENT SHALL BE CLEANED OUT AND DISPOSED OF OFF SITE IN AN APPROVFD PIT, A PRECAST AS +AF = TOTAL SURFACE AREA AND FILTER CHAMBER OR 8" BLOCK STRUCTURE CAN BE USED FOR CONSTRUCTION 550 + 680 = 1230 SF SURFACE AREA 680 SF SEE 15" PIPE DATA C7R INVERTS OVERI=LOW ELE = 5( j FOR EARTHEN EMBANKMENT SHALL BE HOMOGENEOUS AND CLASS CL 1, CL- 2 OR CH 3:1 SIDE SLOPE (TYP) STA&LIZE DITCH BANK WITH MATTING SURFACE AREA 550 SF CHAMBER TO BE BUILT OF CONCRETE WITH A WATER STOP AT THE FOOTING TO AVOID OUND WATER INTO THE SYSTEM SEE DETAIL SHEET FOR DESIGN INFORMATION. 3:11 SIRE -- - EL. I I I I I I SLOPE TY , IN SHWT EL, 55,5 #57 CLEAN STONE 6" DEEP WITH FILTER FABRIC SAND FILTER 1 BETWEEN SAND AND STONE 1 NT5 - 62.30 62 %/ ,� I d m u e Cq EP �do< EP 62.20 L1] ��V us SRRU SEE DETAIL / 60.6 � ASPHALT I O I 3 RIM I �� 61.30 PARKING �/1[7 / l cat �I���i(!a r' � � i< � EP X z zm...1 62.30 \ / EP j fi2.4Q �/, X 1 1I PROP 1.5"C002 a��/�� 61.63 EP Ioe t C;_--. INV IN=55.8 \; t_JJ 62.38 INV OUT =55.7 l EP �:� �9 EP ` ,�-62,50 ' 61.00 �� � i E 199,7W_ SEAL - - 20212 -- - - - - - - - --- ---- -E ©z EX. DI 1 NCDOT STD - - REMOVE FRAME AND GRATE - EP AND 12" PIPE 61.27 PLUG BOX AND FILL WITH EP - PAMLICO ENGINEERING SERVICES, PLLC SUITABLE MATERAIL ENTRANCE x A 61.76 _ _ W LICENSE NO. P-0530 71 1) THE PROPERTY IS SHOWN ON FLOOD INSURANCE RATE MAP 3720443200J, DATED NOV 3, 2005 AND THE PROPERTY IS NOT LOCATED IN A SPECIAL FLOOD HAZARD AREA 2) ALL N.C. GRID DATA SHOWN HEREON IS BASED ON NAD 1983 2007 ADJUSTMENT USING THE NCGS RTK NETWORK SYSTEM, 3) ALL DISTANCES SHOWN HEREON ARE N.0 GRID DISTANCES UNLESS OTHERWISE NOTED, 4) COMBINED GRID FACTOR=0.999888330 5) ALL ELEVATIONS SHOWN HEREON ARE BASED ON MEAN SEA LEVEL NAVD 1988, ALL SPOT ELEVATIONS ARE TOP OF ASPHALT UNLESS OTHERWISE NOTED CONTOURS ARE SHOWN IN 1' INCREMENTS 6) NO WETLANDS ON THIS TRACT OF LAND SD W HMIff..4T Ho. z5a H1CIM r Ho• zf too' RI)r W -� v3 - - -DSD 128 Abbey Lane CONTRACTOR TO SAWCUT EX. CURB & GUTTER Washington, NC 27889 EX, CB 1 NCDOT STD REMOVE DRIVE ENTRANCE AND REPLACE WITH T REMOVE GRATE AND FRAME NEW CURB 252-945-2953 INSTALL A NCDOT W pespllc@embargmail.com STD. TO FIT EXISTING F311X H2O LOADING RIM 61.55 z GRADING PLAN 2 SCALE; 1" =20' a 0 FINAL N z 70' MIN. 35' MIN. 15' MIN. NEW CONSTRUCTION W PLANS C f. BUT SUFFICIENT TO KEEP EXISTING ROADWAY SEDIMENT ON SITE Ex. CB �- INV 55.5 SEEDING PLAN B" MIN. 1. TEMPORARY SEEDING 2'-3" STONE TO BE USED 25' OR WIDTH OF SAND FILTER MEDIA PLANING DATES Q2ASS TYPE POUNDSfACRE EXISTING (SURGE STONE OR RAILROAD PROPOSED STREET. TO MEET ASTM C 33 DEC. 1 - APR. 15 RYE (GRAIN) 120 ROADWAY BALLAST) WHICHEVER IS - 15" CUTLET PIPE KOBE LESPEDEZA 50 GREATER. SEE DATA IN PLAN SHEET APR. 15 - AUG. 15 GERMAN MILLET 40 AUG. 15 - DEC. 1 RYE (GRAIN) 120 LIME 3,000 FERTILIZER 10-10-10 800 - 4" HDPE PERFORATED PIPE MULCH STRAW 4,000 SMC'JTH WALL WITH 3/" PERFORATION SPAS. NG MAX WIDTH 10' O/C 2, PERMANENT SEEDING PLAN VIEW PLANING DATES GRASS TYPE POU A .RE SEPT. 1 - OCT. 3 TALL FESCUE 200 KOBE LESPEDEZA 50 RYE (GRAIN) 25 LIME 4,000 FERTILIZER 10-10-10 1,000 MULCH STRAW 4,000 FOR REVIEW ONLY • 12 MIN. NOT FOR CONSTRUCTION f\�\\�/% a \��-FABR'/IC UNDER STONE NQTF$: U a z v 1. PUT SILT FENCE OR TREE PROTECTION FENCE UP TO ENSURE 0 CROSS SECTION CONSTRUC710N ENTRANCE IS USED. } N � r � STANDARD CONSTRUCTION ENTRANCE 2• IF CONSTRUCTION ON THE SITES ARE SUCH THAT THE MUD a 8 IS NOT REMOVED BY THE VEHICLE TRAVELING OVER THE STONE. THEN THE TIRES OF THE VEHICLES MUST BE WASHED scale: Not To Scale. BEFORE ENTERING THE PUBLIC ROAD. He No. 2024 Scale: rl f! = 20' BOUDNARY SURVEY AND TOPO PROVIDED BY: Sheet No. JQh'NNY J. X1Z1_1AJfS LAND :S11,gV _r1NG', P. C. C�002 54 P.4. BOX rm, , N.C. =III PHONE:910-M-W72 FAX 91O-M-2310 EMAIL : JW11.11AriSOMSURVEY.00M FIRM NO. C-2532 n r, : r Qr . - ,_r: t�., II y , � I.1 1 !' i ,-, A, r A ef4 .�, r �.- ,�J. �4 ♦1� t= Y j{. +� � rr' !�j-`i r '�. sl i r J r - 1:,. , rr i � ,..- � i.L. Ly �.! 4l 1+ r r.! It. yh S.,. l♦ 1 '�. IL �rf..�I L3i.'.): t [ r •',-�i ' •, - r rl 4 r e i . . �. -, T'. '... :�., 5. ., iLlA, � .. .l, S.,S, .yf ll •,`Y _t.*lh FA; iC. lS tV. ­-1, 1., . A . . . _ 2. i ... .. .'L.. .. 1 . .... t ! _ e 1. . _. , S . 1. 1 . _ [ a _. a j . — r . -_- _ . 1 L _ a . u — 1. . r_ . . I _-- INSTALLATION OF NETTING AND MATTING PRODUCTS DESIGNED TO CONTROL EROSION SHOULD BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS, ANY MAT OR BLANKETTYPE PRODUCT USED AS PROTECTIVE MULCH SHOULD PROVIDE COVER OF AT LEAST 30% OF THE SURFACE WHERE IT IS APPLIED, INSTALLATION IS ILLUSTRATED BELOW. 1. APPLY LIME, FERTILIZER AND SEED BEFORE LAYING THE NET OR MAT, IF OPENWEAVENETTING IS USED. LIME MAY BE INCORPORATED BEFORE INSTALLING THE NET AND FERTILIZER AND SEED SPRAYED ON AFTERWARD. 2. START LAYING THE NET FROM THE TOP OF THE CHANNEL OR SLOPE AND UNROLL IT DOWN THE GRADE, ALLOW NETT#NG TO LAY LOOSELY ON THE SOIL BUT WITHOUT WRINKLES --DO NOT STRETCH. 3. TO SECURE THE NET, BURY THE UPSLOPE END IN A SLOT OR TRENCH NO LESS THAN 6 INCHES DEEP, COVER WITH SOIL, AND TAMP FIRMLY. STAPLE THE NET EVERY 12 INCHES ACROSS THE TOP END AND EVERY 3 FT AROUND THE EDGES AND BOTTOM, WHERE 2 STRIPS OF NET ARE LAID SIDE BY SIDE, THE ADJACENT EDGES SHOULD BE OVERLAPPED 3 INCHES AND STAPLED TOGETHER, EACH STRIP OF NETTING SHOULD ALSO BE STAPLED DOWN THE CENTER, EVERY 3 FT. DO NOT STRETCH THE NET WHEN APPLYING STAPLES. 4. TO JOIN TWO STRIPS, CUT A TRENCH TO ANCHOR THE END OF THE NEW NET. OVERLAP THE END OF THE PREVIOUS ROLL 18 INCHES, AND SAMPLE EVERY 12 INCHES JUST BELOW THE ANCHOR SLOT, MAINTENANCE �fl1q ff�fff INSPECT ALL MULCHES PERIODICALLY, AND AFTER RAINSTORMS TO CHECK fff�ff\��ff\f\ FOR RILL OBSERVED, APPLY ADDITIONAL TMULCH. FFILUWASHOUTROCCURS, REPAIR �Iffffff\\III THE SLOPE GRADE, RESEED, AND REINSTALL MULCH. CONTINUE INSPFCTIQNS UNTIL VEGETATION IS FIRMLY ESTABLISHED. 1 TEMP. DITCH LINER Scale: Not TO Scale, 12,-0" MINIMUM IU ASPHALT DRIVEWAY +� ENTRANCE EXISTING EDGE OF PAVEMENT PLAN VIEW El 66.85 kN CHANNELS, ROLL OUT STRIPS OF NETTING PARALLEL TO THE DIRECTION OF FLOW AND OVER THE PROCTECTIVE MULCH, HOR NETTING iN A OVERLAP NCH TRFNCH JOIN STRIPS BY ANCHORING AND OVERLAPPING. 1 -COMMERCIAL AND INDUSTRIAL DRIVEWAYS TO BE A MAXIMUM OF 36 FEET WAD£, SWALE TYP -ALL CONCRETE SHALL BE 3000 P.S.I. *-ELEVATION "B" MINUS ELEVATION "A" EQUALS 1 INCH. NTS DRIVEWAY ENTRANCE WITH ASPHALT DRIVEWAY MAXIMUM RECOMMENDED GRADES ENTRANCE WITH B" ABC STONE 5-0 AND AND 2" AS ALT Xyp"N EXISTING PAV$1lE�LT O.B1G 51-0" COMPACTED 5 -0• `2 BACKFILL TYPICAL _SEQTION NOTES. 1. CURB SHALL BE TAPERED TO FINISH FLUSH WITH SIDEWALK. 2. BEGINNING RADIUS SHALL NOT ENCROACH ON ADJACENT PROPERTIES BASED ON A PROJECTION OF THE PROPERTY LINE FROM THE RIGHT OF WAY TO THE CURB LINE 3. SIDEWALK SECTION SHALL NOT BE REQUIRED ALONG STREETS WHICH ARE NOT PLANNED FOR SIDEWALK. NCDOT DRIVEWAY ENTRANCE 35' MIN. 15' MIN. NEW CONSTRUCTION EXISTING ROADWAY B" MIN. 25' OR WIDTH OF PROPOSED STREET, WHICHEVER IS GREATER. FABRIC UNDER STONE CROSS SECTION --Ljwz 12" MIN. 70' MIN. BUT SUFFICIENT TO KEEP SEDIMENT ON SITE NOTES: 2"-3" STOVE TO BE USED 1, PUT SILT FENCE OR TREE PROTECTION FENCE UP TO ENSURE EXISTING (SURGE STONE OR RAILROAD CONSTRUCTION ENTRANCE IS USED. ROADWAY BALLAST) 2. IF CONSTRUCTION ON THE SITES ARE SUCH THAT THE MUD IS NOT REMOVED BY THE VEHICLE TRAVELING OVER THE STOVE, THEN THE TIRES OF THE VEHICLES MUST BE WASHED BEFORE ENTERING THE PUBLIC ROAD. PLAN VIEW STANDARD CONSTRUCTION ENTRANCE 6 Scale: Not To Scale: 811 —r v FILTE FABRIC TO BE KEYED INTO TOP OF SLOPE AND USED IN AREAS WHERE A PERMANENT STAND OF GRASS IS NOT ACQUIRED. z TYP. SLOPE DETAIL Scale: Not To Scale: NOTE: SEE GRADING PLAN FOR ALL ELEVATIONS 8" CAST IN PLACE WALLS WITH 3000 PSI CONCRETE. WATER STOP TO BE INSTALLED BETWEEN FOOTING AND WALL POURS, STRUCTURE TO 5 SAND FILTER BASIN Scale: Not To Scale: TOP OFC WIER EL 59.J 15" PIPE 8 15" PIPE #4 @ 12" O. C, E, W, 5 OVERFLOW STRUCTURE Scale: Not To Scale: MINIMUM 10 GAUGE LINE WIRES a � VARIABLE AS �IFiEa C13Y ��} E ENGINEER SILT FENCE FABRIC { -- INSTALLED TO SECOND -- WIRE fROMMK T , ,., -yam- L�J 119109 ►�'II L'.9 � SILT FENCE Scale: Not To Scale: PERMANENT SEEDING ON ALL SLOPES REMOTE MOUNTED NMPLCX CONTROL PANEL TYPICAL INSTALLATION 48" SIMPLEX 2HP GRINDER PUMP PACKAGE W SRA-125-CV UFTOUT WITH RpMO MOUNTED CONTROL PANEL (MODELS 812SRO-3060P THRU 912SRO-30192P) PUMP MODEL: �w SIMPLEX JUNCTION BOX, 1 1 2_ CONDUIT FLANGE STRUC7_ PLASTIC EL 61.5 Cd 3� INLET FITTING -� I (FIELD INSTALLEDS I Et 58..5 kNVEl ..5 LL 58,0 HIGH WA7ER ALARM LIFT BAIL. SST — (A9 REWD.5 "8- DIA. BASIN - TOP RAIL SUPPORT SST Ad' DA- BASIN COVER, SOLID EPDXY COATED STEEL JUNCTION BOX 55T FASTENER5 RAIL SUPPORT FLANGE. 557 AN11-FLC7A 110N VALVE Ek TENBfON HANDLE COLLAR ' 1 AN11-SIPHON O VALVE. LVE, PVC (A$ REOTIS ] WiDC RAILS. T- %H. 10 SST t 1/2" 615C11ARCE FAx ] C1!ST IRON A 7 DISCHARGE LEVEL LIFTOU7 CHAIN, 1/4' S5T 1 1/4" DISCHARGF PIPE, PVC SCH. 80 EL 57 PUMP ON LEVEL EL 54 PUMP OFF LEVEL •• �' " MYERS 5RA-12^ -CV- LIFTOUT .._ :. (M/CHECK VALVE} 1W:1� 2HP 4PIN ER PUMP SHOWN ✓ CONCRE7f AN11-FLOTATION SASE RC i- 3 1/2 CU, FT. FOR EACH FOOT OF BA STEEL POST WOVEN WIRE FABRIC SILT FENCE FABRIC 3'-0"� FILL SLOPE MINIMUM 12— /2119AU INTERMEDIATE WI S ji: Anr r-- GRADE B' MINIMUM COVER 2'—O' OVER SKIRT * ANCHOR SKIRT AS DIRECTED BY ENGINEER SIDE VIEW USE SILT FENCE ONLY WHEN DRAINAGE AREA DOES NOT EXCEED 1/4 ACRE AND NEVER IN AREAS OF CONCENTRATED FLOW. CONTROL 1400NTINC BRACKE7. S37. � (�-DISCHARGE FLANGE 1 i `7 T 4' YALL VAL1y��,, P 1C I11110N, BWp4'A 71PE T I/i" ANTI -SIPHON VALVE PVC WASTEWATER GRINDER PUMP STATION 3/8-14UHC x 2 iO, ANCHOR STUD J4) RLO'D NTS I C3nslow water c;c Sewet Authority 22j�I'H (JST BLOC KIN(, FINAL PLANS FOR REVIEW ONLY NOT FOR CONSTRUCTION a, CL o, W J Q W W 0 i I i120 mjum a � e 1 t r- I 5 ns ow Water $r Sewer Authority vv � I'E�OPOSF.I')1JTiLIT 2 OVER i XIS'ITNG STORM SEWER ° 'Y V I� 0 I CM a SEAL r � ? 20212 % z1 '�lllf111111�1�, i PAMLICO ENGINEERING SERVICES, PILL LICENSE NO. P-0530 PAMLICO ENGINEERING SERVICES 128 Abbey Lane Washington, NC 27889 _ 252-945-2983 pespllc@embargmail.com I I— w J o 0 LIJ 0 Q I le No.12024 - I swic NTS Sheet No. C-00