HomeMy WebLinkAboutSW8061010_COMPLIANCE_20060901STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW&)60ro DOC TYPE ❑ CURRENT PERMIT ❑ APPROVED PLANS ❑ HISTORICAL FILE COMPLIANCE EVALUATION INSPECTION DOC DATEI�i� YYYYMMDD STORMWATER PLAN NARRATIVE Shallotte Electric Stores Expansion September 2006 Milliken Properties Limited Partnership plans to expand their Shallotte Electric Supply facilities located at 4871 Southport — Supply Road (NC 211) The current site has one metal building with gravel drive, parking, storage, and natural areas The site area is 2 8 acres of which approximately 22% is currently "built -upon" The proposed project includes the addition of two metal buildings, asphalt drive and parking, and gravel staging area The built -upon area following the completion of the project will be approximately 47% This project drams to Jump & Run Creek which is classified as SC,Sw A wet detention pond will be used to treat the stormwater runoff Runoff will be collected by drop inlets, storm drains, and vegetative swales and shall be directed to the wet detention pond The pond outlet shall discharge to the adjacent NC 211 roadside ditch The pond and outlet are designed to detain the runoff from a 1-inch rainfall for three to four days The pond is also designed to limit the 10-year peak runoff following construction to a value less than the 10- year peak runoff prior to construction Runoff from off -sight areas will be intercepted by swales along the western and southern property lines, therefore, no runoff from off -sight areas will enter the wet detention pond 6934-6 Beach Drive SW Ocean Isle Beach, NC 28469 (910) 575-5872