Loading...
HomeMy WebLinkAboutSW8050515_APPROVED PLANS_20050610STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW S'iU�OSIS DOC TYPE ❑CURRENT PERMIT �PAPPROVED PLANS ❑ HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE YYYYMMDD J 7 7 LEGEND: R/W - Right-of-way q - Centerline MBL - Minimum Building Line S.T. - 10' x 70' Sight Triangle v - Street Sign O- Stop Sign ®- Proposed Elevation - Swale O- Pipe Label ® RRA - Rip Rap Apron B==fl RCD - Rock Check Dan ST #1 - Sediment Trap RCP - Reinforced Concrete Pipe �— - Flow Arrow - Swale Label sf - Silt Fence learing Limits CL - CWetl Existing 6" Water I — d m R EXISTING B" S.S. ... ... -.'.. :. •• f' Tappkg Sleeve 4aO�„FH with Gate Valve Q, C WA TOP-MEG*` ..- ..,,...:. • ..., ,.:.:.• ... .. • P.T. 2 F. 300 L.8" S.S. 10, 2 B.O. T0P�53. 8 I V.-49.05 Woods Line 0950 - Blow -off P.T. - Plug Tapped - Fire Hydrant ® GV - Gate Valve U WM - Water Meter /QEFH - Existing Fire Hydrant m EGV - Existing Gate Valve SET MH OVER �— 1 E— EWM -Existing Water Meter EXISTING LINE f -Water Line w Exist. NOTIFY ENGINEER IF INVERT IS DIFFERENT THAN SHOWN SO THAT THE GRADES MAY BE REVISED. NOTE: Contractor shall Insure that he and all his workers (contractors, subcontractors and other site persomel) do not damags construction stakes or other measures used in laying out the project whether by the Engineer or another entity including Lhasa under the employ of the contractor. Contractor shall cause his workers to observe and verify to the fullest extent practicable that stakes, other n-waasures and grades are, or appear to be, accurate ad correct, and Immediately, but prior to any associated work, notify the staking entity of any potential conflict, error or cyostion regarding the work. The Engineer shall not be responsible If all of the above mneasures are not strictly adhered to. The Engineer shall not be responsible where due to don -age, his staking can not be verified. For critical an costly components of the work, where the cantractor believes that staking may not be preserved, the contractor shall request the staking entity to place staking In an area where Its preservation can be insured. "Sewer Line A" 12 s � 0 a � � EX. 6" WATER 50 NOTIFY ENGINEER IF ACTUAL INVERT IS DIFFERENT THAN SHOWN. - SEWER LINE "A" WO, F THE LANDS TOWNHOMES RICNLANDS TWP., ONSLOW CO., NORTH CAROLINA OWNER: BOB McCALL BUILDERS, INC. P.O. BOX 7573 JACKSONVILLE, NORTH CAROLINA 25540 (910) 265-52I9 ''�'�;, q 4 SEAL 14579(- t. ' �?'•.�;N��NE�? P4,` '•,��0.hY••M•5��,`�,.�' o g v v N si tit ui lu ui W - Parker & Associates, Inc. Consulting Engineers — Land Surveyors — Land Planners �4„� garyb� Sheet No. 5 OF 6 0+00 I+oo 2+00 3+00 P.O. Hog 976 - 26641-0976 606 New Bridge Street - 20540 Designed JAH Jacksonville, North Carolina Phone (910) 455-2414 - Fax (910) 455-3441 Drawn JJL Date 1/11,05 Scale 10.40: F4enane THELANDS-PP Disk AGAD Job No. 5040617-3692 Rev. I /2D/oS JJL- Rev1 sa� M. B. L• ---•, , t . 7 , r• , ,i 7 i :':. Eel � (1.~ lea ti .4 : i^� r 1�; �('. ev C�. P 1