Loading...
HomeMy WebLinkAboutSW8050441_COMPLIANCE_20050915STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW DOC TYPE ❑ CURRENT PERMIT ❑ APPROVED PLANS ❑ HISTORICAL FILE COMPLIANCE EVALUATION INSPECTION DOC DATE r�%F97 J ORl`i WYYMMDD STORMWATER DIVISION CODING SHEET NCG PERMITS PERMIT NO. /v DOC TYPE ❑ HISTORICAL FILE ❑ MONITORING REPORTS DOC DATE ❑ YYYYMMDD WET DETENTION POND ANALYSIS FILE NAME PROJECT #: SW8 050441.sep05 PROJECT NAME: Bobby Morton Project S:IWQSIPOND1050441.sep05.WK1 REVIEWER: L. Lewis DATE: 15-Sep-05 Receiving Stream: UT f � ue Creek Class: SC NSW Drainage Basin: White Oak Index No. WOK02 19-8 Site Area 9.95 acres Drainage Area 2r.925300 square feet Area in Acres 6.41 IMPERVIOUS AREAS Rational C Buildings 66800.00 square feet Parking 136932.00 square feet SW -1435,00 square feet Other 121.00 square feet Future 5000.00 square feet square feet square feet TOTAL1;�t�3t3 00„ square feet Rational Cc= 0.05 SURFACE AREA CALCULATION % IMPERVIOUS 7h.30�V Des. Depth 6 TSS: 90 SAIDA Ratio 4.27% Req. SA 11928 sf Prov. SA 2003sf VOLUME CALCULATION * place a "1" in the box if Rational is used Rational ?* Des. Storm '' 1lJO' inches Rv= 0.728 Bottom 11 msl Perm. Pool ;' 1 r:LO'' msl Design Pool '18.37 msl Storage met @elev 18.29 msl Req. Volume " 1'fi 3t5 cf Vol. Prov. at DP �' J'!.,.18029`�I cf ORIFICE CALCULATION FOREBAY Perm. Pool Volume= 34909 Req. Forebay Volume= 6981.8 Provided Volume= 6834.00 Percent= Elevation Area 17.00 12003.00 18.37 14317.00 Inc. Vol. 18029.20 Ace. Vol. 0.00 18029.20 Avg. Head = s 0.64 ft Q2 Area = 3,65 sq. inches Flow Q2, cfs 0.098 cfs Q5 Area = 1.46 sq. inches Flow Q5, cfs 0.039 cfs Orifice Area 3.14 sq. inches No. of Orifices ,. Q= 0.084 cfs Diameter, inches I'' ..i 2'':C?(�.='.I weir H x W u , in x .' in Drawdown = _ 2'3''f days Surface Area @DP = 14317 sq. ft. Falling Head Drawdown = 3.4 days C: 3.312888889 L= -0.129 COMMENTS Surface Area , Volume and Orifice are within Design Guidelines RECEIVED JUL 12 2005 DWQ t0i # �0 05044• � 1. PROJECT DESCRIPTION µ CA Design Calculations ; =o .• �E5' !29 Stormwater Treatment Facilities 9� for S AL Bobby Morton Development 148 located in Qnslow County ;� / •c�No (Revised April 20, 2005) K. N `tlti0l��, The Project consists of proposed townhomes/businesses on a 7.35 acre tract and associated sitework. 2. COMPUTE POND AREA REQUIRED a. Compute Percent Impervious: Impervious Areas: On -Site Buildings On -Site Streets On -Site Parking On -Site Sidewalks Other on -site Off -site Sub -Total FUTURE FUTURE(reserved) Tota I Total Area Drainage to Pond: Percent Impervious = b. Compute Pond Surface Area 0 205,288 ................................................... 0 5,000 0 210,288 0.753 or 75.3 % Total 66,800 SF 0 SF 136,932 SF 1,435 SF 121 0 205,288 SF 0 5,000 SF 210,288 SF 279,253 SF Using Surface Area to Drainage Area Ratio Chart for 90% TSS Removal (copy attached) and assuming foot pond depth: SAIDA = ;~3' % (interpolated) Therefore: Surface Area = SAIDA x Drainage Area 11,928 SF say;:;€>l=? SF c. Compute Minimum Pond Dimensions Assume rectangular shape with 3:1 Length (L) to Width (W) Ratio: Length = 189.74 feet Width = 63.25 feet Site conditions, however, dictate irregular shaped pond: Hydr. Length = J'feet so, Hydr. Width 46.5 feet (avg) Actual LIW = 4.9 (irregular shape) 3. DETERMINE VOLUME TO BE CONTROLLED FROM 1" STORM Using Schuler "Simple Method": Rv = 0.05 + 0.009(l) where I = percent impervious Rv = 0.728 inlin Control Volume = Design Rainfall x Rv x Drainage Area Control Volume = 16,935 CF 4. DETERMINE REQUIRED STORAGE DEPTH Assume: 3:1 side slopes solving for depth (d) by trial & error: d = 1.51 5. DETERMINE ORIFICE SIZE say €)( CF Control Volume must be drawn down over a 2 day - 5 day period. Using orifice equation, solve for Diameter (D) that results in 3-112 day period: D = (Q 1 0,026 (h) 5)" Where: Q = (Control Volume 1 3.5 days x 86,400 sec/day) 0.060 cfs h=d12 = 0.76 Solving for D: D = 1.62 Use<= € `" pipe Actual Drawdown with actual drawdown pipe diameter (using orifice equation): Q= 0.090 cfs Draw Down Period = 2.31 days OK, < 5.0 6. SELECT OUTLET STRUCTURE DIAMETER Size outlet structure such that depth of 010 flow <1.0 feet: Using Rational Formula (Q=CIA) where: ........................... Cimper CperyMEW Ccum ........................... 11 D = «<v<sT7 in/hr A _ ::.:.:....:.::6.41 ac Q10 = 29.96 cfs Assuming 1/2 circumference is used as weir and using Francis Formula (Q=3.33LH"5) to solve for L such that H = 1.0: L = 9.00 Feet Min 60 inch diameter outlet structure Use 60 inch diameter outlet structure 7. DETERMINE Q10 STAGE Q10 = 29.96 cfs Using Francis Formula (Q=3.33LH'-5) solve for H: H10 = 1.09 feet 8. DETERMINE Q100 STAGE (ELEV. OF EMERGENCY SPILLWAY) Using Rational Formula (Q=CIA) where: Ccum = 0.65 .......................... ........................... 1100 = <` in/hr Q100 = 35.52 Using Francis Formula (Q=3.33LH1'5) solve for H: H 100 = 1.23 feet 9. DETERMINE Q100 STAGE OVER EMERGENCY SPILLWAY (TOP BERM ELEV.) Assume primary spillway blocked (i.e., emergency spillway to accommodate Q100) Emergency spillway shall be a broad crested earthern weir designed to pass 100 year storm. Using broad crested weir equation H = (QICw x L)213 where: Q = Q100 35.52 cfs Cw = 3.0 Length = €<'rCffeet H = 0.44 feet 10. FOREBAY SIZING Compute Actual Pond Volumes (using average end method): Avg Incr. Incr. Cum. Main Bay Volume Elevation Area SF Area S Depth (FTC Vol CF Vol CF Pond Bottom 41 E30 2:168 Bottom Veg Shelf 15 33 5;03 3,600 4.33 15,588 15,588 Normal Pond 17 G0: :9 923; 7,478 1.67 12,487 28,075 Main Bay Volume = 28,075 CF Forebay Volume Elevation Area SF Area SF Depth (FT i Vol CF Vol CF Pond Bottom 11.00 ...::.:.:::: �— .0 Normal Pond 17.00r;;:;:>::;2 178D': 1,139 6.00 6,834 6,834 Forebay Volume = 6,834 CF Total Pond Volume = 34,909 CF Forebay Volume equates to 19.6 % of Total Volume Temp. Storage VolumeElevation A F Area (SF Depth (FT l VolCF Vol CF Normal Pond 17.00 12,003 Temp. Pond Level 1$ 37 1�#'$17 13,160 1.37 18,029 18,029 Temp. Pool Volume = 18,029 CF 1.0 Yr Storage Volume : Elevation Area SF Area SF Depth (ET_l Vol (CE Vol CF Temp Pond Level 18.37 14,317 Temp. Pond Level 194fi i618f' 15,249 1.09 16,695 16,695 Temp. Pool Volume = 00 Yr Storage VqjUme Temp Pond Level Temp. Pond Level Temp. Pool Volume 11. SUMMARY Pond Elevations: Top Berm (minimum) 100-Yr. Flood 10-Yr. Flood 1-inch Storage 16,695 CF vatio Area (SF Area SF t T VolC Vol (CF) 18.37 14,317 19 6t3: 1;6404'. 15,361 1.23 18,837 18,837 18,837 CF e a b Actual 9.04 20.04 M= 0.44 8.60 19.60 (emerg. weir elev) H100 = 1.23 8.46 19.46 H10 = 1.09 storage depth = 1.37 Permanent Pool pond depth = 6 Pond Bottom 12. WET DETENTION BASIN SUPPLEMENT Basin Bottom Elevation 11.00 Perm. Pool Elevation 17.00 Temp. Pool Elevation 18.37 Perm Pool Surface Area 12,003 SF Drainage Area 6.41 AC Impervious Area 4.83 AC Perm. Pool Volume 34,909 CF Temp Pool Volume 18,029 CF Forebay Volume 6,834 CF SAIDA 4.2713 Diameter of Orifice 2.00 Design Rainfall 1" 7.37 18.37 (primary weir elev) 6.00 17.00 (invert out elev) Stormwater Treatment & Erosion Control Narrative (Revised April 20, 2005) Bobby Morton Project Bobby R. Morton proposes to construct a commercial (retail/storage) development on a 9.95 acre lot located on NC 241US 258 (Richlands Hwy), just past Hickory Road, in the Jacksonville Township, Onslow County. The site is currently undeveloped. The project site is located approximately 0.11 miles from an UT of Blue Creek (SC;NSW) in the White Oak Basin. The proposed development activities are high density (percent impervious > 25 %); therefore, stormwater treatment facilities are required. The attached Stormwater Plan includes a 12,003 sf wet detention basin at the eastern side of the site. The pond is sized to accommodate 210,288 square feet of impervious area allocated as follows: Buildings Streets Parking Sidewalks Other (Dump. Pad) Reserve for Future Total Site Offsite Total 66,800 sf -0- 66,800 sf -0- -0- -0- 136,932 sf -0- 136,932 sf 1,435 sf -0- 1,435 sf 121 sf -0- 121 sf 5 000 sf -0- 5,000 sf 210,288 sf -0- 210,288 sf The proposed pond is sized for 90% TSS removal. The pond does not incorporate pretreatment, other than the forebay. The pond does not include a vegetated filter at the outlet. All stormwater emanating from new impervious surfaces that is generated on -site shall be collected and directed to the eastern side of the site by a system of sheet drainage, grassed swales and storm drainage pipes. The treatment system will require periodic maintenance. Maintenance frequency shall be dictated by pond depths. Pond depths shall be checked by the owner on a quarterly basis. When measured depths are less than 4.50' (for the main pond as well as the forebay), the pond shall be manually dewatered (pump) and accumulated sediment removed and properly disposed of. Site topography is gently sloping (0 — 5%) with the lowest elevations towards the southeasterly boundary of the tract. Soils are loamy sand/sandy loam. The entire area designated within "Clearing Limits" will be disturbed during initial construction, and will include grading for parking, swales and storm drainage. CHARLES F. RIGGS & ASSOCIATES, INC. 202 WARLICK STREET P.O. BOX 1570 JACKSONVILLE, NORTH CAROLINA 28541 Telephone (910) 455-0877 Facsimile: (910) 455-9033 riggsland@bizee.rr.com �C9TVEI] June 2, 2005 JUN 0 3 2005 Ms. Linda Lewis BY: Environmental Engineer Division of Water Quality Wilmington Regional Office State of North Carolina Department of Environment and Natural Resources 129 Cardinal Drive Extension Wilmington, North Carolina 28405 Re: Stormwater Application for Bobby R. Morton Jacksonville Township, Onslow County, North Carolina Stormwater Permit No. SW9050441 Dear Ms. Lewis: On behalf of Mr. Bobby R. Morton, Charles F. Riggs & Associates, and David K. Newsom, P.E. Crystal Coast Engineering, P.A., have enclosed the following for your review; (2) two copies "Drainage Area Supplement, (2) two sets of the of the Stormwater Management Permit Application Forms, with (1) one copy Wet Detention Basin Supplement, (2) two sets Design Calculations, (1) one copy Stormwater Treatment Narrative, (3) three sets of plans, and check # 2065 in the amount of $420.00, Respectfully,