Loading...
HomeMy WebLinkAboutSW8050308_COMPLIANCE_20190718STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW DOC TYPE ❑ CURRENT PERMIT ❑ APPROVED PLANS ❑ HISTORICAL FILE COMPLIANCE EVALUATION INSPECTION DOC DATE WYYMMDD I Compliance Inspection Report Permit: SW8050308 Effective:04128/05 Expiration: 04/28/19 Project: Bella Sera Villas at Vineyard Plantation Owner: White Partners, LLC County: New Hanover Adress: Futch Creek Rd Region: Wilmington City/State/Zip: Wilmington NC 28405 Contact Person: Stephen D Saieed Title: Phone: 910-509-1696 Directions to Project: Site is on south side of Futch Creek Road (SR1400), 3,500 feet east of it's intersection with Market Street (US 17). Type of Project: State Stormwater - HD - Infiltration Drain Areas: 1 - (Futch Creek) (03-06-24) { S&HQW) On -Site Representative(s): Related Permits: Inspection Date: 07/18/2019 Entry Time: 12:15PM Exit Time: 12:25PM Primary Inspector: Alida R Lewis Secondary Inspector(s): Phone: 910-796-7215 Reason for Inspection: Other Inspection Type: Transfer Renewal Permit Inspection Type: State Stormwater Facility Status: ❑ Compliant Not Compliant Question Areas: State Stormwater (See attachment summary) Page] 1 Permit: SW8050308 Owner - Project: White Partners, Li Inspection Date: 07/18/2019 Inspection Type Transfer Renewal Inspection Summary: Reason for Visit: Other The Division received a complaint from the residents of this project in January 2016 regarding the non-functioning infiltration basin. The project was inspected on January 25, 2016 and again on February 3, 2016 and it was determined that the infiltration basin was not functioning as designed, No response to the February 8, 2016 inspection letter was received, so the Division followed up with a second letter dated November 2, 2016. No response to the second letter was received and additional complaints from the residents were received, so the Division issued a Notice of Violation on August 16, 2017. An evaluation of the basin was performed and on August 14, 2018, a plan of action was finally submitted by White Partners, LLC that included a plan to restore the basin to design condition. The permittee performed the restoration work in April 2019. Due to the dry weather, the Division was not able to inspect the project for compliance until a sufficient amount of rain had fallen, which finally occured on July 13, 2019, On July 18, 2019, staff observed that the basin is holding water after receiving approximately 0.9 inches of rain on July 13, 2019 and only a trace of rain during the ensuing 5 days. The project is not in compliance and the permit cannot be transferred at this time. The permit expired on April 28. 2019 and has not been renewed. The permittee dissolved the corporate entity effective December 31, 2018. SW Measures Are the SW measures constructed as per the approved plans? Are the inlets located per the approved plans? Are the outlet structures located per the approved plans? Comment: Operation and Maintenance Are the SW measures being maintained and operated as per the permit requirements? Are the SW l3MP inspection and maintenance records complete and available for review or provided to DWQ upon request? Comment: Yes No NA NE M 000 ®❑❑❑ Yes No NA NE ■ ❑❑❑ ❑ ❑e❑ Other Permit Conditions Yes No NA NE Is the site compliant with other conditions of the permit? ❑ ®❑ ❑ Comment: 1. The infiltration basin is still not infiltrating, despite being restored and having relatively dry weather. 2. The permit expired on April 28. 2019 and has not been renewed. 3. The permittee dissolved thier corporate entity on December 31, 2018. 1 2 Compliance Inspection Report Permit: SW8050308 Effective:04/28/05 Expiration: 04/28/19 Project: Bella Sera Villas at Vineyard Plantation Owner: White Partners, LLC County: New Hanover Adress: Futch Creek Rd Region: Wilmington City/State/Zip: Wilmington NC 28405 Contact Person: Stephen D Saieed Title: Phone: 910-509-1696 Directions to Project: Site is on south side of Futch Creek Road (SR1400), 3,500 feet east of it's intersection with Markel Street (US 17). Type of Project: State Stormwater - HD - Infiltration Drain Areas: 1 - (Futch Creek) (03-06-24 } ( SA;HQW) On -Site Representative(s): Related Permits: Inspection Date: 07/18/2019 Entry Time: 12:15PM Exit Time: 12:25PM Primary Inspector: Alida R Lewis Secondary Inspector(s): Phone: 910-796-7215 Reason for Inspection: Other Inspection Type: Transfer Renewal Permit Inspection Type: State Stormwater Facility Status: ❑ Compliant 0 Not Compliant Question Areas: State Stormwater (See attachment summary) page: 1 Permit: SW60503DS Owner - Project: White Partners, LLC Inspection Date: 07/1812019 Inspection Type Transfer Renewal Reason for Visit: Other Inspection Summary: The Division received a complaint from the residents in January 2016 regarding the non-functioning infiltration basin. The project was inspected on January 25. 2016 and February 3, 2016 and it was determined that the infiltration basin was not functioning as designed. Having received no response to the February 8, 2016 inspection letter, the Division followed up with a second letter dated November 2, 2016. Having received no response to the second letter, and additional complaints from the residents, the Division issued a Notice of Violation on August 16, 2017. An evaluation of the basin was performed and on August 14, 2018, a plan of action was finally submitted by the consultant on behalf of White Partners, LLC that included a plan to restore the basin to design condition. The permittee performed the restoration work in April 2019. Due to the dry weather, the Division was not able to inspect the project for compliance until a sufficient amount of rain had fallen, which finally occured on July 13, 2019. On July 18, 2019, staff observed that the basin is holding water after receiving approximately 0.9 inches of rain on July 13, 2019 and only a trace of rain during the ensuing 5 days. The project is not in compliance and the permit cannot be transferred at this time. SW Measures Are the SW measures constructed as per the approved plans? Are the inlets located per the approved plans? Are the outlet structures located per the approved plans? Comment: Operation and Maintenance Are the SW measures being maintained and operated as per the permit requirements? Are the SW 8MP inspection and maintenance records complete and available for review or provided to DWQ upon request? Comment: Other Permit Conditions Is the site compliant with other conditions of the permit? Yes No NA NE ■ ❑❑❑ ■ ❑❑❑ s❑❑❑ Yes No NA NE E ❑ ❑ ❑ ❑ ❑ M ❑ Yes No NA NE ❑ ■❑❑ Comment: 1. The infiltration basin is still not infiltrating, despite being restored and having relatively dry weather. page: 2 Compliance Inspection Report Permit: SW8050308 Effective:04/28/05 Project: Bella Sera Villas at Vineyard Plantation Owner: White Partners, LLC County: New Hanover Region: Wilmington Expiration: 04/28/19 Adress: Futch Creek Rd City/State/Zip: Wilmington NC 28405 Contact Person: Stephen D Saieed Title: Phone: 910-509-1696 Directions to Project: Site is on south side of Futch Creek Road (SR1400), 3,500 feet east of it's intersection with Market Street (US 17), Type of Project: State Stormwater - HD - Infiltration Drain Areas: 1 - (Futch Creek) (03-06-24) ( SA;HQW) On -Site Representative(s): Related Permits: Inspection Date: 02103/2016 Entry Time: 02:30PM Primary Inspector: Alicia R Lewis Secondary Inspector(s): Reason for Inspection: Follow-up Permit Inspection Type: State Stormwater Facility Status: ❑ Compliant ® Not Compliant Question Areas: ® State Stormwater (See attachment summary) ,vGV- 00�7- X. C' ssq Exit Time: 02:35PM Phone: 910-796-7215 Inspection Type: Compliance Evaluation page: 1 Permit: SW8050308 Owner -Project: White Partners, LLC Inspection Date: 0210312016 Inspection Type Compliance Evaluation Reason for Visit: Follow-up Inspection Summary: The followup inspection to the January 25, 2016 inspection was to determine if the infiltration basin is drawing down within 5 days. It is not. The basin's infiltration capacity must be restored to design condition. Operation and Maintenance Yes No NA NE Are the SW measures being maintained and operated as per the permit requirements? ❑ ®❑ ❑ Are the 5W BMP inspection and maintenance records complete and available for review or provided to ❑ ❑ ❑ TWO upon request? Comment: 1. The infiltration basin BMP was full of water on January 25 _2016. The basin was still full of water at the followup inspection conducted 9 days later. The basin is reguired_to drawdown completely within 5 days. There has been only about a_quarter of an inch of rain since_ January 25 2016. 2. The infiltration capacity of the basin will need to be restored. The bottom of the basin has most likely been "blinded off' by the accumulated sediment which must now be removed. page: 2 Compliance Inspection Report Permit: SW8050308 Effective:04I28105 Project: Bella Sera Villas at Vineyard Plantation Owner: White Partners, LLC County: New Hanover Region: Wilmington Expiration: 04/28/19 Adress: Futch Creek Rd CitylStatelZip: Wilmington NC 28405 Contact Person: Stephen D Saieed Title: Phone: 910-509-1696 Directions to Project: Site is on south side of Futch Creek Road (SR1400), 3,500 feet east of it's intersection with Market Street (US 17). Type of Project: State Stormwater - HD - Infiltration Drain Areas: 1 - (Futch Creek) (03-06-24) { SA;HQW) On -Site Representative(s): Related Permits: Inspection Date: 01/25/2016 EntryTime: 01:40PM Primary Inspector: Alida R Lewis Secondary Inspector(s): Reason for Inspection: Other Permit inspection Type: State Stormwater Facility Status: ❑ Compliant ® Not Compliant Question Areas: ® State Stormwater (See attachment summary) Exit Time: 01:50PM Phone: 910-796-7215 Inspection Type: Compliance Evaluation page: 1 Permit: SW8050308 owner - Project: White Partners, LLC Inspection Dale: 01125/2016 Inspection Type Compliance Evaluation Reason for Visit: Other inspection Summary: The Division received a general question from a homeowner regarding the ability to modify the permit to allow the pond to retain a higher water level during periods of drought. The HOA doesn't own the permit, so they cannot propose to modify it. The pond could be lined with bentonite clay to inhibit infiltration, but all of the runoff from the site must drain into the infiltration basin first to be infiltrated. Only the excess design storm is routed to the pond. Several of the lots went from duplex lots to single family, but the permit was not modified to reflect this. File Review Yes No NA NE Is the permit active? ® ❑ ❑ ❑ Signed copy of the Engineers certification is in the file? ❑ ❑ ❑ Signed copy of the Operation & Maintenance Agreement is in the file? ® ❑ ❑ ❑ Copy of the recorded deed restrictions is in the file? ❑ ®❑ ❑ Comment: 1. The permittee has not submitted a copy of the recorded deed restrictions. Built Upon Area Yes No NA NE Is the site BUA constructed as per the permit and approval plans? ® ❑ ❑ ❑ Is the drainage area as per the permit and approved plans? ® ❑ ❑ ❑ is the BUA (as permitted) graded such that the runoff drains to the system? ❑ ❑ ❑ Comment: SW Measures Yes No NA NE Are the SW measures constructed as per the approved plans? ® ❑ ❑ ❑ Are the inlets located per the approved plans? ® ❑ ❑ ❑ Are the outlet structures located per the approved plans? ® ❑ ❑ ❑ Comment: Operation and Maintenance Yes No NA NE Are the SW measures being maintained and operated as per the permit requirements? ® ❑ ❑ ❑ Are the SW BMP inspection and maintenance records complete and available for review or provided to. ❑ ❑ ❑ DWQ upon request? Comment: 2. The infiltration_ basin was full, but it's only been 2 full days since the Blizzard of 2016 dumped about 2-3 inches of rain. The basin will be inspected again at the end of the week -to see if it is infiltrating within 5 days. •-_ ___.... _..,.._,._. ._..,_. __. _..._, .... ._. —, Other Permit Conditions Is the site compliant with other conditions of the permit? Yes No NA NE ❑ ®❑❑ Comment: 3. The permit has not been transferred to the HOA. 4. A couple of the lots were apparently switched from duplex lots to single family lots without a permit modification. page: 2 Lewis,Linda From: Lewis,Linda Sent: Thursday, July 18, 2019 4:10 PM To: Steven Beattie Cc: Phil Norris Subject: Bella Sera SW8 050308 I stopped by the site at lunch today and I observed several inches of standing water in the infiltration basin. I note that the area sustained slightly under one inch of rain on Saturday, July 13, 2019 with only a trace amount falling since then up to right now. It is doubtful that the basin will be dry by the end of today. The project cannot be called in compliance at this time, and the permit cannot be transferred to the HOA. I think you need to consider the possibility that the water level in the county's pond may be influencing the localized SHWT in the immediate vicinity of the infiltration basin and that the basin will never be able to infiltrate within 5 days if that turns out to be true. One option that is still available is to redesign the existing pond under the 2017 rules to accommodate the runoff from Bella Sera. I am sorry -- I had high hopes that this restoration would work. Linda Lewis, E.I. Environmental Engineer III Division of Energy, Mineral and Land Resources Department of Environmental Quality 910-796-7215 Office Iinda.Iewis(d,)ncdenr.gov Wilmington Regional Office 127 Cardinal Drive Extension Wilmington, NC 28405 r::• Nothing Compares--,, Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. ROY COOPER Governor MICHAEL S. REGAN Secretary S. DANIEL SMITH Director July 22, 2019 !NORTH CAROLIINA Environmental Quality White Partners, LLC Attn: Steven Beattie, DeWitt Carolinas 3301 Benson Drive, Suite 103 Raleigh, NC 27609 Subject: Notice of Inspection - Not Compliant / Request to Transfer Bella Sera Villas at Vineyard Plantation State Stormwater Management Permit No. SW8 050308 New Hanover County Dear Mr. Beattie: On July 18, 2019 staff of the Division of Energy, Mineral and Land Resources (DEMLR) conducted a follow-up inspection of Bella Sera Villas at Vineyard Plantation located off Futch Creek Road in New Hanover County, to determine the status of compliance with the State Stormwater Management Permit Number SW8 050308 issued on April 28, 2005. The permitted infiltration basin was supposedly restored to design condition in April 2019. The drought delayed the Division's ability to reinspect the project until now. It has been determined that the infiltration basin is still not in compliance with the terms and conditions of the permit or the stormwater rules. Please find a copy of the form entitled "Compliance Inspection Report" attached to this letter, which summarizes the findings of the recent inspection. As indicated in the attached inspection report, the following deficiencies must be resolved: 1. The maintained and restored infiltration basin is still not drawing down within 5 days as required by the stormwater rules. 2. The permit expired on April 28, 2019 and has not been renewed. Please submit a renewal application and fee to the Division. It will not be possible to transfer the permit until it is renewed. 3. The permittee dissolved the corporate entity, White Partners, LLC, effective December 31, 2018. The permittee remains responsible for maintaining, renewing and transferring the permit. Failure to provide the requested information, or to respond to this letter with a new plan of action, including a timeline to resolve the identified deficiencies, by August 22, 2019 are considered violations of the permit. If the requested information is not submitted to this office by the due date, then DEM LR staff will re -inspect the site and may issue a Notice of Violation. If any of you have any questions, please contact me at the Wilmington Regional Office, telephone number (910)-796-7215 or via email at Iinda.lewisC@ncdenr.go_v. Sincerely, Linda Lewis, E.I. Environmental Engineer III Enc: July 18, 2019 Compliance Inspection Report J� GDS\arl: G:\\\Stormwater\Permits & Projects\2005\050308 HD\2019 07 CEI_deficient 050308 JJJ cc: Phil Norris, P.E., Norris & Tunstall Bella Sera Villas at Vineyard Plantation Association, Inc. (PO Box 12051 Wilmington NC 28405) WiRO Stormwater Permit File ®� � North Carolina Department of Environmental Quality P DMsion of Energy. Mineral and Land Resources Wilmington Regional Office i 127 Cardinal Drive Extension I Wilmington, North Carolina 28405 Naar, Gwa�Na '�^"'"�o 0+4� WE 796.7215 e Compliance Inspection Report Permit: SW8050308 Effective:04/28/05 Expiration: 04/28/19 Project: Bella Sera Villas at Vineyard Plantation Owner: White Partners, LLC County: New Hanover Adress: Futch Creek Rd Region: Wilmington City]StatelZip: Wilmington NC 28405 Contact Person: Stephen D Saieed Title: Phone: 910-509-1696 Directions to Project: Site is on south side of Futch Creek Road (SR1400), 3,500 feet east of it's intersection with Market Street (US 17). Type of Project: State Stormwater - HI] - Infiltration Drain Areas: 1 - (Futch Creek) (03-06-24) ( SA;HQW) On -Site Representative(s)- Related Permits: Inspection Date: 07118/2019 Entry Time: 12:15PM Exit Time: 12:25PM Primary Inspector: Alida R Lewis Secondary Inspector(s):T/Y„fi/(J��r_ Phone: 910-796-7215 Reason for Inspection: Other Inspection Type: Transfer Renewal Permit Inspection Type: State Stormwater Facility Status: ❑ Compliant Not Compliant Question Areas: State Stormwater (See attachment summary) page: 1 Permit: SW8050308 Owner - Project: White Partners, LLC Inspection Data: 0711812019 Inspection Type Transfer Renewal Inspection Summary: Reason for Visit: Other The Division received a complaint from the residents of this project in January 2016 regarding the non-functioning infiltration basin. The project was inspected on January 25, 2016 and again on February 3, 2016 and it was determined that the infiltration basin was not functioning as designed. No response to the February 8, 2016 inspection letter was received, so the Division followed up with a second letter dated November 2, 2016. No response to the second letter was received and additional complaints from the residents were received, so the Division issued a Notice of Violation on August 16, 2017, An evaluation of the basin was performed and on August 14, 2018, a plan of action was finally submitted by White Partners, LLC that included a plan to restore the basin to design condition. The permittee perforrhed the restoration work in April 2019. Due to the dry weather, the Division was not able to inspect the project for compliance until a sufficient amount of rain had fallen, which finally occured on July 13, 2019. On July 18, 2019, staff observed that the basin is holding water after receiving approximately 0.9 inches of rain on July 13, 2019 and only a trace of rain during the ensuing 5 days. The project is not in compliance and the permit cannot be transferred at this time. The permit expired on April 28, 2019 and has not been renewed. The permittee dissolved the corporate entity effective December 31, 2018, 5W Measures Are the SW measures constructed as per the approved plans? Are the inlets located per the approved plans? Are the outlet structures located per the approved plans? Comment: Operation and Maintenance Are the SW measures being maintained and operated as per the permit requirements? Are the SW BMP inspection and maintenance records complete and available for review or provided to DWQ upon request? Comment: Other Permit Conditions Is the site compliant with other conditions of the permit? Yes No NA NE ® ❑ ❑ ❑ ■ ❑❑❑ Yes No NA NE ■ ❑❑❑ ❑ ❑ M ❑ Yes No NA NE ❑ ■❑❑ Comments 1. The infiltration basin is still not infiltrating, despite being restored and having relatively dry weather. 2. The permit expired on April 28, 2019 and has not been renewed. 3. The permittee dissolved thier corporate entity on December 31, 2018. page 2 NOV-22-04 16:42 FROM:S&ME WILMINGTON I D : `3 1 07999956 PAGE 1/6 Saieed Construction Systems 1135 Military Cutoff Road, Suite 201 Wi4xAngton, North Carolina 28405 Attention: Mr. Gil Simmers Novelxmber 22, 2004 Reference: Double Ring Infiltrometer Testing Bella Sera Futch Cheek Road Porters Neck, North Carolina Job No. 1063-04-590 Dear Mt. Simmers: RECEIVED MAR 1 1 2005 DWQ DROJ # In accordance with S&ME Proposal 395-04 dated October 2I, 2004, ME personnel have recently conducted double -ring infi.ltrometer testing of the surficial soils at the subject site at the approximate locations shown in Figure 1. Specifically, our representatives perfonned the following work items on November 9 and 19, 2004: ` Advanced one hand-augered boring near each infiltrometer test location in order to visually classify the in -place soils. A Mansell Soil CoIor Chart was used to define the hue and chrorna of the recovered soil samples. 2. Conducted three double -ring infiltrometer tests at a depth of approximately 4 feet below the existing ground surface. This testing was conducted in general accordance with American Society for Testing and Materials (ASTM) procedure D-3385 entitled, "Infiltration Rate of SoiIs in Field Using Double - Ring Infnitrometer". Based on our field classifications of the excavated soils at the band-augered boring locations, the in - place soils consist of sands with, varying amounts of silt or clay. Sandy soils extended to the completed boring depth of 96 inches below the existing ground surface. No water was encountered in the boreholes. The site water level will fluctuate with climatic and seasonal conditions, however, and may be higher or lower at other dazes of the year. It is our opinion that the depth to the seasonal high water table exceeds slat feet below the existing ground surface. I 58ME, Inc. ; (970) 799.99AS j 6409 Amsterdam Way, Building B3 (910) 799-9958 fax i V0Imington, North CClrJlna 28405 I ww r�s r Ccn :.:am N,OV-22-04 16:43 1=ROM:S&ME WILMINGTON Ip:9197999SSe PAGE 2/6 Saieed Construction Systems S&ME Job Number 1063-04-590 Date Page Two The average infiltration rate at Location B-1 was approximately 1.5 inches per hour. At Location B-2, the average infiltration rate was approximately 1.4 inches per hour. The average infiltration rate at Location B-3 was approximately 0.4 inch per hour. A. summary of the field test results is presented in Tables 1, 2, and 3. S&ME appreciates the opportunity to provide our services during this phase of the project_ Should you have any questions after reviewing this letter, or if we can be of additional assistance, please do not hesitate to contact us at your convenience. Sincerely, S&ME, INC. C. Richard Connell, II Senior Engineering Technician Michael W. Behen, P.L. Senior Geotechrlical Engineer CRC:MWBrjns Attart«ns Fax: Norris, Kuske.& T unstall Consulting Engineers, Mr. Larry Sneeden, P.E. IIOV-22-04 16:43 FROM;S&ME WILMINGTON ID=9107999950 PAGE 3/6 TABLE I Double Rin- Infiltrometer Testing Bella Sera Futch Creek Road New Hanover County, North Carolina Job Number 1063-04-590 Location: 13-1 Date of Test: November 19, 2004 Depth of Test Below Site Grade: 4 feet Depth of Water in Rings: 4 4iches Inner Diameter of Inner Ring: 11 %2 inches Inner Diameter of Outer Ring: 22%2 inches Depth to Water: No water was encountered to depth investigated. Average Infiltration Rate: 1.5 inches per hour Depth Inches Hue Value/Chroma 0-18 2.5 Y 5/2 18-48 2.5 Y 7/2 48-58 2.5 Y 6/4 58-75 2.5 Y 514 75-84 2.5 Y 6/3 84-96 2.5 Y 616 SOIL PROFILE Soil Description Grayish Brown Fine to Medium SAND - Trace of Silt Light Gray Fine to Medium SAND - Trace of Silt Light Yellowish Brown Fine to Medium SAND - Trace of Clay Light Olive Brown Fine to Medium SAND - Some Clay Light Yellowish Brown Fine to Medium SAND - Trace of Clay Olive Yellow Fine to Medium SAND - Trace of Silt/Clay NOV-22-04 16:43 FROM:S&ME WILMINGTON ID=SIO7999958 PAGE 4/6 TABLE 2 Double Ring InfiItrometer Testing Bella Sera F'utch Creek Road New Hanover County, North Carolina Job Number 1063-04-590 Location: 18-2 Date of Test: November 19, 2004 Depth of Test Below Site Grade: 4 feet Depth of Water in Rings: 4 inches Inner Diameter of Inner Ring: 113/4 inches Inner Diameter of Outer Ring: 22'/2 inches Depth to Water: No water was encountered to depth investigated. Average Infiltration hate; 1.4 inches per hour Depth Inches Hue 'Value/Chroma 0-6 2.5 Y 5/2 6-46 2.5 Y 5/4 46-60 2.5 Y 6/4 60-96 2.5 Y 7/2 SOIL PROFILE Soil Description Grayish Brown Fine to Medium SAND - Trace of Silt and Organics Light Olive Broom Clayey Fine to Medium SAND Light YelloMsh Brown Fine to Medium SAND - Trace of Clay Light Gray Fide to Medium SAND NOV-22-04 16:43 FROM:5&ME WILMINGTON ID:9107999958 PAGE 5/G TABLE 3 Double Ring Infxltrometer Testing Bella Sera Futch Creek Road New Hanover County, North Carolina Job Number 1063-04-590 Location: B-3 Date -of Test: November 19, 2004 Depth of Test Below Site Grade: 4 feet Depth of Water in Rings: 4 inches Inner Diameter of Inner king: 113/4 inches Inner Diameter of Outer Ring: 22% inches Depth to Water: No water was encountered to depth investigated. Average Infiltration Rate. 0.4 inch per hour Depth (Inches) Hue Value/Chroma 0-13 2.5 Y 6/2 13-40 2.5 Y 6/3 40-60 2.5 Y 5/4 60-72 2.5 Y 6/6 72-96 2.5 Y 6/3 SOIL PROFILE Soil Description Light Brownish Gray Fine to Medium SAND - Trace of Silt Light Yellowish Brown Fine to Medium SAND - Trace of Silt Light Olive Bro Am Clayey Fine to Medium SAND Olive Yellow Fine to Medium SAND - Trace of Silt Light Yellowish Brown Fine to Medium SAND - Trace of Silt VINEYARD NORM MnN V `-F�1'FfEldc ROTA _ I lam W. r {' mOaLR Q Lar 47 I — •• -� - la M I Crrll A[A 11 LA7 W. i ,,fW LM 1 COO,fSM RM Q 1 r N ----- 4 I r1w. I- I I LAMM IA7J2I _ _ - _ _ _ _ _ lR w _ i ,u fl I Ian lAr 07tw al IDf 1p �� ��jj w n 771 I,A�A sr. Il� ,117a s^ 1 W. I,aW rT711/� I1�00 IF ' ^u.4C I� -- 1 tar„ i 1 i i i i li i i u f 1 I.*W V. i 1 I l � lra„o 7n 11i.1�i>7 QS O UN a• i rA161 l 00 S+. t i 1 ( 1 1 1 I 1a�I II I � I L I •` P i TL.x:A aUd' a 1 = I 14 K. lC7 14 LD[ ri I^t %• 11�/K. { {GT 1r i La►,t✓?f 1t I 11JCC IIH f40W�� YY 11-4 ltpo C/. 11a ~ice w w VVEMD SCUM Note: Site plan drawing provided to S&NIE'by Saiead Construction Company personnel. LEGEND Q Approximate, B-1 Test Location SCALE. NOT TO SCALE flNGINEERIKG - 7ESTINO ENVIRONMENTALSERVICEB SITE PLAN BELLA SERA FLITCH CREEK ROAD NEW HANOVER COUNTY, NC FIGURE NUMBER CHECKED BY: MWBICRC DRAWN BY: JNS DATE: 11-9-04 JOB NUMBER: 1663-04-690 (fl Ln a) m m I40V—Oa-04 16:11 FROM=S&ME WILMINGTON ID=91070999Sa PAGE 1/5 Fax TransmittalSM ENGINEERING - TESTING ENVIRONMENTAL SEVICE5 Date: 11-9-04 ww-w.smeinc.dom To: Larry- Sneeden From: Michael 13ehen Company: Phone: (910) 799-9945 Fax: Fax: (910) 799-9958 Re: Bella Sera Email: # pages: 5 (including cover sheet) Comments: Attached are the logs describing the subsurface conditions eacountered at the 7 boring locations and a site plan drawing showing the approximated boring locations_ I wanted you to have an opportunity to look over these findings before we proceeded v ith the infiltrometeir tests. Let me blow if you want us to proceed with the inliiltrometer testing work as originally discussed, and we will take care of it. 6409 Amsterdam Way This cover sheet and the documents accompanying this fax transmission contain information from S&\, 4F-, Inc- which is $uildingS3 confidential and Iopaily privileged. Tha information is tntcnded only for use of the individual or entity named on this Wilmington, NC 7.8405 transmission sheet. If you are not the intended recipient, you are hereby notified that any &xIcsure, copying, (910) 799-9945 distribution or the taking of arty action in reliance on that documents is strictly prohibited. (910) 799-9958 fax ScP N E SFG-001 (Rcv, 7W) NOV-09-04 1G:11 FROM:S&ME WILMINGTON ID=9107999958 PAGE 2/5 TABLE I Hand Auger Borings MunselI Soil Descriptions Bella Sera Futch Creek Road New Hanover County, North Carolina Job Number 1063-04-590 Depth Location(Inches) Hue Value/Chroma Soil Description A-1 0-14 2.5 Y 513 Light Olive Brown Fine to Medium SAND - Trace of Silt 14-28 2.5 Y 6/3 Light Yellowish Brown Fine to Medium SAND - Trace of Silt 28-48 2.5 Y 4/3 Dark Gray Fine to Medium SAND - Trace of Silt 48-60 2.5 Y 613 Light Yellowish Brown Fine to Medium SAND - Trace of Silt 60-86 2.5 Y 6/2 Light Brownish Gray Fine to Medium SAND - Trace of Silt/Clay 86-96 2.5 Y 6/4 Light Yellowish Brown Fine to Medium SAND - Trace of Clay No water was encountered to depth investigated. A-2 0-13 2.5 Y 5/2 13-56 2.5 Y 6/3 56-77 2.5 Y 5/4 77-82 2.5 Y 7/3 82-96 2.5 Y 7/2 No water was encountered to depth investigated. Grayish Brown Fine to Medium SAND - Trace of Silt and Organics Light Yellowish Brown Fine to Medium SAND - Trace of Silt Light Olive Brown Fine to Medium SAND - Some Clay Pale Yellow Fine to Medium SAND - Trace of Clay Light Gray Fine to Medium SAND NOv-09-04 15:11 FROM:S&ME WILMINGTON ID:9107999958 PAGE 3/5 Table 1 (Continued) Job Number 1063-04-590 Page Two Depth Location Inches Hue Value/Chroma Soil Description A-3 0-12 2.5 Y 6/2 Light Brownish Gray Fine to Medium SAND - Truce of Silt and Organics 12-26 2.5 Y 7/2 Light Gray Fine to Medium SAND - Trace of Silt 26-36 2.5 Y 7/2 Light Gray Fine to Medium SAND - Trace of Clay 36-48 2.5 Y 7/2 Light Gray Fine to Medium SAND - Trace of Salt 48-66 2.5 Y 6/4 Light Yellowish Brown Fine to Medium SAND - Some Clay 66-72 2.5 Y 6/6 Olive Yellow Fine to Medium SAND - Trace of Clay 72-96 2.5 Y 6/6 Olive Yellow Fine to Medium SAND - Trace of Silt No water was encountered to depth investigated. A-4 0-14 2.5 Y 5/2 14-24 .2.5 Y 6/3 24-50 2.5 Y 7/1 50-70 2.5 Y 6/2 70-86 2.5 Y 7/2 86-96 2.5 Y 5/4 No water was encountered to depth investigated. Grayish Brown Fine to Medium SAND - Trace of Silt Light Yellowish Brown Fine to Medium SAND - Trace of Silt Light Gray Fine to Medium SAND - Trace of Silt Light Brownish Gray Fine to Medium SAND - Trace of Clay Light Gray Fine to Medium SAND - Trace of Silt Light Olive Brown Fine to Medium SAND - Trace of Clay NOV-09-04 1G:12 FROM=S&ME WILMINGTON ID;9107999950 PAGE 4/5 `fable 1 (Continued) Job Number 1063-04-590 Page Three Depth Location aches Hue Value/Chroma Soil Description B-1 0-18 2.5'Y 5/2 Grayish Brown Fine to Medium SAND - Trace of Silt 18-48 2.5 Y 7/2 Light Gray Fine to Medium SAND - Trace of Silt 48-58 2.5 Y 6/4 Light Yellowish Brown Fine to Medium SAND - Trace of Clay 58-75 2.5 Y 5/4 Light Olive Brown. Fine to Medium SAND - Some Clay 75-84 2,5 Y 6/3 Light Yellowish Brown Fine to Medium SAND - Trace of Clay 84-96 25 Y 6/6 Olive Yellow Fine to Medium SAND - Trace of Silt/Clay No water was encountered to depth investigated. B-2 0-6 2.5 Y 5/2 6-46 2.5 Y 5/4 46-60 2.5 Y 6/4 60-96 2.5 Y 7/2 No water was encountered to depth investigated. B-3 0-13 2.5 Y 6/2 13-40 2.5 Y 6/3 40-60 2.5 Y 5/4 60-72 2.5 Y 616 72-96 2.5 Y 6/3 No crater was encountered to depth investigated. Grayish Brown Fine to Medium SAND - Trace of Silt and Organics Light Olive Brown Clayey Fine to Medium SAND Light Yellowish Brown Fine to Medium SAND - Trace of Clay Light Gray Fine to Medium SAND Light Brownish Gray Fine to Medium SAND - Trace of Silt Light Yellowish Brown Fine to Medium SAND - Trace of Silt Light Olive Brown Clayey Fine to Medium SAND Olive Yellow Fine to Medium SAND - Trace of Silt Light Yellowish Brown Fine to Medium SAND - Trace of Silt �- I I te�sair. VINEYARD NORM J - - r I -3 I IN. IF. as NINA i Q W. I - 1, 1�00 lF. I IQ70t114fle U) Isis I MANf.l ^ 111 Am W. LX 1 '�rI tlia tr'11APM OF. IAMr. i 11r 11.��. It1�Rwr• I I I I 1 1 i f,AW W. A 1 1 1 i 1 I A- 1 1 t INA" t-1 t kv m A I 1 1 I I or. 1 1 I 1, W . y s1=it r VINefARD SIOM L Note: Site plan drawing provided to S&ME by Saieed Construction Company personnel. LEGEND SCALE: NOT TO SCALE SITE PLAN FIGURE Q Approximate CHECKED BY; MWBICRC eo BELLA SERA NUMBER A-1 Test Location FLITCH CREEK ROAD DRAWN BY: JNS IF= NEW HANOVER COUNTY NC O Approximate ENGINEEAIKG TESTING 1 13.1 Test Location DATE: 11.9.04 ENVIRONMENTAL SERVICES JOB NUMBER: 9063-04-590 N 11 70 0 3 Cf1 IP 3 m v- r 3 z 0 z m m to co tD in In Ul INFILTRATION BASIN ANALYSIS PROJECT NUMBER: 050308.mar05 PROJECT NAME: Bella Serra at Futch Creek DRAINAGE BASIN: Cape Fear RECEIVING STREAM: Futch Creek Index No.: SITE AREA 21.47 acres IMPERVIOUS AREA CALCULATION BUILDINGS PARKING/ASPHALT CONCRETE OTHER TOTAL % IMPERVIOUS, 1= 313% ELEVATION OF SEASONAL HIGH WATER TABLE REPORTED INFILTRATION RATE SURFACE AREAS AND ELEVATIONS FILENAME: S:IWQSIINBASIN1050308.mar05.WK1 DATE: 15-Mar-05 REVIEWER: L. Lewis CLASS: SA If ORW, is site within the 575' AEC? DRAINAGE AREA: 935400 SF Rational C 120600 0.9 143900 0.9 28400 0.9 Place a " 1" here if Rational RV= .05+.009 (1) _ 5jFEET MSL 1 1'4 INCHEwS/HOUR or 0.000032 FPS Elev. (ft) Area, sq ft Inc. Volume Acc. Volume BOTTOM 19 11800 20 15000 13400 13400 21 18400 16700 30100 TOP 22 21800 20100 50200 VOLUME 1 DEPTH 1 DRAWDOWN CALCULATION DESIGN STORM, INCHES DESIGN VOLUME TOTAL VOLUME AVAILABLE STORAGE MET AT ELEVATION TIME TO DRAWDOWN 25 YEAR 24 HOUR STORM NIA Intensity, i = .33 inches 1 hour Qr=CiA= Qp through the bottom of the basin= 10 YEAR 10 MIN HIGH INTENSITY EVENT Intensity, i = 6.3 inches / hour Volume for 10 yr. 10 min. event = 49014. CUBIC FEET ;502D0 CUBIC FEET 21 94 FEET HOURS MUST BE <120 2.97 CFS 0.38 CFS Must be > Or 34026.07 CIF < 50200 CIF COMMENTS Volume and drawdown are (not) within Design Requirements. . 5�" 10 4 .c Av - 4-Y." rk 4 i Pr, A 4 ljX Z7 V_. M a vv, COASTAL CAROLINA 1301a sera suh(livision �RESOURCE GROU w Infiltration Hasin Location Map w,•F '� /u A! �y° _ 't`• +� } A - -.E 4 � h y, 4 f tt C L +i C' r i, � t � y r .i � ' � � i 1 r. ! E ., x � ..�r� •+� ��"''•".�J ��- �•�y' 4 �� 17�� w �x "s�i � 's 'Y'm r �e "r r r � YsSLri.��, (� ix G7 J�, °% n r2 w"' 4.'i. •G�i� °..M .'+"' �i � e � ,t _ ,.,�,.'�-�I^ ice,., _r..ne^•.�'•^:— •a ...px�n. ,ray. '", p s�At.: s�•�; 3�e }�Sy,�,��"�i .:'""� _ 1 ^ o-:P.` ` _. t {,. - IF k T _, � `��('�•rj_�� -.. _'r�- � .. „� + .y. P 4 q =. �G �F � 4 h^,�;,q r� r �x :Y •'P f i-3s i 3'. h i'.�.a,s:r� �....t y a �. - aryl' a 'r T. �►''s}� L.y} s ,.4 K1' " , t V .rrr� � �'3�":,}i � �, a aR�� r�yy r ti a. � i� a + � .y „� •'� } - ; • �aky •i r ; 4„ �ilf5 i `� a x"t '•ma's, ..+ '3 �: F"x.' •'' a. t'� � J� j Y +��c e G # t k'" ,'�F''�°-,�yw•.��: 1 �• dt f r " € ..-4•q. till t+ s 21, �yt4-1yL,,�' �:YE , � ,l'.� ,! avW} � ,rL,�' ks �i.l� t,Ya� U tsar', �a ,�`� �;•,ti' i�a .} ��.C'p�p�i4' �•. _ ..cc ""� '.�y"FF'iv k '..+ ;.. ,rye -!� ' v 1•r r.!'-�„r ry��''r �`„".,L+^--•�.,.x.....�-..+,•e•': * _ C "� i� rfi '�"�%".' "' •U .s i `- _ 1 �`.�r,•9 4r C� - " g,tiLp ( # , t;'' ...FR+�•v r� 'a T 3•i- � `' r � �WtZ/�r �,,ra ��,t[ � 7 L�'iT, •� ��r.• d -%s'. s{ (,.,"• •-4. . y�yo r �y i V, i r /r r '•'f.W. <, � T 2r w a - � `iaff7�we'+yr 'yg.a 1 n�it'r �NqQ.._�,�'• }a�' 1 - wh �,.+{Vk A a4 i % a e ?rN rr MSS F t ter Ar� to p :'v ell fir T .aa r "+ r� rJ •5y �. „� a • ,�,Cy 3t4'j =1wI Gr£.�wf1 u r : p -•� I - �.-': u y �c ;l4•re�T r '1 r{ S 2 R•�t 1'a,�,( lle.;t a 1 [ ,j}.a) T 1{„ ..r �& s^4 5 1� dpt€ y�2 r.�,' 4';.�� y 7' s., i 1,7n Rr'r, r< {� F i ✓';.- (.rw t �� �, q, `wi . . ' rc i -"i '' i! �� " x a. � r t[ � S =•`}'r ? 5 �q i f .r,R;, S"r j R ( .�p i� 's__v,,,,..gg-t- rIP Lewis,Linda From: Sent: To: Cc: Subject: Attachments: Messrs. Beattie and Daniels: Lewis,bnda Tuesday, January 16, 2018 8:54 AM 'Steven Beattie'; Everett Daniels 'Kin Liversidge' FW: Bella Sera Villas infiltration pond bella 1500.pdf, HOA Transfer Form_F.PDF Please respond to this email with a status report and a new plan of action. Per your September 15, 2017 email to the Division, the self-imposed December 1, 2017 deadline has passed and nothing has been submitted to the Division, as was promised. You still need to provide the following information: 1. A plan of action to restore the infiltration basin to design condition; 2. The remaining documents to transfer the permit, i.e., verification of BUA per lot, recorded plats and a copy of the recorded deed restrictions; I A completed permit update form to change your mailing address. Please note that this will be the last communication you receive from the Division before the transfer application is returned as incomplete and enforcement action is initiated. You must provide the requested information by February 16, 2018. Linda Lewis, E.I. Environmental Engineer III Division of Energy, Mineral and Land Resources Department of Environmental Quality 910-796-7215 Office lind2.lewis(a7ncdenr.gov Wilmington Regional Office 127 Cardinal Drive Extension Wilmington, NC 28405 Nothing Compares.. Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Steven Beattie (mailto:Steven.Beattie @dewittcarolinas.comi. Sent: Friday, September 15, 2017 9:55 AM To: Lewis,Linda <linda.lewis@ncdenr.gov> Cc: Everett Daniels <Everett.Daniels@dewittcarolinas.com> Subject: Bella Sera Villas Linda, Good morning. This is in response to the DENR violation received for Bella Sera Villas, 1. Failure to Operate and Maintain the Stormwater System: Response: The cause for malfunction has been investigating, the infiltration pond has been clogged due to vegetation such as alligator weed. The solution has been quoted. See attached. Remedy to malfunction of infiltration pond will be released no later than December I". The timeframe is to allow for adequate coordination with the HOA if needed. 2. Failure to receive prior approval for changes to the approved plan, Response: Exhibits are currently being prepared to display current impervious area of each lot is under the approved threshold shown in recorded plats and HOA does. This exhibit will be provided no later than December 1" 3. & 4. Failure to notify the Division of a change of ownership. Failure to notify the Division of a change of mailing address. Response: This form has been filled out and will be executed once the BMP is in compliance, Attached. Steven Beattie Director of Pre -Development 3301 Benson Drive Suite 103 Raleigh, NC 27609 Mobile 910.690.8140 1 Direct 919,277.7966 1 Main 919,863.1000 2 ` Lewis,Linda From: Lewis,Linda Sent: Thursday, October 12, 2017 4:25 PM To: 'david riggs' Subject: O&M agreement for Bella Sera SW8 050308 Attachments: 050308.pdf Mr. Riggs Here is the 0&M agreement that was originally approved with the permit. Once the HOA becomes the permittee of record, you will be following these requirements to operate and maintain the infiltration basin. I'm sure the HOA will do a much better job than the developer did. Linda Your message is ready to be sent with the following file or link attachments: 050308 Note: To protect against computer viruses, e-mail programs may prevent sending or receiving certain types of file attachments. Check your e-mail security settings to determine how attachments are handled. 1. Lewis,Linda From: Lewis,Linda Sent: Thursday, October 12, 2017 11:58 AM To: 'david riggs' Subject: FW: Bella Sera Villas Attachments: infiltration pond bella 1500.pdf, HOA Transfer Form_F.PDF Mr. Riggs: Here is the September 15, 2017 email from Steven Beattie with DeWitt Carolinas. It does mention a December 1, 2017 deadline to address the issues, Please note that I responded to that email on the same day to advise them that the attached transfer form they had filled out was not the correct form. I did not receive any response to my reply email. I'll scan and send the current O&M document to you separately. Linda From: Steven Beattie [mailto:Steven.Beattie @dewittcarolinas.comI Sent: Friday, September 15, 2017 9:55 AM To: Lewis,Linda <hnda.lewis@ncdenr.gov> Cc: Everett Daniels <Everett.Daniels@dewittcarolinas.com> Subject: Bella Sera Villas Linda, Good morning. This is in response to the DENR violation received for Bella Sera Villas. 1. Failure to Operate and Maintain the Stormwater System: Response: The cause for malfunction has been investigating, the infiltration pond has been clogged due to vegetation such as alligator weed. The solution has been quoted. See attached. Remedy to malfunction of infiltration pond will be released no later than December 1", The timeframe is to allow for adequate coordination with the HOA if needed. 2. Failure to receive prior approval for changes to the approved plan. Response: Exhibits are currently being prepared to display current impervious area of each lot is under the approved threshold shown in recorded plats and HOA dots. This exhibit wiH be provided no later than December 1" 3. & 4. Failure to notify the Division of a change of ownership. Failure to notify the Division of a change of mailing address. Response: This form has been filled out and will be executed once the BMP is in compliance, Attached. Steven Beattie Director of Pre -Development 3301 Benson Drive Suite 103 Raleigh, NC 27609 Mobile 910.690.8140 1 Direct 919.277.7966 1 Main 919.863.1000