HomeMy WebLinkAboutSW8050303_COMPLIANCE_20050305STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW �2 DOC TYPE ❑ CURRENT PERMIT ❑ APPROVED PLANS ❑ HISTORICAL FILE P,�COMPLIANCE EVALUATION INSPECTION DOC DATE YYYYMMDD WET DETENTION POND ANALYSIS FILE NAME: S:IWQSIPOND1050303.mar05.WK1 PROJECT #: SW8 050303.mar05 REVIEWER: PROJECT NAME: Zaxby's Restaurant Gordon Road DATE: 02-Mar-05 Receiving Stream: U1 Smith Creek. Class: C Sw Drainage Basin: Cape ;~ear Index No. Site Area 1.32 acres Drainage Area 576Fi00 square feet Area in Acres 1.32 IMPERVIOUS AREAS Buildings Parking SW Future TOTAL SURFACE AREA CALCULATION IMPERVIOUS 60.00% Des. Depth 3.5 TSS: 90 Rational C 3150.00 square feet 27600.00 square feet 2650.00 square feet 1212.00 square feet square feet square feet square feet ;A812.`00ill square feet Rational Cc= 0.08 SAIDA Ratio 6.00% Req. SA 3461 sf Prov. SA 28 sf VOLUME CALCULATION * place a "1" in the box if Rational is used Rational ?* Des. Storm 1'J0' inches Rv= 0.590 Bottom 40.25 msl Perm. Pool f 43 5.; msl Design Pool 44.25 msl Storage met @elev 44.16 msl Req. Volume r36', cf Vol. Prov. at DP ` !345.a.�` cf ORIFICE CALCULATION Avg. Head = Flow Q2, cfs Flow Q5, cfs No. of Orifices Diameter, inches Drawdown = C: 3.296190476 L= FOREBAY Perm. Pool Volume= Req. Forebay Volume= 0 Provided Volume= Percent=IaIV.Ol ' Elevation Area Inc. Vol. Acc. Vol. 43.75 6258.00 0.00 44.25 7555.00 3453.25 3453.25 Q2 Area = 1.03 sq. Q5 Area = 0.41 sq. Orifice Area 0.79 sq. Q= 0.013 cfs in x C Surface Area @DP = Falling Head Drawdown = -0.046 COMMENTS Surface Area , Volume and Orifice are within Design Guidelines inches inches inches LLLE in 7555 sq. ft. 4.3 days Zcxa.S Date Design Sheet NORRIS, KUSKE &TUNSTALL 902 Market St. O } 5CONSULTING ENGINEERS, INC. Wilmington, N.C.28401-4733 Of l Check Job 7an'1w��j� e:ForA r r� Job No. 4 C4- t-vC, CID- 60e1-90.v /�o/�.a 05DZS 7 �<<���rrrrrrrr�r ••C A ROfe.� " �� � ,•''�ESS1�' �, ►�4 v&I A ---3 0 ' C. e5t—l-' 5%1 ' g SF 4:�V' c-4i N (ow 3� / 5 a 5 F is F- 21 50 s),-- lc�lmai.g:-7 -T-v77e--- /►nP = �3C/�(o1Z 5F 6-71 (eE£ b 5P /) Z I Z 5F -- �c6 Co 1 Z s F &d CQ pia �a 4 F-o go 7-55 A*knovldl, G E V3.7 5 �f ZFr Naem fH POOL 4�t-�-/3 Z5 $ 5 F r ` 65' 5 t lv�Zs S SF il �l- r Qe—{ rlG6 PO r& I& — 45 OPVY l O-w J 2 3rZ p, DD9G/ RECEIVED MAR 0 3 2005 nw@ PRQJ # ' Date Design �, NORRIS, KUSKE &TUNSTALL CONSULTING ENGINEERS. INC. Check Job For 902 Market St. Sheet Wilmington, N.C.28401-4733 Of Job No. 5 - J!�, 00-3 75 Frz ' 53 Z_ FT-3 15/ / Z,1C-,0 f"T 3 3 Date Design A' NORRIS, KUSKE &TUNSTALL 902 Market St. Sheet CONSULTING ENGINEERS, INC. Wilmington, N.C.28401-4733 Of / Check Job For Job N�Co.. Q �v CGS REEvE IV E D pROJ # / fo Z/ .4t-- � Z v (o MAR 0 3 Z005 DWQ P7- 3 /ZCv-3 l o F—Tr 3 f ZCa r--T 3 / Vj Zb3 F-q--3 3 d- -� Z,(& - 7� NUT 4 ((SUS State Stormwater Management Systems Permit No. SW8 050303 Zaxby's Restaurant @Gordon Road Stormwater Permit No. SW 8 050303 New Hanover County Designer's Certification IJA4 Qi-P NHS , as a duly registered n t.- I in the State of North taeolina, having been authorized to observe (periodically .S=e} the construction of the project, (Project) for 11rGrI I" Qw&L-,omJ (Project Owner) hereby state that, to the best of my abilities, due care and diligence was used in the observation of the project construction such that the construction was observed to be built within substantial compliance and intent of the approved plans and specifications. The checklist of items on page 2 of this form is included in the Certification. Noted deviations from approved plans and specification: Signature Reg Date SEAT_ cc: Scott Lindstrom / Iron -Horse Development Page 6 of 7 r- State Stormwater Management Systems Permit No. SW8 050303 Certification Requirements: The drainage area to the system contains approximately the permitted acreage. The drainage area to the system contains no more than the permitted amount of built -upon area. All the built -upon area associated with the project is graded such that the runoff drains to the system. L5.4. All roof drains are located such that the runoff is directed into the system. e outlet/bypass structure elevations are per the approved plan. The outlet structure is located per the approved plans. 7. Trash rack is provided on the outlet/bypass structure. All slopes are grassed with permanent vegetation. 9. Vegetated slopes are no steeper than 3:1. lets are located per the approved plans and do not cause short- circuiting of the system. _�>�permitted amounts of surface area and/or volume have been _provided. 2. equired drawdown devices are correctly sized per the approved plans. 3. required design depths are provided. 4. All required parts of the system are provided, such as a vegetated shelf, and a forebay. 5. The required system dimensions are provided per the approved plans. cc: NCDENR-DWQ Regional Office Tony Roberts, New Hanover County Building Inspections Page 7 of 7