Loading...
HomeMy WebLinkAboutSW8040809_COMPLIANCE_20040622STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW DOC TYPE ❑ CURRENT PERMIT' ❑ APPROVED PLANS ❑ HISTORICAL FILE COMPLIANCE EVALUATION INSPECTION DOC DATE (o�� YYYYMMDD ._.:'..-STORMWATER=DIVISION RESCISSIONS PERMIT NO. CODING -SHEET...., ._..:.......:..:...:.-._.,.,.._ ._:.._.�s._.:_�-.......:_ - . DOC TYPE E ❑ COMPLETE FILE- HISTORICAL DATE OF ❑ RESCISSION YYYYMMDD June 22, 2004 BMS Architects, PC Post Office Box 3667 Wilmington, North Carolina 28406 Attention: Mr. Bruce Bowman, AIA Reference: Double Ring Infiltrometer Testing Operating Room Sterile Storage Addition Cape Fear Memorial Hospital Wrightsville Avenue Wilmington, North Carolina Job No. 1063-04-305 Dear Mr. Bowman: As requested, S&ME personnel have recently conducted double -ring infiltrometer testing of the surficial soils at the subject site at the approximate location shown in Figure 1. Specifically, our representative performed the following work items on June 18, 2004: Advanced one hand-augered boring near the infiltrometer test location in order to visually classify the in -place soils. A Munsell Soil Color Chart was used to define the hue and chroma of the recovered soil samples. 2. Conducted one double -ring infiltrometer test at a depth of 18 inches below the existing ground surface. This testing was conducted in general accordance with ,Krrierican Society for Testing. and -Materials (ASTM) precedurF' n-3385 entitled, "Infiltration Rate of Soils in Field Using Double -Ring lnfiltrometer". Based on our field classifications of the excavated soils at the hand-augered boring location, the in - place soils consist of slightly silty fine to medium sands which extended to the completed boring depth of 98 inches below the existing ground surface. No water was noted in the borehole. The site water level will fluctuate with climatic and seasonal conditions, however, and may be higher or lower at other times of the year. It is our opinion that the depth to the seasonal high water table exceeds five feet below the existing ground surface. 5&MB, Inc. (910( 799-99^_5 6409 Amsterdam Way, Bvilding 3-3 (910) 799-9958 fax i Wdrninghon, North Carolina 28405 BMS Architects, PC S&tiIE Job Number I Obi-04-305 June 22, 2004 Page Two The average infiltration rate at the test location was approximately 70 inches per hour. A summary of the field test results is presented in Table 1. SCONFE appreciates the opportunity to provide our ser'aices d^g this.phasp ofthe project. Should you have any questions after reviewing this letter, or if we can be of additional assistance, please do not hesitate to contact us at your convenience. Sincerely. S&NIE, INC. C. Richard Connell, II Senior Engineering Technician Michael W. Behen, F.E. Senior Geotechnical Engineer CRC:Iv] WBljns Attachments Copy: Criser & Troutman Consulting Engineers, Mr. Don Butler, P.E. TABLE 1 Double Ring Infiltrometer Testing Operating Room Sterile Storage Addition Cape Fear Memorial Hospital Wrightsville Avenue Wilmington, North Carolina Job No. 1063-04-305 Date of Test: June 18, 2004 Depth of Test Below Site Grade: 18 inches Depth of Water in Rings: 3'/2 inches Inner Diameter of Inner Ring: 11'/4 inches Inner Diameter of Outer Ring: 22'/z inches Depth to Water: Not encountered Average Infiltration Rate: 70 inches per hour SOIL PROFILE Depth Inches Hue Value/Chroma Soil Description 0-12 2.5 Y 3/1 Very Dark Gray Fine to Medium SAND - Trace of Silt and Organics 12-37 2.5 Y 4/1 Dark Gray Fine to Medium SAND - Trace of Silt 37-50 2.5 Y 5/6 Light Olive Brown Fine to Medium SAND - Trace of Silt 50-66 2.5 Y 6/4 Light Yellowish Brown Fine to Medium SAND - Trace of Silt 66-98 2.5 Y 712 Light Gray Fine to Medium SAND - Trace of Silt a•5 LL(_;ENI) Approximate Location of Infiltrometer Testing HOSPITAL BUILDING TRACT 1 AREA=17.142 Ac.� Note: Site plan drawing provided to S&ME by ISMS Architects personnel. SCALE: NOT TO SCALE ORSTEMLE STORAGE ADDITION FIGURE CAPE FEA1Z MEMORIAL IIOSPfTAL CHECKED BY: MVjIB WRIGHTSVILLE AVENUE DRAWN BY: ,JNS WILMINGTON, NORTH CAROLINA ENGINEERING • TESTING DATE: 6-22-04 ENVIRONWNTAL SERVICES JOB NO. 1063-04-305 DATE ►,}ems DESIGN CRISER & TROUTMAN Al,j f Vlilming;on. Consulting Engineers CHECK JOB FOR C F M lyol�l CUV a,-. North Carolina SHEET / QF JOB ivO, F r. bs° /, /s s- J' f, I)C) "44, - 3,-3 & -7 s � A-7A� �-- � G,l- /j ccr� A� �� r,Q /V--"( Y DATE DESIGN CRISER & TROUTMAN Wilmington, Consulting Engineers CHECK JOB FOR i tAs kSHEETNxth Carolina INFILTRATION BASIN -Cape Fear Memorial Hospital No. 5359 Date: 24-.1un-04 Basin Information Impervious Surface Areas Drainage Area 3,367 sf 0.08 ac On -site Buildings 3,367 sf 0.08 /% Existing Impervious Area 1,155 sf 0.03 ac On -site Streets 0 sf 0.00 Proposed Impervious Area 2,212 sf 0.05 ac On -site Parking 0 sf 0.00 On -site Sidewalks 0 sf 0.00 % Built -upon Area (C) 100,00 Other on -site 0 sf 0.00 Totals 3,367 sf 0.08 Soils Type= Urban Ur on page 19 Infiltration Rate= 35,0 inlhr (Factor of Safety = 2) Depth to Ground Water= 5 feet below surface, minimum Required Volume: (Simple Method) Design Storm= 1 in Determine Value Rv= 0.05+0.009 (1) 0.95 in/in Minimum Volume Reqd.= Rainfall x Rv Acres x 43560 12" Minimum Volume Regd.= 276 cf Trench Design Perf. Pipe 24 in_ dia. Pipe Length 42 ft Trench Dim. 3 ft. high 4 ft. wide Stone void 0A Vol./ ft. pipe Z 6.68 cf ✓ �2�e� ' ZC,2t�� Drawdown time= 0.6 hrs t Prov1,c e& votum.- = 10ffi-%StortttwatertStale Wei Pond