HomeMy WebLinkAboutSW8031044_CURRENT PERMIT_20040108STORMWATER DIVISION CODING SHEET
POST -CONSTRUCTION PERMITS
PERMIT NO.
SW
DOC TYPE
� CURRENT PERMIT
APPROVED PLANS
❑ HISTORICAL FILE
❑ COMPLIANCE EVALUATION INSPECTION
DOC DATE
vyi5li)/!k
WYYMMDD
W A rF9
Michael F Easley Governor
OF
QG
William G Ross Jr, Secretary
O�
North Carolina Department of Environment and Natural Resources
Alan W Klimek, P E Director
0
Division of Water Quality
Coleen H Sullins, Deputy Director
Division of Water Quality
January 8, 2004
Mr Ricky Parker, President
F & R Development, Inc
1861 Holden Beach Road SW
Supply, NC 28462
Subject Permit No SW8 031044
Parker Retail
High Density Stormwater Project
Brunswick County
Dear Mr Parker
The Wilmington Regional Office received a complete Stormwater Management Permit Application for
Parker Retail on January 5, 2004 Staff review of the plans and specifications has determined that the
project, as proposed, will comply with the Stormwater Regulations set forth in Title 15A NCAC 2H 1000
We are forwarding Permit No SW8 031044 dated January 8, 2004, for the construction of Parker Retail
This permit shall be effective from the date of issuance until January 8, 2014, and shall be subject to the
conditions and limitations as specified therein Please pay special attention to the Operation and
Maintenance requirements in this permit Failure to establish an adequate system for operation and
maintenance of the stormwater management system will result in future compliance problems
If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to
request an adjudicatory hearing upon written request within thirty (30) days following receipt of this
permit This request must be iti the form of a written petition, conforming to Chapter 150B of the North
Carolina General Statutes, and fled with the Office of Administrative Hearings, P O Drawer 27447,
Raleigh, NC 27611-7447 Unless such demands are made this permit shall be final and binding
If you have any questions, or need additional information concerning this matter, please contact Laurie
Munn, or me at (910) 395-3900
Sincerely,
Rick Shiver
Water Quality Regional Supervisor
RSSI Ism S IWQSISTORMWAT FRMIT1031044 jan04
cc Phil Norris, P E
Brunswick County Building Inspections
Laurie Munn
Wilmington Regional Office
Central Files
N C Division of Water Quality 127 Cardinal Drive Extension (910) 395-3900 Customer ServiceQ
Wilmington Regional Office Wilmington, NC 28405 (910) 350-2004 Fax 1 800 623-7748 nc ENR
State Stormwater Management Systems
Permit No SW8 031044
STATE OF NORTH CAROLINA
DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES
DIVISION OF WATER QUALITY
STATE STORMWATER MANAGEMENT PERMIT
HIGH DENSITY DEVELOPMENT
In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North
Carolina as amended, and other applicable Laws, Rules, and Regulations
PERMISSION IS HEREBY GRANTED TO
F c& R Development, Inc
Parker Retail
Brunswick County
FOR THE
construction, operation and maintenance of an infiltration basin in compliance with the
provisions of 15A NCAC 2H 1000 (hereafter referred to as the "stormwater rules') and the
approved stormwater management plans and specifications and other supporting data as attached
and on file with and approved by the Division of Water Quality and considered a part of this
permit
This permit shall be effective from the date of issuance until January 8, 2014, and shall be subject
to the following specified conditions and limitations
I. DESIGN STANDARDS
1 This permit is effective only with respect to the nature and volume of stormwater
described in the application and other supporting data
2 This stormwater system has been approved for the management of stormwater runoff as
described on page 3 of this permit, the Project Data Sheet The stormwater control has
been designed to handle the runoff from 27,671 square feet of impervious area This
device must be operated with a vegetated filter
The tract will be limited to the amount of built -upon area indicated on page 3 of this
permit, and per approved plans _
4 All stormwater collection and treatment systems must be located in either dedicated
common areas or recorded easements The final plats for the project will be recorded
showing all such required easements, in accordance with the approved plans
The runoff from all built -upon area within the permitted drainage area of this project must
be directed into the permitted stormwater control system A permit modification must be
submitted and approved prior to the construction of additional built -upon area from
outside of the approved drainage area
2
E
State Stormwater Management Systems
Permit No SW8 031044
DIVISION OF WATER QUALITY
PROJECT DESIGN DATA SHEET
Project Name
Parker Retail
Permit Number
SW8 031044
Location
Brunswick County
Applicant
Mr Ricky Parker
Mailing Address
F & R Development, Inc
1861 Holden Beach Road SW
Supply, NC 28462
Application Date
January 5, 2004
Receiving Stream/River Basin
UT Shallotte Creek / Lumber
Stream Index Number
LBR59 15-25-2-15-(3)
Classification of Water Body
"SA HQW"
Drainage Area, acres
121
Onsite, sq ft
52,799
Offslte, sq ft
none, per engineer
Total Impervious Surfaces, sq f
27,671
Pond Depth, feet
12
Bottom Elevation, FMSL
368
Bottom Surface Area, ft2
2,522
Permitted Storage Volume, ft3
3,775
Temporary Storage Elevation, FMSL
380
Seasonal High Water Table Elev
305
Type of Soil
Sand
Expected Infiltration Rate
25 inches per hour
Time to Draw Down
0 8 hours
3
r
State Stormwater Management Systems
Permit No SW8 031044
II SCHEDULE OF COMPLIANCE
1 The stormwater management system shall be constructed in its entirety, vegetated and
operational for its intended use prior to the construction of any built -upon surface
2 During construction, erosion shall be kept to a minimum and any eroded areas of the
system will be repaired immediately
3 The permittee shall at all times provide the operation and maintenance necessary to assure
the permitted stormwater system functions at optimum efficiency The approved
Operation and Maintenance Plan must be followed in its entirety and maintenance must
occur at the scheduled intervals including, but not limited to
a Semiannual scheduled inspections (every 6 months)
b Sediment removal
c Mowing and revegetation of slopes and the vegetated filter
d Immediate repair of eroded areas
e Maintenance of all slopes in accordance with approved plans and specifications
f Debris removal and unclogging of outlet structure, onfice device, flow spreader,
catch basins and piping
g Access to the outlet structure must be available at all times
4 Records of maintenance activities must be kept and made available upon request to
authorized personnel of DWQ The records will indicate the date, activity, name of
person performing the work and what actions were taken
5 Decorative spray fountains will not be allowed in the stormwater treatment system
6 The facilities shall be constructed as shown on the approved plans This permit shall
become voidable unless the facilities are constructed in accordance with the conditions of
this permit, the approved plans and specifications, and other supporting data
7 Upon completion of construction, prior to issuance of a Certificate of Occupancy, and
prior to operation of this permitted facility, a certification must be received from an
appropriate designer for the system installed certifying that the permitted facility has been
installed in accordance with tlus permit, the approved plans and specifications, and other
supporting documentation Any deviations from the approved plans and specifications
must be noted on the Certification A modification may be required for those deviations
If the stormwater system was used as an Erosion Control device, it must be restored to
design condition prior to operation as a stormwater treatment device, and prior to
occupancy of the facility
9 The permittee shall submit to the Director and shall have received approval for revised
plans, specifications, and calculations prior to construction, for any modification to the
approved plans, including, but not limited to, those listed below
a Any revision to any item shown on the approved plans, including the stormwater
management measures, built -upon area, details, etc
b Project name charge
c Transfer of ownership
d Redesign or addition to the approved amount of built -upon area or to the drainage
area
e Further subdivision, acquisition, or sale of all or part of the project area The
project area is defined as all property owned by the permittee, for which
Sedimentation and Erosion Control Plan approval or a CAMA Major permit was
sought
f Filling in, altering, or piping of any vegetative conveyance shown on the approved
plan
4
State Stormwater Management Systems
Permit No SW8 031044
10 The permittee shall submit final site layout and grading plans for any permitted future
areas shown on the approved plans, prior to construction If the proposed BUA exceeds
the amount permitted under this permit, a modification to the permit must be submitted
and approved prior to construction
11 A copy of the approved plans and specifications shall be maintained on file by the
Penmittee for a minimum of ten years from the date of the completion of construction
12 At least 30 days prior to the sale or Iease of any portion of the property, the permittee
shall notify DWQ and provide the name, mailing address and phone number of the
purchaser or leasee An access/maintenance easement to the stormwater facilities shall be
granted in favor of the permittee if access to the stormwater facilities will be restricted by
the sale or lease of any portion of the property
13 The permittee must maintain compliance with the proposed built -upon area and ensure
that the runoff from all the built -upon is directed into the permitted system
14 The Director may notify the permittee when the permitted site does not meet one or more
of the minimum requirements of the permit Within the time frame specified in the notice,
the permittee shall submit a written time schedule to the Director for modifying the site to
meet minimum requirements The permittee shall provide copies of revised plans and
certification in writing to the Director that the changes have been made
15 The permittee must maintain the current permitted drainage area No additional runoff
from outside of the permitted drainage area boundary may enter the permuted stormwater
facilities without first applying for and receiving a permit modification
III GENERAL CONDITIONS
1 This permit is not transferable except after notice to and approval by the Director In the
event of a change of ownership, or a name change, the permittee must submit a formal
permit transfer request to the Division of Water Quality, accompanied by a completed
name/ownership change form, documentation from the parties involved, and other
supporting materials as may be appropriate The approval of this request will be
considered on its merits and may or may not be approved The permittee is responsible
for compliance with all permit conditions until such time as the Division approves the
transfer request
2 Failure to abide by the conditions and limitations contained in this permit may subject the
Permittee to enforcement action by the Division of Water Quality, in accordance with
North Carolina General Statute 143-215 6A to 143-215 6C
3 The issuance of this permit does not preclude the Permittee from complying with any and
all statutes, rules, regulations, or ordinances which may be imposed by other government
agencies (local, state, and federal) which havejunsdiction
4 In the event that the facilities fail to perform satisfactorily, including the creation of
nuisance conditions, the Pennittee shall take immediate corrective action, including those
as may be required by this Division, such as the construction of additional or replacement
stormwater management systems
5 The permittee grants DENR Staff permission to enter the property during normal business
hours for the purpose of inspecting all components of the permitted stormwater
management facility
6 The permit maybe modified, revoked and reissued or terminated for cause The filing of
a request for a permit modification, revocation and reissuance or termination does not
stay any pen -nit condition
5
State Stormwater Management Systems
Permit No SW8 031044
7 Unless specified elsewhere, permanent seeding requirements for the stormwater control
must follow the guidelines established in the North Carolina Erosion and Sediment
Control Planning and Design Manual
8 Approved plans and specifications for this project are incorporated by reference and are
enforceable parts of the permit
9 The penmttee shall notify the Division any name, ownership or mailing address changes
within 30 days
Permit issued this the 8th day of January 2004
NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION
Alan W Klimek, P E , Director
`�•_-�`t Division of Water Quality
By Authority of the Environmental Management Commission
L
State Stormwater Management Systems
Permit No SW8 031044
Parker Retail
Stormwater Permit No SW8 031044
Brunswick County
Designer's Certification
as a duly registered
in the State of North Carolina, having been authorized to observe (penodically/weekly/full time)
the construction of the project,
(Project)
for
ect Owner) hereby state that, to the best of
my abilities, due care and diligence was used in the observation of the project construction such
that the construction was observed to be built within substantial compliance and intent of the
approved plans and specifications
The checklist of items on page 2 of this form is included in the Certification
Noted deviations from approvedplans and specification
Signature
Registration Number
Date
SEAL
7
State Stormwater Management Systems
Permit No SW8 031044
Certification Requirements
1 The drainage area to the system contains approximately the permitted acreage
2 The drainage area to the system contains no more than the permitted amount of
built -upon area
3 All the built -upon area associated with the project is graded such that the runoff
drains to the system
4 The outlet/bypass structure elevations are per the approved plan
5 The outlet structure is located per the approved plans
6 Trash rack is provided on the outlet/bypass structure
7 All slopes are grassed with permanent vegetation
8 Vegetated slopes are no steeper than 3 1
9 The inlets are located per the approved plans and do not cause short-circuiting of
the system
10 The permitted amounts of surface area and/or volume have been provided
11 Required drawdown devices are correctly sized per the approved plans
12 All required design depths are provided
13 All required parts of the system are provided, such as a vegetated shelf, and a
forebay
14 The overall dimensions of the system, as shown on the approved plans, are
provided
cc NCDENR-DWQ Regional Office
Brunswick County Building Inspections
E
A&K #03191
n�>~rrr;_ric>~_nrir v
D to Rpceived
Fee Pad
Pe it Number
3
'=
d
State of North Carolina
Department of Environment and Natural Resources
Division of Water Quality
STORMWATER MANAGEMENT PERMIT APPLICATION FORM
This form may be photocopied for use as an original
I GENERAL INFORMATION
i Applicants name (specify the name of the corporation, individual, etc who owns the project)
F & R Development, Inc
2 Print Owner/Signing Official's name and title (person legally responsible for facility and compliance)
Ricky Parker, President
3 Mailing Address for person listed in item 2 above
1861 Holden Beach Road SW
City Supply State NC Zip 28462
Telephone Number 910 842-4003
4 Project Name (subdivision, facility, or establishment name — should be consistent with project name on
plans, specifications, letters, operation and maintenance agreements, etc )
Parker Retail
5 Location of Project (street address)
1861 Holden Beach Road SW
City Holden Beach County
6 Directions to project (from nearest major intersection)
Brunswick
From intersection of US 17 Business and NC 130, take NC 130 toward Holden Beach Site is
at intersection of NC 130 & Elk Road
7 Latitude 330 56' 48"
Longitude 780 18' 34"
of project
S Contact person who can answer questions about the project
Name Ricky Parker , Telephone Number (910) 842-4003
II PERMIT INFORMATION
1 Specify whether project is (check one)
X New
Form SWU-101 Version 3 99 Page 1 of 4
Renewal Modification
2
3
4
If this application is being submitted as the result of a renewal or modification to an existing permit, list the
Existing permit number NIA And its issue date (if known) NIA
Specify the type of project (check one)
Low Density X High Density Redevelop General Permit Other
Additional Project Requirements (check applicable blanks)
CAMA Major X Sedimentation/Erosion Control 404/401 Permit NPDES Stormwater
Information on required state permits can be obtained by contacting the Customer Service Center at
1-877-623-6748
III PROJECT INFORMATION
I In the space provided below, summarize how stormwater will be treated Also attach a detailed narrative
(one to two pages) describing stormwater management for the project
Infiltration Basin
2 Stormwater runoff from this project drains to the
3 Total Protect Area 1 21 AC
C2et-L'E Lltim�'be'r River Basin
4 Project Built Upon Area 524
5 How many drainage areas does the project have? 1
6 Complete the following information for each drainage area If there are more than two drainage areas in the
project, attach an additional sheet with the information for each area provided in the same format as below
Basin Information
Drains a Area 1
Drainage Area 2
Receiving Stream Name
UT Shallotte Creek
Receiving Stream Class
SA
Drainage Area
52,799 SF / 121 AC
Existing Impervious * Area
NIA
Proposed Im ervious* Area
27 671 SF 10 635 AC
% Impervious* Area(total)_52
4%
Impervious* Surface Area
Drainage Area 1
Drainage Area 2
On -site Buildm s
12 416 SF 10 28 AC
On -site Streets
On -site Parking
13,722 SF 10 32 AC
On -site Sidewalks
1,533 SF 10 035 AC
Other on -site
0
Off -site
0
Total 27,671 SF 10 635 AC
Total
Impervious area is dejined as the built upon area including, but not limited to, buildings, roads, parking areas
sidewalks, gravel areas, etc
Form SWU-101 Version 3 99 Page 2 of 4
7 How was the off -site impervious area listed above derived?
NIA
IV DEED RESTRICTIONS AND PROTECTIVE COVENANTS
The following italicized deed restrictions and protective covenants are required to be recorded for all
subdivisions, outparcels and future development prior to the sale of any lot If lot sizes vary significantly, a
table listing each lot number, size and the allowable built -upon area for each lot must be provided as an
attachment
The following covenants are intended to ensure ongoing compliance with state stormwater management permit
number as issued by the Division of Water Quality These covenants may
not be changed or deleted without the consent of the State
2 No more than 27,671 squarefeet ofany lot shall be covered by structures or impervious materials
Impervious materials include asphalt, gravel, concrete, brick, stone, slate or similar material but do not include
wood decking or the water surface of swimming pools
Swales shall not be filled in, piped, or altered except as neces vary to provide driveway crossings
4 Built -upon area in excess of the permitted amount requires a state stormwater management permit modification
prior to construction
All permitted runofffrom outparcels or future development shall be directed into the permitted stormwater control
system These connections to the stormwater control system shall be performed in a manner that maintains the
integrity and performance of the system as permitted
By your signature below, you certify that the recorded deed restrictions and protective covenants for this project
shall include all the applicable items required above, that the covenants will be binding on all parties and persons
claiming under them, that they will run with the land, that the required covenants cannot be changed or deleted
without concurrence from the State, and that they will be recorded prior to the sale of any lot
V SUPPLEMENT FORMS
The applicable state stormwater management permit supplement form(s) listed below must be submitted for
each BMP specified for this project Contact the Stormwater and General Permits Unit at (919) 733-5083 for
the status and availability of these forms
Form SWU-102
Form SWU-103
Form SWU-104
Form SWU-105
Form SWU-106
Form SWU-107
Form SWU-108
Form SWU-109
Wet Detention Basin Supplement
Infiltration Basin Supplement
Low Density Supplement
Curb Outlet System Supplement
Off -Site System Supplement
Underground Infiltration Trench Supplement
Neuse River Basin Supplement
Innovative Best Management Practice Supplement
Form SWU-101 Version 3 99 Page 3 of 4
VI SUBMITTAL. REQUIREMENTS
Only complete application packages will be accepted and reviewed by the Division of Water Quality (DWQ).
A complete package includes all of the items listed below. The complete application package should be
submitted to the appropriate DWQ Regional Office.
Please indicate that you have provided the following required information by initialing in the space provided
next to each item
• Original and one copy of the Stormwater Management Permit Application Form
• One copy of the applicable supplement form(s) for each BMP
• Permit application processing fee of $420 (payable to NCDENR)
• Detailed narrative description of stormwater treatment / management
• Two copies of plans and specifications, including
- Development / Project name
- Engineer and firm
- Legend
- North arrow
- Scale
- Revision number & date
- Mean high water line
- Dimensioned property / project boundary
- Location map with named streets or NCSR numbers
- Original contours, proposed contours, spot elevations, finished floor elevations
- Wetlands delineated, or a note on plans that none exist
- Existing drainage (including off -site), drainage easements, pipe sizes, runoff calculations
- Drainage areas delineated
- Vegetated buffers (where required)
VII AGENT AUTHORIZATION
If you wish to designate authority to another individual or firm so that they may provide information on your
behalf, please complete this section
J Phillip Norris, P E
Designated agent (individual or firm) Andrew & Kuske Consulting Engineers, Inc
Mailing Address 902 Market Street
City Wilmington State NC Zip 28401
Phone (910) 343-9653 Fax (910) 343-9604
VIII. APPLICANT'S CERTIFICATION
1, (print or type name ofperson listed in General Information, item 2) Ricky Parker President ,
Certify that the information included on this permit application form is, to the best of my knowledge, correct and
that the project will be constructed in conformance with the approved plans, that the required deed restrictions and
protective covenants will he recorded, and that the proposed project complies with the requirements of 15A NCAC
2H 1000 /)
Signature
Form SWU-101 Version 3 99 Page 4 of 4
Date / �p/2�i
0
Andrew & Kuske
CONSULTING ENGINEERS INC
902 Market Street Wilmington NC 2W1 4733
910/343 9553 9101343 9604 Fax
www ondrewandkuske com
TO Linda Lewis, Environmental Engineer
NC DENR/Division of Environmental Management
Water Quality Section
127 Cardinal Drive Extension
Wilmington, NC 28405-3845
RE Parker Retail
Holden Beach, NC
A&K Project No 03191
Engineer's Certification
John R Andrew P F J Phillip Norris P E
John S Tunstall P E Neal W Andrew P E
John A Kuske III P E J A Kuske P E of Counsel
James T Pyrtle P E C Lawrence Sneedon Jr P E
State Stormwater Management Systems
Permit No SW8 031044
MAY 0 5
�k
1, J Phillip Norris, P E , as a duly registered Professional Engineer in the State of
North Carolina, having been authorized to observe (periodically, weekty, Ul 4me) the construction of the project,
Parker Retai I
(Project)
for F & R Development, Inc (Project Owner) hereby state that, to the best of my abilities, due
care and diligence were used in the observation of the project construction such that the construction was observed
to be built within substantial compliance and intent of the approved plans and specifications
Required items to be checked for this certification to be considered complete are on page 2 of this form
Noted deviations from approved plans and specifications
J PN/asn
vate May 3, 1UU5
cc Tony Roberts, New Hanover County Building Inspector
Ricky Parker / F & R Development, Inc
SEAL
•`�ZN CAR
�: •��QQp`ESST� /y9 �
SEAL i
11966
;
0.
ti�,,lHILL1P �.►'
,
Certification Requirements
drainage area to the system contains approximately the permitted acreage
drainage area to the system contains no more than the permitted amount of built -upon area
the built -upon area associated with the project is graded such that the runoff drains to the
em
g;
/2Zhe outlet/bypass structure elevations are per the approved plan
outlet structure is located per the approved plans
�5 Trash rack is provided on the outletibypass structure
All slopes are grassed with permanent vegetation
Vegetated slopes are no steeper than 3 1
e inlets are located per the approved plans and do not cause short-circuiting of the system
he permitted amounts of surface area and/or volume have been provided
I I Required drawdown devices are correctly sized per the approved plans
12 All required design depths are provided
��kl3 11 required parts of the system are provided, such as vegetated shelf, and a forebay
a14 The overall dimensions of the system, as shown on the approved plans, are provided
cc Tony Roberts, New Hanover County Building Inspector
Ricky Parker / F & R Development, Inc