HomeMy WebLinkAboutSW7960912_HISTORICAL FILE_202005121\ STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW 7C%VB8a DOC TYPE ❑ CURRENT PERMIT ❑ APPROVED PLANS HISTORICAL FILE DOC DATE OS - YYYYMMDD tA/ti'(k6 ROY COOPER Governor MICHAEL S.'REGAN Secretary SRIAN WRENN Acting mlrector NORTH CAROLINA Environmental Qua[tty May 12, 2020 Bergman Filarecki Development, LLC Attention: Mr. Arthur Bergman 905 Halstead Blvd., Unit 30 Elizabeth City, NC 27909 Subject: Stormwater Permit Renewal Stormwater Management Permit SW7960912 Winchester Station Pasquotank County Dear Mr. Bergman: A Division of Energy, Mineral, and Land Resources file review has determined that Stormwater Permit SW7960912 for a stormwater treatment system consisting of three wet detention ponds serving Winchester Station located at 905 Halstead Blvd. in Elizabeth City, NC expires on November 15, 2020. This is a reminder that permit renewal applications are due 180 days prior to expiration, We do not have a record of receiving a. renewal application. Please submit a completed permit renewal application along with a $505.00 fee for permit renewal. Permit application forms for renewal can be found on our website at: 1aps: ,[/deq.nc,gov/abo /divisions/energ -mineral-la_Dd-resourcef=ergy-n neral-land_ rules/stormwater-nroeram/nost-construction. North Carolina General Statutes and the Coastal Stormwater rules require that this property be covered under a stormwater permit. Failure to maintain a permit subjects the owner to assessment of civil penalties If you have questions, please feel free to contact me at (252) 948-3923. 1 will be glad to discuss this by phone or meet with you. If you would like, l can e-mail you a copy of the application form. You can request a copy by e-mailing me at roAer.thope@ncdenr.gov. Sincerely, Roger K. Thorpe Environmental Engineer ��� � North Carolina Department of Environmental Quality 1 Division of Energy. Mineral and Land Resources Washington Regional Office 1 943 Washington Square Mail I Washington. North Carolina 27889 +a +=-"7' .0� 252 946.6481 vat tt01 ?)M f o�0F WA7§ Michael F. Easley, Governor William G. Ross Jr., Secretary co r North Carolina Department of Environment and Natural Resources Q -C Alan W. Klimek, P.E. Director Division of Water Quality July 17, 2006 Berg man-Filarecki Development, LLC Attn: Mr. Arthur Bergman 786 Pitts Chapel Road Elizabeth City, NC Subject: Stormwater Permit SW7960912 Winchester Station Pasquotank County Dear Mr.Bergman: This office received your request to renew the existing stormwater permit for Winchester Station located at Elizabeth City, NC. Your request indicated that you do not have a copy of your Operation & Maintenance Agreement for the (3) wet pond systems. In order to complete the renewal request, and before the permit can be renewed, the following items must be addressed: 1) Submit the enclosed Wet Detention Basin Supplement Sheet. 2) Provide any information regarding changes to the treatment system. The above requested information must be received in this office prior to August 17, 2006, or your application will be returned as incomplete. The return of this project will necessitate resubmittal of all required items including the application fee. If you need additional time to submit the required information, please mail or fax your request for time extension to this office at the Letterhead address. If you have questions, please feel free to contact me at (252) 948-3919. Sincerel William J. Mo Environmental Engineer Washington Regional Office cc: Hyman & Robey Elizabeth City Planning/inspections Washington Regional Office pnc NvCaro ,Aamrat North Carolina Division of Water Quality Washington Regional Office Phone (252) 946-6481 FAX (252) 946-9215 Customer Service Internet: h2o.enr.state.mus 943 Washington Square Mall, Washington, NC 27889 1.877.623-6748 An Equal OpportunitylAffirmadve Action Employer— 50% Recycledll0% Post Consumer Paper Permit No. (to be provided by DWQ) State of North Carolina Department of Environment and Natural Resources Division of Water Quality STORMWATER MANAGEMENT PERMIT APPLICATION FORM `]VET DETENTION BASIN SUPPLEMENT This form may be photocopied for use as an original DWQ Stonnwater Management Plan Review: A complete stormwater management plan submittal includes an application form, a wet detention basin supplement for each basin, design calculations, and plans and specifications showing all basin and outlet structure details. 1. PROJECT INFORMATION Project Name: Contact Person: Phone Number: ( } For projects with multiple basins, specify which basin this worksheet applies to: elevations Basin Bottom Elevation Permanent Pool Elevation Temporary Pool Elevation areas Permanent Pool Surface Area Drainage Area Impervious Area' volumes Pennanent Pool Volume Temporary Pool Volume Forebay Volume Other parameters SA/DAI Diameter of Orifice Design Rainfall Design TSS Removal' - ft. (floor of the basin) ft. (elevation of the orifice) k (elevation of the discharge structure overflow) sq. ft. (water surface area at the orifice elevation) ac, (on -site and off=site drainage to the basin) ac. (on -site and off -site drainage to the basin) cu. ft, (combined volitme of main basin and forebay) cu. ft. (volume detained above the permanent pool) cu. ft. (approximately 20% of'total v0111177e) (surface area to drainage area ratio from 'DWQ table) in. (2 to 5 day temporary pool draw -down required) in. % (minimum 85% required) Form SWU-102 Rev 3.99 Page t of 4 Footnotes: When using the Division SA/DA tables, the correct SA/DA ratio for permanent pool sizing should be computed based upon the actual impervious % and permanent pool depth. Linear interpolation should be employed to determine the correct value for non- standard table entries. In the 20 coastal counties, the requirement for a vegetative filter may be waived if the wet detention basin is designed to provide 90% TSS removal. The NCDENR BMP manual provides design tables for both 85% TSS removal and 90% TSS removal. II. REQUIRED ITEMS CHECKLIST The following checklist outlines design requirements per the Stormwater Best Management Practices Manual (N.C. Department of Environment, Health and Natural Resources, February 1999) and Administrative Code Section: 15 A NCAC 2H .1008.- Initial in the space provided to indicate the following design requirements have been met and supporting documentation is attached. If the applicant has designated an agent in the Stormwater Management Permit Application Form, the agent may initial below. If a requirement has not been met, attach justification. Applicants Initials a. The permanent pool depth is between 3 and 6 feet (required minimum of 3 feet). b. The forebay volume is approximately equal to 20% of the basin volume. c. The temporary pool controls runoff from the design storm event. d. The temporary pool draws down in 2 to 5 days. e. If required, a 30-foot vegetative filter is provided at the outlet (include non -erosive flow calculations) f. The basin length to width ratio is greater than 3:1. g. The basin side slopes above the permanent pool are no steeper than 3:1. h. A submerged and vegetated perimeter shelf with a slope of 6:1 or less (show detail). is Vegetative cover above the permanent pool elevation is specified. j. A trash rack or similar device is provided for both the overflow and orifice. k. A recorded drainage easement is provided for each basin including access to nearest right- of-way. I. If the basin is used for sediment and erosion control during construction, clean out of the basin is specified prior to use as a wet detention basin. in. A mechanism is specified which will drain the basin for maintenance or an emergency. III. WET DETENTION BASIN OPERATION AND MAINTENANCE AGREEMENT The wet detention basin system is defined as the wet detention basin, pretreatment including forebays and the vegetated filter if one is provided. This system (check one) 0 does 0 does not incorporate a vegetated filter at the outlet. This system (check one) 0 does 0 does not incorporate pretreatment other than a forebayy. Form SWU-102 Rev 3.99 Page 2 of 4 C.� Maintenance activities shall be performed as follows: 1. After every significant runoff producing rainfall event and at least monthly: a. Inspect the wet detention basin system for sediment accumulation, erosion, trash accumulation, vegetated cover, and general condition. b. Check and clear the orifice of any obstructions such that drawdown of the temporary pool occurs within 2 to 5 days as designed. 2. Repair eroded areas immediately, re -seed as necessary to maintain good vegetative cover, mow vegetative cover to maintain a maximum height of six inches, and remove trash as needed. 3. Inspect and repair the collection system (i.e. catch basins, piping, swales, riprap, etc.) quarterly to maintain proper functioning. 4. Remove accumulated sediment from the wet detention basin system semi-annually or when depth is reduced to 75% of the original design depth (see diagram below). Removed sediment shall be disposed of in an appropriate manner and shall be handled in a manner that will not adversely impact water quality (i.e. stockpiling near a wet detention basin or stream, etc.). The measuring device used to determine the sediment elevation shall be such that it will give an accurate depth reading and not readily penetrate into accumulated sediments. ' When the permanent pool depth reads feet in the main pond, the sediment shall be removed. When the permanent pool depth reads feet in the forebay, the sediment shall be removed. BASIN DIAGRAM (fill in the blanks) Permanent Pool Elevation Sediment Removal El. --------------VSediment Removal Elevation 75% Bottom E!e -ation --------------------------------------------- ------ FOREBAY Bottom Elevation MAIN POND 25% 5. Remove cattails and other indigenous wetland plants when they cover 50% of the basin surface. These plants shall be encouraged to grow along the vegetated shelf and forebay berm. 6. If the basin must be drained- for an emergency or to perform maintenance, the flushing of sediment through the emergency drain shall be minimized to the maximum extent practical. Forni SWU-102 Rev 3.99 Page 3 of 4 7. All components of the wet detention basin system shall be maintained in good working order. I acknowledge and agree by my signature below that i am responsible for the performance of the seven maintenance procedures listed above. I agree to notify DWQ of any problems with the system or prior to 'any changes to the system or responsible party. Print name: Title: Address: Phone: Signature:_ Date: Note: The legally responsible party should not be a homeowners association unless more than 50% of the lots have been sold and a resident of the subdivision has been named the president. a Notary Public for the State of , County of do hereby certify that personally appeared before me this day of and acknowledge the due execution of the forgoing wet detention basin maintenance-requireinents. Witness my hand and official seal, SEAL My cominission expires_ Form SWU-102 Rev 3.99 Page 4 of 4 Nficbael F. Easley, Governor William G. Ross Jr., SeReta y North Carolina Depattmrat of Envwonmed and Natural Resources Alan W. Klimek, P.E. Director Division of Water Quality May 15, 2005 Mr. Arthur Bergman 2135 Rivershore Rd. Elizabeth City, NC 27909 Subject: PERMIT RENEWAL Stormwater Permit No. SW 7%W12 Winchester Station Pasquotank Dear Mr. Gary Filareski, The Division of Water Quality issued a Coastal Stormwater Management Permit, Number SW 7960912 to West Seneca Inv & BEL prop. LLC. for Winchester Station on 12/23/1996. This permit expires on 12/2312006. Section .1003(h) of 15 A NCAC 2H .1000 (the stormwater rules) requires that applications for permit renewals shall be submitted 180 days prior to the expiration of a permit and must be accompanied by a processing fee, which is currently set at $420.00. However, if your permit has already expired, you need to send in your.application for renewal as soon as possible. If this is still an active project please complete and submit the enclosed renewal application in a timely manner. If this project has not been constructed and a permit is no longer needed, please submit a request to have the permit rescinded. If you have. sold the project, or are no longer the permittee, please provide the name, mailing address and phone number of the person or entity that is now responsible for this permit. Enclosed is a form for change of ownership, which should be completed and submitted if the property has changed hands. Your permit requires that upon completion of construction and prior to operation of the permitted treatment units a certification of completion be submitted to the Division from an appropriate designer for the system installed. This is to certify that the permitted facility has been installed in accordance with the permit, the approved plans, specifications and supporting documentation. Please include a copy of the certification with your permit renewal request and processing fee. Enclosed is a copy of a sample certification. You should be aware that failure to provide the Designer's Certification and the operation of a stormwater treatment facility without a valid permit, are violations of NC General Statute 143-215.1 and may result in appropriate enforcement action including the assessment of civil penalties of up to $10,000 per day. If you have any questions, please feel free to contact me or a member of the coastal stommwater staff with DWQ at 252-946-6481. Zg—e, S' ly, R i a �ersoc� Surface Water Protection Section Washington Regional Office Enclosures cc: Hyman & Robey Washington Regional Office North Carolina Division of Water Quality Internet wwwncwatett9u3litv.or¢ �TOne 943 Washington Square Mall Pbone (252) 94&6481 l�l C`aro na Washingtm NC 27889 Fax (252) 946-9215 ���/yt� I� u i� Michael F_ Easley, Governor William G. Ross Jr, Searelary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P-E_ Director Division of Water Quality May 3, 2005 Im 204 Binnacle Court ' Elizabeth City, NC 27909 a �� Subject PERMIT RENEWAL AIL. 2796 e oo. SW 7960912 osqchester Station ?uo n ' Dear Mr. Gary Flareski, The Division of Water Quality issued a Coastal Stormwater Management Permit, Number SW 7960912 to West Seneca Inv 8 BFL prop. LLC. for Winchester Station on 12/23119%. This permit expires on 12/23/2006. Section .1003(h) of 15 A NCAC 2H .1000 (the stormwater rules) requires that applications for permit renewals shall be submitted 180 days prior to the expiration of a permit and must be accompanied by a processing fee, which is currently set at $420.00. However, if your permit has already expired, you need to send in your application for renewal as soon as possible. If this is still an active project please complete and submit the enclosed renewal application in a timely manner. If this project has not been constructed and a permit is no longer needed, please submit a request to have the permit rescinded. If you have sold the project, or are no longer the permittee, please provide the name, mailing address and phone number of the person or entity that is now responsible for this permit. Enclosed is a form for change of ownership, which should be completed and submitted if the property has changed hands_ Your permit requires that upon completion of construction and prior to operation of the permitted treatment units a certification of completion be submitted to the Division from an appropriate designer for the system installed. This is to certify that the permitted facility has been installed in accordance with the permit, the approved plans, specifications and supporting documentation. Please include a Copy of the certification with your permit renewal request and processing fee. Enclosed is a copy of a sample certification. You should be aware that failure to provide the Designer's Certification and the operation of a stonmwater treatment facility without a valid permit, are violations of NC General Statute 143-215.1 and may result in appropriate enforcement action including the assessment of civil penalties of up to $10,000 per day. If you have any questions, please feel free to contact me or a member of the coastal stormwater staff with DWQ at 252-946-6481. ZZncer9 e�e, I r Surface Water Protection Section Washington Regional Office Cc: Hyman & Robey Washington Regional Office North Carolina Division of WsW Quality hRaroet: Www+r.ncwalemualitv.org �TOne 7 943 Washington Square Mall Phone (252) 94&6U l 1 V of ihCarolina Washington, NC 27M Fax (252) 946-9215 6jrf t/rjflly litt p://-�+,�vw.secrelary. state.nc.us/corporations/Corp. asps'?Pi lcniId= North Carolina Elaine F Marshall 'SPAR TMENT OF-1-1-1E Secretary ECRETARY 0 F TAT E Corporations *Corporations Home °Important Notice *Corporate Forms/Fees °Corporations FAQ °Tobacco Manufacturers *Dissolution Reports 'Non -Profit Reports °Verify Certification *Online Annual Reports °KBBE B2B Annual Reports Links °Secretary Of State Home 'Register for E-Procurement 'Dept. of Revenue Legislation 101999 Senate Bills 02001 Bill Summaries *Annual Reports 1997 °Corporations 1997 °Other Legislation Search *By Corporate Name °Far New Corporation °By Registered Agent Online Orders *Start An Order *New Payment Procedures Contact Us "Corporations Division *Secretary of State's web site Print *Printable Page FCC R<:x ??. 3?2 Ralei ph, Nti. 2%�626.0E�: 2 `919teC1722--XN? Date: 5/15/2006 Click here to: View Document Filings I nA Print apre-populated Annual Report Form I Annual Report Count I File an Annual Report 1 Corporation Names Name Name Type NC WEST SENECA Legal INVESTMENTS, L.L.C. Limited Liability Company Information SOSID: 0348339 Status: Dissolved Date Formed: 7/14/1994 Citizenship: Domestic State of Inc.: NC Duration: DEC 2033 Registered Agent Agent Name: Registered Office Address: Registered Mailing Address: Principal Office Address: Principal Mailing Address: Filarecki, Gary D 204 Binnacle Ct Elizabeth City NC 27909 204 Binnacle Ct Elizabeth City NC 27909 No Address 204 Binnack Dr Elizabeth City NC 27909 For questions or comments about the North Carolina Secretary of State's web site, please send e-mail to Webmaster. 1 of 1 5/15/2006 1 1:41 AM ' - ecal PROJECT: Proposed Currituck Community Center Complex _ PROJECT NO.: EC05-342G Env mental CLIENT: RR]viNi PROJECT LOCATION: Currituck County, North Carolina [ions, Inc. LOCATION: See Attached Boring Location Plan ELEVATION: INA" BORING I I] LOG OF BORING DRILLER: J.Brown LOGGED BY: G.Stalls, E:LT.^ DRILLING METHOD: Mud Rotary (wash) DATE: 11-18-05 No. B-1 3 DEPTH TO - WATER> INITIAL: $ 3.5-Feet AFTER 24 HOURS: a CAVING> f- e a) o TEST RESULTS a 0Description ro E Z a o Plastic Limit Liquid Limit v Water Content - • Penetration - 0 10 20 30 40 50 60 70 12-inches TOPSOIL J J J J J J 1 a1 1 2 ....._.....:............:......:.:...:..... Gray, moist, Silty Sandy CLAY (CL), soft 2 CD!. oTan, moist, poorly graded fine to medium SAND (SP) to poorly :.... r �' L �: ! 2 3 ; ..' . • ' ' • ..• . =.. • . • . • 0 graded fine to medium SAND (SP-SM) with silt, loose to medium 1:°: < < a 1.0 ; .....;� ...........:. . . . . .:. . . . . .. , . , ; • , , , . "n dense l.f.! ! 5 Wet from 3.5-feet :! :!; F { 3 6 :.....:. 6 d J:I:rL1 5 H l:I:ti 4 s C l' 5 m a 10 5 5 ....:.....:...................:........... m` c .............. c •a J:I:L•I: :.....: o' Gray from 13-feet ,� ;!, f r 1 .....:......:............:.....:.... . 10 :......:.....:... ....... . ... 15 •1 kE I o $ ilFr•'1 20 14 ...,� Boring terminated at 20 ft. .....:......:............:..... ; ............... a a o q r 25 : r c:........................:.....:.....:..... :.....:.....:......:......:.....:.....:..... 3Q ...... - 35 ....._.......... Figure PAGE 1 of 1 Pasquotank County Tax Query Results tillp:H207.4.214.1 18/Dcparinicnts/gis/displaylax.cfni c%@LANGUAGE="JAVASCRIPT" CODEPAGE—" 1252"%> Pasquotank COUnty o sir r,.1ti�o Tax Parcel Database PIN # Owner Property Location Map Block Flood Lot Map 8911 845956 B RGMAN, ARTHUR A 001122 SUNNY ACRES DR P61-67 8900 8922 551981 BERGMAN, ARTHUR A &PATTI 00786 PITTS C RD �--- --- 124-4❑ ; 8922 $923 [G$40077 & PATTI BERGMAN, ARTHUR A 02135 RIVERSHORE RD P123A-26 8923 1 of 1 5/15/2006 11:56 AM ' ='•; PROJECT: ,Proposed Currituck Community Center Complex _ PROJECT NO.: EC05-342G eoE ral .Env mental CLIENT: RRMM PROJECT LOCATION: Currituck Coun North Carolina tions, Inc. LOCATION: See Attached Boring Location Plan . ELEVATION: INA LOG OF BORING DRILLER. J.Brown LOGGED BY: G-Stalls, E.I.T. DRILLING METHOD: Mud Rotary (wash) DATE: 11-18-05 No. BMP-1 DEPTH TO - WATER> INITIAL: -:W- 4-Feet AFTER 24 HOURS: -Tr CAVING> � o o TEST RESULTS �^ a v Description a a d E N o Plastic Limit i i Liquid Limit O -"�- 0 o m U Water Content - a 2 o Penetration - 10 20 30 40 50 60 70 :.....:.....:......:.....:........... :..... 0 24-inches TOPSOIL J J J L � J J J 1 2 � • A 2 J J J 2 2 1.6 ...... ' = . .. Reddish Tan, moist, poorly graded fine to medium SAND (SP) to ' ;'a: i, n poorly graded fine to medium SAND (SP-SM) with silt, very loose a .I. r' 2 2 3 - ..................,..... 1` ' to medium dense a: i a ......:............:.....:..... ; .... . s Wet from 4-feet . ; I; t. � � s L:.....:......:......:.....:.....:.... . - :ixr1 iTx 3 6 is T { :I. .I. ... i ... .. .. .. ... . . 4 6 i.:.... .. ' i 3 B 1.4 1771 .. �.:. 30 7:I:rt1 i... ... ' ... � .i : I;• r r .. . Gray from 13-feet i• r1. 1 6 7 9 .. 15 i :I : C r t l 12 .. ............ Boring terminated at 15 fir. 20 25 30 35 ................. Figure PAGE 1 of 1 WASHING ON�OFFICE Winchester Station NOV 0 1 1996 Detention Pond Maintenance Agreement D. E.' m. 1. Operation and maintenance of the detention pond shall be the responsibility of the owner. 2. Operation of the system is automatic upon the occurrence of a rainfall event, however, there are several maintenance items that must be attended to. First of all, there must be a lawn maintenance program where the grass around the pond will be kept mowed during the growing season of the year. It is recommended for aesthetic reasons that the Grass be mowed on at least a bi-weekly basis unless actual -rowing conditions indicate otherwise, in which case the mowing frequency should be modified to suit site conditions. 3. The outlet structure must be inspected periodically for obstructions and trash build-up. This inspection should be done approximately once every three months to include inspection of the orifice in the drawdown device to check for algae or other trash plugging the orifice, inspection of the rip -rap filter around the riser section for trash, cut weeds or grasses which may tend to plug the Filter, inspection of the trash rack for the same type of obstructions as with the rip -rap filter and an inspection of the barrel section for any obstructions such as limbs or anything else that may have passed the trash rack and pose a plugging problem. Any obstructions found shall be removed and hauled away from the pond. 4. The forebay area must be checked for sediment deposits. especially during the first year of operation. The frequency of the forebay inspections should be monthly until ail disturbed areas have been stabiiized or for a minimum of b months, whichever is longer. Thereafter, inspect forebay area every three months. To perform this inspection elevations should be taken along the perimeter of the rip -rap flow distribution/velociry dissipation pad. The bottom should approximately T to 2-1/2' below the permanent pool elevation. If this is not the case the rip -rap pad will need to be removed, the sediments excavated to the levels indicated in the details and the rip -rap pads replaced. 5. It should be noted that in addition to the inspection frequencies recommended above, the pond and its appurtenances should be inspected after any major storm event that may transport large amounts of debris to the pond. By our signature below, we, as owner/operator/mana;er/administrator of the proposed facility do hereby agree to perform the above mentioned items and maintain the proposed facility in proper operating condition. /4t_`iJ4 V9 Printed Name Printed Name Signature Signature Printed Name Signature Printed Narne Signature State of North Carolina Department of Environment, WI, Health and Natural Resources Washington Regionat Office 6.0 James B. Hunt, Jr., Governor Jonathan B. Howes, Secretary +� West Seneca Inv. & Attn: Mr. Arthur 204 Binnacle Court Elizabeth City, NC Dear Mr. Bergman: DIVISION OF WATER QUALITY December 23, 199E BFL Prop., LLC Bergman 27909 Subject: Permit No. SW7960912 Winchester Station High Density Stormwater Project Pasquotank County The Washington Regional Office received the completed Stormwater Application for the subject project on November 1, 1996. Staff review of the plans and specifications has determined that the project, as proposed, will comply with the Stormwater Regulations set forth in Title 15A NCAC 2H.1000. We are forwarding Permit No. SW7960912 dated December 23, 1996 to Mr. Arthur Bergman. This permit shall be effective from the date of issuance until December 23, 2006 and shall be subject to the conditions and limitations as specified therein. Please pay special attention to the Operation and Maintenance requirements in this permit. Failure to establish an adequate system for operation and maintenance of the stormwater management system will result in future compliance' problems. If any parts, requirements, permit are unacceptable, you h adjudicatory hearing upon written' following receipt of this permit. of a written petition, conformin Carolina General Statutes, and Administrative Hearings, P.O. Draw Unless such demands are made t binding. g or limitations contained in this ave the right to request an request within thirty (30) days This request must be in the form to Chapter 150B of the North filed with the Office of er 27447, Raleigh, NC 27611-7447. his permit shall be final and 1424 Carolina Avenue, Washington, NC 27889 An Equal Opportunity Affirmative Action Employer Telephone (919) 946-6481 FAX (919) 975-3716 50% recycled / 10% post -consumer paper Mr. Arthur Bergman December 23, 1996 Page Two If you have any questions, or need additional information concerning this matter, please contact Bill Moore at (919) 946- 6481, extension 264. Sincerely, 4 Roger K. Thorpe Water Quality Supervisor Washington Regional Office cc: Robey Associates Pa�quotank County Inspections Washington Regional Office Central Files State Stormwater Management Systems Permit No. SW7960912 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT, HEALTH AND NATURAL RESOURCES DIVISION OF WATER QUALITY STATE STORMWATER MANAGEMENT PERMIT HIGH DENSITY DEVELOPMENT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO West Seneca Inv. & BFL Prop., LLC Pasquotank County FOR THE construction, operation and maintenance of stormwater management systems in compliance with the provisions of 15A NCAC 2H.1000 (hereafter referred to as the nstormwater rules") and the approved stormwater management plans and specifications and other supporting data as attached and on file with and approved by the Division of Water Quality and considered a part of this permit for (3) wet detention ponds to serve Winchester Station located at Elizabeth City, NC. This permit shall be effective from the date of issuance until December 23, 2006, and shall be subject to the following specified conditions and limitations: I. DESIGN STANDARDS 1. This permit is effective only with respect to the nature and voluAe of stormwater described in the application and other supporting data. 2. This stormwater system has been approved for the management of stormwater runoff as described on pages 4 and 5 of this permit, the Project Data Sheet(s). 3. Approved plans and specifications for this project are incorporated by reference and are enforceable parts of the permit. 3 DIVISION OF WATER QUALITY PROJECT DATA Project Name: Permit Number: Location: Applicant: Mailing Address: Application Date: Water Body Receiving Stormwater Runoff: Classification of Water Body: Pond/Basin Depth: Permanent Pool Elevation: Total Site Area: Total Impervious Surfaces Allowed: Required Surface Area (SA/DA): Provided Surface Area: 4 Winchester Station SW7960912 Pasquotank County West Seneca Inv. & BFL Prop., LLC c/o Arthur Bergman 204 Binnacle Court Elizabeth City, NC 27909 9/26/96; original 11/1/96; complete Knobbs Creek C A - 4.5 feet B - 5.0 feet C - 4.0 feet A - 7.0 ft MSL B - 7.6 ft MSL C - 7.5 ft MSL 3.12 acres 1.65 acres A - 1648 square feet B - 1338 square feet C - 902 square feet A - 2048 square feet B - 1430 square feet C - 902 square feet Required Storage volume: Provided Storage volume: Controlling Orifice: 6084 cubic feet total 8319 cubic feet total 0.75 inch orifice pipe A & B; 0.50 inch orifice pipe C 4. No homeowner/lot owner/developer shall be allowed to fill in, alter, or pipe any vegetative practices ( such as swales ) shown on the approved plans as part of the stormwater management system without submitting a revision to the permit and receiving approval from the Division. 5. The following items will require a modification to the permit: a. Any revision to the approved plans, regardless of size b. Project name change C. Transfer of ownership d. Redesign or addition to the approved amount of built -upon area e. Further subdivision of the project area. In addition, the Director may determine that other revisions to the project should require a modification to the permit. 6. The Director may notify the permittee when the permitted site does not meet one or more of the minimum requirements of the permit. Within the time frame specified in the notice, the permittee shall submit a written time schedule to the Director for modifying the site to meet minimum requirements. The permittee shall provide copies of revised plans and certification in writing to the Director that the changes have been made. II. SCHEDULE OF COMPLIANCE 1. The permittee will comply with the following schedule for construction and maintenance of the stormwater management system. a. The stormwater management system shall be constructed in its entirety, vegetated and operational for its intended use prior to the construction of any built -upon surfaces except roads. b. During construction, erosion shall be kept to a minimum and any eroded areas of the system will .be repaired immediately. F1 2. The facilities must be properly maintained and operated at all times. The approved Operation and Maintenance Plan must be followed in its entirety and maintenance must occur at the scheduled intervals. 3. The permittee shall at all times provide the operation and maintenance necessary to assure the permitted stormwater system functions at optimum efficiency including, but not limited to: a. Semiannual scheduled inspections (every 6 months) b. Sediment removal C. Mowing and revegetation of side slopes d. Immediate repair of eroded areas e. Maintenance of side slopes in accordance with approved plans and specifications f. Debris removal and unclogging of outlet structure, orifice device and catch basins and piping. 4. Records of maintenance activities must be kept and made available upon request to authorized personnel of DWQ. The records will indicate the date, activity, name of person performing the work and what actions were taken. 5. This permit shall become voidable unless the facilities are constructed in accordance with the conditions of this permit, the approved plans and specifications, and other supporting data. 6. Upon completion of construction and prior to operation of this permitted facility, a certification must be received from an appropriate designer for the system installed certifying that the permitted facility has been installed in accordance with this permit, the approved plans and specifications, and other supporting documentation. Mail the Certification to the Washington Regional Office, 1424 Carolina Avenue, Washington, North Carolina, 27889, attention Division of Water Quality. 7. A copy of the approved plans and specifications shall be maintained on file by the Permittee for a minimum of five years from the date of the completion of construction. III. GENERAL CONDITIONS 1. This permit is not transferable. In the event there is a desire for the facilities to change ownership, or there is a name change of the Permittee, a formal permit request must be submitted to the Division of Water Quality accompanied by an application fee, documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request will be considered on its merits and may or may not be approved. 0 2. Failure to abide by the conditions and limitations contained in this permit may subject the Permittee to enforcement action by the Division of Water Quality, in accordance with North Carolina General -Statute 143-215.6(a) to 143-215.6(c). 3.. The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction. 4. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement stormwater management systems. 5. The permit may be modified, revoked and reissued or terminated for cause. The filing of a request for •a permit modification, revocation and reissuance or termination does not stay any permit condition. Permit issued this the 23 rd day of December, 1996. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION W ` 'fC,Z' A. Preston Howa d, Jr., P.E., Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number SW7960912 7 Winchester Station Mr. Arthur Bergman Pasquotank County Stormwater Permit No.-SW7960912 Designer's Certification 2, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (periodically/weekly/full time) the construction of the project, for (Project) (Project Owner) hereby state that to the best of my abilities, due care and diligence was used in the observation of the project construction such that the construction was observed to be built within substantial compliance and intent of the approved plans and specifications. Signature Registration Number Date 8 State of North Carolina Department of Environment, Health and Natural Resources Washington Regional Office JameS S. Hunt, Jr., Governor Jonathan B. Howes, Secretary West Seneca Inv., Attn: Mr. Arthur 204 Binnacle Court Elizabeth City, NC Dear Mr.Bergman: �EHNR IN ECEIVRD DIVISION OF WATER QUALITX WASHGTON OFFICE October 29, 1996 NOV o Z 1996 LLC Bergman flM. 27909 Subject: Application No. SW7960912 Winchester Station Pasquotank County The Washington Regional Office acknowledges receipt of your stormwater application and supporting information on September 26, 1996. This application has been assigned the number listed above. A preliminary review of your project has been completed. The following additional information is needed before a permit can be issued: -- stormwater runoff calculations - narrative description of stormwater control measures - signed operation and maintenance agreement •/ The above information must be submitted within.30 days, or your application will be returned as incomplete. If you have questions, please feel free to contact me at (919) 946-6481, extension 264. Sincerely, William J. ore Environmental Engineer Washington Regional Office cc: x,4bey Associates Washington Regional Office 1424 Carolina Avenue, Washington, NC 27889 Telephone (919) 946-6481 FAX (919) 975-3716 An Equal Opportunity Affirmative Action Employer 50% recycled / lo% post -consumer paper ROBEY ASSOCIATES ENGINEERING CIVIL - SANITARY SEAN G ROBEY, P.E. Office (919) 335-1888 Fur (919) 338-9888 September 20, 1996 Mr. Bill Moore Dept. of Natural Resources and Community Development Water Quality Section 1424 Carolina Avenue = - P.O. Box 1502 w.�sxrn r 11vvr:f; � Washington, NC 27889 UP 2 6 1996 Subject: Stormwater Exemption Application Winchester Station Proj. 4360 Dear Mr. Moore: Enclosed for your review and approval, please find the following items: I . Two (2) copies of the "Streets, Grading and Sediment & Erosion Control Plan", Sheet 2 and 6, of 6. 2. Two (2) copies of the Stormwater Exemption Application. 3. Check in the amount of $385.00 for the required fee. Please note a sedimentation and erosion control plan has been submitted as of this date. If you have any questions, please'do not hesitate to call. Sincerely, Y k sA .502-4- (L `l Sean C. Robey, P.E. cc: Mr. Arthur Bergman Mr. Gary Filarecki rile enclosure(s) Mailing Address: P. O. Box 2705 Elizabeth City, NC 27906-2705 Office : 523 S. Hughes Blvd. Elizabeth City, NC 27909 WASHINGTON OFF[CE DIVISION OF ENVIROKKE'� Nar• MANAGEMENT ;SEP 2 6.1996 NORTH CAROLINA STORMWATER MANAGEMENT PERMIT APPLICATION I. GENERAL INFORMATION: 1. Project Name: Winchester Station 2. Project Location: (County, State Road, address) _Rasauatank QQunty SR 1152 - Halstead Blvd. Elizabeth CitX, NC 3. Owner'sName:West Seneca Inv.,LLC & BFL Prop., LLCPhone: 338-6519 4. Mailing Address: �� 4 Binnacle Court City Elizabeth City State NC Zip 27909 5. Application Date: Aug. 8, 1996 Fee Submitted: $385 . 00 7. Nearest Receiving Stream: Knohbs Creek class: C SW S. Project Description: Commercial complex containing 29 units intended primarily for office use. II. PERMIT INFORMATION 1. Permit No. (will be completed by DEM) : SW `Q e" 9 — 2. Permit Type: XX New Renewal Modification (existing permit no.) 3. Project Type: Low Density XX Detention Infiltration Other 4. Other State/Federal Permits/Approvals Required: (Check appropriate blanks) XX Sediment/Erosion Control LAMA Major XX 404 Permit III. PROJECT BUILT UPON AREA Drainage Drainage Basin Basin Breakdown of Impervious Areas Classification Q SW Buildings 0.59 Ac Allowable Impervious 30% :toads Total Project Area 1.12 Ar, Parking 1.06 Ac Proposed Impervious 1.65 AC Other $ Impervious Area 5 2 . 9% Totals 1.65 Ac IV. sTORMWATER TREAZKENT (Describe how runoff will be treated): Starmwdter is cQllected through a combination of gra5s lined swales with 3_:1 side slopes and an underground collection system and then routed to one of three detention ponds. V. DEED RESTRICTIONS AND PROTECTIVE COVENANTS Deed restrictions and protective covenants are required for all low density projects and all subdivisions prior to. the sale of any lot. Please see attachment A for specific reauirements . By your signature below, you certify that the recorded deed restrictions and protective covenants for this project shall include all the items required by the permit, that the covenants will be binding on all parties and persons claiming under them, that they will run with the land, that the covenant cannot be changed or deleted without concurrence from the State, and that they will be recorded prior to the sale of any lot. OWNER'S CERTIFICATION I, Arthur Bergman _ certify that the (Please print name clearly) information included on this permit application form is correct, that the project will be constructed in conformance with the approved plans, that the deed restrictions will be recorded with all required permit conditions, and that to the best of my knowledge, the proposed project complies with the requirements of 15A NCAC 2H.1000. Y authorize the behalf k-4 /t, owner /Authorrri/zec AUTHORIZED AGENT below named person or firm to submit stormwater plans on my t e /S^ /6 Date Person or Firm Name: t1 C.Robev-, p.E.___Robey Associates Enaineering Mailing Address: p . 0. Box 2705 City Elizabeth City state NC zip 27906 Phone: ( 919 ) 335-1888 Please summit application, fee and plans to appropriate Regional Office. (see attached map) -2- DIVISION OF ENVIRONWENTAL MANAGEMENT NORTH CAROLINA STORMWATER MANAGEMENT PERMIT APPLICATION GENERAL INFORMATION: 1. Project Name: Winchester Station $EC£IVE;D WASH"'T i-ON OFFICE NOV 0 1 1996, 2. Project Location: (County, State Road, Address) Pasguotank__C9unty SR 1152 - Halstead Blvd. Elizabeth Citv, NC D. E. M. 3. Owner's Name -West Seneca Inv. ,LLC & BFL Prop. , LLCPhone: 338-6519 4. Mailing Address: 20A Binnacle Count. — City Elizabeth City State NC zip 27909 5. Application Date: Aug. 8, 1996 Fee Submitted: $385.00 7. Nearest Receiving Stream: Knobbs Creek Class: C Sw 8. Project Description: Commercial complex_ containing 29 units intended primarily for office use. II. PERMIT INFORMATION 1. Permit No. (will be completed by OEM) : SLC) �Y& ram_ 2. Permit Type: XX New Renewal Modification (existing permit no.) 3. Project Type: Low Density XX Detention Infiltration Other 4. Other State/Federal Permits/Anprovals Required: (Check appropriate blanks) XX Sediment/Erosion Control CAMA Major XX 404 Permit III. PROJECT BUILT UPON AREA Drainage Drainage Basin aasin Classification C SW Allowable Impervious 30% Total Project Area 3.12 Ac Proposed Impervious 1.65 Ac % Impervious Area 52.9% Breakdown of Imner7lous Areas Buildings 0.59 Ac Roads Parking 1.06 Ac Other Totals 1.65 AC IV. STORMWATER TREAT24E?T (Describe how runoff will be treated): Starmwater ia collected through a combinat' of s ned swales with 3:1 side slopes and an underground collection system and then routed to one of three detention ponds. V. DEED RESTRICTIONS AND PROTECTIVE COVENANTS Deed restrictions and protective covenants are required for all low density projects and all subdivisions prior to the sale of any lot. Please see Attachment A for sneciEic reauirements. By your signature below, you certify that the recorded deed restrictions and protective covenants for this project shall include all the items required by the permit, that the covenants will be binding on all parties and persons claiming under them, that they will run with the land, that the covenant cannot be changed or deleted without concurrence from the State, and that they will be recorded prior to the sale of any lot. OWNER'S CERTIFICATION I, _Arthur Bergman _ certify that the (Please print name clearty) information included on this permit application form is correct, that the project will be constructed in conformance with the approved plans, that the deed restrictions will be recorded with all required permit conditions, and that to -the best of my knowledge, the proposed project complies with the requirements of 15A NCAC 2H.1000. T authorize the below named person or firm to submit stormwater plans on my behalf. 7Z_ 2 Owner/Authorized Aqe t Signature and Title Date AUTHORIZED AGENT Person or Firm game: Span C. RQbey, P.E.obe Associates Engineering Mailing Address: p . 0. BOX 2705 City Elizabeth CitX state NC zip 27906 Phone: (919) 335-1888 Please submit application, fee and plans to appropriate Regional Office. (see attached map) -2- ROBEY ASSOC4TES ENGINEERING 1VIL - SEAN G ROBEY, P.E: Office (919) 335-1888 Fax (919) 338-9888 �► NIIWiZ►M M Project Description Winchester Station is a proposed commercial complex consisting of 29 townhouse style office buildings in Elizabeth City, NC. The project is located on SR 1152 - Halstead Blvd approximately 350 ft southeast of the intersection of Walkers Avenue and Halstead Blvd. in Pasquotank County. The project is located beside Guardian Care Nursing Horne on the north, a vacant parcel on the south and wetland area on the west. A wetland delineation has been performed on the site and 'Mi. Henry Wicker of the U.S. Army Corps of Engineers has approved the delineated line. Drainage for the site is directed into one of three detention ponds located onsite. The detention ponds discharge to the wetland area via grassed swales with rip -rap outlet protection. The wetland area is the floodway of a large tributary of Knobbs Creek. The disturbed area for the site is 2.59 AC., which is all land above the 404 wetland delineation line. The proposed built upon area for the complex is 1.65 AC., which consists of 0.59 AC. of building and 1.06 AC. of parking and sidewalk. Therefore the resultant built -upon area is 52.9%. Mailing Address: P. O. Box 2705 Elizaberh Cirv, NC 27906-2705 Office : 523 S. Hughes Blvd. Elizaberh City, NC 27909 TR-55 GRAPHICAL DISCHARGE METHOD VERSION 1.11 Project WINCHESTER STATION User: SCR Date: 08-21-96 County PASQUOTANK State: NC Checked: Date: Subtitle: DETENTION POND A RECEW}��1� NG7'OIVED N�OFFfCE Data: Drainage Area .86 * Acres Runoff Curve Number 92 * NOV U 1 1996 Time of Concentration: 0.52 * Hours Rainfall Type II Pond and Swamp Area NONE �, E. M. Storm Number 1 2 3 4 5 6 7 ---------------------- ------ ------ ------ ------ ------ ------ ------ Frequency (yrs) 1 2 5 10 25 50 100 24-Hr Rainfall (in) 3.5 4 5.5 6.3 7.1 8.3 9.1 Ia/P Ratio 0.05 0.04 0.03 0.03 0.02 0,02 0.02 Used 0.10 0.10 0.10 0.10 0.10 0.10 0.10 Runoff (in) 2.64 3.12 4.58 5.36 6.15 7.34 8.13 ,Unit Peak Discharge 0.810 0.810 0.810 0.810 0.810 0,810 0.810 (cfs/acre/in) Pond and Swamp Factor 1.00 1.00 1.00 1.00 1.00 1,00 1.00 0.00i Ponds Used Peak Discharge {cfs) 2 1 2 3 1 4 1 4 5 6 * - Value(s) provided from TR-55 system routines ✓ o�, f'P Alov r ,) SA Pam. Ar 7 r op, TR-55 CURVE NUMBER COMPUTATION VERSION 1.1 Project WINCHESTER STATION User: SCR Date: 08-21-96 County PASQUOTANK State: NC Checked: Date: Subtitle: DETENTION POND A Subarea : 0.86 ------------------------------------------------------------------------------- Hydrologic Soil Group COVER DESCRIPTION A B C D Acres (CN) ------------------------------------------------------------------------------- FULLY DEVELOPED URBAN AREAS (Veg Estab.) Open space (Lawns,parks etc.) Good condition; grass cover > 750 - - .21(74) - Impervious Areas Paved parking lots, roots, driveways Total Area (by Hydrologic Soil Group) LBD ------------------------------------------------------------------------------- SUBAREA: 0.86 TOTAL DRAINAGE AREA: .86 Acres WEIGHTED CURVE NUMBER:92* ------------------------------------------------------------------------------- * - Generated for use by GRAPHIC method TR-55 Tc and Tt THRU SUBAREA COMPUTATION VERSION 1.11 Project WINCHESTER STATION User: SCR Date: 08-21-96 County PASQUOTANK State: NC Checked: Date: Subtitle: DETENTION POND A ------------------------------------------------------------------------------- Flow Type 2 year Length Slope Surface n Area Wp Velocity Time rain (ft) (ft/ft) code (sq/ft) (ft) (ft/sec) (hr) ------------------------------------------------------------------------------- Sheet 4 150 .005 F 0.512 Shallow Concent'd 50 .01 P 0.007 Time of Concentration = 0.52* --- Sheet Flow Surface Codes --- A Smooth Surface F Grass, Dense B Fallow (No Res.) G Grass, Surmuda C Cultivated < 20 o Res. H Woods, Light D Cultivated > 20 o Res. I Woods, Dense E Grass -Range, Short * - Generated for use by GRAPHIC method --- Shallow Concentrated --- - -- - Surface Codes - - - P Paved U Unpaved PERMANENT POOL DETENTION PONDS Robey Associates Engineering DESIGN OF POND P. 0. Box 2705 Elizabeth Citv. NC 27909 Winchester Station (919)-335-1888 10 Yr, 24 Hr Storm 08/21 /96 DETENTION POND "A" Pale 1 SA/DA PERCENTAGES FOR 85% TSS REMOVAL WITH 30' VEGETATIVE FILTER % 11APRV 3.0 FT 3.5 FT 4.0 FT 4.5 FT 5.0 FT 5.5 FT 6.0 FT 6.5 FT 7.0 FT 7.5 FT 10% 0.9 0.8 0.7 0.6 0.5 20% 1.7 L3 1.2 1.1 1.0 0.9 0.8 0.7 0.6 0.5 30% 2.5 2.2 1.9 l.8 1.6 1.5 i.3 1? 1.0 0.9 40% 3.4 3.0 2.6 2.4 2.1 1,9 1.6 1.4 1.1 1.0 50% 42 3.7 3.3 3.0 2.7 2.4 2.1 1.8 1.5 1.3 60% 5.0 4.5 3.8 3.5 32 19 2.6 2.3 2.0 i.6 70% 6.0 5.2 4.5 4.1 3.7 3.1 2.9 2.5 2.1 1.8 80% 6.8 6.0 5.2 4.7 4.2 3.7 3.2 2.7 2.2 2.0 90% 7.3 6.5 5.8 5.3 4.8 4.3 3.8 3.3 2.8 2.3 100% 8.2 T4 6.8 6.2 5.6 5.0 4A 3.8 3.2 2.6 WATERSHED AREA: 0.86 ACRES WATERSHED % IMPERVIOUS: 76 0/- PERMANENT POOL ELEVATION: 7 FT DESIGN PERMANENT POOL DEPTH: 4.5 FT SA/DA PERCENTAGE FACTOR: 4.4 % {FROM ABOVE TABLE -TAKEN FROM DES[GN OF STORM WATER ' CONTROL FACILITIES WORKSHOPMANUAL - PE. IC 1988) POND SURFACE AREA REQ'D: 1648 SF J• FOREBAY AREA: 330 SF AT WIDTH = 0.5 LENGTH, WIDTH = 28.7081 LF (BASED UPON MINIMUM SURFACE AREA) LENGTH = 57.4162 LF Use these dimensions: WIDTH 32 LF LENGTH 64 LF VOLUME OF I" RAINFALL AREA OF ROOFS: 0.28 AC AREA OF PARKING/CONCRETE: 0.37 AC AREA OF GREEN AREAS: 0.21 AC VOLUME OF RUNOFF / 2444- 8F-, STORAGE DEPTH FOR MINIMUM AREA = ELEVATION OF I" RAINFALL = 8.19 Normal Pool Elevation 7 VOL (CF)=[(ROOF*1.0)+(PARKING*.95)+(GRASS*0.2}]*43,560/12 L l9 FT DRAWDOWN - WATER QUALITY Q(2 DAYS) = 0.01415 CFS Q(5 DAYS) = 0,00566 CFS l" RUNOFF STAGE 1.19 FT DEPTH OF DRAWDOWN DEVICE BELOW OUTLET 1.5 FT I" RUNOFF OUTLET DEVICE: 0.69866 INCH DIA DOLE A={Q/(Cd*SQRT(2vh))]* 144 Rad.=SQRT(A/Pl) � Dia.=2*Rad. DIAMETER OF HOLE TO USE: �0.751i��i DIAMETER / i" STORM RUNOFF DRAWDOWN TIME 2.479;�DA�S 11 INFLOW HYDROGRAPH Return Year Storm 10 Yr Qp = Peak Discharge = 4 cfs Tc = Time fo Concentration = 30 min Calculation of Tp (Time to Peak) From SCS NEH 4 , pace 15-7 Eqn. 15.4 Las Time (L) _ (1^0.8*(Sfl)^0.7)/(1900*Y^0.5) for Lin Hrs where: 1 = hydraulic length of watershed (ft) S = (l 000/CN)-10 CN = approximately same CN from TR-55 Y = avg. watershed land slope in % S = (1000/CN)-10 = 0,86957 L= 0.07553 hrs From SCS NEH 4, page 16-7 Eqn. 16.7 Tp=D/2-L where : D = unit of excess duration rainfall (hrs) L = Lag Time (hrs) From SCS NEH 4 page 16-8 Eqn, 16.12 D 0.133 tc where: Tc = Time of Concentration (hrs) - (See Tr-55 Printout) THEREFORE: D = 0.0665 hrs Tp = 0.10879 hrs = 6.52663 min Volume under Hydrograph = 1.39 * Qp * Tp = 2177.28 Cubic Feet Page 2 240 ft 0.86957 92 0.75 % Inflow Hydrograph SCS Dimensionless Hydrograph Time Discharge Time Discharge Volume Ratio Ratio hr cts cf 0.00 0.00 0.00 0.10 0.03 0.01 0.20 0.10 0.02 0.30 0.19 0.03 0.40 0.31 0.04 0.50 0.47 0.05 0.60 0.66 0.07 0.70 0.82 0.08 0.80 0.93 0.09 0.90 0.99 0.10 1.00 1.00 0,11 1.10 0.99 0.12 1.20 0.93 0.13 1.30 0.86 0.14 1.40 0.78 0.15 1.50 0.68 0.16 1.60 0.56 0.17 1.70 0.46 0.18 1.80 0.39 0.20 1.90 0.33 0.21 2.00 0.28 0.22 2.20 0.21 0.24 2.40 0.15 0.26 2.60 0.11 US 2.80 0.08 0.30 3.00 0.06 0.33 3.20 0.04 0.35 3.40 0.03 0.37 3.60 0.02 0.39 3.80 0.02 0.41 4.00 0.01 0.44 4.50 0.01 0.49 5.00 0.00 0.54 Volume under hydrograph = 0 0 0 I l 2 3 3 4 4 4 4 4 3 3 3 2 2 2 l l 1 1 0 0 0 0 0 0 0 0 0 0 16 30 49 74 103 128 146 155 157 155 146 135 122 M 88 72 61 52 44 65 46 34 24 17 13 9 7 5 3 4 0 2068 of Page 3 Based upon runoff volume = 2177.28 cf Depth req'd for minimum area = 1.06313 ft STAGE STORAGE FUNCTION OF POND Page 4 (FOR RECTANGULER DETENTION POND ONLY) Pond Side Slope (M) = 3 Minimum surface area taken at normal water level BASIN AREA INCR ACCUM VOLUM VOLUM STAGE In s In Z Z est Elevation S Z sf cf cf ft 2048 0 0 0 Surface area at normal pool 7 2345 1098 1098 0.5 7.00 -0.69 0.49 7.5 2660 1251 2350 1 7.76 0.00 0.96 8 V0� �(ar 2993 1413 3763 1.3 8.23 0.41 1.44 D 144S �. 3344 1584 5347 2 8.58 0.69 1.95 9 3713 1764 7111 2.5 8.87 0.92 2.50 9.5 4100 1953 9065 3 9.11 1.10 3.09 l0 4505 2151 11216 3.5 9.33 1.25 3.71 10.5 4928 2358 13574 4 9.52 1.39 4.38 11 5369 2574 16148 4.5 9.69 1.50 5.09 11.5 5828 2799 18948 5 9.85 1.61 5.85 12 Regression Output: Constant 9.34346 Ks = S/Z^b = 2474.34 Std Err of Y Est 0.00969 R Squared 0.99962 No. of Observations 7 Degrees of Freedom 5 X Coefficient(s) L 15215 = b Std Err of Coef. 0.01009 FOR VERTICAL SIDED DETENTION POND SET b=0, AND Ks = SURFACE AREA (SF) STAGE DISCHARGE (FOR RISERIBARRELL SPILLWAY W EMERGENCY WEIR) RISER Dr = 30 Riser Dia. (in) Etop = 8.25 Elev. Top Riser (ft) 8.06 Cwr - 3.33 Riser weir coeff Cdr = 0.60 Riser orifice coeff H l n = 0 Number of Holes Hld _ 0 Hole Dia. (in) EHI - 15.00 Elev. Holes (1) 1-12n = 0 Number of Holes H2d = 2 Hole Dia. (in) EH2 = 15.00 Elev. Holes (2) Han = 0 Number of Holes Had = 2 Hole Dia. (in) EH3 = 15.00 Elev. Holes (3) BARREL: Db = 15 Barrel Dia. (in) Einv = 7.00 Elev Invert Barrel (ft) Barrell Adjustment Factor 0 Cdb = 0.60 Barrel orifice coeff EMERGENCY WEIR Page 5 Cw - 3 Weir coeff Ecr - 1 5.00 Elev weir coeff (ft) Lw - 20 Weir Len-th (ft) Riser Riser Riser Elevation Hole Hole Hole Riser Riser Barrel Principal EmerFcv Total (1) (2) (3) (weir) (orifice) Spillway Weir Outflow 7.00 0.0 0.0 0.0 0.0 0.0 0.0 0.00 0.0 0.00 7.00 0.0 0.0 0.0 0.0 0.0 0.0 0.00 0.0 0.00 7.00 0.0 0.0 0.0 0.0 0.0 0.0 0.00 0.0 0.00 7.02 0.0 0.0 0.0 0.0 0.0 0.0 0.00 0.0 0.00 7.03 0.0 0.0 0.0 0.0 0.0 0.0 0.00 0.0 0.00 7.06 0.0 0.0 0.0 0.0 0.0 0.1 0.00 0.0 0.00 7.10 0.0 0.0 0.0 0.0 0.0 0.1 0.00 0.0 0.00 7.15 0.0 0.0 0.0 0.0 0.0 0.2 0.00 0.0 0.00 721 0.0 0.0 0.0 0.0 0.0 0.3 0.00 0.0 0.00 7.27 0.0 0.0 0.0 0.0 0.0 0.5 0.00 0.0 0.00 7.34 0.0 0.0 0.0 0.0 0.0 0.7 0.00 0.0 0.00 7.40 0.0 0.0 0.0 0.0 0.0 0.8 0.00 0.0 0.00 7.46 0.0 0.0 0.0 0.0 0.0 1.1 0.00 0.0 0.00 7.52 0.0 0.0 0.0 0.0 0.0 1.3 0.00 0.0 0.00 7.57 0.0 0.0 0.0 0.0 0.0 1.4 0.00 0.0 0.00 7.62 0.0 0.0 0.0 0.0 0.0 1.6 0.00 0.0 0.00 7.66 0.0 0.0 0.0 0.0 0.0 1.8 0.00 0.0 0.00 7.69 0.0 0.0 0.0 0.0 0.0 1.9 0.00 0.0 0.00 7.72 0.0 0.0 0.0 0.0 0.0 2.0 0.00 0.0 0.00 7.74 0.0 0.0 0.0 0.0 0.0 2.1 0.00 0.0 0.00 7.76 0.0 0.0 0.0 0.0 0.0 2.2 0.00 0.0 0.00 7.79 0.0 0.0 0.0 0.0 0.0 2.4 0.00 0.0 0.00 7.81 0.0 0.0 0.0 0.0 0.0 2.5 0.00 0.0 0.00 7.83 0.0 0.0 0.0 0.0 0.0 2.5 0.00 0.0 0.00 7.84 0.0 0.0 0.0 0.0 0.0 2.6 0.00 0.0 0.00 7.85 0.0 0.0 0.0 0.0 0.0 2.6 0.00 0.0 0.00 7.86 0.0 0.0 0.0 0.0 0.0 2.7 0.00 0.0 0.00 7.96 0.0 0.0 0.0 0.0 0.0 2.7 0.00 0.0 0.00 7.86 0.0 0.0 0,0 0.0 0.0 2.7 0.00 0.0 0.00 7.87 0.0 0.0 0.0 0.0 0.0 2.7 0.00 0.0 0.00 7.87 0.0 0.0 0.0 0.0 0.0 2.7 0.00 0.0 0.00 7.87 0.0 0.0 0.0 0.0 0.0 2.7 0.00 0.0 0.00 7.87 0.0 0.0 0.0 0.0 0.0 2.7 0.00 0.0 0.00 Page 6 ROUTING OF INFLOW HYDROGRAPH THROUGH POND AND OUTFLOW DEVICE Total Riser Riser Riser Barrel Enierg Time Inflow Storage Stage Outflow Holes (weir) (orifice) Spillway t(hr) cfs cf Elevation cfs (1-'2-3) cfs cfs cfs cfs cfs 0.000 0 0 7.00 0.00 0.00 0.00 0.00 0.00 0.00 0.011 0 0 7.00 0.00 0.00 0.00 0.00 0.00 0.00 0.022 0 4.69917 7.00 0.00 0.00 0.00 0.00 0.00 0.00 0.033 1 20.3631 7.02 0.00 0.00 0.00 0.00 0.01 0.00 0.044 1 50.1245 7.03 0.00 0.00 0.00 0.00 0.02 0.00 0.054 2 98.6826 7.06 0.00 0.00 0.00 0.00 0.05 0.00 0.065 3 172.303 7.10 0.00 0.00 0.00 0.00 0.10 0.00 0.076 3 275.685 7.15 0.00 0.00 0.00 0.00 0.19 0.00 0,087 4 404.129 7.21 0.00 0.00 0.00 0.00 0.32 0.00 0.098 4 549.803 7.27 0.00 0.00 0.00 0.00 0.47 0.00 0.109 4 704.876 7.34 0.00 0.00 0.00 0.00 0.65 0.00 0.120 4 861,515 7.40 0.00 0.00 0.00 0.00 0.85 0.00 0.131 4 1016.59 7.46 Mo 0.00 0.00 0.00 1.05 0.00 0.141 3 1162.26 7.52 Mo 0.00 0.00 0.00 1.25 0.00 0.152 3 1296.97 7.57 0.00 0.00 0.00 0.00 1.44 0.00 0.163 3 1419.15 7.62 0.00 0.00 0.00 0.00 1.62 0.00 0.174 2 1525.67 7.66 0.00 0.00 0.00 0.00 1.78 0.00 0.185 2 1613.38 7.69 0.00 0.00 0.00 0.00 1.92 0.00 0.196 2 1685.44 7.72 0.00 0.00 0.00 0.00 2.03 0.00 0.207 1 1746.53 7.74 0.00 0.00 0.00 0.00 2.13 0.00 0.218 1 1798.22 7.76 0.00 0.00 0.00 0.00 2.21 0.00 0.239 1 1885.94 7.79 0.00 0.00 0.00 0.00 2.35 0.00 0,261 l 1950.78 7.81 0.00 0.00 0.00 0.00 2.46 0.00 0.283 0 1996.84 7.83 0.00 0.00 0.00 0.00 2.53 0.00 0.305 0 2030.36 7.84 0.00 0.00 0.00 0.00 2.59 0.00 0.326 0 2054.48 7.85 0.00 0.00 0.00 0.00 2.63 0.00 0.348 0 2071.71 7.86 0.00 0.00 0.00 0.00 2.66 0.00 0.370 0 2084.24 7.86 0.00 0.00 0.00 0.00 2.68 0.00 0.392 0 2093.33 - 7.86 0.00 0.00 0.00 0.00 2.69 0.00 0.413 0 2099.9 7.87 0.00 0.00 0.00 0.00 2.70 0.00 0.435 0 2104.6 7.87 0.00 0.00 0.00 0.00 2.71 0.00 0.489 0 2113.22 7.87 0.00 0.00 0.00 0.00 2.73 0.00 0.544 0 2117.13 7.87 0.00 0.00 0.00 0.00 2.73 0.00 7.87343 = maximum stage elevation 0 = maximum discharge 4 4 3 3 m rn 2 (U in L U 2 L 1 0 d(4 0.000 A Chart 1 Proposed Site for Winchester Station - Pond "A" Elizabeth City, NC 10 yr STORM 0.100 0.200 0.300 0.400 0.500 Time (hrs) 0.600 ■ ' INFLOW (cfs) i OUTFLOW (cfs) Page 1 state of North Carolina Department of Environment, Health and Natural Resources Washington Regional office James S. Hunt, Jr., Governor Jonathan B. Howes, Secretary West Seneca Inv., Attn: Mr. Arthur 204 Binnacle Court Elizabeth City, NC Dear Mr.Bergman: DIVISION OF WATER QUALITY October 29, 1996 LLC Bergman 27909 Subject: Application No. SW7960912 Winchester Station Pasquotank County The Washington Regional Office acknowledges receipt of your stormwater application and supporting information on September 26, 1996. This application has been assigned the number listed above. A preliminary review of your project has been completed. The following additional information is needed before a permit can be issued: stormwater runoff calculations narrative description of stormwater control measures - signed operation and maintenance agreement The above information must be submitted within. 30 days, or your application will be returned as incomplete. If you have questions, please feel free to contact me at (919) 946-6481, extension 264. Sincerely, William J. ore Environmental Engineer Washington Regional Office cc: Robey Associates ,,Washington Regional Office 1424 Carolina Avenue, Washington, NC 27889 Telephone (919) 946-6481 FAX (919) 975-3716 An Equal Opportunity Affirmative Action Employer 50% recycled / 10% post -consumer paper