Loading...
HomeMy WebLinkAboutSW7960108_HISTORICAL FILE_20060502STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW DOC TYPE ❑CURRENT PERMIT ❑ APPROVED PLANS HISTORICAL FILE DOC DATE - �F1B�o05vi YYYYMMDD OF W q�9 L,( d jam; �Lf�i¢C .5`3� (P Michael F. Easley, Governor G William G. Ross, Jr., Secretary MAY 0 2 2006 North Carolina Department of Environment and Natural Resources Z. Alan W. Klimek, P.E. Director Q-WA RO r. Division of Water Quality SURFACE WATER PROTECTION SECTION COASTAL STORMWATER PERMIT RENEWAL APPLICATION FORM I. CURRENT PERMIT INFORMATION: 1. Stormwater Management Permit Number:.. 2. Permit Holder's name: --57 e 4144 C 3. Signing official's name. Title: (person legally responsible for permit) 4. Mailing address: 24 City: Stater ZipCode: D Phone: ll/ FAX: (Area Code and Number) Area de and Number) 5. Project Name: 4% odld- TzTO1.L 6. Location of Project: (street address) q42Z 11,q L67Z:A D Lll.E4&D _ ,EkL46 &rA Ci a , 6 92 7. Directions to Project (from nearest major intersection) 1 ,c v► , o R AAID ilut<#L& ;BWD, TE#WAU!DA. A[isTif .,2lBasGVA-Sr, 96 PERM T INFORMATION 1. Specify the type of stormwater treatment (wet pond, infiltration, etc.): 2. List any changes (from project that was originally approved, attach additional pages if needed) /Y UNf 3. Do you have a copy of the original Operation and Maintenance Agreement? Yes" o Applicant's Certification: 1, (print) Y , certify that the information included on this permit r wal ap I' at' , is to t st of my knowledge, correct and complete. Signature: '' Date: D t r. Submit this complete�rm long wl Fi '�pIication fee of $420.00 and a copy of the designer's certification to the address listed below. North Carolina Division of Water Quality 943 Washington Square Mall Phone (252) 946- 481 Customer Service 1-877-623-6748 One Washington Regional Office Washington, NC 27889 FAX (252) 946-9215 Internet: h2o,enr.state.ne.us NofthCarollina An Equal Opportun4lAfEimnative Action Employer — 50% Recycled110% Post Consumer Paper AW114711lf o�0F WA7F,q Michael F. Easley, Governor William G. Ross Jr., Secretary rNorth Carolina Department of Environment and Natural Resources .� Alan W. Klimek, P.E. Director Division of Water Quality March 14, 2006 First investment Assoc. of Elizabeth City, LLC Attn: Mr. Richard Tharrington PO Box 7246 Rocky Mt, NC 27804 Subject: Stormwater Permit No. SW 7960108 Hampton Inn -Halstead Blvd Pasquotank Dear Mr. Richard Tharrington, The Division of Water Quality issued a Coastal Stormwater Management Permit, Number SW 7960108 to First Investment Associates of Elizabeth City for Hampton Inn -Halstead Blvd on 2/16/1996. This permit expires on 2/16/2006. Section .1003(h) of 15 A NCAC 2H .1000 (the stormwater rules) requires that applications for permit renewals shall be submitted 180 days prior to the expiration of a permit and must be accompanied by a processing fee, which is currently set at $420.00. If this is still an active project please complete and submit the enclosed renewal application in a timely manner. If this project has not been constructed and a permit is no longer needed, please submit a request to have the permit rescinded. If you have sold the project, or are no longer the permittee, please provide the name, mailing address and phone number of the person or entity that is now responsible for this permit. Enclosed is a form for change of ownership, which should be completed and submitted if the property has changed hands. Your permit requires that upon completion of construction and prior to operation of the permitted treatment units a certification of completion be submitted to the Division from an appropriate designer for the system installed. This is to certify that the permitted facility has been installed in accordance with the permit, the approved plans, specifications and supporting documentation. Please include a copy of the certification with your permit renewal request and processing fee. Enclosed is a copy of a sample certification. You should be aware that failure to provide the Designer's Certification and the operation of a stormwater treatment facility without a valid permit, are violations of NC General Statute 143-215.1 and may result in appropriate enforcement action including the assessment of civil penalties of up to $10,000 per day. If you have any questions, please feel free to contact me or a member of the coastal stormwater staff with DWQ at 252-946-6481, 7erely, et Al Hodge, Regional upervisor Surface Water Protection Section Washington Regional Office Enclosures cc: Hyman & Robey Washington Regional Office North Carolina Division of Water Quality Internet: %vvvw,ncwaterquality.or; One 943 Washington Square Mall Phone (252) 946.6481 No ,Karolina Washington, NC 27889 Fax (252) 946-9215 ;atutally An Equal Opportunity/Affirmative Actien Employer— 5C% Recycled/10% Post Consumer Paper WC, I to IT Michael F. Easley, Governor William G. Ross Jr,, Secretary North Carolina Department of Environment and Natural Resources July 17, 200E Mr. Richard Y. Tharrington First Investment Associates of Elizabeth City, LLC P.O. Box 7246 Rocky Mount, NC 27804 Subject: Stormwater Permit Renewal Review SW7960108 Hampton Inn — Elizabeth City Pasquotank County Dear Mr. Tharrington: Alan W. Klimek, P.E. Director Division of Water Quality This office received a Coastal Stormwater permit renewal application for the subject project on May 2, 2006. A preliminary review of your project and an onsite inspection indicates that before a State Stormwater permit can be issued the following additional information is needed: The stormwater pond now contains a fountain. Our Division has developed a policy for sizing fountains in stormwater ponds (copy enclosed). Please provide documentation that the fountain in this pond meets the criteria in the policy. 2. The onsite inspection revealed that are trees growing in the pond forebay. These should be removed and the pond and forebay depths should be checked and cleaned as needed. On the day of the inspection it was raining and a high volume of flow was leaving the pond. It appeared that the small diameter orifice that allows the 1-inch storm to be drawn in 2-5 days may not be there. Please confirm that the orifice in place. 4. Enclosed is a new operation and maintenance agreement form. Please complete the form, sign and return. The above requested information must be received in this office prior to August 17, 2006 or your applications will be returned as incomplete. The return of these projects will necessitate resubmittal of all required items including the application fees. If you need additional time to submit the required information, please mail or fax your request for time extension to this office at the Letterhead address. If you have questions, please feel free to contact me at (252) 948-3923. Sincerely, Roger K. Thorpe Environmental Engineer Washington Regional Office Enclosure cc: Hyman & Robey, PC with copy of,enclosure Washington Regional Office North Carolina Division of Water Quality Internet: wNvNN iic«atergLlalitn.orjz One 943 Washington Square Mall Phone (252) 946-6481 NorthCarohna Washington, NC 27889 Fax (252) 946-9215 Natu! iii�yrl� An Equal OpportunitylAfrmabve Action Employer-50% Recycled110% Post Consumer Paper Consulting Engineers and Land Surveyors (252) 335-1888 Office 150 A US Highway 158 East, Camden, NC 27921 (252) 338-2913 Office (252) 338-5552 Fax Transmittal JUN 202006 EwaNVARo Date 6/19/2006 TN -umber of pages including cover sheet NIA To Roger Thorpe Phone Dept, of Environment and Natural Resources 252.946.6481 Fax Land Quality Section 943 Washington Square Mall Washington, NC 27889 From Kimberly D. Hamby Phone (252) 335-1888 Project Manager kim@hymanrobey.com Fax (252) 338-5552 Subject/ 412 Sent Via mail Project # Hampton Inn Enclosures Copy of stormwater plans ' Please call For your review For your Approval X As you requested for further and comment discussion As we For your Files For your use Other discussed Message: Roger, I was able to find the vellums of the Hampton Inn plans. We didn't have blueprint paper sufficient to run full size blueprints, so each sheet has been copied in two pieces. I have only included the two sheets pertaining directly to stormwater. Please call if you need any additional information. Thank you, Kim State of North Carolina wf R--0 Department of Environment, Health and Natural Resources Washington Regional Office James B. Hunt, Jr., Governor Jonathan B. Howes, Secretary DIVISION OF ENVIRONMENTAL MANAGEMENT WATER QUALITY SECTION February 16, 1996 First Investment Associates of Elizabeth City, LLC Attn: Mr. Richard Y. Tharrington P.O. Box 7246 Rocky Mount, NC 27804 NJ F=1 Subject: Permit No. SW7960108 Hampton Inn Hotel -- Halstead Blvd High Density Stormwater Project Pasquotank County Dear Mr. Tharrington: The Washington Regional Office received the completed Stormwater Application for the subject project on January 31, 1996. Staff review of the plans and specifications has determined that the project, as proposed, will comply with the Stormwater Regulations set forth in Title 15A NCAC 2H.1000. We are forwarding Permit No. SW7960108 dated February 16, 1996 to First Investment Associates of Elizabeth City, LLC. This permit shall be effective from the date of issuance until February 16, 2006 and shall be subject to the conditions and limitations as specified therein. Please pay special attention to the Operation and Maintenance requirements in this permit. Failure to establish an adequate system for operation and maintenance of the stormwater management system will result in future compliance problems. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within thirty (30) days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings, P.O. Drawer 27447, Raleigh, NC 27611-7447. Unless such demands are made this permit shall be final and binding. 1424 Carolina Avenue, Washington, NC 27889 Telephone 919/946-6481 FAX 919/975-3716 An Equal Opportunity Affirmative Action Employer 50%recycled110%post-consumer paper �%k First Investment Associates of Elizabeth City, LLC February 16, 1996 Page Two If you have any questions, or need additional information concerning this matter, please contact Bill Moore at (919) 946- 6481, extension 264. Sincerely, f /I< Roger K. Thorpe Water Quality Supervisor Washington Regional Office cc: Robey & Associates P,asquotank County Inspections V"shington Regional Office Central Files :, State Stormwater Management Systems Permit No. SW7960108 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT, HEALTH AND NATURAL RESOURCES DIVISION OF ENVIRONMENTAL MANAGEMENT STATE STORMWATER MANAGEMENT PERMIT HIGH DENSITY DEVELOPMENT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO First Investment Associates of Elizabeth City, LLC Pasquotank County FOR THE construction, operation and' maintenance of stormwater management systems in compliance with the provisions of 15A NCAC 2H.1000 (hereafter referred to as the "stormwater rules") and the approved stormwater management plans and specifications and other supporting data as attached and on file with and approved by the Division of Environmental Management and considered a part of this permit for Hampton Inn Hotel, Halstead Blvd., Elizabeth City, NC. This permit shall be effective from the date of issuance until February 16, 2006, and shall be subject to the following specified conditions and limitations: I. DESIGN STANDARDS 1. This permit is effective only with respect to the nature and volume of stormwater described in the application and other supporting data. 2. This stormwater system has been approved for the management of stormwater runoff as described on pages 4 and 5 of this permit, the Project Data Sheet(s). 3. Approved plans and specifications for this project are incorporated by reference and are enforceable parts of the permit. 3 DIVISION OF ENVIRONMENTAL MANAGEMENT PROJECT DATA Project Name: Hampton Inn Hotel Halstead Blvd. Permit Number: SW7960108 Location: Pasquotank County Applicant: First Investment Associates of Elizabeth City, LLC Mailing Address: P.O. Box 7246 Rocky Mount, NC 27804 Application Date: January 22, 1996 Water Body Receiving Stormwater Runoff: Classification of Water Body: Pond Depth: Permanent Pool Elevation: Total Impervious Surfaces Allowed: Required Surface Area: Provided Surface Area: Knobbs Creek C 6 feet 6.0 MSL 1.58 acres 2870 square feet 2880 square feet 4 Required Storage Volume: Provided Storage Volume: Controlling Orifice: 6127 cubic feet 6134 cubic feet 1.125 inch pipe 4. No homeowner/lot owner/developer shall be allowed to fill in, alter, or pipe any vegetative practices ( such as swales ) shown on the approved plans as part of the stormwater management system without submitting a revision to the permit and receiving approval from the Division. 5. The following items will require a modification to the permit: a. Any revision to the approved plans, regardless of size b. Project name change C. Transfer of ownership d. Redesign or addition to the approved amount of built -upon area e. Further subdivision of the project area. In addition, the Director may determine the other revisions to the project should require a modification to the permit. 6. The Director may notify the permittee when the permitted site does not meet one or more of the minimum requirements of the permit. Within the time frame specified in the notice, the permittee shall submit a written time schedule to the Director for modifying the site to meet minimum requirements. The permittee shall provide copies of revised plans and certification in writing to the Director that the changes have been made. II. SCHEDULE OF COMPLIANCE 1. The permittee will comply with the following schedule for construction and maintenance of the stormwater management system. a. The stormwater management system shall be constructed in its entirety, vegetated and operational for its intended use prior to the construction of any built -upon surfaces except roads. b. During construction, erosion shall be kept to a minimum and any eroded areas of the system will be repaired immediately. 5 2. The facilities must be properly maintained and operated at all times. The approved Operation and Maintenance Plan must be followed in its entirety and maintenance must occur at the scheduled intervals. 3. The permittee shall at all times provide the operation and maintenance necessary to assure the permitted stormwater system functions at optimum efficiency including, but not limited to: a. Semiannual scheduled inspections (every 6 months) b. Sediment removal C. Mowing and revegetation of side slopes d. Immediate repair of eroded areas e. Maintenance of side slopes in accordance with approved plans and specifications f. Debris removal and unclogging of outlet structure, orifice device and catch basins and piping. 4. Records of maintenance activities must be kept and made available upon request to authorized personnel of DEM. The records will indicate the date, activity, name of person performing the work and what actions were taken. 5. This permit shall become voidable unless the facilities are constructed in accordance with the conditions of this permit, the approved plans and specifications, and other supporting data. 6. Upon completion of construction and prior to operation of this permitted facility, a certification must be received from an appropriate designed for the system installed certifying that the permitted facility has been installed in accordance with this permit, the approved plans and specifications, and other supporting documentation. Mail the Certification to the Washington Regional Office, 1424 Carolina Avenue, Washington, North Carolina, 27889, attention Water Quality Section. 7. A copy of the approved plans and specifications shall be maintained on file by the Permittee for a minimum of five years from the date of the completion of construction. III. GENERAL CONDITIONS 1. This permit is not transferable. In the event there is a desire for the facilities to change ownership, or there is a name change to the Permittee, a formal permit request must be submitted to the Division of Environmental Management accompanied by an application fee, documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request will be considered on its merits and may or may not be approved. R 2. Failure to abide by the conditions and limitations contained .in this permit may subject the Permittee to enforcement action by the Division of Environmental Management, in accordance with North Carolina General Statute 143-215.6(a) to 143-- 215.6(c). 3. The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction. 4. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement stormwater management systems. 5. The permit may be modified, revoked and reissued or terminated for cause. The filing of a request for a permit modification, revocation and reissuance or termination does not stay any permit condition. Permit issued this the 16th day of February, 1996. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION YA. Preston Howard, Jr., P.E., Director Division of Environmental Management By Authority of the Environmental Management commission Permit Number SW7960108 7 Hampton Inn Hotel - Halstead Blvd. Pasquotank County Stormwater Permit No. SW7960108 Designer's Certification , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (periodically/weekly/full time) the construction of the project, for (Project) (Project Owner) hereby state that to the best of 'my abilities, due care and diligence was used in the observation of the project construction such that the construction was observed to be built within substantial compliance and intent of the approved plans and specifications. Signat Registration Number Date 8 RECEIVE WASHNGTON OFFICE DIVISION OF ENVIRONMENTAL MANAGEMENT AN 2.2 1996 NORTH CAROLINA STORMWATER MANAGEMENT PERMIT APPLICATIOB M. x hi GENERAL INFORMATION: 1. Project Name: to n Hotel 2. Project Location: (County, State Road, Address) Pasquotank County, SR 1152 402 Halstead Boulevard, Elizabeth City, NC 27909 3. Owner's Name: First Investment Associates of Phone: (919)937-8111 Elizabeth City, LLC 4. Mailing Address: p.C."'Box 7246 City Rocky Mount State NC Zip 27804 5. Application Date: 1.2-13-95 Fee Submitted: $385. 00 7. Nearest Receiving Stream: Knobbs Creek Class: C Sw 8. Project Description: Five (5) story, 100 room hotel II. PERMIT INFORMATION 1. Permit No. (will be completed by DEM) 2. Permit Type: X New Renewal Modification (existing permit no.) 3. Project Type: Low Density X. Detention infiltration Other 4. Other State/Federal Permits/Approvals Required: (Check appropriate blanks) X Sediment/Erosion Control LAMA Major 404 Permit III. PROJECT BUILT UPON AREA Drainage Drainage Basin Basin Breakdown of Impervious Areas Classification C SW Buildings 0.30 AC Allowable Impervious 30% Roads Total Project Area 2.44 '� Parking 1. 28 AC Proposed Impervious 1.58 Other '� % Impervious Area 64. 80/ Totals 1.58 AC IV. STORMWATER TREATMENT (Describe how runoff will be treated): V. DEED RESTRICTIONS AND PROTECTIVE COVENANTS Deed restrictions and protective covenants are required for all low density projects and all subdivisions prior to the sale of any lot. Please see Attachment A for specific requirements. By your signature below, you certify that the recorded deed restrictions and protective covenants for this project shall include all the items required by the permit, that the covenants will be binding on all parties and persons claiming under them, that they will run with the land, that the covenant cannot be changed or deleted without concurrence from the state, and that they will be recorded prior to the sale of any lot. OWNER'S CERTIFICATION I_Richard Y. Tharringtor� _ _ certify that the (Please print name clearty) information included on this permit application form is correct, that the project will be constructed in conformance with the approved plans, that the deed restrictions will be recorded with all required permit conditions, and that to the best of my knowledge, the proposed pro) 'ect complies with the requirements of 15A NCAC 2H.1000. I ore th b named person or firm to submit stormwater plans on my behalf Owner/ uth ure and Title Date AUTHORIZED AGENT Person or Firm Name: Sean C: Robey,P.E. Robey Associates Engineering Mailing Address: P.O. Box 2705 city Elizabeth City Phone: (919)335-1888 state NC zip 2.7906 Please submit application, fee and plans to appropriate Regional Office. (see attached map) -2- i ATTACHMENT A LOW DENSITY PROJECTS GENERAL SUBMITTAL REQUIREMENTS 1. A completed coastal stormwater permit application. 2. Two sets of plans showing north arrow, scale, revision date, property/project boundaries clearly marked, contours, drainage basins, mean high water line, wetlands, easements, a minimum 30' buffer between surface waters and proposed impervious areas, and road cross -sections. 3. Calculations of the built -upon area. For subdivisions, please show the methodology for arriving at the per lot built -upon area. For non - subdivision projects, break down the calculation into buildings, roads, parking and other (include all impervious areas). 4. Low Density projects with curb and gutter will require: - drainage basins and swale locations delineated on plans - detail of swales (minimum 100 l.f. and 5:1 side slopes) - velocity calculations - inlet -outlet elevations - type of grass cover DEED RESTRICTION REQUIREMENTS NOTES: The following items must be included for all low density projects: No more than square feet of any lot, including that portion of the right-of-way between the edge of pavement and the front lot line, shall be covered by impervious structures, including asphalt, gravel, concrete, brick, stone, slate or similar material, not including wood decking or the water surface of swimming pools. This covenant is intended to ensure compliance with the stormwater permit issued by the State of North Carolina. The covenant may not be changed or deleted without the consent of the State. 1. if lot sizes vary significantly, owner should provide attachment with lot number, size and allowable impervious area for each lot. 2. No one may fill in or pipe any roadside swales or lot line swales, except as necessary to provide a driveway crossing. 3. For curb and gutter projects, no one may pipe, fill in or alter any lot line swale used to meet North Carolina stormwater Permit requirements. S ROBEY ASSOCIATES SEAN C. ROREY, P.E. Off ice (919) 335-1888 ENGINEERING F(a (919) 338-9888 CIVIL - SANITARY January 29 1996 REWASHINGTON OFFICE Mr. Bill Moore KjAN 3 0 M6 Dept. of Natural Resources and Community Development Water Quality Section IL L AL 1424 Carolina Avenue P.O. Box 1502 Washington, NC 27889 Subject: Sedimentation/Erosion Control Plan Hampton Inn Proj. 4 412 Dear Mr. Moore: Enclosed for your review is the Stormwater calculations for the referenced project, per your letter dated January 24. The operation and maintenance agreement will be forwarded from Mr. Tharrington. Sincerely, Sean C. Rob , cc: Mr. Richard Y. Tharrington file Mailing Address: P. O. Box 2705 Elizabeth City, NC 27906-2705 Office : 523 S. Hughes Blvd. Elizabeth Citv, NC 27909 1 State of North Carolina Department of Environment, Health and Natural Resources Washington Regional Office James B. Hunt, Jr., Governor Jonathan B. Howes, Secretary DIVISION OF ENVIRONMENTAL MANAGEMENT WATER QUALITY SECTION January 24, 1996 First Investment Associates of . Elizabeth City, LLC Attn: Mr. Richard Y. Tharrington PO Box 7246 Rocky Mount, NC 27804 Subject: Application No. SW7960108 Hampton Inn Hotel -Halstead Blvd Pasquotank County Dear Mr. Tharrington: The Washington Regional Office acknowledges receipt of your permit application and supporting information on January 22, 1996. This application has been assigned the number listed above. A preliminary review of your project has been completed. The following additional information is needed before a permit can be issued: - stormwater calculations including SA/DA ratios and orifice sizing - operation and maintenance agreement The above information must be submitted within 30 days, or your application will be returned as incomplete. If you have questions, please feel free to contact Bill Mocra at (919) 946- 6481, extension, 264. Sincerely, �oy Roger K. Tho e Water Quality Supervisor Washington Regional Office cc: bey & Associates Washington Regional Office 1424 Carolina Avenue, Washington, NC 27889 Telephone 9191946-6481 FAX 919/975-3716 An Equal Opportunity Affirmative Action Employer 50%recycled/10% post -consumer paper PERMANENT POOL DETENTION PONDS DESIGN OF POND Hampton Inn 10 Yr, 24 I-r Storm Robey Associates Engineering P. O. Box 2705 Elizabeth City, NC 27909 (919)-335-1888 12/05/95 Page I SAIDA PERCENTAGES FOR 85% TSS REMOVAL WITH 30' VEGETATIVE FILTER %. 1MPRV 3.0 FT 3.5 FT 4.0 FT 4.5 FT 5.0 FT 5.5 FT 6.0 FT 10% 0.9 0.8 0.7 0.6 0.5 20% 1.7 L3 1.2 1.1 1.0 0.9 0.8 30% 2.5 2.2 L9 1.8 1.6 1.5 1.3 40% 3.4 3.0 2.6 2.4 2.1 1.9 1.6 30% 4.2 3.7 3.3 3.0 2.7 2.4 2.1 60% 5.0 4.5 3.8 3.5 3.2 2.9 2.6 70% 6.0 5.2 4.5 4.1 3.7 3 A 2.9 80% 6.3 6.0 5.2 4.7 4.2 3.7 3.2 90% 7.5 6.5 5.8 5.3 4.8 4.3 3.8 100% 8.2 7.4 6.8 6.2 5.6 5.0 4.4 WATERSHED AREA: 2.44 ACRES WATERSHED % RviPERVIOUS: 64 % PERMANENT POOL ELEVATION: 6 FT DESIGN PERMANENT POOL DEPTH: 6 FT SA/DA PERCENTAGE FACTOR: 2.7 % POND SURFACE AREA REQ'D: 17ORESAY AREA. AT WIDTH = 0.5 LENGTH, WIDTH = 37.88 LF LENGTH = 75.759 LF 2870 SF 574 SF 6.5 FT 7.0 FT 7.5 FT 0.7 0.6 0.5 1.2 1.0 0.9 1.4 1.1 LO 1.8 1.5 1.3 2.3 2.0 L6 2.5 2.1 1.8 2.7 2.2 2.0 3.3 2.8 2.3 3.8 3.2 2.6 (FROM ABOVE TABLE -TAKEN FROM DESIGN OF STORM WATER CONTROL FACILMES WORKSHOP MANUAL- PENC 1998) (BASED UPON MINIMUM SURFACE AREA) Use these dimensions: WIDTH 24 LF 'y ti880 s LENGTH 120 LF VOLUME OF I" RAINFALL AREA OF ROOFS: 0.3 AC AREA OF PARKING/CONCRETE: 1.28 AC AREA OF GREEN AREAS: 0.86 AC VOLUME OF RUNOFF 6127.4 CF STORAGE DEPTH FOR MINIMUM AREA = ELEVATION OF V RAINFALL = 8.13 Normal Pool Elevation 6 VOL (CF)=[(ROOF" I.0)+(PARKING'.95)+(GRASS-0.2)1-43,560112 2.13 FT X 2,boa f' Z: 61 P- LF Py,-''�-kwo- DRAWDOWN - WATER QUALITY Q(2 DAYS) = 0.0355 CFS Q(5 DAYS) _ .0.0142 CFS I" RUNOFF STAGE 2.13 FT DEPTH OF DRAWDOWN DEVICE BELOW OUTLET 1.5 FT l" RUNOFF OUTLET DEVICE: 0.9573 INCH DIA HOLE DIAMETER OF HOLE TO USE: 1.125 INCH DiAWTER l " STORM RUNOFF DRAWDOWN TIME 2.0688 DAYS INFLOW HYDROGRAPH Return Year Storm 10 Yr Qp = Peak Discharge = 9.5 cfs To = Time fo Concentration = Calculation of Tp (Time to Peak) From SCS NEH 4, page 15-7 Eqn. 15.4 A=[Q/(Cd* SQRT(2 g1i)) I * 144 Rad.=SQRT(A/PI) Dia.=2*Rad. 10 min Lag Time (L) = (1^0.8*(S+1)^0.7)/(1900*Y^0.5) for Lin Hrs where: l = hydraulic'length of watershed (R) S = (IOOOICN)-10 CN = approximately same CN from TR-55 Y = avg. watershed land slope in % S = (1 OOO/CN)-10 = 0.8696 L= 0.1428 hrs From SCS NEH 4 , page 16-7 Eqn. 16.7 Tp=D/2+L where : D = unit of excess duration rainfall (hrs) L = Lag Time (hrs) From SCS NEH 4, page 16-8 Eqn. 16.12 D = 0.133 tc where: Tc = Time of Concentration (hrs) - (See Tr-55 Printout) I IEREFORE: D = 0.0222 hrs Tp = 0.1538 hrs = 9.2305 min Volume under Hydrograph = 1.39 * Qp * Tp = 7313.3 Cubic Feet 9 Page 2 300 11 0.8696 92 0.3 % Inflow Hydrograph SCS Dimensionless Hydrograph Time Discharge Time Discharge Volume Ratio Ratio hr efs cf 0.00 0.00 0.00 0.10 0.03 0.02 0.20 0.10 0.03 0.30 0.19 0.05 0.40 0.31 0.06 0.50 0.47 0.08 0.60 0.66 0.09 0.70 0.82 0,11 0.80 0.93 0.12 0.90 0.99 0.14 1.00 1.00 0.15 1.10 0.99 0.17 1.20 0.93 0.18 1.30 0.86 0.20 1.40 0.78 0.22 1.50 0.68 0.23 1.60 0.56 0.25 1.70 0.46 0.26 1.80 0.39 0.28 1.90 0.33 0.29 2.00 0.28 0.31 2.20 0.21 0.34 2.40 0.15 0.37 2.60 0.11 0.40 2.80 0.08 0.43 3.00 0.06 0.46 3.20 0.04 0.49 3.40 0.03 0.52 3.60 0.02 0.55 3.80 0.02 0.58 4.00 0.01 0.62 4.50 0.01 0.69 5.00 0.00 0.77 Volume under hydrograph = 0 0 16 1 53 2 100 3 163 4 247 6 347 8 431 9 489 9 521 10 526 9 521 9 489 8 452 7 410 6 358 5 295 4 242 4 205 3 174 3 147 2 218 l 155 1 113 1 81 1 58 0 42 0 31 0 22 0 16 0 12 0 13 0 0 6947 Cf Page 3 Based upon runoff volume = 7313.3 cf Depth req'd for minimum area = 2.5393 ft STAGE STORAGE FUNCTION OF POND Page 4 (FOR RECTANGULER DETENTION POND ONLY) Pond Side Slope (M) _ Minimum surface area taken at normal water level BASIN AREA INCR ACCUM VOLUME VOLUME STAGE In s In Z Z est Elevation S Z sr cf of a 2880 0 0 0 Surface area at normal pool 6 3321 1550 1550 0.5 7.35 -0.69 0.49 6.5 3780 1775 3326 l 8.11 0.00 0.95 7 4257 2009 5335 1.5 8.58 0.41 1.44 7.5 4752 2252 7587 2 8.93 0.69 1.95 8 5265 2504 10091 2.5 9.22 092 2.50 8.5 5796 2765 12857 3 9.46 1.10 3.08 9 6345 3035 15892 3.5 9.67 1.25 3.71 9.5 6912 3314 19206 4 9.86 1.39 4.37 10 7497 3602 22808 4.5 10.03 1.50 5.07 10.5 8100 3899 26708 5 10.19 1.61 5.82 11 Regression Output: Constant 9.3435 Ks = S/Z^b = 3511.2 SO Err of Y Est 0.0097 R Squared 0.9996 No. of Observations 7 Degrees of Freedom 5 X Coefficient(s) 1.1521 = b Std Err of Coe[. 0.0101 FOR VERTICAL SIDED DETENTION POND SET b=0, AND Ks = SURFACE AREA (SF) STAGE DISCHARGE (FOR RiSER/13ARRELL SPILLWAY W EMERGENCY WEIR) RISER Dr - 30 Riser Dia. (in) ' Etop = 9.20 Elev, Top Riser (ft) 8.54 Cwr - 3.33 Riser weir eoeff Cdr - 0.60 Riser orifice coetf HIn ., = 8 Number of Holes HId = 2 Hole Dia. (in) EH I = 8.13 Clev. Holes (1) H2n - 0 Number of Holes 142d - 2 Hole Dia. (in) EH2 = 15.00 Elev. Holes (2) H3n = 0 Number of Holes Had = 2 Hole Dia. (in) EH3 = 15.00 Elev. Holes (3) BARREL: Db = 18 Barrel Dia. (in) Einv = 6.00 Elev Invert Barrel (ft) Barrell Adjustment Factor Cdb = 0.60 Barrel orifice coeff 3 0 EMERGENCY WEIR Page 5 Cw = 3 Weir coeff Ecr - 15.00 Elev weir coe1T([I) Lw = 20 Weir Length (ft) Riser Riser Riser Elevation Hole Hole Hole Riser Riser Barrel Principal Emergcy Total (1) (2) (3) (weir) (orifice) Spillway Weir Outflow 6.00 0.0 0.0 0.0 0.0 0.0 0.0 0.00 0.0 0.00 6.00 0.0 0.0 0.0 0.0 0.0 0.0 0.00 0.0 0.00 6.01 0.0 0.0 0.0 0.0 0.0 0.0 0.00 0.0 0.00 6.03 0.0 0.0 0.0 0.0 0.0 0.0 0.00 0.0 0.00 6.07 0.0 0.0 0.0 0.0 0.0 0.1 0.00 0,0 0.00 6.13 0.0 0.0 0.0 0.0 0.0 0.2 0.00 0.0 0.00 6.21 0.0 0.0 0.0 0.0 0.0 0.4 0.00 0.0 0.00 6.31 0.0 0.0 0.0 0.0 0.0 0.7 0.00 0.0 0.00 6.44 0.0 0.0 0.0 0.0 0.0 12 0.00 0.0 0.00 6.57 0.0 0.0 0.0 0.0 0.0 L7 0.00 0.0 0.00 6.71 0.0 0.0 0.0 0.0 0.0 2.4 0.00 0.0 0.00 6.85 0.0 0.0 0.0 0.0 0.0 3.1 0.00 0.0 0.00 6.98 0.0 0.0 0.0 0.0 0.0 3.9 0.00 0.0 0.00 7.10 0.0 0.0 0.0 0.0 0.0 4.6 0.00 0.0 0.00 7.21 0.0 0.0 0.0 0.0 0.0 5.3 0.00 0.0 0.00 7.30 0.0 0.0 0.0 0.0 0.0 6.0 0.00 0.0 0.00 7.39 0.0 0.0 0.0 0.0 0.0 6.6 0.00 0.0 0.00 7.46 0.0 0.0 0.0 0.0 0.0 7.1 0.00 0.0 0.00 7.51 0.0 0.0 0.0 0.0 0.0 7.4 0.00 0.0 0.00 7.56 0.0 0.0 0.0 0.0 0.0 7.7 0.00 0.0 0.00 7.60 0.0 0.0 0.0 0.0 0.0 7.8 0.00 0.0 0.00 7.67 0.0 0.0 0.0 0.0 0.0 8.1 0.00 0.0 0.00 7.72 0.0 0.0 0.0 0.0 0.0 8.4 0.00 0.0 0.00 7.75 0.0 0.0 0.0 0.0 0.0 8.5 0.00 0.0 0.00 7.78 0.0 0.0 0.0 0.0 0.0 8.6 0.00 0.0 0.00 7.80 0.0 0.0 0.0 0.0 0.0 8.7 0.00 0.0 0.00 7.81 0.0 0.0 0.0 0.0 0.0 8.7 0.00 0.0 0.00 7.82 0.0 0.0 0.0 0.0 0.0 8.8 0.00 0.0 0.00 7.83 0.0 0.0 0.0 0.0 0.0 8.8 0.00 0.0 0.00 7.83 0.0 0.0 0.0 OM 0.0 8.8 0.00 0.0 0.00 7.84 0.0 0.0 0.0 0.0 0.0 8.9 0.00 0.0 0.00 7.84 0.0 0.0 0.0 0.0 0.0 8.9 0.00 0.0 0.00 7.85 0.0 0.0 0.0 0.0 0.0 8.9 0.00 0.0 0.00 Page 6 ROUTING OF INFLOW HYDROGRAPH THROUGH POND AND OUTFLOW DEVICE Total Riser Riser Riser Barrel Emerg Time Inflow Storage Stage Outflow Holes (weir) (orifice) Spillway t (hr) efs cf Elevation cfs (1+2+3) cfs cfs cfs cfs cfs 0.000 0 0 6.00 0.00 0.00 0.00 0.00 0,00 0.00 0.015 0 0 6.00 0.00 0.00 0.00 0.00 0.00 0.00 0A31 1 15.784 6.01 0.00 0.00 0.00 0.00 0,00 0.00 0.046 2 68.398 6.03 0.00 0.00 0.00 0.00 0.02 0.00 0,062 3 168.36 6.07 0.00 0.00 0.00 0.00 0.08 0.00 0.077 4 331.47 6,13 0.00 0.00 0.00 0.00 0.19 0.00 0.092 6 578.75 621 0.00 0.00 0.00 0.00 0,38 0.00 0.108 8 926 6.31 0.00 0.00 0.00 0.00 0,71 0.00 0.123 9 1357.4 6.44 0.00 0.00 0.00 0.00 1.17 0.00 0.138 9 1846.7 6.57 0.00 0.00 0.00 0.00 1.74 0M 0.154 10 2367.6 6.71 0.00 0.00 0.00 0.00 2,41 0.00 0.169 9 2893.8 6.85 0.00 0.00 0.00 0.00 3,12 0.00 0.185 9 3414.6 6.98 0.00 0.00 0.00 0,00 3.87 0.00 0.200 8 3903.9 7.10 0.00 0.00 0.00 0.00 4.6E 0.00 0.215 7 4356.4 721 0.00 0.00 0.00 0.00 5.32 0.00 0231 6 4766.8 7,30 0.00 0.00 0.00' 0.00 5.98 0.00 0.246 5 5124.6 7.39 0.00 0.00 0.00 0.00 6.57 0.00 0.262 4 5419.2 7.46 0.00 0.00 0.00 0,00 7.07 0.00 0.277 4 5661.2 7,51 0.00 0.00 0.00 0.00 7.42 0.00 0.292 3 5866.4 7,56 0.00 0.00 0.00 0.00 7.65 0.00 0.308 3 6040.1 7.60 0.00 0.00 0.00 0.00 7.84 0.00 0.338 2 6334.7 7.67 0.00 0.00 0.00 0,00 8.14 0.00 0,369 1 6552.5 7.72 0.00 0,00 0.00 0.00 8.36 0.00 0.400 1 6707.2 7.75 0.00 0.00 0.00 0.00 8.51 0.00 0.431 1 6819.8 7,78 0,00 0.00 0.00 0.00 8,62' 0.00 0.462 1 6900.8 7.80 0.00 0.00 0.00 0.00 8.70 0.00 0,492 0 6958.7 7,81 0.00 0,00 0.00 0.00 8.75 0.00 0.523 0 7000.8 7.82 0.00 0.00 0.00 0.00 8.79 0.00 0.554 0 7031.3 7.83 0.00 0.00 0.00 0.00 8.82 0.00 0.585 0 7053.4 7.83 0,00 0.00 0.00 0.00 8,84 0.00 0.615 0 7069.2 7.84 0.00 0.00 0.00 0.00 8.85 0.00 0,692 0 7098.1 7.84 0.00 0.00 0.00 0.00 8.88 0.00 0.769 0 7111.3 7.85 0.00 0.00 0.00 0.00 8,89 0.00 7.8451 = maximum stage elevation 0 = maximum discharge 10 9 8 7 6 y an 5 q 3 2 1 0 Hampton Inn - Elizabeth City, NC 10 yr STORM 0 0.1 0.2 0.3 0A 0.5 0.6 0.7 0.8 Time (hrs) INFLOW (cfs) — OUTFLOW (cfs) 0.9 State of North Carolina Department of Environment, Health and Natural Resources Washington Regional Office James B. Hunt, Jr., Governor Jonathan B. Howes, Secretary DIVISION OF ENVIRONMENTAL MANAGEMENT WATER QUALITY SECTION January 24, 1996 First Investment Associates of Elizabeth City, LLC Attn: Mr. Richard Y. Tharrington PO Box 7246 Rocky Mount, NC 27804 Subject: Application No. SW7960108 Hampton Inn Hotel -Halstead Blvd Pasquotank County Dear Mr. Tharrington: . The Washington Regional Office acknowledges receipt of your permit application and supporting information on January 22, 1996. This application has been assigned the number listed above. A preliminary review of your project has been completed. The following additional information is needed before a permit can be issued: stormwater calculations including SA/DA ratios and orifice sizing operation and maintenance agreement The above information must be submitted within 30 days, or your application will be returned as incomplete. If you have questions, please feel free to contact Bill Moore at (919) 946- 6481, extension, 264. �bySincerely, Roger Kho/e Water Quality Supervisor Washington Regional Office cc: Robey & Associates Washington Regional Office 1424 Carolina Avenue, Washington, NC 27889 Telephone 919/946-6491 FAX 919/975-3716 An Equal Opportunity Affirmative Action Employer 50%recycled/10% post -consumer paper ROBEY ASSOCIATES SEAN C. ROBEY, P.E. ENGINEERING Office (919) 33-1888 _ Fax (9I9) 338-9888 CIVIL - SANITARY December 21, 1995 a1W f-•e- �o 0 Mr. Bill Moore t'o S, 1PIp cis, Dept. of Natural Resources and Community Development Water Quality Section 1424 Carolina Avenue ✓ S� ��� P.O. Box 1502 Washington, NC 27889 Subject: Sedimentation/Erosion Control Plan WASHINGTON OFFICE Hampton Inn Proj. # 412 JAN 2. 2 995 Ill+ Z IL Dear Mr. Moore: Enclosed for your review and approval, please find the following items: 1. Two (2) copy of the "Streets, Grading and Sediment & Erosion Control Plan", Sheets 2,3,5 & G of G. 2. One (1) copy of the Stormwater Exemption Application. 3. Check in the amount of $385.00 for the required fee. Please note a sedimentation and erosion control plan has been submitted as of this date. f you have any questions, please do not hesitate to call. 5ince ly, Se C. RoV.yP.E. cc: Mr. Richard Y. Tharrington file enclosure(s) Mailihhg Address: P. O. Box 2705 Elizabeth City, NC 27906-2705 Office: 523 S. Hughes Bit,(]. Elizabeth City, NC 27909 M ANAG E M E N I. I N C. January 30, 1996 A WA5N1NGE OFFICE IAN 3 1 tom$ a 1- r. Mr. Bill Moore DEHNR - Water Quality Section 1424 Carolina Avenue Washington; NC 27889 RE: HAMPTON INN-ELIZABETH CITY, NC APPLICATION #SW7960108 Dear Mr. Moore: At the direction of Robey Associates Engineering, enclosed please find the executed DETENTION POND MAINTENANCE AGREEMENT on behalf of the subject property. Should you have comments or questions, please do not hesitate to give me a call. Sincerely, IRS�CQ INS MANAGEMENT, INC. President CLW Enclosure cc: Sean Robey P.O. Box 7246 9 Rocky Mount, North Carolina 27804 • (919) 937-8111 9 Fax (919) 937-81 12 HAMPTON INN-ELIZABETH CITY, NC DETENTION POND MAINTENANCE AGREEMENT RECEIVED MASNINGTON pFFICE ,1AN 3 1 996 & F_ M. 1. Operation and maintenance of the detention pond shall be the responsibility of the Owner:--__ . 2. Operation of the system is automatic upon the occurrence of a rainfall event, however, there are several maintenance items that must be attended to. First of all, there must be a lawn maintenance program where the grass around the pond will be kept mowed during the growing season of the year. It is recommended for aesthetic reasons that the grass be mowed on at least a bi-weekly basis unless actual growing conditions indicate otherwise, in which case the mowing frequency should be modified to suit site conditions. 3. The outlet structure must be inspected periodically for obstructions and trash build-up. This inspection should be done approximately once every three months to include inspection of the orifice in the drawdown device to check for algae or other trash plugging the orifice, inspection of the rip -rap filter around the riser section for trash, cut weeds or grasses which may tend to plug the filter, inspection of the trash rack for the same type of obstructions as with the rip -rap filter and an inspection of the barrel section for any obstructions such as limbs or anything else that may have passed the trash rack and pose a plugging problem. Any obstructions found shall be removed and hauled away from the pond. 4. The forebay area must be checked for sediment deposits, especially during the first year of operation. The frequency of the forebay inspections should be monthly until all disturbed areas have been stabilized or for a minimum of 6 months, whichever is longer. Thereafter, inspect forebay area every three months. To perform this inspection, elevations should be taken along the perimeter of the rip -rap flow distribution/velocity dissipation pad. The bottom should be approximately 2' to 2 1/2' below the permanent pool elevation. If this is not the case, the rip -rap pad will need to be removed, the sediments excavated to the levels indicated in the details, and the rip -rap pads replaced. S. It should be noted that in addition to the inspection frequencies recommended above, the pond and its appurtenances should be inspected after any major storm event that may transport large amounts of debris to the pond. By our signature below, First Investment Associates of Elizabeth City, LLC, as Owner of the proposed facility do hereby agree to perform the above mentioned items and maintain the proposed facility in proper operating condition. INVE MENT ASSOCIATES OF BETH_AakY, L14 I'l