HomeMy WebLinkAbout20201102 Ver 1_USACE Permit_20201009U.S. ARMY CORPS OF ENGINEERS WILMINGTON DISTRICT Action Id. SAW-2019-01884 County: Guilford U.S.G.S. Quad: NC-McLeansville GENERAL PERNHT (REGIONAL AND NATIONWIDE) VERIFICATION Permittee: City Switch II -A, LLC Attn: Jason Groseclose Address: 1900 Century Place, Suite 320 Atlanta, GA 30345 Size (acres) —7.46 Nearest Town McLeansville Nearest Waterway UT to North Buffalo Creek River Basin Cape Fear USGS HUC 03030002 Coordinates 36.1149,-79.7088 Location description: The project area is located on the south side of Camp Burton Road, approximately 0.25 mile east of its intersection with Rankin Mill Road, at 4226 Camp Burton Road, in McLeansville, Guilford County, North Carolina. Description of projects area and activity: This verification authorizes the permanent discharge of fill material into 46 linear feet (0.005 acre) of stream channel (all a loss of waters of the US ) and 0.04 acre of riparian non-riverine wetlands, necessary for the installation of one road crossing for construction access and long-term maintenance of a cellular tower. Applicable Law(s): © Section 404 (Clean Water Act, 33 USC 1344) ❑ Section 10 (Rivers and Harbors Act, 33 USC 403) Authorization: NWP 39. Commercial and Institutional Developments REMARKS: The use of this permit has been verified After -the -Fact. SEE ATTACHED NWP GENERAL, REGIONAL, AND/OR SPECIAL CONDITIONS Your work is authorized by the above referenced permit provided it is accomplished in strict accordance with the enclosed Conditions, your application signed and dated 8/27/2020, and revised information sent via email on 10/9/2020, and the enclosed plans Sheet Numbers C-1, C-2.1, and C-9.3. Any violation of the attached conditions or deviation from your submitted plans may subject the permittee to a stop work order, a restoration order, a Class I administrative penalty, and/or appropriate legal action. This verification will remain valid until the expiration date identified below unless the nationwide authorization is modified, suspended or revoked. If, prior to the expiration date identified below, the nationwide permit authorization is reissued and/or modified, this verification will remain valid until the expiration date identified below, provided it complies with all requirements of the modified nationwide permit. If the nationwide permit authorization expires or is suspended, revoked, or is modified, such that the activity would no longer comply with the terms and conditions of the nationwide permit, activities which have commenced (i.e., are under construction) or are under contract to commence in reliance upon the nationwide permit, will remain authorized provided the activity is completed within twelve months of the date of the nationwide permit's expiration, modification or revocation, unless discretionary authority has been exercised on a case -by -case basis to modify, suspend or revoke the authorization. Activities subject to Section 404 (as indicated above) may also require an individual Section 401 Water Quality Certification. You should contact the NC Division of Water Resources (telephone 919-807-6300) to determine Section 401 requirements. For activities occurring within the twenty coastal counties subject to regulation under the Coastal Area Management Act (CAMA), prior to beginning work you must contact the N.C. Division of Coastal Management. This Department of the Army verification does not relieve the permittee of the responsibility to obtain any other required Federal, State or local approvals/permits. If there are any questions regarding this verification, any of the conditions of the Permit, or the Corps of Engineers regulatory program, please contact David E. Bailey at (919) 554-4884 X 30 or David.E.Bailev2(&usace.armv.mil. Corps Regulatory Official: Expiration Date of Verification: 03/18/2022 % Date: 2020.10.0915:10:19 -04'00' Date: 10/09/2020 The Wilmington District is committed to providing the highest level of support to the public. To help us ensure we continue to do so, please complete the Customer Satisfaction Survey located at http://corpsmapu.usace.army.mil/cm apex/f?p=136:4:0. Copy furnished: Nick Creidler, Headwater Environmental, Inc., 1121 Military Cutoff Road, Suite C #306, Wilmington, NC 28405 Sue Homewood, NCDEQ-DWR, 450 W. Hanes Mill Rd, Suite 300, Winston-Salem, NC 27105 I DRAINAGE NARRATIVE: THE PROPOSED SITE DISTURBANCE FOR THIS CELL TOWER SITE INCLUDES A 808' ONSITE ACCESS ROAD AND TURNAROUND, A 80'X80' NON -VEHICULAR GRAVEL COMPOUND, AND THE LANDSCAPE AREA SURROUNDING THE 80' X 80' GRAVEL COMPOUND. THE TOTAL PROPOSED DISTURBED AREA IS 40,487.52 SF (0.929 AC). THE TOTAL PROPOSED DISTURBANCE AREA IS LESS THAN 1 ACRE. A GRADING PERMIT IS NOT REQUIRED. THIS AREA IS CURRENTLY UNDEVELOPED. THE PRE -DEVELOPMENT FLOW RATE IS BASED ON THE RATIONAL METHOD (Q=CiA), C=0.35, i=0.304 IN/HR, A=7.47 AC FOR A 1DO-YR 24-HR DESIGN STORM PER NOAA ATLAS 14 POINT PRECIPITATION DATA. THE POST -DEVELOPMENT FLOW RATE IS CALCULATED USING THE RATIONAL METHOD WITH A WEIGHTED 'C' VALUE OF 0.38. THE PRE -DEVELOPMENT IMPERVIOUS COVER HAS BEEN TREATED AS 0 SF AND THE POST DEVELOPMENT IMPERVIOUS COVER IS 16,455.34 SF. THE PARENT PARCEL IS 325,257.31 SF. THE PROPOSED POST DEVELOPMENT IMPERVIOUS COVER IS 5.1% Qpre = 0.795 CPS Qpost = 0.863 CFS THE PROPOSED DEVELOPMENT WILL RESULT IN AN INCREASE IN STORMWATER RUNOFF OF 0.068 CFS. WATERSHED INFORMATION: NORTH BUFFALO CREEK THE NORTH BUFFALO CREEK SUBWATERSHED (HUC12: 030300020105) IS IN THE REEDY FORK WATERSHED (HUC10:0303000201) WITHIN THE HAW RIVER SUB BASIN (HUC8: 030300002) WHICH IS A PART OF THE CAPE FEAR RIVER BASIN (HUC6: 030300). NOTE: EXISTING ACCESS DRIVE SHALL CONSIST OF AN "ALL- WEATHER" GRAVEL SURFACE. PROPOSED 80' x 80' FENCED GRAVEL COMPOUND PROPOSED 100' x 100' LEASE PARCEL PROPOSED PARKING AND TURNAROUND AREA N/F CHARLOTTE FOGLEMAN PARCEL ID: 115371 ZONED - AG -AGRICULTURAL DB R 6723 PG 30 WETLAND LIMITS EXISTING 12" RCP c4mp (4SPN6IJRTON Ro 60,�W�AD —EXISTING RCP EXISTING OVERHEAD POWER N/F 61D W&SITIRLEY TATUM PARCEL ID: 115373 NED: AG -AGRICULTURAL N/A PROPOSED 12' WIDE / GRAVEL ACCESS ROAD PROPOSED 20' WIDE ACCESS & UTILITY EASEMENT PARENT PARCEL N/F LAWRENCE B. MAY PARCEL OF 115372 ZONED: AG -AGRICULTURAL DB 2602 PG 384 jk&Sk FAND LIMITS EXIST. STREAM SQ FT LEASE AREA PROPOSED 220' SELF SUPPORT TOWER OOVERALL r0000000ioiaii000i000ioii I .I 11 51 200 N/F SHERRY E. CASEY PARCEL ID: 115356 ZONED: RS-30 DB 4907 PG 1711 N/F THE CITY OF GREENSBORO PARCEL IF. 217968 ZONED: PI -UNKNOWN DB R 8059 PG 2437 WETLAND TABLE: STREAM LENGTH = 390' (PERENNIAL, WITHIN PARCEL) STREAM WIDTH = 3' +/- LENGTH OF STREAM IMPACTS 40' (CULVERT) IUATCC. 1. SEE LEGEND, SITE DATA, AND GENERAL NOTES ON SHEETS GN-1. 2. TOWER LATITUDE, LONGITUDE & ELEVATION MEET FAN-1-A" ACCURACY REQUIREMENTS. 3. PROPOSED SELF-SUPPORT TOWER. CENTER OF TOWER LATITUDE: NORTH 36o06'50.39" (36.113997) NAD 83 LONGITUDE: WEST-79o42'32.86" (-79.709128) NAD 83 GROUND ELEVATION @ 747T A.M.S.L. 4. THE PERPENDICULAR DISTANCES FROM THE CENTER OF PROPOSED TOWER TO PARENT TRACT BOUNDARY LINE WERE ESTABLISHED FROM ACTUAL FIELD MEASUREMENTS AND OBSERVATIONS PERFORMED BY POINT TO POINT LAND SURVEYORS 2/182019. AND ARE AS FOLLOWS: NORTH: 804.3't SOUTH: 228.6't EAST: 197.4't WEST: 111.8't 5. EXISTING FEATURES SHOWN ARE BASED ON FIELD SURVEY BY POINT TO POINT LAND SURVEYORS PERFORMED ON 2/182019. 6. THIS PLAN IS NOT A BOUNDARY SURVEY. PROPERTY BOUNDARY INFORMATION SHOWN IS FOR REFERENCE ONLY. POINT TO POINT LAND SURVEYORS DID NOT VERIFY BOUNDARY AS PART OF THIS SURVEY. DEED BEARING AND DISTANCE IN PARENTHESIS. 7. NO WETLANDS INVESTIGATION WAS PERFORMED AS PART OF THIS SURVEY. S. NO INVESTIGATION OF THE PRESENCE OF HAZARDOUS MATERIALS WAS PERFORMED AS A PART OF THIS SURVEY. f B+T C ITY SVWITC P& paouwAK low 0 W W a o 0 zN F o 7 00 0 U z� 5° �r w U ED N ] q C7 0 q N O N c�. a 1�1PROJECT NO: 132151 11CH CK BY: DLS ISSUED FOR: 9. UTILITIES SHOWN PER FIELD LOCATIONS FROM ABOVE REV I M. oawR 3-11 PnoR GROUND INSPECTION OF THE SITE AND UTILITY MARK -OUTS IN . of /oz1. ors R THE FIELD. UTILITIES THAT EXIST MAY NOT BE SHOWN.1 a 06/04/zo 1pus FlNPL fi OJ/OB/10 AU5 FlNPL 10. CONTRACTOR TO VERIFY POWER & TELCO DEMARCS WITH UTILITY PROVIDERS PRIOR TO BIDDING PROJECT. B&T ENGINEERING, INC. C-4171 Expires 6/30/20 11. NO WATER, WASTEWATER, OR SEPTIC UTILITIES ARE REQUIRED FOR THIS DEVELOPMENT. THIS DOCUMENT IS PRELIMINARY IN NATURE AND IS NOT A FINAL, SIGNED AND SEALED FLOOD ZONE NOTE: NO PORTION OF THIS PROPERTY IS LOCATED IN A SPECIAL FLOOD AREA AS PER F.I.R.M. COMMUNITY PANEL NO. 37107896003 DATED 6/18/2007. OVERALL SITE PLAN SHEET NUMBER: C-1 E \ _—t A (8o1ToM RIGI{r) PROPOSED 197 LFt PROPOSED 20' WIDE 12' WIDE GRAVEL / \ ACCESS &UTILITY ACCESS ROAD EASEMENT v \ PROP. UNDERGROUND \ \\EC. Conservative sca \ \ \ \ \ PROP. UNDERGROUND measurement of wetland impact TELCO , \ \ \ QQ Q \ \ PROPOSED AT&T 240 �� \ 3�SQ. FT. LEASE AREA NOTES: ACCESS DRIVE SHALL CONSIST OF AN "ALL- WEATHER" GRAVEL SURFACE. FG=744.7 _ \ \ �� REFER TO SHEET E-2 FOR CARRIER \ GROUND EQUIPMENT INFORMATION. WETLAND LIMITS FG=747.1 \ \\ \ \ \ \ \� U� FG=747.6 — FG=745.7 FG=747.1 _ G \ \ \ \ FG=747.2 TO \\ \ FG=742.4 12' DOUBLE— TOC=747.48 \ \ \ o SWING GATE \ \ =G=7477 \ \ \ PROPOSED SILT z FENCE (TYP) c-e FG=747 WE \ OV\ \\ TOTAL 230 LFt \ 92 \ FG=749.0 \ \mom \ \ =G=748.4 \ E \ 2 \\ \ GRAVEL c� FG=748.6 FG 749\ \ \ COMPOUND \9P \ 1 PROPOSED V V A V �V V THE A — — — P-a H-FRAME \ \ \ \ \ �Q \ SITE BEFORECONTRACTOR SHL MSIT THE B DDINGAON THE WORK \ \ \ \ \ \ F ST \ CONTAINED WTHIN THIS DESIGN i PROPOSED 220' SELF \ 2 c� SUPPORT TOWER \ \ \ 1 \ PACKAGE. DISCREPANCIES AND \ \ \\ \ \ \ \ FG=745.7 .aF\ \ OMISSIONS SHALL BE BROUGHT TO PROPOSED 50' x 50' \ \ \ \ TO BIDDING. THE ENGINEER'S ATTENTION PRIOR \ \ \ -�o FE \ED CO\POUN\ �\ \ \ \ \\ \\ \ 'ss PROPOSED 100' x 100' \ \ \ n LEGEND LEASE AREA \ \ \ s `r \ � \ \ \ \ e 745 INDICATES EXISTING CONTOUR ss o� FG=745.9 INDICATES FINISHED GRADE ELEVATION A PROPOSED IMPROVEMENTS PLAN/Illllli\ y-,,,,,,,,,,, 80 PROPOSED c9 WIDE GRN ROAD FG=725.9 FG=725.5 REMOVE 26' IXISTING 12" RCP �26 FG=725.8 TLAND LIMITS 14� 5 733 �731 �. PROPOSED 20' WIDE ACCESS & UTILITY EASEMENT UNDERGROUND 3TALL TEMPORARY INSTALL 40 L.F. 18" ADS N-12 S.D. PIPE WITH / END SECTIONS (OR APPROVED EQUAL) (SEE DETAILS 1, 2 SHEET C-9.3) FG=726.3 WETLAND LIMITS 'IATGH (Tppt EA © - /Illllll�i �'/oOooOOOO 40' 60OOoo000OOO. , 0 :, 11 735 LTY-SWITC 11itA1M, L'�4 a �]]] a o 0 X0 N F GG FFFiii � O � � o �-1 Uc Z � 5 0 w U �q N a PBOI F.CT VO: 132151 CH CK BY: DLS ISSUED FOR: B&ExpireC fi/30/20NC. THIS DOCUMENT IS PRELIMINARY IN NATURE AND IS NOT A FINAL, SIGNED AND SEALED PROPOSED IMPROVEMENTS PLAN SHEET NUMBER: C-2.1 20' ACCESS/UTILITIES EASEMENT PROPOSED TOP OF DRIVEWAY (MAINTAIN 1' MIN COVER OVER TOP OF PIPE) 12' 727 ---------------------------------- ---------------- EXISTING DRIVEWAY SURFACE- 726-------------------------------- FC=725.7- -----5_2�-�---- 725 T.O.P.=724.50 -\ I \ 724 723 722------------------------IE=722.80 _ PROPOSED 18" ADS N-12 HOPE PIPE W/ END SECTIONS OR APPROVED EOUAL, 20% 721 ---- STREAMBED BURIAL -- -1---------------------------------- FG=726.2 --- --------------------- T.O.P-=724.61 ________4EIT11NG ___ ___________________________________. EXISTINGGROUND--- - - ----------------- SURFACE-.91.___ _PIPE END SECTION () _________ISTING 12" RCP STORM DRAIN, W/ INVERT PERCHED APPROX 2° ABOVE FLOW LINE STORM DRAIN PROFILE SC­AL.T F B+T CITYSWtT C P& 19141lEi{'Al�, �:4 a o 0 zN F a z 0 0 V�775 ° N F w U i-1 N ] q C7 o 7 PROJECT VD: 132151 CHECKED BY: DLS ISSUED FOR: II B&T ENGINEERING, INC. GIIIIII THIS DOCUMENT IS PRELIMINARY IN NATURE AND IS NOT A FINAL, SIGNED ANJD CFAl.FD ENGINEERING DETAILS SHEET NUMBER: C-9.3 Action ID Number: SAW-2019-01884 Permittee: City Switch II -A, LLC (Attn: Jason Groseclose) County: Guilford Project Name: May site / cellular tower / 4226 Camp Burton Road / McLeansville / Guilford County / Commereial Date Verification Issued: 10/09/2020 Project Manager: David E. Bailey Upon completion of the activity authorized by this permit and any mitigation required by the permit, sign this certification and return it to the following address: US ARMY CORPS OF ENGINEERS WILMINGTON DISTRICT Attn: David E. Bailey Raleigh Regulatory Office U.S Army Corps of Engineers 3331 Heritage Trade Drive, Suite 105 Wake Forest, North Carolina 27587 or David.E.Bailey2@usace.army.mil Please note that your permitted activity is subject to a compliance inspection by a U. S. Army Corps of Engineers representative. Failure to comply with any terms or conditions of this authorization may result in the Corps suspending, modifying or revoking the authorization and/or issuing a Class I administrative penalty, or initiating other appropriate legal action. I hereby certify that the work authorized by the above referenced permit has been completed in accordance with the terms and condition of the said permit, and required mitigation was completed in accordance with the permit conditions. Signature of Permittee Date