Loading...
HomeMy WebLinkAboutNC0045993_Compliance Evaluation Inspection_20201008 (2)ROY COOPER Coverwr MICHAEL S. REGAN secretary S. DANIEL SMITH Director Mr. Preston M. Baucom, EHS ATI Allvac Monroe Plant Post Office Box 5030 Monroe, NC 281115030 NORTH CAROLINA En viraninen tat Quality October 08, 2020 SUBJECT: Compliance Evaluation Inspection ATI Allvac Monroe Plant WWTP NPDES Permit NCO045993 Union County, NC Dear Mr. Baucom: On October 6, 2020, Roberto Scheller of this Office conducted a compliance inspection at the subject facility. This inspection was conducted as a Compliance Evaluation Inspection (CEI) to insure compliance with permit requirements and conditions. The subject facility appeared to be well operated and we wish to thank the operating staff for assistance regarding this inspection. The enclosed report should be self-explanatory; however, should you have any questions, please do not hesitate to contact myself or Roberto Scheller at (704)235-2204 or roberto.scheller(a�ncdenr.gov. Sincerely, DocuSigned by: A14CC681AF27425... W. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Division of Water Resources, NCDEQ Enclosure: CEI Report No rth Caroiina Department of E nvuon menu! Quairty I Dimsoo of Water Resources Mooresville Regbfm! Office 1610 Es3 Center Avenue, Suite 301 I Mooresvlie, North Garoiina 25115 �L f •'� 704-ef3-1699 United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 1 2 u 3 I NC0045993 111 121 20/10/07 I17 18 LC] I 19 I s I 20L] 21111I I I I I I I II I I I I I I I I I I I I I I I I I I I I I I I II I I I I I r6 Inspection Work Days Facility Self -Monitoring Evaluation Rating 131 QA ---------------------- Reserved ------------------- 67 I 72 I ni I 71 I 74 79 I I I I I I I80 701� I 711 L LJ L -1 I I Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES Dermit Number) 10:OOAM 20/10/07 14/06/01 ATI Specialty Materials - Monroe Plant 2020 Ashcraft Ave Exit Time/Date Permit Expiration Date Monroe NC 28110 11:31AM 20/10/07 19/01/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Tommy W Long/ORC/704-289-4511/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Danny Caudle,2020 Ashcraft Ave Monroe NC 28110//704-289-4511/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit 0 Flow Measurement Records/Reports Self -Monitoring Progran Facility Site Review 0 Effluent/Receiving Wate Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date DocuSigned by: Roberto Scheller sC,4,u,,4- DWR/MRO WQ/252-946-6481/ 10/8/2020 E91C2A007838943E.- Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date W. Corey Basinger DWR/Division of Water Quality/704-235-2194/ EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. DocuSigned by: eyj � 10/8/2020 AlaccsalAFz7azs... Page# NPDES yr/mo/day Inspection Type NCO045993 I11 12I 20/10/07 117 18 i c i (Cont.) Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) At time of inspection records were current and available for review. Treatment facility appeared to be well maintained. Effluent was clear with no visible suspended solids. It was noted during inspection that water flowing through V-notch weir (Nappe) was collapsing against downstream face of weir plate. It is recommended that weir plate be checked for vertical level and slime growth cleaned from face of weir plate (downstream side). Flow over V-notch should be monitored to see if nappe continues to collapse against weir plate. Page# Permit: NCO045993 Owner -Facility: Inspection Date: 10/07/2020 Inspection Type: ATI Specialty Materials -Monroe Plant Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new 0 ❑ ❑ ❑ application? Is the facility as described in the permit? 0 ❑ ❑ ❑ # Are there any special conditions for the permit? 0 ❑ ❑ ❑ Is access to the plant site restricted to the general public? 0 ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? E ❑ ❑ ❑ Comment: Facility operating under permit that expired on January 31, 2019. Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? 0 ❑ ❑ ❑ Is all required information readily available, complete and current? 0 ❑ ❑ ❑ Are all records maintained for 3 years (lab. reg. required 5 years)? 0 ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? 0 ❑ ❑ ❑ Is the chain -of -custody complete? 0 ❑ ❑ ❑ Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCs Are DMRs complete: do they include all permit parameters? ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? ❑ ❑ ❑ (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operatc ❑ ❑ 0 ❑ on each shift? Is the ORC visitation log available and current? ❑ ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification? ❑ ❑ ❑ Is the backup operator certified at one grade less or greater than the facility classification' ❑ ❑ ❑ Is a copy of the current NPDES permit available on site? 0 ❑ ❑ ❑ Facility has copy of previous year's Annual Report on file for review? ❑ ❑ ❑ Comment: Flow Measurement - Effluent Yes No NA NE # Is flow meter used for reporting? 0 ❑ ❑ ❑ Is flow meter calibrated annually? E ❑ ❑ ❑ Page# 3 Permit: NC0045993 Inspection Date: 10/07/2020 Flow Measurement - Effluent Is the flow meter operational? Owner -Facility: ATI Specialty Materials -Monroe Plant Inspection Type: Compliance Evaluation (If units are separated) Does the chart recorder match the flow meter? Comment: Effluent Pipe Is right of way to the outfall properly maintained? Are the receiving water free of foam other than trace amounts and other debris? If effluent (diffuser pipes are required) are they operating properly? Comment: At time of inspection effluent was clear with no visible suspended solids. Yes No NA NE ■ ❑ ❑ ❑ ❑ ❑ ❑ Yes No NA NE ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Page# 4