Loading...
HomeMy WebLinkAboutNCG030617_DMR_20200304Stormwater Discharge Monitoring Report for North Carolina Division of Energy, Mineral and Land Resources General Permit No. NCG030000 Date submitted March 4, 2020 CERTIFICATE OF COVERAGE NO. NCG03 0 6 1 7 SAMPLE COLLECTION YEAR 2020 FACILITY NAME COMETECH, Inc. SAMPLE PERIOD 0 Jan -June ❑ July -Dec COUNTY Mecklenburg County or Q Monthly' (month) PERSON COLLECTING SAMPLES Michael Kilpatrick / Shealy Environmental DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ��c ❑Zero -flow [:]watersupply ❑SA D LABORATORY Shealy Environmental Services, Inc. Lab Cert. # 329 G.I.J ❑ Comments on sample collection or analysis: CE Other Class C Waterbody MAR 10 zub PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 CENTRAL FILES Part A: Stormwater Benchmarks and Monitoring Results pWR SECTiOFl ❑ No discharge this period?' Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Total Copper Total Lead Total Zinc Non -Polar 0&G/Total Total Petroleum Hydrocarbons Toxic Organics5 Benchmarks _ - 100 mg/L or 50 mg/O 6.0 — 9.0 0.010 mg/L 0.075 mg/L 0.126 mg/L 15 mg/L 1 mg/L Parameter Code - 46529 C0530 00400 01119 01051 01094 00552 78141 SWO-001 02/20/2020 0.2 36 7.2 0.053 <0.01 0,085 <5.0 Not Applicable SWO-002 02/20/2020 0.2 No Flow No Flow No Flow No Flow No Flow No Flow Not Applicable SWO-003 02/20/2020 0.2 8.2 7.3 <0.01 <0.01 <0.020 <5.0 Not Applicable ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 'The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Section B, Table 1 to identify the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2018-05/31/2021 SWU-245, last revised 11/1/2018 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Mike Mattes Name (Print name) CEO Title (Print title) �W _7 . Signature Date Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX me/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. n No discharge this period?' Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches' New Motor Oil or Hydraulic Oil Usage Non -Polar O&G/ Total Petroleum Hydrocarbons Total Suspended Solids Benchmarks - - - 15 mg/L 100 mg/L or 50 mg/O Parameter Code - 46529 NCOIL 00552 C0530 Not Applicable Footnotes from Part A also apply to Part B Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Permit Date: 11/1/2018-05/31/2021 SWU-245, last revised 11/1/2018 Page 2 of 3 FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES Q NO ❑ IF YES, HAVE YOU CONTACTED THE DEMLR REGIONAL OFFICE? YES 0 NO ❑ REGIONAL OFFICE CONTACT NAME: Z,hid Khan and Holiday Keen -Letter for Relief from Monthly Moritonng Attached for Reference Mail an original copy of this DMR including all "No Discharge" reports within 30 days of receipt of the lab results (or at end of monitoring period in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." Signature of Permittee Permit Date:11/1/2018-05/31/2021 - Date SWU-245, last revised 11/1/2018 Page 3 of 3 OO aceAnalytical Report of Analysis Cormetech, Inc. 11707 Steele Creek Rd Charlotte, NC 28273 Attention: Lanette Plyler Project Name: Charlotte Facility Stormwater Lot Number:VB21092 Date Completed:03/02/2020 03/03/2020 4:34 PM Approved and released by: Project Manager: Kelly M. Nance ANSI Vah9nNA-Mih1W Hop! A C C R E D I T E D TESTING,A99WONV The electronic signature above is the equivalent of a handwritten signature. This report shall not be reproduced, except in its entirety, without the written approval of Pace Analytical Services, LLC. Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 Tel:803-791-9700 Fax:803-791-9111 www.pacelabs.com Page 1 of 12 PACE ANALYTICAL SERVICES, LLC SC DHEC No: 32010001 NELAC No: E87653 NC DENR No: 329 NC Field Parameters No: 5639 Case Narrative Cormetech, Inc. Lot Number: VB21092 This Report of Analysis contains the analytical result(s) for the sample(s) listed on the Sample Summary following this Case Narrative. The sample receiving date is documented in the header information associated with each sample. All results listed in this report relate only to the samples that are contained within this report. Sample receipt, sample analysis, and data review have been performed in accordance with the most current approved NELAC standards, the Pace Analytical Services, LLC ("Pace") Quality Assurance Management Plan (QAMP), standard operating procedures (SOPs), and Pace policies. Any exceptions to the NELAC standards, the QAMP, SOPs or policies are qualified on the results page or discussed below. If you have any questions regarding this report please contact the Pace Project Manager listed on the cover page. Pace Analytical Services, LLC (formerly Shealy Environmetal Services. Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 2 of 12 PACE ANALYTICAL SERVICES, LLC Sample Summary Cormetech, Inc. Lot Number: VB21092 Sample Number Sample ID Matrix Date Sampled Date Received 001 001 Aqueous 02/20/20201024 02/21/2020 002 003 Aqueous 02/20/20201605 02/21/2020 (2 samples) Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 3 of 12 Inorganic non-metals Client:Cormetech, Inc. Laboratory ID:VB21092-001 Description: 001 Matrix: Aqueous Date Sampled:02/20/2020 1024 Date Received:02/21/2020 Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (pH - Field) SM 4500-H B-2011 1 02/20/2020 1024 MLK 1 (Temperature ) SM 2550E-2010 1 02/20/2020 1024 MLK 1 (TSS) SM 2540D-2011 1 02/25/2020 1923 MOM 46062 1 (SGT - HEM (n) 1664B 1 02/29/2020 1656 SMA 46508 CAS Analytical Parameter Number Method Result Q LOQ Units Run pH -Field SM 4500-H B-2 7.2 su 1 Temperature - Field SM 25506- 9.30 ° C 1 TSS SM 2540D- 36 5.0 mg/L 1 SGT - HEM (non -polar material) 1664E ND 5.0 mg/L 1 LOQ = Limit of Quantitabon B = Detected in the method blank E = Quantitation of compound exceeded the calibration range ND = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40% H = Out of holding time W = Reported on wet weight basis Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www pacelabs com Page 4 of 12 ICP-AES Client:Cormetech, Inc. Laboratory ID:VB21092-001 Description:001 Matrix: Aqueous Date Sampled:02/20/2020 1024 Date Received:02/21/2020 Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 200.7 200.7 1 02/26/20201832 KSH2 02/22/20201131 45794 CAS Analytical Parameter Number Method Result Q LOQ Units Run Copper 7440-50-8 200.7 0.053 0.010 mg/L 1 Lead 7439-92-1 200.7 ND 0.010 mg/L 1 Zinc 7440-66-6 200.7 0.085 0.020 mg/L 1 LOO = Limit of Quantitation B = Detected in the method blank E = Quantttation of compound exceeded the calibration range ND = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40% H = Out of holding time W = Reported on wet weight basis Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www pacelabs com Page 5 of 12 Inorganic non-metals Client:Cormetech, Inc. Laboratory ID: VB21092-002 Description: 003 Matrix: Aqueous Date Sampled:02/20/2020 1605 Date Received:02/21/2020 Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (pH - Field) SM 4500-H B-2011 1 02/20/2020 1605 MLK 1 (Temperature ) SM 2550E-2010 1 02/20/2020 1605 MLK 1 (TSS) SM 2540D-2011 1 02/25/2020 1923 MOM 46062 1 (SGT - HEM (n) 1664B 1 02/29/2020 1656 SMA 46508 CAS Analytical Parameter Number Method Result Q LOQ Units Run pH - Field SM 4500-H B-2 7.3 su 1 Temperature - Field SM 255013- 9.20 ° C 1 TSS SM 2540D- 8.2 2.5 mg/L 1 SGT - HEM (non -polar material) 1664E ND 5.0 mg/L 1 LOQ = Limit of Quantdation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range ND = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40% H = Out of holding time W = Reported on wet weight basis Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www pacelabs.com Page 6 of 12 ICP-AES Client:Cormetech, Inc. Laboratory ID:VB21092-002 Description: 003 Matrix: Aqueous Date Sampled:02/20/2020 1605 Date Received:02/21/2020 Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 200.7 200.7 1 02/26/20201853 KSH2 02/22/20201131 45794 CAS Analytical Parameter Number Method Result Q LOQ Units Run Copper 7440-50-8 200.7 ND 0.010 mg/L 1 Lead 7439-92-1 200.7 ND 0.010 mg/L 1 Zinc 7440-66-6 200.7 ND 0.020 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantdation of compound exceeded the calibration range ND = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40% H = Out of holding time W = Reported on wet weight basis Pace Analytical Services, LLC (formerly Shealy Environmental Services. Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www pacelabs com Page 7 of 12 Chain of Custody and Miscellaneous Documents Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 8 of 12 N u) v 0 Cr 0 3 Chain of Custody Record Shealy Env ronmental Services, Inc. 106 Vantage Point Drive West Columbia, So ;th Carolina 29172 Telephone No. (803) 791-97Q0 Fax No. (803) 791-9111 www.SYrea'ylab.mn Number •CIerd Report to Contant Sampler Printad %amel J ?.)wle Nc. iCarmetedi LaVU,Ryer AderRas Teteplivnv No. ! =ax Nv. i Em:u Wayb.1 ho. Page 1 of 1 G:y Stare I p (.'we Preservative 1 1 NA NA P.F. Number of Containers C7trrinttc yC I 1. Unprcc. 2 NeUHfZ%A 4. HNO3 7- ACH 5. M+ rC _ U t3otlle Proocl Nam: e 4 Rerervafiau Charlotte Fadfity SW S. H2SO4 6. Nip TWo, I I� !!ll ppqq �IJiI IPIII Prolac.Numner RDN.AmWr It Matr.x u I rn O ,� 01 + � �r � µ I!t�i�I� l�ilY l VB21092 Sample [U! L.N---,crlplMr � � N (Contaera-e for each sen* may ta! r-Whited rne) Date Tine r TAIDW iU f cr+crn t¢ L' F N KNr:2 X 003 �� G X X X X X X � r � I i t i 'Pipe CO2 No Discharge i Tim A•wnl TmnRr uirrr. Prir:r lASA n TgWrer''X +od TF. ern s:s�u�+e Cispceal GtC Reouiemems fPtease S`jecl!yj F slble '" latare ldenh3ca6on sttJ utl Lf Rug r tPlease EFe*I Rotten !o Clleot 9DWoosal b9 Lai on-Aezerd EI {�F°smm— Ve ❑Skin lrtltrnt Pois3n UH UnKnown 1. t - ed t y r S er L Uat rme to 1. Rocx jvod by 41.V7 Lare i Ole 4 A- 7 sad-. a egv4 9 by Deter Tlme 12. Re ed t>y C:utc Timc 12. 3. Rialinclshei i pa t i ime, Q. RkWved by Crate TIME l�; 90 ; l 4. nailnquleh- y Oats Irma a, LAoreto,6rtEtKi t,/y pate Time Note: All samples are retained for six weeks from receipt unless other ILAS Lki=ONLY J Ruceilri eniu. Temp. blank arran ernents are R�".jvud Cif ICA Cive.C,k) ,� I..1' [� N r]tw Paris � / n C 7 N F I1ec iva We (W-27.23'i PACE ANALYTICAL SERVICES. LLC 3ke. C,,.:w.R,nsti.rrr.:� tv: D:a[mar A,.v.r iri a':!4[tC ETxlnefaeu MI:1'yt Picld AnalysiS Recor-d - forth Carob r C:nmplilmicc r Amr- ' t --- �.�'��-j7� D1tr: ui�.ss fhtlir-oll-CrrwdyN: ,ti �--±� CtJ�— ..��n t FIT b;' SM 4b(It7H' IF201U 0 TrnaptrriNrc by .%N3 25W 0-2t111) Ir:6c.-t[� rscrc ifseetplr nat [gsplica6:e: -- . NOVA41811 Standard Cate. 5trudrrrl Aus1�9Claund �tettr t2f. Meter ID Sxn Sterrhyrrl Iri I 'ti% u1 i►'kaenrcd tom' 1 Trmp. Rr:xleryt 2 !'Jlsrt'Nila r'�im m, uts CLNIc. Thrc rrmp� 111 i"17 (51:1 IP,F) (Sl r) /Z �-�. NA N% ' NA NA NA NA NA NA HA - VA F ( 14A NA NA I yr NA - I NA Pxt-Analysis Chat SI�a1J3ru. .. i0 ' �• 7_t� ib� �` . ��} - ..°s[tl.. a-+ep:, i.rn6.nn.. «•e,ra ,e.ao,.•n �;r� Ssrpo ovk�wn u,,: SK.,,.lu ..+rot oA'J��...�,.,iwo.:�rs ... _ <_fol: r7ti'amh,-®rxur l0_ar,n,el n,w4aM "01 kt1 .. .�.s..iy.g.deG srhnl �,w.r eea ��:•�rrW1SUM:aswtsJ o,roe- r, di�,�ns. nd a.:y_.:,:,n t'Ca:d ttcyidral GIdOViNe by SAA 0416C.1 C:-2041 I .'6r C: 1—r :I-,uc-O aOt apldicabN:; i .�seikard 3iiadw-d Arwtyzes Buller DIT Nietrr Reads QC iNettrID tiampin4randsrd>li � COp G, 7i0te ID J11 I`navFDit� C! oi,weor: ___AuNlysia CErat 4andnrti' NA NA NA _ NA 4 NA A NA - - N NA ' NA' VA NA. - - VA — 1 Post-:5nsl3s_ ('betk SulndsM' Nh MA t'ert,w: rawhryj; n,r[ k 5m6[_ na,dlt per �x.,;7 i3 mwnu �,mJ'..a. h�,ypt rnr vile; nc spa: +. c n, -:', �.rnnr•t ud il:.e6!,d au hu.,Mrey..a rwt-.a.,.rr.a.'at. ay.wt,.d „wr Tdn.t•:nlQa.' uw�.r�vA xecayaw.•, _ Dis"'wed Osp�+cn by SM4MOO L h�.r6 F. L�rc if �:tG�a ilnL xppl7Whk: _ " - " i Mrnstyml Theoretical Dq Of �lticr tLl .1 na vs i>< _ S:LmplcrSl: ndard 113 1 t'Cqp, Mew%ored Tr-MV. ] Mcfer Reading AxsxrPatls C'ylnnnoyfa TimeQC t=c (-WL) (rlgl4) (rrr1 NA KA NA NA NA NA NA.- 0^:i}54sCalibrat:olt verf. ,:4.0 Sal. '0"cwrie nvrs: w yri:r-rwl i�iW, dt[uru '�L�: 4ntdc trlkaia y 1.,=e I:r:. e::,usrese�l; +knales u1Jrs:lu� "_— &aFr-: ixliurlm,.'irr:.,rwrrlL'Y�.arrne l�vsb,-�1C:C iGtl Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 10 of 12 PACE ANALYTICAL SERVICES, LLC "W.lv_avmrnlci`.:NJIAW ices.t`1c. tkncv'trn: Nem6cr; t+ltJU1:IBC•ld R:ey=tort Sample Receipt Chee.klist (SRC) Urec.ireL}&%AM"I'ala client: COW F_TECH Cooler lnsncctrd 1L4.'jjlltc; 147-,, 02.Qinl20 t Lal #: %B311ty2 Micwts or et ript ®S[Sl p ('tienu l.l'S V FcdEx other. Yes No _ :1, Were t.-taA seals orsent un the cooler? y'as �Ia NA 2. If custody;rids vrere sent, Weft thcv intact and untrrQkcn7 i l Strip M: 2M2(o Chlorine Strip TD: tVA I'rsted by, �1l.0 riginal 2.9 7.9 tenipelatcrc 'C upon receipt j Derivorl ((2wreected) tempernttrre upon receipt %Solid $nep-Cup• if): NA ,� h'.Ati� NA "C NA INA °C NA ,DNA •C - Method: 'OTctnperaturc Blank C]Agairsi Bottles IR Gun 10: 6 1R Gun Comction ;•actor. 0 IC' Method of coo.ant• 0 %'ct ice ❑ Ice PULk ❑ Dry lac U None i ❑ Yes I] No NANA 3. If tempera urc of any cooler extxxdc 16.0°C, was Prc�itrct Aianagcr Nutified? PM was Notified by. pho:ie i eraai:: face -la -face (circle one). [] Yes ❑ No e DNA •1. Is the commercial courieJ•'s packing slip attae.pkJ to tt.is form? 14 Ycs ❑ No '. Were .mper cuuody procedures (ralinguishoWreceived} fo:luwcyi? Yes Nu 5. Wnre sample ►1)s listed on the C(x-:;? ® Yes ❑ No 7. Wcrc sam le 09 listeJ cm all satnpl_ coriairtcrs': Yes No r Way cbJlectinn da-e $ timc listed oa the COC? Yes C No 9. 1Yas coilwAiun dare &. rime listed on 9.1 sample oa ttui ices? ® 10. Did all container lahel irtorraation (ID, date, time) agnc t� ith 1ha COL? . ❑ Yes n No I T WCtr'. tests to be petlur:ncc !isted on the 00C? ® Ycs ❑ No '2. Did H!I samples arrive in the propc. ccntainers for eacl: im antVar in good txmdirien (unaroken, lids on, eta)? _ ® Yas Ko 13. Was adequate w nple volume available? Yn ❑ Nu -14. Were all samples received within 4 the hald'utg time ar48 hotJts, whichever coot! fir_t'1 Y'es ®No 15. YVerc an .I mplac txnl:+;ners rnNsing{excess (cire;e onc) samples';�o(listed on COC? © Yee ❑ No 0 r%A 16. For VQA and RSK-175 samples, were bubbles present r: pea -size" ('r."or 6rrm in d:•arrn:t,rr) err any of the VOA trials? 0 Yes No NA 17. Wcrc a[: DR0lmetulv'nJt6ant samples rcccn+ed tit a pH of < 27 Y ! >•a NA I & Were 4cyanide "m ales roecived at a pH > 12 and sulfide sample receive[( at a pH > �-- ❑ Yes ❑ No Acablc ®NA 19. R crc a:l A' iliTKN'cyanidc� enal+'62S t< O +L) s mples rec of rexidua] ❑ Yes ❑ No ®NA 20. Wcrc client r�r►alits.'n yuestj (i.e., requested dilutions, MiNTSl) dea;gttat'.ons, etc... I cot:ectly transcribed frun; the COC into the comment suction in LIMS? Yes, flu' '2l. Vets the c -wtc number listed un the eonta.rev Ivbcl l if 2i o-e 4 NA1 Sa1dPle Pewee%-Atinn (Must be completed for any smnple(s) incormutly preservee or with headspucc.) 5a nple(s) �1r1 _were received incorrectly preserved and were zd usted a, ccxdittgly in satnple m-ceiving with NA ml..vf circle arm tf2Spa, H[NO3, HCL NaOl-1 using SR d tv.A I levee of prescrvatior. NA I1'more thAn one preservative is nee'LlUd, please note in the comments below. tplc(s) ?VA -- were received wits' iltibbics>6 :nett in dianic-er- Sa12t'riCg(3) on Were J'er:etved with TRC > 0.5 tno.J. (-If i,'19 is no and were at ,L-slyd accordirWy in sa.mplo rcccivinr with st�litut: t'titxs:dfate LN%S2G3) with Shealy iD: NA SK barcode labels appl E td by: JSH Date' 0212= r?G21t _. (::ommMAE — Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 11 of 12 PACE ANALYTICAL SERVICES, LLC Lanette Pl}per Cormctech 11707 Steele Creek Rd, Charlotte, NC 29A173 Comictech 11707 Steele Creek Rd. Charlotte. NC 28273 Stoimwater Qualitathm Monitoring Requimaicuts, 1" Scmi-annual event 2020 Febmary 20. 20210 - None 2-17aint I-! lnderate 4-Strong Pipe 001 ouUNH C.nlor- I Oder- 1 C:Iarit.y- 1 1:10aring SOWS- 1 Suspended Sulitla- 1 FORM- 1 Oil 51kcu- 1 Estimated Flo x: 2.0 GIs per minute r 0.20 Inches l:stimatai hvcntMischarge; 8 Hrs Estimated Total Flow: 950 GIs Pipe 002 outfall No INsebarge Pipe 003 outfitH ('Qlor- 2 Odor- 1 Clarity- 2 Floating Solids- l Suspended Solids- 2 Foatn- 1 Oil Shecn- I r tirnatcd RoNN: 1-0 (Tls Per minuic 10.20 Inches Estimated Event! Discharge: R Hr., 1"Airnutud Total Flow: 480 (Tls Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 12 of 12 Energy, Mineral and Land Resources ENVIRONMENTAL QUALITY October 5, 2016 CoaLogix SCR -Tech Attention: Mr. Brad Cummock, Owner/Contact Person 11707 Steele Creek Road Charlotte, North Carolina 28273 Dear Mr. Cummock: PAT MCCRORY (�,vennr DONALD R. VAN DER VAART sacrcra,}, TRACY" DAV(S Vircctor Subject: Relief from Monthly Monitoring NPDES Stormwater Permit NCG030000 Certificate of Coverage # NCG030617 11707 Steele Creek Road, Mecklenburg County, North Carolina We received a request for relief from monthly monitoring regarding levels of zinc and copper in stormwater from this site exceeding the benchmark limits of the NCG030000 general permit. The facility was inspected on September 28, 2016 by staff of this office accompanied by Ms. Lanette Plyler. Based on our inspection and the investigation of potential sources are not attributed by CoaLogix SCR -Tech, and Division is granting regulatory relief from the Tier Two response for copper and zinc benchmark exceedances. Upon receipt of this letter, the subject facility may continue the semi-annual analytical monitoring schedule as specified in the general pernut for the remainder of the current permit term. Your current permit is set to expire on October 31, 2017. Please note that this monitoring relief applies only to zinc and copper. Any benchmark limit exceedance of other parameters required by the permit will trigger the tiered response actions as described within the general permit. You must notify this office, in writing, within 5 business days if you become aware of any other significant source of copper or zinc at your facility that has potential to affect stormwater from the facility. The relief granted in this letter is contingent upon the current practices at this facility. If any practices should deviate from current activities and create significant stormwater exposure risk, this office reserves the right to withdraw this decision and reinstate the permit specified tiered response that may be warranted by any new circumstances. j S:arcol'NorthCarolina I Environmcnlal Lualib:' [.,mn*, Mineral .ndLand Rosourcts Nlooresrdle Regional Ofliie 1 61!1 Fast Center .Ave `ite i01 I tMwiesvd.e. NC 281 I i 704 66:1 1699 1' Relief from Monthly Monitoring CoaLogix SCR -Tech October 5, 2016 Page 2of2 Please retain and append this letter to your Stormwater Pollution Prevention Plan (SPPP) or permit. If you have any questions, comments, or concerns please contact our office at 704-663-1699. Sincerely, Zahid S. Khan, CPM, CPESC, CPSWQ Regional Engineer Land Quality Section Enclosure: Inspection Report cc'. Ms. Lanette Plyler, 11707 Steele Creek Road, Charlotte, NC 28273 Mr. Bradley Bennett, Stormwater Permitting Program, Certificate of Coverage NCG Compliance Inspection Report Permit: NCG030617 Effective: 12/12/12 Expiration: 1C/31/17 owner: Brad Cummock SOC: Effective: Expiration: Facility: CoaLogix SCR -Tech County: Mecklenburg 11707 Steele Creek Rd Region: Mooresville Charlotte NC 28273 Contact Person: Brad Cummock Title: Phone: 704-414-4614 Directions to Facility: System Classifications: Primary ORC: Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Date: 09/28/2016 Primary Inspector: Holliday Keen Secondary Inspector(s): Entry Time: 11 OOAM Certification: Exit Time: 12:00PM Zahid S Khan Reason for Inspection: Other Inspection Type Permit Inspection Type: (Metal Fabrication Stormwater Discharge COC Facility Status: Compliant Not Compliant Question Areas: a Storm Water (See attachment summary) Phone: Phone: Phone : Technical Assistance Page: 1 Permit: NCG030617 Owner - Facility: Brad Cummock fnspectlon Date: 09/28/2016 Inspection Type: Technical Assistance Reason for Visit: Other Inspection Summary: This inspection was conducted per request for technical assistance from Lanette Plyler. In November of 2015, analytical monitoring resulted in copper and zinc levels exceeding the benchmark limits specified in the general permit for NCG030000. These exceedances put Coalogix'in Tier Two monitoring and monthly analytical monitoring began in December of 2015. After investigation, Coalogix was unable to locate the source causing the stormwater to exceed the benchmark limits. During our inspection, we found that the site was well maintained and we were unable to locate the source of the copper and zinc causing exceedances in the analytical monitoring Because site conditions reflect compliance with all stipulations of general permit NCG030000, this site may return to Tier One montioring requirements. Page: 2 Permit: NGG030617 Owner - Facility: Brad Cummock Inspection Date: 09/2812016 Inspection Type: Technical Assistance Reason for Visit Other Analytical Monitoring Yes No NA NE Has the facility conducted its Analytical monitoring? ❑ ❑ ❑ # Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? ❑ ❑ IN ❑ Comment: Permit and Outfalls Yes No NA NE # Is a copy of the Permit and the Certificate of Coverage available at the site? i ❑ ❑ ❑ # Were all outfalls observed during the inspection? ❑ ❑ ❑ # If the facility has representative outfall status, is it properly documented by the Division? ❑ ❑ ❑ # Has the facility evaluated all illicit (non stormwater) discharges? E ❑ ❑ ❑ Comment: Qualitative Monitoring Yes No NA NE Has the facility conducted its Qualitative Monitoring semi-annually? ❑ ❑ ❑ Comment: Stormwater Pollution Prevention Plan Yes No NA NE Does the site have a Stormwater Pollution Prevention Plan? 0 ❑ ❑ ❑ # Does the Plan include a General Location (USGS) map? M ❑ ❑ ❑ # Does the Plan include a "Narrative Description of Practices"? ❑ ❑ ❑ # Does the Plan include a detailed site map including outfall locations and drainage areas? ❑ ❑ ❑ # Does the Plan include a list of significant spills occurring during the past 3 years? 9 ❑ ❑ ❑ # Has the facility evaluated feasible alternatives to current practices? ® ❑ ❑ ❑ # Does the facility provide all necessary secondary containment? ❑ ❑ ❑ # Does the Plan include a BMP summary? ®❑ ❑ # Does the Plan include a Spill Prevention and Response Plan (SPRP)? 0 El ❑ ❑ # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? ■ ❑ ❑ ❑ # Does the facility provide and document Employee Training? ■ ❑ ❑ ❑ # Does the Plan include a list of Responsible Party(s)? E n ❑ ❑ # Is the Plan reviewed and updated annually? 9 ❑ ❑ ❑ # Does the Plan include a Stormwater Facility Inspection Program? ❑ ❑ ❑ Has the Stormwater Pollution Prevention Plan been implemented? ❑ ❑ ❑ Comment: Page 3