Loading...
HomeMy WebLinkAboutNCG080431_2019 DMR_20201014 (2)Carolina Tank Lines, Inc. Mr. Ron Goras Post Office Box 2827 Burlington, NC 27216-2827 Analytical Testing Parameters OMICROBAC° Microbac Laboratories, Inc. - Fayetteville CERTIFICATE OF ANALYSIS K9A0273 Project Name: Stormwater sample - Semiannual Project / PO Number: N/A Received: 01 /17/2019 Reported: 01 /28/2019 Client Sample ID: Stormwater, grab Sample Matrix: Aqueous Collected By: Goras I Lab Sample ID: "' K9A0273-01 Collection Date: 01 /16!2019 9:00 Wet Chemistry Result RL Units Note Prepared Analyzed Analyst Method: EPA 1664 Rev. B Oil & Grease (SGT-HEM) <5.00 5.00 mg/L 01/23/19 1031 TAB Method: SM 2540 D-2011 Total Suspended Solids 6.50 4.17 mg/L 01/17/19 1028 MT Method: SM 2540 F-2011 Settleable Solids <0.10 0.10 mL/L Y 01/17/19 1019 MT Method: SM 4500 H+B-2011 pH at 25 °C 5.9 1.0 pH Units H 01/18/19 1117 CLB Definitions H: Analyte was prepared and/or analyzed outside of the analytical method holding time RL: Reporting Limit Y: This analyte is not on the laboratory's current scope of accreditation. Project Requested Certification(s) Microbac Laboratories, Inc. - Fayetteville 11 North Carolina DENR NPDES Report Comments Samples were received in proper condition and the reported results conform to applicable accreditation standard unless otherwise noted. The data and information on this, and other accompanying documents, represents only the sample(s) analyzed. This report is incomplete unless all pages indicated in the footnote are present and an authorized signature is included. Reviewed and Approved By: Jeanne Overstreet Client Relationship Specialist, Environmental Reported: 01 /28/2019 12:21 Microbac Laboratories, Inc. 2592 Hope Mills Rd I Fayetteville, NC 28306 1910.864.1920 p I www.microbac.com Page 1 of 3 u u 1 'K9AO273` Fayetteville Division 2592 Hope Mills Road — Fayetteville, NC 28306 (910) 864-1920 / 864-8774 fax p CHAIN OF CUSTODY RECORD PAGE 1 OF_I, Re lnqu 16 y. Dale Tllne Reeelvcd by. (Signature) Date Tlmc 3 4 ReTN,Iahed by. Dale Tame R—Wed W. 0M. Tlme 5 6 pH Field : Temp Field: Field Chlorine: Comments or Soecial Hazards: �6k6� IS DATA FOR REG. COMPLIANCE PURPOSE? NO YES WHICH: A,`n"v�;'� ^�,: e+:+w�...... �Tu _.-�..rx{F,ipo.u,`exv. xrrr-.�trr r:.rsa`<a�vartstrnx�vala+sxm!.s1F.ry..er<v_,.,... age2o 3 u *K9A0273* STORM WATER - QUALITATIVE MONITORING - CAROLINA TANK Z o� STORM SITE # DATE SAMPLED COLOR ODOR CLARITY FLOATING SOLIDS SUSPENDED SOLIDS FOAM OIL SHEEN EROSION OR DEPOSITION AT THE OUTFALL OTHER OBVIOUS INDICATORS OF STORMWATER POLLUTION 2 3 TOTAL RAINFALL (inches): o S u U