HomeMy WebLinkAbout20100076 Ver 1_Staff Comments_20100302Lucas, Annette From: Lucas, Annette [annette.lucas@ncdenr.gov] Sent: Wednesday, March 03, 2010 12:58 PM To: Homewood, Sue Cc: Annette Lucas Subject: 10-0076 Lion's Gate Townhomes Sue - I have looked at the plans for this project and I do not think it is a good idea to put the sand filter on the footprint of the wetlands as they have proposed. One issue is that we do not typically placement of BMPs in wetlands as meeting avoidance & minimization criteria. The other reason is that the BMP Manual requires that there be a minimum separation of 1' between the bottom of the sand filter and the SHWT. The sand filter design they show on Plan Sheet 5 is already up to 15' below the ground surface! I feel certain they will not be able to meet that criteria on the footprint of a wetland. Let me know if you want my help in crafting a hold bullet on that. Thanks, A Annette Lucas, PE NC Division of Water Quality - 401 Oversight/Express Unit 2321 Crabtree Boulevard, Suite 250 Raleigh, North Carolina 27604 Phone: (919) 715-3425 Fax: (919) 733-6893 Email correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties.