HomeMy WebLinkAboutNCG160122_DMR_20200518 Semi-annual Stormwater Discharge Monitoring Report (DMR)
for North Carolina DEMLR General Permit No. NCG160000 - Asphalt
Date submitted 05/18/2020
CERTIFICATE OF COVERAGE NO. NCG16 0122 SAMPLE COLLECTION YEAR 2020
FACILITY NAME APAC Atlantic,Inc.Plant#10 SAMPLE PERIOD Jan-June July-Dec
COUNTY Guilford or Monthly1 (month)
PERSON COLLECTING SAMPLES Mbargou Diop SECF'R /FDSCHARGINGTOCLASS ❑ORW I IHQW Trout IIIPNA
LABORATORY ENCo Lab Cert.# 591 I (Zero-flow Water Supply fSA
Comments on sample collection or analysis:
MAY 2 9 2020 1lOther Copper Branch
CEN1 F AL FILES PLEASE REMEMBER TO SIGN ON THE REVERSE -
GWR SECTION
Part A: Stormwater Benchmarks and Monitoring Results
No discharge this period?'
Outfall No. Date Sample 24-hour rainfall
Collected) amount, Total Suspended Solids
(mo/dd/yr) Inches
Benchmarks===> - - 100 mg/L or 50 mg/L4
001 04/30/2020 1.5 4.1
002 04/30/2020 1.5 4.2
1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall.
'For sampling periods with no discharge at any single outfall,you must still submit this discharge monitoring report with a check mark here.
'The total precipitation must be recorded using data from an on-site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge
4requirement. See General Permit text, Table 1, identifying the especially sensitive receiving water classifications where the more protective benchmark
applies.
Note: Results must be reported in numerical format. For example, do not report Below Detection Limit, BDL, <PQL, Non-detect, ND, or other similar non-
numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the
detection limit, reporting limit, quantitation limit, etc. in mg/L.
Note:If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text.
Permit Date:08/01/2019-05/31/2024 SWU-252, last revised 09/04/2019
Page 1 of 2
Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging> 55 gal of new oil per month.
I I No discharge this period?'
Outfall No. Date Sample 24-hour rainfall New Motor Oil or Hydraulic
Collected' amount, Non-polar O&G by EPA Oil Usage,Annual average
(mo/dd/yr) Inches3 1664(SGT-HEM) Total Suspended Solids gal/mo
Benchmarks===> - - 15 mg/L 100/L or 50 mg/L4 -
Footnotes from Part A also apply to this Part B
Note:If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text.
FOR PART A AND PART B MONITORING RESULTS:
• A SINGLE BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS.
• 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS.
• TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDANCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ❑ NO ❑
IF YES,HAVE YOU CONTACTED THE DEMLR REGIONAL OFFICE AS REQUIRED BYTHE PERMIT? YES ❑ NO❑
REGIONAL OFFICE CONTACT NAME:
Mail an original and one copy of this DMR, including all"No Discharge"reports, within 30 days of receipt of the lab results(or at end of monitoring period
in the case of"No Discharge"reports)to:
Division of Water Resources
Attn: DWR Central Files
1617 Mail Service Center
Raleigh, North Carolina 27699-1617
YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED:
"I certify, under penalty of law,that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to
assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system,or
those persons directly responsible for gathering the information,the information submitted is,to the best of my knowledge and belief,true,accurate, and complete. I
am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations."
05/18/2020
(Signature of Permittee) (Date)
Permit Date:08/01/2019-05/31/2024 SWU-252, last revised 09/04/2019
Page 2 of 2
Laboratories
Accurate. Timely. Responsive. Innovative.
102-A Woodwinds Industrial Court
Cary NC,27511
Phone: 919.467.3090 FAX: 919.467.3515
Tuesday, May 12, 2020
EI Group,Inc. (TH005)
Attn: Parker Alvis
2101 Gateway Center Blvd., Suite 200
Morrisville, NC 27560
RE: Laboratory Results for
Project Number: [none], Project Name/Desc:APAC Plant 10
ENCO Workorder(s): CD01480
Dear Parker Alvis,
Enclosed is a copy of your laboratory report for test samples received by our laboratory on
Monday, May 4, 2020.
Unless otherwise noted in an attached project narrative,all samples were received in
acceptable condition and processed in accordance with the referenced methods/procedures.
Results for these procedures apply only to the samples as submitted.
The analytical results contained in this report are in compliance with NELAC standards, except
as noted in the project narrative if applicable. This report shall not be reproduced except in
full,without the written approval of the Laboratory.
This report contains only those analyses performed by Environmental Conservation
Laboratories. Unless otherwise noted, all analyses were performed at ENCO Cary. Data from
outside organizations will be reported under separate cover.
If you have any questions or require further information, please do not hesitate to contact me.
Sincerely,
Sr/
05#/eopiezfrold
Bill Scott
Project Manager
Enclosure(s)
FINAL This report relates only to the sample as received by the laboratory,and may only be reproduced in full. Page 1 of 7
4111111
www.encolabs.com
SAMPLE SUMMARY/LABORATORY CHRONICLE
Client ID: Outfall#1 Lab ID: CD01480-01 Sampled: 04/30/20 08:30 Received: 05/04/20 13:00
Parameter Preparation Hold Date/Time(s1 preo pate/Time(sl Analysis Date/Time(sl
SM 2540D-2011 NO PREP 05/07/20 05/06/20 13:53 05/06/20 13:53
Client ID: Outfall#2 Lab ID: CD01480-02 Sampled: 04/30/20 08:45 Received: 05/04/20 13:00
Parameter preparation Hold Date/Time(s1 prep Date/Time(s1 Analysis Date/Time(s)
SM 25400-2011 NO PREP 05/07/20 05/06/20 13:53 05/06/20 13:53
FINAL This report relates only to the sample as received by the laboratory,and may only be reproduced in full. Page 2 of 7
(Erig 9
www.encolabs.com
SAMPLE DETECTION SUMMARY
Client ID: Outfall#1 Lab ID: CD01480-01
1
Analvte Results Flag MIA EQ1 pjits Method Notes
Total Suspended Solids 4.1 2.5 2.5 mg/L SM 2540D-2011
Client ID: Outfall#2 Lab ID: CD01480-02
Analvte Results Flan MD £QS Units Method Notes
Total Suspended Solids 4.2 2.5 2.5 mg/L SM 2540D-2011
FINAL This report relates only to the sample as received by the laboratory,and may only be reproduced in full. Page 3 of 7
(eJSJc )
www.encolabs.com
ANALYTICAL RESULTS
Description: Outfall#1 Lab Sample ID:CD01480-01 Received: 05/04/20 13:00
Matrix: Water Sampled:04/30/20 08:30 Work Order:CD01480
Project: APAC Plant 10 Sampled By:CLIENT
Classical Chemistry Parameters
^-ENCO Cary certified analyte[NC 591J
Analyte ICAS Numberl Results Flaq Units DF MDL PQ Batch Method Analyzed Notes
Total Suspended Solids^ 4.1 mg/L 1 2.5 2.5 0E06011 SM 2540D-2011 05/06/20 13:53 DM)
Description: Outfall#2 Lab Sample ID:CD01480-02 Received: 05/04/20 13:00
Matrix: Water Sampled:04/30/20 08:45 Work Order:CD01480
Project: APAC Plant 10 Sampled By:CLIENT
Classical Chemistry Parameters
^-ENCO Cary certified analyte[NC 591J
pnalvte ICAS Numberl Results Flaq Units Q P121. pQ Batch Method Analyzed jay Notes
Total Suspended Solids^ 4.2 mg/L 1 2.5 2.5 0E06011 SM 2540D-2011 05/06/20 13:53 DMJ
FINAL This report relates only to the sample as received by the laboratory,and may only be reproduced in full. Page 4 of 7 I
(eiSJc )
re)
:
www.encolabs.com
QUALITY CONTROL DATA
Classical Chemistry Parameters-Quality ControlII
Batch 0E06011-NO PREP
Blank(0E06011-BLK1) Prepared&Analyzed:05/06/2020 13:53II
Spike Source %REC RPD
Analvte Result Flag P12L Units Level Result %REC Limi RPD Limit Notes
Total Suspended Solids 2.5 U 2.5 mg/L
LCS(0E06011-BS1) Prepared&Analyzed:05/06/2020 13:5311
Spike Source %REC RPD
Analvte Result Rao P91 Units Level Result %REC Linita RPD Limit Notes
Total Suspended Solids 95 2.5 mg/L 100 95 80-120
Duplicate(0E06011-DUP1) Prepared&Analyzed:05/06/2020 13:53
Source:CD01901-01
Spike Source %REC RPD
Analvte Result Flaa POL Units Level Result %REC Limits RPD Limit Notes
Total Suspended Solids 520 50 mg/L 450 15 20
Duplicate(0E06011-DUP2) Prepared&Analyzed:05/06/2020 13:53
Source:CD01901-02 1
Spike Source %REC RPD
Analvte Result Flag PDL Units Level Result %REC imi RPD Limit Notes
Total Suspended Solids 700 50 mg/L 680 4 20
FINAL This report relates only to the sample as received by the laboratory,and may only be reproduced in tun. Page 5 of 7
sax co
www.encolabs.com
FLAGS/NOTES AND DEFINITIONS
B The analyte was detected in the associated method blank.
D The sample was analyzed at dilution.
J The reported value is between the laboratory method detection limit(MDL)and the laboratory method
reporting limit(MRL),adjusted for actual sample preparation data and moisture content,where applicable.
U The analyte was analyzed for but not detected to the level shown,adjusted for actual sample preparation
data and moisture content,where applicable.
E The concentration indicated for this analyte is an estimated value above the calibration range of the
instrument.This value is considered an estimate.
MRL Method Reporting Limit.The MRL is roughly equivalent to the practical quantitation limit(PQL)and is
based on the low point of the calibration curve,when applicable,sample preparation factor,dilution
factor,and,in the case of soil samples,moisture content.
PQL PQL: Practical Quantitation Limit. The PQL presented is the laboratory MRL.
N The analysis indicates the presence of an analyte for which there is presumptive evidence(85%or greater
confidence)to make a"tentative identification".
P Greater than 25%concentration difference was observed between the primary and secondary GC column.
The lower concentration is reported.
[CALC] Calculated analyte-MDL/MRL reported to the highest reporting limit of the component analyses.
FINAL This report relates only to the sample as received by the laboratory,and may only be reproduced in full. Page 6 of 7
I 10775 Cenral Port Or. 4810 Executive Park Court,Suite ii t 102 A Woodwinds Industrial Ct.
Orlando.FL 32824 Jacksonville.FL 32210.6069 Cary,NC'27511
(407)626.5314 (904)296.3007 Fax(904)296-0210 (0 19)467.3090 Fax(919)467.3515 Page of _---
,l _
Client Name Project Number Requested Analyses Requested Tumaro
El Gt t ,trig. fTHC Inane] Tulles
aildrs Project Namesc Note Rush requests suhp. of
2101 Gateway Center Blvd.,Suite 20t} APAC Plant 10 acceptance tac:i 1
City/ST/Zip PO#t Billing Into
Morrisville,CSC 270 p �.Standard-
Tel Fax Reporting Contact ca
(919)657-7500 Parker Awls 3 Expedited
eq-
Sampler(s)blame,Affiliation(Print) Wing Contact pie
Patter Awls s. tO Due 1 I
Sampler(s)Signature Site Location f T me Zone Lob Workardor
Preservation(See Codes)(Combine as necessary)
dam R Sample 10)Fi Id IJen1 hcpuor i Ce'lect,00 Dew Tangy n ,,,,,,,iv,,,, Sample CuMMet15
r O c.,4- / F. .- 44 •fit ' `i.s WA
_. _. . � jP �
F
.1F
y<--Total#of Containers
:::
y D twriime Rtziirtt}uishetl9y t?nt ma RecarYadTUatef time
cial He& equirem nts Relinquished key,. "'""+ ;, Date/.1re? Received Date/Time
Relinquished By .-->'"' +Oateirime received Ely DatetTitne
Cooler#'s d Temps on ritece,pt Condition t! Receipt
1 t 1_ _ U �
__Acceptable , cc: piatiiet
Matrix.GW-Groundwater SO-Soil OW-Drinking Water SE Sediment.SW-Surface Water WW-Wastewater A-Air 0-Otter(detail in comments) Preservation:1-Ice H-NC) N-HNO3 S-t12604 140-( H 0-Other(detail in comments)
Note:All samples submitted to ENCO Labs are in accordance with the terms and conditions listed arm the reverse of this lorrzt<unless prior written agreements exist