Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0002648_Monitoring - 07-2020_20200819 (2)
`4 rGi M NDMR 05-16 NON -DISCHARGE MONITORING REPORT (NDMR) Page I of Permit No.: WQ0002648 Facility Name: Seagrove -Utah Metropolitan Water District WWTF County: Randolph Month: July Year: 2020 PPI: 001 Flow Measuring Point: ❑ Influent I] effluent ❑ No flow generated Parameter Monitoring Point: ❑ Influent 121 Effluent ❑ Groundwater Lowering ❑ Surface water Parameter Code 11, 50050 00310 00916 00940 50060 31616 00927 00610 00626 00620 00600 00400 00665 00931 00929 70300 U O a) E p p O E i FU - O m 2 c E + Z Z O , ~ Z `E O i 0 d 7 OO .0 Q E '0 a w 'O OO OO N N� 24-hr hrs GPD mg/L mg/L mg/L mg/L #I100 mL mg/L mg/L mg/L mg/L mgiL su mgiL Ratio mg/L mg/L 1 06:00 8 12,964 0.8 7.1 2 0600 8 13,088 <3 00 11.2 83 1.1 <1 6.73 <0 100 1.04 276 28.6 74 6.77 863 665 966 3 0600 8 13,447 0.9 7 2 4 06:00 8 13,282 0.6 7 5 14:00 1 13,337 1 0.7 1 7.2 6 06:30 8 13,122 0.7 7.1 7 0600 8 12,898 0.6 7 8 06.30 8 12,704 0.7 6.9 9 06:30 8 12,907 0.9 7.1 10 06:30 8 13,064 0.7 71 11 05:30 5 13,296 0.7 7 12 14:00 2 13,341 0.6 7 13 06.30 8 12,963 0.7 7 14 0630 8 12,884 0-8 7.2 15 06:30 8 12,761 O 7 7.1 161 06:30 8 12,842 0.7 1 7 17 05:30 9 12,683 0.8 7 18 16:00 2 13,714 0.5 6.8 19 07:00 5 12,895 0.6 6.5 20 06:30 8 12,926 0.6 7.1 21 06:30 8 12,791 O.7 7 221 06:00 8 12,834 0.8 6.9 23 0630 8 12,901 0.7 7.2 24 0630 8 13,163 0.6 7 25 06:00 8 13,742 0.5 68 26 14:00 2 13,519 0.6 7.1 27 06:30 8 12,989 6 7 281 06:30 8 12,857 0-7 6.9 291 05:30 8 12,742 0.4 6.7 301 05:45 8.5 12,837 0.8 7 311 0530 8 12,918. 0.8 6.9 Average: 13,046 0.00 11.20 2.68 0.87 1_00 6.73 0.00 1.04 27.60 28.60 6.77 863 66,50 966.00 Daily Maximum: 13,742 3.00 11.20 8300 6.00 1.00 6.73 0.10 1,04 27.60 2&60 7.40 6.77 8.63 66.50 966.00 Daily Minimum 12,683 3.00 11,20 83.00 0.40 1.00 6.73 0.10 1.04 27.60 28.60 6.50 1 6.77 863 66.50 1 966.00 Sampling Type Recorder Composite Grab Composite Grab Grab Grab Composite Composite Composite Composite Grab I Composite Calculated Grab Composite Monthly Limit Daily Limit: 80,000 �4X' Sample Frequency Continuous 4 X Year ear 3 X Year 5 X Week 4 X Year 4 X Year 4 X Year 4 X Year 4 X Year 4 X Year 5 X Week 4 X Year 4 X Year 4 X Year 3 X Year `A FORM NDMR 05-16 NON -DISCHARGE MONITORING REPORT (NDMR) Page d of 3 Permit No.: W00002648 Facility Name: Seagrove -Utah Metropolitan Water District WWTF County: Randolph 7Month: J t Year:l,G°?,4: PPI: 001 Flow Measuring Point: ❑ Influent Effluent L No flow generated Parameter Monitoring Point: C Influent E Effluent ❑ Groundwater Lowering ❑ Surface Water Parameter Code —i 00530 p > V af O �, H N c O O 4)m y c a F- N <n to 24-hr I hrs ni 1 2 0600 8 8.3 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Average: Daily Maximum: Daily Minimum Sampling Type Composite Monthly Limit Daily Limit: Sample Frequencyl 4 X Year w FORM: NDMR 05-16 NON -DISCHARGE MONITORING REPORT (NDMR) Page __a_ of Sampling Person(s) Certified Laboratories Name: Name: Name: Name: Does all monitoring data and sampling frequencies meet the requirements in Attachment A of your permit? O Compliant ❑ Non -Compliant If the facility is non -compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the non-compliance and describe the corrective action(s) taken. Attach additional sheets if necessary. Operator in Responsible Charge (ORC) Certification Permittee Certification ORC: LARRY T. CHILTON Permittee: SEAGROVE/ULAH METROPOLITAN WATER DISTRICT Certification No.: 2WW-10681 SI-28234 Signing Official: MICHAEL T. WALKER Grade: 2 Phone Number: 336-302-3782 Signing Official's Title: SECRETARY Has the ORC changed since the previ DMR? ❑ yes 21 No Phone Number: 336-873-9055 Permit Expiration: 9/30/2020 / - / _ 202-6 �^ , Signature Date Signature Date By this signature, I certify that this report is accurrate and complete to the best of my knowledge. I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that all qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations. Mail Original and Two Copies to: Division of Water Resources Information Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 FORM: NDAR-1 05-16 NON -DISCHARGE APPLICATION REPORT (NDAR-1) Page --/ of X No.: Q111 . .• • ••• . •• • . / 1 Did irrigation occur t Area ; . at this facility? Cover Crop:_Cover I`1 �(, Crop: Z YES NO Hourly Rate (in):'! Hourly Rate (in): Hourly Rate Hourly Rate (in): IIRate Annual ��{�Annual Rate (in): Annual IRate (in)-, ... •. • �� •, •• � • .. '. • �11111 .. rw©�� • .. '. • ® MM= ®_ • • 111 f f • i 1 ---- ®S®� ---- Monthly Loading:%////// ! ti 14. t i n c i T .. %//////%%//////i • t %///////. %////////.%///////, %/////// fORK NDAR•1 05-16 NON -DISCHARGE APPLICATION REPORT (NDAR-1) PageQ, of a Did the application rates exceed the limits in Attachment B of your permit? I] Compliant ❑ Non -Compliant Were adequate measures taken to prevent effluent ponding in or runoff from the sites? (] Compliant ❑ Non -Compliant Was a suitable vegetative cover maintained on all sites as specified in your permit? 21 Compliant ❑ Non -Compliant Were all setbacks listed in your permit maintained for every application to each permitted site? El Compliant ❑ Non -Compliant Were all freeboards maintained in accordance with the specified freeboard heights in your permit? O Compliant ❑ Non -Compliant If the facility is non -compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the non-compliance and describe the corrective action(s) taken. Attach additional sheets if necessary. Operator in Responsible Charge (ORC) Certification 11 Permittee Certification I ORC: LARRY T. CHILTON Certification No.: 2WW-10681 SI-28234 Grade: 2 Phone Number: 336-302-3782 Has the ORC changed since the previous NDAR-1? ❑ Yes O No Signature By this signature, I certify that this report is accurrate and complete to the best of my knowledge. Permittee: SEAGROVE/ULAH METROPOLITAN WATER DISTRICT Signing Official: MICHAEL T. WALKER Signing Official's Title: SECRETARY Phone Number: 336-873-9055 Permit Exp.: 9/30/20 -�k0 Date Signature Date I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that all qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations. Mail Original and Two Copies to: Division of Water Resources Information Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617