HomeMy WebLinkAboutSW6201003_Calcs (Antiflotation)_202010081617 VAR Ph IV
Pond #1
Antiflotation Calculation
Input Data
Safety Factor:
1.50
Top Width of Riser (ft)
3.00
Top Length of Riser (ft)
4.00
Thickness of Riser (ft)
0.50
Thickness of Bottom of Riser (ft)
0.50
Top of Riser (ft)
82.00
Invert of Riser (ft)
78.50
Volume of Riser (cf)
27.00
Unit Weight Of Concrete (lb/cf)
150.00
Unit Weight of Water (lb/cf)
62.40
Block Height (ft)
0.00
Block Width (ft)
2.00
Block Length (ft)
3.00
Output
Fw (Uplift Force, lb)
2620.80
Fc (Weight of Concrete,lb)
4050.00
Design Volume (cf)
27.00
Design Safety Factor
1.55
Volume OK
1617 Antiflotation.xls 10/8/2020