Loading...
HomeMy WebLinkAboutSW6200905_Pipe 2 calcs_20201008Culvert Report Hydraflow Express Extension for Autodesk® Civil 3D® by Autodesk, Inc. Currin Hill - Pipe 2 Invert Elev Dn (ft) = 233.50 Calculations Pipe Length (ft) = 50.00 Qmin (cfs) Slope (%) = 4.12 Qmax (cfs) Invert Elev Up (ft) = 235.56 Tailwater Elev (ft) Rise (in) = 18.0 Shape = Circular Highlighted Span (in) = 18.0 Qtotal (cfs) No. Barrels = 1 Qpipe (cfs) n-Value = 0.012 Qovertop (cfs) Culvert Type = Circular Concrete Veloc Dn (ft/s) Culvert Entrance = Groove end projecting (C) Veloc Up (ft/s) Coeff. K,M,c,Y,k = 0.0045, 2, 0.0317, 0.69, 0.2 HGL Dn (ft) HGL Up (ft) Embankment Hw Elev (ft) Top Elevation (ft) = 237.72 Hw/D (ft) Top Width (ft) = 32.00 Flow Regime Crest Width (ft) = 50.00 El ow (t) zMM z9M 2MM 235M 234M Currin Hill - Pipe 2 Wednesday, Sep 23 2020 = 8.57 = 8.57 = (dc+D)/2 = 8.57 = 8.57 = 0.00 = 5.21 = 5.99 = 234.82 = 236.69 = 237.32 = 1.18 = Inlet Control Hri Depth iftl 2.44 1.44 0.44 -OM -1 56 - 56 232A0 i i i i i i i i i i i i i i i-3M 0 5 10 15 225 3D 35 40 45 50 55 60 65 70 QrWffctdVfft HGL Embank REach (t)