Loading...
HomeMy WebLinkAboutWQ0004059_Compliance Evaluation Inspection_20170711Compliance Inspection Report Permit: WQ0004059 Effective: 01/18/08 Expiration: 12/31/16 owner: Sugarloaf Utility Inc SOC: Effective: Expiration: Facility: Atlantic Station WWTF County: Carteret 915 W Fort Macon Rd Region: Wilmington Atlantic Beach NC 28512 Contact Person: Joseph A Lawrence Title: ORC Phone: 252-393-8720 Directions to Facility: System Classifications: WW3•, Primary ORC: Joseph A Lawrence Secondary ORC(s): On -Site Representative(s): Certification: 6418 Phone: 252-393-8720 Related Permits: WQ0018525 Barnes Environmental Waste & Hauling Inc - Barnes Environmental Residuals Land Application Program Inspection Date: 07/11/2017 EntryTime: 10:OOAM Exit Time: 11:15AM Primary Inspector: Chad Coburn Phone: 910-796-7379 Secondary Inspector(s): Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: High Rate Infiltration Facility Status: Compliant ❑ Not Compliant Question Areas: Treatment Flow Measurement -Effluent Treatment Flow Measurement -Influent Miscellaneous Questions Treatment Flow Measurement -Water Treatment Treatment Clarifiers Use Records Treatment Disinfection End Use -Infiltration Treatment Flow Measurement Treatment Return pumps 0 Standby Power (See attachment summary) Page: 1 Permit: WQ0004059 Owner - Facility: Sugarloaf Utility Inc Inspection Date: 07/11/2017 Inspection Type : Compliance Evaluation Reason for Visit: Routine Inspection Summary: Inspection Summary: A facility compliance inspection was conducted on July 11, 2017. The main power was terminated and the auxiliary generator provided power to the plant. The operator received telemetry notification of the power loss. The closest rotary field dosed properly. The permit requires composite sampling for Chloride, BOD5,TSS,Ammonia Nitrogen, Nitrate, & TDS. Operations staff are now sampling effluent via composite sampling per the permit. Page: 2 Permit: WQ0004059 Owner - Facility: Sugarloaf Utility Inc Inspection Date: 07/11/2017 Inspection Type : Compliance Evaluation Reason for Visit: Routine Type Yes No NA NE Single Family Spray, LR ❑ Infiltration System ❑ Lagoon Spray, LR ❑ Reuse (Quality) ❑ Activated Sludge Spray, LR ❑ Activated Sludge Drip, LR ❑ Activated Sludge Spray, HR ❑ Single Family Drip ❑ Recycle/Reuse ❑ Treatment Yes No NA NE Are Treatment facilities consistent with those outlined in the current permit? 0 ❑ ❑ ❑ Do all treatment units appear to be operational? (if no, note below.) 0 ❑ ❑ ❑ Comment: Treatment Flow Measurement -Influent Yes No NA NE Is flowmeter calibrated annually? ❑ ❑ 0 ❑ Is flowmeter operating properly? ❑ ❑ 0 ❑ Does flowmeter monitor continuously? ❑ ❑ ❑ Does flowmeter record flow? ❑ ❑ ❑ Does flowmeter appear to monitor accurately? ❑ ❑ ❑ Comment: Treatment Flow Measurement -Water Use Records Yes No NA NE Is water use metered? ❑ 1:10 ❑ Are the daily average values properly calculated? ❑ ❑ 0 ❑ Comment: Treatment Flow Measurement -Effluent Yes No NA NE Is flowmeter calibrated annually? 0 ❑ ❑ ❑ Is flowmeter operating properly? ❑ ❑ ❑ Does flowmeter monitor continuously? ❑ ❑ ❑ Does flowmeter record flow? ❑ ❑ ❑ Does flowmeter appear to monitor accurately? ❑ ❑ ❑ Comment: The flow meter was calibrated on March 31, 2017 by Delta Systems Environmental Calibrations Standby Power Yes No NA NE Is automatically activated standby power available? 0 ❑ ❑ ❑ Page: 3 Permit: WQ0004059 Owner - Facility: Sugarloaf Utility Inc Inspection Date: 07/11/2017 Inspection Type : Compliance Evaluation Reason for Visit: Routine Is generator tested weekly by interrupting primary power source? ❑ ❑ ❑ Is generator operable? ❑ ❑ ❑ Does generator have adequate fuel? 0 ❑ ❑ ❑ Comment: Treatment Clarifiers Yes No NA NE Are the weirs level? 0 ❑ ❑ ❑ Are the weirs free of solids and algae? ❑ ❑ ❑ Is the scum removal system operational? ❑ ❑ ❑ Is the scum removal system accessible? ❑ ❑ ❑ Is the sludge blanket at an acceptable level? ❑ ❑ ❑ Is the effluent from the clarifier free of excessive solids? ❑ ❑ ❑ Comment: Treatment Return pumps Yes No NA NE Are they in place? 0 ❑ ❑ ❑ Are they operational? 0 ❑ ❑ ❑ Comment: Treatment Disinfection Yes No NA NE Is the system working? 0 ❑ ❑ ❑ Do the fecal coliform results indicate proper disinfection? ❑ ❑ ❑ Is there adequate detention time (-30 minutes)? ❑ ❑ ❑ Is the system properly maintained? ❑ ❑ ❑ If gas, does the cylinder storage appear safe? ❑ ❑ ❑ Is the fan in the chlorine feed room and storage area operable? ❑ ❑ 0 ❑ Is the chlorinator accessible? ❑ ❑ ❑ If tablets, are tablets present? ❑ ❑ ❑ Are the tablets the proper size and type? ❑ ❑ ❑ Is contact chamber free of sludge, solids, and growth? ❑ ❑ ❑ If UV, are extra UV bulbs available? ❑ ❑ ❑ If UV, is the UV intensity adequate? ❑ ❑ ❑ # Is it a dual feed system? ❑ ❑ ❑ Does the Stationary Source have more than 2500 Ibs of Chlorine (CAS No. 7782-50-5)? ❑ ❑ ❑ If yes, then is there a Risk Management Plan on site? ❑ ❑ ❑ If yes, then what is the EPA twelve digit ID Number? (1000- If yes, then when was the RMP last updated? Comment: Page: 4 Permit: WQ0004059 Owner - Facility: Sugarloaf Utility Inc Inspection Date: 07/11/2017 Inspection Type : Compliance Evaluation Reason for Visit: Routine End Use -Infiltration # Is the application High Rate or Low Rate? Are buffers maintained? Are any supply wells within the CB? Are any supply wells within 250' of the CB? Is municipal water available in the area? Are GW monitoring wells required? Are GW monitoring wells located properly w/ respect to RIB and CB? Are GW monitoring wells properly constructed, including screened interval? Is a usable green area maintained? Is the disposal site acceptable? Is the distribution equipment acceptable? Is the disposal site free of ponding? Is the disposal site free of breakout? Are the disposal sites free of solids, algae, etc.? Do the records show that the fields are properly maintained? Are the disposal sites free of vegetation? Do any surface water features appear to be adversely impacted by GW discharge? No chemicals or rototiller used to eliminate vegetation, solids, algae, etc.? Comment: There is a small amount of vegetation growinq on the sand within the rotor distributors. Yes No NA NE High Rate ❑■❑❑ ■❑❑❑ ■❑❑❑ ■❑❑❑ ❑❑❑■ ❑❑❑■ ■❑❑❑ ■❑❑❑ ■❑❑❑ ■❑❑❑ ■❑❑❑ ❑❑❑■ ❑■❑❑ Page: 5