Loading...
HomeMy WebLinkAbout20070933 Ver 2_Meeting Request Review_20200930ID#* 20070933 Version* 2 Regional Office * Raleigh Regional Office - (919) 791-4200 Reviewer List* Stephanie Goss Pre -Filing Meeting Request submitted 9/30/2020 .............. -........_ I ...................-.................................._......_......_..................................................................... Contact Name * Kim Hamlin Contact Email Address* Project Name* Project Owner* Project County* Owner Address: khamlin@sageecological.com Cadenza Lane Culvert Rose Hall HOA Wake Street Address 11320 Moonsprite Way Address Line 2 oty Raleigh Fbstal / Zip Code 27114 Is this a transportation project?* r Yes r No Type(s) of approval sought from the DWR: W 401 Water Quality Certification - r 401 Water Quality Certification - Regular Express ❑ Individual Permit F Modification ❑ Shoreline Stabilization Does this project have an existing project ID#?* r Yes r No Please list all existing project ID's associated with this projects.* DWQ EXP #07-0933 State / Rovince / Region NC Country USA Do you know the name of the staff member you would like to request a meeting with? Please give a brief project description below.* The project involves correcting/improvements to a perched corrugated aluminum culvert at an existing neighborhood road crossing. The proposed project includes adding a concrete baffle and larger rip rap to create a 12- inch bury of the culvert, improving slopes at the culvert inlet and outlet, and improving the riprap dissipator pad at the culvert outlet. Please give a couple of dates you are available for a meeting. 10/ 14/2020 10/ 15/2020 Please attach the documentation you would like to have the meeting about. Culvert Documents 5-20.pdf 862.27KB Letter - NCDOT 84-inch culvert 7-21-20.pdf 83.42KB pdf only By digitally signing below, I certify that I have read and understood that per the Federal Clean Water Act Section 401 Certification Rule the following statements: • This form completes the requirement of the Pre -Filing Meeting Request in the Clean Water Act Section 401 Certification Rule. • I understand by signing this form that I cannot submit my application until 30 calendar days after this pre -filing meeting request. • I also understand that DWR is not required to respond or grant the meeting request. Your project's thirty -day clock started upon receipt of this application. You will receive notification regarding meeting location and time if a meeting is necessary. You will receive notification when the thirty -day clock has expired, and you can submit an application. Signature mtq #ft Submittal Date 9/30/2020 Reviewer Meeting Request Decision Has a meeting been scheduled?* 4 Yes 0 NO JUL 03,2007 04:58P B. Scott Mitchel. 5770875 page 2 ,Michael F. P wlty. Uuvnmor Vv'iilrmt 5 FMif., Secrelctry Noah Carolina Depatirttmt Of EnVjfGrM-.fl: tu,d Natural RtfLurcos & 6;. i- i; a June'25, 2007 Honeycutt ESrates, C,I,C Attn, Mr, Rusty Ammons 318 West Millbrook Road Raleigh, NIC 27609 Subject Property: Rose Hall Subdivision, Phase 2 Cedar Creek [030401, 27-18-(1), WS-IV, NSW] Cnleq.l H Sullins, Director PlYwon of Warcr Quality DWQ EXP No. 07-0933 Wake County APPROVAL OF 401 WATER QUALITY CERTIFICATION .e.NA AUTHORIZATION CERTIFICATE PER THE NEUSE RIVER BUFFER PROTECTION RuLES (15A IVCAC 2B ,Q233) WITH ADDITIONAL CONDITIONS - E1ipjwsS' REYlEW PRot,j?AM Dear Mr, Ammons: Y.,,,u ha-e ow approval, in =ccrdance wiTh the attached conditions and those fisted below., to place fill within o- otherwise impact 7,299 syjul a feet f ft) of Zone 1 of the protected riparian buffers, 3,248 square feet W) of Zone 2 of the protect;d riparian buffers, and [48 linear leer of stream for the purpose of constructing the residential subdivision. as described within your Pre-wristruction Noti£;�tion Appllet cla dated May 24, 2007 and additional intormation received on June 6, 2007 and June 21., 2007, The impacts are covered by General Water (duality Certification Namber(s) 3627 (GC3627'i. The Certifications) allow ytlL. to use Natiom,,ide 1'errnit(s) - W I4 when issbed by the US Amly Corps of Engineers (USAC:E), In additiori, you should obtain or otherwise comply with any other regtiired federal, state or local permits before you go ahead with your Pt-0ject including (hut not limited to) Erosion and Sediment Control, and Non-dis;harge regulations. Also, this approval to proceed with your proposed isnpaets or to conduct impacts to waters As depicted in your stpplica,tion shall expire upolr expiration of the 404 Permit. This approval is for the purpose and design that you described it, your application, if you change yo+ar project, ,you must notify us and you may i� required to send us a new application. If the property is at-ld, the new owntr must be given a copy of this Certification and approval letter and is thereby responsible for complying with all conditions. If total f:l1s for this project now or in the ftsture) exceed one acre of wetland or 150 linear feet of stream, compensatory mitigation may be fequired as described in 15A NCAC-214.050b (h). This approval requires you to follow the conditions lister[ In the attached Water Quality !Certifications (C:C 3627) and any additional conditions listed below. 401 Uversight/Expre.-4 Rtvicw Pcrmtrting Unit i bSCf Mail 9er, Mc Coll-r, RtlleiBY. North Carolina 27699.1(iso 2321 Crabtr:e aaulevar3, suite 250Raleigh, Norh Cuohns 1?5,)t Phone• 919.733•178b1' FAX 414.737.6993 ! Int.-tzter ixro rfh2e.enr;larr rtr.u�+.•�wsdanl; ,'Ln i grjal GoportunilyiAffrnnativ: Action Ernpioyer— 501/0Rcycled/l D% Post Consumer !raper - �i,� Caro inN �'r+f�rx�l�ly ,NL 03, 2007 04 :59P B. Scott Mitct+.ei 5770875 page 3 Honeycutt Estates, L.t,C Page 2 of 4 June 25, 2007 The Additional rnnditionr of the Certiftentina are:: 1. Impacts Approved The following, impacts cue hereby approved as long as ail of the other specific. and general conditions of this Certification are met, No other Impacts are approved including incidental impacts., I>•P : Amount 'Urlrs! I Reference Stream erennia! 14$ Iihear feet PCN rage $ of 12 Buffers 40ne 1 7,229 (SF) I PO ,a a 11 of 12 buffers zona 2 3,248 (SF) 11 of 12 2. No Was-e, Spoil, Solids, or fill of Anv Kind No waste, spoil, solids, or till of any kind shall %cur in wetlands, waters, or riparian areas beyond the footprint of the impacts depicted in 'the Pre-ConstrLiction Notification. All ;,anstnJctipn activities, including the design, installation, operation, and maintenance of sediment and erosion control Best Management Practices, shall be perforniud so that no violation; of state water quality standards, statutes, or rules occur, Erosion and sediment runtrul practices must be in full compliance with all specifications hove -ruing the proper design, installation and operation and maintenance of such Host Management Practices in order to protect surface waters standards: a, The erosion and sediment control measures for the project must be designed, installed, operated, and maintained in accordance with the most. recent version of the North Carolina Sedlnrenl and lrosion Control Planning and Design Manual. b, The design, installation, operation, and maintcnavec oFthe sediment and crosioncontrol measures must be such that they equal, or exceed, the requirements specified in the most riXont version of the North Carolina Sediment mid Erosion Control Manua?. The devices shall be maintained on all construction sites, borrow sites, and waste pile (spoil) projects, Including contractor -owned or leased borrow pits associated with the project, Sufficient materials required far stabilization and/or repair of erosion control measures and stor mwater routing and treatment shall be on site at all times, 4. Sedirncnt and Erosion Control Measures Sedimsut and erosion control meayuros shall not be placed in wetlands or waters to the maximum extent practicable. If placement of sediment and erosion control devices in wetlands and waters is unavoidable, they shall be removed and the natural grade restored within two (2) months of the date that the Division of Land Resources has released the project. 5. Protective Fencing The outside buffer, wetland or water boundary and along the construction corridor within these boundaries approved under this autltoriwinn shall be ,:learn marked with omngr warning fencing (ur similar high visibility nurterial) for the areas altar have bem approved to infringe within the buffer, wetland or ► ater prior to any land disturbing activities to ensure ccmpliarico with 15A NCAC .2B .0233 and GC: 3627, 6, Diffuse Flow Measures Approved The diffuse flow measures (level spreader designs submitted or, May 31, 2001 and revisions submitted oil .tune 21, 2007) must be implemented and the stoirnwater management facilities shall be constructed Find operational before any permanent building is occupied ar the subject site. 'UL 03,2007 04:59P E. Scott Mitchel 5770875 page 4 Page 3 of 4 June 25, 2007 The snttctural storin water practices as approved by this Office as well as drainage pets=s must bs nnninmined in pGtpctuity. No cliaitbes to the structural stormwater practl;.es shall be rna& without written authorization from the Division of Watcr Quality, Deed Notifications Deed noti.ftcationg or similar mechanisms shall be placed on all retained jurisdictional wetlands, waters and riparian buffers in order to assure compliance for future wetland, water and riparian buffer impact, These mechanisms shall be put in place prior to impacting ;any wetlands, waters and/or buffers approved for impact under this Certification Approval and Authorization Certificate. These documents shall be filed with the Register of Deeds, Wake County, North Carolina. Honeycutt .Estates, LLC shall suhtnit copies of these documents to the Division of Water Quality before any impacts to protected riparian buffers, wetlands, or waters shall ocour. S.ConsiructionStormwawrPermit NCG010000 Upon the approval of an Erosion and Sedimentation Control Plan issued by the Division of Land Resources (DLR) or a. DT R delegated local erosion and sedimentation control program, an NPDES Cyencrai stormwater permit (NCG010000) administered by DWQ is automatically issued to the projw- This General Percent atllows stormwster to be discharged during land disturbing c msUv,.tion activities as stipulated by oondidom in the permit. 1f your project is covered by this permit japplicable to construction projects that disturb one (1) or more acres;, full compliance with permit c n&ions including the sedimentanor control plan, self monitoring, record keeping and reporting requirements are required. A copy of his permit and monitoring report forms may be found at _enr,stcrta.►rr.atsls;r_uFur &cuments htrr.,, 9. C".ertificate of Completion Upon completion Of all work approved within the 401 Water Quality Cerrif Cation or appli::able Buffer Mules, wrtd any sabsequerit modifications, the applicant is required to return the attached certificate: of completion to the 401 Oversight/Express Review P9rtnitting Unit, North Carol na Division of Water Quality, 1650 Mail Service Center, Raleigh, NC:, 27699.1650. 1 D. ZSotifictition of Construction The applicant and/or authorized agent shall contact the DWQ Express Review Progam in writing at the letterhead address within ten (10) days of the commenoeMent of construction. Violations of any condition herein set forth may result in revocation of this Certification and may result in criminal and/or civil penalties. Ae authorization to proceed with your proposed impacts or to conduct impacts to welters as depicted in your application and as authorized by this Certification, shall expire upon expiration of the 404 or CAMA Permit. if you do not accept any of the conditions of this Certification (associated with the approved wetland or stream impacts), you may ask for an adjudicatoiy hearing. You must act within 60 days of the date that you receive this letter. To ask for a hearing, send a written petition, which conforms to Chapter 150B of the North Carolina Gereral Statutes to the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, N,C, 27699-6714. This certification and its conditions are final and binding unless you ask. for a hearing, Any disputes over detenninations regarding this Authorization Certificate (associated with the approved buffer impacts) shall be referred in writing to the Director fur a decision, The Dim tor's decision is subject to review as provided in Articles 3 and 4 of G.S. 150$. JUL 03,2007 05:OOP B. Scott Mitchel 5770875 page 5 Honeycutt F—lutes, L' LC Page 4 of 4 June 25, 2007 This letter completes the review of the Division of water (duality under Section 401 of the Clean Water Act and the Neuse: riparian buffer protection Yule as described within I5A NCAC 2B .0233, If you have any questions, please telephone Lia Myatt or Cynthia Van Der Wiele at 919-733-1786. Sincerely, Coleen H. Sullins, Director NC Division of Water Quality C]431, vdwllcm Enclosures: rC 362' Certificate of Completion CC USACE Raleigh Regulatory Field Office Mike Noran, DWQ Raleigh Regional Coffee DLR Raleigh Regional Office. Filc Copy Central Files Scott Mitchell, Mitchell Environmental, P.A., P.C. Box 341, Fuguay-Varina, l`'C 27526 STATE OF NORTH CAROLINA DEPARTMENT OF TRANSPORTATION MICHAEL F. EASLEY GOVERNOR COUNTY SUBJECT: Alan R. Keith, P.E. Diehl & Phillips, P.A. 219 East Chatham Street Cary, North Carolina 27511 Dear Mr. Keith: September 17, 2007 Wake Construction Plan Review — Rose Hall Subdivision — Phase 2 LYNDO TIPPETT SECRETARY This office has completed its review and hereby approves the subject plans received at this office July 23, 2007 for compliance with current Department of Transportation minimum subdivision construction standards. It is the responsibility of the owner/developer to provide verification certifying that the completed subgrade and base course meet NCDOT requirements. This certification shall be conducted by a professional engineer and shall include the following: proofrol ling of subgrade and base course. (Reference attached construction guidelines) The paving of this roadway shall be in accordance with the revised NCDOT 2006 Standard Specifications, Sections 610, 1012 and 1020. The Contractor shall follow all procedures of the attached Quality Management System (QMS) for asphalt pavement - Maintenance Version. The Contractor must adhere to all testing requirements and quality control requirements specified. The Contractor shall contact the NCDOT Division 5 QA Supervisor at (919)-562-0018 prior to producing plant mix and make the Supervisor aware that the mix is being produced for a future NCDOT road. Only NCDOT approved mix designs will be acceptable. A quality control plan shall be submitted to the District Engineers' Office prior to asphalt production. Use form QMS- MVl for the Quality Control Plan submittal. Failing mixes and/or densities are subject to penalties including monetary payments or removal and replacement. The North Carolina Department of Transportation does not add roads to its system unless they meet the requirements of the current (January 1, 2000) NCDOT Subdivision Roads Manual. Please be aware that only North Carolina Department of Transportation approved structures are to be constructed on public right of ways. The Department will not be held responsible for damages to sprinkler systems placed within the right of way and reserves the right to remove any system that adversely affects safety or maintenance of the roadway. The Department will not be responsible for the perpetual maintenance of BMPs. Since these requirements are the responsibility of the owner/developer, we ask that you provide them with a copy of this letter. Feel free to contact Mr. Byron Sanders, Jr., Assistant District Engineer, at 919-733-7759 if you have questions or need additional assistance. Sin1� R T. R. Elmore District Engineer THE/BS Cc: Jan Womble, w/plans MAILING ADDRESS: TELEPHONE: 919-733-3213 LOCATION: NC DEPARTMENT OF TRANSPORTATION FAX: 919-715-5778 4009 DISTRICT DRIVE DOH DISTRICTI WEBSITE: WWW.DOH.DOT.STATE.NC.US RALEIGH NC 27607 1575 MAIL SERVICE CENTER RALEIGH NC 27699-1575 Subdivision Construction Guidelines The construction, including all materials used within, Rose Hall Subdivision — Phase 2 roadways shall be in accordance with NCDOT's 2006 Standard Specifications far Roads and Structures and NCDOT's 2006 Roadway Standard Drawings. These manuals may be obtained from the Design Services Branch at the Century Center Complex Building B off of Poole Road. Contact Kim Canady at 250-4124 or go online tow.uw.dolt.dot.state.ne.usfguidelinm. Production and inspection of asphalt plant and roadway operations shall be in accordance with the latest Quality Management System (QMS) for asphalt pavements - Maintenance Version. The Department's Division Quality Assurance Lab Supervisor, .Ian Womble (919-562-0018), shall be advised prior to asphalt production and form QMS- MV I shall be submitted to the District Engineers' Office prior to asphalt production. The latest specifications can be downloaded at ►vwrv.doh dot state nc u5J(Ipetationa/dQ chief eng/eon�gxuc:tionvnit/paveconst/c nisintn htm. All Roadway Technicians supervising asphalt work shall be certified by NCDOT. Guidelines can be viewed at httptll�vww,dob.dot-s%te.ne;.us/Memtionsldp chief englconstructionunit/,.,paveeo!lWdefaultl htm. The Engineer shall be responsible for all construction inspection, field materials sampling and testing, and communication and coordination with NCDOT's District Engineer. The Engineer shall be familiar with NCDOT's standard procedures and practices as set forth in the Department's Construction Manual, Standards and Specifications, Roadway Standard Drawings, and Materials and Tests- Manual. The Engineer shall work under the general guidance and direction of NCDOT's District Engineer. The Engineer shall keep detailed and accurate records of the Contractor's daily operations. The Engineer shall maintain records of all sampling and testing accomplished. The Engineer shall verity that all work is being performed in accordance with the Department's Specifications and guidelines. The Engineer shall provide verification signed and sealed certifying that construction meets NCDOT's requirements. Certifications shall include, but not be limited to the following: Embankment Compactions: Every 5000 cubic yards or fraction placed Subgrade Density: Every 1000 linear feet per travel lane (In Subdivisions proofroll all lanes will also be required) ABC Sampling shall be performed according to NCDOT guidelines for projects exceeding 2500 tons. Stone Base Density: Every 1000 linear feet per 28 foot width (In Subdivisions proofroll all lanes will also be required) Stone Base Thickness Asphalt Density: In Accordance with QMS Specifications, Nuclear density results are not accepted with out control strip results. Asphalt Thickness must be verified by taking cores Asphalt Certifications shall be submitted via form QMS-MV2 All drainage pipes, precast concrete, cast iron fittings, and guardrail must be pre -approved by NCDOT's material and test section prior to shipping to construction site. An engineer or certified technician shall verify that all pipe used was properly marked by NCDOT when the material arrived on construction site. All structural stormwater BMP's and associated access/maintenance easements shall be depicted on a final subdivision plat which is recorded with the county Register of Deeds. The operation and maintenance agreements shall be referenced on the final plat and shall be recorded with the county Register of Deeds upon final plat approval. All structural stormwater BM P's shall be located outside of the NCDOT Right -of -Way. A permanent public drainage easement shall be established outside of the NCDOT Right -of -Way by the designer for access to the BMP's. The NCDOT assumes no responsibility for the operation, maintenance or liability of the structural stormwater BMP's. All drainage pipes, precast concrete, cast iron fittings, and guardrail must be pre -approved by NCDOT's material and test section prior to shipping to construction site. An engineer or certified technician shall verify that all pipe used was properly marked by NCDOT when the material arrived on construction site. The developer shall be responsible for the installation of all required signage in accordance with NCDOT Standards Any plan changes shall first be approved by the District Engineer. .4 DUI'.ING THE COURSE OF THE REVIEW IT WAS NOTED THAT THE SITE MAY HAVE IMPACTED A RIVER BASIN BUFFER ZONE AND / OR MAY RE.OUIRE THE APPLICATION AND ISSUANCE OF PERMITS FOR STORuIWATER MANAGEMENT SYSTEMS. IT IS THE RESPONSIBILITY OF THE DEVELOPER/APPLICANT TO CONFORM TO THE REGULATIONS OF GOVERI�IENTAL AGENCIES WITH REGARD TO MINUMIZING WATER QUALITY IMPACTS Ni ADDITION TO THE DRAINAGE REQUIREMENTS OF THE DIVISION OF HIGHWAYS. THIS REVIEW DOES NOT RiPLY CON-FORivIITY TO LOCAL OR OTHER STATE GOVERNt t T REGULATIONS NOR CONSTITUTE AN APPROVAL OF SUCH. All open end cross pipes, in non CAMA counties, will be buried 20% of their diameter 1 to a maximum of one foot as the bed conditions allow. ALL ROADiIAY DITCHES MUST BE STABLE BEFORE' ACCEPTANCE UPON THE ST2.TE SYSTEM FOR NLAINTENANCE. ,lNp f4 Se. u 101.04 HE.ADWALLS ARE USED ON PIPES � 36.' IN DIAh1ETERUSUALLY ;� ON BOTH ENDS BUT ALWAYS ON THE INLET. FLARED END SECTIONS ARE USED ON SWkLLER PIPE. STORMWATER BMP'S AND ASSOCIATED ALL STRUCTURAL L BE DEPICTED ON A FINAL. ACCESS�NT�ANCE EASEMENTS) SHAL REGISTER OF SUBDIVISION PLAT WHICH IS RECORDS AN E AGREEMEITH THE NT SQL BE DEEDS. THE OPERA � MAINT PLAT ANDSHALLBE RECORDED WITH THE REFERENCED ON T COUNTY "GISTER OF DEEDS UPON FINAL PLAT APPROVAL' ALL STRUCTURAL STORMWATER BMP'LOCATED D OUTSIDE OF THE NCDOT RIGHT _O.QQ_ iAY. A PERMANENT E EASEMENT' SHALL BE ESTABLISHED OUTSIDE OF THE NCDOT DRAINAGE RIGHT-OF-WAY BY THE DESIGNER FOR ACCESS TO NCDOT ASSL]MES NO RESPONSIBILITY Og�IWA'I`ER BiV LIABILITY OF THE STRUCTURA STATE OF NORTH CAROLINA DEPARTMENT OF TRANSPORTATION MICHAEL F. EASLEY GOVERNOR October 9, 2008 COUNTY: Wake SUBJECT: Rose Hall Subdivision — Phase 2 Alan R. Keith, PE Diehl & Phillips, PA 219 East Chatham St. Cary, North Carolina 27511 Dear Mr. Keith: LYNDO TIPPETT SECRETARY This is to advise that Cadenza Lane in Rose Hall Subdivision — Phase 2 as shown on the construction plans received on July 23, 2007 and approved on September 17, 2007 have been constructed to meet the minimum construction standards of the Division of Highways. These streets may be added to the State Maintained System when a sufficient number of homes are constructed thereon and the roadway is found to be in an acceptable state of maintenance when petitioned for addition. Sincerely, T. R. Elmore District Engineer THE/BS cc: Lynn Patrie, Wake County MAILING ADDRESS: TELEPHONE: 919-733-3213 LOCATION: NC DEPARTMENT OF TRANSPORTATION FAX: 919-715-5778 4009 DISTRICT DRIVE DOH DISTRICTI RALEIGH NC 27607 1575 MAIL SERVICE CENTER WEBSITE. WWW.DOH.DOT.STATE.NC.US RALEIGH NC 27699-1575 t • Y 6D \ \ CA ENZA L41VE STA. 25 + 00 TO END HORIZONTAL SCALE: 1' VERTICAL.; ' = 40" I �� _SCALE. 1 = 4' C~• C" II C� � � � c` cam' � � • l� �. 28+00 29+00 30+00 31 +OC i r1,J2-A [�ygNO RAC) A Lo L, AAUA x /01 S l ToP w�.m - -79 -- ' _ ' = a►r-U ��� (j. �91j G. Ocd � ' ��.�e car [AF --,LL A.AJGA -7 -715 hol 0- df i Ad, a n tj (1 �.r�rj a, a�6� = EJr 5ri/v6 3f-8,? ;o SLDP(T R 00 rG-oRf, iZ.-Q 4 rji07 rLL,% -Cq&rC OL. Lr=AJf.t=K = ` 0 /lam 0.0�L .U.-.ou-r = 3 `t. o- _ �)" (qL") o - 7,38to -- -- - i y G�wj `- 1-� I) it OF (}ENU i loo LCJATLonJ ► - - 5 �./z c�- --G�tu's J cr�G --- --- - - -- 6.0H 9 o x C. 01-7= I, t 3 _ �r S , Sf �N�, I►�- - -lb t- I � __,A Rulty' la." r.5--t1w6 LLJAIEA__ VA_ Ac.,,�--.r_C._._-'LWTL4J Ar UPr An IL = _ 3 -L'7v I, 7, l~Ar eta= i INLET CONTROL : CORRUGATED METAL PIPE @ HEADWALL FLOW RATE,CFS 202.00 PIPE DIA., INCHES 72.00 HEADWATER DEPTH, FT. : 6.00 HW/D 1.00 Cadenza Lane 72-inch Q-100 OUTLET CONTROL PROFILE TYPE = M2 (DRAWDOWN) ENTRANCE LOSS COEFFICIENT 0.50 FLOW RATE, CFS 202.00 PIPE DIAMETER, INCHES 72.00 MANNING'S 'N' 0.0220 PIPE SLOPE, FT./FT. 0.0065 PIPE LENGTH, FT. 90.00 TAILWATER DEPTH, FT. 4.78 HEADWATER DEPTH, FEET : 6.43 HW/D 1.07 OUTLET VELOCITY, FPS 8.36 Cadenza Lane 72-inch Q-100 v EA „, r '���► �(JaT C4LCU Ar-IIY1VI _AIPJ Q a u 7� `' C ��.�u� roc r�-t A 5 rA6 /s _ �L r�Lcl�,tavuM cr/I r t1 Aw�u,� �crogr,J�c,� �� - - 1NI-C-T f,:4-, SZlLcf6 4- AuKO /wxt N�ttJCo R 7 C ALWL,91Ccaw a ffll _TAILL-OA —ff�._ yid, l N'O 1�+1.1 g `� G�fp - - +4i su�UeY.�a Tit IIH 7�L &-)ITtN146_41J W F4-Lf- - - Go.ys� ic.L) c ;'-3.ltr 4tZ -r ec co, _ 4 Cc - ?, VN - - J�- - Co - nos? 2Uc 6 -1 (mil do ✓ac t ram' At= t4r , S L rrsL)ASaA CdJ1J5r%2fu� 1/ ATt� - S L))LO C /,q-r - L)P S (`/Lk/ Nt <-rl U�1 ll d N--f - O/L - - - DIEHL & PHILLIPS, P.A. CONSULTING ENGINEERS 1500 Piney Plains Rd., Suite 200 Cary, North Carolina 27518 Telephone (919) 467-9972 — Fax (919) 467-5327 July 21, 2020 District Engineer NCDOT 4009 District Drive Raleigh, NC 27607 Re: 84-inch Corrugated Aluminum Pipe, Cadenza Lane Rose Hall Subdivision Phase 2, Wake County Dear Madam / Messer: WILLIAM C. DIEHL, P.E. JOHN F. PHILLIPS, P.E. ALAN R. KEITH, P.E. Diehl & Phillips, P.A. designed the subdivision streets for Rose Hall Subdivision Phase 2 in 2007. Cadenza Lane in Phase 2 included an 84-inch aluminum culvert crossing of a branch that carried Neuse Riparian Buffers. The 84-inch culvert crossing was the subject of a flood study as required by Wake County, and Neuse Riparian Buffer impacts (letter attached). All required environmental permits were obtained and followed during construction to the best of our knowledge. NCDOT reviewed and approved the plans for construction of Phase 2 streets (letter attached). The project was constructed and a "Built to Standards" letter was issued by the NCDOT District Office on October 9, 2008 (copy attached). A 72-inch culvert was required hydraulically for the Cadenza Lane crossing in Phase 2. An 84- inch culvert was approved so that the culvert could be buried 12 inches as required by the environmental permitting. The inverts of the 84-inch culvert were designed 12 inches below the existing channel to achieve the 12-inch burial requirement. The rip rap dissipator on the downstream end of the culvert was set 12 above the culvert invert out with the intent of creating a dam to promote filling the bottom of the culvert with sediment. The 84-inch culvert installation was surveyed following construction to verify that the elevations matched the design. The survey confirmed that the culvert was set such that the flood elevations matched the approved flood study and environmental requirement (see attached certification). Thus, the 84-inch culvert was constructed as designed and approved by regulatory agencies. Our firm visited the culvert installation in June, 2020 at the request of the Rose Hall Homeowners Association. We were given a copy of a October 16, 2015 memo from Bridge Maintenance to your office regarding items required for correction for street maintenance acceptance (copy attached). Enclosed with this letter are plans and details to address the items listed in the Bridge Maintenance Memo. The following are proposed: 1. The culvert is set at the proper elevation per the certification. A concrete baffle wall and larger rip rap are proposed to create the 12-inch bury (sedimentation) of the culvert as originally intended. The void area under ends of the culvert would be grouted. 2. The slopes at the inlet end would be improved by installing rip rap lined channels on either side to replace the original channels. Filter fabric would be installed under the channels and the new rip rap at the culvert entrance. 3. The slopes on either side of the outlet end of the culvert would be improved by installing rip rap lined channels on either side of the culvert. The dissipator for culvert would be improved by adding Class 1 rip rap and filter fabric. The rip rap would be placed against the baffle wall for added stability. 4. The gouges in the top of the pipe were observed. No water, seepage, or soil was evident from any of the damaged sites. Further, it appears that the gouges were repaired during construction by adding structural elements on the outside of the culvert to seal the gouges. Since the structure appears to be sound, we do not propose corrective action. We request that you review the plan and notify us if the N.C. Department of Transportation will allow the proposed measures to satisfy the deficiencies noted. Contact our office if you require anything further. Sincerely, Diehl & Phillips, P.A. efA�4 -�4 Alan R. Keith, P.E. enclosures Cc: Kevin Gordan