Loading...
HomeMy WebLinkAbout20040131 Ver 1_Complete File_200402020?6\N V ATFRQG Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources ?- Alan W. Klimek, P.E. Director > Coleen H. Sullins, Deputy Director p ^? Division of Water Quality February 26, 2004 Cleveland County DWQ Project No. 040131 SR 1619 (Bridge No. 187) APPROVAL of 401 Water Quality Certification with Additional Conditions Mr. M. L. Holder, P.E. Division Engineer N C Department of Transportation Post Office Box 47 Shelby, North Carolina 28151 WETLANDS 140'9 GROUP MAR 9 U04 f0!14 Dear Mr. Holder: You have our approval, in accordance with the attached conditions and those listed below, to impact 40 linear feet of stream bank around bridge piers adjacent to Knob Creek (40 linear feet of riprap) and install a 40 foot long, temporary riprap work bench, in order to replace Bridge No. 187 on NCSR 1619 (Sand Pit Road) in Cleveland County. The project must be constructed in accordance with the application dated January 23, 2004 (received February 2, 2004), including the environmental commitments made in the application letter. After reviewing your application, we have decided that this fill is covered by General Water Quality Certification Nos. 3404 and 3366, corresponding to the U.S. Army Corps of 17.ngineers Nationwide Permit Numbers 14 and 33. In addition, you must acquire any other federal, state or local permits before you proceed with your project including (but not limited to) Sediment and Erosion Control, Non-Discharge and Water Supply Watershed regulations. This approval will expire with the accompanying 404 Permit unless otherwise specified in the Water Quality Certification. This approval is valid solely for the purpose and design described in your application (unless modified below). Should your project change, you must notify the DWQ in writing and submit a new application. If the property is sold, the new owner must be given a copy of this Certification and approval letter, and is thereby responsible for complying with all the conditions. If total wetland fills for this project (now or in the future) exceed one acre, or of total impacts to streams (now or in the future) exceed 150 linear feet, compensatory mitigation may be required as described in 15A NCAC 2H .0506 (h) (6) and (7). For this approval to be valid, you must follow the conditions listed in the attached certification and any additional conditions listed below. 1. Erosion and sediment control practices must be in full compliance with all specifications governing the proper design, installation and operation and maintenance of such Best Management Practices in order to protect surface waters standards: a. The erosion and sediment control measures for the project must be designed, installed, operated, and maintained in accordance with the most recent version of the North Carolina Sediment and Erosion Control Planning and Design Manual. b. The design, installation, operation, and maintenance of the sediment and erosion control treasures must be such that they equal, or exceed; the requirements specified in the most recent version of the North Carolina Sediment and Erosion Control Manual. The devices shall be maintained on all construction sites, borrow sites, and waste pile. (spoil) projects, including contractor-owned or leased borrow pits associated with the project. c. For borrow pit sites, the erosion and sediment control measures must be designed, installed, operated, and maintained in accordance with the most recent version of the North Carolina Surface Mining Manual. d. Any reclamation measures and implementation must comply with the reclamation in accordance with the requirements of the Sedimentation Pollution Control Act. 919 N. Main St., Mooresville, NC 28115 Telephone: 704/663-1699 Fax: 704/663-6040 Mr. M. L. Holder, P.E. February 26, 2004 Page Two 2. No waste, spoil, solids, or fill of any kind shall occur in wetlands, waters, or riparian areas beyond the footprint of the impacts depicted in the Preconstruction Notice Application. All construction activities, including the design, installation, operation, and maintenance of sediment and erosion control Best Management Practices, shall be performed so that no violations of state water quality standards, statutes, or rules occur. 3. Sediment and erosion control measures shall not be placed in wetlands or waters to the maximum extent practicable. If placement of sediment and erosion control devices in wetlands and waters is unavoidable, they shall be removed and the natural grade restored within six months of the date that the Division of Land Quality has released the project. 4. NCDOT shall comply with any conditions or moratoriums requested by the NC Wildlife Resources Commission. 5. The riprap used for temporary fill must be clean rock and free of fines. All of this material must be removed by the completion of the project. 6. Riparian vegetation must be reestablished within the construction limits of the project by the end of the growing season following completion of construction. 7. Stortnwater should be directed to vegetated buffer areas, grass lined ditches or other means appropriate to the site for the purpose of pre-treating stormwater runoff, and must not be routed directly into streams. Mowing of existing vegetated buffers is strongly discouraged, so that they may be utilized for stormwater sheet flow. 8. Removal of vegetation at the stream crossing and adjacent to streams should be minimized. Native trees and shrubs (e.g. Rhododendron, dog hobble, willows, alders, sycamores, dogwoods, black walnut and red maple) should be planted along the streambank to reestablish the riparian zone and to provide long-term erosion control in the vicinity of the road crossing and along the streams within dedicated rights of way. 9. Riprap placed for bank stabilization should be limited to the streambank below the high water mark, and vegetation should be used for stabilization above the high water elevation. 10. Heavy equipment must be operated from the banks rather than in the stream channel in order to minimize sedimentation and reduce the likelihood of introducing other pollutants into the stream. 11. All mechanized equipment operated near surface waters must be regularly inspected and maintained to prevent contamination of stream waters from fuels, lubricants, hydraulic fluids, or other toxic materials. 12. Excavation of the stream crossings and relocations should be conducted in the dry, if possible. Sandbags, cofferdams, flexible pipe or other diversion structures should be used to minimize excavation in flowing water. 13. If concrete is used during bridge construction (e.g., headwalls, piers), a dry work area should be maintained to prevent direct contact between curing concrete and stream water. Water that inadvertently contacts uncured concrete should not be discharged to surface waters due to the potential for fish kills. 14. Discharging hydroseed mixtures and washing out hydroseeders and other equipment in or adjacent to surface waters is strictly prohibited. 15. The presence of equipment in the channels must be minimized. Under no circumstances must rock, sand or other materials be dredged from the wetted stream channel under authorization of this permit, except in the immediate vicinity of the culverts. Instream dredging has catastrophic effects on aquatic life and disturbance of the natural form of the stream channel will likely cause downstream erosion problems, possible affecting other landowners. 16. All work shall be performed during low flow conditions. 17. Upon completion of the project, the NCDOT shall complete and return the enclosed "Certificate of Completion" form to notify NCDWQ when all work included in the §401 Certification has been completed. The responsible party shall complete the attached form and return it to the 401/Wetlands Unit of the NC Division of Water Quality upon completion of the project. NCDOT is strongly advised to send in photographs upstream and downstream of each structure to document correct installation. If you do not accept any of the conditions of this certification, you may ask for an adjudicatory hearing. You must act within 60 days of the date that you receive this letter. To ask: for a hearing, send a written petition, which conforms to Chapter 1.50B of the North Carolina General Statutes to the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, N.C. 27699-6714. This certification and its conditions are final and binding unless you ask for a hearing. Mr. M. L. Holder, P.E. February 26, 2004 Page Three This letter completes the review of the Division of Water Quality under Section 401 of the Clean Water Act. If you have any questions, please telephone Ms. Cynthia Van Der Wiele at 919.733.5715 or Mr. Mike Parker of the Asheville Regional Office at 828.251.6208. Sincerely, PJ--- lan W. Klimek, P.E. Attachment cc: Wilmington District Corps of Engineers Trish Simon, Division 12, DEO Steve Lund, USACE Asheville Field Office Mooresville Regional Office Wetlands/401 Unit Mike Parker, NCDWQ Asheville Regional Office MEMORANDUM TO: John Dorney Regional Contact: Non-Discharge Branch WO Supervisor: Date: SUBJECT: WETLAND STAFF REPORT AND RECOMMENDATIONS Facility Name NCDOT - Bridge 187 on SR 1619 Project Number 04 0131 Recvd From DOT County CLEVELAND County2 Region Mooresville Received Date 2/2/04 Recvd By Region Project Type replace bridge with bridge Certificates Stream Permit Wetland Wetland Wetland Stream Class Acres Type Type Impact Score Index Prim. Supp. Basin Req. Stream Impacts (ft.) Feet Req. 14 Stream P-17-0 " I 9-50-19 F-C _F- 30,804. F- 80.00 80.00 F_33F_ O Y O N F-F-F-F--F--F-- Mitigation Wetland MitigationType Type Acres Feet Is Wetland Rating Sheet Attached? 0 Y .O N Did you request more info? 0 Y 6 N Have Project Changes/Conditions Been Discussed With Applicant? 0 Y 0 N Is Mitigation required? 0 Y 0 N Recommendation: 0 Issue 0 Issue/fond 0 Deny Provided by Region: Latitude (ddmmss) 353046 Longitude (ddmmss) 813155 cc: Regional Office Central Office Page Number 1 WETLANDS/ 401 GROUP `? FED 0 ? ..2004 ?••°""''• WATER QUALITY SECTION STATE of NORTH CAROLINA DEPARTMENT OF TRANSPORTATION MICHAEL F. EASLEY P.O. Box 25201, RALEIGH, N.C. 27611-5201 LYNDO TIPPETT GOVERNOR SECRETARY P.O. BOX 47,1710 East Marion Street Shelby, N. C. 28151-0047 January 23, 2004 Mr. Steve Lund, NCDOT Projects US Army Corp of Engineers Asheville Regulatory Field Office 151 Patton Avenue, Room 208 040131 Asheville, N. C. 28801-5006 Dear Mr. Lund: The North Carolina Department of Transportation, Division of Highways, request the issuance of a Section 404 Permit, Nationwide Permit #14, Maintenance and #33, Temporary Construction, Access, and Dewatering. COUNTY: Cleveland LOCATION: Bridge #187, SR 1619, north of Belwood STREAM: Knob Creek (Big Knob Creek), Class C Waters (from source to a point 0.3 miles downstream of Adams Creek), Broad River Basin PROJECT DESCRIPTION: The project consists of the replacement of an existing 12'wide x 40' long timber bridge with a 33' wide x 95' long concrete bridge. The increase in bridge length will allow for the removal of the existing timber abutments that are currently constricting stream flow, therefore reestablishing a natural stream section. Riprap will be placed for on the streambanks for 40 linear feet around the bridge piers to provide structure stabilization. The use of riprap will not exceed the quantity necessary to protect the new bridge substructure. A 40-foot long temporary riprap workbench will be utilized to install the north bridge piers. Upon project completion, the temporary workbench will be removed and the stream dimensions restored. I have enclosed a PCN application, a sketch of activities- including preliminary erosion control sketch and location maps relative to the project. Mr. Steve Lund BR#187, SR 1619, Cleveland County Page Two The proposed project is located in Class C waters; therefore, hazardous spill basins are not required. Enclosed is the NCDOT hazardous spill basin checklist for this project. A review of the Natural Heritage information for the threatened species listed for Cleveland County, the dwarf-flowered heartleaf (Hemsiylis nan flora), revealed no known sites in the vicinity of the project area. A survey for the heartleaf species was conducted on January 20, 2004 in the vicinity of the proposed project. It was determined that no heartleaf species was located in the project area; therefore, no impact is anticipated. A review of the available information from the National Register of Historic Places was also conducted. No historic sites will be affected by the project. Your earliest consideration for this request would be greatly appreciated. Should you have any questions, please call me at 704-480-9020. Respectfully yours, M.L. Holder, P.E. Division Engineer Twelfth Division BY: Trish Simon Division 12 Environmental Supervisor Enclosures cc: Mr. Michael L. Holder, P.E., Division Engineer Mr. Dan Holderman, P.E., Division Bridge Engineer Mr. Jason Willis, Roadside Environmental Field Operations Mr. Mike Parker, DENR, DWQ, Asheville Regional Office Mr. John Dorney, DENR, DWQ, 401/Wetlands Unit Mr. Ron Linville, N.C. Wildlife Resources Commission Mr. Brian Cole, U. S. Fish & Wildlife Service File Office Use Only: Form Version October 2001 USACE Action ID No. DWQ No0.40131 If any particular item is not applicable to this project, please enter "Not Applicable" or "N/A" rather than leaving the space blank. I. Processing 1. Check all of the approval(s) requested for this project: ® Section 404 Permit ? Section 10 Permit ®401 Water Quality Certification ? Riparian or Watershed Buffer Rules 2. Nationwide, Regional or General Permit Number(s) Requested: Nationwide Permit #14, 933 3. If this notification is solely a courtesy copy because written approval for the 401 Certification is not required, check here: ? 4. If payment into the North Carolina Wetlands Restoration Program (NCWRP) is proposed for mitigation of impacts (see section VIII - Mitigation), check here: ? EL Applicant Information 1. Owner/Applicant Information Name: Mike Holder NCDOT Mailing Address: P.O. Box 47 Shelby, NC 28151 Telephone Number: 704-480-9020 Fax Number: 704-480-5401 E-mail Address: 2. Agent Information (A signed and dated copy of the Agent Authorization letter must be attached if the Agent has signatory authority for the owner/applicant.) Name: _ Trish Simon Company Affiliation: NCDOT Mailing Address: P.O. Box 47 Shelby, NC 28151 Telephone Number: 704-480-9044 Fax Number: 704-480-5401 E-mail Address: tsimon@dot.state. nc us Page I of 7 III. Project Information Attach a vicinity map clearly showing the location of the property with respect to local landmarks such as towns, rivers, and roads. Also provide a detailed site plan showing property boundaries and development plans in relation to surrounding properties. Both the vicinity map and site plan must include a scale and north arrow. The specific footprints of all buildings, impervious surfaces, or other facilities must be included. If possible, the maps and plans should include the appropriate USGS Topographic Quad Map and NRCS Soil Survey with the property boundaries outlined. Plan drawings, or other maps may be included at the applicant's discretion, so long as the property is clearly defined. For administrative and distribution purposes, the USACE requires information to be submitted on sheets no larger than 11 by 17-inch format; however, DWQ may accept paperwork of any size. DWQ prefers full-size construction drawings rather than a sequential sheet version of the full-size plans. If full-size plans are reduced to a small scale such that the final version is illegible, the applicant will be informed that the project has been placed on hold until decipherable maps are provided. 1. Name of project: Replacement of Bridge #187 Sand Pit Road. SR 1619. Cleveland County 2. T.I.P. Project Number or State Project Number (NCDOT Only): 37495 3. Property Identification Number (Tax PIN): N/A 4. Location County: Cleveland Nearest Town: Belwood Subdivision name (include phase/lot number): NA Directions to site (include road numbers, landmarks, etc.): Hwy 18 north from Shelby. turn left onto SR 1619 Sandpit Rd project site first bridge (#187) 5. Site coordinates, if available (UTM or Lat/L.ong): 35° 30'46" N. 81' 31' 55" W (Note - If project is linear, such as a road or utility line, attach a sheet that separately lists the coordinates for each crossing of a distinct waterbody.) 6. Describe the existing land use or condition of the site at the time of this application: NCDOT right-of-way 7. Property size (acres): 0.2 acres 8. Nearest body of water (stream/river/sound/ocean/lake): Knob Creek 9. River Basin: Broad (Note - this must be one of North Carolina's seventeen designated major river basins. The River Basin map is available at http://h2o.enr.state.nc.us/admin/maps/.) 10. Describe the purpose of the proposed work: The project consists of replacing a structurally deficient and functionally obsolete 12' wide x 40' long timber bridge with a 33' wide x 95' long concrete bridge. Page 2 of 7 11. List the type of equipment to be used to construct the project: Drilling rig, crane, and trackhoe will be used for construction. 12. Describe the land use in the vicinity of this project: Cultivated croplands, cow feeding lot, and woodlands. IV. Prior Project History If jurisdictional determinations and/or permits have been requested and/or obtained for this project (including all prior phases of the same subdivision) in the past, please explain. Include the USACE Action ID Number, DWQ Project Number, application date, and date permits and certifications were issued or withdrawn. Provide photocopies of previously issued permits, certifications or other useful information. Describe previously approved wetland, stream and buffer impacts, along with associated mitigation (where applicable). If this is a NCDOT project, list and describe permits issued for prior segments of the same T.I.P. project, along with construction schedules. V. Future Project Plans Are any future permit requests anticipated for this project? If so, describe the anticipated work, and provide justification for the exclusion of this work from the current application: No future permit requests anticipated. VL Proposed Impacts to Waters of the United States/Waters of the State It is the applicant's (or agent's) responsibility to determine, delineate and map all impacts to wetlands, open water, and stream channels associated with the project. The applicant must also provide justification for these impacts in Section VII below. All proposed impacts, permanent and temporary, must be listed herein, and must be clearly identifiable on an accompanying site plan. All wetlands and waters, and all streams (intermittent and perennial) must be shown on a delineation map, whether or not impacts are proposed to these systems. Wetland and stream evaluation and delineation forms should be included as appropriate. Photographs may be included at the applicant's discretion. If this proposed impact is strictly for wetland or stream mitigation, list and describe the impact in Section VIII below. If additional space is needed for listing or description, please attach a separate sheet. 1. Wetland Impacts: NONE Wetland Impact Site Number indicate on ma Type of Impact* Area of Impact (acres) Located within 100-year Floodplain** es/no Distance to Nearest Stream linear feet Type of Wetland*** * List each impact separately and identify temporary impa°ts. Impacts include, but are not limited to: mechanized clearing, grading, fill, excavation, flooding, ditching/drainage, etc. For dams, separately list impacts due to both stnwc and flooding. ** 100-Year floodplams are identified through the Federal Emergency Management Agency's (FEMA) Flood Insurance Rate Maps (FIRM), or FEMA-approved local floodplain maps. Maps are available through the FEMA Map Service Center at 1-800-358-9616, or online at httn://www. fema. gov. *** List a wetland type that best describes wetland to be impacted (e.g., freshwater/saltwater marsh, forested wetland, beaver pond, Carolina Bay, bog, etc.) Page 3 of 7 List the total acreage (estimated) of existing wetlands on the property: 0 2. Stream Impacts, including all intermittent and perennial streams Stream Impact Site Length of Impact Average Width Perennial or Number Type of Impact* sm ear feet) ** Stream Name** of Stream Intermittent? (indicate on Before Impact (please specify) ma Riprap on I streambank for 40 feet Knob Creek 25 feet Perennial structure stabilization 1 Temporary bench 40 feet " List each impact separately and identify temporary impacts. Impacts include, but are not limited to: culverts and associated rip-rap, dams (separately list impacts due to both structure and flooding), relocation (include linear feet before and after, and net losstgain), stabilization activities (cement wall, rip-rap, crib wall, gabions, etc.), excavation, ditching/straightening, etc. If stream relocation is proposed, plans and profiles showing the linear footprint for both the original and relocated streams must be included. Stream names can be found on USGS topographic maps. If a stream has no name, list as UT (unnamed tributary) to the nearest downstream named stream into which it flows. USGS maps are available through the USGS at 1-800-358-9616, or online at www.usgs.eov. Several internet sites also allow direct download and printing of USGS maps (e.g., www.topozone.com, www.mapquest.com, etc.). Cumulative impacts (linear distance in feet) to all streams on site: 40' permanent streambank impacts and 40' temporary stream impacts. Open Water Impacts, including Lakes, Ponds, Estuaries, Sounds, Atlantic Ocean and any other Water of the U. S. NO OPEN WATER MACTS Open Water Impact Area of Name of Wateibody Type of Waterbody Site Number Type of Impact* Impact (if applicable) (lake, pond' estuary, sound' indicate on ma acres bay, ocean, etc. " List each impact separately and identify temporary impacts. Impacts include, but are not limited to: fill, excavation, dredging, flooding, drainage, bulkheads, etc. 4. Pond Creation NO POND CREATION If construction of a pond is proposed, associated wetland and stream impacts should be included above in the wetland and stream impact sections. Also, the proposed pond should be described here and illustrated on any maps included with this application. Pond to be created in (check all that apply): ? uplands ? stream ? wetlands Describe the method of construction (e.g., dam/embankment, excavation, installation of draw-down valve or spillway, etc.): Proposed use or purpose of pond (e.g., livestock watering, irrigation, aesthetic, trout pond, local stormwater requirement, etc.): Size of watershed draining to pond: Expected pond surface area: VII. Impact Justification (Avoidance and Minimization) Specifically describe measures taken to avoid the proposed impacts. It may be useful to provide information related to site constraints such as topography, building ordinances, accessibility, and financial viability of the project. The applicant may attach drawings of alternative, lower-impact site layouts, and explain why these design options were not feasible. Also discuss how impacts Page 4 of 7 were minimized once the desired site plan was developed. If applicable, discuss construction techniques to be followed during construction to reduce impacts. The deficient bridge is being replaced with another bridge. therefore. there is no net loss of linear stream footage The proposed bridge length will allow removal of the existing timber abutments that are currently constricting stream flow therefore reestablishing a natural stream section. The use of riprap will be limited to the quantity necessary to protect the new bridge substructure VIII. Mitigation DWQ - In accordance with 15A NCAC 2H .0500, mitigation may be required by the NC Division of Water Quality for projects involving greater than or equal to one acre of impacts to freshwater wetlands or greater than or equal to 150 linear feet of total impacts to perennial streams. USACE - In accordance with the Final Notice of Issuance and Modification of Nationwide Permits, published in the Federal Register on March 9, 2000, mitigation will be required when necessary to ensure that adverse effects to the aquatic environment are minimal. Factors including size and type of proposed impact and function and relative value of the impacted aquatic resource will be considered in determining acceptability of appropriate and practicable mitigation as proposed. Examples of mitigation that may be appropriate and practicable include, but are not limited to: reducing the size of the project; establishing and maintaining wetland and/or upland vegetated buffers to protect open waters such as streams; and replacing losses of aquatic resource functions and values by creating, restoring, enhancing, or preserving similar functions and values, preferable in the same watershed. If mitigation is required for this project, a copy of the mitigation plan must be attached in order for USACE or DWQ to consider the application complete for processing. Any application lacking a required mitigation plan or NCWRP concurrence shall be placed on hold as incomplete. An applicant may also choose to review the current guidelines for stream restoration in DWQ's Draft Technical Guide for Stream Work in North Carolina, available at http://h2o.enr.state.nc.us/ncwetlands/strmizide.html. Provide a brief description of the proposed mitigation plan. The description should provide as much information as possible, including, but not limited to: site location (attach directions and/or map, if offsite), affected stream and river basin, type and amount (acreage/linear feet) of mitigation proposed (restoration, enhancement, creation, or preservation), a plan view, preservation mechanism (e.g., deed restrictions, conservation easement, etc.), and a description of the current site conditions and proposed method of construction. Please attach a separate sheet if more space is needed. IMPACTS < 150 FEET, MITIGATION NOT ANTICIPATED 2. Mitigation may also be made by payment into the North Carolina Wetlands Restoration Program (NCWRP) with the NCWRP's written agreement. Check the box indicating that you would like to pay into the NCWRP. Please note that payment into the NCWRP must be reviewed and approved before it can be used to satisfy mitigation requirements. Applicants will be notified early in the review process by the 401/Wetlands Unit if payment into the NCWRP is available as an option. For additional information regarding the application process for the NCWRP, check the NCWRP website at http://h2o.cnr.state.nc.us/wrp/index.htm. If use of the NCWRP is proposed, please check the appropriate box on page three and provide the following information: Page 5 of 7 Amount of stream mitigation requested (linear feet): Amount of buffer mitigation requested (square feet): Amount of Riparian wetland mitigation requested (acres): Amount of Non-riparian wetland mitigation requested (acres): Amount of Coastal wetland mitigation requested (acres): IX. Environmental Documentation (DWQ Only) Does the project involve an expenditure of public funds or the use of public (federal/stateAocal) land? Yes ® No ? If yes, does the project require preparation of an environmental document pursuant to the requirements of the National or North Carolina Environmental Policy Act (NEPA/SEPA)? Note: If you are not sure whether a NEPA/SEPA document is required, call the SEPA coordinator at (919) 733-5083 to review current thresholds for environmental documentation. Yes ? No If yes, has the document review been finalized by the State Clearinghouse? If so, please attach a copy of the NEPA or SEPA final approval letter. Yes ? No ? X. Proposed Impacts on Riparian and Watershed Buffers (DWQ Only) It is the applicant's (or agent's) responsibility to determine, delineate and map all impacts to required state and local buffers associated with the project. The applicant must also provide justification for these impacts in Section VII above. All proposed impacts must be listed herein, and must be clearly identifiable on the accompanying site plan. All buffers must be shown on a map, whether or not impacts are proposed to the buffers. Correspondence from the DWQ Regional Office may be included as appropriate. Photographs may also be included at the applicant's discretion. Will the project impact protected riparian buffers identified within 15A NCAC 2B .0233 (Neese), 15A NCAC 213 .0259 (Tar-Pamlico), 15A NCAC 2B .0250 (Randleman Rules and Water Supply Buffer Requirements), or other (please identify )? Yes ? No ® If you answered "yes", provide the following information: Identify the square feet and acreage of impact to each zone of the riparian buffers. If buffer mitigation is required calculate the required amount of mitigation by applying the buffer multipliers. * Zone Impact (square feet Multiplier Required Mitigation 1 3 2 1.5 Total ' Zone 1 extends out 30 feet perpendicular from near bank of channel; Zone 2 extends an additional 20 feet from the edge of Zone 1. Page 6 of 7 If buffer mitigation is required, please discuss what type of mitigation is proposed (i.e., Donation of Property, Conservation Easement, Riparian Buffer Restoration / Enhancement, Preservation or Payment into the Riparian Buffer Restoration Fund). Please attach all appropriate information as identified within 15A NCAC 2B .0242 or.0260. XL Stormwater (DWQ Only) Describe impervious acreage (both existing and proposed) versus total acreage on the site. Discuss stormwater controls proposed in order to protect surface waters and wetlands downstream from the property. Additional impervious surface of 0.019 acres is proposed (increase in bridge widthl. Stormwater will be directed off the proposed bridge deck via funnel drains into riprap lined ditchlines XII. Sewage Disposal (DWQ Only) Clearly detail the ultimate treatment methods and disposition (non-discharge or discharge) of wastewater generated from the proposed project, or available capacity of the subject facility. N/A XM. Violations (DWQ Only) Is this site in violation of DWQ Wetland Rules (15A NCAC 2H.0500) or any Buffer Rules? Yes ? No Is this an after-the-fact permit application? Yes ? No XIV. Other Circumstances (Optional): It is the applicant's responsibility to submit the application sufficiently in advance of desired construction dates to allow processing time for these permits. However, an applicant may choose to list constraints associated with construction or sequencing that may impose limits on work schedules (e.g., draw-down schedules for lakes, dates associated with Endangered and Threatened Species, accessibility problems, or other issues outside of the applicant's control). Applicant/Agent's Signature Date (Agent's signature is valid only if an authorization letter from the applicant is provided.) Page 7 of 7 (Photo #1) One lane bridge (#187) over Knob Creek looking downstream. (Photo #3) Knob Creek looking upstream from under bridge (#187). 3 4 5 SOUTH g = sY'ss' MOUNTAIN WILDLIFE - o B U R K E C O U N T Y 0 T AREA MANAIGEME / C ATAWBA CO. N ?.. ? EM le ,? K " WAM y •?? 1 J OA./? ? ?,? M11?A10 ?L?? =° 394 GAP -\ , --l KNO D .O COVMfOioN rAre I M KNOB ILA n iLll UIQ ~ iw ' CAR Co- KMOK ua 170 lilt y 393 ' CAMP 138 ? un u 1l77 , ? KNOK • OLD Se1Q/ l sss J I .7 70 • 17 7 , rl i Y KN« E2 Ila .?ligNfi J 4 'Aoo t NO M7564M M I 11.l4 J12! 1 ' 'Y' .e ray` - j% 10 DES 1f.? LOQI 77 7 w -10 1 ( 0 16 9 I 4 y ` 0 0 C)II r Nr.+ 10 I °? Z Norl.e ?? T? s•?o' To sou rN V .OuNrA ,NsrltL7t 77 ? r: J L r f q Z n '.? eflwoOD f ror 617 EeMs v ,... Z ,p` 0 1 1 e •s Cw 10 r - LIM c is hn °n B?oncA L Gje? I rl \ LAWNDALE d r • . POP .60 ALL TON POP elc 111, 1e7 1 MILK llE 35°7s' I ror 7e ^ e Ie7 res L n7 rAs I\ rA5 - L? _ e C MAtCI. C? lder. Crosvood6 Compcoll V ?y r ??' M.rrall / O I6 r vc, U OTT -a ? ?C?V L'L.?4v ? G auc,TC? .r I J L,e V6 1Co1 `i ?? ?C?1cc Yti??'=rvi ?F r3/2. 'd/t37 - - \/m ES cry Q 726 e0110 / i POP, -as IATI'IMOKE MS D- 11o4- n/ 1 ( ?-11 , ! AMT ..... ` •, '•\ , s .+ -'1 _ '-na"A.. ???l- j ? ? t-_?, \,° ? ,.?? •' ? O M ?/ , X49 ,I'' \?? ? ?• ) ?. ` Bridge (#18? o f replacement, Sand Pit Rd. SR 1619 `'- . l / . Name: CASAR Location: 035° 30'43.53" N 081 ° 31'36.19, W Date: 1/20/2004 Caption: Bridge (#187) replacement over Knob Creek, Class C Water, in Scale: 1 inch equals 2000 feet the Broad River Basin t2 CO ,?ge2 ? ! 1 ? lit '36LQ Carpenter , p 1552 15926 Knob 4 Little i' Knob 11 ?\ C: ° • ? ii / 106? p , \\ Peoples • ;'1959 Chi 11 / // 'rata CIce ZONE A ?- 260 N\ - 0 B C v,.R E K ?.• ??? ?j 16D3 j ?? 16Cc I'==- ?i If 11 ??' Cem.•;?. j; i• .n u ?I %.arpenter? Grove' IIf I Ch . 1? I /OB5 \ • c • _ 1 c ??_? ?d055 \ , ?? •Jt 1, 1 \ ZONE I, ZONE X 4 oc /L= 9ZONE X _ . t6t ?/ , •;i? ?? Knob ? - - ? -_ ? ^Creek,l? BONE A ?W I? ZONE A • II ° Town of Belwood AREA NOT INCLUDED' JOINS PANEL 0100 G le Ve (a^ „f Ccu o4-\/ 1 1 ? cuc.-rx?r??j J NI T-0 ? g?' r2?,,,uvET7 \t s N lI ? _ 2ipe-A,? c??sn???, se ???g l??2o??vsc? 4+00 i P2oPv? 33 ,w ?- 4 ?L ash cvvc2LT75 r3???4tiE PYLoAoS?+? C?..? SS [Z lZi (Pv2?l A Tc--)'PM42t1 ILOPOtA;r?y? Wo2k, 9COC14 i r/uoaaf, PlC,L )IZit-Lo e-) OPG44T14)j O&J PLAIJ 2! Pit,+P cwr)nvii 77-"o5C-Z $u.Kp4-C. f 35 ? G o ? 7v 3 E' iZEy-+?vtJ? _j a? f ?,/Ec.7' 3 X495 'Scrtc.E. ? i = Sa 4x-)- oT" GLEV?? CaZLvT'?? Ila ?O r i wa2?C. K G?C.I? 40' L I Le 'S1Tc-c,Gt?S ??15?? (off- 5 r Lr r3?4zi, W? SCvfAc- -?ucuj-j 5 Cc>J -?,T ? Ll G"R wog ac* I 56LT rEVCE r ? J C fZv 510J 401-MW G• 51( Te- 4 ?u?a??. ? IZ.rh,,a / ? 20??:a" '? x745 S GC.E?C[.r}rv? ?vu,?c.j 0?'+1? S2 / (o! 9 ?iLc7fC'c.7' gA). -'o 1e7 5CAL,E. / :gam' i v NCDOT HAZARDOUS SPILL BASIN CHECKLIST Division: / ?-- County: cc.ELifFc, 4 Project ID: 37+'7a- River Basin:??,4,? Bridge No: /87 Stream: 1[ Ayv? C- Route : 5, -o' Water Quality Criteria: Yes No Stream Crossing Blue Line On USGS f:/' r ORW r r? WSI r r? WS II1III OR IV, Crossing Within 0.5mi of W.S. Critical Area r r? Roadway Criteria: Route Designation- Yes No Arterial Urban r r? Arterial Rural r r/ Additional Site Information: Yes No Is a Hazardous Spill Basin Required? r r? Criteria Based Upon NCDOT "Best Management Practices for the Protection of Surface Waters" (March, 1997). WETLANDS / 401 G80IJp n .2004 ? .? WATER QuALi. •??.?.• ly SECTION STATE OF NORTH CAROLINA DEPARTMENT OF TRANSPORTATION MICHAEL F. EASLEY LYNDO TIPPETT GOVERNOR SECRETARY 0401 31 MEMO TO: John Dorney, DENR/DWQ/401/Wetlands Unit FROM: Trish Simon, Division 12 Environmental Supervisor O DATE: January 23, 2004 SUBJECT: Pre-Construction Notification/401 Automated Payment Enclosed are seven copies of a pre-construction notification for a NCDOT project in Cleveland County for your review. Project information for the 401 Automated Payment Procedure • Work order number: 150465-55120005-37495-4686-49360 • TIP #: NA • Project Category: $200.00 Fee is Post Office Box 47 Shelby, North Carolina 28 1 5 1-0047 O?O? W AT jSRQG r O '< DWQ Project No.: 04-0161 County: Applicant: ?? aT - ??ciis<?.J /Z Project Name: lL??/fcG?r?? OG Date of Issuance of 401 Water Quality Certification: Certificate of Completion Upon completion of all work approved within the 401 Water Quality Certification or applicable Buffer Rules, and any subsequent modifications, the applicant is required to return this certificate to the 401/Wetlands Unit, North Carolina Division of Water Quality, 1650 Mail Service Center, Raleigh, NC, 27699-1650. This form may be returned to DWQ by the applicant, the applicant's authorized agent, or the project engineer. It is not necessary to send certificates from all of these. Applicant's Certification I, JV 1 - L. 6 (c(er , hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance and intent of the 401 Water Quality Certification and Buffer Rules, the j lans and specifications, and other supporting materials. Signature. II``jj????`//''????? Date: Agent's Certification I, , hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance and intent of the 401 Water Quality Certification and Buffer Rules, the approved plans and specifications, and other supporting materials. Signature: Date: If this project was designed by a Certified Professional I, , as a duly registered Professional (i.e., Engineer, Landscape Architect, Surveyor, etc.) in the State of North Carolina, having been authorized to observe (periodically, weekly, full time) the construction of the project, for the Permitee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance and intent of the 401 Water Quality Certification and Buffer Rules, the approved plans and specifications, and other supporting materials. Signature Registration No. Date Michael F. Easle or William G. Ross Jr., North Carolina Department of Environment d Natural Res Alan W. lipnek, Dir Divi t?.pf W Qua lr+??1 rE?M North Carolina Division of Water Quality, 401 Wetlands Certification Unit, 1650 Mail Service Center, Raleigh, NC 27699-1650 (Mailing Address) 2321 Crabtree Blvd., Raleigh, NC 27604-2260 (Location) 919-733-1786 (phone), 919-733-6893 (fax), http://h2o.enr.state.nc.us/ncwetiands/ . .le t1