Loading...
HomeMy WebLinkAboutNC0059439_Regional Office Physical File Scan Up To 10/2/2020Facilitv information NPDES permit #: NG0059439 Facility name: Sapphire Lakes WWTP # 2 WWTP class: I Biological (STSF) WWTP type: 0.0049 MGD wastewater treatment system with: (no septic tank on -site) 1000 gallon dosing tank with siphon bell; distribution manifold; 5' x 30' surface san alter with 9 laterals of 4-inch diameter drilled pvc and %-inch diameter vertical vents; tablet chlorinator; 1000 gallon chlorine contact chamber; tablet dechlorinator; and concrete step cascade. Annual Average Flow: The discharge is from 8 homes. There is usually no discharge, unless it rains. Collection System: Consists of the gravity sewer collection of gray water from the individual septic tanks of 8 homes, serving 12 non -permanent residents, located on the Fairway Villas. Development: Sapphire Lakes has 1450 acres and is a private, second home community with golfing, tennis and swimming pool. There is a total of 1000 acres with 590 lots, 84 multi-family/villa units, 8 guest quarters, and an 80 seat clubhouse. WWTP # 1 treats the wastewater from these connections. Sludge Management: Commercial hauler to the City of Brevard's WWTP. WWTP location: 1600 US Hwy 64; Sapphire, NC 28774; Near Roundtop Mountain Responsible official: Aubrey Deaver (owner as of Dec `06) A&D Water Service, Inc.; PO Box 1407; Pisgah Forest, NC 28768 Phone numbers 828-884-9772 Aubrey Deaver; A& D Water Service, Inc. 828-884-8632 " - fax (Ruth Whitmire) 828-507-9853 cell " - cell 828-891-7779 Gary Norton @ HVL Water Plant (works day shift) (h) 128 Maple Hill Rd Penrose NC 28766-9711 We V-" 5edo ea 5annhire THE PINNACLE RACQUET CLUB VILLAS RIVER PARK VILLAS COTTAGES AT NO.9 COTTAGES AT NO.2 21C I-, 450 B 62 f 46B g n 6B .73A k5B 56B 61B 6e 1.05A a5A 35A S7B doA 54B.. +a3A 6OB 678: e B. POCKY 5967 4B 3 o :BA 686 IxA/ B 3B 520 519 meA 6 98 COMMERCIAL AREA HILLTOP AT NO. 5 a3A e54 37C' La — up r VELOP THE MASTER LAND USE PLAN iMutel rand Use flans are eynamld delta,, which em r Ilhy modif d.ndi altered dddny the eeyeral yell ied— to build a community, a, Ne COmIIIIy'I response 1. I) Changing re0ullemenl5 0l poremment epencies and lirwcial inslitulbns. 2) The chanpinq needs 01 residents and recreational visitors: 3) =Ulion of Ile It- of the In of c0mmunity planning and dar,lopment, new re amn studies and lecn,oiogical mne.xim,I: �) Clang nth Ilnandal cpndltipns making pith, aileotions desirable to maintain the e00nomic health of the company's community demlopmenl prooln. While lots edition of the master land Use Plan Is Ihus a temporary design and not - Imae,' as Wet of the leg.: dacumenls and conlnetural cammi—rh, of the Company, it serves u.01 neat revised II the Campany's guidelines to location of cads, types 0t dwelling unit. w si,ghi f—ly lots d onddminlums. le-6 it and other --do, Iyeteme, drainage planning, m reatlonal laclllh— location, ulllitles design, and open space.11... two, Current c—thh, i.hwI t l thus he syllem ht .Ilycarried out in accordance with mil plan. However. it should he u,der,t0od that the developer in no way is uhllgaled to.lad or com p111e impmvemenu or amenities 0umently id -hued as "future-% The Company reserves the dghl le male anal plan change.. Sapphire Lakes. Inc. P.O. Boa<13D Sapphire. N.C. 28774 (704) 966-920n REVISED 9110/96 NOaZN 0 Soo 1000 GUEST QUARTERS FUTURE DEVELOPMENT — SCALE IN FEET Luther E. Smith And Associates, P.A. DAVIDC..HUNTLEYc&ASSOCIATES LAND PLANNING • LANDSCAPE ARCHITECTURE LAND SURVEYING ve"U_051(1� Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Ciolleen H. Sullins, Director - � fi S;i�'fi8r "Sim om "-+.�y1Y1SlOn .o�,Wat��:�s4.a�i a is ,m <4auu« aT✓.,ra^.v.'y:�sr�a.�ea,� wca .c ,vtt�f . f sa i->-. L Y�' . September 27, 2007 Mr. Aubrey L. Deaver A & D Water Service, Inc. P. O. Box 1407 Pisgah Forest, NC 28768 Subject: Issuance of NPDES Permit NCO059439 Sapphire Lakes WWTP #2 Transylvania County Dear Mr. Deaver: i 7n;.Rpm..itifl:.�4W1,:T�Fdf.+�ittFA.41wL.1a T�35.1R..42�: .,,.i�iB Division personnel have reviewed and approved your application for renewal of the subject ,permit. Accordingly, we are forwarding the attached NPDES discharge permit.. This permit is issued pursuant to the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement between North Carolina and the U.S. Environmental Protection Agency dated May 9, 1994 (or as subsequently amended). This final permit includes no substantial changes from the draft permit sent to you on August 1, 2007. However, its terms include the following change from those found in your current permit: • The permit includes a new daily maximum effluent limit for total residual chlorine (TRC). The limit shall become effective on May 1, 2009 (eighteen months following the effective date of the permit), but monitoring for TRC should continue as required under both the current and the renewed permits. If any parts, measurement frequencies or sampling requirements contained in this permit are unacceptable to you, you have the right to an adjudicatory hearing upon written request within thirty (30) days following receipt of this letter. This request must be in the form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings (6714 Mail Service Center, Raleigh, North Carolina 27699-6714). Unless such demand is made, this decision shall be final and binding. Please note that this permit is not transferable except after notice to the Division. The Division may require modification or.revocation and reissuance of the permit. This permit does not affect the legal requirements to obtain other permits which may be required by the Division of Water Quality or permits required by the Division of Land Resources, the Coastal Area Management Act or any other Federal or Local governmental permit that may be required.. If you have any questions concerning this permit, please contact Bob Sledge at telephone number (919) 733- 5083, extension 547. Sincerely, �1�r een H. Sullins cc: Central Files Unit NoorthCarolina Naturally North Carolina Division of Water Quality 1617 Mail Service Center Raleigh, NC 27699-1617 Phone (919) 733-7015 Internet: www.ncwaterquality.org Location: 512 N. Salisbury St. Raleigh, NC 27604 Fax (919) 733-2496 An Equal Opportunity/Affirmative Action Employer — 50% Recycled/100% Post Consumer Paper Customer Service 1-877-623-6748 Permit NCO059439 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY 1U91.7TIYi TO DISCHARGE WASTEWATER UNDER THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provisions of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, the A & D Water Service, Inc. is hereby authorized to discharge wastewater from a facility located at the Sapphire Lakes WWTP #2' Off US Highway 64 at Sapphire Near Round Top Mountain Transylvania County to receiving waters designated as James Creek in the Savannah River Basin in accordance with effluent limitations, monitoring requirements, and other conditions set forth in Parts I, II, III and IV hereof. This permit shall become effective November 1, 2007. This permit and authorization to discharge shall expire at midnight on August 31, 2012. Signed this day September 27, 2007. !% oleen H. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission Permit NC0059439 SUPPLEMENT TO PERMIT COVER SHEET All previous NPDES Permits issued to this facility, whether for operation or discharge are hereby revoked. As of this permit issuance, any previously issued permit bearing this number is no longer effective. Therefore, the exclusive authority to operate and discharge from this facility arises under the permit conditions, requirements, terms, and provisions included herein. A & D Water Service, Inc® is hereby authorized to: Continue to operate an existing 0.0049 MGD wastewater treatment system with the following components: ♦ Holding tanks ♦ Surface sand filter ♦ Chlorination The facility is located near Round Top Mountain at Sapphire Lakes Utility Company Plant #2 off US Highway 64 at Sapphire in Transylvania County. 2. Discharge from said treatment works at the location specified on the attached map into James Creek, classified C waters in the Savannah River Basin. Latitude: 35°06'33" Stream Class: C Longitude:82°58'35" Subbasin:031302 Quad # G7SW Receiving Stream: James Creek Facility a� Location: ; NC0059439-Sapphire Lakes Utility Co. Plant #2 Trans lvania CountV Permit NCO059439 A. (1.) EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS - FINAL During the period beginning on the effective date of this permit and lasting until expiration, the Permittee is authorized to discharge from outfall 001. Such discharges shall be limited and monitored by the Permittee as specified below: „ CHARACTERISTICS LIMITS , EQUIREMENT MONITORING RS r n_ Monthly Average" Daily s Maximum , Measurement Frequency, r Sample Type � Sample Location Flow 0.0049 MGD Weekly Instantaneous Influent or Effluent BOD, 5-day (20°C) . 30.0 mg/L 45.0 mg/L 2/Month Grab Effluent Total Suspended Residue 30.0 mg/L 45.0 mg/L 2/Month Grab Effluent NHs as N Monthly Grab Effluent Fecal Coliform (geometric mean) 200/100 ml 400/100 ml 2/Month Grab Effluent Total Residual Chlorinel 28 pg/L 2/Week Grab Effluent Temperature (°C) Weekly Grab Effluent pH2 2/Month Grab Effluent Footnotes: 1. The total residual chlorine limit will become applicable May 1, 2009 (eighteen months following the effective date of the permit). 2. The pH shall not be less than 6.0 standard units nor greater than 9.0 standard units. There shall be no discharge of floating solids or visible foam in other than trace amounts. NPDES Permit Standard Conditions Page 1 of 16 PART II STANDARD CONDITIONS FOR NPDES PERMITS Section A. Definitions 2/Month Samples are collected twice per month with at least ten calendar days between sampling events. 3 Week Samples are collected three times per week on three separate calendar days. ; Act or "the Act" The Federal Water Pollution Control Act, also known as the Clean Water Act, as amended, 33 USC 1251, et. seq. Annual Average The arithmetic mean of all "daily discharges" of a pollutant measured during the calendar year. In the case of fecal coliform, the geometric mean of such discharges. Arithmetic Mean The summation_ of the individual values divided by the number of individual values. B ass The known diversion of waste streams from any portion of a treatment facility including the collection system, which is not a designed or established or operating mode for the facility. Calendar Day The period from midnight of one day until midnight of the next day. However, for purposes of this permit, any consecutive 24-hour period that reasonably represents the calendar day may be used for sampling. Calendar Quarter One of the following distinct periods: Januarythrough March, April through June, July through September, and October through December. Composite Sample' A sample collected over a 24-hour period by continuous sampling or combining grab samples of at least 100 ml in such a manner as to result in a total sample representative of the wastewater discharge during the sample period The. Director may designate the most appropriate method (specific number and size of aliquots necessary, the time interval between grab samples, etc.) on a case -by -case basis. Samples may be collected manually or automatically. Composite samples may be obtained by the following methods: (1) Continuous: a single, continuous sample collected over a 24-hour period proportional to the rate of flow. (2) Constant time/variable volume: a series of grab samples collected at equal time intervals over a 24 hour period of discharge and combined proportional to the rate of flow measured at the time of individual sample collection, or (3) Variable time/constant volume: a series of grab samples of equal volume collected over a 24 hour period with the time intervals between samples determined by a preset number of, gallons passing the sampling point. Flow measurement between sample intervals shall he determined by use of a flow recorder and totalizer, and the preset gallon interval between sample collection fixed at no greater than 1/24 of the expected total daily flow at the treatment system, or (4) Constant time/constant volume: a series of grab samples of equal volume collected over a 24-hour period at a constant time interval. This method may only be used in situations where effluent flow rates vary less than 15 percent. The grab samples shall be taken at intervals of no greater than 20 minutes apart during any 24-hour period and must be of equal size and of no less than 100 milliliters. Use of this method requires prior approval by the Director. Version 8/1/2006 NPDES Permit Standard Conditions Page 2 of 16 In accordance with (4) above, influent grab samples shall not be collected more than once per hour. Effluent grab samples shall not be collected more than once per hour except at wastewater treatment systems having a detention time of greater than 24 hours. In such cases, effluent grab samples may be collected at intervals evenly spaced over the 24-hour period that are equal in number of hours to the detention time of the system in number of days. However, the interval between effluent grab samples may not exceed six hours nor the number of samples less than four during a 24-hour sampling period. Continuous flow measurement Flow monitoring that occurs without interruption throughout the operating hours of the facility. Flow shall be monitored continually except for the infrequent times when there may be no flow or for infrequent maintenance activities on the flow device. Daily Discharge The discharge of a pollutant measured during a calendar day or any 24-hour period that reasonably represents the calendar day for purposes of sampling. For pollutants measured in units of mass, the "daily discharge" is calculated as the total mass of the pollutant discharged over the day. The "daily discharge" concentration comprises the mean concentration for a 24-hour sampling period as either a composite sample concentration or the arithmetic mean of all grab samples collected during that period. (40 CFR 122.2) Daft Maximum The highest "daily discharge" for conventional and other non -toxicant parameters. NOTE: Permittees may not submit a "daily average" calculation [for determining compliance with permit limits] for toxicants. See the relevant Federal effluent guidelines] for the appropriate calculation interval. Daily Sampling Parameters requiring daily sampling shall be sampled 5 out of every 7 days per week unless otherwise specified in the permit. The Division expects that sampling shall be conducted on weekdays except where holidays or other disruptions of normal operations prevent weekday sampling. If sampling is required for all seven days of the week for any permit parameter(s), that requirement will be so noted on the Effluent Limitations and Monitoring Page(s). DWO or "the Division" The Division of Water Quality, Department of Environment and Natural Resources. EMC The North Carolina Environmental Management Commission. Facility Closure The cessation of wastewater treatment at a permitted facility, or the cessation of all activities that require coverage under the NPDES. Completion of facility closure will allow this permit to be rescinded. Geometric Mean The Nth root of the product of the individual values where N = the number of individual values. For purposes of calculating the geometric mean, values of "0" (or "< [detection level]') shall be considered = L Grab Sample Individual samples of at least 100 ml collected over a period of time not exceeding 15 minutes. Grab samples can be collected manually. Grab samples must be representative of the discharge (or the receiving stream, for instream samples). Hazardous Substance Any substance designated under 40 CFR Part 116 pursuant to Section 311 of the Clean Water Act Instantaneous flow measurement A measure of flow taken at the time of sampling, when both the sample and flow will be representative of the total discharge. Version 812006 NPDES Permit Standard Conditions Page 3 of 16 Monthly Average (concentration limitl The arithmetic mean of all "daily discharges" of a pollutant measured during the calendar month. In the case of fecal coliform, the geometric mean of such discharges. Permit Issuing_Authori_,ty The Director of the Division of Water Quality. Quarterly Average (concentration limitl The average of all samples taken over a calendar quarter. Severe propertydamage Substawial physical damage to property, damage to the treatment facilities which causes them to become inoperable, or substantial and permanent loss of natural resources which can reasonably be expected to occur in the absence of a bypass. Severe property damage excludes economic loss caused by delays in production. Toxic Pollutant. Any pollutant listed as toxic under Section 307(a)(1) of the Clean Water Act U set An incident beyond the reasonable control of the Permittee causing unintentional and temporary noncompliance with permit effluent limitations and/or monitoring requirements. An upset does not include noncompliance caused by operational error, improperly designedtreatment facilities, inadequate treatment ' facilities, lack of preventive maintenance, or careless orimproper operation. Weekly Average (concentration hmitl The arithmetic mean of all "daily discharges" of a pollutant measured during _the calendar week. In the case of fecal coliform, the geometric mean of such discharges. Section B. General Conditions L Duty to Comply The Permittee must comply with all conditions of this permit Any permit noncompliance constitutes a violation of the Clean Water Act and is grounds for enforcement action; for permit termination, revocation and reissuance, or modification; or denial- of a permit renewal application [40 CFR 122.41]. a. The Permittee shall comply with effluent standards or prohibitions established under section 307(a) of the Clean Water Act for toxic pollutants and with standards for sewage sludge use or disposal established under section 405(d) of the Clean Water Act within the time provided in the regulations that establish these standards or prohibitions or standards for sewage sludge use or disposal, even if the permit has not yet been modified to incorporate the requirement b. The Clean Water Act provides that any person who violates section 301, 302, 306, 307, 308, 318 or 405 of the Act, or any permit condition or limitation implementing any such sections in a permit issued under section 402, or any requirement imposed in a pretreatment program approved under sections 402(a)(3) or 402(b)(8) of the Act, is subject to a civil penalty not to exceed $25,000 per day for each violation. [40 CFR 122A1 (a) (2)] c. The Clean Water Act provides that any person who negligently violates sections 301, 302, 306, 307, 308, 318, or 405 of the Act, or any condition or limitation implementing any of such sections in a permit issued under section 402 of the Act, or any requirement imposed in a pretreatment program approved under section 402(a)(3) or 402(b)(8) of the Act, is subject to criminal penalties of $2,500 to $25,000 per day of violation, or. imprisonment of not more than 1 year, or both. In the case of a second or subsequent conviction for a negligent violation, a person shall be subject to criminal penalties of not more than $50,000 per day of violation, or by imprisonment of not more than 2 years, or both. [40 CFR 122.41 (a) (2)] Version 8/1/2006 NPDES Permit Standard Conditions Page 4 of 16 d. Any person who knowingly violates such sections, or such conditions or limitations is subject to criminal penalties of $5,000 to $50,000 per day of violation, or imprisonment for not more than 3 years, or both. In the case of a second or subsequent conviction for a knowing violation, a person shall be subject to criminal penalties of not more than $100,000 per day of violation, or imprisonment of not more than 6 years, or both. [40 CFR 122.41 (a) (2)] e. Any person who knowingly violates section 301, 302, 303, 306, 307, 308, 318 or 405 of the Act, or any permit condition or limitation implementing any of such sections in a permit issued under section 402 of the Act, and who knows at that time that he thereby places another person in imminent danger of death or serious bodily injury, shall, upon conviction; be subject to a fine of not more than $250,000 or imprisonment of not more than 15 years, or both. In the case of a second or subsequent conviction for a knowing endangerment violation, a person shall be subject to a fine of not more than $500,000 or by imprisonment of not more than 30 years, or both. An organization, as defined in section 309(c)(3)(B)(iu) of the CWA, shall, upon conviction of violating the imminent danger provision, be subject to a fine'of not more than $1,000,000 and can be fined up to $2,000,000 for second or subsequent convictions. [40 CFR 122.41 (a) (2)] f. Under state law, a civil penalty of not more than $25,000 per violation may be assessed against any person who violates or fails to act in accordance with the terms, conditions, or requirements of a permit [North Carolina General Statutes § 143-215.6A] g. Any person may be assessed an administrative penalty by the Administrator for violating section 301, 302, 306, 307, 3082 318 or 403 of this Act, or any permit condition or limitation implementing any of such sections in a permit issued under section 402 of this Act Administrative penalties for Class I violations are not to exceed $10,000 per violation, with the maximum amount of any Class I penalty assessed not to exceed $25,000. Penalties for Class II violations are not to exceed $10,000 per day for each day during which the violation continues, with the maximum amount of any Class II penalty not to exceed $125,000. [40 CFR 122.41 (a) (3)] 2. Duty to Mitigate The Permittee shall take all reasonable steps to rninirnie or prevent any discharge or sludge use or disposal in violation of this permit which has a reasonable likelihood of adversely affecting human health or the environment [40 CFR 122.41 (d)]. 3. Civil and Criminal Liability Except as provided in permit conditions on "Bypassing" (Part II. C. 4), "Upsets" (Part II. C. 5) and "Power Failures" (Part H. C. 7), nothing in this permit shall be construed to relieve the Permittee from any responsibilities, liabilities, or penalties for noncompliance pursuant to NCGS 143-215.3,143-215.6 or Section 309 of the Federal Act, 33 USC 1319. Furthermore, the Permittee is responsible for consequential damages, such as fish kills, even though the responsibility for effective compliance may be temporarily suspended. 4. Oil and Hazardous Substance Liability Nothing in this permit shall be construed to preclude the institution of any legal action or relieve the Permittee from any responsibilities, liabilities, or penalties to which the Permittee is or may be subject to under NCGS 143- 215.75 et seq. or Section 311 of the Federal Act, 33 USG 1321. Furthermore, the Permittee is responsible for consequential damages, such as fish kills, even though the responsibility for effective compliance may be temporarily suspended 5. Property Rights The issuance of this permit does not convey any property rights in either real or personal property, or any exclusive privileges, nor does it authorize any injury to private property or any invasion of personal rights, nor any infringement of Federal, State or local laws or regulations [40 CFR 122.41 6. Onshore or Offshore Construction This permit does not authorize or approve the construction of any onshore or offshore physical structures or facilities or the undertaking of any work in any navigable waters. 7. Severability Version 8112006 NPDES Permit Standard Conditions Page 5 of 16 The provisions of this permit are severable. If any provision of this permit, or the application of any provision of this permit to any circumstances, is held invalid, the application of such provision to other circumstances, and the remainder of this permit, shall not be affected thereby [NCGS 150B-23]. 8. Duty to Provide Information The Permittee shall furnish to the Permit Issuing Authority, within a reasonable time, any information which the Permit Issuing Authority may request to determine whether cause exists for modifying, revoking and reissuing, or terminating this permit or to determine compliance with this permit. The Permittee shall also furnish to the Permit Issuing Authority upon request, copies of records required by this permit [40 CFR 122.41 (h)]. 9. Duty to Reapply If the Permittee wishes to continue an activity regulated by this permit after the expiration date of this permit, the Permittee must apply for and obtain a new permit [40 CFR 122.41 (b)]. 10. Expiration of Permit The Pemzittee is not authorized to discharge after the expiration date. In order to receive automatic authorization to discharge beyond the expiration date, the Permittee shall submit such information, forms, and fees as are required by the agency authorized to issue permits no later than 180 days prior to the expiration date. Any Permittee that has not requested renewal at least 180 days prior to expiration, or any Permittee that does not have a permit after the expiration and has not requested renewal at least 180 days prior to expiration, will subject the Permittee to enforcement procedures as provided in NCGS 143-215.6 and 33 USC 1251 et. seq. 11. Sig2at= Reg&ements All applications, reports, or information submitted to the Permit Issuing Authority shall be signed and certified .[40 CPR 122.41 (k)]. a. All permit applications shall be signed as follows: (i) For a corporation: by a responsible corporate officer. For the purpose of this Section, a responsible corporate officer means: (a) a president, secretary, treasurer or vice president of the corporation in charge of a principal business function, or any. other person who performs similar policy or decision making functions for the corporation, or (b) the manager of one or more manufacturing, production, or operating facilities, provided, the manager is authorized to make management decisions which govern the operation of the regulated facility including having the explicit or implicit, duty of making major capital investment recommendations, and initiating and directing other comprehensive measures to assure long term environmental compliance with environmental laws and regulations; the manager can ensure that the necessary systems are established or actions taken to gather complete and accurate information for permit application requirements; and where authority to sign documents has been assigned or delegated to the manager in accordance with corporate procedures. (2) For a partnership or sole proprietorship: by a general partner or the proprietor, respectively; or (3) For a municipality, State, Federal, or other public agency: by either a principal executive officer or ranking elected official [40 CFR 122.22]. b. All reports required by the permit and other information requested by the Permit Issuing Authority shall be signed by a person described in paragraph a. above or by a duly authorized representative of that person. A person is a duly authorized representative only if: 1. The authorization is made in writing by a person described above; 2. The authorization specified either an individual or a position having responsibility for the overall operation of the regulated facility or activity, such as the position of plant manager, operator of a well -or well field, superintendent, a position of equivalent responsibility, or an individual or position having overall responsibility for environmental matters for the company. (A duly authorized representative may thus be either a named individual or any individual occupying a named position.); and 3. The written authorization is submitted to the Permit Issuing Authority [40 CFR 122.22] Version 6/1/2006 NPDES Permit Standard Conditions Page 6 of 16 c. Changes to authorization: If an authorization under paragraph (b) of this section is no longer accurate because a different individual or position has responsibility for the overall operation of the facility, a new authorization satisfying the requirements of paragraph (b) of this section must be submitted to the Director prior to or together with any reports, information, or applications to be signed by an authorized representative [40 CFR 122.22] d. Certification. Any person signing a document under paragraphs a. or b. of this section shall make the following certification (40 CFR 122.22]: 01 certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel property gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations.' 12. Permit Actions This permit may be modified, revoked and reissued, or terminated for cause. The filing of a request by the Permittee for a permit modification, revocation and reissuance, or termination, or a notification of planned changes or anticipated noncompliance does not stay any permit condition [40 CFR 122.41 (0]. 13. Permit Modification, Revocation and Resssuance, or Termination The issuance of this permit does not prohibit the permit issuing authority from reopening and modifying the permit, revoking and reissuing the permit, or terminating the permit as allowed by the laws, rules, and regulations contained in Title 40, Code of Federal Regulations, Parts 122 and 123; Title 15A of the North Carolina Administrative Code, Subchapter 2H .0100; and North Carolina General Statute 143-215.1 et A 14. Annual Administering and Compliance Monitoring Fee Requirements The Permittee must pay the annual administering and compliance monitoring fee within thirty days after being billed by the Division. Failure to pay the fee in a timely manner in accordance with 15A NCAC 2H.0105 (b) (2) may cause this Division to initiate action to revoke the permit Section C. Operation and Maintenance of Pollution Controls 1. Certified Operator Upon classification of the permitted facility by the Certification Commission, the Permittee shall employ a certified water pollution control treatment system operator in responsible charge (ORC) of the water pollution control treatment system. Such operator must hold a certification of the grade equivalent to or greater than the classification assigned to the water pollution control treatment system by the Certification Commission. The Permittee must also employ one or more certified Back-up ORCs who possess a currently valid. certificate of the type of the system. Backup ORCs must possess a grade equal to (or no more than one grade less than) the grade of the system [15A NCAC 8G.0201]. The ORC of each Class I facility must: ➢ Visit the facility at least weekly ➢ Comply with all other conditions of 15A NCAC 8G.0204. The ORC of each Class II, III and IV facility must: ➢ Visit the facility at least five days per week, excluding holidays ➢ Properly manage and document daily operation and maintenance of the facility ➢ Comply with all other conditions of 15A NCAC 8G.0204. Once the facility is classified, the Permittee shall submit a letter to the Certification Commission designating the operator in responsible charge: a. Within 60 calendar days prior to wastewater being introduced into a new system Version 81112006 NPDES Permit Standard Conditions Page 7 of 16 b. Within 120 calendar days of ➢ Receiving notification of a change in the classification of the system requiring the designation of a ' new ORC and back-up ORC ➢ A vacancy in the position of ORC or back-up ORC. 2. Proper Operation and Maintenance The Permittee shall at all times provide the operation and maintenance resources necessary to operate the existing facilities at optimum efficiency. The Permittee shall at all times properly operate and maintain all facilities and systems of treatment and control (and related appurtenances) which are installed or used by the Permittee to achieve compliance with the conditions of this permit. Proper operation and maintenance also includes adequate laboratory controls and appropriate quality assurance procedures. This provision requires the Permittee to install and operate backup or auxiliary facilities only when necessary to achieve compliance with the conditions of the permit [40 CFR 122.41 (e)]. 3. Need to Halt or Reduce not a Defense It shall not be a defense for a Permittee in an enforcement action that it would have been necessary to halt or reduce the permitted activity in order to maintain compliance with the condition of this permit [40 CFR 122.41 (c)]- 4. BBypassing_of Treatment Facilities a. Bypass not exceeding limitations [40 CFR 122.41 (m) (2)] The Permittee may allow any bypass to occur which does not cause effluent limitations to be exceeded, but only if it also is for essential maintenance to assure efficient operation. These bypasses are not subject to the provisions of Paragraphs b. and c. of this section. b. Notice [40 CFR 122.41 (m) (3)] (1) Anticipated bypass. If the Permittee knows in advance of the need for a bypass, it shall submit prior notice, if possible at least ten days before the date of the bypass; including an evaluation of the anticipated quality and effect of the bypass. (2) Unanticipated bypass. The Permittee shall submit notice of an unanticipated bypass as required in Part H. E. 6. (24-hour notice). c. Prohibition of Bypass (1) Bypass from the treatment facility is prohibited and the Permit Issuing Authority may take. enforcement action against a Permittee for bypass, unless: (A) Bypass was unavoidable to prevent loss of life, personal injury or severe property damage; (B). There were no feasible alternatives to the bypass, such as the use of auxiliary treatment facilities, retention of untreated wastes or maintenance during normal periods of equipment downtime. This condition is not satisfied if adequate backup equipment should have been installed in the exercise of reasonable engineering judgment to prevent a bypass which occurred during normal periods of equipment downtime or preventive maintenance; and (C) The Permittee submitted notices as required under Paragraph b. of this section. (2) Bypass from the collection system is prohibited and the Permit Issuing Authority may take enforcement action against a Pernittee for a bypass as provided in any current or future system -wide collection system permit associated with the treatment facility. (3) The Permit Issuing Authority may approve an anticipated bypass, after considering its adverse effects, if the Permit Issuing Authority determines that it will meet the three conditions listed above in Paragraph c. 0) of this section. 5. !!Users a. Effect of an upset [40 CFR 122.41 (n) (2)]: An upset constitutes an affirmative defense to an action brought for noncompliance with such technology based permit effluent limitations if the requirements of paragraph b. of this condition are met No determination made during administrative review of claims that Version 8✓112006 NPDES Permit Standard Conditions Page 8 of 16 noncompliance was caused by upset, and before an action for noncompliance, is final administrative action subject to judicial review. b. Conditions necessary for a demonstration of upset: A Permittee who wishes to establish the affirmative defense of upset shall demonstrate, through properly signed, contemporaneous operating logs, or other relevant evidence that: (1) An upset occurred and that the Permittee can identify the cause(s) of the upset; (2) The Permittee facility was at the time being properly operated; and (3) The Permittee submitted notice of the upset as required in Part II. E. 6. (b) of this permit. (4) The Permittee complied with any remedial measures required under Part II. B. 2. of this permit c. Burden of proof [40 CFR 122.41 (n) (4)]: The Permittee seeking to establish the occurrence of an upset has the burden of proof in any enforcement proceeding. 6. Removed Substances Solids, sludges, filter backwash, or other pollutants removed in the course of treatment or control of wastewaters shall be utilized/disposed of in accordance with NCGS 143-215.1 and in a manner such as to prevent any pollutant from such materials from entering waters of the State or navigable waters of the United States. The Permittee shall comply with all existing Federal regulations governing the disposal of sewage sludge. Upon promulgation of 40 CFR Part 503, any permit issued by the Permit Issuing Authority for the utilization/disposal of sludge may be, reopened and modified, or revoked and reissued, to incorporate applicable requirements at 40 CFR 503. The Permittee shall comply with applicable 40 CFR 503 Standards for the Use and Disposal of Sewage Sludge (when promulgated) within the time provided in the regulation, even if the permit is not modified to incorporate the requirement The Permittee shall notify the Permit Issuing Authority of any significant change in its sludge use or disposal practices. 7. Power Failures The Permittee is responsible for maintaining adequate safeguards (as required by 15A NCAC 2H.O124 — Reliability) to prevent the discharge of untreated or inadequately treated wastes during electrical power failures either by means of alternate power sources, standby generators or retention of inadequately treated effluent Section D. Monitoring; and Records 1. Representative Sampling Samples collected and measurements taken, as required herein, shall be characteristic of the volume and nature of the permitted discharge. Samples collected at a frequency less than daily shall be taken on a day and time that is characteristic of the discharge over the entire period the sample represents. All samples shall be taken at the monitoring points specified in this permit and, unless otherwise specified, before the effluent joins or is diluted by any other wastestream, body, of water, or substance. Monitoring points shall not be changed without notification to and the approval of the Permit Issuing Authority [40 CFR 122.41 (j)]. 2. Reporting Monitoring results obtained during the previous month(s) shall be summarised for each month and reported on a monthly Discharge Monitoring Report (DMR) Form (MR 1, 4 2, 3) or alternative forms approved by the Director, postmarked no later than the last calendar day of the month following the completed reporting period. The first DMR is due on the last day of the month following the issuance of the permit or in the case of a new facility, on the last day of the month following the commencement of discharge. Duplicate signed copies of these, and all other reports required herein, shall be submitted to the following address: NC DENR / Division of Water Quality / Water Quality Section ATTENTION: Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 Version 8/12006 NPDES Permit Standard Conditions Page 9 of 16 3. Flow Measurements Appropriate flow measurement devices and methods consistent with accepted scientific practices shall be selected and used to ensure the accuracy and reliability of measurements of the volume of monitored discharges. The devices shall be installed, calibrated and maintained to ensure that the accuracy of the measurements is consistent with the accepted capability of that type of device. Devices selected shall be capable of measuring flows with a maximum deviation of less than 10% from the true discharge rates throughout the range of expected discharge volumes. Flow measurement devices shall be accurately calibrated at a minimum of once per year and maintained to ensure that the accuracy of the measurements is consistent with the accepted capability of that type of device. The Director shall approve the flow measurement device and monitoring location prior to installation. Once -through condenser cooling water flow monitored by pump logs, or pump hour meters as specified in Part I of this permit and based on the manufacturer's pump curves shall not be subject to this requirement. 4. Test Procedures Test procedures for the analysis of pollutants shall conform to the EMC regulations (published pursuant to NCGS 143-215.63 et seq.), the Water and Air Quality Reporting Acts, and to regulations published pursuant to Section 304(g), 33 USC 1314, of the Federal Water Pollution Control Act (as Amended), and 40 CFR 136; or in the case of sludge use or disposal, approved under 40 CFR 136, unless otherwise specified in 40 CFR 503, unless other test procedures have been specified in this permit [40 CFR 122.41]. To meet the intent of the monitoring required by this permit, all test procedures must produce minimum detection and reporting levels that are below the permit discharge requirements and all data generated must be reported down to the minimum detection or lower reporting level of the procedure. If no approved methods are determined capable of achieving minimum detection and reporting levels below permit discharge requirements, then the most sensitive (method with the lowest possible detection and reporting.level) approved method must be used. 5. Penalties for Tampering The Clean Water Act provides that any person who falsifies, tampers with, or knowingly renders inaccurate, any monitoring device or method required to be maintained under this permit shall, upon conviction, be punished by a fine of not more than $10,000 per violation, or by imprisonment for not more than two pears per violation, or by both. If a conviction of a person is for a violation committed after a first conviction of such person under this paragraph, punishment is a fine of not more than $20,000 per day of violation, or by imprisonment of not more than 4 years, or both [40 CFR 122.41]. 6. Records Retention Except for records of monitoring information required by this permit related to the Permittee's sewage sludge use and disposal activities, which shall be retained for a period of at least five years (or longer as required by 40 CFR 503), the Permittee shall retain records of all monitoring information, including ➢ all calibration and maintenance records ➢ all original strip chart recordings for continuous monitoring instrumentation ➢ copies of all reports required by this permit ➢ copies of all data used to complete the application for this permit These records or copies shall be maintained for a period of at least 3 years from the date of the sample, measurement, report or application. This period may be extended by request of the Director at any time [40 CFR 122.41]. 7. Recording Results For each measurement or sample taken pursuant to the requirements of this permit, the Permittee shall record the following information [40 CFR 122.41]: a. The date, exact place, and time of sampling or measurements; b. The individual(s) who performed the sampling or measurements;. c. The date(s) analyses were performed; ' ' d. The individual(s) who performed the analyses; Version WV2006 NPDES Permit Standard Conditions Page 10 of 16 e. The analytical techniques or methods used; and . f. The results of such analyses. 8. Inspection and Entry The Permittee shall allow the Director, or an authorized representative (including an authorized contractor acting as a representative of the Director), upon the presentation of credentials and other documents as may be required by law, to; a. Enter upon the Pernittee's premises where a regulated facility or activity is located or conducted, or where records must be kept under the conditions of this permit; b. Have access to and copy, at reasonable times, any records that must be kept under the conditions of this P c. Inspect at reasonable times any facilities, equipment (including monitoring and control equipment), practices, or operations regulated or required under this permit; and d. Sample or monitor at reasonable times, for the purposes of assuring permit compliance or as otherwise authorized by the Clean Water Act, any substances or parameters at any location [40 CFR 122.4101 Section E Reporting Requirements L Change in Discharge All discharges authorized herein shall be consistent with the terms and conditions of this permit The discharge of any pollutant identified in this permit more frequently than or at a level in excess of that authorized shall constitute a violation of the permit 2. Planned Changes The Permittee shall give notice to the Director as additions to the permitted facility [40 CFR 122.41 (I)]. soon as possible of any planned physical alterations or Notice is required only when: a. The alteration or addition to a permitted facility may meet one of the criteria for new sources at 40 CFR 122.29 (b); or b. The alteration or addition could significantly change the nature or increase the quantity of pollutants discharged .This notification applies to pollutants subject neither to effluent limitations in the permit, nor to notification requirements under 40 CFR 122.42 (a) (1). c. The alteration or addition results in a significant change in the Permittee's sludge use or disposal practices, and such alteration, addition or change may justify the application of permit conditions that are different from or absent in the existing permit, including notification of additional use or disposal sites not reported during the permit application process or not reported pursuant to an approved land application plan. 3. Anticipated Noncompliance The Permittee shall give advance notice to the Director of any planned changes to the permitted facility or other activities that might result in noncompliance with the permit [40 CFR 122.41 (1) (2)]. 4. Transfers This permit is not transferable to any person except after notice to the Director. The Director may require modification or revocation and reissuance of the permit to document the change of ownership. Any such action may incorporate other requirements as may be necessary under the Clean Water Act [40 CFR 122.41 (I) (3)]. 5. Monitoring Reports Monitoring results shall be reported at the intervals specified elsewhere in this permit [40 CFR 122.41 (1) (4)]. a. Monitoring results must be reported on a Discharge Monitoring Report (DMR) (See Part II. D. 2) or forms provided by the Director for reporting results of monitoring of sludge use or disposal practices. b. If the Permittee monitors any pollutant more frequently than required by this permit, the results of such monitoring shall be included in the calculation and reporting of the data submitted on the DMR. Version 8/1/2006 NPDES Permit Standard Conditions Page 11 of 16 6. Twenty-four Hour Reporting a. The Permittee shall report to the Director or the appropriate Regional Office any noncompliance that potentially threatens public health or the environment. Any information shall be provided orally within 24 hours from the time the Permittee became aware of the circumstances. A written submission shall also be provided within 5 days of the time the Permittee becomes aware of the circumstances. The written submission shall contain a description of the noncompliance, and its cause; ,the period of noncompliance, including exact dates and times, and if the noncompliance has not been corrected, the anticipated time it is expected to continue; and steps taken or planned to reduce, eliminate, and prevent reoccurrence of the noncompliance [40 CFR 122.41 (1) (6)]. b. The Director may waive the written report on a rase -by -case basis for reports under this section if the oral report has been received within 24 hours. c. Occurrences outside normal business hours may also be reported to the Division's Emergency Response personnel at (800) 662-7956, (800) 858-0368 or (919) 733-3300. 7. Other Noncompliance The Permittee shall report all instances of noncompliance not reported under PartII. E. 5 and 6. of this permit at the time monitoring reports are submitted. The reports shall contain the information listed in Part II. E. 6. of this permit [40 CFR 122.41 0) (7)]. i 8. Other Information Where the Permittee becomes aware that it failed to submit any relevant facts in a permit application, or submitted incorrect information in a permit application or in any report to the Director, it shall promptly submit such facts or information [40 CFR 122.41 0) (8)]. 9. Noncompliance Notification The Pernuttee shall report by telephone to either the central office or the appropriate regional office of the Division as soon as possible, but in no case more than 24 hours or on the next working day following the occurrence or first knowledge of the occurrence of any of the following. a. Any occurrence at the water pollution control facility which results in the discharge of significant amounts of wastes which are abnormal in quantity or characteristic, such as the dumping of the contents of a sludge digester, the known passage. of a slug of hazardous substance through the facility; or any other unusual circumstances. b. Any process unit failure, due to known or unknown reasons, that render the facility incapable of adequate wastewater treatment such as mechanical or electrical failures of pumps, aerators, compressors, etc. c. Any failure of a pumping station, sewer line, or treatment facility resulting ins' a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Persons reporting such occurrences by telephone shall also file a written report within 5 days following first knowledge of the occurrence. 10. Availability of Reports Except for data determined to be confidential under NCGS 143-215.3 (a)(2) or Section 308 of the Federal Act, 33 USC 1318, all reports prepared in accordance with the terms shall be available for public inspection at the offices of the Division. As required by the Act, effluent data shall not be considered confidential Knowingly making any false statement on any such. report may result in the imposition of criminal penalties as provided for in NCGS 143-2151 (b)(2) or in Section 309 of the Federal Act 11. Penalties for Falsification of Reports The Clean Water Act provides that any person who knowingly makes any false statement, representation, or certification in any record or other document submitted or required to be maintained under this permit, including monitoring reports or reports of compliance or noncompliance shall, upon conviction, be punished by a fine of Version 8/1/2006 NPDES Permit Standard Conditions Page 12 of 16 not more than $25,000 per ;violation, or by imprisonment for not more than two years per violation, or by both (40 CFR 122.41). 12. Annual Performance Reports Permittees who own or operate facilities that collect or treat municipal or domestic waste shall provide an annual report to the Permit Issuing Authority and to the users/customers served by the Permittee (NCGS 143-215.1C). The report shall summarize the performance of the collection or treatment system, as well as the extent to which the facility was compliant with applicable Federal or State laws, regulations and rules pertaining to water quality. The report shall be provided no later than sixty days after the end of the calendar or fiscal year, depending upon which annual period is used for evaluation. PART III OTHER REQUIREMENTS Section A. Construction The Permittee shall not commence construction of wastewater treatment facilities, nor add to the plant's treatment capacity, nor change the treatment proces(es) utilized at the treatment plant unless the Division has issued an Authorization to Construct (AtC) permit Issuance of an AtC will not occur until Final Plans and Specifications for the proposed construction have been submitted by the Permittee and approved by the Division. Section B. Groundwater Monito jW The Permittee shall, upon written notice from the Director, conduct groundwater monitoring as may be required to determine the compliance of this NPDES permitted facility with the current groundwater standards. Section C. Changes in Discharges of Toxic Substances The Permittee shall notify the Permit Issuing Authority as soon as it knows or has reason to believe (40 CFR 122.42): a. That any activity has occurred or will occur which would result in the discharge, on a routine or frequent basis, of any toxic pollutant which is not limited in the permit, if that discharge will exceed the highest of the following "notification levels"; (1) One hundred micrograms per liter 000 µg/L); (2) Two hundred micrograms per liter (200 µg/L) for acrolein and acrylonitrile; five hundred micrograms per liter (500 µg/L) for 2.4-dinitrophenol and for 2-methyl-4.6-dinitrophenol; and one milligram per liter (1 mg/L) for antimony; (3) Five times the maximum concentration value reported for that pollutant in the permit application. b. That any activity has occurred or will occur which would result in any discharge, on a non -routine or infrequent basis, of a toxic pollutant which is not limited in the permit, if that discharge will exceed the highest of the following "notification levels"; 0) Five hundred micrograms per liter (500 µg/L); (2) One milligram per liter 0 mg/L) for antimony; (3) Ten times the maximum concentration value reported for that pollutant in the permit application. Section D. Evaluation of Wastewater Discharge Alternatives The Permittee shall evaluate all wastewater disposal alternatives and pursue the most environmentally sound alternative of the reasonably cost effective alternatives. If the facility is in substantial non-compliance with the terns and conditions of the NPDES permit or governing rules, regulations or laws, the Permittee shall submit a report in such form and detail as required by the Division evaluating these alternatives and a plan of action within 60 days of notification by the Division. Section E. Facility Closure Requirements The Permittee must notify the Division at least 90 days prior to the closure of any wastewater treatment system covered by this permit The Division may require specific measures during deactivation of the system to prevent Version 8112006 NPDES Permit Standard Conditions Page 13 of 16 adverse impacts to waters of the State. This permit cannot be rescinded while any activities requiring this permit continue at the permitted facility. PART IV SPECIAL CONDITIONS FOR MUNICIPAL FACILITIES Section A. Publicly Owned Treatment Works (POTWs) All POTWs must provide adequate notice to the Director of the following 1. Any new introduction of pollutants into the POTW from an indirect discharger which would be subject to section 301 or 3D6 of CWA if it were directly discharging those pollutants; and 2. Any substantial change in the volume or character of pollutants being introduced by an indirect discharger as influent to that POTW at the time of issuance of the permit 3. For purposes of this paragraph, adequate notice shall include information on (1) the quality and quantity of effluent introduced into the POTW, and (2) any anticipated impact of the change on the quantity or quality of effluent to be discharged from the POTW. Section B. Municipal Control of Pollutants from Industrial Users Effluent limitations are listed in Part I of this permit Other pollutants attributable to inputs, from industries using the municipal system may be present in the Permittee's discharge. At such time as sufficient information becomes available to establish limitations for such pollutants, this permit may be revised to specify effluent limitations for any or all of such other pollutants in accordance with best practicable technology or water quality standards. 2. Under no circumstances shall the Permittee allow introduction of the following wastes in the waste treatment system: a. Pollutants which create a fire or explosion hazard in the POTW, including, but not limited to, wastestreams with a closed cup flashpoint of less than 140 degrees Fahrenheit or 60 degrees Centigrade using the test methods specified in 40 CFR 261.21; b. Pollutants which will cause corrosive structural damage to the POTW, but in no case Discharges with pH lower than 5.0, unless the works is specifically designed to accommodate such Discharges;' C. Solid or viscous pollutants in amounts which will cause obstruction to the flow in the POTW resulting in Interference; d. Any pollutant, including oxygen demanding pollutants (BOD, etc.) released in a Discharge at a flow rate and/or pollutant concentration which will cause Interference with ;the POTW; e. Heat in amounts which will inhibit biological activity in the POTW resulting in Interference, but in no case heat in such quantities that the temperature at the POTW Treatment Plant exceeds 400C (104°F) unless the Division, upon request of the POTW, approves alternate temperature limits; f. Petroleum oil, nonbiodegradable cutting oil, or products of mineral oil origin in amounts that will cause interference or pass through; g. Pollutants which result in the presence of toxic gases, vapors, or fumes within the POTW in a quantity that may cause acute worker health and safety problems; h. Any trucked or hauled pollutants, except at discharge points designated by the POTW. 3. With regard to the effluent requirements listed in Part I of this permit, it may be necessary for the Permittee to supplement the requirements of the Federal Pretreatment Standards (40 CFR, Part 403) to ensure compliance by the Permittee with all applicable effluent limitations. Such actions by the Permittee may be necessary regarding some or all of the industries discharging to the municipal system. 4. The Permittee shall require any industrial discharges sending influent to the permitted system to meet Federal Pretreatment Standards promulgated in response to Section 307(b) of the Act Prior to accepting wastewater from any significant industrial user, the Permittee shall either develop and submit to the Version 81112006 NPDES Permit Standard Conditions Page 14 of 16 Division a Pretreatment Program for approval per 15A NCAC 2H .0907(a) or modify an existing Pretreatment Program per 15A NCAC 2H .0907(b). 5. This permit shall be modified, or alternatively, revoked and reissued, to incorporate or modify, an approved POTW Pretreatment Program or to include a compliance schedule for the development of a POTW Pretreatment Program as required under Section 402(b)(8) of the Clean Water Act and implementing regulations or by the requirements of the approved State pretreatment program, as appropriate. Section C. Pretreatment Programs Under authority of sections 307(b) and (c) and 402(b)(8) of the Clean Water Act and implementing regulations 40 CFR Part 403, North Carolina General Statute 143-215.3 (14) and implementing regulations 15A NCAC 2H .0900, and in accordance with the approved pretreatment program, all provisions and regulations contained and referenced in the Pretreatment Program Submittal are an enforceable part of this permit The Permittee shall operate its approved pretreatment program in accordance with Section 402(b)(8) of the Clean Water Act, the Federal Pretreatment Regulations 40 CFR Part 403, the State Pretreatment . Regulations 15A NCAC 2H .0900, and the legal authorities, policies, procedures, and financial provisions contained in its pretreatment program submission and Division approved modifications there of. Such operation shall include but is not limited to the implementation of the following conditions and requirements: 1. Sewer Use Ordinance (SUO) The Permittee shall maintain adequate legal authority to implement its approved pretreatment program. 2. Industrial Waste Survey W� Sl The Permittee shall update its Industrial Waste Survey (IWS) to include all users of the sewer collection system at least once every five years. 3. Monitoring Plan The Permittee shall implement a Division -approved Monitoring Plan for the collection of facility specific data to be used in a wastewater treatment plant Headworks Analysis (HWA) for the. development of specific pretreatment local limits. Effluent data from the Plan shall be reported on the DMRs (as required by Part II, Section D, and Section E.S.). 4. Headworks Analysis aMA-) and Local Limits The Permittee shall obtain Division approval of a Headworks Analysis (HWA) at least once every five years, and as required by the Division. Within 180 days of the effective date of this permit (or any subsequent permit modification) the Permittee shall submit to the Division a written technical evaluation of the need to revise local limits (Le., an updated HWA or documentation of why one is not needed) [40 CFR 122.44]. The Permittee shall develop, in accordance with 40 CFR 403.5(c) and 15A NCAC 2H .0909, specific Local Limits to implement the prohibitions listed in 40 CFR 403.5(a) and (b) and 15A NCAC 2H .0909. 5. Industrial User Pretreatment PermitsIUP) & Allocation Tables In accordance with NCGS 143-215.1, the Permittee shall issue to all significant industrial users, permits for operation of pretreatment equipment and discharge to the Permittee's treatment works. These permits shall contain limitations, sampling protocols, reporting requirements, appropriate standard and special conditions, and compliance schedules as necessary for the installation of treatment and control technologies to assure that their wastewater discharge will meet all applicable pretreatment standards and requirements. The Permittee shall maintain a current Allocation Table (AT) which surnmari es the results of the Headworks Analysis (HWA) and the limits from all Industrial User Pretreatment Permits (AJP). Permitted IUP loadings for each parameter cannot `exceed the treatment capacity of the POTW as determined by the HWA. Version 8/12W6: NPDES Permit Standard Conditions Page 15 of 16 6. Authorization to Construct (&Q The Permittee shall ensure that an Authorization . to Construct permit (AtC) is issued to all applicable industrial users for the construction or modification of any pretreatment facility. Prior to. the issuance of an AtC, the proposed pretreatment facility and treatment process must be evaluated for its capacity to comply with all Industrial User Pretreatment Permit TN) limitations. 7. POTW Inspection & Monitoring of their SIUs The Permittee shall conduct inspection, surveillance, and monitoring activities as described in its Division approved pretreatment program in order to determine, independent of information supplied by industrial users, compliance with applicable pretreatment standards. The Permittee must: a. Inspect all Significant Industrial Users (SIUs) at least once per calendar year, and b. Sample all Significant Industrial Users (SIUs) at least twice per calendar year for all permit - limited pollutants, once during the period from January 1 through June 30 and once during the period from July 1 through December 31, except for organic compounds which shall be sampled once per calendar year, . 8. SIU Self Monitoring and Reporting The Permittee shall require all industrial users to comply with the applicable monitoring and reporting requirements outlined in the Division -approved pretreatment program, the industry's pretreatment permit, or in 15A NCAC 2H .0908. 9. Enforcement Response Plan = The Permittee shall enforce and obtain appropriate remedies for violations of all pretreatment standards promulgated pursuant to section 307(b) and (c) of the Clean Water Act (40 CPR 405 et. seq.), prohibitive discharge standards as set forth in 40 CFR 403.5 and 15A NCAC 2H .0909, and specific local limitations. All enforcement actions shall be consistent with the Enforcement Response Plan TM) approved by the Division. 10. Pretreatment Annual Reports (PAR The Permittee shallreport to the Division in accordance with 15A NCAC 2H .0908. In lieu of submitting annual reports, Modified Pretreatment. Programs developed under 15A NCAC 2H .0904 (b) may be required to meet with Division personnel periodically to discuss enforcement of pretreatment requirements and other pretreatment implementation issues. For all other active pretreatment programs, the Permittee shall submit two copies of a Pretreatment Annual Report (PAR) describing its pretreatment activities over the previous twelve months to the Division at the following address: NC DENR / DWQ / Pretreatment Unit 1617 Mail Service Center Raleigh, NC 27699-1617 These reports shall be submitted according to a schedule established by the Director and shall contain the following. a.) Narrative A brief discussion of reasons for, status of, and actions taken for all Significant Industrial Users (SIUs) in Significant Non -Compliance (SNC); b.) Pretreatment Program Summ= (PPS) A pretreatment program summary (PPS) on specific forms approved by the Division; c.) Significant Non -Compliance Roort (SNCR� The nature of the violations and the actions taken or proposed to correct the violations on specific forms approved by the Division; d.) Industrial Data Summary Forms O SF) VeWon 811/2006 NPDES Permit Standard Conditions Page 16 of 16 Monitoring data from samples collected by both the POTW and the Significant Industrial User (SIU). These analytical results must be reported on Industrial Data Summary Forms (IDSF) or other specific format approved by the Division; e.) Other Information Copies of the POTW's allocation table, new or modified enforcement compliance schedules, public notice of SIUs in SNC, and any other information, upon request, which in the opinion of the Director is needed to determine compliance with the pretreatment implementation requirements of this permit; 11. Public Notice The Permittee shall publish annually a list of Significant Industrial Users (SIUs) that were in Significant Non -Compliance (SNC) as defined in the Permittee's Division -approved Sewer Use Ordinance with applicable pretreatment requirements and standards during the previous twelve month period. This list shall be published within four months of the applicable twelve-month period 12. Record KeWin� The Perrnittee shall retain for a *+ inimum of three years records of monitoring activities and results, along with support information including general records, water quality records, and records of industrial impact on the POTW. 13. Funding and Financial Report The Permittee shall maintain adequate funding and staffing levels to accomplish. the objectives of its approved pretreatment program. 14. Modification to Pretreatment ProWMs Modifications to the approved pretreatment program including but not limited to local limits modifications, POTW monitoring of their Significant Industrial Users (SIUs), and Monitoring Plan modifications, shall be considered a permit modification and shall be governed by 15 NCAC 2H .0114 and 15A NCAC 2H .0907. Version IV12006 a'eueflt- F `NATF O�0 9QG Michael F. Easley, Governor y William G. Ross Jr., Secretary > r North Carolina Department of Environment and Natural Resources ,flan e-c ✓c -. W.`Kliiriek; P.& Direct6r 'Di of Water Quality p � � " AP April 2 3 2007 120, 2007 Aubrey Deaver [? WA T ER QUALITY SECTION A&D Water Service, Inc. ASHEVILLE REGIOf','AL OFFICE P.O. Box 1407 - -- Pisgah Forest, NC 28768 Subject: Receipt of permit renewal application NPDES Permit NCO059439 Sapphire Lakes WWTP #2 Transylvania County Dear Mr. Deaver: The NPDES Unit received your permit renewal application on April 20, 2007. A member of the NPDES Unit will review your application. They will contact you if additional information is required to complete your permit renewal. You should expect to receive a draft permit approximately 30-45 days before your existing permit expires. The requirements in your existing permit will remain in effect until the permit is renewed (or the Division takes other action). If you have any additional questions concerning renewal of the subject permit, please contact me at (919) 733-5083, extension 363 or 350. Sincerely, 0 0 . b4'�� Carolyn Bryan Point Source Branch cc: CENTRAL FILES lie egional •:ffic� /tSusfac 'h;ate� Protection NPDES Unit "oRhCaro ina dvatun"ly North Carolina Division of Water Quality 1617 Mail Service Center Raleigh, NC 2769971617 Phone (919) 733-7015 Customer Service Intemet: h2o.enr.state.nc.us 512 N. Salisbury St. Raleigh, NC 27604 FAX (919) 733-2496 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer— 50% Recycled/10% Post Consumer Paper A & D Water Service, Inc. P.O. Box 1407 Pisgah Forest, NC 28768 828-884-9772 Fax 828-884-8632 April 18, 2007 Mrs. Carolyn Bryant NC DENR/DWQ/Point Source Brach 1617 Mail Service Center Raleigh, NC 27699-1617 RE: Renewal NPDES Applications: NCO059439 & NCO059421 Dear Mrs. Bryant, Enclosed please find renewal NPDES Applications for NCO059439 & NC0059421. Sludge is disposed of by a sludge pumper at an approved sludge handling facility. If you have any questions, please call me at 828-884-9772. Sincerely, Aubrey L. Deaver s NPDES APPLICATION - FORM D For privately owned treatment systems treating 100% domestic wastewaters <1.0 MGD Mail the complete application to: N. C. Department of Environment and Natural Resources .:'Division of. Water Quality / NPDES Unit. - 1617 Mail Service Center, Raleigh, NC .27699-1617 NPDES Permit C00� Please print or type. 1. Contact Information: Owner Name A&D Water.. Service, Inc.. Facility Name Sapphire Takes WTVTP #2 Mailing Address P.O. Box 1407 City Pisgah Forest i State / Zip Code 1N('. 2.8768 Telephone Number (8 2 8) 8 84 - 9 7 7 2 Fax Number (828). 884-8632 e-mail Address admaint@citcom.net 2. Location of facility producing discharge: Check here if same address as above ❑ Street Address or State Road Off US Hwy 64 at Sapphire near City Round Top Mountain State /Zip Code Sapphire, NC 28774 County Translyvania - County'; 3. Operator Information: Name of the firm, public organization or other entity that operates the facility. (Note that this is not referring to the Operator in Responsible Charge or ORC) Name .A&D Water Service, Inc Mailing Address P.O. Box 1407 City Pisgah Forest State / Zip Code Telephone Number Fax Number NC 287'68 ( 828) 884-9772 ( 828) 8847-8632 1 of 3 Form-D 4/05 - 'APDES APPLICATION = FORM D For privately owned treatment systems treating 100% domestic wastewaters <1.0 MGD 4. Description of wastewater: Facility Generating Wastewater(check all that apply):` Industrial ❑ Number of Employees Commercial ❑ Number of Employees Residential ® Number of Homes 8 School ❑ Number of Students/Staff Other ❑ Explain: Describe the source(s) of wastewater (example: subdivision, mobile home park, shopping centers, restaurants, etc.): Standard Domestic Wastes From Hpmas Population served: 12 S. Type of collection system ❑ Separate (sanitary sewer only) ❑ Combined (storm sewer and sanitary sewer) 6. Outfall Information:. . Number of separate discharge points 1 Outfall Identification number(s) 001 Is the outfall equipped with a diffuser? ® Yes ❑ No 7. Name of receiving stream(s) (Provide a map showing the exact location of each outfall): James Creek, -classified C waters in -the Savannan River Basin S. Frequency of Discharge: ❑ Continuous Intermittent If intermittent: Days per week discharge occurs: varies Duration: 10 mins . 9. Describe the treatment system List all installed components, including capacities, provide design removal for BOD, TSS, nitrogen and phosphorus. If the space provided is not sufficient, attach the description of the treatment system in a separate sheet ofpaper. 0.0049 MGD WWT System with holding tanks, surface sand filters & chlorination. 2of3 Form-D 4/05 NPDES APPLICATION FORM D For privately owned treatment systems treating 100% domestic wastewaters <1.0 MGD 10. Flow Information: Treatment Plant Design flow .0049MGD Annual Average _daily flow 0 & MGD (for the previous 3 years) Maximum daily. flow 0.-00010 MGD (for the previous 3 years) One occurrance in 3 yrs . 11. Is this facility located on Indian country? .❑ Yes ® No 12. Effluent Data Provide data for the parameters listed. Fecal Coliform, Temperature. and pH shall be grab samples, for all other parameters 24-hour composite sampling shall be used. If more than one analysis is reported, report daily maximum and monthly average. If only one analysis is reported, report as daily maximum. Parameter Daily Maximum Monthly Average Units of Measurement Biochemical Oxygen Demand (SODS) 4.4 4.4 Mg/1 Fecal Coliform 59 59 # of colonies Total Suspended Solids <. 2 .0 2 .0 Mg/1 Temperature (Summer) 13.2 13.2 o c Temperature (Winter) pH 6.5 1 6.5 su 13. List all permits, construction approvals and/or applications: Type Permit Number Type Hazardous Waste (RCRA) NESHAPS (CAA) UIC (SDWA) Ocean Dumping (MPRSA) NPDES NCO 0 5 9 4 3 9 Dredge or fill (Section 404 or CWA) PSD (CAA) Other Non -attainment program (CAA) 14. APPLICANT CERTIFICATION Permit Number I certify that I am familiar with the information contained in the . application and that to the best of my knowledge and belief such information is true, complete, and accurate. Aubrey L. Deaver President Printed game of Person --Signing Title of Applicant 04/18/.07 Date North Carolina General Statute 143-215.6 (b)(2) states: Any person who knowingly makes any false statement representation, or certification in any application, record, report, plan, or other document files or required to be maintained under Article 21 or regulations of ,the Environmental Management Commission implementing that Article, or who falsifies, tampers with, or knowly renders inaccurate any recording or monitoring device or method required to be operated or maintained under Article 21 or regulations of the Environmental Management Commission -implementing that Article; shall be guilty of a misdemeanor punishable by a fine not to exceed $25,000, or -by imprisonment not to exceed six months, or by both. (18 U.S.C. Section 1001 provides a punishment by a fine of not more than $25,000 or imprisonment not more than 5 years, or both, for a similar offense.) 3 of 3 Form-D 4/05 OC PRIORITY PROJECT: I No x IF YES, SOC NUMBER TO: PERMITS AND ENGINEERING UNIT WATER QUALITY SECTION ATTENTION: Dana Bolden DATE: May 18, 1994 NPDES STAFF REPORT AND RECOMMENDATION COUNTY Transylvania PERMIT NUMBER NCO059439 PART I - GENERAL INFORMATION 1. 2. 3. Facility and Address: Sapphire Lakes Utility Co., Inc. 1529 Horseshoe Drive Columbia, South Carolina 29224 Date of Investigation: March 4, 1994 Report Prepared By: Kerry S. Becker 4. Persons Contacted and Telephone Number: Wayne Bryson 704-884-7512' 5. Directions to Site: The facility is located adjacent to James Creek south of U.S. Hwy 64 approx. 1.5 miles west. of Bohaynee Rd. (Hti�;T. 281 S.). 6. Discharge Point(s), List for all discharge points: Latitude: 350 06' 33" Longitude: 820 58' 35" Attach a USGS map extract and indicate treatment facility site and discharge point on map. U.S.G.S. Quad No. 185-SW U.S.G.S. Quad Name Reid, N.C. 7. Site size and expansion area consistent wih application? x Yes No If No, explain: Page 1. N 00 8. Topography (relationship to flood plain included): Rolling 9. Location of nearest dwelling: >100 ft.. 10. Receiving stream or affected surface waters: James Creek a. Classification: C b. River Basin and Subbasin No.: SAV 03-13-02 C. Describe receiving stream features and pertinent downstream uses: James Creek is a swift moving, rocky; bottom stream that drains mountainous terrain. The area is primarily rural, sparsely populated with seasonal homes. The creek joins the Horsepasture River approximately 1/2 mile below the Sapphire Lakes plant #2 discharge point. PART II - DESCRIPTION OF DISCHARGE AND TREATMENT WORKS 1. a. Volume of wastewater to be permitted 0.0050 MGD (Ultimate Design Capacity) b. What is the current permitted capacity of the Wastewater Treatment facility? 0.0050 MGD C. Actual treatment capacity of the current facility (current design capacity 0.0050 MGD d. Date(s) and construction activities allowed by previous Authorizations to Construct issued in the previous two years: None issued. e. Please provide a description of existing or substantially constructed wastewater treatment facilities: The existing facility consists of septic tanks, distribution box, surface sand filter, and effluent chlorination. f. Please provide a description of proposed wastewater treatment facilities: None proposed. g. Possible toxic impacts to surface waters: Chlorine 2. Residuals handling and utilization/disposal scheme: Commercial septic tank cleaning firm. 3. Treatment plant classification (attach completed rating sheet): Class I 4.. SIC Codes(s): 4952 Page 2 *• Wastewater.Code(s) of actual wastewater, not particular facilities i.e., non -contact cooling water discharge from a metal plating company would be 14, not 56. Primary 06 Secondary Main Treatment Unit Code: 440-7 PART III - OTHER PERTINENT INFORMATION 1. Alternative Analysis Evaluation: Has the facility evaluated all of the non -discharge options available. Please provide regional perspective for each option evaluated. Spray Irrigation: Buffer distances, land size not available. Connection to Regional Sewer System: No regional sewer is located within proximity. Subsurface: Land size not available; soils may not be suitable Other disposal options: PART IV - EVALUATION AND RECOMMENDATIONS The facility has maintained compliance with permit limits for the past year. The Asheville Regional Office recommends renewal of the NPDES permit for the Sapphire Lakes Plant #2." i Signature f Report,Preparer Yi�(ter Quality Regional Supervisor _�_ 19-4,IC4 /1_' Date Page 3 Staff Review an Evaluation NPDES Wastewater Permit FACILITY INFORMATION Facility Sapphire Lakes Utility Co., Inc. -Plant II NPDES No. NC0059439 Design Flow (MGD) 0.0049 Facility Class I STREAM CHARACTERISTICS Stream Name James Creek Stream Class C Sub -basin 031302 Drainage Area (mil) 0.41 S7Q10 (cfs) 0.6 W7Q10 (cfs) 0.4 30Q2 (cfs) 0.7 IWC (%) 1.27 rProposed Changes Parameters Affected Basis for than e(s) note Compliance Schedule: none Special Condition(s): none Permits & Engineering Comments: This is a permit renewal for a sand filter system. No problems were noted in the last renewal. Facility appears to be in compliance with pe . 't limits. P&E recommends renewal. Prepared bye Xi w Regional Office Evaluation and Recommendations: NPDES WASTE LOAD ALLOCATION PERMIT NO.: NCO05q439 Facility Status: PROPOSE (circle one) Permit Status: MOOFiCATMN Uwp'ERMrrrED NEW (circle one) MaJor llliuo;�_ Pipe No: 00� Design ,Capacity (MGD): 0• 0 9?? Domestic M of Flow): /02 Industrial (% of Flow): Comments: RECEIVING STREAM: L Class: Sub-,ilej ;rcocr�e�{Y ojt30Z Sub -Basin: Reference USGS Quad: -7 SA _(please attach) County: Regional Office: ®i Fa Me. Ra Wa WI WS (circle one) rzlz , Date: z fo 9 Requested By: Prepared By: Date: S l Y 4 Reviewed BY: —Date: s��8 Modeler Date Rec. Drainage Area (m?) O•KlD Avg. Streamflow (cfs): 1.�0 7Q10 (cfs) 0-6 Winter 7Q10 (cfs) 0.LI 30Q2 (cfs), 020 Toxicity Limits: IWC _— (circle one) Acute / Chronic Instream Monitoring:) VED Parameters n 21,t, c, lion Upstream _�_[ Downstream Location C' A Location ,Asshe��ille ,['I�rtti ffilce Car6na Effluent Characteristics Summer Winter BODE (mg/1) 30 NHf N (mg/1) N1Z D.O. (mg/0 I�1 TSS (mg/1) 30 F. Col. -(/100ml) ZOO pH (SU) 6 'f fin, \.l A Aa4 Lf� �(re 9 a !e a r 1;n Y�f cfYc�� iU� f dR, uC C. Comments: f �.f (A-47 Request No.: 5237 _---------------- WASTELOAD ALLOCATION APPROVAL FORM ------------------- Facility Name: SAPPHIRE LAKE UTILITY COMPANY DEV. NO. 2 NPDES No.:-NCOO59439 Type_ of Waste: DOMESTIC Status: EXISTING RecezStream JAMES CREEK Wi....rl t�f '?t -.4.N., d-e_ ,:. C1"ass2`eation:.:, Subbasin: 031302. Drainage area: 0.410 sq mi County: TRANSYLVANIA Summer 701O: 0.60 cfs Regional Office: ASHEVILLE Winter 7Q1O: 0.40 cfs Requestor: LULA HARRIS Average flow: 1.60 cfs Date of Request: 4/26/B9 3OQ2- 0.70 cfs ,Quad: G7SW -------------------- RECOMMENDED EFFLUENT LIMITS------------------------- Wasteflow (mgd): 0.0049 BODS (mg/1): 30 .NH3N (mg/1): NR DO mg/1): NR TSS �mg/l): 30 Fecal coliform (#/IOOml): 200 phi ( su) : 6-9 Toxicity Testing Req.: (Existing Limits) ----^--------------=--------- MONITORING ------------------------- Upstream (Y/N): N Location: Downstream (Y/N): N Location: ----------------------------- COMMENTS --------------------------- FECAL COLIFORM LIMIT WAS KEPT AT 200 PER CONVERSATION BETWEEN FORREST WESTALL AND'STEVE ZOUFALY (MAY 2, 1989). ----------------------------=-------------------------------------- � C e _ Recommended by:. / � r.J=-� ---- , , - SL Date4Q---- Reviewed by Wech Support Supervisor: _ _ ___ __ _-____ Date': Regional S or: _ - __- �__--_ Date: fir} Water Qualtv Section Permits &.Engineering: Date: ------------ RETURN TO TECHNICAL SERVICES BY: � _� _ MAY 5 - 1089 kheville Regional Offic, Facility Status: (Please check one of the following) All monitoring data and sampling frequencies meet permit requirements (including weekly averages, if applicable) 1Z Compliant All monitoring data and sampling frequencies do NOT meet permit requirements Noncompliant The permittee shall report to the Director or the appropriate Regional Office any noncompliance that potentially threatens public health or the environment. Any information shall be provided orally within 24 hours from the tii;te the permittee became aware of the circumstances. A written submission shall also be provided within 5 days of the time the permittee becomes aware of the circumstances. If the facility is noncompliant, please attach a list of eatrrective actions being taken and a tinie-table for improvements to be made as required by Part 111.E.6 of the NPDES perinit. "I certify, under penalty of law, that this document and all attachments were prepared under my direction or sunei-yision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who managed the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations," Permittee (Please print or type) Signature of Permittee" x Gate (Required unless submitted electronically) P.O. Box 1407 Pisgah Forest, N.C. 28708 528-'q84-9772 ;,,L;, ,;, � ,,5/31;2022 Permittee Address Plume Nulnher e-mail address 'Permit I:.pir,urut ADDITIONAL CERTIFIED LABORATORIES Certified Laboratory (2) Certified Laboratory (3) Certified Laboratory (4) Certified Laboratory (5) PARAMETER COOTS Certification No. Certification No. Certification No. Certification No. Parameter Code assistance may be obtained by ;ailing the NPDES Unit at (919) M-6300 or by visiting- http:;/portal.ncderr.orghveb/wq/st>Yp/psi npde'appfc;rins, Use only units of measurement designated in the reporting, facility's NPDES pennit for reporting data. No Flow/Discharge From Site: ':heck this box. if no discharge occurs and, fts a :•welt. there are no data aP he entered for all of the parameters on the DMR ibr the entire monitoring period. xr ORC On Site?: ORC must vi:>it facility and document visitation orfacility a., regtiii*ed per i5A NCAC 8(:.0?04. xkie Signature of Permittee, lrsi fined by other than the ermiuce, then: the dele.a• --r . ,. _ b I ration of the si�.l.c.;�ry atn;ulritN mist be on file with the state per 15A NCAC 2B .0506(b)(2)(Ci). EFFLUENT NPDES PERMITNO. NCO059439 DISCHARGE NO. Oo / MONTH -Wa X YEAR Z o FACILITY NAME Sapphire Lakes 2 CLASS_— COUNTY Transylvania CERTIFIED LABORATORY (1) Environmental Testing Solutions (list additional laboratories on the backsidelpage 2 ofthis form) OPERATORINRESPONSIBLE CHARGE (ORC) Gary Norton GRADE ff CERTIECATIONNO. 21853 PERSON(S) COLLECTING SAMPLES Gary Norton / Richard McCrary ORC PHONE 828-553-2990 CHECK BOX IF ORC HAS CHANGED ® NO FLONV / DISCHARGE FRONT SITE Mail ORIGINAL and ONE COPY to: ATIMCENTRALFILF.S DIVISION OFWATERRESOURCES 1617i1'IAILSERVICECF.N ER RALEIGM NC 27699-1617 BY THIS SIGNATURE, I CERTIFY THATUM REPORTIS ACCURATEAND COIDIPIETE TOTHE BESTOFMY KNONLEDGE. 6-2z-/ II I III ___- • • �'BELOW iii����iiiiiiiii i[�►IfTi�i mom ,,, �a��►. ���i�r���iiiiiii ��i 950 �r 5 ice' D L mm Miii����iiw �_ - 6 Y'kb,7.� NMI miii FMre= 0 1111110%"� c #'iif. . M. J6'.T.fI'. P :• i EMMMEN MMMIM !►1.lir1,lJl���iiiiiiiiiii DWR Form MR-1 (08/05) Vu i1N[T Facility Status: (Please check one of the following) All monitoring data and sampling frequencies meet permit requirements (including weekly averages, if applicable) Compliant X All monitoring data and sampling frequencies do NOT meet permit requirements Noncompliant ' lJt The permittee shall report to the Director or the appropriate Regional Office any noncompliance that potentially If the facility is noncompliant, please attach a list of corrective actions being taken and a time -table for "I certify, under penalty of law, that this document and all attachments were prepared under my direction or A&D WATER SERVICES, INC Permittee (Please print or type) v Signature of Permittee*** I (Required unless submitted electronically) PO BOX 1407, PISGAH FOREST, NC 28768 8928-884-9537 admaint(ftitcom.net 2022 Permittee Address Phone Number e-mail address Permit Expiration Date ADDITIONAL CERTIFIED LABORATORIES Certified Laboratory (2) Certification No. Certified Laboratory (3) , Certification No. Certified Laboratory (4) Certification No. Certified Laboratory (5) Certification No. PARAMETER CODES Parameter Code assistance may be obtained by calling the NPDES Unit at (919) 733-5083 or by visiting the Use only units of measurement designated in the reporting facility's NPDES permit for reporting data. * No Flow/Discharge From Site: Check this box if no discharge occurs and, as a result, there are no data to be entered f6r all `of the parameters on the DMR for the entire monitoring period. xx ORC On Site?: -ORC-'inust visit facility and document visitation of facility as required per 15A NCAC 8G .0204. x*x Signature of Permittee: If signed by other than the permittee, then the delegation of the signatory authority must be on rlle wim me stare Der 1JA iNUAL; 215 EFFLUENT NPDES PERMIT NO NCO059439 DISCHARGE NO. 001 MONTH JUNE YEAR 2019 FACILITY NAME SAPPHIRE LAKES 2 i CLASS 1 COUNTY TRANSYLVANIA CERTIFIED LABORATORY (1) . E T S CERTIFICATION NO (2) NC600 (list additional laboratories on the backsidelpage 2 of this form) OPERATOR IN RESPONSIBLE CHARGE (ORC) William Wesley Royal GRADE 3 CERTIFICATION NO. 13471 PERSON(S) COLLECTING SAMPLES Wes Royal ORC PHONE 828-884-9537 CHECK BOX IF ORC HAS CHANGED X NO FLOW /DISCHARGE FROM SITE Mail ORIGINAL and ONE COPY to: ATTN: CENTRAL FILES DIVISION OF WATER QUALITY 1617 MAIL SERVICE CENTER RALEIGH, NC 27699-1617 (SIGNATURE OF I T R IN RESPONSIB CHARGE) BY THIS SIGNATURE,' CERTIFY THAT THIS REPOR S_ ACCURATE AND COMPLETE TO THE BEST OF MY KNOWLEDGE. 7/222019 DATE — ' • 1 1 / MonthlyLimit DWQ Form MR-1 (11/04 ) J Facility Status: (Please check one of the following) All monitoring data and sampling frequencies meet permit requirements (including weekly averages, if applicable) Compliant 0 All monitoring data and sampling frequencies do NOT meet permit requirements Noncompliant 0 The permittee shall report to the Director or the appropriate Regional Office any noncompliance that potentially If the facility is noncompliant, please attach a list of corrective actions being taken and a time -table for "I certify, under penalty of law, that this document and all attachments were prepared under my direction or A&D WATER SERVICES, INC Permittee (Please print or type) Signature of Permittee*** I (Required unless submitted electronically) PO BOX 1407, PISGAH FOREST, NC 28768 admaint(ftitcornmet 2022 Permittee Address Phone Number e-mail address Permit Expiration Date Certified Laboratory (2) Certified Laboratory (3) Certified Laboratory (4) Certified Laboratory (5) ADDITIONAL CERTIFIED LABORATORIES PARAMETER CODES Certification No. Certification No. Certification No. Certification No. Parameter Code assistance may be obtained by calling the NPDES Unit at (919) 733-5083 or by visiting the Use only units of measurement designated in the reporting facility's NPDES permit for reporting data. x No Flow/Discharge From Site: Check this box if no discharge occurs and, as a result, there are no data to be entered for all of the parameters on the DMR for the entire monitoring period. ** ORC On Site?: ORC must visit facility and document visitation of facility as required per 15A NCAC 8G .0204. ***Signature of Permittee: If signed by other than the permittee, then the delegation of the signatory authority must be on file with the state per 15A NCAC 2B .0506(b)(2)(D). EFFLUENT 1 NPDES PERMIT NO NCO059439 DISCHARGE NO. 001 MONTH JULY YEAR 2019 FACILITY NAME SAPPHIRE LAKES 2 CLASS 1 COUNTY TRANSYLVANIA CERTIFIED LABORATORY (I) E T S CERTIFICATION NO (2) NC600 (list additional laboratories on the backside/page 2 of this form) OPERATOR IN RESPONSIBLE CHARGE (ORC) William Wesley Royal GRADE 3 CERTIFICATION NO. 13471 PERSON(S) COLLECTING SAMPLES Wes Royal 0 ONE 828-884-9537 CHECK BOX IF ORC HAS CHANGED NO FLOW / DISCHARGE FROM SITE Mail ORIGINAL and ONE COPY to: ATTN: CENTRAL FH.ESZ�I�K78/26/2019 DIVISION OF WATER QUALITY (SIGNATUREkOF OPERATOR IN RESPONSIBLE CHARGE) \ DATE 1617 MAIL SERVICE CENTER BY THIS SIGNATURE, I CERTIFY THAT THIS REPORT IS RALEIGH NC 27699-1617 ACCURATE AND COMPLETE TO THE BEST OF MY KNOWLEDGE. jk II I III 1 II•II 11,1 II I II. I II I ®' It II ---_�- 111 11 , ®®®®®® ® ®®®® MonthlyLimit 1 1 1•` ■ I' 1 ��■� 1 1 1 1 ■■■■■■■ DWQ Forth MR-1 (11/04 ) U ars SEA 0 q 2C►9 EFFLUENT NPDES PERMIT NO NCO059439 DISCHARGE NO. 001 MONTH SEPT YEAR 2019 FACILITY NAME SAPPHIRE LAKES 2 CLASS 1 COUNTY TRANSYLVANIA CERTIFIED LABORATORY (1) E T S CERTIFICATION NO (2) NC600 (list additional laboratories on the backside/page 2 of this form) OPERATOR IN RESPONSIBLE CHARGE (ORC) William Wesley Royal GRADE 3 CERTIFICATION NO. 13471 PERSON(S) COLLECTING SAMPLES Wes Royal ORS ONE 828-884-9537 CHECK BOX IF ORC HAS CHANGED J NO FLOW / DISCHARGE FROM SITE Mail ORIGINAL and.ONE COPY to:�/ ATTN: CENTRAL FILES 10J23J2019 DIVISION OF WATER QUALITY (SIGNATURE OROPERATOMNIRPSPONSIBLE CHARGE) -----DATE 1617 MAH, SERVICE CENTER BY THIS SIGNATURE, I CERTIFY THAT THIS REPORT IS RALEIGH NC 27699-1617 ACCURATE AND COMPLETE TO THE BEST OF MY KNOWLEDGE. 50050 00010 004C FLOW F2 * EFF ❑ � 2 y DVF (] h u `3 q EA e 0 aF aV a 60 O � � tom• O 2 I0310 00610 00530 31616 1 00300 DISSOL ENTER PARAMETER CODE ABOVE VED OXYGE NAME AND UNITS BELOW O Z W W W a qP .a N �N �0+y0 z FWq O a U�• a y V V � I: , ©mom■■■® ■■■®��■■�■■�■■■■ DWQ Farts MR-1 (11104 ) mes D Nov 0 4 2019 �IJI V I�J�J�I]�L.JIVI 1 :J(1.:SSNGUNIT Facility Status: (Please check one of the following) All monitoring data and sampling frequencies meet permit requirements (including weekly averages, if applicable) Compliant X All monitoring data and sampling frequencies do NOT meet permit requirements Noncompliant 0 The permittee shall report to the Director or the appropriate Regional Office any noncompliance that potentially If the facility is noncompliant, please attach a list of corrective actions being taken and a time -table for "I certify, under penalty of law, that this document and all attachments were prepared under my direction or A&D WATER SERVICES, INC Permittee (Please print or type) Permittee*** Date (Required unless submitted electronically) PO BOX 1407, PISGAH FOREST, NC 28768 8928-884-9537 admaint@citcornmet 2022 Permittee Address Phone Number e-mail address Permit Expiration Date ADDITIONAL CERTIFIED LABORATORIES Certified Laboratory (2) Certification No. Certified Laboratory (3)•: Certification No. Certified Laboratory (4) Certification No. Certified Laboratory (5) Certification No. PARAMETER CODES Parameter Code assistance may be obtained by calling the NPDES Unit at (919) 733-5083"or by visiting the Use only units of measuremenf designated in the reporting facility's NPDES permit for reporting data. x No Flow/Discharge From Site: Check this box if no discharge occurs and, as a result, there are no data to be entered for all of the parameters on the DN M for the entire monitoring period. ** ORC On Site?: ORC must visit facility and document visitation of facility as required per 15A NCAC 8G .0204. *xx Signature of Permittee: If signed by other than the permittee, then the delegation of the signatory authority must be on file with the state Der 15A NUAC 2B A506 EFFLUENT NPDES PERMIT NO NCO059439 DISCHARGE NO. 001 MONTH OCTOBER YEAR 2019 FACILITY NAME SAPPHIRE LAKES 2 CLASS 1 COUNTY TRANSYLVANIA CERTIFIED LABORATORY (1) E T S CERTIFICATION NO (2) NC600 (list additional laboratories on the backside/page 2 of this form) OPERATOR IN RESPONSIBLE CHARGE (ORC) William Wesley Royal GRADE 3 CERTIFICATION NO. 13471 PERSON(S) COLLECTING SAMPLES Wes Royal OR HONE 828-884-9537 CHECK BOX IF ORC HAS CHANGED NO FLOW / DISCHARGE FROM SITE Mail ORIGINAL and ONE COPY to: JZ ATM: CENTRAL FILES 11/152019 DIVISION OF WATER QUALITY (SIGNATURE O OPERATOR IN KFSPONSIBLE C ) DATE 1617 MAIL SERVICE CENTER BY THIS SIGNATURE, I CERTIFY THAT THIS REPORT IS - RALEIGH NC 27699-1617 ACCURATE AND COMPLETE TO THE BEST OF MY KNOWLEDGE. 1111116-11IN1111111 O0 9 71777, E�i�®®®®® ®------ m� 11 ©mom■�■■■■■■�■■�■ram■■ a■ate■aa■e■a■■■■■■■ ®®®®®®®®®®® ® I I ■ I' I ���� I I I I I ■■■■■■■ DWQ Form MR-1 (11/04) r-"j j•�- • I�j ram' c H C 4 2CM Water ou,-,iii,,./ Rc.rijoi7al Operations �1shlMville Re-; ;;nal Office Facility Status: (Please check one of the following) All monitoring data and sampling frequencies meet permit requirements (including weekly averages, if applicable) Co�X All monitoring data and sampling frequencies do NOT meet permit requirements Noncompliant I The permittee' shall report to the Director or the appropriate Regional Office any noncompliance that potentially If the facility is noncompliant, please attach a list of corrective actions being taken and a time -table for "I certify, under penalty of law, that this document and all attachments were prepared under my direction or — - - A&D WATER SERVICES, INC Permittee (Please pr' t or type) Jz& Signature dfPermittee*** Date (Required unless submitted electronically) PO BOX 1407, PISGAH FOREST, NC 28768 8928-884-9537 admaint(ftitcom.net 2022 Permittee Address Phone Number e-mail address Permit Expiration Date Certified Laboratory (2) Certified Laboratory (3) Certified Laboratory (4) Certified Laboratory (5) ADDITIONAL CERTIFIED LABORATORIES PARAMETER CODES Certification No. Certification No. Certification No. Certification No. Parameter Code assistance may be obtained by calling the NPDES Unit at (919) 733-5083 or by visiting the Use only units of measurement designated in the reporting facility's NPDES permit for reporting data. * No Flow/Discharge From Site: Check this box if no discharge occurs and, as a result, there are no data to be entered for all of the parameters on the DMR for the entire monitoring period. xx ORC On Site?: ORC must visit facility and document visitation of facility as required per 15A NCAC 8G .0204. xx Signature of Permittee: If signed by other than the permittee, then the delegation of the signatory authority must be on file with the state per 1SA NUAU 215 EFFLUENT NPDES PERMIT NO NCO059439 DISCHARGE NO. 001 MONTH NOVEMBER YEAR 2019 FACILITY NAME SAPPHIRE LAKES 2 CLASS 1 COUNTY TRANSYLVANIA CERTIFIED LABORATORY (1) E T S CERTIFICATION NO (2) (list additional laboratories on the backside/page 2 of this form) OPERATOR IN RESPONSIBLE CHARGE (ORC) William Wesley Royal GRADE 3 u PERSON(S) COLLECTING SAMPLES Wes Royal ORC PHC CHECK BOX IF ORC HAS CHANGED Mail ORIGINAL and ONE COPY to: ATTN: CENTRAL FILES DIVISION OF WATER QUALITY (SIGNATURE OF OPERAT SP SE3LE CHARGE) 1617 MAIL SERVICE CENTER BY THIS SIGNATURE, I CERTIFY THAT THIS REPORT IS RALEIGH. NC 27699-1617 ACCURATE AND COMPLETE TO THE BEST OF MY KNOWLEDGE. NC600 ICATION NO. 13471 1 828-884-9537 / DISCHARGE FROM SITE 12/26/2019 DATE II I I11 1 II•IIoff1.1 II I - _ 1 OVED 11 1 1 MWIN-OXYGE © ■■■■■■■�■■■■■■�■mom■■■■® a®ate■ate■a■�®■®®®®® ■®ea®®a®■■■®■® DWQ Forth MR-1 (11/04 ) K Y JAN 0 6 2020 • J AN 0 2'C!-,) Facility Status: (Please check one of the following) All monitoring data and sampling frequencies meet permit requirements (including weekly averages, if applicable) Compliant - X All monitoring data and sampling frequencies do NOT meet permit requirements Noncompliant The permittee shall report to the Director or the appropriate Regional Office any noncompliance that potentially If the facility is noncompliant, please attach a list of corrective actions being taken and a time -table for "I certify, under penalty of law, that this document and all attachments were prepared under my direction or A&D WATER SERVICES, INC Permittee (Please print or type) (Required unless submitted electronically) PO BOX 1407, PISGAH FOREST, NC 28768 8928-884-9537 admaint@citcornmet 2022 Permittee Address Phone Number e-mail address Permit Expiration Date Certified Laboratory (2) Certified Laboratory (3) Certified Laboratory (4) Certified Laboratory (5) ADDITIONAL CERTIFIED LABORATORIES PARAMETER CODES Certification No. Certification No. Certification No. Certification No. Parameter Code assistance may be obtained by calling the NPDES Unit at (9.19)­733=5083 or by visiting the Use only units of measurement designated in the reporting facility's NPDES permit for reporting data. * No Flow/Discharge From Site: Check this box if no discharge occurs and, as a result, there are no data to be entered for all of the parameters on the DMR for the entire monitoring period. ** ORC On Site?: ORC must visit facility and document visitation of facility as required per 15A NCAC 8G .0204. *** Signature of Permittee: If signed by other than the permittee, then the delegation of the signatory authority must be on the with the state per 1SA NCAC Z13 EFFLUENT NPDES PERMIT NO NCO059439 FACILITY NAME SAPPHIRE LAKES 2 CERTIFIED LABORATORY (1) E T S (list additional laboratories on the backside/page 2 of this form) OPERATOR IN RESPONSIBLE CHARGE (ORC) William PERSON(S) COLLECTING SAMPLES Wei CHECK BOX IF ORC HAS CHANGED DISCHARGE NO. 001 CLASS CERTIFICATION NO (2) MONTH DECEMBER YEAR 2019 1 COUNTY TRANSYLVANIA NC600 GRADE 3 CERTIFICATION NO. 13471 ORC PHONE 828-884-9537 Mail ORIGINAL and ONE COPY to: 1 / ATM: CENTRAL I MES DIVISION OF WATER QUALITY (SIGNAWkE OF OPERATOR IN VSPONSIBLE CHARGE) 1617 RAL MAIL SERVICE CENTER BY THIS SIGNATURE, I CERTIFY THA S REPORT IS RALEIGA NC 27699-1617 ACCURATE AND COMPLETE TO THE BEST OF MY KNOWLEDGE. NO FLOW / DISCHARGE FROM SITE rXX 1/30/2020 DATE -I 1 �- 11 l, Mill IIIIII�IIIIIIsi;��lllll'i37�®®®®® 11 ®------ '-minthly ®®®®®®®®®®®®®® LimitI I ■, I, I ���� I. I I ■■■■■■■ DWQ Forth MR-1 (11104 ) F:r-P1N"= FEB 0 3 2020 ,\,�Q SECTION INFORPIIP:TION PROCESSING UNIT Facility Status: (Please check one of the following) All monitoring data and sampling frequencies meet permit requirements (including weekly averages, if applicable) Co�X All monitoring data and sampling frequencies do NOT meet permit requirements Noncompliant The permittee shall report to the Director or the appropriate Regional Office any noncompliance that potentially If the facility is noncompliant, please attach a list of corrective actions being taken and a time -table for "I certify, under penalty of law, that this document and all attachments were prepared under my direction or - - A&D•WATER SERVICES, INC Permittee (Please printgr type) (Required unless submitted electronically) PO BOX 1407, PISGAH FOREST, NC 28768 8928-884-9537 admaint@citcom.net 2022 Permittee Address - Phone Number e-mail address Permit Expiration Date Certified Laboratory (2) Certified Laboratory (3) Certified Laboratory (4) Certified Laboratory (5) ADDITIONAL CERTIFIED LABORATORIES PARAMETER CODES Certification No. Certification No. Certification No. Certification No. Parameter Code assistance may be obtained by calling the NPDES Unit at (919) 733-5083 or by visiting the Use only units of measurement designatedin the,reporting facility's NPDES permit for reporting data. * No Flow/Discharge From Site: Check this box if no discharge occurs and, as a result, there are no data to be entered for all of the parameters on the DMR for the entire monitoring period. x* ORC On Site?: ORC must visit facility and document visitation of facility as required per 15A NCAC 8G .0204. *** Signature of Permittee:' Ifsigned by other than the permittee, then the delegation of the signatory authority must be on file with the'state per I5A NCAC 2B .0506(b)(2)(D). EFFLUENT NPDES PERMIT NO NCO059439 DISCHARGE NO. 001 MONTH JANUARY YEAR 2020 FACILITY NAME SAPPHIRE LAKES 2 CLASS 1 COUNTY TRANSYLVANIA CERTIFIED LABORATORY (1) E T S CERTIFICATION NO (2) NC600 (list additional laboratories on the backside/page 2 of this form) OPERATOR IN RESPONSIBLE CHARGE (ORC) William Wesley Royal GRADE 3 CERTIFICATION NO. 13471 PERSON(S) COLLECTING SAMPLES Wes Royal RC PHONE 828-884-9537 CHECK BOX IF ORC HAS CHANGED NO FLOW /DISCHARGE FROM SITE Mail ORIGINAL and ONE COPY to:440�z(ATTN: CENTRAL FILES 2/2712020 DIVISION OF WATER QUALITY (SIGNATURE OF OPERATOR IN RESPONSIBL DATE LMAIISERVICE CENTER BY THIS SIGNATURE, I CERTIFY THAT THIS REPORT IS EIGH. NC 27699-1617 ACCURATE AND COMPLETE TO THE BEST OF MY KNOWLEDGE. = — /ISSOL 1 D ENTER PARAMETER CODEABOVE 1BELOW w awl 1111 13 �0nc=��®llllll®®®® II ®-1----- DWQ Forth MR-1 (11/04 ) O MES MAR 4 2020 MAR 0 c, 2020 Facility Status: (Please check one of the following) All monitoring data and sampling frequencies meet permit requirements (including weekly averages, if applicable) Co�X All monitoring data and sampling frequencies do NOT meet permit requirements Noncompliant 0 The permittee shall report to the Director or the appropriate Regional Office any noncompliance that potentially If the facility is noncompliant, please attach a list of corrective actions being taken and a time -table for "I certify, under penalty of law, that this document and all attachments were prepared under my direction or A&D WATER SERVICES. INC Permittee (Please print or 3/25/2020 Signature ofPermittee*** Date (Required unless submitted ele tropically) PO BOX 1407, PISGAH FOREST, NC 28768 8928-884-9537 admaint@citcom.net 2022 Permittee Address Phone Number e-mail address Permit Expiration Date ADDITIONAL CERTIFIED LABORATORIES Certified Laboratory (2) Certification No. Certified Laboratory (3) Certification No. Certified Laboratory (4) Certification No. Certified Laboratory (5) ,r ' •."; ; Certification No. PARAMETER CODES Parameter Code assistance may be obtained by calling the NPDES Unit at (919) 733-5083 or by visiting the Use only units of measurement designated in the reporting facility's NPDES permit for reporting data. x No Flow/Discharge From Site: Check this box if no discharge occurs and, as a result, there are no data to be entered for all of the parameters on the DMR for the entire monitoring period. ** ORC On Site?: ORC must visit facility and document visitation of facility as required per 15A NCAC 8G .0204. *** Signature of Permittee: If signed by other than the permittee, then the delegation of the signatory authority must be on file with the state per 15A NCAC 213 .0506(b)(2)(D). EFFLUENT ` NPDES PERMIT NO NCO059439 DISCHARGE NO. 001 MONTH FEBRUARY YEAR 2020 FACILITY NAME SAPPHIRE LAKES 2 CLASS 1 COUNTY TRANSYLVANIA CERTIFIED LABORATORY (1) E T S CERTIFICATION NO (2) NC600 (list additional laboratories on the backside/page 2 of this form) OPERATOR IN RESPONSIBLE CHARGE (ORC) William Wesley Royal GRADE 3 CERTIFICATION NO. 13471 PERSON(S) COLLECTING SAMPLES Wes Royal O"ONE 828-884-9537 CRECK BOX IF ORC HAS CHANGED J NO FLOW /DISCHARGE FROM SITE Mail ORIGINAL and ONE COPY to: ATTN: CENTRAL FILES /-(3/25/2020 DIVISION OF WATER QUALITY - (SIGNATURE OP -OPERATOR INRESPONSIBLE C - DATE 1617 MAIL SERVICE CENTER BY THIS SIGNATURE, I CERTIFY THAT THIS REPORT IS RALEIGH NC 27699-1617 ACCURATE AND COMPLETE TO THE BEST OF MY KNOWLEDGE. II IKIT, 1 I ------ _ 1ENTER PARAMETER11ABOVE - 1 , NAME 1 UNITS BELOW IIIIDIIOIIIli7r71a711111'T�IIIII�®®®®® II ®III---_-- ® ®®®■®®■®■_®®®®®®® m■■■■■■�■■■■■■�■■may■■■ ` � ®■■■■■■�■■■■■■�■���;� . ram■■ 1 a■a�■aa■a■a■■■■■■■ DWO Form MR-1 (11104 ) APR 0 6 2020 pWP, SECTION II"�EORP9,4TION PROCESR►AIr_ I Lrr r Facility Status: (Please check one of the following) All monitoring data and sampling frequencies meet permit requirements (including weekly averages, if applicable) Compliant 0 All monitoring data and sampling frequencies do NOT meet permit requirements Noncompliant 0 The permittee shall report to the Director or the appropriate Regional Office any noncompliance that potentially If the facility is noncompliant, please attach a list of corrective actions being taken and a time -table for "I certify, under penalty of law, that this document and all attachments were prepared under my direction or A&D WATER SERVICES, INC Permittee (Please print or type) Signature of Permittee*** Date (Required unless submitted electronically) PO BOX 1407, PISGAH FOREST, NC 28768 8928-884-9537 admaint(cDcitcom.net 2022 Permittee Address Phone Number e-mail address Permit Expiration Date ADDITIONAL CERTIFIED LABORATORIES Certified Laboratory (2) Certification No. Certified Laboratory (3) Certification No. Certified Laboratory (4) ` : ` Certification No. Certified Laboratory (5) Certification No. PARAMETER CODES Parameter Code assistance may be obtained by calling the NPDES Unit at (919) 733-5.083 or by visiting the Use only units of measurement designated in the reporting facility's NPDES permit for reporting data. * No Flow/Discharge From Site: Check this box if no discharge occurs and, as a result, there are no data to be entered for all of the parameters on the DMR for the entire monitoring period. ** ORC On Site?: ORC must visit facility and document visitation of facility as required per 15A NCAC 8G .0204. x** Signature of Permittee: If signed by other than the permittee, then the delegation of the signatory authority must be on tale with the state per 15A NC;AU 2B .U.)U6(b EFFLUENT NPDES PERMIT NO NCO059439 DISCHARGE NO. 001 MONTH MARCH YEAR 2020 FACILITY NAME SAPPHIRE LAKES 2 CLASS 1 COUNTY TRANSYLVANIA CERTIFIED LABORATORY (1) E T S CERTIFICATION NO (2) NC600 (list additional laboratories on the backside/page 2 of this form) OPERATOR IN RESPONSIBLE CHARGE (ORC) William Wesley Royal GRADE 3 CERTIFICATION NO. 13471 PERSON(S) COLLECTING SAMPLES Wes Royal ORC NE 828-884-9537 CHECK BOX IF ORC HAS CHANGED NO FLOW / DISCHARGE FROM SITE Mail ORIGINAL and ONE COPY to: ATTN: CENTRAL FILES 4/28/2020 DMSION OF WATER QUALITY (SIGNATURE OF UERAMR IN RESPONSIBLE C GE) DATE 1617 MAH. SERVICE CENTER BY THIS SIGNATURE, I CERTIFY THAT THIS REPORT IS RALEIGH NC 27699-1617 ACCURATE AND COMPLETE TO THE BEST OF MY KNOWLE GE. II I 111 I I111 II,I II I I1I II I ®` ' 11 II ------ _ - _ 1ISSOL 1 1 ENTER PARAMETER CODEI NAME 1 1 I.'�,`1.��'�■- I..Y� Imlm111lll�0®IIIII®®®�* e®®®®®ems®o��������I'� I a■a�■aa■e■a■■■■■■■ I, ®®®®®®®®®®®®®® I I ■ � I1 ���� I I . I I ■■■■■_■ DWO Form MR-1 (11104 ) MAY 18 2020 DWR SECTION INFORMATION PROCESSING UNIT Water Pollution Control System Opera'®>z- Designation Form WPCSOCC NCAC(155An8,.GA201 Permittee Owner/Officer Name:. � Zz /,AV) Mailing Address: v �A5�� City: f %�jtC% States," (— Zip:'- Phone Email address:r�'} Signat q Date: ............................................................. .Facility Name: �`/� Permit#: 41600S`7 `��� 6 SUBMIT A SEPARATE FORM FOR EACH TYPE SYSTEM! Facility Type/Gradet Biological WWTP Surface Irrigation .Physical/Chemical Land Application Collection System ................................................................................... Operator in Responsible Charge (ORC), Print Pull Name: _ C�2r s� eyrrr�'s /1/ai 7a Certificate Type /Grade./Number: 1 f's 3 Work Phone #': S' $2 8 ), SS3- p 90 Signature: Date: S -2f —1e-1- "I'certify that I agree to my deli anon as the Operator irr Responsible Charge for the facility noted. I understand and will abide by the rules and regulations pertaining to the responsibilities of the ORC as set forth in 15A NCAC. 08G .0204 and failing, to.do so can result in Disciplinary Actions 'by'the Watei-Pollntion Control System Operators Certification Commission" .............................................................................................................................................. Back -Up Operator in Responsible Charge (Bt ORC) 'PrintFull Name:®,s�,� 4 _ ,:C),/1,6 .> Certificate Type / .Grade / Number:. Work Phone `I certify that I agree to my designation as: a Back-up Operator in,Responsible Charge for the facilitynoted. I understand and will abide by the rules, and regulations pertaining to the responsibilities of the BU ORC as set forth in 15A NCAC`08G .0205 and failing -to do so_ eau'result in Disciplinary Actions by Water Pollution ControlSystem Operators Certification Commission." .. ..................................... . . Mail, fax or email Me WPCSOCC 1618 Mail Service Center, Raleigh, NC 27699-1618 Fax:, 919.8®7.6492 original to: 4-r. N cei adhtialir cd�i Mail or fax a copy M the Asheville Fayetteville Mooresville appropriate Regional Office:, 2090 US Hwy 70 225 Green St 610'E Center Ave Swannanoa 28778 Suite 7I4 Suite.301 Fax: 828.209.7043 Fayetteville.28301-5045 Mooresville 281.15. Phone: 828.296.4506 Fax: '910'486.0707 Fax: 704.663.6040 'Phone:910.433.3300 Phone:704.663.1699 Washington Wilmington Winston-Salem 943 Washington Sq Mall 127 Cardinal -Dr 5.85 Waughtown :St Washington27889 Wahhington 28405-2845 Winston-Salem 27107 Fax:25.2.946.9215 Fax:910350.2018 F" 336.771.4631 Phone:.252.946.6481 Phone:910.796.7215 Phone:336.71IS606 Raleigh 3800 Barrett Dr Raleigh 27669 Fax: 019.571.4718 Phone:419.791.4200 Revised 02-2013 VA North Carolina Department of Environment and Pat McCrory Governor June 30, 2014 Audrey Deaver A&D Water Service Inc PO Box 1407 Pisgah Forest NC 28768 Natural Resources John E. Skvarla, III Secretary SUBJECT: Compliance Evaluation Inspection Sapphire Lakes WWTP #2 Permit No: NCO059439 Transylvania County Dear Mr. Deaver: On May 28, 2014, I conducted a compliance evaluation inspection on the Sapphire Lakes WWTP #2. I would like to thank you for your assistance in this inspection. The facility was found to be in compliance with permit NC0059439. Please refer to the enclosed inspection report for additional observations and comments. If you or your staff have any questions, please call me at: 296-4500. Sincerely, Katherine H Jimison Chemistry Technician III Asheville Regional Office Enclosure cc 17-Central Files -Basement Ashevil`leF'fes� Water Quality Regional Operations — Asheville Regional Office 2090 U.S. Highway 70, Swannanoa, North Carolina 28778 Phone: 828-2964500 FAX: 828-299-7043 Internet: http://portal.ncdenr.org/web/wq An Equal Opportunity 1 Affirmative Action Employer G:IWRIWQ1TransylvanialWastewateAMinorslSapphire Lakes WWTP #2 59439\59439 CEI 2014.doc I A- United States Environmental Protection Agency FFE Form Approved. Washington, D.C.20460 OMB No. 2040-0057 ` Water Compliance Inspection Report Approval expires B-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 1 2 15 1 3 I NCO059439 I11 12 14/05/28 17 18 L C( 19 Li 201 I 21I_I11 I I I I I I II I I 1 I I I I I I I I I I I I I I I I I I I I II I I I I I f6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------- --Reserved----------- 671 70 [,J 71 J72 L 73 I 74 7.51 I I I I I 80 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 12:05PM 14/05/28 12/09/01 Sapphire Lakes Plant WWfP #2 1600 US Hwy 64 W Exit Time/Date Permit Expiration Date Sapphire NC 28774 12:30PM 14/05/28 17/08/31 Name(s) of Onsite Representative(s)rritles(s)/Phone and Fax Number(s) Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Audrey Deaver,PO Box 1407 Pisgah Forest NC 28768//882-884-9772/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) ® Permit ® Operations & Maintenance ® Facility Site Review Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Kathy Jimison ARO WQ//828-296-4500/ % Z ^`� / Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers j Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# NPDES yr/mo/day Inspection Type 31 NCO059439 �11 12 14/05/28 17 18 ICI Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as neudssaj Mr. Aubrey Deaver assisted in this inspection. Some sections of the lattice fencing are gone. The fencing needs to be repaired or replaced to prevent access by unauthorized personnel. The facility appears to be operated and maintained well. Page# Permit: NCO059439 j. !r±ction Date: 05/28/2014 Owner -Facility; Sapphire Lakes Plant WWTP #2 Inspection Type: Compliance Evaluation Operations & Wkintenance Is the plant generally clean with acceptable housekeeping? Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Permit (If the present permit expires in 6 months or less). Has the permittee submitted a new application? Is the facility as described in the permit? # Are there any special conditions for the permit? Is access to the plant site restricted to the general public? Is the inspector granted access to all areas for inspection? Yes No NA NE 11 ❑ ❑ ❑ ❑ ❑ ® ❑ Yes No NA NE ❑ ❑ ® ❑ BE ❑ ❑ ❑ ❑ ® ❑ ❑ ❑ ® ❑ ❑ ®❑ ❑ ❑ Comment: Some sections of the lattice fencing are gone. The fencing should be repaired and or replaced to prevent access by unauthorized personnel. Sand Filters (Low rate) Yes No NA NE (If pumps are used) Is an audible and visible alarm Present and operational? ❑ ❑ ® ❑ Is the distribution box level and watertight? ❑ ❑ ® ❑ Is sand filter free of ponding? M ❑ ❑ ❑ Is the sand filter effluent re -circulated at a valid ratio? ❑ ❑ ® ❑ # Is the sand filter surface free of algae or excessive vegetation? ® ❑ ❑ ❑ # Is the sand filter effluent re -circulated at a valid ratio? (Approximately 3 to 1) ❑ ❑ ® ❑ Comment: Disinfection -Tablet Yes No NA NE Are tablet chlorinators operational? ® ❑ ❑ ❑ Are the tablets the proper size and type? ® ❑ ❑ ❑ Number of tubes in use? 2 Is the level of chlorine residual acceptable? ❑ ❑ ❑ Is the contact chamber free of growth, or sludge buildup? ® ❑ ❑ ❑ Is there chlorine residual prior to de -chlorination? ❑ ❑ ❑ Comment: There was no flow at the time of this inspection. De -chlorination Yes No NA NE Page# 3 I Permit: NCO059439 Inspection Date: 05/28/2014 Owner - Facility: Sapphire Lakes Plant WWTP #2 ` Insoection Tvoe: Compliance Evaluation De -chlorination Type of system ? Is the feed ratio proportional to chlorine amount (1 to 1)? Is storage appropriate for cylinders? # Is de -chlorination substance stored away from chlorine containers? Comment: Are the tablets the proper size and type? Are tablet de -chlorinators operational? Number of tubes in use? Comment: A stepped aerator is used for dechlorination. Yes No NA NE Other ❑ ❑ W ❑ ❑ ❑ ® ❑ ❑ ❑ ® ❑ ❑ ❑ ® ❑ ❑ ❑ ® ❑ Page# 4 WaterResources ENVIRONMENTAL QUALITY Patty Carland A&D Water Service Inc 117 Kira Ln Hendersonville, NC 28739 Division ai 4�i,cr Resources SEP 1 2 2017 Water Quality Regional Operations Asheville Regional Office ____-� September 11, 2017 Subject: Permit Renewal Application No. NCO059439 Sapphire Lakes Plant WWTP #2 Transylvania County Dear Applicant: ROY COOPER Cowernar MICHAEL S. REGAN Secretary S. JAY ZIMMERMAN Director The Water Quality Permitting Section acknowledges the March 31, 2017 receipt of your permit renewal application and supporting documentation. Your application will be assigned to a permit writer within the Section's NPDES WW permitting branch. Per G.S. 150E-3 your current permit does not expire until permit decision on the application is made. Continuation of the current permit is contingent on timely and sufficient application for renewal of the current permit. The permit writer will contact you if additional information is required to complete your permit renewal. Please respond in a timely manner to requests for additional information necessary to allow a complete review of the application and renewal of the permit. Information regarding the status of your.renewal application can be found online using the Department of Environmental Quality's Environmental Application Tracker at: https://deg. nc.gov/permits-regulations/permit-quidance/environmental-application-tracker If you have any additional questions about the permit, please contact the primary reviewer of the application using the links available within the Application Tracker. Sinccennr��ely J ow Wren Thedfor Administrative Assistant Water Quality Permitting Section cc: Central Files 111A00 iC)' ec: WQPS .Laserfiche File w/application State of North Carolina I Environmental Quality I Water Resources 1617 Mail Service Center I Raleigh, North Carolina 27699-1617 919-807-6300 NPDES APPLICATION - FORM D ately-owned treatment systems treating 1009/o domestic wastewaters <1.0 MGD Mail the complete application to: N. C. DENR / Division of Water Quality / NPDES Unit 1617 Mail Service Center, Raleigh, NC 27699-1617 "DES Permit C0059439 If you are completing this form in computer use the TAB key or the up - down arrows to move from one ,field to the next. To check the boxes, click your mouse on top of the box OtherUASe, please print or type. I. Contact Information: Owner Mame Facility Name Mailing Address City State / Zip Code Telephone Number Fax Number e-mail Address A & D Water Service, Inc. Sapphire Lakes WWTP #2 P.O. Box 1407 Pisgah Forest N.C. 28768 (828) 884-9772 (828) 884-8632 admaint@citcom.net 2. Location of facility producing discharge: --_-Check-here-if-same-address-as-above n--------_...- .------.._._..--�- --- --.-----�-_. Street Address or State Road Off US 64 at Sapphire Lakes Subdivision City State / Zip Code County Sapphire N. C. 28774 Transylvania 3. Operator Information: Name of the firm, public organization or other entity that operates the facility. (Note that this is not referring to the Operator in Responsible Charge or ORC) Name A & D Water Service, Inc. Mailing Address P. O. Box 1407 City Pisgah Forest State / Zip Code N. C. 28768 Telephone Number (828) 884-9772 Fax Number (828) 884-8632 e-mail Address admaint@citcom.net Division of "'ater Resources 1 of3 SEP 1 2 2017 Form-D 11/12 Water OUality Regional Operations 'i'vipe Renio-1 Office NPDES APPLICATION - FORM D tely-owned treatment systems treating 100% domestic wastewaters <1.0 MGD i of wastewater: Facility Generating Wastewater(check all that applyr Industrial ❑ Number of Employees Commercial ❑ Number of Employees Residential X Number of Homes g School ❑ Number of Students/Staff Other ❑ Explain: Describe the source(s) of wastewater (example: subdivision, mobile home park, shopping centers, restaurants, -etc.): Residential Condos Number of persons served: 16 5. Type of collection system X Separate (sanitary sewer only) ❑ Combined (storm sewer and sanitary sewer) 6. Outfall Information: Number of separate discharge points 1 Outfall Identification numbers) 001 Is the out fall equipped with a diffuser? X Yes ❑ No 7. Name of receiving stream(s) (NEW anplicarnts• provide a map shouting the exact location of each outfallf: James Creek 8. Frequency of Discharge: X Continuous ❑ Intermittent If intermittent: Days per week discharge occurs: Duration• 9. Describe the treatment system List all installed components, including capacities, provide design removal for BOD, TSS, nitrogen and phosphorus. If the space provided is not sufficient, attach the description of the treatment system in a separate sheet o f paper. Septic tank sank filter, chlorination, dechlorination and step aeration 2of3 Form-D 11112 NPDES APPLICATION - FORM D Itely-owned treatment systems treating 100'/o domestic wastewaters <1.0 MGD rmation: Treatment Plant Design flow 0.005 MGD Annual Average daily flow 0.000 MGD (for the previous 3 years) Maximum daily flow 0.000 MGD (for the previous 3 years) 1 L Is this facility located on Indian country? ❑ Yes X No 12. Effluent Data 11f W &EPLICANTS: Provide data for the parameters listed. Fecal Coliform, Temperature and pH shall be grab samples, for all otherparameters 24-hour composite sampling shall be used. If more than one analysis is reported, report daily maximum and monthly average. If only one analysis is reported, report as daily maximum. RENEWAL APPLICANTS• Provide the highest single reading the past 36 months or ammeters currentl in our erm� Mark Maximum) and Monthly � g Average over Parameter Icy Monthly Units of Maximum Avery a Measurement Bio h c emical O$ygen Demand (BODs) N/A N/A / mg/1 Fecal Coliform N/A N/A / 100 ml Total Suspended Solids N/A N/A Temperature (Summer) N/A N/A m g/1 Temperature (Winter) N/A N/A C pH N/A N/A C su 13. List all permits, construction approvals and/or applications: Type Permit Number Type Permit Number Hazardous Waste (RCRA) NESHAPS (CAA) UIC (SDWA) Ocean Dumping in g (MPRSA) NPDES NCO059439 Dredge or fill (Section 404 or CWA) PSD (CAA) Other Non -attainment program (CAA) 14. APPLICANT CERTIFICATION I certify that I am familiar with the information contained in the application and that to the best of my knowledge and belief such information is true, complete, and accurate. Aubrey Deaver President Fruited name of Person Sigru Title Signature Applicant North Carolina General Statute 143-215.6 (b)(2) states: Any person who knowingly makes any false statement representation, or certification in any application, record, report, plan, or other document files or required to be maintained under Article 21 or regulations of the Environmental Management' Commission implementing that Article, or who falsifies, tampers with, or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article. shall tx- glftty of a misdemeanor punishable by a fine not to exceed $25,W0, or by Imprisonment not to exceed six months, or by both. (18 U.S.C. Section 1001 provides a punishment by a fine of not more than $25,000 or imprisonment not more than 5 years, or both, for a similar offense.) 3of3 Form-0 11/12 Water Resources ENVIRONMENTAL OUALITY Mr. Aubrey Deaver, President A&D Water Services, Inc. PO Box 1407 Pisgah Forest, NC 28768 Dear Mr. Deaver: March 27, 2017 ROY COOPER Governor MICHAEL S. REGAN Secretory S. JAY ZIMMERMAN Director OWI� APR�5n Water Quality Re Subject: Permit Renewal I rn 9Q R S io a p cl Application No. NCO059439 e Sapphine Lake WWTP #2- Transylvania County The Water Quality Permitting Section acknowledges receipt of your permit application and supporting documentation received on March 27, 2017. The primary reviewer for this renewal application is Sarah Phillips. The primary reviewer will review your application, and she will contact you if additional information is required to complete your permit renewal. Per G.S. 150B-3 your current permit does not expire until permit decision on the application is made. Continuation of the current permit is contingent on timely and sufficient application for renewal of the current permit. Please respond in a timely manner to requests for additional information necessary to complete the permit application. If you have any additional questions concerning renewal of the subject permit, please contact Sarah Phillips at 919-807-6479 or Sarah.Phillips@ncdenr.gov. Sincerely, ?A" %`ie*vd Wren Thedford Wastewater Branch cc: Central Files ZDES =X' egional A lice State of North Carolina I Environmental Quality I Water Resources 1617 Mail Service Center I Raleigh, North Carolina 27699-1617 919-807-6300 RECEIVED Division of Water Resources APR 1 2 2017 Water Quality Regional opematiorls Asheville Regional Office NPDES APPLICATION - FORM D caned treatment systems treating 100% domestic wastewaters <1.0 MGD Mail the complete application to: N. C. DENR / Division of Water Quality / NPDES Unit 1617 Mail Service Center, Raleigh, NC 27699-1617 NPDES Permit C0059439 If you are completing this form in computer use the TAB key or the up - down arrows to move from one field to the next. To check the boxes, click your mouse on top of the box. Otherwise, please print or type. 1. Contact Information: Owner Name A & D Water Service, Inc. Facility Name Sapphire Lakes WWTP #2 Mailing Address P.O. Box 1407 R&EIV DWR Eta �tl City Pisgah Forest R 2 7 2017 State /Zip Code N.C. 28768 !"Maz Quality Telephone Number (828) 884-9772 P'e iftingSereti011 Fax Number (828) 884-8632 e-mail Address admaint@citcom.net 2. Location of facility producing discharge: Check here if same address as above ❑ Street Address or State Road Off US 64 at Sapphire Lakes Subdivision City Sapphire State / Zip Code N. C. 28774 County Transylvania 3. Operator Information: Name of the firm, public organization or other entity that operates the facility. (Note that this is not referring to the Operator in Responsible Charge or ORC) Name A & D Water Service, Inc. Mailing Address P. O. Box 1407 City Pisgah Forest State / Zip Code N. C. 28768 Telephone Number (828) 884-9772 Fax Number (828) 884-8632 e-mail Address admaint@citcom.net 1 of 3 Form-D 11/12 NPDES APPLICATION - FORM D owned treatment systems treating 100% domestic wastewaters <1.0 MGD 10. Flow Information: Treatment Plant Design flow 0.005 MGD Annual Average daily flow 0.000 MGD (for the previous 3 years) Maximum daily flow 0.000 MGD (for the previous 3 years) 11. Is this facility located on Indian country? ❑ Yes X No 12. Effluent Data NEW APPLICANTS: Provide data for the parameters listed. Fecal Coliform, Temperature and pH shall be grab samples, for all other parameters 24-hour composite sampling shall be used. If more than one analysis is reported, report daily maximum and monthly average. If only one analysis is reported, report as daily maximum. RENEWAL APPLICANTS: Provide the highest single reading (Daily Maximum) and Monthly Average over the past 36 months for parameters currently in your permit. Mark other parameters 'NIA". Parameter Daily Maximum Monthly Average Units of Measurement Biochemical Oxygen Demand (SODS) N/A N/A mg/l Fecal Coliform N/A N/A / 100 ml Total Suspended Solids N/A N/A mg/1 Temperature (Summer) N/A N/A C Temperature (Winter) N/A N/A C pH N/A N/A su 13. List all permits, construction approvals and/or applications: Type Permit Number Type Hazardous Waste (RCRA) UIC (SDWA) NPDES PSD (CAA) Non -attainment program (CAA) NCO059439 14. APPLICANT CERTIFICATION NESHAPS (CAA) Ocean Dumping (MPRSA) Dredge or fill (Section 404 or CWA) Other Permit Number I certify that I am familiar with the information contained in the application and that to the best of my knowledge and belief such information is true, complete, and accurate. Aubrey Deaver President Printed name of Person Sianin-e Title Signature of Applicant North Carolina General Statute 143-215.6 (b)(2) states: Any person who knowingly makes any false statement representation, or certification in any application, record, report, plan, or other document files or required to be maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, or who falsifies, tampers with, or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, shall be guilty of a misdemeanor punishable by a fine not to exceed $25,000, or by imprisonment not to exceed six months, or by both. (18 U.S.C. Section 1001 provides a punishment by a fine of not more than $25,000 or imprisonment not more than 5 years, or both, for a similar offense.) 3of3 Form-D 11/12 NPDES APPLICATION - FORM D caned treatment systems treating 100% domestic wastewaters <1.0 MGD 4. Description of wastewater: Facility Generating Wastewater(check all that apply): Industrial ❑ Number of Employees Commercial ❑ Number of Employees Residential X Number of Homes 8 School ❑ Number of Students/Staff Other ❑ Explain: Describe the source(s) of wastewater (example: subdivision, mobile home park, shopping centers, restaurants, etc.): Residential Condos Number of persons served: 16 5. Type of collection system X Separate (sanitary sewer only) ❑ Combined (storm sewer and sanitary sewer) 6. Outfall Information: Number of separate discharge points 1 Outfall Identification number(s) 001 Is the outfall equipped with a diffuser? X Yes ❑ No 7. Name of receiving stream(s) (NEW applicants: Provide a map showing the exact location of each outfall): James Creek 8. Frequency of Discharge: X Continuous ❑ Intermittent If intermittent: Days per week discharge occurs: Duration: _ 9. Describe the treatment system List all installed components, including capacities, provide design removal for BOD, TSS, nitrogen and phosphorus. If the space provided is not sufficient, attach the description of the treatment system in a separate sheet of paper. Septic tank sank filter, chlorination, dechlorination and step aeration 2of3 Form-D 11/12 NC®ENR North Carolina Department of Environment and Natural Resources Beverly Eaves Perdue Governor Mr. Aubrey Deaver A & D Water Service, Inc. P. O. Box 1407 Pisgah Forest, NC 28768 Division of Water Quality Charles Wakild, P.E. Dee Freeman Director Secretary August 15, 2012 Subject: Issuance of NPDES Permit NCO05943 9 A & D Water Service, Inc. - Sapphire Lakes WWTP #2 Transylvania County Dear Mr. Deaver: Division personnel have reviewed and approved your application for renewal of the subject permit. Accordingly, we are forwarding the attached NPDES discharge permit. This permit is issued pursuant to the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement between North Carolina and the U.S. Environmental Protection Agency dated October 15, 2007 (or as subsequently amended). This final permit includes no significant changes from the draft permit sent to you on June 13, 2012. If any parts, measurement frequencies or sampling requirements contained in this permit are unacceptable to you, you have the right to an adjudicatory hearing upon written request within thirty (30) days following receipt of this letter. This request must be in the form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings (6714 Mail Service Center, Raleigh, North Carolina 27699-6714). Unless such demand is made, this decision shall be final and binding. Please note that this permit is not transferable except after notice to the Division. The Division may require modification or revocation and reissuance of the permit. This permit does not affect the legal requirements to obtain other permits which may be required by the Division of Water Quality or permits required. by the Division of Land Resources, the Coastal Area Management Act or any other Federal or Local governmental permit that may be required. If you have any questions concerning this permit, please contact Bob Sledge at telephone number (919) 807- 6398, or via e-mail at bob.sledge@ncdenr.g6v. lam. ..__..... _ e..''.�" •r .. 'Y.... .. .. rQ Takild, P.E. SE 1 1 2 cc: Central Files__ Asheville .Regional Office/Surface Water Protection_Section? NPDES File 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Location: 512 N. Salisbury St. Raleigh; North Carolina 27604 Phone: 919-807-6300 \ FAX: 919-807-6492 Internet: www.ncwaterquality.org An Equal Opportunity \ Affirmative Action Employer IT At�c.J1LLne . NorthCarolina Nq%wICif Permit NC0059439 STATE OF NORTH CAROLINA ,PARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY PERMIT TO DISCHARGE WASTEWATER UNDER THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provisions of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, A & D Water Service, Inc. is hereby authorized to discharge wastewater from a facility located at the Sapphire Lakes WWTP #2 Off US Highway 64 at Sapphire Near Round Top Mountain Transylvania County to receiving waters designated as James Creek in the Savannah River Basin in accordance with effluent limitations, monitoring requirements, and other conditions set forth in Parts I, II, III and IV hereof. This permit shall become effective September 1, 2012. This permit and authorization to discharge shall expire at midnight on August 31, 2017. Signed this day August 15, 2012. 2es Wakild, P.E., Director -Division of Water Quality By Authority of the Environmental Management Commission Permit NC SUPPLEMENT TO PERMIT COVER SHEET All previous NPDES Permits issued tOAMS facility, whether for operation or discharge are huiuoy revoked. As of this permit issuance, any previously issued permit bearing this number is no longer effective. Therefore, the exclusive authority to operate and discharge from this facility arises under the permit conditions, requirements, terms, and provisions included herein. A & D Water Service, Inc. is hereby authorized to: 1. Continue to operate an existing 0.0049 MGD wastewater treatment system with the following components: ♦ 1000 gallon dosing tank with siphon bell ♦ Distribution manifold ♦ 25' x 30' Surface sand filter ♦ Tablet chlorination ♦ Chlorine contact chamber ♦ Tablet dechlorination ♦ Cascade aeration The facility is located near Round Top Mountain at Sapphire Lakes Utility Company Plant #2 off US Highway 64 at Sapphire in Transylvania County. 2. Discharge from said treatment works at the location specified on the attached map into James Creek, classified C+ waters in the Savannah River Basin. Pentit NC0059439 MR- /l VVIXv M- Point _ r Itb\ lit, d �:Ij \j �, �f,,,; ' f f " �`� , 1 ' T ;4 d (� 3 l /� .t� � �� l/ /� ! `/i\.-.� � ���,✓J f� �--� �� r �: _f \\�.��_J � ��f) �{� L `l!'/' ~--J ti + {/ 0 A&D Water Service, Inc.t- Sapphire Lakes WWTP #2 Facility'`t Latitude: 35106'33" Stream Class: C Location . 54 Longitude:82°58'35" Subbasin:031302 Quad # G7SW Receiving Stream: James Creek NPDES Permit NCO059439 Trans Ivania Count Permit NC A. (L) EFFLUENT LIMITATIONS AND' MONITORING REQUIREMENTS - FINAI During the period beginning on the effective date of this permit and lasting until expiration, the Permittee is authorized to discharge from outfa11001. Such discharges shall be limited and mo.111LUI%,u by the Permittee as specified below: EFFLUENT CHARACTERISTICS LIMITS MONITORING REQUIREMENTS Parameter Code Monthly Average Daily Maximum Measurement Frequency Sample Type Sample Location Flow 50050 0.0049 MGD Weekly Instantaneous Influent or Effluent BOD, 5-day (20°C) C0310 30.0 mg/L 45.0 ing/L 2/Month Grab Effluent Total Suspended Solids C0530 30.0 mg/L 45.0 mg/L 2/Month Grab Effluent NHs as N C0610 Monthly Grab Effluent Fecal Coliform 31616 (geometric mean 200/100 ml 400/100 ml 2/Month Grab Effluent Total Residual Chlorines 50060 28 Ng/L 2/Week Grab Effluent Temperature (°C) 00010 Weekly Grab Effluent pH2 O0400 2/Month Grab Effluent Footnotes: 1. The Division shall consider all effluent TRC values reported below 50 µg/L to be in compliance with the permit. However, the Permittee shall continue to record and submit all values reported by a North Carolina certified laboratory (including field certified), even if these values fall below 50 n/L. 2. The pH shall not be less than 6.0 standard units nor greater than 9.0 standard units. There shall .be no discharge of floating solids or visible foam in other than trace amounts. )ES Permit Standard Conditions - Page 1 of 18 PART II STANDARD CONDITIONS FOR NPDES PERMITS Section A. Definitions 2/Month Samples are collected twice per month with at least ten calendar days between sampling events. These samples shall be representative of the wastewater discharged during the sample period. 3/Week Samples are collected three times per week on three separate calendar days. These samples shall be representative of the wastewater discharged during the sample period. Act or "the Act' The Federal Water Pollution Control Act, also known as the Clean Water Act (CWA), as amended, 33 USC 1251, et. seq. Annual Average The arithmetic mean of all "daily discharges" of a pollutant measured during the calendar year. In the case of fecal coliform, the geometric mean of such discharges. Arithmetic Mean The summation of the individual values divided by the number of individual values. Bypass The known diversion of waste streams from any portion of a treatment facility including the collection system, which is not a designed or established or operating mode for the facility. Calendar Day The period from midnight of one day until midnight of the next day. However, for purposes of this permit, any consecutive 24-hour period that reasonably represents the calendar day may be used for sampling. Calendar Week The period from Sunday through the following Saturday. Calendar Quarter One of the following distinct periods: January through March, April through June, July through September, and October through December. Composite Sample A sample collected over a 24-hour period by continuous sampling or combining grab samples of at least 100 mL in such a manner as to result in a total sample representative of the wastewater discharge during the sample period. The Director may designate the most appropriate method (specific number and size of aliquots necessary, the time interval between grab samples, etc.) on a case -by -case basis. Samples may be collected manually or automatically. Composite samples may be obtained by the following methods: (1) Continuous: a single, continuous sample collected over a 24-hour period proportional to the rate of flow. (2) Constant time/variable volume: a series of grab samples collected at equal time intervals over a 24 hour period of discharge and combined proportional to the rate of flow measured at the time of individual sample collection, or (3) Variable time/constant volume: a series of grab samples of equal volume collected over a 24 hour period with the time intervals between samples determined by a preset number of gallons passing the sampling point. Flow measurement between sample intervals shall be determined by use of a flow recorder and totalizer, and the preset gallon interval between sample collection fixed at no greater than 1/24 of the expected total daily flow at the treatment system, or Version 1110912011 NPDES Permit Standard C4, Page (4) Constant time/constant volume: a series of grab samples of equal volume collected over a 24-hour period at a constant time interval. Use of this method requires prior approval by the Director. This method may only be used in situations where effluent flow rates vary less than 15 percent. The following restrictions also apply: ➢ Influent and effluent grab samples shall be of equal size and of no less than 100 milliliters ➢ Influent samples shall not be collected more than once per hour. ➢ Permittees with wastewater treatment systems whose detention time < 24 hours shall collect effluent grab samples at intervals of no greater than 20 minutes apart during any 24-hour period. ➢ Permittees with wastewater treatment systems whose detention time exceeds 24 hours shall collect effluent grab samples at least every six hours; there must be a minimum of four samples during a 24-hour sampling period. Continuous flow measurement Flow monitoring that occurs without interruption throughout the operating hours of the facility. Flow shall be monitored continually except for the infrequent times when there may be no flow or for infrequent maintenance activities on the flow device. Daily Discharge The discharge of a pollutant measured during a calendar day or any 24-hour period that reasonably represents the calendar day for purposes of sampling. For pollutants measured in units of mass, the "daily discharge" is calculated as the total mass of the pollutant discharged over the day. For pollutants expressed in other units of measurement, the "daily discharge" is calculated as the average measurement of the pollutant over the day. (40 CFR 122.2; see also "Composite Sample," above.) Daily Maximum The highest "daily discharge" during the calendar month. Daily Sampling Parameters requiring daily sampling shall be sampled 5 out of every 7 days per week unless otherwise specified in the permit. Sampling shall be conducted on weekdays except where holidays or other disruptions of normal operations prevent weekday sampling. If sampling is required for all seven days of the week for any permit parameter(s), that requirement will be so noted on the Effluent Limitations and Monitoring Page(s). DWQ or "the Division" The Division of Water Quality, Department of Environment and Natural Resources. Effluent Wastewater discharged following all treatment processes from a water pollution control facility or other point source whether treated or untreated. EMC The North Carolina Environmental Management Commission EPA The United States Environmental Protection Agency Facility Closure Cessation of all activities that require coverage under this NPDES permit. Completion of facility closure will allow this permit to be rescinded. Geometric Mean The Nth root of the product of the individual values where N = the number of individual values. For purposes of calculating the geometric mean, values of "0" (or "< [detection level]") shall be considered = 1. Grab Sample Individual samples of at least 100 mL collected over a period of time not exceeding 15 minutes. Grab samples can be collected manually. Grab samples must be representative of the discharge (or the receiving stream, for instream samples). Version 1110912011 DES Permit Standard Conditions -- Page 3 of 18 ubstance ,e designated under 40 CFR Part 116 pursuant to Section 311 of the CWA. s flow measurement The flow measured during the minimum time required for the flow measuring device or method to produce a result in that instance. To the extent practical, instantaneous flow measurements coincide with the collection of any grab samples required for the same sampling period so that together the samples and flow are representative of the discharge during that sampling period. Monthly Average (concentration limit) The arithmetic mean of all "daily discharges" of a pollutant measured during the calendar month. In the case of fecal coliform or other bacterial parameters or indicators, the geometric mean of such discharges. Permit Issuing Authority The Director of the Division of Water Quality. Quarterly Average (concentration limit) The arithmetic mean of all samples taken over a calendar quarter. Severe property damage Substantial physical damage to property, damage to the treatment facilities which causes them to become inoperable, or substantial and permanent loss of natural resources which can reasonably be expected to occur in the absence of a bypass. Severe property damage excludes economic loss caused by delays in production. Toxic Pollutant: Any pollutant listed as toxic under Section 307(a)(1) of the CWA. Upset An incident beyond the reasonable control of the Permittee causing unintentional and temporary noncompliance with permit effluent limitations and/or monitoring requirements. An upset does not include noncompliance caused by operational error, improperly designed treatment facilities, inadequate treatment facilities, lack of preventive maintenance, or careless or improper operation. Weekly Average (concentration limit) The arithmetic mean of all "daily discharges" of a pollutant measured during the calendar week. In the case of fecal coliform or other bacterial parameters or indicators, the geometric mean of such discharges. Section B. General Conditions 1. Duty to Comply The Permittee must comply with all conditions of this permit. Any permit noncompliance constitutes a violation of the CWA and is grounds for enforcement action; for permit termination, revocation and reissuance, or modification; or denial of a permit renewal application [40 CFR 122.411. a. The Permittee shall comply with effluent standards or prohibitions established under section 307(a) of the CWA for toxic pollutants and with standards for sewage sludge use or disposal established under section 405(d) of the CWA within the time provided in the regulations that establish these standards or prohibitions or standards for sewage sludge use or disposal, even if the permit has not yet been modified to incorporate the requirement. b. The CWA provides that any person who violates section[s] 301, 302, 306, 307, 308, 318 or 405 of the Act, or any permit condition or limitation implementing any such sections in a permit issued under section 402, or any requirement imposed in a pretreatment program approved under sections 402(a)(3) or 402(b)(8) of the Act, is subject to a civil penalty not to exceed $37,500 per day for each violation. [33 USC 1319(d) and 40 CFR 122.41(a)(2)] c. The CWA provides that any person who negligently violates sections 301, 302, 306, 307, 308, 318, or 405 of the Act, or any condition or limitation implementing any of such sections in a permit issued under section 402 of the Act, or any requirement imposed in a pretreatment program approved under section 402(a)(3) or 402(b)(8) of the Act, is subject to criminal penalties of $2,500 to $25,000 per day of violation, or Version 1110912011 NPDES Permit Standai imprisonment of not more than 1 year, or both. In the case of a second or subsequent conviction fc violation, a person shall be subject to criminal penalties of not more than $50,000 per day of violal imprisonment of not more than 2 years, or both. [33 USC 1319(c)(1) and 40 CFR 122.41(a)(2)] d. Any person who knowingly violates such sections, or such conditions or limitations is subject to criminal penalties of $5,000 to $50,000 per day of violation, or imprisonment for not more than 3 years, or both. In the case of a second or subsequent conviction for a knowing violation, a person shall be subject to criminal penalties of not more than $100,000 per day of violation, or imprisonment of not more than 6 years, or both. [33 USC 1319(c)(2) and 40 CFR 122.41(a)(2)] e. Any person who knowingly violates section 301, 302, 303, 306, 307, 308, 318 or 405 of the Act, or any permit condition or limitation implementing any of such sections in a permit issued under section 402 of the Act, and who knows at that time that he thereby places another person in imminent danger of death or serious bodily injury, shall, upon conviction, be subject to a fine of not more than $250,000 or imprisonment of not more than 15 years, or both. In the case of a second or subsequent conviction for a knowing endangerment violation, a person shall be subject to a fine of not more than $500,000 or by imprisonment of not more than 30 years, or both. An organization, as defined in section 309(c)(3)(B)(iii) of the CWA, shall, upon conviction of violating the imminent danger provision, be subject to a fine of not more than $1,000,000 and can be fined up to $2,000,000 for second or subsequent convictions. [40 CFR 122.41(a)(2)] f. Under state law, a civil penalty of not more than $25,000 per violation may be assessed against any person who violates or fails to act in accordance with the terms, conditions, or requirements of a permit. [North Carolina General Statutes § 143-215.6A] g. Any person may be assessed an administrative penalty by the Administrator for violating section 301, 302, 306, 307, 308, 318 or 405 of this Act, or any permit condition or limitation implementing any of such sections in a permit issued under section 402 of this Act. Administrative penalties for Class I violations are not to exceed $16,000 per violation, with the maximum amount of any Class I penalty assessed not to exceed $37,500. Penalties for Class 11 violations are not to exceed $16,000 per day for each day during which the violation continues, with the maximum amount of any Class Il penalty not to exceed $177,500. [33 USC 1319(g)(2) and 40 CFR 122.41(a)(3)] 2. Duty to Mitigate The Permittee shall take all reasonable steps to minimize or prevent any discharge or sludge use or disposal in violation of this permit with a reasonable likelihood of adversely affecting human health or the environment [40 CFR 122.41(d)]. 3. Civil and Criminal Liability Except as provided in permit conditions on 'Bypassing" (Part ILCA), "Upsets" (Part II.C.5) and 'Power Failures" (Part H.C.7), nothing in this permit shall be construed to relieve the Permittee from any responsibilities, liabilities, or penalties for noncompliance pursuant to NCGS 143-215.3, 143-215.6 or Section 309 of the Federal Act, 33 USC 1319. Furthermore, the Permittee is responsible for consequential damages, such as fish kills, even though the responsibility for effective compliance may be temporarily suspended. 4. Oil and Hazardous Substance Liability Nothing in this permit shall be construed to preclude the institution of any legal action or relieve the Permittee from any responsibilities, liabilities, or penalties to which the Permittee is or may be subject to under NCGS 143- 215.75 et seq. or Section 311 of the Federal Act, 33 USG 1321. Furthermore, the Permittee is responsible for consequential damages, such as fish kills, even though the responsibility for effective compliance may be temporarily suspended. 5. Property Rights The issuance of this permit does not convey any property rights in either real or personal property, or any exclusive privileges, nor does it authorize any injury to private property or any invasion of personal rights, nor any infringement of Federal, State or local laws or regulations [40 CFR 122.41(g)]. 6. Onshore or Offshore Construction This permit does not authorize or approve the construction of any onshore or offshore physical structures or facilities or the undertaking of any work in any navigable waters. Version 1110912011 DES Permit Standard Conditions Page 5 of 18 7. Severability The provisions of this permit are severable. If any provision of this permit, or the application of any provision of this permit to any circumstances, is held invalid, the application of such provision to other circumstances, and the remainder of this permit, shall not be affected thereby [NCGS 15013-23]. 8. Duty to Provide Information The Permittee shall furnish to the Permit Issuing Authority, within a reasonable time, any information which the Permit Issuing Authority may request to determine whether cause exists for modifying, revoking and reissuing, or terminating this permit or to determine compliance with this permit. The Permittee shall also furnish to the Permit Issuing Authority upon request, copies of records required by this permit [40 CFR 122.41(h)]. 9. Duty to Reapply If the Permittee wishes to continue an activity regulated by this permit after the expiration date of this permit, the Permittee must apply for and obtain a new permit [40 CFR 122.41(b)]. 10. Expiration of Permit The Permittee is not authorized to discharge after the expiration date. In order to receive automatic authorization to discharge beyond the expiration date, the Permittee shall submit such information, forms, and fees as are required by the agency authorized to issue permits no later than 180 days prior to the expiration date unless permission for a later date has been granted by the Director. (The Director shall not grant permission for applications to be submitted later than the expiration date of the existing permit.) [40 CFR 122.21(d)] Any Permittee that has not requested renewal at least 180 days prior to expiration, or any Permittee that does not have a permit after the expiration and has not requested renewal at least 180 days prior to expiration, will subject the Permittee to enforcement procedures as provided in NCGS 143-215.6 and 33 USC 1251 et. seq. 11. Signatory Requirements All applications, reports, or information submitted to the Permit Issuing Authority shall be signed and certified [40 CFR 122.41(k)]. a. All permit applications shall be signed as follows: (1) For a corporation: by a responsible corporate officer. For the purpose of this Section, a responsible corporate officer means: (a) a president, secretary, treasurer or vice president of the corporation in charge of a principal business function, or any other person who performs similar policy or decision making functions for the corporation, or (b) the manager of one or more manufacturing, production, or operating facilities, provided, the manager is authorized to make management decisions which govern the operation of the regulated facility including having the explicit or implicit duty of making major capital investment recommendations, and initiating and directing other comprehensive measures to assure long term environmental compliance with environmental laws and regulations; the manager can ensure that the necessary systems are established or actions taken to gather complete and accurate information for permit application requirements; and where authority to sign documents has been assigned or delegated to the manager in accordance with corporate procedures . (2) For a partnership or sole proprietorship: by a general partner or the proprietor, respectively; or (3) For a municipality, State, Federal, or other public agency: by either a principal executive officer or ranking elected official [40 CFR 122.22]. b. All reports required by the permit and other information requested by the Permit Issuing Authority shall be signed by a person described in paragraph a. above or by a duly authorized representative of that person. A person is a duly authorized representative only if. (1) The authorization is made in writing by a person described above; (2) The authorization specified either an individual or a position having responsibility for the overall operation of the regulated facility or activity, such as the position of plant manager, operator of a well or well field, superintendent, a position of equivalent responsibility, or an individual or position having overall responsibility for environmental matters for the company. (A duly authorized representative may thus be either a named individual or any individual occupying a named position.); and (3) The written authorization is submitted to the Permit Issuing Authority [40 CFR 122.22] Version 1110912011 NPDES Permit Standard Colq Page 6 c. Changes to authorization: If an authorization under paragraph (b) of this section is no longer accurate because a different individual or position has responsibility for the overall operation of the facility, a new authorization satisfying the requirements of paragraph (b) of this section must be submitted to the Director prior to or together with any reports, information, or applications to be signed by an authorized representative [40 CFR 122.221 d. Certification. Any person signing a document under paragraphs a. or b. of this section shall make the following certification [40 CFR 122.22]. NO OTHER STATEMENTS OF CERTIFICATION WILL BE ACCEPTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualifiedpersonnelproperly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility offnes and imprisonment for knowing violations. " 12. Permit Actions This permit may be modified, revoked and reissued, or terminated for cause. The filing of a request by the Permittee for a permit modification, revocation and reissuance, or termination, or a notification of planned changes or anticipated noncompliance does not stay any permit condition [40 CFR 122.41(f)]. 13. Permit Modification, Revocation and Reissuance, or Termination The issuance of this permit does not prohibit the permit issuing authority from reopening and modifying the permit, revoking and reissuing the permit, or terminating the permit as allowed by the laws, rules, and regulations contained in Title 40, Code of Federal Regulations, Parts 122 and 123; Title 15A of the North Carolina Administrative Code, Subchapter 02H .0100; and North Carolina General Statute 143.215.1 et. al. 14. Annual Administering and Compliance Monitoring Fee Requirements The Permittee must pay the annual administering and compliance monitoring fee within thirty days after being billed by the Division. Failure to pay the fee in a timely manner in accordance with 15A NCAC 02H .0105(b)(2) may cause this Division to initiate action to revoke the permit. Section C. Operation and Maintenance of Pollution Controls 1. Certified Operator Owners of classified water pollution control systems must designate operators, certified by the Water Pollution Control System Operators Certification Commission (WPCSOCC), of the appropriate type and grade for the system, and, for each classification must [T15A NCAC 08G .0201]: a. designate one Operator In Responsible Charge (ORC) who possesses a valid certificate of the type and grade at least equivalent to the type and grade of the system; b. designate one or more Back-up Operator(s) in Responsible Charge (Back-up ORCs) who possesses a valid certificate of the type of the system and no more than one grade less than the grade of the system, with the exception of no backup operator in responsible charge is required for systems whose minimum visitation requirements are twice per year; and c. submit a signed completed "Water Pollution Control System Operator Designation Form" to the Commission (or to the local health department for owners of subsurface systems) countersigned by the designated certified operators, designating the Operator in Responsible Charge (ORC) and the Back-up Operator in Responsible Charge (Back-up ORC): (1) 60 calendar days prior to wastewater or residuals being introduced into a new system; or (2) within 120 calendar days following: ➢ receiving notification of a change in the classification of the system requiring the designation of a new Operator in Responsible Charge (ORC) and Back-up Operator in Responsible Charge (Back-up ORC) of the proper type and grade; or ➢ a vacancy in the position of Operator in Responsible Charge (ORC) or Back-up Operator in Responsible Charge (Back-up ORC). Version 1110912011 DES Permit Standard Conditions Page 7 of 18 within seven calendar days of vacancies in both ORC and Back-up ORC positions replacing or designating at least one of the responsibilities. of each Class I facility (or the Back-up ORC, when acting as surrogate for the ORC) must: ➢ Visit the facility as often as is necessary to insure proper operation of the treatment system; the treatment facility must be visited at least weekly ➢ Comply with all other conditions of 15A NCAC 08G .0204. The ORC of each Class II, III and IV facility (or the Back-up ORC, when acting as surrogate for the ORC) must: ➢ Visit the facility as often as is necessary to insure proper operation of the treatment system; the treatment facility must be visited at least five days per week, excluding holidays ➢ Properly manage and document daily operation and maintenance of the facility ➢ Comply with all other conditions of 15A NCAC 08G .0204. 2. Proper Operation and Maintenance The Permittee shall at all times properly operate and maintain all facilities and systems of treatment and control (and related appurtenances) which are installed or used by the Permittee to achieve compliance with the conditions of this permit. Proper operation and maintenance also includes adequate laboratory controls and appropriate quality assurance procedures. This provision requires the Permittee to install and operate backup or auxiliary facilities only when necessary to achieve compliance with the conditions of the permit [40 CFR 122.41(e)]. NOTE: Properly and officially designated operators are fully responsible for all proper operation and maintenance of the facility, and all documentation required thereof, whether acting as a contract operator [subcontractor] or a member of the Permittee's staff. 3. Need to Halt or Reduce not a Defense It shall not be a defense for a Permittee in an enforcement action that it would have been necessary to halt or reduce the permitted activity in order to maintain compliance with the condition of this permit [40 CFR 122.41(c)]. 4. Bypassing of Treatment Facilities a. Bypass not exceeding limitations [40 CFR 122.41(m)(2)] The Permittee may allow any bypass to occur which does not cause effluent limitations to be exceeded, but only if it also is for essential maintenance to assure efficient operation. These bypasses are not subject to the provisions of Paragraphs b. and c. of this section. b. Notice [40 CFR 122.41(m)(3)] (1) Anticipated bypass. If the Permittee knows in advance of the need for a bypass, it shall submit prior notice, if possible at least ten days before the date of the bypass; including an evaluation of the anticipated quality and effect of the bypass. (2) Unanticipated bypass. The Permittee shall submit notice of an unanticipated bypass as required in Part II.E.6. (24-hour notice). c. Prohibition of Bypass (1) Bypass from the treatment facility is prohibited and the Permit Issuing Authority may take enforcement action against a Permittee for bypass, unless: (A) Bypass was unavoidable to prevent loss of life, personal injury or severe property damage; (B) There were no feasible alternatives to the bypass, such as the use of auxiliary treatment facilities, retention of untreated wastes or maintenance during normal periods of equipment downtime. This condition is not satisfied if adequate backup equipment should have been installed in the exercise of reasonable engineering judgment to prevent a bypass which occurred during normal periods of equipment downtime or preventive maintenance; and (C) The Permittee submitted notices as required under Paragraph b. of this section. (2) Bypass from the collection system is prohibited and the Permit Issuing Authority may take enforcement action against a Permittee for a bypass as provided in any current or future system -wide collection system permit associated with the treatment facility. Version 1110912011 NPDES Permit Standard Co1q Page 8 (3) The Permit Issuing Authority may approve an anticipated bypass, after considering its adverse effects, if the Permit Issuing Authority determines that it will meet the three conditions listed above in Paragraph c. (1) of this section. 5. Upsets a. Effect of an upset [40 CFR 122.41(n)(2)]: An upset constitutes an affirmative defense to an action brought for noncompliance with such technology based permit effluent limitations if the requirements of paragraph b. of this condition are met. No determination made during administrative review of claims that noncompliance was caused by upset, and before an action for noncompliance, is final administrative action subject to judicial review. b. Conditions necessary for a demonstration of upset: Any Permittee who wishes to establish the affirmative defense of upset shall demonstrate, through properly signed, contemporaneous operating logs, or other relevant evidence that: (1) An upset occurred and that the Permittee can identify the cause(s) of the upset; (2) The Permittee facility was at the time being properly operated; and (3) The Permittee submitted notice of the upset as required in Part II.E.6.(b) of this permit. (4) The Permittee complied with any remedial measures required under Part II.B.2. of this permit. c. Burden of proof [40 CFR 122.41(n)(4)]: The Permittee seeking to establish the occurrence of an upset has the burden of proof in any enforcement proceeding. Removed Substances Solids, sludges, filter backwash, or other pollutants removed in the course of treatment or control of wastewaters shall be utilized/disposed of in accordance with NCGS 143-215.1 and in a manner such as to prevent any pollutant from such materials from entering waters of the State or navigable waters of the United States except as permitted by the Commission. The Permittee shall comply with all applicable state and Federal regulations governing the disposal of sewage sludge, including 40 CFR 503, Standards for the Use and Disposal of Sewage Sludge; 40 CFR Part 258, Criteria For Municipal Solid Waste Landfills; and 15A NCAC Subchapter 2T, Waste Not Discharged To Surface Waters. The Permittee shall notify the Permit Issuing Authority of any significant change in its sludge use or disposal practices. 7. Power Failures The Permittee is responsible for maintaining adequate safeguards (as required by I5A NCAC 02H .0124) to prevent the discharge of untreated or inadequately treated wastes during electrical power failures either by means of alternate power sources, standby generators or retention of inadequately treated effluent. Section D. Monitoring and Records 1. Representative Sampling Samples collected and measurements taken, as required herein, shall be representative of the permitted discharge. Samples collected at a frequency less than daily shall be taken on a day and time that is representative of the discharge for the period the sample represents. All samples shall be taken at the monitoring points specified in this permit and, unless otherwise specified, before the effluent joins or is diluted by any other wastestream, body of water, or substance. Monitoring points shall not be changed without notification to and the approval of the Permit Issuing Authority [40 CFR 122.410)]. 2. Reporting Monitoring results obtained during the previous month(s) shall be summarized for each month and reported on a monthly Discharge Monitoring Report (DMR) Form (MR 1, 1. 1, 2, 3) or alternative forms approved by the Director, postmarked no later than the last calendar day of the month following the completed reporting period. The first DMR is due on the last day of the month following the issuance of the permit or in the case of a new facility, on the last day of the month following the commencement of discharge. Duplicate signed copies of these, and all other reports required herein, shall be submitted to the following address: Version 1110912011 )ES Permit Standard Conditions Page 9 of 18 NC DENR / Division of Water Quality / Surface Water Protection Section ATTENTION: Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 3. Flow Measurements Appropriate flow measurement devices and methods consistent with accepted scientific practices shall be selected and used to ensure the accuracy and reliability of measurements of the volume of monitored discharges. The devices shall be installed, calibrated and maintained to ensure that the accuracy of the measurements is consistent with the accepted capability of that type of device. Devices selected shall be capable of measuring flows with a maximum deviation of less than 10% from the true discharge rates throughout the range of expected discharge volumes. Flow measurement devices shall be accurately calibrated at a minimum of once per year and maintained to ensure that the accuracy of the measurements is consistent with the accepted capability of that type of device. The Director shall approve the flow measurement device and monitoring location prior to installation. Once -through condenser cooling water flow monitored by pump logs, or pump hour meters as specified in Part I of this permit and based on the manufacturer's pump curves shall not be subject to this requirement. 4. Test Procedures Laboratories used for sample analysis must be certified by the Division. Permittees should contact the Division's Laboratory Certification Section (919 733-3908 or http://portal.ncdenr.org/web/wq/lab/cert) for information regarding laboratory certifications. Facilities whose personnel are conducting testing of field -certified parameters only must hold the appropriate field parameter laboratory certifications. Test procedures for the analysis of pollutants shall conform to the EMC regulations (published pursuant to NCGS 143-215.63 et. seq.), the Water and Air Quality Reporting Acts, and to regulations published pursuant to Section 304(g), 33 USC 1314, of the CWA (as amended), and 40 CFR 136; or in the case of sludge use or disposal, approved under 40 CFR 136, unless otherwise specified in 40 CFR 503, unless other test procedures have been specified in this permit [40 CFR 122.41]. To meet the intent of the monitoring required by this permit, all test procedures must produce minimum detection and reporting levels that are below the permit discharge requirements and all data generated must be reported down to the minimum detection or lower reporting level of the procedure. If no approved methods are determined capable of achieving minimum detection and reporting levels below permit discharge requirements, then the most sensitive (method with the lowest possible detection and reporting level) approved method must be used. Penalties for Tampering The CWA provides that any person who falsifies, tampers with, or knowingly renders inaccurate, any monitoring device or method required to be maintained under this permit shall, upon conviction, be punished by a fine of not more than $10,000 per violation, or by imprisonment for not more than two years per violation, or by both. If a conviction of a person is for a violation committed after a first conviction of such person under this paragraph, punishment is a fine of not more than $20,000 per day of violation, or by imprisonment of not more than 4 years, or both [40 CFR 122.41]. 6. Records Retention Except for records of monitoring information required by this permit related to the Permittee's sewage sludge use and disposal activities, which shall be retained for a period of at least five years (or longer as required by 40 CFR 503), the Permittee shall retain records of all monitoring information, including: ➢ all calibration and maintenance records ➢ all original strip chart recordings for continuous monitoring instrumentation ➢ copies of all reports required by this permit ➢ copies of all data used to complete the application for this permit These records or copies shall be maintained for a period of at least 3 years from the date of the sample, measurement, report or application. This period may be extended by request of the Director at any time [40 CFR 122.41]. Version 1110912011 7 NPDES Permit Standar I Recording Results For each measurement or sample taken pursuant to the requirements of this permit, the Permittee shall following information [40 CFR 122.411: a. The date, exact place, and time of sampling or measurements; b. The individual(s) who performed the sampling or measurements; c. The date(s) analyses were performed; d. The individual(s) who performed the analyses; e. The analytical techniques or methods used; and f. The results of such analyses. 8. Inspection and Entry The Permittee shall allow the Director, or an authorized representative (including an authorized contractor acting as a representative of the Director), upon the presentation of credentials and other documents as may be required by law, to; a. Enter, at reasonable times, upon the Permittee's premises where a regulated facility or activity is located or conducted, or where records must be kept under the conditions of this permit; b. Have access to and copy, at reasonable times, any records that must be kept under the conditions of this permit; c. Inspect at reasonable times any facilities, equipment (including monitoring and control equipment), practices, or operations regulated or required under this permit; and d. Sample or monitor at reasonable times, for the purposes of assuring permit compliance or as otherwise authorized by the CWA, any substances or parameters at any location [40 CFR 122.41(i)]. Section E Reporting Requirements 1. Change in Discharge All discharges authorized herein shall be consistent with the terms and conditions of this permit. The discharge of any pollutant identified in this permit more frequently than or at a level in excess of that authorized shall constitute a violation of the permit. 2. Planned Changes The Permittee shall give notice to the Director as soon as possible of any planned physical alterations or additions to the permitted facility [40 CFR 122.41(1)]. Notice is required only when: a. The alteration or addition to a permitted facility may meet one of the criteria for new sources at 40 CFR 122.29(b); or b. The alteration or addition could significantly change the nature or increase the quantity of pollutants discharged. This notification applies to pollutants subject neither to effluent limitations in the permit, nor to notification requirements under 40 CFR 122.42(a)(1); or c. The alteration or addition results in a significant change in the Permittee's sludge use or disposal practices, and such alteration, addition or change may justify the application of permit conditions that are different from or absent in the existing permit, including notification of additional use or disposal sites not reported during the permit application process or not reported pursuant to an approved land application plan. 3. Anticipated Noncompliance The Permittee shall give advance notice to the Director of any planned changes to the permitted facility or other activities that might result in noncompliance with the permit [40 CFR 122.41(1)(2)]. 4. Transfers This permit is not transferable to any person without prior written notice to and approval from the Director in accordance with 40 CFR 122.61. The Director may condition approval in accordance with NCGS 143-215.1, in particular NCGS 143-215. 1 (b)(4)b.2., and may require modification or revocation and reissuance of the permit, or a minor modification; to identify the new permittee and incorporate such other requirements as may be necessary under the CWA [40 CFR 122.41(1)(3), 122.61] or state statute. Version 1110912011 JES Permit Standard Conditions Page 11 of 18 5. Monitoring Reports Monitoring results shall be reported at the intervals specified elsewhere in this permit [40 CFR 122.41(1)(4)]. a. Monitoring results must be reported on a Discharge Monitoring Report (DMR) (See Part II.D.2) or forms provided by the Director for reporting results of monitoring of sludge use or disposal practices. b. If the Permittee monitors any pollutant more frequently than required by this permit using test procedures approved under 40 CFR Part 136 and at a sampling location specified in this permit or other appropriate instrument governing the discharge, the results of such monitoring shall be included in the calculation and reporting of the data submitted on the DMR. 6. Twenty-four Hour Reporting a. The Permittee shall report to the Director or the appropriate Regional Office any noncompliance that potentially threatens public health or the environment. Any information shall be provided orally within 24 hours from the time the Permittee became aware of the circumstances. A written submission shall also be provided within 5 days of the time the Permittee becomes aware of the circumstances. The written submission shall contain a description of the noncompliance, and its cause; the period of noncompliance, including exact dates and times, and if the noncompliance has not been corrected, the anticipated time it is expected to continue; and steps taken or planned to reduce, eliminate, and prevent reoccurrence of the noncompliance [40 CFR 122.41(1)(6)]. b. The Director may waive the written report on a case -by -case basis for reports under this section if the oral report has been received within 24 hours. c. Occurrences outside normal business hours may also be reported to the Division's Emergency Response personnel at (800) 662-7956, (800) 858-0368 or (919) 733-3300. 7. Other Noncompliance The Permittee shall report all instances of noncompliance not reported under Part II.E.5 and 6. of this permit at the time monitoring reports are submitted. The reports shall contain the information listed in Part II.E.6. of this permit [40 CFR 122.41(1)(7)]. 8. Other Information Where the Permittee becomes aware that it failed to submit any relevant facts in a permit application, or submitted incorrect information in a permit application or in any report to the Director, it shall promptly submit such facts or information [40 CFR 122.41(1)(8)]. 9. Noncompliance Notification The Permittee shall report by telephone to either the central office or the appropriate regional office of the Division as soon as possible, but in no case more than 24 hours or on the next working day following the occurrence or first knowledge of the occurrence of any of the following: a. Any occurrence at the water pollution control facility which results in the discharge of significant amounts of wastes which are abnormal in quantity or characteristic, such as the dumping of the contents of a sludge digester; the known passage of a slug of hazardous substance through the facility; or any other unusual circumstances. b. Any process unit failure, due to known or unknown reasons, that render the facility incapable of adequate wastewater treatment such as mechanical or electrical failures of pumps, aerators, compressors, etc. c. Any failure of a pumping station, sewer line, or treatment facility resulting in a by-pass without treatment of all or any portion of the influent to such station or facility. Persons reporting such occurrences by telephone shall also file a written report within 5 days following first knowledge of the occurrence. Also see reporting requirements for municipalities in Part IV.C.2.c. of this permit. 10. Availabilijy of Reports Except for data determined to be confidential under NCGS 143-215.3 (a)(2) or Section 308 of the Federal Act, 33 USC 1318, all reports prepared in accordance with the terms shall be available for public inspection at the offices of the Division. As required by the Act, effluent data shall not be considered confidential. Knowingly making any false statement on any such report may result in the imposition of criminal penalties as provided for in NCGS 143- 215.1(b)(2) or in Section 309 of the Federal Act. Version 1110912011 11 NPDES Permit Standar I Penalties for Falsification of Reports The CWA provides that any person who knowingly makes any false statement, representation, or certii any record or other document submitted or required to be maintained under this permit, including mon reports or reports of compliance or noncompliance shall, upon conviction, be punished by a fine of not more than $25,000 per violation, or by imprisonment for not more than two years per violation, or by both [40 CFR 122.41]. 12. Annual Performance Reports Permittees who own or operate facilities that collect or treat municipal or domestic waste shall provide an annual report to the Permit Issuing Authority and to the users/customers served by the Permittee (NCGS 143-215.1C). The report shall summarize the performance of the collection or treatment system, as well as the extent to which the facility was compliant with applicable Federal or State laws, regulations and rules pertaining to water quality. The report shall be provided no later than sixty days after the end of the calendar or fiscal year, depending upon which annual period is used for evaluation. The report shall be sent to: NC DENR / Division of Water Quality [Surface Water Protection Section ATTENTION: Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 Version 1110912011 )ES Permit Standard Conditions Page 13 of 18 PART III OTHER REQUIREMENTS Section A. Construction a. The Permittee shall not commence construction of wastewater treatment facilities, nor add to the plant's treatment capacity, nor change the treatment process(es) utilized at the treatment plant unless (1) the Division has issued an Authorization to Construct (AtC) permit or (2) the Permittee is exempted from such AtC permit requirements under Item b. of this Section. b. In accordance with NCGS 143-215.1(a5) [SL 2011-394], no permit shall be required to enter into a contract for the construction, installation, or alteration of any treatment work or disposal system or to construct, install, or alter any treatment works or disposal system within the State when the system's or work's principle function is to conduct, treat, equalize, neutralize, stabilize, recycle, or dispose of industrial waste or sewage from an industrial facility and the discharge of the industrial waste or sewage is authorized under a permit issued for the discharge of the industrial waste or sewage into the waters of the State. Notwithstanding the above, the permit issued for the discharge may be modified if required by federal regulation. C. Issuance of an AtC will not occur until Final Plans and Specifications for the proposed construction have been submitted by.the Permittee and approved by the Division. Section B. Groundwater Monitoring The Permittee shall, upon written notice from the Director, conduct groundwater monitoring as may be required to determine the compliance of this NPDES permitted facility with the current groundwater standards. Section C. Changes in Discharges of Toxic Substances The Permittee shall notify the Permit Issuing Authority as soon as it knows or has reason to believe (40 CFR 122.42): a. That any activity has occurred or will occur which would result in the discharge, on a routine or frequent basis, of any toxic pollutant which is not limited in the permit, if that discharge will exceed the highest of the following "notification levels"; (1) One hundred micrograms per liter (100 µg/L); (2) Two hundred micrograms per liter (200 µg/L) for acrolein and acrylonitrile; five hundred micrograms per liter (500 µg/L) for 2,4-dinitrophenol and for 2-methyl-4,6-dinitrophenol; and one milligram per liter (1 mg/L) for antimony; (3) Five times the maximum concentration value reported for that pollutant in the permit application. b. That any activity has occurred or will occur which would result in any discharge, on a non -routine or infrequent basis, of a toxic pollutant which is not limited in the permit, if that discharge will exceed the highest of the following "notification levels"; (1) Five hundred micrograms per liter (500 µg/L); (2) One milligram per liter (1 mg/L) for antimony; (3) Ten times the maximum concentration value reported for that pollutant in the permit application. Section D. Facility Closure Requirements The Permittee must notify the Division at least 90 days prior to the closure of any wastewater treatment system covered by this permit. The Division may require specific measures during deactivation of the system to prevent adverse impacts to waters of the State. This permit cannot be rescinded while any activities requiring this permit continue at the permitted facility. Version 1110912011 NPDES Permit Standar P PART IV SPECIAL CONDITIONS FOR MUNICIPAL FACILITIES Section A. Definitions In addition to the definitions in Part II of this permit, the following definitions apply to municipal facilities: Indirect Discharge or Industrial User Any non -domestic source that discharges wastewater containing pollutants into a POTW regulated under section 307(b), (c) or (d) of the CWA. [40 CFR 403.3 (i) and 0) and 15A NCAC 02H .0903(b)(11)] Interference Inhibition or disruption of the POTW treatment processes; operations; or its sludge process, use, or disposal which causes or contributes to a violation of any requirement of the Permittee's (or any satellite POTW's if different from the Permittee) NPDES, collection system, or non -discharge permit or prevents sewage sludge use or disposal in compliance with specified applicable State and Federal statutes, regulations, or permits. [15A NCAC 02H .0903(b)(14)] Pass Through A discharge which exits the POTW into waters of the State in quantities or concentrations which, alone or with discharges from other sources, causes a violation, including an increase in the magnitude or duration of a violation, of the Permittee's (or any satellite POTW's, if different from the Permittee) NPDES, collection system, or non -discharge permit. [15A NCAC 02H .0903(b)(23)] Publicly Owned Treatment Works (POTW) A treatment works as defined by Section 212 of the CWA, which is owned by a State or local government organization. This definition includes any devices and systems used in the storage, treatment, recycling and reclamation of municipal sewage or industrial wastes of a liquid nature. It also includes the collection system, as defined in 15A NCAC 2T .0402, only if it conveys wastewater to a POTW treatment plant. The term also means the local government organization, or municipality, as defined in section 502(4) of the CWA, which has jurisdiction over indirect discharges to and the discharges from such a treatment works. In this context, the organization may be the owner of the POTW treatment plant or the owner of the collection system into which an indirect discharger discharges. This second type of POTW may be referred to as a "satellite POTW organization." [15A NCAC 02H .0903(b)(26)] "Significant Industrial User" or "SIU" An Industrial User that discharges wastewater into a publicly owned treatment works and that [15A NCAC 02H .0903(b)(33)]: 1. Discharges an average of 25,000 gallons per day or more of process wastewater to the POTW (excluding sanitary, noncontact cooling and boiler blowdown wastewaters); or 2. Contributes process wastewater which makes up five percent or more of the NPDES or non -discharge permitted flow limit or organic capacity of the POTW treatment plant. In this context, organic capacity refers to BOD, TSS and ammonia; or 3. Is subject to categorical standards under 40 CFR Part 403.6 and 40 CFR Parts 405-471; or 4. Is designated as such by the Permittee on the basis that the Industrial User has a reasonable potential for adversely affecting the POTW's operation or for violating any pretreatment standard or requirement, or the POTW's effluent limitations and conditions in its NPDES or non -discharge permit, or to limit the POTW's sludge disposal options; 5. Subject to approval under 15A NCAC 02H .0907(b), the Permittee may determine that an Industrial User meeting the criteria in paragraphs 1 or 2 of this definition above has no reasonable potential for adversely affecting the POTW's operation or for violating any pretreatment standard or requirement, the POTW's effluent limitations and conditions in its NPDES or non -discharge permit, or to limit the POTW's sludge disposal options, and thus is not a Significant Industrial User (SIU); or 6. Subject to approval under 15A NCAC 02H .0907(b), the Permittee may determine that an Industrial User meeting the criteria in paragraph 3 of this definition above meets the requirements of 40 CFR Part 403.3(v)(2) and thus is a non -significant categorical Industrial User. Section B. Publicly Owned Treatment Works (POTWs) Version 1110912011 DES Permit Standard Conditions Page 15 of 18 All POTWs must provide adequate notice to the Director of the following [40 CFR 122.42(b)]: 1. Any new introduction of pollutants into the POTW from an indirect discharger, regardless of the means of transport, which would be subject to section 301 or 306 of CWA if it were directly discharging those pollutants; and 2. Any substantial change in the volume or character of pollutants being introduced by an indirect discharger as influent to that POTW at the time of issuance of the permit. 3. For purposes of this paragraph, adequate notice shall include information on (1) the quality and quantity of effluent introduced into the POTW, and (2) any anticipated impact that may result from the change of the quantity or quality of effluent to be discharged from the POTW. Section C. Municipal Control of Pollutants from Industrial Users. 1. Effluent limitations are listed in Part I of this permit. Other pollutants attributable to inputs from Industrial Users discharging to the POTW may be present in the Permittee's discharge. At such time as sufficient information becomes available to establish limitations for such pollutants, this permit may be revised to specify effluent limitations for any or all of such other pollutants in accordance with best practicable technology or water quality standards. 2. Prohibited Discharges a. The Permittee shall develop and enforce their Pretreatment Program to implement the prohibition against the introduction of pollutants or discharges into the waste treatment system or waste collection system which cause or contribute to Pass Through or Interference as defined in 15A NCAC 02H .0900 and 40 CFR 403. [40 CFR 403.5(a)(1)] b. The Permittee shall develop and enforce their Pretreatment Program to implement the prohibitions against the introduction of the following wastes in the waste treatment or waste collection system [40 CFR 403.5(b)]: (1) Pollutants which create a fire or explosion hazard in the POTW, including, but not limited to, wastestreams with a closed cup flashpoint of less than 140 degrees Fahrenheit or 60 degrees Centigrade using the test methods specified in 40 CFR 261.21; (2) Pollutants which cause corrosive structural damage to the POTW, but in no case discharges with pH lower than 5.0, unless the works is specifically designed to accommodate such discharges; (3) Solid or viscous pollutants in amounts which cause obstruction to the flow in the POTW resulting in Interference; (4) Any pollutant, including oxygen demanding pollutants (BOD, etc.) released in a Discharge at a flow rate and/or pollutant concentration which will cause Interference with the POTW; (5) Heat in amounts which will inhibit biological activity in the POTW resulting in Interference, but in no case heat in such quantities that the temperature at the POTW Treatment Plant exceeds 40°C (104°F) unless the Division, upon request of the POTW, approves alternate temperature limits; (6) Petroleum oil, non -biodegradable cutting oil, or products of mineral oil origin in amounts that will cause Interference or Pass Through; (7) Pollutants which result in the presence of toxic gases, vapors, or fumes within the POTW in a quantity that may cause acute worker health and safety problems; or (8) Any trucked or hauled pollutants, except at discharge points designated by the POTW. c. The Permittee shall investigate the source of all discharges into the POTW, including slug loads and other unusual discharges, which have the potential to adversely impact the Permittee's Pretreatment Program and/or the operation of the POTW. The Permittee shall report such discharges into the POTW to the Director or the appropriate Regional Office. Any information shall be provided orally within 24 hours from the time the Permittee became aware of the circumstances. A written submission shall also be provided within 5 days of the time the Permittee becomes aware of the circumstances. The written submission shall contain a description of the discharge; the investigation into possible sources; the period of the discharge, including exact dates and times; if the discharge has not ceased, the anticipated time it is expected to continue; and steps taken or planned to reduce, eliminate, and prevent reoccurrence of the noncompliance, _j Version 1110912011 I NPDES Permit Standard Co?X Page 16 3. With regard to the effluent requirements listed in Part I of this permit, it may be necessary for the Permittee to supplement the requirements of the Federal Pretreatment Standards (40 CFR, Part 403) to ensure compliance by the Permittee with all applicable effluent limitations. Such actions by the Permittee may be necessary regarding some or all of the industries discharging to the municipal system. 4. The Permittee shall require any Industrial User (IU) discharging to the POTW to meet Federal Pretreatment Standards developed under Section 307(b) of the Act as amended (which includes categorical standards and specific local limits, best management practices and narrative requirements). Prior to accepting wastewater from any Significant Industrial User (SIU), the Permittee shall either develop and submit to the Division a new Pretreatment Program or, as necessary, a modification of an existing Pretreatment Program, for approval as required under section D below as well as 15A NCAC 02H .0907(a) and (b). [40 CFR 122.440)(2)] 5. This permit shall be modified, or alternatively, revoked and reissued, to incorporate or modify an approved POTW Pretreatment Program or to include a compliance schedule for the development of a POTW Pretreatment Program as required under Section 402 (b)(8) of the CWA and implementing regulations or by the requirements of the approved State pretreatment program, as appropriate. Section D. Pretreatment Programs Under authority of sections 307 (b) and (c) and 402(b)(8) of the CWA and implementing regulations 40 CFR 403, North Carolina General Statute 143-215.3(14) and implementing regulations 15A NCAC 02H .0900, and in accordance with the approved pretreatment program, all provisions and regulations contained and referenced in the pretreatment program submittal are an enforceable part of this permit. [40 CFR 122.440)(2)] The Permittee shall operate its approved pretreatment program in accordance with Section 402(b)(8) of the CWA, 40 CFR 403, 15A NCAC 02H .0900, and the legal authorities, policies, procedures, and financial provisions contained in its pretreatment program submission and Division approved modifications thereof. Such operation shall include but is not limited to the implementation of the following conditions and requirements. Terms not defined in Part II or Part IV of this permit are as defined in 15A NCAC 02H .0903 and 40 CFR 403.3. 1. Sewer Use Ordinance (SUO) The Permittee shall maintain adequate legal authority to implement its approved pretreatment program. [15A NCAC 02H .0903(b)(32), .0905 and .0906(b)(1); 40 CFR 403.8(f)(1) and 403.9(b)(1) and (2)] 2. Industrial Waste Survey (IWS) The Permittee shall implement an IWS consisting of the survey of users of the POTW collection system or treatment plant, as required by 40 CFR 403.8(f)(2)(i-iii) and 15A NCAC 02H .0905 [also 40 CFR 122.440)(1)], including identification of all Industrial Users that may have an impact on the POTW and the character and amount of pollutants contributed to the POTW by these Industrial Users and identification of those Industrial Users meeting the definition of SIU. Where the Permittee accepts wastewater from one or more satellite POTWs, the IWS for the Permittee shall address all satellite POTW services areas, unless the pretreatment program in those satellite service areas is administered by a separate Permittee with an approved Pretreatment Program. The Permittee shall submit a summary of its IWS activities to the Division at least once every five years, and as required by the Division. The IWS submission shall include a summary of any investigations conducted under paragraph C.2.c. of this Part. [15A NCAC 02H .0903(b)(13), .0905 and .0906(b)(2); 40 CFR 403.8(f)(2) and 403.9] 3. Monitoring Plan The Permittee shall implement a Division -approved Monitoring Plan for the collection of facility specific data to be used in a wastewater treatment plant Headworks Analysis (HWA) for the development of specific pretreatment local limits. Effluent data from the Plan shall be reported on the DMRs (as required by Parts II.D and II.E.5.). [15A NCAC 02H .0903(b)(16), .0906(b)(3) and .0905] 4. Headworks Analysis (HWA) and Local Limits The Permittee shall obtain Division approval of a HWA at least once every five years, and as required by the Division. Within 180 days of the effective date of this permit (or any subsequent permit modification) the Permittee shall submit to the Division a written technical evaluation of the need to revise local limits (i.e., an updated HWA or documentation of why one is not needed) [40 CFR 122.44]. The Permittee shall develop, in accordance with 40 CFR 403.5(c) and 15A NCAC 02H .0909, specific Local Limits to implement the prohibitions listed in 40 CFR 403.5(a) and (b) and 15A NCAC 02H .0909. Pursuant to 40 CFR 403.5, local limits are Version 1110912011 )ES Permit Standard Conditions Page 17 of 18 Etble Pretreatment Standards as defined by 40 CFR 403.3(1). [15A NCAC 02H .0903(b)(10), .0905, and )(4)]' uiuuD�11al User Pretreatment Permits (IUP) &Allocation Tables In accordance with NCGS 143-215.1, the Permittee shall issue to all Significant Industrial Users, permits for operation of pretreatment equipment and discharge to the Permittee's collection system or treatment works. These permits shall contain limitations, sampling protocols, reporting requirements, appropriate standard and special conditions, and compliance schedules as necessary for the installation of treatment and control technologies to assure that their wastewater discharge will meet all applicable pretreatment standards and requirements. The Permittee shall maintain a current Allocation Table (AT) which summarizes the results of the HWA and the limits from all IUPs. Permitted IUP loadings for each parameter cannot exceed the treatment capacity of the POTW as determined by the HWA. [15A NCAC 02H .0906(b)(6), .0909, .0916, and .0917; 40 CFR 403.5, 403.8(f)(1)(iii); NCGS 143-215.67(a)] Authorization to Construct (AtQ The Permittee shall ensure that an Authorization to Construct permit (AtC) is issued to all applicable Industrial Users for the construction or modification of any pretreatment facility. Prior to the issuance of an AtC, the proposed pretreatment facility and treatment process must be evaluated for its capacity to ,comply with all Industrial User Pretreatment Permit (IUP) limitations. [15A NCAC 02H .0906(b)(7) and .0905; NCGS 143- 215. 1 (a)(8)] 7. POTW Inspection & Monitoring of their IUs The Permittee shall conduct inspection, surveillance, and monitoring activities as described in its Division approved pretreatment program in order to determine, independent of information supplied by Industrial Users, compliance with applicable pretreatment standards. [15A NCAC 02H .0908(e); 40 CFR 403.8(f)(2)(v)] The Permittee must: a. Inspect all Significant Industrial Users (SIUs) at least once per calendar year; b. Sample all Significant Industrial Users (SIUs) at least once per calendar year for all SIU permit -limited parameters including flow except as allowed under 15A NCAC .0908(e); and c. At least once per year, document an evaluation of any non -significant categorical Industrial User for compliance with the requirements in 40 CFR 403.3(v)(2), and either continue or revoke the designation as non- significant. 8. IU Self Monitoringand Reporting The Permittee shall require all Industrial Users to comply with the applicable monitoring and reporting requirements outlined in the Division -approved pretreatment program, the industry's pretreatment permit, or in 15A NCAC 02H .0908. [15A NCAC 02H .0906(b)(5) and .0905; 40 CFR 403.8(f)(1)(v) and (2)(iii); 40 CFR 122.440)(2) and 40 CFR 403.12] 9. Enforcement Response Plan (ERP) The Permittee shall enforce and obtain appropriate remedies for violations of all pretreatment standards promulgated pursuant to section 307(b) and (c) of the CWA (40 CFR 405 et. seq.), prohibitive discharge standards as set forth in 40 CFR 403.5 and 15A NCAC 02H .0909, specific local limitations; and other pretreatment requirements. All remedies, enforcement actions and other, shall be consistent with the Enforcement Response Plan (ERP) approved by the Division. [15A NCAC 02H .0903(b)(7), .0906(b)(8) and .0905; 40 CFR 403.8(f)(5)] 10. Pretreatment Annual Reports (PAR) The Permittee shall report to the Division in accordance with 15A NCAC 02H .0908. In lieu of submitting annual reports, Modified Pretreatment Programs developed under 15A NCAC 02H .0904 (b) may be required to submit a partial annual report or to meet with Division personnel periodically to discuss enforcement of pretreatment requirements and other pretreatment implementation issues. For all other active pretreatment programs, the Permittee shall submit two copies of a Pretreatment Annual Report (PAR) describing its pretreatment activities over the previous calendar year to the Division at the following address: Version 1110912011 NPDES Permit Standarc R NC DENR / Division of Water Quality / Surface Water Protection Section Pretreatment, Emergency Response, and Collection Systems (PERCS) Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 These reports shall be submitted by March 1 of each year and shall contain the following: a. Narrative A narrative summary detailing actions taken, or proposed, by the Permittee to correct significant non- compliance and to ensure compliance with pretreatment requirements; b. Pretreatment Program Summary (PPS) A pretreatment program summary (PPS) on forms or in a format provided by the Division; c. Significant Non -Compliance Report (SNCR) A list of Industrial Users (IUs) in significant noncompliance (SNC) with pretreatment requirements, and the nature of the violations on forms or in a format provided by the Division; d. Industrial Data Summary Forms (IDSF) Monitoring data from samples collected by both the POTW and the Significant Industrial Users (SIUs). These analytical results must be reported on Industrial Data Summary Forms (IDSF) or on other forms or in a format provided by the Division; e. Other Information Copies of the POTW's allocation table, new or modified enforcement compliance schedules, public notice of IUs in SNC, a summary of data or other information related to significant noncompliance determinations for IUs that are not considered SIUs, and any other information, upon request, which in the opinion of the Director is needed to determine compliance with the pretreatment implementation requirements of this permit; 11. Public Notice The Permittee shall publish annually a list of Industrial Users (IUs) that were in significant noncompliance (SNC) as defined in the Permittee's Division -approved Sewer Use Ordinance with applicable pretreatment requirements and standards during the previous twelve month period. This list shall be published within four months of the applicable twelve-month period. [15A NCAC 02H .0903(b)(34), .0908(b)(5) and .0905 and 40 CFR 403.8(f)(2)(viii)] 12. Record Keeping The Permittee shall retain for a minimum of three years records of monitoring activities and results, along with support information including general records, water quality records, and records of industrial impact on the POTW and shall retain all other Pretreatment Program records as required by 15A NCAC 02H .0908(f). [15A NCAC 02H .0908(f); 40 CFR 403.12(o)] 13. Pretreatment Program Resources The Permittee shall maintain adequate funding and qualified personnel to accomplish the objectives of its approved pretreatment program. and retain a written description of those current levels of inspection. [15A NCAC 02H .0906(b)(9) and (10) and .0905; 40 CFR 403.8(f)(3), 403.9(b)(3)] 14. Modification to Pretreatment Programs Modifications to the approved pretreatment program including but not limited to local limits modifications, POTW monitoring of their Significant Industrial Users (SIUs), and Monitoring Plan modifications, shall be considered a permit modification and shall be governed by 40 CFR 403.18, 15 NCAC 02H .0114 and 15A NCAC 02H .0907. Version 11/09/2011 A=rl 101ina Department of Environme #� -av t . e� Division of Water UillIfT Ln is Charles Wakild, P.E:- Dee Freeman Director APR 1 7 2012 ' I ;Secretary F -L WATER QUALITY SECTION 1 A ril16 2010' p ' AShtEVIL_LE RE :ION,4� L OFFICE AUBREY DEAVER PRESIDENT A&D WATER SERVICE, INC PO BOX 1407 PISGAH FOREST NC 28768 Subject: Receipt of permit renewal application NPDES Permit NCO059430 Sapphire Lakes Plant #2 Transylvania County Dear Mr. Deaver: The NPDES Unit received your permit renewal application on April 12, 2012. A member of the. NPDES Unit will review your application. They will contact you if additional information is required to complete your permit renewal. You should expect to receive a draft permit approximately 30-45 days before your existing permit expires. If you have any additional questions concerning renewal of the subject permit, please contact Bob Sledge at (919) 807-6398. Sincerely, Dina Sprinkle Point Source Branch cc: CENTRAL FILES shevll' e�ReQaonal Os;ffic"'e. /�'S:ursface WatervProtec � ozx NPDES Unit 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Location: 512 N. Salisbury St. Raleigh, North Carolina 27604 Phone: 919-807-63001 FAX: 919-807-6492 Internet: www:ncwaterquality.org An Equal Opportunity t Affirmative Action Employer Nne orthCarolina ;Vatllralll� f . 4�, NPDES APPLICATION - FORM D Fprop7vately owned treatment systems treating 100% domestic wastewaters <1.0 MGD Mail the complete application to: N. C. DENR / Division of Water Quality / NPDES Unit 1617 Mail Service Center, Raleigh, NC 27699-1617 NFDES Permat w C0069439 If you are completing this form in computer use the TAB key or the up - down arrows to move from one field to the next. To check the boxes, click your mouse on top of the box. Otherwise, please print or type. 1. Contact Information: Owner Name A & D Water Service, Inc. Facility Name Sapphire Lakes Plant #2 Mailing Address P O Box 1407 City Pisgah Forest State / Zip Code N C / 28768 Telephone Number (828) 884-9772 Fax Number (828)884-8632 e-mail Address admaint@citcom.net 2. Location of facility producing discharge: Check here if same address as above ❑ Street Address or State Road Off US Highway 64 at Sapphire Lakes near Round Mtn City Sapphire State / Zip Code N C / 28774 County Transylvania 3. Operator Information: Name of the firm, public organization or other entity that operates the facility. (Note that this is not referring to the Operator in Responsible Charge or ORC) Name A & D Water Service, Inc Mailing Address P O Box 1407 City Pisgah Forest State / Zip Code N C / 28768 0 Telephone Number (828)884-9772 r D r Fax Number (828)884-8632 APR 12 2012 1 of 3 Form-D 05/08 W, NPDES APPLICATION - FORM D privately owned treatment systems treating 100% domestic wastewaters <1.0 MGD . 4. 'Description of wastewater: Facility Generat�Wastewater(check all that applyr Industrial ❑ Number of Employees Commercial ❑ _ Number of Employees _ Residential X Number of Homes 8 School ❑ Number of Students/Staff Other ❑ _ Explain: Describe the source(s) of wastewater (example: subdivision, mobile home park, shopping centers, restaurants, etc.): Subdivison (condominiums) Population served: 12 5. Type of collection system X Separate (sanitary sewer only) ❑ Combined (storm sewer and sanitary sewer) 6. Outfall Information: Number of separate discharge points 1 Outfall Identification number(s) 001 Is the outfall equipped with a diffuser? X Yes ❑ No 7. Name of receiving stream(s) (Provide a map shouting the exact location of each outfall). James Creek S. Frequency of Discharge: ❑ Continuous X Intermittent If intermittent: Days per week discharge occurs: Varies Duration: 10 mins. 9. Describe the treatment system List all installed components, including capacities, provide design removal for BOD, TSS, nitrogen and phosphorus. If the space provided is not sufficient, attach the description of the treatment system in a separate sheet of paper. Surface sand filters with chlorination 2of3 Farm-D 05108 pppp, NPDES APPLICATION - FORM D privately owned treatment systems treating 100% domestic wastewaters <1.0 MGD 10. Flow Information: Treatment Plant Design flow 0.0049 MGD Annual Average daily flow 0.0000 MGD (for the previous 3 years) Maximum daily flow 0.0000 MGD (for the previous 3 years) 11. Is this facility located on Indian country? ❑ Yes X No 12. Effluent Data Provide data for the parameters listed. Fecal Coliform, Temperature and pH shall be grab samples, for all other parameters 24-hour composite sampling shall be used. If more than one analysis is reported, report daily maximum and monthly average. If only one analysis is reported, report as daily maximum. Parameter Daily Maximum Monthly Average Units of Measurement Biochemical Oxygen Demand (BODs) N/A N/A mg/L Fecal Coliform N/A N/A col/ 100 ml Total Suspended Solids N/A N/A mg/L Temperature (Summer) N/A N/A deg C Temperature (Winter) N/A N/A deg C pH N/A N/A S.U. 13. List all permits, construction approvals and/or applications: Type Permit Number Type Hazardous Waste (RCRA) UIC (SDWA) NPDES PSD (CAA) Non -attainment program (CAA) 14. APPLICANT CERTIFICATION NESHAPS (CAA) Ocean Dumping (MPRSA) Dredge or fill (Section 404 or CWA) Other Permit Number I certify that I am familiar with the information contained in the application and that to the best of my knowledge and belief such information is true, complete, and accurate. Printed nanik of Applicant Title Date North Carolina General Statute 143-215.6 (b)(2) states: Any person who knowingly makes any false statement representation, or certification in any application, record, report, plan, or other document files or required to be maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, or who falsifies, tampers with, or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, shall be guilty of a misdemeanor punishable by a fine not to exceed $25,000, or by imprisonment not to exceed six months, or by both. (18 U.S.C. Section 1001 provides a punishment by a fine of not more than $25,000 or imprisonment not more than 5 years, or both, for a similar offense.) 3 of 3 Form-D 05/08 'Ali 1 NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Governor Director SURFACE WATER PROTECTION SECTION September 10, 2010 Mr. Aubrey L. Deaver A&D Water Service, Inc. PO Box 1407 Pisgah Forest, NC 28768-1407 Dee Freeman Secretary SUBJECT: Compliance Evaluation Inspection Sapphire Lakes Plant WWTP #2 Permit No: NCO059439 Transylvania County Dear Mr. Deaver: Enclosed please find a copy of the Compliance Evaluation Inspection form from the inspection conducted on August 24, 2010. The facility was found to be in compliance with permit NC0059439. Please refer to the enclosed inspection report for additional observations and comments. If you or your staff should have any questions, please call me at 828-296-4662. Sincerely, Wanda P. Frazier Environmental .Specialist Enclosure cc: Central Files S:\SWP\ ransy vania a r1 M r� Sap dire Lakes WWTP #2 59439\CE1.8-24-10.doc SURFACE WATER PROTECTION — ASHEVILLE REGIONAL OFFICE Location: 2090 U.S. Highway 70, Swannanoa, NC 28778 NonrthCarolina Phone: (828) 296-4500 \ FAX: 828 299-7043 \ Customer Service: 1-877-623-6748 ;Vatutllallff Internet: www.ncwaterauality.org .1� :/ United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 I NI 2 15I 31 NCO059439 111 121 10/08/24 117 181 CI 191 SI 20I I L. Remarks 211 I I I I I I I I I I I I I I I I I I 1 1 I I I I I I I I I I I I I I I I I I I I I I I I 116 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved----- 67I 1. 0 169 701 31 71 IJ 721 NJ 73I I 174 751 I I I I I Li W Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) Sapphire Lakes Plant WWTP #2 11:10 AM 10/08/24 07/11/01 Exit Time/Date Permit Expiration Date 1600 vs Hwy 64 W Sapphire NC 28774 11.25 AM 10/08/24 12/06/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Gary Dennis Norton/ORC/828-891-7779/ Name, Address of Responsible Officiairritle/Phone and Fax Number Aubreyy L Deaver,PO Box 1407 Pisgah Forest NC Contacted 287681407//628-884-9772/8288848632 No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Operations & Maintenance 0 Records/Reports Facility ,Site Review Effluent/Receiving Waters Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Wanda P Frazier ARO WQ//828-296-4500 Ext.4662/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page # 1 NPDES yr/mo/day Inspection Type 3I NCO059439 I11 12I 10/08/24 I17 18H (cont.) Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) FACILITY DESCRIPTION: The Sapphire Lakes WWTP # 2 is a class I Biological (sand filter) system rated as a 0.0049 MGD wastewater treatment system with: (no septic tank on -site) 1000 gallon dosing tank with siphon bell; distribution manifold; 25' x 30' surface sand filter with 9 laterals of 4-inch diameter drilled pvc and 3/-inch diameter vertical vents; tablet chlorinator; 1000 gallon chlorine contact chamber; tablet dechlorinator; and concrete step cascade. Annual Average Flow: There is usually no discharge, unless it rains. Collection System: Consists of the gravity sewer collection of gray water from the individual septic tanks of 8 homes, serving 12 non -permanent residents, located on the Fairway Villas. Development: Sapphire Lakes has 1450 acres and is a private, second home community with golfing, tennis and swimming pool. There is a total of 1000 acres with 590 lots, 84 multi-family/villa units, 8 guest quarters, and an 80 seat clubhouse. WWTP # 1 treats the wastewater from these connections. Sludge Management: Commercial hauler to the City of Brevard's WWTP. PERMIT / INSPECTION / LOG: A review of the files indicates that the last compliance evaluation inspection was conducted on 2-14-2007 by Wanda Frazier. The permit expires on 7-31-2013. Please request a permit renewal 6 months prior to expiration. A renewal notice will be mailed as a reminder. - OPERATIONS AND MAINTENANCE / EFFLUENT / SUMMARY: Mr. Aubrey Deaver and MR. Mike Walker assisted in the inspection. It appears that this facility is being properly operated and maintained. There was no discharge at the time of the inspection. Due to seasonal residents and the small volume wastewater, a discharge usually does not occur, unless there is a rain event. SYSTEM PERFORMANCE ANNUAL REPORT: The 2009 System Performance Annual Report was received by the Division on 2-15-2010. Page # 2 Permit: NCO059439 Owner - Facility: Sapphire Lakes Plant WVVTP #2 Inspection Date: 08/24/2010 Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new application? 0 ❑ ■ ❑ Is the facility as described in the permit? ■ ❑ n n # Are there any special conditions for the permit? n ❑ ■ - - Is access to the plant site restricted to the general public? ■ n n n Is the inspector granted access to all areas for inspection? ■ n n n Comment: Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? ■ n n n Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge n n ■ n Judge, and other that are applicable? Comment: Sand filter system. Sand Filters (Low rate) Yes No NA NE (If pumps are used) Is an audible and visible alarm Present and operational? n n ■ n Is the distribution box level and watertight? n n ■ n Is sand filter free of ponding? ■ n n n Is the sand filter effluent re -circulated at a valid ratio? n n ■ n # Is the sand filter surface free of algae or excessive vegetation? ■ n ❑ n # Is the sand filter effluent re -circulated at a valid ratio? (Approximately 3 to 1) n n ■ n Comment: Disinfection -Tablet Yes No NA NE Are tablet chlorinators operational? ■ 0 El 0 Are the tablets the proper size and type? ■ n n n Number of tubes in use? 2 Is the level of chlorine residual acceptable? ❑ n ❑ ■ Is the contact chamber free of growth, or sludge buildup? ■ n n n Is there chlorine residual prior to de -chlorination? n n n ■ Comment: De -chlorination Yes No NA NE Type of system ? Tablet Is the feed ratio proportional to chlorine amount (1 to 1)? n n ■ n Page # 3 Permit: NC0059439 Owner - Facility: Sapphire Lakes Plant WWTP #2 Inspection Date: 08/24/2010 Inspection Type: Compliance Evaluation De -chlorination Yes No NA NE Is storage appropriate for cylinders? n n ■ n # Is de -chlorination substance stored away from chlorine containers? n n ■ n Comment: Are the tablets the proper size and type? ■ n n n Are tablet de -chlorinators operational? ■ n n n Number of tubes in use? 1 Comment: Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? ■ n n n Are the receiving water free of foam other than trace amounts and other debris? ■ n n n If effluent (diffuser pipes are required) are they operating properly? n n ■ n Comment: Page # 4 j6► m u vvater bervice, inc. P. O. Box 1407 Pisgah Forest, NC 28768 Phone (828) 884-9772 fax (828) 884-8632 { NOTICE Annual Performance Report Wastewater Treatment Svstemsil- j FEB 17 2010 I: i WATER QUALITY SECTION f ASNEVILLE REGiCi AL OFFICE On July 20, 1999, the North Carolina General Assembly ratified House Bill 1160, the Clean Water Act of 1999, which placed significant new reporting requirements on those entities that own or operate wastewater treatment and collection systems. Specific items included: 1. A Spill Response Plan 2. Sewer Collection System Operation & Maintenance Plan 3. Annual Performance Report These new requirements became effective October 1, 1999. This law was established to provide a mechanism for public oversight (and hopefully, to instill public confidence) in owners and operators of wastewater treatment systems and in their efforts to protect the waters of the state. We are pleased to announce that the Annual Performance Report for your wastewater treatment and sewer line collection system is now available for review. A copy of the report is available to interested persons by contacting the office at (828) 884-9772. A&D Water Services, Inc. is pleased to be a part of this on -going environmental protection effort. Sincerely, Aubrey OME D FEB 152010 QU-AU Y POINT SOURCE BRANCH 1 I�IrI®uu�r��uuu�rinru�ruu�rlrr., . llrl minim uuuuu�ruu�nruuu�iuumruu uruuuuuuiminim nruuuu IN A & D Water Service, Inc. uuuuuuuuuu�mu�ruuuuuuu�nmuuuuinmu�muuiruuuu�ririnr�r�rimimimu�nririeuiminmuw.uuuimmm�imuummimuuuu P. O. Box 1407 Pisgah Forest, NC 28768 Phone (828) 884-9772 Fax (828) 884-8632 Annual Wastewater Treatment System Performance Report for Sapphire Lakes Wastewater Treatment System for the Operating Period January thru December - 2009 Preface On July 20, 1999, the North Carolina General Assembly ratified House Bill 1160, the Clean Water Act of 1999, which placed significant new reporting requirements on those entities that own or operate wastewater treatment and collection systems. Specific items included: 1. A Spill Response Plan 2. Sewer Collection System Operation & Maintenance Plan 3. Annual Performance Report These new requirements became effective October 1, 1999. This report is designed to meet the minimum requirements for the Annual Performance Report established by the North Carolina Department of Environment and Natural Resources (DENR) as set forth in their guidance document dated October 19, 1999. This law was established to provide a mechanism for public oversight (and hopefully, to instill public confidence) in owners and operators of wastewater treatment systems and in their efforts to ;protect the waters of the state. L' General Information Facility/System Name: Responsible Entity: Person(s) in Charge/Contact: Applicable Permits: Sapphire Lakes WWTP Transylvania County A&D Water Services, Inc. Aubrey Deaver - Owner Gary Norton - Operator -in -Responsible Charge (ORC) NPDES # NCO059421 Description of Treatment Process, Collection System and Facilities Served: Treatment Process - The system operates two (2) treatment facilities: The larger treatment facility (NPDES # NCO059421) is.a typical extended aeration process capable of treating 25,000 gallons per day (gpd) with tablet chlorine disinfection. The treated effluent is discharged into the Idorsepasture River, classified Class C waters, in the Savannah River Basin. The smaller treatment facility (NPDES # NC0059439) is a typical surface sand filter capable of treating 4,900 gallons per day (gpd) with tablet chlorine disinfection. The treated effluent is discharged into James Creek, classified Class C waters, in the Savannah River Basin. Collection System - The main collection system is a standard gravity design with 8-inch diameter pipe and pre -cast manholes. The system has one duplex lift station with small diameter force main in service. The system has a Spill Response Plan and an Operation and Maintenance Plan for the collection system. Facilities Served - The larger facility serves most of the developed area. The sand filter unit serves a portion of Fairway Villas only. II. WWTP Performance The WWTP received Notices of Violation for failure to provide continuous monitoring in February and March. The situation was `operator reporting' error and easily corrected. We take pride in our efforts to protect the local environment and the quality of the waters in our streams. M. Notification A letter advising of the availability of this report will be mailed to each resident. A copy of this report is available to interested persons in the offices of: A&D Water Services, Inc. P.O. Box 1407 Pisgah Forest, NC 28768 2 or by contacting th:..�fice at 828-884-9772. As required, three copies of this report is being provided to NC DENR Readers who have questions or desire detailed information are invited to contact Aubrey Deaver at our offices. V. Certification I certify that under penalty of law that this report is complete and accurate to the best of my knowledge. Aubrey Deaver, Owner Date This report prepared by: Tom Kilpatrick P.O. Box 679 Etowah, NC 28729 Phone: (828) 8904810 February 7, 2010 Filename: CADocuments and Settings\DEAVER\Desktop\Tom's Documents%apphire LakeslAPR Sapphire Lakes'09.wpd 3 1■I■1■1■1■1■1■Imin 1111■I■MI■I■1■1■1■1■1■a■uuiu■i■i■,■i■um■r■i■�■i■i■i■uu A & D Water Service, Inc. uur■uuuuuuuuuui■i■i■uuur■r■uuuiriiiu■r■uuuuuuuuuui■uuuuinnmuw■uw■uuuuuuuui■uuuuuuuuuuuu P. O. Box 1407 Pisgah Forest, NC 28768 Phone (828) 884-9772 Fax (828) 884-8632 Annual Wastewater Treatment System Performance Report for Sapphire Lakes Wastewater Treatment System for the Operating Period January thru December - 200$ `;?" ;l I Y Preface On July 20, 1999, the North Carolina General Assembly ratified House Bill 1160, the Clean Water Act of 1999, which placed significant new reporting requirements on those entities that own or operate wastewater treatment and collection systems. Specific items included: 1. A Spill Response Plan 2. Sewer Collection System Operation & Maintenance Plan 3. Annual Performance Report These new requirements became effective October 1, 1999. This report is designed to meet the minimum requirements for the Annual Performance Report established by the North Carolina Department of Environment and Natural Resources (DENR) as set forth in their guidance document dated October 19, 1999. This law was established to provide a mechanism for public oversight (and hopefully, to instill public confidence) in owners and operators of wastewater treatment systems and in their efforts to protect the waters of the state. C V 70 k vi, MAY 2 9 2009 ®FINK - '`✓/%R QUALITY POINT SOURCE BRANCH I. General Information Facility/System Name: Responsible Entity: Person(s) in Charge/Contact: Applicable Permits: Sa ire-Lakes-W-WTP Transylvania County A&D Water Services, Inc. Aubrey Deaver - Owner Wesley Royal - Operator -in -Responsible Charge (ORC) NPDES # NC0059421 NPDES,00 4�395 Description of Treatment Process, Collection System and Facilities Served: Treatment Process - The system operates two (2) treatment facilities: The larger treatment facility (NPDES # NC0059421) is a typical extended aeration process capable of treating 25,000 gallons per day (gpd) with tablet chlorine disinfection. The treated effluent is discharged into the Horsepasture River, classified Class C waters, in the Savannah River Basin. The smaller treatment facility (NPDES # NC0059439) is a typical surface sand filter capable of treating 4,900 gallons per day (gpd) with tablet chlorine disinfection. The treated effluent is discharged into James Creek, classified Class C waters, in the Savannah River Basin. Collection System - The main collection system is a standard gravity design with 8-inch diameter pipe and pre -cast manholes. The system has one duplex lift station with small diameter force main in service. The system has a Spill Response Plan and an Operation and Maintenance Plan for the collection system. Facilities Served - The larger facility serves most of the developed area. The sand filter unit serves a portion of Fairway Villas only. H. WWTP Performance The WWTP was in compliance with all NPDES permit parameters for the period. We take pride in our efforts to protect the local environment and the quality of the waters in our streams. III. Notification A letter advising of the availability of this report will be mailed to each resident. A copy of this report is available to interested persons in the offices of: A&D Water Services, Inc. P.O. Box 1407 Pisgah Forest, NC 28768 or by contacting the office at 828-884-9772. As required, three copies of this report is being provided to NC DENR Readers who have questions or desire detailed information are invited to contact Aubrey Deaver at our offices. V. Certification I certify that under penalty of law that this report is complete and accurate to the best of my knowledge. eaver, Owner Date/ This report prepared by: Tom Kilpatrick P.O. Box 679 Etowah, NC 28729 Phone: (828) 890-4810 March 16, 2009 Filename: CADocuments and SettingsDEAVEMesktoffom's DocumentslSapphire Lakes\APR Sapphire Lakes'08.wpd CERTIFIED MAIL 7007 0710 0000 5376 7662 RETURN RECEIPT REQUESTED A & D Water Service Mr. Aubrey L. Deaver PO Box 1407 Pisgah Forest, NC 28768-1407 Dear Mr. Deaver: Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources j. ,f•��.�'r� ,:.�.;r'-,�:_`.J..._W_...�..Division•of•�UaterQu3lity...,.y ' —r11'n October 22, 2008 } OCT 2 3 2008 U/ E Subject: NOTICE OF VIOLATION - NOV- 2008- LR- 0071 Sapphire Lakes Plant #2 WWTP — NCO059439 Transylvania County This is to inform you that the Division of Water Quality has not received your monthly monitoring report for August 2008 after the required reporting date. This is in violation of Part II, Condition D(2) of the NPDES permit, as well as 15A NCAC 2B .506(a), which requires the submittal of Discharge Monitoring Reports (DMR) no later than the thirtieth (301h) day following the reporting period. Failure to submit reports as required will subject the violator to the assessment of a civil penalty of up to $25,000 per violation. You will be considered noncompliant with the self -monitoring requirements of your NPDES permit until the report has been submitted. Please submit the April 2008 DMR report within 15 days of receipt of this notice if you have not yet submitted it. To prevent further action; please submit future monthly reports within.the above -mentioned timeframe to avoid further enforcement actions. You are also required to notify the Division each time mailing or phone numbers are changed which relate to your NPDES permit. The Division must take these steps because timely submittal of discharge monitoring reports is essential to the efficient operation of our water quality programs. We appreciate your assistance in this matter. If you have any questions about this letter or Discharge Monitoring Reports, please contact me at 919-807-6387. Sincerely, Bob Guerra Western Region NPDES Unit cc: ARO -_Surface Water Protection Supervisor Enforcement file Central Files NorthCarolina Naturally North Carolina Division of Water Quality 1617 Mail Service Center Raleigh, NC 27699-1617 Phone (919) 807-6300 Customer Service Internet: www.ncwiterguality.org Location: 512 N. Salisbury St. Raleigh, NC 27604 Fax (919) 807-6492 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer-50% Recycled/10% Post Consumer Paper July 24, 2Q.(l7� I I CERTIFIED MAIL 7002 3150 0003 7052 9561 RETURN RECEIPT REQUESTED Mr. Aubrey L. Deaver A & D Water Services, Inc. P.O. Box 1407 Pisgah Forest, NC 28768 Dear Mr. Deaver: Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Coleen H. Sullins, Director Division of Water Quality U JUL 2 7 2007 WATER QUALITY S— E� N r c 3HEVILLE REGICImm OFFI c --------.i ' Subject: NOTICE OF VIOLATION - NOW 2007- LR- OO Sapphire Lakes WWTP #2 WWTP NCO059439 Transylvania County This is to inform you that the Division of Water Quality has not received your monthly monitoring report for July 2007 after the required reporting date. This is in violation of Part II, Condition D(2) of the NPDES permit, as well as 15A NCAC 2B .506(a), which requires the submittal of Discharge Monitoring Reports no later than the thirtieth (30") day following the reporting period. Failure to submit reports as required will subject the violator to the assessment of a civil penalty of up to $25,000 per violation. You will be considered noncompliant with the self -monitoring requirements of your NPDES permit until the report has been submitted. Please submit the July 2007 DMR report within 10 days of receipt of this notice if you have not yet submitted it. To prevent further action, please submit future monthly reports within the above -mentioned timeframe to avoid further enforcement actions. The Division must take these steps because timely submittal of discharge monitoring reports is essential to the efficient operation of our water quality programs. We appreciate your assistance in this matter. If you have any questions about this letter or Discharge Monitoring Reports, please contact me at 919-733-5083, extension 539. Sincerely, 6y"&~ Bob Guerra Western Region NPDES Unit cc: rIJW _Asheville Surface Water Protection Supervisor Central Files Nose Carolina Mural!' North Carolina Division of Water Quality 1617 Mail Service Center Raleigh, NC 27699-1617 Phone (919) 733-5083 Customer Service Internet: h2o.enr.state.nc.us 512 N. Salisbury St. Raleigh, NC 27604 FAX (919) 733-0719 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer— 50% Recycled/10% Post Consumer Paper �WATfi Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources �- 3 Alan W. Klimek, P.E. Director Division. of Water Quality `r Asheville Regional Office SURFACE WATER PROTECTION SECTION. February 19, 2007 F L Mr. Aubrey L. Deaver A&D Water Service Inc. PO Box 1407 Pisgah Forest, NC 28768 SUBJECT: Compliance Evaluation Inspection Sapphire Lakes Plant WWTP #2 Permit number NCO059439 Transylvania County Dear Mr. Deaver: Enclosed please find a copy of the Compliance Evaluation Inspection form from the inspection conducted on February 14, 2007, The facility Was found to be in compliance With permit NC0059439. Please refer to the enclosed inspection report for additional observations and comments. If you or your staff have any questions, please call me at 828-296-4500 extension 4662. Sincerely, Wanda P. Frazier Environmental Specialist Enclosure cc .C.e.ntral Files Ag-evifle isles NorrthCarolina 2090 US Hwy 70, Swannanoa, NC 28778 Telephone: (828) 296-4500 Fax: (828) 299-7043 Customer Service 1 877 623-6748 United States Environmental Protection Agency Form Approved. E n /r, Washington, D.C. 20460 f /`1 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 I NJ 2 1 51 31 N00059439 111 121 07/02/14 117 18JLJC 191 SI 20I LJ L- Remarks 21111111111111111111111111111111111111111111111116 Inspection Work Days Facility Self -Monitoring Evaluation Rating 81 QA ------- -------------- ---- Reserved ---------- ---- ----- 67I 1.0 169 701 31 711 I 721 NJ 73I I 174 151 I I I I I I 180 L -L- Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) Sapphire Lakes Plant WWTP #2 01:55 PM 07/02/14 02/12/01 Exit Time/Date Permit Expiration Date 1600 US Hwy 64 W Sapphire NC 28774 02:05 PM 07/02/14 07/08/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Aubrey L Deaver, PO Box 1407 Pisgah Forest NC 28768//828-884-9772/8288848632 No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Operations & Maintenance ■ Records/Reports Self -Monitoring Program, Facility Site Review ® Effluent/Receiving Waters Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Wanda P Frazier (FARO WQ//828-296-4500 Ext.4662/ �GJ � Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page # 1 At NPDES yr/mo/day Inspection Type 1 3I NCO059439 I11 12I 07/02/19 I17 181_I Section D: Summary of Finding/Comments (Attach additional) LC of narrative and checklists as necessary) A review of the files indicates that the last compliance evaluation inspection was conducted on 11-17-2005 by Jim Reid. The permit expires on August 31, 2007, please request a permit renewal 6 months prior to expiration. There was no discharge during the time of the inspection. Angie McCall & Wesley'Royal, the contract operators, were on -site during the inspection. This facility appears to be well operated and maintained. The operators are doing a good job. Page # 2 'r, , '" Permit: NCO059439 Inspection Date: 02/14/2007 Owner - Facility: Sapphire Lakes Plant WWTP #2 Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new application? ❑ ❑ ■ ❑ Is the facility as described in the permit? ■ ❑ ❑ ❑ # Are there any special conditions for the permit? ❑ ■ ❑ ❑ Is access to the plant site restricted to the general public? ■ ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? ■ ❑ ❑ ❑ Comment: Septic Tank Yes No NA NE (If pumps are used) Is an audible and visual alarm operational?• ❑ 1-1 ■ ❑ Is septic tank pumped on a schedule? ■ ❑ ❑ ❑ Are pumps or syphons operating properly? ■ 11110 Are high and low water alarms operating properly? ❑ El ■ ❑ Comment: Sand Filters (Low rate) Yes No NA NE (If pumps are used) Is an audible and visible alarm Present and operational? ❑ ❑ ■ ❑ Is the distribution box level and watertight? ■ ❑ Is sand filter free of ponding? ■ ❑ ❑ ❑ Is the sand filter effluent re -circulated at a valid ratio? Cl ❑ ■ ❑ # Is the sand filter surface free of algae or excessive vegetation? ■ ❑ ❑ ❑ # Is the sand filter effluent re -circulated at a valid ratio? (Approximately 3 to 1) ❑ ❑ ■ ❑ Comment: Disinfection -Tablet Yes No NA NE Are tablet chlorinators operational? ■ ❑ ❑ ❑ Are the tablets the proper size and type? ® ❑ ❑ ❑ Number of tubes in use? 1 Is the level of chlorine residual acceptable? ■ ❑ ❑ ❑ Is the contact chamber free of growth, or sludge buildup? ■ ❑ ❑ ❑ Is there chlorine residual prior to de -chlorination? ■ ❑ ❑ ❑ Comment: Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? ■ ❑ ❑ ❑ Page # 3 Permit: NCO059439 Owner - Facility: Sapphire Lakes Plant WWTP #2 Inspection Date: 02/14/2007 Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge ❑ fl fl Judge, and other that are applicable? Comment: If Page # 4 O� 1JV.ATF Michael F. Easley, Governor ��-- R ,�1V�IIi�tn.,G,•,Ross Jr., Secretary \� QG North Carolina Departmen wronmenf end Natuial F�esoU'�Cesxi: rFan W. Klimet , P.E. Di eDivon q Water (�uafity 'A-he'villeRegion2k0ffice -• SURFACE WATER PROTECTION January 4, 2006 Mr. Ken Wheat Sapphire Lakes Utility Company Inc PO Box 130 Sapphire NC 28774 SUBJECT: November 17, 2005 Compliance Evaluation Inspection Sapphire Lakes Utility C pany Inc Sapphire Lakes WWTP ##2 Permit No: NC0059439 Transylvania County Dear Mr. Wheat: Enclosed please find a copy of the Compliance Evaluation Inspection form from. the inspection conducted on November 17, 2005. The Compliance Evaluation Inspection was conducted by James R Reid and Starr Silvis of the Asheville Regional Office. The facility was found to be in Compliance with permit NC0059439. . Please refer to the enclosed inspection report for additional observations and comments. If there are questions, please call me at 828-296-4500 Ext.4651. Sincerely, �7 ?Ja�m�esRReid Enclosure cc: Robert E. Orr, ORC Central Files Asbheville- Files- N nehCarolina �atur�rlly 2090 U.S. Highway 70, Swannanoa, NC 28778 Telephone: (828) 296-4500 Fax: (828) 299-7043 Customer Service 1 877 623-6748 United States Environmental Protection Agency Form Approved.. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 I NI 2 15I 31 td00059439 12I 05/1/l117 19I SI 20III1 ICI Remarks 21I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I Lj6 Inspection Work Days Facility Self -Monitoring Evaluation Rating 131 QA -----------------Reserved -------- --------- --- 67I 169 70131 711 I 72 I y I 73 LLJ 74 751 I I I I I I 180 L_t� Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) Sapphire Lakes P:iVTP #2 02:40 PM 05/11/17 02/12/01 Exit Time/Date Permit Expiration Date 1600 US Hwy 64 W Sapphire NC 28774 02:55 PM 05/11/17 07/08/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Robert E. Orr/0RC/828-884-9772/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Darnall W Boyd,PO Box 130 Sapphire NC 28774//828-966-9200/8289664068 No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit ® Operations & Maintenance E Self -Monitoring Program E Facility Site Review Section D: Summary of Find in /Comments Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date James R Reid ARO wQ//828-296-4500 Ext.4651/ �— �/— 06' Starr Si' ivis ,� ` ARO `:aQ//828-296-4500/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers e/ f/Da I l ®IlJ (.� •�L�ii, 7 ` U EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page # 1 NPDES yr/mo/day ;nspection Type 3I `100059439 1 11 12I 05/11/17 I17 181;.I Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Filter bed was adequately maintained. The facility did not appear to have discharged in a long period of time. Page # 2 Permit: NCO059439 Owner - Facility: Sapphire Lakes VW TP #2 Inspection Date: 11/17/2005 Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? ■ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge ■ ❑ n n Judge, and other that are applicable? Comment: Permit Yes No NA NE (if the present permit expires in 6 months or less). Has the permittee submitted a new application? ■ n n n Is the facility as described in the permit? ■ O n n # Are there any special conditions for the permit? n ■ n n Is access to the plant site restricted to the general public? ■ n n n Is the inspector granted access to all areas for inspection? ■ fl ❑ ❑ Comment: Page # 3