October 2, 2020
Mr. Andrew Miller
1725 Stonefield Lane
Clemmons, NC 27012
Subject: System Startup Inspection
Miller SFR - Wastewater Treatment & Irrigation System
Permit No. WQ0040626
Forsyth County
Dear Mr. Miller,
This letter is follow-up on the startup inspection of the wastewater irrigation system serving the new residence
located at 1725 Stonefield Ln. under Permit No. WQ0040626. The inspection of the wastewater irrigation
system was conducted on October 1, 2020 by Division staff member Patrick Mitchell. All system components
were found to be present and appeared to be functioning properly at the time of the inspection. The Division
has also received the Engineering Certification from Mr. Jack Harman, PE. The wastewater irrigation system
is operational and can be put in to use when needed. However, please address the following items within
30 days of receipt of this letter:
There are areas of soil disturbance present in the irrigation field with ruts following system installation.
Please smooth out these areas by hand to prevent compaction. Replace topsoil with the onsite topsoil
spoil pile where necessary to create a uniform landscape that does not collect and hold water. Also,
please establish ground cover in disturbed areas to prevent erosion and runoff from occurring.
The final grading has not been completed around the wastewater treatment system. Please ensure that
all tank risers have a minimum six (6) inches of rise above the finished grade.
A follow-up inspection will be conducted to ensure the above listed items are completed. Please see the
attached inspection report for additional observations and comments. If you have any questions concerning
this letter, please contact Patrick Mitchell or me at the letterhead address or phone number, or by email at
patrick.mitchell@ncdenr.gov or Ion. snidernncdenr.gov.
Sincerely,
IL—
DocuSigned by:
oti -T S,udcr
14 49 225 94EA
Lon m er, Regional Supervisor
Water Quality Regional Operations Section
Division of Water Resources, NCDEQ — WSRO
enc: Inspection Report
cc: Jack Harman, PE (Electronic Copy)
Forsyth County Environmental Health (Electronic Copy)
Laserfiche File WQ0040626,
WSRO Electronic Files
North Carolina Department of Environmental Quality I Division of Water Resources
Winston-Salem Regional Office 1 450 West Hanes Mill Road, Suite 3001 Winston-Salem, North Carolina 27105
336.776.9800
Compliance Inspection Report
Permit: WQ0040626 Effective: 06/13/19 Expiration: 03/31/25 Owner: Andrew T Miller
SOC: Effective: Expiration: Facility: 1725 Stonefield Ln. SFR
County: Forsyth 1725 Stonefield Ln
Region: Winston-Salem
Clemmons NC 27012
Contact Person: Andrew T Miller Title: Phone:
Directions to Facility:
System Classifications:
Primary ORC: AQUA
Secondary ORC(s):
On -Site Representative(s):
Related Permits:
Inspection Date: 10/01/2020
Primary Inspector: Patrick Mitchell
Secondary Inspector(s):
Certification:
Phone:
Entry Time 11:25AM Exit Time: 01:OOPM
Phone: 336-776-9698
Caitlin Caudle
Reason for Inspection: Other Inspection Type: Compliance Evaluation
Permit Inspection Type: Single -Family Residence Wastewater Irrigation
Facility Status: ❑ Compliant ❑ Not Compliant Neither
Question Areas:
Miscellaneous Questions
(See attachment summary)
Permit: WQ0040626 Owner- Facility: Andrew T Miller
Inspection Date: 10/01/2020 Inspection Type : Compliance Evaluation Reason for Visit: Other
Inspection Summary:
On October 1, 2020 a system startup inspection was conducted at the subject facility. The system has not been put inuse
yet. The following persons accompanied Division staff on the inspection: Andrew Miller; Jack Harman, PE; Todd with AQUA;
and Frank with Transou Septic. The purpose of this inspection was to verify system installation and operation. On October 1,
2020 the Division received a final Engineer Certification for the subject system from Mr. Harman, PE.
The system components were found to be present and appeared to be operational at the time of inspection. Only minor
changes from the approved plans were observed and are listed below:
- Advantex treatment unit was installed opposite side of the recirculating pump tank from that shown on the approved plans.
See attached field sketch map.
- The recirculating pump tank has a 30 GPM pump installed instead of a 20 GPM pump.
- The storage -dose pump tank has a 20 GPM pump installed instead of a 16 GPM pump.
While the system has been certified by the design PE and was found to be operational, the items listed below require action
and follow-up.
1. There were disturbed areas (e.g. ruts and scraped topsoil) present in the spray field resulting from system installation.
These areas need to be repaired carefully to prevent compaction. The Permittee (Mr. Miller)showed Division staff a stockpile
of onsite topsoil that is present. This topsoil is to be used to fill in low areas as needed to create a final uniform topography
that will not collect and hold water in or adjacent to the spray patterns.
2. The disturbed areas also need to have a ground cover established to prevent erosion and runoff from occurring.
3. The final grading has not been completed around the wastewater treatment system due to recent rains. The minimum
height for tank risers is 6 inches above final grade. The grading should be done to shed water from around the tanks and to
ensure a minimum 6 inches above grade for riser lids. If necessary, additional riser section should be added to achieve this.
OTHER NOTES:
Reportedly the floats have been set to dose the system within the specs in the approved plan.
Three of the spray heads (heads #4, #5 & #8) did not operate properly when initially tested during inspection. Contractors
cleaned nozzles for each head and tested to demonstrate operating properly. Reported clogging was due to shavings and
minor construction debris being flushed out of the system.
- Requested homeowner closely monitor spray heads to ensure no more clogs result and cleanout as necessary to
prevent wastewater runoff and discharges.
- Particular attention is needed for spray heads #3 and #4 which are immediately upslope from a small rill leading to a
drainageway which can act as a conduit to surface water discharge.
The access restriction fence was found to be compete, all except the small section closes to the home. This area is
remaining open until construction activities are completed to allow access for work. Permittee plans to install an opening
that can be easily lowered to allow maintenance access to spray field.
Discussed future routine compliance inspections conducted by the Division and associated records to be maintained for
the system. Copy of permit forwarded to Permittee for records.
Reportedly the Advantex manufacturer requires a certified ORC to maintain product warranty. AQUA has been obtained by
the Permittee to serve as the ORC for the system with a minimum of once per year ORC visitation frequency.
The system has telemetry installed. AQUA plans to monitor the system remotely and make any operational adjustments
necessary from data obtained. Part of the monitoring reportedly includes UV disinfection system monitoring. Bulbs planned
for replacement at minimum 1/yr.
AQUA will maintain operational record logs that can be obtained for review.
*FOLLOW-UP INSPECTION IS REQUIRED TO ENSURE ACTION ITEMS ARE COMPLETED.
IV
to
0
Lq
0
V 1
0
QD
qq
0
C) m
�>
Z m
00 z
-Q
o
0
CJ1 CY)
rn �
m
w
0
O
�1v
�v
a
o�
112" SCH 40
8UR
°ova
s� �, C
N, y� �J
e. y
kC' ' oo so 90 2c 4
vn _
co
a' c
m
n m
--I o
00
Dr-o
v
CSC
40 p �p r
t'1
_ ° •1
�j JCp �J o co 'J
0) w
m 0
3 -a ���o
V) ooDo
�+ OMO Z<mm
+ ' x'— m coon0 0 ���o
1— V m �m�
NJ
-A�
North Carolina Department of Environmental Quality
Division of Water Resources
Water Quality Section
NON -DISCHARGE COMPLIANCE INSPECTION REPORT
SINGLE FAMILY RESIDENCE — WASTEWATER IRRIGATION
General Information
Permittee: Andrew & Holly Miller
Permit No.: W00040626
Issuance Date: _ June 13, 2019
Other Contact: Jack Harman PE
Location Address- 1725 Stonefield.Ln.. Clemmons
Telephone No.: 336-399-8674
County: Forth
Expiration Date: March 31 2025
Telephone No.: 919-818-2077
.-� P&,
r
Reason for Inspection
❑ ROUTINE ❑ FOLLOW-UP ❑ COMPLAINT ❑ PERMITTING ® OTHER: Initial Startup Inspection
Comments (attach additional pages as necessary)
/ 5��� y 4. -if
s�)
Is a follow-up inspection necessa� Yes ) ❑ No n ce el f rw_11r . � Y C/ .�
Primary Inspector: P. Mitchell
Date of Inspection: October 1, 2020
Secondary Inspector: C. Caudle
Entry Time: Z
ExitTime:
Non -Discharge Compliance Inspection Report
Record Keeping +
Is current permit available upon request?�J��lv�t<1
Is a copy of the system plans available? &Ar, AA,91 er,
Is estimated flow rate (estimated by # of bedrooms, # of residents, or water meter
readings) less than permitted flow design?
Does Perm ittee have an inspection log (date & time of monthly system inspection,
observations noted, any maintenance or repairs)?
Are septic tank pumping receipts available?
Date the septic tank was last pumped? NA
Any complaints regarding the facility in the last 12 months?
comments: System installation & certification, not in use yet.
Yes
❑ No
®NA
❑ NE
❑ Yes
❑ No
® NA
❑ NE
❑ Yes
❑ No
® NA
❑ NE
❑ Yes
❑ No
® NA
❑ NE
❑ Yes
❑ No
® NA
❑ NE
❑ Yes ❑ No ® NA ❑ NE
Septic Tank 1,000 gal. S.T. G L
/ 1
Are tanks properly located?� Yes ❑ No ❑ NA ❑ NE
Does septic tank have a filter? Yes ❑ No ❑ NA ❑ NE
Is septic tank checked and pumped as needed? ❑ Yes ❑ No ® NA ❑ NE
Comments:
gat. Recirculation Tank wl Z9- Pit PUMP 7 3c�a
Pump Tank, Pumas, Controls, & Alarms 3,500 gal. Storage -Dose Tank w/ 46-GPM-Pump �F
Are all pumps present and operational? 9Yes ❑ No ❑ NA ❑ NE
Are the floats and controls operable? 'Yes ❑ No ❑ NA ❑ NE
Are alarms (audible and visible) present and operational? gYes ❑ No ❑ NA ❑ NE
Are alarms properly located (where it can be seen & heard)? Yes ❑ No ❑ NA ❑ NE
If required, is a rain sensor present and operational? Yes ❑ No ❑ NA ❑ NE
Comments:
Treatment
Are treatment facilities consistent with those outlined in the current permit?
Yes
❑ No
❑ NA
❑ NE
Do all treatment units appear to be operational? If no, note below.
Kyes
❑ No
❑ NA
❑ NE
Free of bypass lines or structures?
x Yes
❑ No
❑ NA
❑ NE
What type of treatment unit is being used (i.e., sand filter, peat filter, advantex, etc.)?Advantex AX-20 Treatment Filter Pod
Does this treatment unit require an operator? If so, note who below.
Yes
❑ No
❑ NA
❑ NE
Page 2 of 4
N
Non -Discharge Compliance Inspection Report
Treatment Continued
Are the treatment units subsurface?
❑ Yes
No
❑ NA
❑ NE
Is the treatment unit free of ponding, algae, or excessive vegetation?
❑ Yes
❑ No
NA
❑ NE
Is the treatment unit effluent re -circulated at a valid ratio?
Yes
❑ No
❑ NA
❑ NE
Is the distribution box level and watertight?
Xyes
❑ No
❑ NA
❑ NE
Comments:
Treatment Disinfection UV Disinfection Unit
Is the disinfection system accessible, maintained and checked as needed?
Yes
❑ No
❑ NA
❑ NE
If tablets are used, are tablets present in cylinder(s), proper size and type? ❑ Yes
❑ No
® NA
❑ NE
Is contact chamber free of sludge, solids, and growth?
Yes
❑ No
❑ NA
❑ NE
If UV is used, is UV intensity adequate? Are UV bulbs clean?
Yes
❑ No
❑ NA
❑ NE
Are extra bulbs available?
Yes
❑ No
ElNA
❑ NE
Comments:
1
End Use Irrieation
Are buffers adequate?
b<Yes
❑ No
❑ NA
❑ NE
Is access restricted by a fence with at least two strands of ire?
'Yes
❑ No
❑ NA
❑ NE
Is the cover crop acceptable?
❑ Yes
No
❑ NA
❑ NE
Are application rates adhered to? 0.3 in./hr. & 17.27 in./yr.
❑ Yes
❑ No
® NA
❑ NE
Site adequate, no evidence of runoff, ponding, or limiting slopes?
❑ Yes
❑ No
® NA
❑ NE
Is the acreage specified in the permit being utilized?
❑ Yes
❑ No
® NA
❑ NE
Are spray heads operational? 4 y
9Yes
XNo
❑ NA
❑ NE
How many spray heads are present? 8 (0.35 ac.)
Are any wells located nearby?
If so, how close? (check one) ❑ Inside the CB
Are welts at least 100' from the septic tank?
Is municipal water available in the area?
Comments.
❑ Yes ❑ No ® NA ❑ NE
❑ Within 250' of the CB ® Greater than 250' from the CB
❑ Yes ❑ No 5;�NA ❑ NE
9 Yes ❑ No ❑ NA ❑ NE
Page 3 of 4
Non -Discharge Compliance Inspection Report
Additional Comments and/or Sketch
W%- NG ON Y
.APt EN _ .E
'k SEE ILA 4 �a 7-98-
\ 'r" 7% -
�� 7
7
GGED SUI
ISFF4WuW ~%
D SF SPRAY C
lb SF MAPOP % 1
1
~Y H #a
I I
-7W
SpfiAYI %fie .._.:e776
Page 4 of 4