Loading...
HomeMy WebLinkAboutWQ0041935_Application (FTSE)_20200831State of North Carolina DWR Department of Environmental Quality Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Dlvlsion of Water Resources FTA 04-I6 & SUPPORTING DOCUMENTATION r iApplication Number: U0 � 3 S {to be by DWR) -3 All items must be completed or the application will be returned I. APPLICANT INFORMATION: 1. Applicant's name: 3921 S Miami LLC (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ® Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State.:County ❑ Municipal ❑ Other 3. Signature authority's name: Michael A. Hinderliter per 15A NCAC 02T .0106Ib} Title: Manaeer 4. Applicant's mailing address: 2435 S. Alston Avenue rr , �L City: Durham State: NC Zip: 212L< � � � f t � C C • 0 � � 5. Applicant's contact information: t Phone number: (919) 544-4140 Email Address: michael urbanim ort.com IL PROJECT INFORMATION: 1. Project name: 3921 S. Miami Blvd Building Expansion 2. AppIication/Project status: ® Proposed (New p (N Permit) ❑Existing Permit/Project �s u If a modification, provide the existing permit number: WQ00, and issued date: a If new construction but part of a master plan, provide the existing permit number: WQ00 C` 4 3. County where project is located: Durham M ,o 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.90743 Longitude:-78.84962 5: 5. Parcel ID (if applicable): 157347 Cn (or Parcel ID to closest downstream sewer) °A .� w CS III. CONSULTANT INFORMATION: C? I . Professional Engineer: David L. Dunn License Number: 15395 Z Firm: Bass. Nixon & Kennedy. Inc. Mailing address: 6310 Chanel Hill Rd., Suite 250 City: Raleigh Sate: NC Zip: 27607- Phone number: (919) 851-4422 Email Address: david-dunn(@,bnkinc.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Triangle Wastewater Treatment Plant Permit Number: NCO026051 Owner Name: Durham County V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): WQUnknown Downstream (Receiving) Sewer Size: 12 inch y_stem Wide Collcclion System Pen -nit Number(s (if applicable]: WQCS00038 Owner Name(s): Durham Count FORM: FTA 04-16 Pagel of 5 VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑No ®NIA 2. If the Applicant is a Developer of lots to be sold, has a Develop"'s Operatio al Agreement (FORM: DEV) been attached? ❑ Yes [-]No ®NSA 3. If the Applicant is a Home -Property Owners' Association, has an x:rational Atreement (FQ y: HOAR been attached? ❑ Yes ❑No ®N;'A 4. Origin of wastewater: (check all that apply): ❑ Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motels ❑ School ' preschool:' day care ❑ Medical! dentaI:: veterinary facilities ❑ Swimming Pool iClubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ® Businesses!' offices factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater: 100 % Domestic?Commercial % Commercial % Industrial (See 15A NCAC 02'1..0103(20I) bIs there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Hasa flow reduction been approved under 15A NCAC 02T .0I 1 ? ❑ Yes ®No If yes, provide a cony of flow reduction apuroval letter 7. Summarize wastewater generated by project: Establishment Type (see 02T.0I 140 Daily Design Flow .,b No. of Units Flow Warehouse 100 gal/loading bay 5 500 GAD General Business/Office 25 gal/employee/shift 175 4,375 GPD gau GPD gall GPD gall GPD gall GPD Total 4,875 GPD a See 15A NCAC 02T _01 14fb), (d), (e) f 1) andheJ(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in 6.5. 42A-4). b Per 15A NCAC 02T .0I 14(c), design flow rates for establishments not identified [in table 15 A NCAC .02T.0114] shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 4.875 GPD (per 15A NCAC 021.0114) Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: - ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8 351.41 PVC D Section lI & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: K A 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: - 3. Design flow of the pump station: millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): gallons per minute at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material N;'A 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(L): ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B); Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): S It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(f)): I. Does the project comply with all separations found in 15A NCAC 02T .0305(1) & { 15A NCAC 02T.0305(t) contains minimum senarations that chill he nrnvuterr Pnr cnu,Pr evo ® Yes ❑ No Setback Parameter* Separation Required Storm sewers and other utilities not listed below vertical 24 inches Water mains vertical -water over sewer including in benched trenches 18 inches Water mains horizontal 10 feet Reclaimed water lines vertical - reclaimed over sewer 18 inches Reclaimed water lines horizontal - reclaimed over sewer 2 feet **Any private or public water supply source, including any wells, WS-1 waters of Class I or Class II impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water or tide elevation and wetlands see item IX.2 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet -Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage s stems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade vertical 36 inches D 15A NCAC 02T.0305(c) contains alternatives where separations in 02T.03050 cannot be achieved. **Stream classifications can be identified using the Division's NC Surface Water Classificalions_webpuge ➢ If noncompliance with 02T.0305 (o nrJ1,,h see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ❑ Yes ❑ No ® N;'A Seethe Division's draft separation requirements for situations where separation cannot be meet ➢ No variance is required if the alternative design criteria specified is utilized in design and construction As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ❑ Yes ❑ No ® N.--'A This would include Trout Buffered Streams per 15,E NCAC 213.0202 4. Does the project require coverage/authorization under a 404 Nationwide or ❑ Yes ® No individual permits or 401 Water Quality Certifications? Information can be obtained from the 401 & Buffer Permittin , Branch 5. Does project comply with 15A NCAC 02T.0105(c)L(s) (additional permits. -certifications)? ®Yes ❑ No Per 15A NCAC QTQT.0105(c)i6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, e(c.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 021t',0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes ® No ❑ N;'A ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of X. CERTIFICATIONS: 1. Does the submitted system comply with 15A. NCAC 02T, gn Crit the Minimum Desieria for the Permittin of Pump stations and -Force Mainsilatest versionl, and the Gravity Sewer Minimum Design Crileria {latest vcrsi as applicable? ® Yes ❑ No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the re uest is re vired prior to submittal orthe Fast Track Application and supporting documents. 2. Professional Engineer's Certification: 1, ���' t J 1. - t�`"• r� attest that this application for (Professional Engineer's name from Application Item II1,1.) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to he consistent with the proposed design. NOTE In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: 3. Applicant's Certification per 15A NCAC 02T .0106(b): T ........... ....... _...... ... M1111py� i GAIN 11 ES81 �''s.= z a� SEP►L,19► 7 '- 15395 31. G.. attest that this application for has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE In accordance with General Statutes 143-215.6A and 143 215 6f3, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed SI0,000 as well as civil penalties up to $25,000 per violation. Signature: eo Date: FORM: FTA 04- l 6 Page 5 of 5 State of North Carolina Department of Environmental Quality Division of Water Resources Ilk;.,i„#, „R WoLn P ; , , Flow Tracldng for Sewer Extension Applications (FTSE 10-18) Entity Requesting Allocation: 3921 S Miami, LLC Project Name for which flow is being requested: 3921 S. Miami Blvd Building Ex ion More tkan one ME may be required for a single project if the owner of the t3 R P is not responsible for all pum p stations along the route of the proposed wastewater f Jmw. 1. Complete this section only if you are the owner of the wastewater treatment plant a. WWTP Facility Name: Triangle Wastewater Treatment Plant b. WWTP Facility Permit #: NCO026051 c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the WWTP e. WWTI' facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used All flows are In MGD 12 1.798 3.562 0.004875 5.365 44.7 11. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) Design Average Pump Pump Daily Station Station Firm Flow" (Name or Permit Capacity, • (Firm / pfl, Number) No. MGD MGD Stirruplron 6.50 2.60 (B) (C) (D)-(B+C) (E)-(A-D) Approx. Obligated, Total Current Not Yet Current Flow Avg, Daily Tributary Plus Flow, Daily Flow, Obligated Available MGD MGD Flow Capacity*** 1.142 0.459 1.601 0.999 The Firm Capacity (design flow) of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. " Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5, per Section 2.02(A)(4)(c) of the Minimum Design Criteria. *" A A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is 5 0. Downstream Facility Name (Sewer): Durham County Sewer W Downstream Permit Number; WQCS00038 Page 1 of 6 FTSE 10-18 111. Certification Statement: 1 `4d 4-Anlo_ 'Dx' I { certify to the best of my knowledge that the addition of the volwn'�'of wastewater"Ito be tted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and U plus all attached planning assessment addendum for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. Signing Of ctat Signature Q ' Dato �4 Title of Page 2 of 6 FTSE 10-18 SOSID: 1745975 Date Filed: 8/31/2018 9:12:00 AM Elaine F. Marshall North Carolina Secretary of State C2018 242 00590 Limited Liability Company ARTICLES OF ORGANIZATION OF 3921 S MIA11iI, LLC Pursuant to §57D of the General Statutes of North Carolina, the undersigned does hereby submit these Articles of Organization for the purpose of forming a limited liability company. I . The name of the limited liability company is: 3921 S MIAMI, LLC 2. The limited liability company is not to dissolve by a specific date, and its duration shall be perpetual. 3. The name and address of the organizer executing these articles of organization is as follows: MICHAEL A. HINDERLITER 2435 S. ALSTON AVENUE DURHAM, NC 27713 4. The name of the registered agent is: MICHAEL A. HINDERLITER 5. The street address, mailing address, and county of the registered office of the limited liability company is as follows: Street address: 2435 S. ALSTON AVENUE DURHAM, NC 27713 County: DURHAM 6. The street address of the limited liability company and the principal office of the limited liability company is: 2435 S. ALSTON AVENUE DURHAM, NC 27713 DURHAM COUNTY, NC The mailing address of the limited liability company and the principal office of the limited liability company is: 2435 S. ALSTON AVENUE DURHAM, NC 27713 DURHAM COUNTY, NC 7. This Limited Liability Company shall be a MANAGER MANAGED LLC: except as provided by N.C.G.S. Section 57D-3-20(a), the members of this limited liability company shall not be managers by virtue of their status as members. 8. No Manager of the company shall have personal liability arising out of an action whether by or in the right of the Company or otherwise for monetary damages for breach of any duty as a Manager, provided however, that the forgoing shall not limit or eliminate the personal liability of a Manager with respect to (i) acts or omissions that such director at the time of such breach knew or believed were clearly in conflict with the best interests of the Company, or (ii) any liability under North Carolina General Statues for unlawful distributions. Furthermore, notwithstanding the forgoing provision, in the event that the North Carolina General Statutes are amended or enacted to permit further limitation or elimination of the personal liability of a Manager, or by way of inference or interpretation a director of a corporation„ the personal liability of the Company's Manager shall be limited or eliminated to the fullest extent permitted or allowable by the applicable law. This article shall not affect a provision permitted under the North Carolina General Statues in the articles of organization, operating agreement or contract or resolution of the company indemnifying or agreeing to indemnify a manager against personal liability. Any repeal or modification of this article shall not adversely affect any limitation hereunder on the personal liability of a Manager with respect to acts or omissions occurring prior to such repeal or modification. The Manager of the LLC shall be as follows: MICHAEL A. HINDERLITER 2435 S. ALSTON AVENUE DURHAM, NC 27713 11. These Articles of Organization shall be effective upon filing. Executed on this the 29th day of August, 2018. ORGANIZER: ICHAEL A. HINDERLITER { c 77 Vl i GENERAL EIECTRrc DR if 7. J, Q i r S4' �G /� � 1� �! L`1,�4-� J � 1` •, \,/f ,,. 11� ,' f /i�:.,F J1, PAGE 7944 ti tj ol 73 -78.8750' 92 93 94 J 95 96 Produced by the United States Geological Survey I JJ North American Datum of 1983 (NAD83) MK. World Geodetic System of 1984 (WG584). Projection and 1 wo-meter grid:Universat transverse Mercator, Zone 17s N 1 0.5 This map is not a legal document. Boundaries may be sou l000 BASS, NIXON & KENNEDY, INC., CONSULTING ENGINEERS 6310 CHAPEL HILL ROAD, SUITE 250, RALEIGH, NC 27607 919/851-4422 ■ FAX 919/851-8968 BNK@BNKinc.com August 31, 2020 NCDEQ — Division of Water Resources Raleigh Regional Office 3800 Barrett Drive Raleigh, NC 27609 VC peAt of ien virbnm enral Quality Aug 3 , R `gl ona1 Office Re: S. Miami Blvd Building Expansion 3921 S. Miami Boulevard, Durham, NC Fast Track Sewer System Extension Application To Whom It May Concern: The site for the proposed sanitary sewer extension is located at 3921 S. Miami Boulevard in Durham, North Carolina (PIN 0748-45-23-8701). The site is located on the east side of S Miami Boulevard, north of Chin Page Road and south of Patriot Drive and is within the City of Durham City Limits. The proposed site improvements include the construction of two new buildings, expanding the existing building and additional parking/sidewalks. The Phase 1 building (Building 2) includes approximately 50,000 SF and the Phase 2 building (Building 3) includes approximately 23,200 SF. The overall site improvements include the addition of 5 loading bays for warehouse space with 90 employees. This application is for permitting of approximately 351 LF of 8" PVC sanitary sewer and 4,875 gpd of domestic wastewater discharge. The following information is included for review and approval: • Fast track application for the proposed sewer extension (original and one copy) • Check in the amount of $480.00 for processing fee • Documentation that corporation is registered for business with the North Carolina Secretary of State • Flow Tracking/Acceptance Form (FTSE 04-16) • USGS Map showing site location • Aerial Street Level Map showing project location Please let us know if the attached will be acceptable or if you have any questions/comments concerning the submittal package. Thanks for your help. Very truly yours, Bass, Nixon & Kennedy, Inc. Davi L. Dunn, PE Principal Engineer