Loading...
HomeMy WebLinkAboutNCG551185_Compliance Evaluation Inspection_20200911EPA United States Environmental Protection Agency Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 N 52 NCG551185 20/09/11 C S31112171819 20 21 66 Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA ----------------------Reserved------------------- N67707172 73 74 75 80 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) 66 Lake Lure Highway 66 Lk Lure Hwy Bat Cave NC 28710 Entry Time/Date Permit Effective Date Exit Time/Date Permit Expiration Date 10:00AM 20/09/11 13/08/01 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Other Facility Data 11:00AM 20/09/11 18/07/31 Name, Address of Responsible Official/Title/Phone and Fax Number Curtis McCart,66 Lk Lure Hwy Bat Cave NC 28710//626-786-9333/Contacted No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Operations & Maintenance Self-Monitoring Program Effluent/Receiving Waters Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s)Agency/Office/Phone and Fax Numbers Date Daniel J Boss DWR/ARO WQ/828-296-4658/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page#1 9/14/2020 NPDES yr/mo/day 20/09/11 Inspection Type C3111218 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) On 9/11/2020, I (Daniel Boss) conducted a compliance evaluation inspection of the wastewater treatment facility at 66 Lake Lure Highway. I met with Kendall (resident) for the inspection and Kendall had Curtis McCart on speaker phone for assistance. The system was checked for proper operation one week prior by Sid Gaskin who installed the system. The UV bulb was replaced and is now working. This wastewater system consists of a septic tank, fixed film biomass pod system, recirculation tank, UV disinfection, and cascade aeration. The cascade was covered with rocks, but they were not inhibiting the effluent flow and I could still see the effluent pipe. The effluent appeared clear and did not have a detectable odor. Samples have not been taken for this system. Sampling and analysis should be done annually if the system is discharging. NCG551185 17 (Cont.) Page#2 Permit:NCG551185 Inspection Date:09/11/2020 Owner - Facility: Inspection Type: 66 Lake Lure Highway Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Septic Tank Yes No NA NE (If pumps are used) Is an audible and visual alarm operational? Is septic tank pumped on a schedule? Are pumps or syphons operating properly? Are high and low water alarms operating properly? This system has only been in operation for 3 years with only partial residency. The septic tank was checked one week ago and it did not need pumping yet. Comment: Sand Filters (Low rate)Yes No NA NE (If pumps are used) Is an audible and visible alarm Present and operational? Is the distribution box level and watertight? Is sand filter free of ponding? Is the sand filter effluent re-circulated at a valid ratio? # Is the sand filter surface free of algae or excessive vegetation? # Is the sand filter effluent re-circulated at a valid ratio? (Approximately 3 to 1) This is not a sand filter system, but rather a fixed film biomass pod system. It appeared to be operating fine. Comment: Disinfection - UV Yes No NA NE Are extra UV bulbs available on site? Are UV bulbs clean? Is UV intensity adequate? Is transmittance at or above designed level? Is there a backup system on site? Is effluent clear and free of solids? This system has only one UV bulb. If it malfunctions, there is a visual alarm light on the control box. Comment: Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? Page#3 Permit:NCG551185 Inspection Date:09/11/2020 Owner - Facility: Inspection Type: 66 Lake Lure Highway Compliance Evaluation Effluent Pipe Yes No NA NE Are the receiving water free of foam other than trace amounts and other debris? If effluent (diffuser pipes are required) are they operating properly? Comment: Effluent Sampling Yes No NA NE Is composite sampling flow proportional? Is sample collected below all treatment units? Is proper volume collected? Is the tubing clean? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type representative)? Effluent sampling and analysis are not being conducted, but should be done annually as long as the system is discharging. Comment: Page#4