Loading...
HomeMy WebLinkAboutSW3191101_Add Info_20191209ROY COOPER Governor MICHAEL S. REGAN Secretary S. DANIEL SMITH Director Steve Farmartino, PE 1927 S Tryon Street Suite 310 Charlotte, NC 28203 NORTH CAROLINA Environmental Quality December 9, 2019 Subject: Request for Additional Information Stormwater Permit No. SW3191101 Cambridge Village Multifamily Lincoln County Dear Mr. Farmartino: The Division of Energy, Mineral and Land Resources (DEMLR), received a Stormwater Management Permit Application for the subject project on November 8, 2019. A review of that information has determined that the application is not complete. The following information is needed to continue the stormwater review: 1. The provided coordinates are close to the project site but should be located on the property that the permit is being applied for (Section I, 4). Please provide coordinates that are located on the property of the subject project. 2. Since the applicant is a purchaser, please provide a copy of the pending sales agreement for the property (Section III, lc). If the property has since been conveyed, please correct this section to show the applicant as the owner. 3. Please provide the name of the signing official for the property owner organization (Section III, 2a). 4. There are no existing surface waters shown on the USGS topographic map for the project site (Section IV, 6 & Section VI, 8h). If there are existing surface waters within this project area, please delineate them and their required buffers, if not, please recalculate the total project area. 5. The surface area of the wet ponds is not considered impervious area and does not need to be accounted for or treated (Section IV, 10). If you like, you may reallocate this impervious area to the future column or remove it from the table and calculations. D EQ North Carolina Department of Environmental Quality I Division of Energy, Mineral and Land Resources 512 North Salisbury Street 1 1612 Mail Service Center I Raleigh, North Carolina 27699-1612 NORTH CAROLINA _ o.PaWnamofEnvironmental Quality /� 919.707.9200 6. Please complete a Supplement-EZ Form for each SCM. The Supplement-EZ Form can be found here: hgps://deq.nc.gov/about/divisions/energ_y-mineral-land-resources/ener�,y- mineral-land-permit-guidance/stormwater-bmp-manual (Section V & Section VI, 3). 7. The O&M Agreement Form is missing some pages (Section V & Section VI, 3). Please ensure that both "Enable Editing" and "Enable Content" are clicked on the spreadsheet. Once the information is entered into the spreadsheet, click on the "Click to update 0&M manual" link to generate the additional pages. A similar process will need to be done for the Supplement-EZ form to generate all of the pages. 8. Please provide a USGS topographic map showing the project location (Section VI, 6). 9. Please ensure that all sheets (As applicable) include a north arrow. For example, sheets C-908, C-909, and possibly others are missing north arrows (Section VI, 8e). 10. Please delineate the wetlands on the plans or provide a note stating that no wetlands exist. Provide documentation of the qualifications and identity of the individual who made this determination (Section VI, 8m). 11. Please provide official documents showing the affiliation of the person listed in Section III, 1a with North Pilot Road, LLC (Section VI, 11). 12. Please provide official documents showing that Steven Bailey is able to sign on behalf of BBC Cambridge, LLC (Section IX). 13. The person signing the Applicant's Certification (Section X), Tadd Miller, is not the same person as listed in Section III, la, Jacob Jacobson. Please revise for consistency. 14. Please QA/QC the package prior to the next submission. Some noted errors include, but are not limited to the following: a. Sheet C-908 i. The inflow invert is below the bottom of the wet pond. ii. The top of the pond is below the permeant pool elevation. iii. The project name shown in the BMP Insert Table is incorrect. 15. Wet Pond 1 a. The provided stage storage tables in the SWM report do not match the plan drawings, for example, the shelf elevations. b. The wet pond, as designed, short circuits from STM B-10 to STM B-60 Wet Pond MDC 4). c. The provided forebay is larger than 20% of the main pool volume (Wet Pond MDC 5). d. The design volume drawdown time is too slow (Wet Pond MDC 7). Check your calculations, the pond height is not 792.0' . 16. Wet Pond 2 a. The main pool average depth appears to be too shallow and is calculated incorrectly (Wet Pond MDC 2). Please refer to the Stormwater Design Manual, Part C-3 for average depth calculation equations. b. The provided forebay is smaller than 15% of the main pool volume (Wet Pond MDC 5). c. The design volume drawdown time is too slow (Wet Pond MDC 7). Check your calculations, the pond height is not 783.0'. d. Based on the information shown on sheet C-301, the main pool of the wet pond is not located on the property. Please provide an agreement between the applicant and the adjoining property owner (Cambridge -Denver, LLC) allowing for the construction of an off -site SCM. e. The proposed main pool area of this facility appears to be covered under an existing stormwater permit, SW3160904. Please clarify the extents of this existing permit and if constructing the proposed wet pond in this location will cause a reduction in the water quality treatment provided by the existing facility. 17. Provide pdfs of all revisions, 2 hardcopies of revised plan sheets, and 1 hardcopy of other documents. Pdfs must be uploaded using the form at: hgps://edocs.deq.nc.gov/Forms/SW Project Submittal While it is not required, it is recommended that Wet Pond 2 be equipped with an emergency spillway. Even though the wet pond is sized to handle the 100-year storm, an emergency spillway can prevent structural failure of the embankment if the outlet structure became clogged or obstructed during a large storm event. Please note that this request for additional information is in response to a preliminary review. The requested information should be received by this Office prior to January 8, 2020, or the application will be returned as incomplete. The return of a project will necessitate resubmittal of all required items, including the application fee. Please reference the State assigned project number SW3191101 on all correspondence. If you need additional time to submit the information, please submit your request for a time extension to the Division at the contact below. The request must indicate the date by which you expect to submit the required information. The Division is allowed 90 days from the receipt of a completed application to issue the permit. The construction of any impervious surfaces, other than a construction entrance under an approved Sedimentation Erosion Control Plan, is a violation of NCGS 143-215.1 and is subject to enforcement action pursuant to NCGS 143-215.6A. If you have any questions concerning this matter please feel free to contact me at Jim.Farkas@ncdenr.gov or (919) 707-3646. Sincerely, )elfM4� Jim Farkas Environmental Engineer Stormwater Program cc: Mooresville Regional Office