Loading...
HomeMy WebLinkAboutNCG550704_Compliance Evaluation Inspection_20200903EPA United States Environmental Protection Agency Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 N 52 NCG550704 20/09/03 C S31112171819 20 21 66 Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA ----------------------Reserved------------------- N67707172 73 74 75 80 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) 175 Remington Trail 175 Remington Trl Horse Shoe NC 28742 Entry Time/Date Permit Effective Date Exit Time/Date Permit Expiration Date 10:00AM 20/09/03 19/11/07 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Other Facility Data 10:40AM 20/09/03 20/10/31 Name, Address of Responsible Official/Title/Phone and Fax Number Wilma D Trahan,175 Remington Trl Mills River NC 28759///Contacted No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Operations & Maintenance Self-Monitoring Program Effluent/Receiving Waters Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s)Agency/Office/Phone and Fax Numbers Date Lauren E Armeni DWR/ARO WQ/828-296-4500/ Daniel J Boss DWR/ARO WQ/828-296-4658/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page#1 DocuSign Envelope ID: 2EB49AC5-06F3-4E33-AC3F-197063F49A02 9/18/2020 9/18/2020 NPDES yr/mo/day 20/09/03 Inspection Type C3111218 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) On 9/2/2020, I (Daniel Boss) and Lauren Armeni conducted a compliance evaluation inspection of the wastewater treatment facility at 175 Remington Trail. We met with the owner, Wilma Trahan. Ms. Trahan was able to provide us with the receipt of the latest septic tank pumping, which was in May of 2020. There were no chlorine tablets in the chlorinator. The cover to the chlorine contact chamber was made of netting and the netting was broken. This is a safety hazard and should be addressed. The cover should be made of a sturdier, waterproof material. The system was discharging at the time of the inspection. NCG550704 17 (Cont.) Page#2 DocuSign Envelope ID: 2EB49AC5-06F3-4E33-AC3F-197063F49A02 Permit:NCG550704 Inspection Date:09/03/2020 Owner - Facility: Inspection Type: 175 Remington Trail Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Septic Tank Yes No NA NE (If pumps are used) Is an audible and visual alarm operational? Is septic tank pumped on a schedule? Are pumps or syphons operating properly? Are high and low water alarms operating properly? The septic tank was pumped in May of 2020.Comment: Sand Filters (Low rate)Yes No NA NE (If pumps are used) Is an audible and visible alarm Present and operational? Is the distribution box level and watertight? Is sand filter free of ponding? Is the sand filter effluent re-circulated at a valid ratio? # Is the sand filter surface free of algae or excessive vegetation? # Is the sand filter effluent re-circulated at a valid ratio? (Approximately 3 to 1) Comment: Pump Station - Effluent Yes No NA NE Is the pump wet well free of bypass lines or structures? Are all pumps present? Are all pumps operable? Are float controls operable? Is SCADA telemetry available and operational? Is audible and visual alarm available and operational? Comment: Disinfection-Tablet Yes No NA NE Are tablet chlorinators operational? Are the tablets the proper size and type? Page#3 DocuSign Envelope ID: 2EB49AC5-06F3-4E33-AC3F-197063F49A02 Permit:NCG550704 Inspection Date:09/03/2020 Owner - Facility: Inspection Type: 175 Remington Trail Compliance Evaluation Disinfection-Tablet Yes No NA NE Number of tubes in use?0 Is the level of chlorine residual acceptable? Is the contact chamber free of growth, or sludge buildup? Is there chlorine residual prior to de-chlorination? Chlorinator tubes were empty. The chlorine contact chamber only had a broken piece of netting covering it. This is a safety hazard. Comment: Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? Are the receiving water free of foam other than trace amounts and other debris? If effluent (diffuser pipes are required) are they operating properly? Effluent pipe was discharging.Comment: Effluent Sampling Yes No NA NE Is composite sampling flow proportional? Is sample collected below all treatment units? Is proper volume collected? Is the tubing clean? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type representative)? Samples are not being taken.Comment: Page#4 DocuSign Envelope ID: 2EB49AC5-06F3-4E33-AC3F-197063F49A02