Loading...
HomeMy WebLinkAboutNCG551511_Compliance Evaluation Inspection_20200916EPA United States Environmental Protection Agency Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 N 52 NCG551511 20/09/16 C S31112171819 20 21 66 Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA ----------------------Reserved------------------- N67707172 73 74 75 80 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) 3001 Butler Bridge Road 3001 Butler Bridge Rd Mills River NC 28759 Entry Time/Date Permit Effective Date Exit Time/Date Permit Expiration Date 09:00AM 20/09/16 15/08/20 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Other Facility Data 09:30AM 20/09/16 18/07/31 Name, Address of Responsible Official/Title/Phone and Fax Number Peggy R Block,4940 Jewell Rd Paducah KY 42001//270-217-2312/Contacted No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Operations & Maintenance Self-Monitoring Program Effluent/Receiving Waters Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s)Agency/Office/Phone and Fax Numbers Date Daniel J Boss DWR/ARO WQ/828-296-4658/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page#1 9/16/2020 NPDES yr/mo/day 20/09/16 Inspection Type C3111218 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) On 9/16/2020, I (Daniel Boss) conducted a compliance evaluation inspection of the wastewater treatment system at 3001 Butler Bridge Rd. I met with Elizabeth Koch who is the daughter of the system owner (Peggy Block) and resident of the home. This system has a septic tank, sand filter, recirculation tank, and UV disinfection. The control panel for the pumps doesn't appear to have audio or visual alarms. The indicator for the UV status on the control panel appears to indicate that the UV bulb needs replacement. Effluent sampling has not been performed because Ms. Koch was not able to locate a laboratory able to perform the sample analysis. NCG551511 17 (Cont.) Page#2 Permit:NCG551511 Inspection Date:09/16/2020 Owner - Facility: Inspection Type: 3001 Butler Bridge Road Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Septic Tank Yes No NA NE (If pumps are used) Is an audible and visual alarm operational? Is septic tank pumped on a schedule? Are pumps or syphons operating properly? Are high and low water alarms operating properly? The system has only been used for 3 years with 2 people in residence. The owner plans to pump the septic tank in 2 years. It is not clear if there are audio and visual alarms on the control panel. Comment: Sand Filters (Low rate)Yes No NA NE (If pumps are used) Is an audible and visible alarm Present and operational? Is the distribution box level and watertight? Is sand filter free of ponding? Is the sand filter effluent re-circulated at a valid ratio? # Is the sand filter surface free of algae or excessive vegetation? # Is the sand filter effluent re-circulated at a valid ratio? (Approximately 3 to 1) Unknown if the tanks have alarms.Comment: Disinfection - UV Yes No NA NE Are extra UV bulbs available on site? Are UV bulbs clean? Is UV intensity adequate? Is transmittance at or above designed level? Is there a backup system on site? Is effluent clear and free of solids? The UV bulb may need replacement.Comment: Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? Page#3 Permit:NCG551511 Inspection Date:09/16/2020 Owner - Facility: Inspection Type: 3001 Butler Bridge Road Compliance Evaluation Effluent Pipe Yes No NA NE Are the receiving water free of foam other than trace amounts and other debris? If effluent (diffuser pipes are required) are they operating properly? Comment: Effluent Sampling Yes No NA NE Is composite sampling flow proportional? Is sample collected below all treatment units? Is proper volume collected? Is the tubing clean? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type representative)? Effluent samples have not been taken.Comment: Page#4