Loading...
HomeMy WebLinkAboutNCG500188_CEI_20200916 September 16, 2020 W Marcus Pitts Duke Energy Progress LLC 41 Mountain Farm Ln Tuckasegee, NC 28783 SUBJECT: Compliance Inspection Report Walters Hydroelectric Plant NPDES WW Permit No. NCG500188 Haywood County Dear Permittee: The North Carolina Division of Water Resources conducted an inspection of the Walters Hydroelectric Plant on 9/14/2020. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in NPDES WW Permit No. NCG500188. The findings and comments noted during this inspection are provided in the enclosed copy of the inspection report entitled "Compliance Inspection Report". If you should have any questions, please do not hesitate to contact me at 828-296-4686 or via email at mikal.willmer@ncdenr.gov. Sincerely, Mikal Willmer, Environmental Specialist II Water Quality Regional Operations Section Asheville Regional Office Division of Water Resources, NCDEQ ATTACHMENTS: Inspection Report Ec: LF DocuSign Envelope ID: BF2E9C15-F500-44EC-9135-B9B4894C0930 EPA United States Environmental Protection Agency Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 N 52 NCG500188 20/09/14 C S31112171819 20 21 66 Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA ----------------------Reserved------------------- N67707172 73 74 75 80 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Walters Hydroelectric Plant 1251 Waterville Rd Waynesville NC 28786 Entry Time/Date Permit Effective Date Exit Time/Date Permit Expiration Date 09:30AM 20/09/14 16/01/19 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Other Facility Data 10:30AM 20/09/14 20/07/31 Name, Address of Responsible Official/Title/Phone and Fax Number W Marcus Pitts,41 Mountain Farm Ln Tuckasegee NC 28783//864-304-9703/Contacted No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Operations & Maintenance Records/Reports Self-Monitoring Program Facility Site Review Effluent/Receiving Waters Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s)Agency/Office/Phone and Fax Numbers Date Mikal Willmer DWR/Division of Water Quality/828-296-4686/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page#1 DocuSign Envelope ID: BF2E9C15-F500-44EC-9135-B9B4894C0930 9/16/2020 9/16/2020 NPDES yr/mo/day 20/09/14 Inspection Type C3111218 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Inspector Mikal Willmer, with the Asheville Regional Office, conducted a compliance evaluation inspection of Duke's Walters Powerhouse hydroelectric discharge. This inspection was conducted to determine whether the facility is being operated and maintained in compliance with General NPDES Permit NCG500000 under Certificate of Coverage NCG500188. Glenn Long, Duke Energy, was present and assisted in the inspection. All documents and data were reviewed for compliance before the inspection. A visual inspection of the sumps and turbines within facility was not requested due to Covid precautionary measures. The effluent location below the tailraces appeared to be free of sheen at the time of the inspection. The sumps are equipped with oil detection devices. The upstream and downstream locations appear to be adequate. Duke implements BMPs to prevent any release of oil and grease from the system. NCG500188 17 (Cont.) Page#2 DocuSign Envelope ID: BF2E9C15-F500-44EC-9135-B9B4894C0930 Permit:NCG500188 Inspection Date:09/14/2020 Owner - Facility: Inspection Type: Walters Hydroelectric Plant Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge Judge, and other that are applicable? This is a hydroelectric facility. Permittee samples quarterly for all parameters to maintain a consistent monitoring schedule. Comment: Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new application? Is the facility as described in the permit? # Are there any special conditions for the permit? Is access to the plant site restricted to the general public? Is the inspector granted access to all areas for inspection? Inspection occurred outside. No visible issues noted at the tailrace near the discharge location. Condition in general permit that further defines temperature requirement and monitoring locations for hydro facilities. Comment: Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? Is all required information readily available, complete and current? Are all records maintained for 3 years (lab. reg. required 5 years)? Are analytical results consistent with data reported on DMRs? Is the chain-of-custody complete? Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCs Are DMRs complete: do they include all permit parameters? Has the facility submitted its annual compliance report to users and DWQ? (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift? Is the ORC visitation log available and current? Is the ORC certified at grade equal to or higher than the facility classification? Page#3 DocuSign Envelope ID: BF2E9C15-F500-44EC-9135-B9B4894C0930 Permit:NCG500188 Inspection Date:09/14/2020 Owner - Facility: Inspection Type: Walters Hydroelectric Plant Compliance Evaluation Record Keeping Yes No NA NE Is the backup operator certified at one grade less or greater than the facility classification? Is a copy of the current NPDES permit available on site? Facility has copy of previous year's Annual Report on file for review? General NCG500000 Permit. No DMR submittal required. Quarterly data was reviewed for the facility before the inspection. General permit was onsite during the inspection. Comment: Upstream / Downstream Sampling Yes No NA NE Is the facility sampling performed as required by the permit (frequency, sampling type, and sampling location)? Upstream sample is taken from the penstock before entering the facility. Downstream location is taken at the Tobes Creek bridge. Comment: Effluent Sampling Yes No NA NE Is composite sampling flow proportional? Is sample collected below all treatment units? Is proper volume collected? Is the tubing clean? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type representative)? Facility collects all semi-annual samples quarterly.Comment: Page#4 DocuSign Envelope ID: BF2E9C15-F500-44EC-9135-B9B4894C0930 Certificate Of Completion Envelope Id: BF2E9C15F50044EC9135B9B4894C0930 Status: Completed Subject: Please DocuSign: NCG500188_CEI.ltr.docx, NCG500188_CEI.insp.pdf Source Envelope: Document Pages: 5 Signatures: 3 Envelope Originator: Certificate Pages: 2 Initials: 0 Mikal Willmer AutoNav: Enabled EnvelopeId Stamping: Enabled Time Zone: (UTC-05:00) Eastern Time (US & Canada) 217 W. Jones Street Raleigh, NC 27699 Mikal.willmer@ncdenr.gov IP Address: 149.168.204.10 Record Tracking Status: Original Sep 16, 2020 | 13:38 Holder: Mikal Willmer Mikal.willmer@ncdenr.gov Location: DocuSign Signer Events Signature Timestamp Mikal Willmer mikal.willmer@ncdenr.gov Environmental Specialist North Carolina Department of Environmental Quality Security Level: Email, Account Authentication (None) Signature Adoption: Pre-selected Style Using IP Address: 149.168.204.10 Sent: Sep 16, 2020 | 13:40 Viewed: Sep 16, 2020 | 13:40 Signed: Sep 16, 2020 | 13:41 Electronic Record and Signature Disclosure: Not Offered via DocuSign Daniel Boss daniel.boss@ncdenr.gov Environmental Specialist North Carolina Department of Environmental Quality Security Level: Email, Account Authentication (None) Signature Adoption: Pre-selected Style Using IP Address: 149.168.204.10 Sent: Sep 16, 2020 | 13:41 Viewed: Sep 16, 2020 | 13:42 Signed: Sep 16, 2020 | 13:44 Electronic Record and Signature Disclosure: Not Offered via DocuSign In Person Signer Events Signature Timestamp Editor Delivery Events Status Timestamp Agent Delivery Events Status Timestamp Intermediary Delivery Events Status Timestamp Certified Delivery Events Status Timestamp Carbon Copy Events Status Timestamp Witness Events Signature Timestamp Notary Events Signature Timestamp Envelope Summary Events Status Timestamps Envelope Sent Hashed/Encrypted Sep 16, 2020 | 13:41 Certified Delivered Security Checked Sep 16, 2020 | 13:42 Signing Complete Security Checked Sep 16, 2020 | 13:44 Envelope Summary Events Status Timestamps Completed Security Checked Sep 16, 2020 | 13:44 Payment Events Status Timestamps