Loading...
HomeMy WebLinkAboutWQ0041948_Application (FTSE)_20200908200 South Tryon Street, Suite 1400 Charlotte, NC 28202 tr Charlotte p+704 376 1555 f+704 376 7851 url+ www.colejeneststone.com N 202(��,leigh NJQN0s MOOR VILLEfgEOIONAL'FFICE, SeJenest Stone ZORA - University Project The proposed ZORA - University project is located on a t12-acre site off Rocky River Road. (SR-2828) in Charlotte, NC. The site is currently single-family homes. The proposed private sanitary sewer includes development of (108) single-family residential Shaping the Environment Realizing the Possibilities units which will generate a design wastewater flow of 22,120 GPD. A proposed private 8"& 6" sanitary sewer collection system is to be constructed within the new private common open space areas and will outfall via (2) public 8" sewer and (1) public doghouse manhole, to be connected to an existing 8" public sewer located east of the project site. The proposed private sanitary sewer system to be permitted with the enclosed application will be owned and maintained by the Suncrest REALop, LP. Attached Items:frtIr%3L 1. Fast Track Application (t Land Planning 2. Application Fee of $480.00 + 3. Topographic Map Landscape Architecture 4. Street Aerial Map + 5. Flow Tracking/Acceptance Form Civil Engineering 6. Limited Partnership Document + 7. Operational Agreement (FORM DEV) Urban Design PASDSURGA4648\500 - Permits�20 - ApplicationslNCDEQIINDV SHEETS\4648 - NCDEQ Modification Cover Letter.doc Shaping the Environment Realizing the Possibilities Land Planning Landscape Architecture Y Civil Engineering + Urban Design 200 South Tryon Street, Suite 1400 Charlotte, NC 28202 p+704 376 1555 f+704 376 7851 url+ www.coleieneststone. Date: August 21, 2020 toorv. s lllr LJ. Reference: 4648 ZORA - University Attention: Water Quality Official Company: Mooresville Regional Office Water Quality Section 610 E. Center Ave. Mooresville, NC 28115 We Are Transmitting: Transmitted Via: Remarks: h161-0-1— By: 020 Charlotte Raleigh TRANSMITTAL Tel: (704) 663-1699 ® Herewith ❑ Under Separate Cover Copies Dated Description 1 N/A Cover Letter 1 08/19/2020 Original Application (FTA 04-16 & 1 Copy 1 08/17/2020 Application Fee Check # Z Z 3 "7 1 02/25/2020 Topographic Ma 1 02/25/2020 Street Aerial Ma 1 01/23/2020 Flow Trackin FTSE 10-18 1 09/12/2018 Limited Partnership Document Form LP-04 1 08/19/2020 Operational A reement FORM DEV Li mail LJ Overnight N Courier ❑ Hand Deliver y El Pick -Up ® For Approval ❑ For Your Use ❑ As Requested ❑ For Review Please find the enclosed document and fee for the ZORA - University Fast Track Sewer Extensional Application submittal. If you have any questions or need additional information, please contact our office. Thank you, KoDert ti. Hayes, tl, umubi cc: Sean P. Paone, RLA — CJS Casey Werner, PE — Suncrest Ben R. Wood, PE - CJS P:\SDSKPROJ\4648\200 - Correspondence\40 - Transmittalst202010821 - Mooresville Regional Office Sewer Extension Application and Fee.doc WR Division of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: (�,jl i ` f t `� rto be completed by DWR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: 1. Applicant's name: Suncrest REALop, LP (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Federal ❑ State/County ❑ Municipal 3. Signature authority's name: Sean Cooney per 15A NCAC 021.0106(b) Title: Managing Partner 4. Applicant's mailing address: 2701 East Camelback Road #180 Biltmore Park City: Phoenix State: AZ Zip: 85016- 5. Applicant's contact information: Phone number: (602) 698-8655 Email Address: cwernerpsuncrestreal.com II. PROJECT INFORMATION: 1. Project name: ZORA - Universi I r MOORESVILLE RECI t,4l 0FR,, F ❑ Privately -Owned Public Utility ® OthePFC I V�I)INCDt-fli- )I1 `I z 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number: WQ00 and issued date: If new construction but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Mecklenburg 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.278413' Longitude:-80.734123' 5. Parcel ID (if applicable): 10501214 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: R. Todd Fisher License Number: 25163 Firm: ColeJenest & Stone PA Mailing address: 200 S Tryon St., Site 1400 City: Charlotte State: NC Zip: 28202-6013 Phone number: (104) 971-4533 Email Address: tfisherpcoleieneststone.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Mallard Creek WWTP Permit Number: NCO030210 Owner Name: Charlotte Water V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): WQunknown Downstream (Receiving) Sewer Size: 8 inch Svstem Wide Collection System Permit Number(s) (if applicable): WQCSunknown Owner Name(s): Charlotte Water r r_ r l 0 6{ WQ ?CAS FORM: FTA 04-16 Page I of 5 VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational A eement FORM: DEV) been attached? ® Yes ❑No ❑N/A 3. If the Applicant is a Home/Property Owners' Association, has an Operational Agreement (FORM: HOA) been attached? ❑ Yes ®No ❑N/A 4. Origin of wastewater: (check all that apply): ❑ Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ® Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motels ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ® Swimming Pool /Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater: 100 % Domestic/Commercial % Commercial % Industrial (See 15A NCAC 02T .0103(2011 4.Is there a Pretreatment Program in effect? ❑ Yes ® No 6. Hasa flow reduction been approved under 15A NCAC 02T .0114(fl? ❑ Yes ®No ➢ If yes, provide a copy of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114 W Residential Daily Design Flow a.b 190 gal/Unit No. of Units 108 Flow 20,520 GPD Swimming Pool 10 gal/Person 160 1,600 GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total 22,120 GPD a See 15A NCAC 02T .0114(b)(d), (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.0114] shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 22,120 GPD (per 15A NCAC 02T .0114) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) 8 Length (feet) 107 Material PVC 8 34 DIP 6 1969 PVC 6 771 DIP ➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: - ° 3. Design flow of the pump station: millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): gallons per minute at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B): ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(f)): 1. Does the project comply with all separations found in 15A NCAC 02T .0305(f) & (g) ® Yes ❑ No ➢ 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer systems: Setback Parameter* Separation Required Storm sewers and other utilities not listed below vertical 24 inches Water mains vertical -water over sewer including in benched trenches 18 inches Water mains horizontal 10 feet Reclaimed water lines vertical - reclaimed over sewer 18 inches Reclaimed water lines horizontal - reclaimed over sewer 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class I or Class II impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water or tide elevation and wetlands see item IX.2 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade vertical 36 inches ➢ 15A NCAC 02T.0305(g) contains alternatives where separations in 021.0305(f) cannot be achieved. ➢ **Stream classifications can be identified using the Division's NC Surface Water Classifications webpage ➢ If noncompliance with 02T.0305(a or (g), see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ® Yes ❑ No ❑ N/A ➢ See the Division's draft separation requirements for situations where separation cannot be meet ➢ No variance is required if the alternative design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ® Yes ❑ No ❑ N/A ➢ This would include Trout Buffered Streams per 15A NCAC 213.0202 4. Does the project require coverage/authorization under a 404 Nationwide or ❑ Yes ® No individual permits or 401 Water Quality Certifications? ➢ Information can be obtained from the 401 & Buffer Permitting Branch 5. Does project comply with 15A NCAC 021.0105(c)(6) (additional permits/certifications)? ® Yes ❑ No Per 15A NCAC 02T.0 I 05(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes ® No ❑ N/A ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria (latest version) as applicable? 1►1��Nf If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and supporting documents. 2. Professional Engineer's Certification: I R. Todd Fisher attest that this application for (Professional Engineer's name from Application Item III.1.) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. ao9eMoast,_ North Carolina Professional Engineer's seal, signature, and date:®®�4�'` m,...g�, f •,t � a e ® a � tl oZ�1�3 e •see�ee'V G11`��e'�S�✓� ;���®�R•.....•F���bsi� ........_'.�p��Q,f..��a.n........i�.................... 3. Applicant's Certification per 15A NCAC 02T .0106(b): I Sean Cooney attest that this application for (Signature Authority's name & title from Application Item I.3.) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance wi General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, o00,000 ertifrcation in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed as well as civil penalties up to $25,000 per violation. Signature: Date: 08-19-20 FORM: FTA 04-16 Page 5 of 5 STATE OF NORTH CAROLINA COUNTY OF Permit No. w(� c ``t"o w DEVELOPER'S OPERATIONAL AGREEMENT This AGREEMENT made pursuant to G.S. 143-215.1 (dI) and entered into this 17 day of August, 2020 , by and between the North Carolina Environmental Management Commission, an agency of the State of North Carolina, hereinafter known as the COMMISSION; and Suncrest REALop, LP , a corporation/general partnership registered/licensed to do business in the State of North Carolina, hereinafter known as the DEVELOPER. WITNESSETH: 1. The DEVELOPER is the owner of the certain lands lying in Mecklenburg County, upon which it is erecting and will erect dwelling units and other improvements, said development to be known as ZORA - University (hereinafter the Development). 2. The DEVELOPER desires, to construct a wastewater collection system with pumps, wastewater treatment works, and/or disposal facilities (hereinafter Disposal System) to provide sanitary sewage disposal to serve the Development on said lands. 3. The DEVELOPER has applied to the COMMISSION for the issuance of a permit pursuant to G.S. 143- 215.1 to construct, maintain, and operate the Disposal System. 4. The DEVELOPER has created or shall create unit ownership in said dwellings units, other improvements and lands through filing of a Declaration of Unit Ownership (hereinafter Declaration), pursuant to Chapter 47C or 47F of the North Carolina General Statutes. 5. The DEVELOPER has caused to be formed or will cause to be formed at the time of filing of the Declaration, (Unit Owners' Association) (hereinafter Association), a non-profit corporation organized and existing under and by the virtue of the laws of the State of North Carolina, for the purpose, among others, of handling the property, affairs and business of the Development; of operating, maintaining, re -constructing and repairing the common elements of the lands and improvements subject to unit ownership, including the Disposal System; and of collecting dues and assessments to provide funds for such operation, maintenance, re -construction andrepair. 6. The COMMISSION desires to assure that the Disposal System of the Development is properly constructed, maintained and operated in accordance with law and permit provisions in order to protect the quality of the waters of the State and the public interest therein. NOW, THEREFORE, in consideration of the promises and the benefits to be derived by each of the parties hereto, the COMMISSION and DEVELOPER do hereby mutually agree as follows: 1. The DEVELOPER shall construct the Disposal System in accordance with the permit and plans and specifications hereafter issued and approved by the COMMISSION, and shall thereafter properly operate and maintain such systems and facilities in accordance with applicable permit provisions and law. 2. The DEVELOPER shall not transfer ownership and/or control of the Disposal System to the Association until construction has been completed in accordance with the permit and approved plans, and the staff of the Division of Water Resources has inspected and approved of the facilities. In order to change the name of the permit holder, the DEVELOPER must request that the permit be reissued to the Association. The request must include a copy of the Association Bylaws and Declaration. 3. The DEVELOPER shall not transfer, convey, assign or otherwise relinquish or release its responsibility for the operation and maintenance of its Disposal System until a permit has been reissued to the DEVELOPER's successor. FORM: DEV 03-19 Page 1 of 2 4. The DEVELOPER shall provide in the Declaration and Association Bylaws that the Disposal System and appurtenances thereto are part of the common elements and shall thereafter be properly maintained and operated in conformity with law and the provisions of the permit for construction, operation, repair, and maintenance of the system and facilities. The Declaration and Bylaws shall identify the entire wastewater treatment, collection and disposal system as a common element which will receive the highest priority for expenditures by the Association except for Federal, State, and local taxes and insurance. 5. The DEVELOPER shall provide in the Declaration and Association Bylaws that the Disposal System will be maintained out of the common expenses. In order to assure that there shall be funds readily available to repair, maintain or construct the Disposal System, beyond the routine operation and maintenance expenses, the Declaration and Association Bylaws shall provide that a fund be created out of the common expenses. Such fund shall be separate from the routine maintenance funds allocated for the facility and shall be part of the yearly budget. 6. In the event the common expense allocation and separate fund are not adequate for the construction, repair, and maintenance of the Disposal System, the Declaration and Association Bylaws shall provide for special assessments to cover such necessary costs. There shall be no limit on the amount of such assessments, and the Declaration and Bylaws shall provide that such special assessments can be made as necessary at any time. 7. If a wastewater collection system and wastewater treatment and/or disposal facility provided by any city, town, village, county, water and sewer authorities, or other unit of government shall hereinafter become available to serve the Development, the DEVELOPER shall take such action as is necessary to cause the existing and future wastewater of the Development to be accepted and discharged into said governmental system, and shall convey or transfer as much of the Disposal System and such necessary easements as the governmental unit mayrequire as condition of accepting the Development's wastewater. 8. Recognizing that it would be contrary to the public interest and to the public health, safety and welfare for the Association to enter into voluntary dissolution without having made adequate provision for the continued proper maintenance, repair and operation of its Disposal System, the DEVELOPER shall provide in the Association Bylaws that the Association shall not enter into voluntary dissolution without first having transferred its said system and facilities to some person, corporation or other entity acceptable to and approved by the COMMISSION by the issuance of apermit. 9. The agreements set forth in numbered paragraphs 1, 2, 3, 4, 5, 6, 7, and 8 above shall be conditions of any permit issued by the COMMISSION to the DEVELOPER for the construction, maintenance, repair and operation of the Disposal System. 10. A copy of this agreement shall be filed at the Register of Deeds in the County(ies) where the Declaration is filed and in the offices of the Secretary of State of North Carolina with the Articles of Incorporation of the Association. IN WITNESS WHEREOF, this agreement was executed in duplicate originals by the duly authorized representative of the parties hereto on the day and year written as indicated by each of the VAqies named below: FOR THE ENVIRONMENTAL MANAGEMENT COMMISSION Linda Culpepper Director, Division of Water Resources (Date) FORM: DEV 03-19 Name of DEVELOPER _ By: (Signature) Sean Coor Manager Print Name and Title 08-19-20 (Date) Page 2 of 2 Mate of North Carolina Department of Environmental Quality Division of Water Resources Flow Tracking for Sewer Extension Applications (FTSE 10-18) Entity Requesting Allocation: ColeJerlest & Stone Project Name for which flow is being requested: ZORA - University (Residential) More Man one FRVE niay he required.for a single project if the owner of the WWTP is not responsible, for all pump stations along the route of the proposed wastewater flow. Complete this section only if you are the owner of the wastewater treatment plant. a. wwTP Facility Name: Mallard Creek WWTP b. WWTP Facility Permit 11: NCo030210 C. d. e. f. g• h. Afl flows are in MGD WWTP facility's permitted flow 12.00 Estimated obligated flow not yet tributary to the WWTP 1293 WWTP facility's actual avg. flow 9.692 Total flow for this specific request 0.02212 Total actual and obligated flows to the facility 11.007 Percent of permitted flow used 91.7% 1I. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (13) (c) (I))=(I3+c) Design Obligated, Pump Pump Average Approx. Not Yet "Total Current Station Station Firm Daily Flow** Current Tributary Flow Plus (Name or Permit Capacity, * (Firm / pl), Avg. Daily Daily Flow, Obligated Available Number) No. MGD MGD Flow, MGD MGD Flow Capacity*** Back Creek 5.9 2.360 1.403 0.0518 1.455 0.905 *The Firm Capacity (design flow) of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average llaily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5, per Section 2.02(A)(4)(c) of the Minimunn llesign Criteria. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): Downstream Permit Number: Back Creek Church Road Unknown Page 1 of 6 l"I' 1: 10-18 111. Certification Statement; Keri Cantrell certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, - given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and 11 plus all attached planning assessment addendums for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. Gh g 4 .� § ✓ j_v ;- 1 /23/2020 Signing Of Signature Chief Engineer Title of.Signing Official Date Page 2 of 6 FTSI10-18 Z O d � S a o LO o N Ln CL N 0 r di CN Q Cl) o O N O N Lfl N N O a V) N 00 Nt Nt 0 Z u v �o a a J 0 WN W LL 7 F- z D w z Z O U) ►;JI u i:i 11—V'WVLISS:6OZOUSZlZ 3IHdVd9d01'6^b30JN-Mmi33NisubiO)N\su.,Ie�,iddV-U\,I,,,,d �005'SMVWASMd a J Q W Q O O r r W J Q U U O N O N Ln N N O N W Nt to O Z 4F U dl O L 4_ d J O J W w r. Z D w W 1 w U iz O U) O I:I Y>—, AV (S WOI OZOZ/SZ/Z'OVMW M31A AKS'6Wb30)N -M3IA 133N1S\a3O3N\SuoOe>:IddV - 02\11'wlad - OOS\gARfONOSIIS\'d North Carolina Secretary of State Search Results Page 1 of 1 - Upload a PDF Filing • Order a Document Online • Add Entity to My Email Notification List • View Filings Legal Name Suncrest Realop LP Sosld: 1749926 Status: Current -Active O Date Formed: 9/16/2014 Citizenship: Foreign State of Incorporation: DE Annual Report Due Date: Registered Agent: National Registered Agents, Inc. Reg Office Reg Mailing Mailing 160 Mine Lake Ct Ste 200 160 Mine Lake Ct Ste 200 2701 E Camelback Rd #180 Raleigh, NC 27615 Principal Office 2701 E Camelback Rd #180 Phoenix, AZ 85016 Raleigh, NC 27615 Phoenix, AZ 85016 https://www.sosne.gov/online services/search/Business Registration Results 9/8/2020 Central Files: APS _ SWP _ 9/14/2020 Permit Number WQ0041948 Program Category Non -discharge Permit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer barry.love Coastal SWRuIe Permitted Flow 22,120 Facility Facility Name ZORA- University Location Address Owner Permit Tracking Slip Status Project Type Active New Project Version Permit Classification 1.00 Individual Permit Contact Affiliation Major/Minor Region Minor Mooresville County Mecklenburg Facility Contact Affiliation Owner Name Owner Type Suncrest Realop LP Non -Government Owner Affiliation Sean Cooney 2701 E Camelback Rd Ste 180 Dates/Events Phoenix AZ 85016 Scheduled Orig Issue App Received Draft Initiated Issuance Public Notice Issue Effective Expiration 9/14/2020 9/8/2020 9/14/2020 9/14/2020 Regulated Activities Requested /Received Events Apartment complex Additional information requested Swimming pool backwash Additional information received Wastewater collection Outfall Waterbody Name Streamindex Number Current Class Subbasin