Loading...
HomeMy WebLinkAboutNC0001422_Compliance Evaluation Inspection_20200911DocuSign Envelope ID: 65A95394-4A64-4054-B6DC-2D0250ABB8B4 ROY COOPER Governor MICHAEL S. REGAN Setrerary S. DANIEL SMITH 0tree[or James Corriher Duke Energy Progress LLC 801 Sutton Steam Plant Rd Wilmington, NC 28401 01 NORTH CAROLINA Environmental Quality September 14, 2020 SUBJECT: Compliance Inspection Report Sutton Steam Electric Plant NPDES WW Permit No. NC0001422 New Hanover County Dear Permittee: The North Carolina Division of Water Resources conducted an inspection of the Sutton Steam Electric Plant on 9/11/2020. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in NPDES WW Permit No. NC0001422. The findings and comments noted during this inspection are provided in the enclosed copy of the inspection report entitled "Compliance Inspection Report". There were no significant issues or findings noted during the inspection and therefore, a response to this inspection report is not required. If you should have any questions, please do not hesitate to contact Steve West with the Water Quality Regional Operations Section in the Wilmington Regional Office at 910-796-7215 or via email at steve.west@ncdenr.gov. Sincerely, DocuSigned by: E ev�((a Sa 6"� E3ABA14AC7DC434... Morella Sanchez -King, Regional Supervisor Water Quality Regional Operations Section Wilmington Regional Office Division of Water Resources, NCDEQ ATTACHMENTS Cc: WQS Wilmington Regional Office NPDES Compliance/Enforcement Unit NorthCemLnaDepartnientofEnvironmentslQusiity 19iuisionofWater Resoames W41mingtoa Regona:0ffice Wilmington, North Caro.in923405 910-796-7215 DocuSign Envelope ID: 65A95394-4A64-4054-B6DC-2D0250ABB8B4 United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 1 2 u 3 I NC0001422 I11 121 20/09/11 I17 18I � I 19 I s I 201 6 211IIIII 111111III II III III1 I I IIIII IIIIIIIII II J Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved ------------------- 67 I 72 I ni I 71 I 74 79 I I I I I I I80 701a I 711 L L—I L -1 I I Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES Dermit Number) 08:45AM 20/09/11 20/07/01 Sutton Steam Electric Plant 801 Sutton Steam Plant Rd Exit Time/Date Permit Expiration Date Wilmington NC 284018357 11:30AM 20/09/11 22/09/30 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Joshua Gene Schieffer/ORC/910-341-4780/ Kent Tyndall//910-341-4775 /9103414790 Roland G Rivenbark/ORC/910-341-4774/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted James Corriher,801 Sutton Seam Plant Rd Wilmington NC 28401//910-341-4750/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit 0 Flow Measurement Operations & Maintenar 0 Self -Monitoring Progran Facility Site Review N Effluent/Receiving Wate Storm Water Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Bria @§ySignedby: DWR/WIRO WQ/910-796-7341/ �L_.'I'1CS9/14/2020 1 L�2. EF61AOA14A2445... Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date d by: 9/14/2020 Morelia Sanchez -King DWR/WIRO WQ/910-796-7218/F�"sm4v� 6" EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. E3ABA14AC7DC434... Page# DocuSign Envelope ID: 65A95394-4A64-4054-B6DC-2D0250ABB8B4 NPDES yr/mo/day Inspection Type (Cont.) NC0001422 I11 12I 20/09/11 117 18 i c i Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Routine compliance evaluation inspection with the assistance of Kent Tyndall, Glen Rivenbark, and Josh Schieffer. Staff answered all questions presented and provided access to all areas of the site where inspection was requested. Work in the coal ash areas continues. Excavation of both coal ash ponds and the LOLA area is complete. The "84" pond has been filled. Remaining waters in the "71" pond and the LOLA excavation remain idle as the facility evaluates the final dewatering procedure for these two areas. The excavatior landfill capping process is nearly complete. Stormwater basins for landfill stormwater outfalls 010 and 011 are in place. The on -site Evoqua treatment facility continues to treat and discharge landfill leachate, groundwaters and stormwaters at outfall 001. The treatment performance of this system appears to be excellent according to recently -submitted data. All measured parameters are well below permit limits. A review of effluent data submitted since the last site inspection (8/18) revealed no permi limit exceedances for the permitted outfalls. Page# DocuSign Envelope ID: 65A95394-4A64-4054-B6DC-2D0250ABB8B4 Permit: NC0001422 Owner -Facility: Sutton Steam Electric Plant Inspection Date: 09/11/2020 Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Sutton Lake dikes were reinforced with concrete and rip rap after Hurricane Florence. Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ ❑ application? Is the facility as described in the permit? 0 ❑ ❑ ❑ # Are there any special conditions for the permit? 0 ❑ ❑ ❑ Is access to the plant site restricted to the general public? 0 ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? 0 ❑ ❑ ❑ Comment: Permit modification effective 7/1/20 eliminates several outfalls no lonaer used in addition to various internal outfalls. Outfall 001 includes treated wastewater associated with the coal ash landfill leachate, groundwater and stormwater. Outfall 008 includes station cooling waters, internal stormwaters, and LOLA excavation waters. Facility is prepared to submit required SPPP certification per permit condition A(19)(1)(e) by 9/30/20. The 008 copper limi (effective 10/1/22) 'Water Effect Ratio" studv continues Effluent Pipe Is right of way to the outfall properly maintained? Are the receiving water free of foam other than trace amounts and other debris? If effluent (diffuser pipes are required) are they operating properly? Comment: Each outfall was visibly observed with no visible foaming or discoloration Flow Measurement - Effluent # Is flow meter used for reporting? Is flow meter calibrated annually? Is the flow meter operational? (If units are separated) Does the chart recorder match the flow meter? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ■ ❑ Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ Comment: Flows for 001 from the wastewater treatment facility are measured by an Evogua flow meter which is routinely calibrated. Flows for the 008 outfall are based on power station pumping capacity. Effluent Sampling Is composite sampling flow proportional? Yes No NA NE ❑ ❑ ■ ❑ Page# 3 DocuSign Envelope ID: 65A95394-4A64-4054-B6DC-2D0250ABB8B4 Permit: NC0001422 Owner -Facility: Sutton Steam Electric Plant Inspection Date: 09/11/2020 Inspection Type: Compliance Evaluation Effluent Sampling Yes No NA NE Is sample collected below all treatment units? 0 ❑ ❑ ❑ Is proper volume collected? ❑ ❑ ❑ Is the tubing clean? ❑ ❑ 0 ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees ❑ ❑ 0 ❑ Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type 0 ❑ ❑ ❑ representative)? Comment: All reauired effluent samples are collected by arab method at reDresentative locations for each outfall. Upstream / Downstream Sampling Yes No NA NE Is the facility sampling performed as required by the permit (frequency, sampling type, an( 0 ❑ ❑ ❑ sampling location)? Comment: Facility participates in the Lower Cape Fear River Basin Association testing program. In addition, facility also collects its own in -stream samples at the locations described in the Dermit. (This data is included in the "comments" section of submitted a-DMRs) Page# 4