Loading...
HomeMy WebLinkAboutWQ0005135_Response to NOV-2020-DV-0338_20200831 (2)54P/2, t 13 30D T--<> s S Jr� t asN ekAl 94 f/nA/ /Gee L 90 C3 /. 46 0 . s %U uu� f, N J ?: 3 v "` SAFETY DATA SHEET According to U.S. Code of Federal Regulations 29 CFR 1910.1200, Hazard Communication. SECTION 1 • Identification of the substance/mixture and of the company/undedaft 1.1. Product identifier Product name: AXFLOC AF 9740 Type of product. Mixture. 7.2. Relevant identified uses of the substance or mixture and uses advised against Identified uses: Processing aid for industrial applications. Uses advised against: None. 1.3. Details of the supplier of the safety data sheet Axchem USA Inc. Company: 6C Oak Branch Drive Greensboro, NC 27407 United States Telephone: 336-632-0500 Telefax: 336-632-1177 E-mail address: customersupport@axchemusa.com 1.4. Emergency telephone number - 24-houremergency number: Chemtrec: 1-800-424-9300 (CCN 2174), Outside U.S. 703-527-3887 SECTION 2: Hazards identification 2.1. Classification of the substance or mixture Classificafion according to paragraph {d) of29 CFR 1910.1200: -Not classified. 2.2. Label elements Labelling according to paragraph (0 of29 CFR 1910.1200: Print Date: 01/1212017 Revision date: 03/02t2017 Page: 1 / 12 SAFETY DATA SHEET Hazard symbol(s): None. Signal word.- None. Hazard statement(s): None, Precautionary statement(s): None. 2.3. Other hazards Aqueous solutions or powders that become wet render surfaces extremely slippery. For explanation of abbreviations see Section 16. SECTION 3• Co mP9sitionftnformation on ingredients 3.1. Substances Not applicable, this product is a mixture. 3.2. Mixtures Hazardous components Sulfamic acid Concentrationl-range: CAS Number: Classification according to paragraph (d) of29 CFR 1910.1200: For explanation of abbreviations see section 16 SECTION 4• First aid measures 4.1. Description of first aid measures Inhalation: Move to fresh air. Get medical attention if symptoms occur. 2.5 - 10% 5329-14-6 Sldn Irrit. 2;H315, Eye Irrit. 2A;H319 Skin contact: Wash off with soap and plenty of water. Get medical attention if irritation develops and persists. Eye contact. Rinse immediately with plenty of water, also under the eyelids. Get medical attention. AXFLOC AF 9740 Ingestion: Rinse mouth. If conscious, give the victim plenty of water to drink. Induce vomiting, but only if victim is fully conscious. Print Date: 01/1212017 Revision date: 03/0212017 Page: 2112 SAFETY DATA SHEET 4.2. Most important symptoms and effects, both acute and delayed AXFLOC AF 9740 Powder can cause localised skin irritation in folds of the skin or under tight clothing. Contact with dust can cause mechanical irritation or drying of the skin. 4.3. Indication of any immediate medical attention and special treatment needed. None. Other information: None. SECTION 5: Fire -fighting measures 5.1. Extinguishing media Suitable extinguishing media: Water. Water spray. Foam Carbon dioxide (CO2). Dry powder. Warning! Aqueous solutions or powders that become wet render surfaces extremely slippery Unsuitable extinguishing media: None. 5.2. Special hazards arising from the substance or mixture Hazardous decomposition products: Thermal decomposition may produce: hydrogen chloride gas, nitrogen oxides (NOx), carbon oxides (COx). Hydrogen cyanide (hydrocyanic acid) may be produced in the event of combustion in an oxygen deficient atmosphere. 5.3. Advice for fire-fighters Protective measures: No special protective equipment required. Wear self contained breathing apparatus for fire fighting if necessary. Other information: Aqueous solutions or powders that become wet render surfaces extremely slippery. CTION 6: Accidental release measures 6.1. Personal precautions, protective equipment and emergency procedures Personal precautions: Aqueous solutions or powders that become wet render surfaces extremely slippery. Protective equipment: Wear adequate personal protective equipment (see Section 8 Exposure Controls/Personal Protection). Emergency procedures: Keep people away from spill/leak. Prevent further leakage or spillage if safe to do so. 6.2. Environmental precautions As with all chemical products, do not flush into surface water. Print !late: 0111212017 Revision date: 03/0212017 Page: 3 / 12 SAFETY DATA SHEET AXFLOC AF 9740 6.3. Methods and material for containment and cleaning up Small spills: Do not flush with water.Clean up promptly by sweeping or vacuum. Large spills: Do not flush with water.Prevent unauthorized access. Sweep up and shovel into suitable containers for disposal.. Residues: Sweep up to prevent slip hazard. After cleaning, flush away traces with water. 6.4. Reference to other sections SECTION 7: Handling and storage; SECTION 8: Exposure controls/personal protection; SECTION 13: Disposal considerations; SECTION 7: Handling and storage 7.1. Precautions for safe handling Avoid contact with skin and eyes. Avoid dust formation. Avoid breathing dust. Wash bands before breaks and at the end of workday. 7.2. Conditions for safe storage, including any incompatibilities Deep in a dry place. Incompatible with oxidizing agents. 7.3. Specific end uses) Processing aid for industrial applications. SECTION 8: Exposure controls/personal protection B.1. Control parameters Occupational exposure limits: None known. 8.2. Exposure controls Appropriate eneineering controls Use local exhaust if dusting occurs. Natural ventilation is adequate in absence of dusts. Individual Protection measures such as personal protective equomenh = , a)-Tye/face protection: ,ifrafety glasses with side -shields. -b) Skin protection: Workelothes protecting arms, legs and body. Print Date: 01/12/2017 Revision date: 0310212017 Page: 4l 12 SAFETY DATA SHEET AXFLOC AF 9740 i) Hand protection: PVC or other plastic material gloves. c) Respiratory protection: No personal respiratory protective equipment normally required. Dust safety masks recommended where working powder concentration is more than 10 mg/m3. d) Additional advice: Handle in accordance with good industrial hygiene and safety practice. Environmental exposure controls Do not allow uncontrolled discharge of product into the environment. Do not flush into surface water. SECTION 9• Physical and chemical properties 9.1. Information on basic physical and chemical properties a) Appearance: b) Odour c) Odour Threshold: d) pH. e) Melting point/freezing point 0Initial boiling point and boiling range: g) Flash point: h) Evaporation rate: i) Flammability (solid, gas): 1) Upper1lower flammability or explosive limits: k) Vapourpressurs: I) Vapourdensiv m) Relative density. n) Solubility(tes): o) Partition coefficient p) Autoignition temperature: q) Decomposition temperature: r) Viscosity s):-Explosive properties: Granular solid, White. None. Not applicable. 2.5-4.5@5g/L > 100°C Not applicable. Not applicable. Not applicable. Not combustible. Not expected to create explosive atmospheres, Not applicable. Not applicable, 0.6 - 0.9 Soluble in water, <0 Not applicable. > 2000C See Technical Bulletin. Not expected to be explosive based on the chemical structure. Print Date: 0111212017 Revision date:03/02/2017 Page: 5112 SAFETY DATA SHEET t) Oxidizing properties: 9.2.Other information None. SECTION 10: Stability and reactivity 10.7. Reactivity Hazardous polymerisation does not occur. 1D.2. Chemical stability Stable. 10.3. Possibility of hazardous reactions Oxidizing agents may cause exothermic reactions. 140.4. Conditions to avoid None known. 10.5. Incompatible materials Oxidizing agents. 10.6. Hazardous decomposition products AXFLOC AF 9740 Not expected to be oxidising based on the chemical structure. Thermal decomposition may produce: hydrogen chloride gas, nitrogen .oxides (NOx), carbon oxides (COx). Hydrogen cyanide (hydrocyanic acid) may be produced in the event of combustion in an oxygen deficient atmosphere. SECTION 11: Toxicological information 11.1. Information on toxicological effects Information on the product as suoolied: Acute oral toxicity. LD50/oral/rat > 5000 mg/kg Acute dermal toxicity: LD50/dermal/rat> 5000 mg/kg Acute inhalation toxicity: The product is not expected to be toxic by inhalation. Skin corrostonfirritation: Not irritating. Serious eye damage%ye irritation: Testing conducted according to the Draize technique showed the material produces no corneal or iridial effects and only slight transitory conjuctival effects similar to those which all granular materials have on conjuctivae. Respiratory/skin sensitisation: The results of testing on guinea pigs showed this material to be non -sensitizing. Mutagenicity: Not mutagcnic. Print Date: 01112R017 Revision date: 03/02t2017 Page: 6112 SAFETY DATA SHEET AXFLOC AF 9740 Carcinogenicity: Not carcinogenic. Reproductive toxicity: Not toxic for reproduction. STOT -single exposure: No known effects. STOT-repeated exposure: No known effect. Aspiration hazard: No hazards resulting from the material as supplied Relevant information on the hazardous components: Sulfamic acid Acute oral toxicity: Acute dermal toxicity.: Acute inhalation toxicity: Skin corrosionfirritation: Serious eye damageleye irritation: Respiratory/skin sensitisation: Mutagenicity: Carcinogenicity: Reproductive toxicity: STOT - single exposure: STOT-repeated exposure: Aspiration hazard: SECTION 12• Ecological information 12.1. Toxicity LD50/oral/rat > 2000 mg(kg NOAEL/dermal/rat = 2000 mg/kg (OECD 402) The product is not expected to be toxic by inhalation. Not irritating. (OECD 404) (SNF) Moderately irritating to the eyes, (EPA OPPTS 870,2400) The product is not expected to be sensitizing. Negative in the Ames Test (OECD 471) Negative in the In vitro Mammalian Cell Gene Mutation Test (OECD 476). Not mutagenic. (OECD 472, 487) based on the absence of mutagenicity, it is unlikely that the substance is carcinogenic. Information on the product as supplied: No data available. No known effects. No known effect. No known effects. Print Date: 01112/2017 Revision date: 0310212017 Page: 7112 SAFETY DATA SHEET Acute toxicity to fish: Acute toxicity to invertebrates: Acute toxicity to algae: Chronic toxicity to fish: Chronic toxicity to invertebrates: Toxicity to microorganisms: Effects on terrestrial organisms: Sediment toxicity. AXFLOC AF 9740 LC50/Danio rerio/96 hours = 5 - 10 mg/L (OECD 203) EC50/Daphnia magna/48 hours = 20 - 50 mg/L. (OECD 202) Algal inhibition tests are not appropriate. The flocculation characteristics of the product interfere directly in the test medium preventing homogenous distribution which invalidates the test. No data available. No data available. No data available. No data available. Readily biodegradable, exposure to soil is unlikely, No data available. Readily biodegradable, exposure to sediment is unlikely. Relevant information on the hazardous components• Sul fiamic acid Acute toxicity to fish: LC50/Pimephales promelas/96 hours = 70.3 mg/L (OECD 203) Acute toxicity to invertebrates: EC50/Daphnia magna/48 hours = 71.6 mg/L. (OECD 202) Acute toxicity to algae: ]C50/Scenedesmus subspicams/72 hours = 48 mg/L (OECD 201) Chronic toxicity to fish: No data available. Chronic toxicity to invertebrates: - No data available. Toxicity to microorganisms: EC50/activated sludgO3 hours > 200 mg/L (OECD 209) Effects on terrestrial organisms: No data available. Sediment toxicity No data available. 12.2. Persistence and degradability Information on the product as supplied Degradation: Readily biodegradable. Hydrolysis: At natural pHs (>6) the polymer degrades due to hydrolysis to more than 70% in 28 days. The hydrolysis products are not harmfid to aquatic organisms. Photolysis: No data available. Print We: 01/1212017 Revision date: 0310212017 Page: 8112 SAFETY DATA SHEET Relevant information on the hazardous components: Sulfamic acid Degradation: Not relevant (inorganic). Hydrolysis: Does not hydrolyse, Photolysis: No data available, 12.3. Bioaccumulative potential Information on the product as supplied: The product is not expected to bioaccumulate. Partition co -efficient (Log Pow): < 0 Bioconcentration factor (BCF): No data available. Relevant information on the hazardous components: Sul famic acid Partition co -efficient (Log Pow): -4,34 @ 20°C Bioconcentration factor (BCF): No data available. 12.4. Mobility in soil Information on the product as supplied.' No data available. Relevant information on the hazardous components: Sulfamic acid Koo. No data available. 12.5. Other adverse effects None known. SECTION 13: Disposal considerations 13.1. Waste treatment methods i3:40141193;&U.": Print Date: 01/1212017 Revision date:03/0212017 Page: 9112 SAFETY DATA SHEET AXFLOC AF 9740 Waste from residues/unused products: Dispose in accordance with local and national regulations. Can be landfilled or incinerated, when in compliance with local regulations. Contaminated oackapinp: Rinse empty containers with water and use the rinse -water to prepare the working solution. If recycling is not practicable, dispose of in compliance with local regulations. Can be landfilled or incinerated, when in compliance with local regulations. Rec clin In accordance with local and national regulations. SECTION 147 Transport information Land transport (DOT) Not classified Sea transport (IMDG) Not classified Air transport (IATA) Not classified SECTION 157 Reaulato y information 15.1. Safety, health and environmental regulationsflegislation specific for the substance or mixture Information on the product as supplied: TSCA Chemical Substances Invantorv: All components of this product are either listed on the inventory or are exempt from listing. US SARA forting Requirements: SARA (Section 3111312) hazard class: Not concerned. SARA Title 111 Sections: Section 302 (TPQ) - Reportable Quantity: Not concerned Section 304 - Reportable Quantity. Not concerned. Print Date: 01/1212017 Revision date: 0310212017 Page: 10112 SAFETY DATA SHEET Section 313 (De minimis concentration): Not concerned. Clean Water Act Section 311 Hazardous Substances (40 CFR 117.3) - Reportable Quantity: Not concerned. Clean Air Act Section 112(r) Accidental release prevention requirements (40 CFR 68) - Reportable Quantity: Not concerned- CERCLA Hazardous Substances List (40 CFR 302.4) - Reportable Quantity: Not concerned. RGRA status: Not RCRA hazardous. AXFLOC AF 9740 California Proposition 651nformation: WARNING? This product contains a chemical known to the State of California to cause cancer and birth defects or other reproductive harm, Acrylamide NFPA and HMIS Ratinas: NFPA: Health: Flammability: Instability: 1 HMIS. Health: 0 Flammability: 8 Print Date: 01102017 Revision date: 03107J2017 Page: 11112 SAFETY DATA SHEET Physical Hazard. u PPE Code: B This data sheet contains changes from the previous version in section(s): AXFLOC AF 9740 SECTION 5. Fire -fighting measures, SECTION 15. Regulatory information, SECTION 16. Other Information. Kev or leaend to abbreviations and acronvms used in the safety data sheet Abbreviations Eye Irrit. 2A = Serious eye damageleye irritation Category Code 2A Skin Irrit. 2 = Skin corrosion/irritation Category Code 2 H-Phrases H315 - Causes skin irritation H319 - Causes serious eye irritation This SDS was prepared in accordance with the following: U.S. Code of Federal Regulations 29 CFR 1910.1200 Version: 17.01.a PRCCO09 The information provided in this Safety Data Sheet is correct to the best of our knowledge, information and belief at the date of its publication. The information given is designed only as a guidance for safe handling, use, processing, storage, transportation, disposal and release and is not to be considered a warranty or quality specification. The information relates only to the specific material designated and may not be valid for such material used in combination with any other materials or in any process, unless specified in the text. Print Date: 01/1212017 Revision date: 03102/2017 Page: 12112 RPOMICROBAC Microbac Laboratories, Inc. - Fayetteville CERTIFICATE OF ANALYSIS KOF0140 Project Description Effluent sample - Mthly For: Mr. Chris Fowler Von Drehle Corporation 126 First Street Cordova, NC 28330 Administration Brittany Smith Tuesday, June 16, 2020 Please find enclosed the analytical results for the samples you submitted to Microbac Laboratories. Review and compilation of your report was completed by Microbac Laboratories, Inc. - Fayetteville. If you have any questions, comments, or require further assistance regarding this report, please contact your service representative listed above. I certify that all test results meet all of the requirements of the accrediting authority listed within this report. Analytical results are reported on a'as received' basis unless specified otherwise. Analytical results for solids with units ending in (dry) are reported on a dry weight basis. A statement of uncertainty for each analysis is available upon request. This laboratory report shall not be reproduced, except in full, without the written approval of Microbac Laboratories. The reported results are related only to the samples analyzed as received. Microbac Laboratories, Inc. 2592 Hope Mills Rd I Fayetteville, NC 283061910.864.1920 p i www.microbac.com Page 1 of 7 VMICROBAC° Microbac Laboratories, Inc. - Fayetteville CERTIFICATE OF ANALYSIS KOF0140 Von Drehle Corporation Project Name: Effluent sample - Mthly Mr. Chris Fowler Project / PO Number: N/A 126 First Street Received: 06/09/2020 Cordova, NC 28330 Reported: 06/16/2020 Sample Summary Report Sample Name Laboratory ID Client Matrix Effluent, composite KOF0140-01 Aqueous Effluent, grab KOF0140-02 Aqueous Sample Type Sample Begin Sample Taken Lab Received Composite 06/08/20 12:37 06/09/20 12:37 06/09/20 15:01 Grab 06/09/20 12:40 06/09/20 15:01 Page 2 of 7 *MICROBAC@ Microbac Laboratories, Inc. - Fayetteville CERTIFICATE OF ANALYSIS KOF0140 Analytical Testing Parameters Client Sample ID: Effluent, composite Sample Matrix: Aqueous Collected By: Wright Lab Sample ID: KOF0140-01 Collection Date: 06/09/2020 12:37 *** DEFAULT GENERAL METHOD *"" Result RL Units Dilution Note Prepared Analyzed Analyst SM 2540 D-2011 Total Suspended Solids 73.0 25.0 mg/L 10 06/10/20 1543 TBM SM 5210 B-2011 BOD 2670 2.00 mg/L 1 G5 06/10/20 1137 06/15/20 1529 MT Inorganics Total Result RL Units Dilution Note Prepared Analyzed Analyst SM 5220 D-2011 COD, Total 7120 10.0 mg/L 1 06/12/20 1125 MT Client Sample ID: Effluent, grab Sample Matrix: Aqueous Collected By: Wright Lab Sample ID: KOF0140-02 Collection Date: 06/09/2020 12:40 Field Parameters Result RL Units Dilution Note Prepared Analyzed Analyst SM 2550 B-2010 Temperature, Field 36 0.1 °C 1 06/09/20 1240 MJW SM 4500-H+ B-2011 pH, Field Test 7.4 1.0 S.U. 1 06/09/20 1240 MJW Inorganics Total Result RL Units Dilution Note Prepared Analyzed Analyst SM 4500-H+ B-2011 pH at 25'C 7.2 1.0 S.U. 1 H 06/11/20 1410 TBM Microbac Laboratories, Inc. 2592 Hope Mills Rd I Fayetteville, NC 28306 1910.864.1920 p I www.microbac.com page 3 of 7 +7 ' Microbac Laboratories, Inc. - Fayetteville CERTIFICATE OF ANALYSIS KOF0140 Batch Quality Control Summary: Microbac Laboratories, Inc. - Fayetteville Spike Source %REC RPD *** DEFAULT GENERAL Result RL Units Level Result %REC Limits RPD Limit Notes METHOD *** Batch KFOD907 - Wet Chem Aqueous - SM 2540 D-2011 Blank (KF00907-BLK1) Prepared &Analyzed: 06/10/2020 Total Suspended Solids <2.50 2.50 mg/L Blank (KF00907-BLK2) Prepared & Analyzed: 06110/2020 Total Suspended Solids <2.50 2.50 mg/L Blank (KF00907-BLK3) Prepared &Analyzed: 06/10/2020 Total Suspended Solids <2.50 2.50 mg/L Blank (KF06907-BLK4) Prepared &Analyzed: 06/10/2020 Total Suspended Solids <2.50 2.50 mg/L LCS (KF00907-BSI) Prepared & Analyzed : 06/10/2020 Total Suspended Solids 27.5 2.50 mg/L 28.1 98 94.5-105.4 Duplicate (KF00907-DUP1) Source: KOF0027.01 Prepared & Analyzed: 06/10/2020 Total Suspended Solids 13800 833 mg/L 14000 1 10 Duplicate (KF00907-DUP2) Source: KOF0085-01 Prepared &Analyzed: 06/10/2020 Total Suspended Solids 112 33.3 mg/L 92.0 20 10 Duplicate (KF00907-DUP3) Source: KOF0086.01 Prepared &Analyzed: 06/10/2020 Total Suspended Solids 118 25.0 mg/L 121 3 10 Duplicate (KF00907-DUP4) Source: KOF0137-01 Prepared &Analyzed: 06110/2020 Total Suspended Solids 48.0 25.0 mg/L 27.0 56 10 Batch KFO1219 - Wet Chem Aqueous - SM 5210 B-2011 Blank (KFO1219-BLK1) Prepared: 06/10/2020 Analyzed: 06/15/2020 BOD LCS (KF01219-BSI) <2.00 2.00 mg/L Prepared: 06/10/2020 Analyzed: 06/15/2020 BOD Duplicate(KFO1219-DUPI) 164 mg/L Source: KOF0141-01 Prepared: 198 06/10/2020 Analyzed: 83 .59596-115.4 06/15/2020 BOD 443 2.00 mg/L 480 8 10 Spike Source %REC RPD Inorganics Total Result RL Units Level Result %REC Limits RPD Limit Notes Batch KFO1105 -Wet Chem Aqueous -SM 4500-H+ B-2011 Duplicate (KFO1105-DUP1) Source: KOF0131-02 Prepared &Analyzed: 06/11/2020 pH at 25 °C 6.2 1.0 S.U. 6.2 0 10 H Batch KF01216 -Wet Chem Aqueous - SM 5220 D-2011 Blank (KFO1216-BLK1) Prepared & Analyzed: 06/12/2020 COD, Total <10.0 10.0 mg/L Blank (KFO1216-BLK2) Prepared & Analyzed: 06/12/2020 COD, Total <10.0 10.0 mg/L Microbac Laboratories, Inc. 2592 Hope Mills Rd I Fayetteville, NC 28306 1910.864.1920 p I www.microbac.com Page 4 of 7 OMICROBACO Microbac Laboratories, Inc. - Fayetteville CERTIFICATE OF ANALYSIS KOF0140 Spike Source %REC RPD Inorganics Total Result RL Units Level Result %REC Limits RPD Limit Notes Batch KFO1216 - Wet Chem Aqueous - SM 5220 D-2011 Blank (KFO1216-BLK3) Prepared & Analyzed: 06/12/2020 COD, Total <10.0 10.0 mg/L LCS (KFO1216-BS1) Prepared & Analyzed: 06/12/2020 COD, Total 505 10.0 mg/L 500 101 90-110 Duplicate (KFO1216-DUP1) Source: KOF0214-01 Prepared &Analyzed: 06/12/2020 COD, Total 39.0 10.0 mg/L 39.0 0 20 Duplicate (KFO1216-DUP2) Source: KOF0216.01 Prepared & Analyzed: 06/12/2020 COD, Total 37.0 10.0 mg/L 41.0 10 20 Matrix Spike (KF01216-MSt) Source: KOF0214-01 Prepared & Analyzed: 06/12/2020 COD, Total 68.1 10.0 mg/L 25.0 39.0 116 80-120 Matrix Spike(KF01216-MS2) Source: KOF0216.01 Prepared&Analyzed: 06/12/2020 COD, Total 76.1 10.0 mg/L 25.0 41.0 116 80-120 Definitions °C: Degrees Celsius G5: The glucose/glutamic acid standard exceeded the range of 198 t 30.5 mg/L. H: Analyte was prepared and/or analyzed outside of the analytical method holding time MDL: Minimum Detection Limit mg/L: Milligrams per Liter RL: Reporting Limit RPD: Relative Percent Difference S.U.: Standard Units Cooler Receipt Log Cooler ID: Default Cooler Temp: 12.3°C Cooler Inspection Checklist Ice Present or not required? Yes Shipping containers sealed or not required? Yes Custody seals intact or not required? Yes Chain of Custody (COC) Present? Yes CDC includes customer information? Yes Relinquished and received signature on COC? Yes Sample collector identified on COC? Yes Sample type identified on COC? Yes Correct type of Containers Received Yes Correct number of containers listed on COC? Yes Containers Intact? Yes COC includes requested analyses? Yes Enough sample volume for indicated tests received? Yes Sample labels match COC (Name, Date & Time?) Yes Samples arrived within hold time? Yes Correct preservatives on COC or not required? Yes Chemical preservations checked or not required? Yes Preservation checks meet method requirements? Yes VOA vials have zero headspace, or not recd.? Yes Project Requested Certification(s) Microbac Laboratories, Inc. - Fayetteville 11 North Carolina DENR NPDES Microbac Laboratories, Inc. 2592 Hope Mills Rd i Fayetteville, NC 28306 1910.864.1920 p I www.microbac.com Page 5 of 7 0MICROBAC° Microbac Laboratories, Inc. - Fayetteville CERTIFICATE OF ANALYSIS KOF0140 Report Comments Samples were received in proper condition and the reported results conform to applicable accreditation standard unless otherwise noted. The data and information on this, and other accompanying documents, represents only the sampleis) analyzed. This report is incomplete unless all pages indicated in the footnote are present and an authorized signature is included. The services were provided under and subject to Microbac's standard terms and conditions which can be located and reviewed at<httos.11w .mlcrobac.com/standard-terms-contlitions>. Reviewed and Approved By: Brittany Smith Administration Reported: 06/16/2020 20:08 Microbac Laboratories, Inc. 2592 Hope Mills Rd i Fayetteville, NC 28306 1910.864.1920 p I www.microbac.com Page 6 of 7 # Fayetteville Division 2592 Hope Mills Road — Fayetteville, NC 28306 (910) 864-1920 / 8( *KOF0140* * CHAIN OF CUSTODY RECORD I�N����I�Illu WU �Id �u lull F PROJECT l LOCATION: Cordova - Mthly #OF B O T T L E S TYPE OF ANALYSIS PRESERVATION CODE O in fj)DATE N o O a (D = a u 3 CODE: A = <4°C ONLY B m HNO3 (ph<2) + <4°C C = H2SO4 (ph<2) + -WC D = NaOH + <4°C E = ZN Acetate + cq°C F=Sodium Thio. T PERSON: hds Fowler 10-9131 IETHOO OF SHIPMENT: Microbac TIME COMP GRAB PH D.O. TEMP °C RES. CHLOR N 6/s,n IL 3 7 x z A tZj 1Z:J'J x 1 C GZ 0 x 1 A Time Wetl SI nature .` Y 2 ate Tim ILL Time Received by:(Signature) Date Time 4 Time Received by. (Signature) Date Tlme 6 Time Received by: (Signature) Date T(me 8 Comments or Special Hazards: Ice, Field pH: -' 4(2 Field Temp: 351, Page 7 of 7 /$v0 NUCO'Nater An Ec.tab Company SAFETY DATA SHEET NALCLEARTM'8173PULV '"�l^^ 6 6 `/ c; P o Section: 1. PRODUCT AND COMPANY IDENTIFICATION Product name NALCLEARTM 8173 PULV /6 /#5 Other means of identification Recommended use Restrictions on use Not applicable. FLOCCULANT Refer to available product literature or ask your local Sales Representative for restrictions on use and dose limits. Company Nalco Company 1601 W. Diehl Road Naperville, Illinois 60563-1198 USA TEL: (630)305-1000 Emergency telephone (800) 424-9300 (24 Hours) CHEMTREC number Issuing date : 05/11/2018 Section: 2. HAZARDS IDENTIFICATION s GHS Classification Not a hazardous substance or mixture. GHS Label element Hazard Statements If swallowed a jelly mass may form which in digestion may cause blockage. Precautionary Statements Prevention: ; Wash hands thoroughly after handling. Water in contact with the product will cause slippery floor conditions. Response: Get medical advice/ attention if you feel unwell. Storage: Store in accordance with local regulations. Other hazards None known. Section: 3, COMPOSITION/INFORMATION ON INGREDIENTS No hazardous ingredients Section: 4. FIRST AID MEASURES In case of eye contact Rinse with plenty of water. Get medical attention if symptoms occur. In case of skin contact Wash off with soap and plenty of water. Get medical attention if symptoms occur. If swallowed Rinse mouth. Get medical attention if symptoms occur. 1.�9 SAFETY DATA SHEET NALCLEARTM 8173 PULV If inhaled . Get medical attention if symptoms occur Protection of first-aiders In event of emergency assess the danger before taking action. Do not put yourself at risk of injury. If in doubt, contact emergency responders. Use personal protective equipment as required. Notes to physician Treat symptomatically. If swallowed a jelly mass may form which in digestion may cause blockage. Most important symptoms See Section 11 for more detailed information on health effects and symptoms. and effects, both acute and delayed Section: 5. FIREFIGHTING MEASURES Suitable extinguishing media Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. Unsuitable extinguishing None known. media Specific hazards during Not flammable or combustible. firefighting Hazardous combustion Decomposition products may include the following materials: Carbon oxides products nitrogen oxides (NOx) Sulphur oxides Oxides of phosphorus Special protective equipment Use personal protective equipment. for firefighters Specific extinguishing Fire residues and contaminated fire extinguishing water must be disposed of in methods accordance with local regulations. Section: 6, ACCIDENTAL RELEASE MEASURES Personal precautions, Refer to protective measures listed in sections 7 and B. Spills of this product are protective equipment and very slippery. emergency procedures Environmental precautions No special environmental precautions required. Methods and materials for Sweep up and shovel into suitable containers for disposal. containment and cleaning up Section: 7. HANDLING AND STORAGE Advice on safe handling For personal protection see section 8. Wash hands after handling. Conditions for safe storage Keep out of reach of children. Keep container tightly closed. Store in suitable labelled containers. 2rs � SAFETY DATA SHEET NALCLEARTM 8173 PULV Suitable material The following compatibility data is suggested based on similar product data and/or industry experience: Shipping and long term storage compatibility with construction materials can vary; we therefore recommend that compatibility is tested prior to use. Unsuitable material not determined Section: 8. EXPOSURE CONTROLS/PERSONAL PROTECTION Components with workplace control parameters Contains no substances with occupational exposure limit values. Engineering measures Good general ventilation should be sufficient to control worker exposure to airborne contaminants. Personal protective equipment Eye protection Safety glasses Hand protection Wear protective gloves. Gloves should be discarded and replaced if there is any indication of degradation or chemical breakthrough. Skin protection Wear suitable protective clothing. Respiratory protection No personal respiratory protective equipment normally required. Hygiene measures : Wash hands before breaks and immediately after handling the product. Section: 9. PHYSICAL AND CHEMICAL PROPERTIES Appearance Granular Colour white Odour Slight Flash point does not flash pH 7.0 - 9.0,(0.5 %) Odour Threshold no data available Melting point/freezing point no data available Initial boiling point and boiling no data available range Evaporation rate no data available Flammability (solid, gas) no data available Upper explosion limit no data available Lower explosion limit no data available Vapour pressure no data available. Relative vapour density no data available Relative density no data available SAFETY DATA SHEET NALCLEARM 8173 PULV Experience with human exposure Eye contact No symptoms known or expected. Skin contact No symptoms known or expected. Ingestion No symptoms known or expected. Inhalation No symptoms known or expected. Toxicity Product Acute oral toxicity Acute toxicity estimate: > 5,000 mg/kg Acute inhalation toxicity no data available Acute dermal toxicity Acute toxicity estimate: > 5,000 mg/kg Skin corrosion/irritation no data available Serious eye damage/eye no data available irritation Respiratory or skin no data available sensitization Carcinogenicity no data available Reproductive effects no data available Germ cell mutagenicity no data available Teratogenicity no data available STOT - single exposure no data available STOT - repeated exposure no data available Aspiration toxicity no data available Section: 12. ECOLOGICAL INFORMATION Ecotoxicity Environmental Effects : This product has no known ecotoxicological effects Product Toxicity to fish LC50 Oncorhynchus mykiss (rainbow trout): > 100 mg/I Exposure time: 96 hrs Test substance: Product LC50 Lepomis macrochirus (Bluegill sunfish): > 100 mg/I Exposure time: 96 hrs Test substance: Product LC50 Pimephales promelas (fathead minnow): > 1.000 mg/I Exposure time: 96 hrs Test substance: Product SAFETY DATA SHEET NALCLEARTm 8173 PULV taken to an approved waste handling site for recycling or disposal. Do not re -use empty containers. Section: 14. TRANSPORT INFORMATION The shipper/consignor/sender is responsible to ensure that the packaging, labeling, and markings are in compliance with the selected mode of transport. Land transport (DOT) Proper shipping name PRODUCT IS NOT REGULATED DURING TRANSPORTATION Air transport (IATA) Proper shipping name PRODUCT IS NOT REGULATED DURING TRANSPORTATION Sea transport (IMDGIIMO) Proper shipping name PRODUCT IS NOT REGULATED DURING TRANSPORTATION Section: IS. REGULATORY INFORMATION TSCA list No substances are subject to a Significant New Use Rule. No substances are subject to TSCA 12(b) export notification requirements. EPCRA - Emergency Planning and Community Right -to -Know Act CERCLA Reportable Quantity This material does not contain any components with a CERCLA RQ. SARA 304 Extremely Hazardous Substances Reportable Quantity This material does not contain any components with a section 304 EHS RQ. SARA 3111312 Hazards No SARA Hazards SARA 302 This material does not contain any components with a section 302 EHS TPQ. SARA 313 This material does not contain any chemical components with known CAS numbers that exceed the threshold (De Minirnis) reporting levels established by SARA Title III, Section 313. California Prop 65 This product does not contain any chemicals known to State of California to cause cancer, birth defects, or any other reproductive harm. INTERNATIONAL CHEMICAL CONTROL LAWS: United States TSCA Inventory The substances in this preparation are included on or exempted from the TSCA 8(b) Inventory (40 CFR 710) Australia. Industrial Chemical (Notification and Assessment) Act All substances in this product comply with the National Industrial Chemicals Notification & Assessment Scheme (NICNAS). .719 SAFETY DATA SHEET NALCLEARTM 8173 PULV Canadian Domestic Substances List (DSL) The substance(s) in this preparation are included in or exempted from the Domestic Substance List (DSL) Japan. ENCS - Existing and New Chemical Substances Inventory All substances in this product comply with the Law Regulating the Manufacture and Importation Of Chemical Substances and are listed orfthe Existing and New Chemical Substances list (ENCS). Korea. Korean Existing Chemicals Inventory (KECI) All substances in this product comply with the Chemical Control Act (CCA) and are listed on the Existing Chemicals List (ECL) Philippines Inventory of Chemicals and Chemical Substances (PICCS) All substances in this product comply with the Republic Act 6969 (RA 6969) and are listed on the Philippines Inventory of Chemicals & Chemical Substances (PICCS). China Inventory of Existing Chemical Substances All substances in this product comply with the Provisions on the Environmental Administration of New Chemical Substances and are listed on or exempt from the Inventory of Existing Chemical Substances China (IECSC). New Zealand. Inventory of Chemicals (NZIoC), as published by ERMA New Zealand All substances in this product comply with the Hazardous Substances and New Organisms (HSNO) Act 1996,and are listed on or are exempt from the New Zealand Inventory of Chemicals. Taiwan Chemical Substance Inventory All substances in this product comply with the Taiwan Existing Chemical Substances Inventory (ECSI). Section: 16. OTHER INFORMATION ) NFPA: HMIS III: Flammability s m x Special hazard. 3 m Q Revision Date 05/1112018 Version Number 12 Prepared By Regulatory Affairs 0 = not significant, 1 =Slight, 2 = Moderate, 3 = High 4 = Extreme,' = Chronic REVISED INFORMATION: Significant changes to regulatory or health information for this revision is indicated by a bar in the left-hand margin of the SDS. The information provided in this Safety Data Sheet is correct to the best of our knowledge, information and belief at the date of its publication. The information given is designed only as a guidance for safe handling, use, 8/9 North Carolina Division of Water Resources Laboratory (Water Sciences Section) Water Sample Collection & Submittal Form GDLaboratory Visit ID: Iaptional) _ Tag m YD, Lob Use Only: _________________ ____________________ sample Number.• Location Description: 1 �b�y { �"71� jf' '5/ �/p / II YKG (,r 3 XXVV'�aV Location Code: oats Received. M/Dr Time Received: (24 hrjormat) County: I C vr)3 0A/%� Collector: Priority. ____ _____ Ambient Routine Compliance COC Emergency CIA Water ___ Maoix: _________ Surface Ground Waste Blank Solution __ Location Type: __________ ___ River/Stream Estuary Stormwater Monitoring Well Effluent Field Blank Filter Blank _____________ lake Canal Water Supply Influent Trip Blank lab DI Water Other: OWR Fe9ion: (bored on manly) A _ r-vicCC- DWRo$ office!_ (nropencynameJ �" �% Received By: River Basin: +}���a f'.�-'� /'jV r (rn/d/Y): Time(24 hrJ: (begin/er d) [' l / /2 '� / /��'+ Delivery Method: State Courier Notes: - t,_ /3 j ✓ �! J "� ,�` Hand Delivered Other: Chlorinated De -chlorinated in Field Sampling Method: Grab Other Composite Filtered in Dissolved analysis: Enter"DIS" in check- Field bores for parameters Sample Depth: �..r G /d1r1� / /� / . •+ l C Temperature on Bi zj o: Collector's tommeats: Field Parameters (optional): Preservative : Y Water Temp('C): --.--- PH(s.u.): —.-.... Dissolved Oxygen (PPm): Conductivity IPmhos/cm): Salinity IPPt): i, LAB COMMENTS: Microbiology Parameters: Preservative Wet Chemistry Parameters: Preservative Metals Parameters: Preservative Metals Parameters Can't: Preservative Alkalinity, as CaCO3, to pH 4.5/8.3 A - Bromide None ^Alumimum (AI) E Thallium (TI) E SOD: Biochemical Oxygen Demand, 5-day A Chloride None Antimony (Sb) E Tin (Sn) E cBOD: Carbonaceous BOD, 5-day A Fluoride None Arsenic (As) E Titanium (Ti) E Coliform: Fecal MF B-C-L-N Sulfate A arium(Be) E V nadium(V) E Coliform: Total MF B-C-L-N Chlorophyll erylllurn(Be) E Zinc(Zn) E Specific Conductance, at 25°C A Color: ADMI A cadmium(Cd) E yarcuri, 1531, low-level TOC-Total Organic Carbon A-E-F-G Color: Platinum Cobalt A Falcium(Ca) E Boron(B) E Turbidity A COD: Chemical Oxygen Demand A-D Chromium (Cr), Total E Hardness, Total as CaCO3-by titration D-E Other Parameters: Cyanide, Total A-H-P Cobalt (Co) E Organics Parameters: PH None Formaldehyde Copper(Cu) E Acid Herbicides A-C H exaval.nt Chromium(Cr6t) A-O ran(Fe) E Organochlorine Pesticides A-C-K Nutrients Parameters: MBAS(surfactenis) A Lead (Ph) E Organonitrogen Pesticides A-C-K Ammonia as N(NH3-N) A-D-Z Oil and Grease, HEM, Total Recoverable A-D-F'[hium (U) E Organophosphorus Pesticides A-C-K y1trate-Nitrite as N(NO3+NO2-N) A-D-Z Phenols, Total Recoverable A-D agnesium(Mg) E PCBs (polychlorinated biphenyls) A-K tal Kjeldahl Nitrogen as N(TKN) A-D-Z Resi due: Total(Totalsonds) A Manganese (Mn) E Semi -Volatile Orgamics(BNAs) A-C-K Total Phosphorus as P(TP) A-D-Z Residue: Volatile/Fixed, Total A Mercury(Hut E TPH Diesel Range A-K Nitrite as N(NO2-N) A sidue: Settleable A Molybdenum(Mo) E Volatile Organics (VOA) A-C-F-S Nitrate as N (NO3-N calculated) A - Residue: Suspended (Suspended Solids) A Nicial (Ni) - E 1,4-Diozane C Orthophosphate as P(PO4) A-Z Residue; Volatile/Fixed, Suspended A Potassium(K) E TPH Gasoline Range A-C-F-S Cyanotoxins: TDS - Total Dissolved Solids A Selenium (Se) E Biological: Microcystin Silica A Silver(Ag) E Phytoplankton/Algae A-R Sulfide A-J _JASodiuni E Tannin&Ugmn I I Strontium (Sr) E �._._.._.: noH) lal rnnl <s-c IBI cool <10"C. IC10.008%Na,5,0, [when chlorine is present], (D) H,,SO, to pH <2, (E) HNO, to pH <2, (F) HCI to PH <2, (G) HSPO, to PH <2, (H) 6N NaDH to PH>30<11, (I) PH=9.3-9.7, (L) zinc acetate & NaOH to PH to >9, (K) PH 6-9 ascorbic acid [when chlorine is present], (L) EDTA, (M) NaHSO• to pH <2, (N) 15% EDTA, (0) ammonium sulfate buffer pH= 9.3-9.7, (P) ascorbic acid (when chlorine is present], (R) Lugols, (S) NaH50a to pH <2, (Y) analyzed within 15 minutes of sample collection, (Z) filtered in field within 15 minutes Required: 2) Collector Initials and Date, 2) Circling of Utilized Preservative next to each Parameter Revision: 8/1/2018