Loading...
HomeMy WebLinkAboutNCG130067_Inspection_20200812Compliance Inspection Report Permit: NCG130067 Effective: 06/01/18 Expiration: 05/31/23 Owner : Blue Ridge Plastics SOC: Effective: Expiration: Facility: Blue Ridge Plastics County: Rockingham 11511 Hwy 770 E Region: Winston-Salem Eden NC 27289 Contact Person: Darrell Pyrtle Title: Phone: 336-627-7861 Directions to Facility: From the intersection of hwy 87/14 (van buren rd) and hwy 770 (e meadow rd) in eden travel east on hwy 770 approx 4.1 mi the facility is on the left System Classifications: Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Date: 08/12/2020 Entry Time 10:25AM Exit Time: 11:20AM Primary Inspector: Zac Lentz Phone: 336-776-9661 Secondary Inspector(s): Reason for Inspection: Complaint Inspection Type: Compliance Evaluation Permit Inspection Type: Wholesale Trade of Non-metal Waste and Scrap Stormwater Discharge COC Facility Status: ❑ Compliant Not Compliant Question Areas: Storm Water (See attachment summary) Page 1 of 3 Permit: NCG130067 Owner - Facility: Blue Ridge Plastics Inspection Date: 08/12/2020 Inspection Type: Compliance Evaluation Reason for Visit: Complaint Inspection Summary: On August 12, 2020, the facility was inspected for compliance with the NCG130000 General Permit following a complaint of foul smelling water adjacent to a berm. The inspection revealed that the SWPPP (received via email on August 19, 2020) had not been updated since February 2014, and no records had been kept since then. Representatives of the facility pointed out that the individual previously responsible for stormwater compliance is no longer with the company and shared a list of deficiencies and a timeline to correct them. During the inspection, all outfalls were observed; notably, on -site personnel took a few minutes to locate outfall #1. The area associated with the complaint, a bermed area of the parking lot upstream of outfalls #5 and #6, had no standing water at the time of inspection, but the area was covered in what appeared to be moist sediments and/or soils. The inspector noted a stagnant water odor and was unable to identify any potential pollutants in the area.Dumpsters and semi -trucks were in the area, but no apparent leaks were observed. Outfall #6 should be closely monitored for the discharge characteristics required by the permit. Outfall #4 was observed to be over 50% full with sediment/soil. This, and any other outfall with accumulated sediment/soil must be maintained in such a way that any necessary monitoring can be conducted, including qualitative monitoring of suspended solids. Corrective actions must be taken to bring the site into compliance with the permit. The site will be reinspected after 30 days of receipt of this report to evaluate the corrective actions taken in response to the inspection. Failure to comply with the NCG130000 General Permit may result in a Notice of Violation. Page 2 of 3 Permit: NCG130067 Owner - Facility: Blue Ridge Plastics Inspection Date: 08/12/2020 Inspection Type: Compliance Evaluation Reason for Visit: Complaint Stormwater Pollution Prevention Plan Does the site have a Stormwater Pollution Prevention Plan? # Does the Plan include a General Location (USGS) map? # Does the Plan include a "Narrative Description of Practices"? # Does the Plan include a detailed site map including outfall locations and drainage areas? # Does the Plan include a list of significant spills occurring during the past 3 years? # Has the facility evaluated feasible alternatives to current practices? # Does the facility provide all necessary secondary containment? # Does the Plan include a BMP summary? # Does the Plan include a Spill Prevention and Response Plan (SPRP)? # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? # Does the facility provide and document Employee Training? # Does the Plan include a list of Responsible Party(s)? # Is the Plan reviewed and updated annually? # Does the Plan include a Stormwater Facility Inspection Program? Has the Stormwater Pollution Prevention Plan been implemented? Yes No NA NE ■❑❑❑ ■❑❑❑ ■❑❑❑ ■❑❑❑ ❑■❑❑ ❑■❑❑ ❑❑❑■ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑■❑❑ ❑■❑❑ ❑■❑❑ ❑■❑❑ Comment: The facility has a plan from March 2013. An annual SWPPP review was conducted in 2014, but none have been conducted since then. Current practices and personnel must be evaluated in order to update the SWPPP accordinalv. Qualitative Monitoring Yes No NA NE Has the facility conducted its Qualitative Monitoring semi-annually? ❑ 0 ❑ ❑ Comment: The facility has no monitoring records. Analytical Monitoring Yes No NA NE Has the facility conducted its Analytical monitoring? ❑ 0 ❑ ❑ # Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? ❑ ❑ 0 ❑ Comment: The facility has no monitoring records. Permit and Outfalls Yes No NA NE # Is a copy of the Permit and the Certificate of Coverage available at the site? ❑ ❑ ❑ # Were all outfalls observed during the inspection? ❑ ❑ ❑ # If the facility has representative outfall status, is it properly documented by the Division? ❑ ❑ ❑ # Has the facility evaluated all illicit (non stormwater) discharges? ❑ 0 ❑ ❑ Comment: The permit, CoC, and all outfalls were observed during the inspection. The facility has no records of evaluation of illicit dishcarges. Page 3 of 3